Variant 1a Schematic 3 Single Band Antennas all with Feeder cable
3G X-Pole Antenna
3G X-Pole Antenna
RET
3G X-Pole Antenna
RET
RET 1m Jumper Cables
MHA RET Cable 20m
MHA RET Cable
MHA RET Cable
Splitter RSAA
2m Jumper Cables
RET Cable 2m
RLPA Feeder Cables RET Cable
BTS Room/Shelter
3m Jumper Cables
DC Power & Control for RET 48v or 220v connection
RCUA
RF Unit 1a
RF Unit 1b Double RF Unit
RF Unit 2 Single RF Unit
Flexi BTS System Unit
DC Distribution Box
DDF
2 x E1 Cables DC Power for System & RF Unit
RET Cabling from System Unit to any RET unit must not be longer than 150m Item
Part No.
Qty
1 per sector
KSA:742215
3
1 per antenna
KSA:732317
3
2
KSA:738546
6
Nokia Ultrasite WCDMA MHA Nokia part No.470057A
1 per sector
470057A
3
Clamp for TMA, RSAA and RLPA on mast 45-125mm
2 per MHA + 1 per RSAA
CS7219901
5
1 per site
469757A
1
RLPA - Splitter cable 2m (RCMA) Nokia No. 469789A
1
469789A
1
Lightning protecting device, for RCU-Systems (RLPA) Nokia No. 469833A
1
469833A
1
Control cable 5 Meter (RCCA) Nokia No. 469791A
0
469791A
0
Control cable 20 Meter (RCEA) Nokia No. 469793A
2
469793A
3
Control cable 50 Meter (RCNA) Nokia No. 471003A
2
471003A
3
Control cable 100 Meter (RCHA) Nokia No. 469796A
1
469796A
1
DC Power and Signal Splitter (RSAA) Nokia No. 469797A
1
469797A
1
469834A
10
Kathrein x-pol. +/- 45°, Beamwidth 65°, 18.0 dbi Antenna tilting kit 0 - 10° Antenna Mounting Clamp 2 per antenna
RCUA(CCU) Nokia Part No.: 469757A Version 103
RealTilt Grounding Clamp, RGCA (2 per Cable over 20m then 1 additional for every 20m) Kathrein Remote RET
1 per antenna
KSA:86010025
3
50m per run
ANN:LDF5-50A
300
Click-on hanger(Qty 10), twice for 1 5/8"
ANN:L7CLICK
15
Hardware Kit M10 / 3 Runs / up to 1 5/8" (Qty 10)
ANN:243095-3
5
Compact Angle Adapter M10 (Qty 10)
ANN:243684-M
5
7/16 DIN connector, male for 1 5/8"
ANN:L7TDM-PS
12
Foam Dielectic Cable 1 5/8"
Grounding Kit for 1 5/8"
ANN:SGL7-06B2
18
Jumper cable 1/2", L=1.0 m (7/16 male - 7/16 male)
MHA - Antenna
ANN:F4A-PDMDM-1M
6
Jumper cable 1/2", L=2.0 m (7/16 male - 7/16 male)
Feeder - MHA
ANN:F4A-PDMDM-2M
6
Jumper cable 1/2", L=3.0 m (7/16 90 ° male - 7/16 male)
BTS - Feeder
ANN:F4A-PDMDM-3M
6
Variant 1b Schematic 3 Single Band Antennas all with Feeder cable RET by Daisy Chaining(No Splitter)
3G X-Pole Antenna
3G X-Pole Antenna
3G X-Pole Antenna
RET
RET Cable 5m
RET Cable 20m
1m Jumper Cables
RET Cable 20m
MHA
MHA
MHA
RLPA
2m Jumper Cables
Feeder Cables RET Cable 50m
BTS Room/Shelter
3m Jumper Cables
DC Power & Control for RET 48v or 220v connection
RCUA
RF Unit 1a
RF Unit 1b Double RF Unit
DC Distribution Box
RF Unit 2 Single RF Unit
Flexi BTS System Unit
DDF
DC Power for Node B
2 x E1 Cables
RET Cabling from System Unit to any RET unit must not be longer than 150m Item
Part No.
