Data Center Checklist The purpose of the Data Center Checklist is to allow you to evaluate data center providers on a range of criteria and provide a framework for more informed decisions.
Provider #1 Provider #2 Provider #3
Providers Company Profile
1 2 3
Providers 1 2 3
Environmental Threats continued
Company is publicly held or venture backed
Tidal flooding
Company has audited financials from Big Four auditor
River flooding
Company has multiple data centers
Tsunami
Company has multiple service locations
Blizzards/Hail storms
Company can provide reference accounts competency–designs,engineers engineers and delivers data center Core competency–designs, and delivers data center products and services products and services
Core Power
Company provides a 100% uptime SLA
On-site substation
Company offers modular data center products and ser vices Company offers enterprise-grade “private cloud” Infrastructure as a as a Service Service
Total capacity available at data center (# MW) If yes, is substation dedicated to provider ’s use? Diverse high voltage feeds from utility If yes, what is voltage and capacity (in kV/KVA)?
Company offers standardized data center hardware Company offers software optimized data center infrastructure
Critical Power
Company offers just-in-time data center capacity
# backup generators on-site
Company can meet ultra-high security requirements
Total backup capacity currently available (# MW)
Company has Tier III Design Certification from Uptime Institute
# gallons diesel fuel stored on-site How long at full load? (# minutes)
Data Center Structure
Proximity to diesel fuel filling station ( # miles)
Steel reinforced concrete
Battery backup capacity at load (# minutes)
Square footage
Roll-up generator available on-site
# stories
If yes, does provider own?
Distance from street (# feet) On-site office space
Uninterruptible Conditioned Power
# freight elevators
Concurrently Maintainable Design
# truck/shipping bays
UPS currently available (# MW)
Burn-in/Staging center available
Total UPS available at site (# MW)
Major delivery services available
Diverse UPS manufacturers
Easily accessible from airport/highway
Diverse PDU manufacturers
Secure storage
Power density across entire data center (Watts UPS/SF)
Managed shipping and receiving
Spot densities per square foot (# Watts) Color-coded power cabling
Environmental Threats
Hand-sewn, wax string used
Environmental Threats
Overhead cabling
Earthquakes Tornadoes
Air handling
Hurricanes
Concurrently Maintainable Design
Tidal flooding
# Modular CRAH units
River flooding
Capacity of CRAH units (kw or tons per unit)
Tsunami
High-efficiency raised floor
Blizzards/Hail storms
High-efficiency chilled water system Variable speed plug fans
Environmental Threats Earthquakes
Heat Rejection
Tornadoes
# o compressors/chillers
Hurricanes
# evaporation towers Capacity o chilled water plant (# tons) Bi-directional, welded, valved chilled water loop Continued On Back »
Data Center Checklist (version 1.0) 1
(866) 382-7390
www.io.com
Data Center Checklist The purpose of the Data Center Checklist is to allow you to evaluate data center providers on a range of criteria and provide a framework for more informed decisions.
Providers Efficiency
1 2 3
Providers 1 2 3
Surrounding Area
Thermal Energy Storage (T ES) option available
Located in flood plain
% of time free cooling can be used
Located in flight path Adjacent to highway with hazardous shipping
Compliance Available
Adjacent to railroad tracks
SAS 70 Type II LEED
Water
PCI
Diverse water mains
HIPPA
# gallons water stored on-site
SCIF
Domestic well on-site
Energy Efficiency
Network Carriers
LED lighting
AT&T
Motion activated lighting
AboveNet*
Ultrasonic humidification
AGL
Variable frequency drive chillers
Clearwire
Variable frequency drive pumps
Cox
Variable frequency drive cooling towers
Cogent
Variable frequency drive air handlers
Integra
Sealed cabinets
Qwest*
Insulated roof
Level 3* Paetec
Access Control
Optimum Lightpath
Fenced defensible perimeter
XO
Traffic bollards/car traps
TeliaSonera*
Guard controlled gated entry
tw telecom
24x7xForever on-site guard staff
Verizon Business
Digital video surveillance
*Included in Blended Bandwidth Service
Customer defined access lists Visitor tracking
Network Connectivity
Biometric screening
Free cross-connects
Mantraps
Carrier-neutral
Locking cabinets, cages, suites and modules
On-site Meet-Me-Room
Private access control systems allowed
# diverse fiber entry vaults
24x7xForever customer access without delay
# network providers on-site with gateway access Enterprise-grade blended internet bandwidth w/minimum 10GB