Qty
1 per sector
KSA:742215
3
1 per antenna
KSA:732317
3
2
KSA:738546
6
Nokia Ultrasite WCDMA MHA Nokia part No.470057A
1 per sector
470057A
3
Clamp for TMA, RSAA and RLPA on mast 45-125mm
2 per MHA + 1 per RSAA
CS7219901
5
1 per site
469757A
1
RLPA - Splitter cable 2m (RCMA) Nokia No. 469789A
1
469789A
1
Lightning protecting device, for RCU-Systems (RLPA) Nokia No. 469833A
1
469833A
1
Control cable 5 Meter (RCCA) Nokia No. 469791A
1
469791A
0
Control cable 20 Meter (RCEA) Nokia No. 469793A
2
469793A
3
Control cable 50 Meter (RCNA) Nokia No. 471003A
1
471003A
3
Control cable 100 Meter (RCHA) Nokia No. 469796A
1
469796A
1
469834A
7
1 per antenna
KSA:86010025
3
50m per run
Kathrein x-pol. +/- 45°, Beamwidth 65°, 18.0 dbi Antenna tilting kit 0 - 10° Antenna Mounting Clamp 2 per antenna
RCUA(CCU) Nokia Part No.: 469757A Version 103
RealTilt Grounding Clamp, RGCA (2 per Cable over 20m then 1 additional for every 20m) Kathrein Remote RET
ANN:LDF5-50A
300
Click-on hanger(Qty 10), twice for 1 5/8"
ANN:L7CLICK
15
Hardware Kit M10 / 3 Runs / up to 1 5/8" (Qty 10)
ANN:243095-3
5
Compact Angle Adapter M10 (Qty 10)
ANN:243684-M
5
7/16 DIN connector, male for 1 5/8"
ANN:L7TDM-PS
12
ANN:SGL7-06B2
18
Foam Dielectic Cable 1 5/8"
Grounding Kit for 1 5/8" Jumper cable 1/2", L=1.0 m (7/16 male - 7/16 male)
MHA - Antenna
ANN:F4A-PDMDM-1M
6
Jumper cable 1/2", L=2.0 m (7/16 male - 7/16 male)
Feeder - MHA
ANN:F4A-PDMDM-2M
6
Jumper cable 1/2", L=3.0 m (7/16 90 ° male - 7/16 male)
BTS - Feeder
ANN:F4A-PDMDM-3M
6
Variant 1c Schematic Outdoor Solution 3 Single Band Antennas all with Feeder cable RET by Daisy Chaining(No Splitter)
3G X-Pole Antenna
3G X-Pole Antenna
3G X-Pole Antenna
RET
RET Cable
RET Cable
1m Jumper Cables
RET Cable
MHA
MHA
MHA
RLPA
2m Jumper Cables
Feeder Cables RET Cable
3m Jumper Cables
RCUA in Weather Proof Box
RCUA
RF Unit 1a
RF Unit 1b Double RF Unit
RF Unit 2 Single RF Unit
Transmission Equipment
System Unit 2 x E1 Cables
Power Module
220v Connection Box
RET Cabling from System Unit to any RET unit must not be longer than 150m Item Kathrein x-pol. +/- 45°, Beamwidth 65°, 18.0 dbi Antenna tilting kit 0 - 10° Antenna Mounting Clamp 2 per antenna Nokia Ultrasite WCDMA MHA Nokia part No.470057A
Part No.
Qty
1 per sector
KSA:742215
3
1 per antenna
KSA:732317
3
2
KSA:738546
6
1 per sector
470057A
3
CS7219901
5
1 per site
469757A
1
RLPA - Splitter cable 2m (RCMA) Nokia No. 469789A
1
469789A
1
Lightning protecting device, for RCU-Systems (RLPA) Nokia No. 469833A
1
469833A
1
Control cable 5 Meter (RCCA) Nokia No. 469791A
1
469791A
0
Control cable 20 Meter (RCEA) Nokia No. 469793A
2
469793A
3
Control cable 50 Meter (RCNA) Nokia No. 471003A
1
471003A
3
Control cable 100 Meter (RCHA) Nokia No. 469796A
1
469796A
1
469834A
7
1 per antenna
KSA:86010025
3
50m per run
Clamp for TMA, RSAA and RLPA on mast 45-125mm RCUA(CCU) Nokia Part No.: 469757A Version 103
per MHA + 1 per RSAA
RealTilt Grounding Clamp, RGCA (2 per Cable over 20m then 1 additional for every 20m) Kathrein Remote RET Foam Dielectic Cable 1 5/8"
ANN:LDF5-50A
300
Click-on hanger(Qty 10), twice for 1 5/8"
ANN:L7CLICK
15
Hardware Kit M10 / 3 Runs / up to 1 5/8" (Qty 10)
ANN:243095-3
5
Compact Angle Adapter M10 (Qty 10)
ANN:243684-M
5
7/16 DIN connector, male for 1 5/8"
ANN:L7TDM-PS
12
ANN:SGL7-06B2
18
Grounding Kit for 1 5/8" Jumper cable 1/2", L=1.0 m (7/16 male - 7/16 male)
MHA - Antenna
ANN:F4A-PDMDM-1M
6
Jumper cable 1/2", L=2.0 m (7/16 male - 7/16 male)
Feeder - MHA
ANN:F4A-PDMDM-2M
6
Jumper cable 1/2", L=3.0 m (7/16 90 ° male - 7/16 male)
BTS - Feeder
ANN:F4A-PDMDM-3M
6
Variant 1d Schematic Sector 1 & 2 using Feeder Cable, Sector 3 using Feeder less Solution
3G X-Pole Antenna
3G X-Pole Antenna
3G X-Pole Antenna
RET
RET
RET
Jumper cable 1m
MHA
RET Cable
MHA RET Cable
RET Cable
Jumper cable 3m RF Unit 2
Splitter RSAA
Single RF Unit
Jumper cable 2m RET Cable 2m
RLPA Lightning protection
Optic Fibre 100m
Feeder Cable RET Cable
BTS Room/Shelter
OVP Box
DC Power Cable max 1.5m
Jumper cable 3m
DC Power max 100 m
DC Power & Control for RET
RCUA
RF Unit 1a
48v or 220v connection
RF Unit 1b DC Power Cable max 1.5m
Double RF Unit
Flexi BTS
DC Distribution Box
OVP Box
Sector 1 & 2 using Feeder Cable Sector 3 using Feeder less Solution
DC Power for System & RF Unit
2 x E1 Cables
DC Cable from System Unit to RF Unit Maximum length 100m DC Over Voltage Protection Box Maximum 1.5m from System and RF unit Optic Fibre Cable from System Unit to RF Unit maximum length 200m RET Cabling from System Unit to any RET unit must not be longer than 150m Item
Part no.
QTY
1 per sector
KSA:742215
3
Antenna tilting kit 0 - 10°
1
KSA:732317
3
Antenna Mounting Clamp 2 per antenna
2
KSA:738546
6
1 per antenna
KSA:86010025
3
I per site
469757A
1
469834A
10
Kathrein x-pol. +/- 45°, Beamwidth 65°, 18.0 dbi
Kathrein Remote RET CCU(RCUA) Nokia Part No.: 469757A Version 103 RealTilt Grounding Clamp, RGCA (2 per Cable over 20m then 1 additional for every 20m) Lightning protecting device, for RCU-Systems (RLPA) Nokia No. 469833A
1
469833A
1
RLPA - Splitter cable 2m (RCMA) Nokia No. 469789A
1
469789A
1
Control cable 5 Meter (RCCA) Nokia No. 469791A
0
469791A
0
Control cable 20 Meter (RCEA) Nokia No. 469793A
2
469793A
2
Control cable 50 Meter (RCNA) Nokia No. 471003A
2
471003A
2
Control cable 100 Meter (RCHA) Nokia No. 469796A
0
469796A
0
DC Power and Signal Splitter (RSAA) Nokia No. 469797A
1
469797A
1
FSEC Flexi System External OVP(including 2m Power Cable)
2
471397A
2
Fibre Optic Cable max length 100m
System - RF Module
471396A
1
DC Power cable 100m
System - RF Module ANN:LDF5-50A
200
Click-on hanger(Qty 10), twice for 1 5/8"
ANN:L7CLICK
10
Hardware Kit M10 / 3 Runs / up to 1 5/8" (Qty 10)
ANN:243095-3
3
Compact Angle Adapter M10 (Qty 10)
ANN:243684-M
3
7/16 DIN connector, male for 1 5/8"
ANN:L7TDM-PS
4
Grounding Kit for 1 5/8"
ANN:SGL7-06B2
12 4
Foam Dielectic Cable 1 5/8"
50m per run
100
Jumper cable 1/2", L=1.0 m (7/16 male - 7/16 male)
MHA - Antenna
ANN:F4A-PDMDM-1M
Jumper cable 1/2", L=2.0 m (7/16 male - 7/16 male)
Feeder - MHA
ANN:F4A-PDMDM-2M
4
Jumper cable 1/2", L=3.0 m (7/16 90 ° male - 7/16 male)
BTS - Feeder
ANN:F4A-PDMDR-3M
4
Jumper cable 1/2", L=3.0 m (7/16 90 ° male - 7/16 male)
RF Unit - Antenna
ANN:F4A-PDMDR-3M
2
DDF
Variant 1e Schematic 3 Triband Antennas with new Feeder cable for 3G and using existing feeder cable for other bands 900 & 1800 using existing feeders, therefore upto 6 feeders per antenna
900
3G
1800
900
1800
3G
900
1800
3G
RET 1m Jumper Cables
MHA RET Cable 20m
MHA RET Cable
MHA RET Cable
Splitter RSAA
2m Jumper Cables
RET Cable 2m
RLPA Feeder Cables RET Cable
BTS Room/Shelter
3m Jumper Cables
DC Power & Control for RET 48v or 220v connection
RCUA
RF Unit 1a
RF Unit 1b Double RF Unit
RF Unit 2 Single RF Unit
Flexi BTS System Unit
DC Distribution Box
DDF
2 x E1 Cables DC Power for Systen & RF Unit
RET Cabling from System Unit to any RET unit must not be longer than 150m Item Kathrein x-pol. +/- 45°, TriBand Antenna tilting kit 0 - 10° Antenna Mounting Clamp 2 per antenna Nokia Ultrasite WCDMA MHA Nokia part No.470057A
Part No.
Qty
1 per sector
KSA:742270
3
1 per antenna
KSA:732317
3
2
KSA:738546
6
1 per sector
470057A
3
per MHA + 1 per RSAA
CS7219901
5
1 per site
469757A
1
RLPA - Splitter cable 2m (RCMA) Nokia No. 469789A
1
469789A
1
Lightning protecting device, for RCU-Systems (RLPA) Nokia No. 469833A
1
469833A
1
Control cable 5 Meter (RCCA) Nokia No. 469791A
0
469791A
0
Control cable 20 Meter (RCEA) Nokia No. 469793A
2
469793A
3
Control cable 50 Meter (RCNA) Nokia No. 471003A
2
471003A
3
Control cable 100 Meter (RCHA) Nokia No. 469796A
1
469796A
1
DC Power and Signal Splitter (RSAA) Nokia No. 469797A
1
469797A
1
469834A
10
1 per antenna
KSA:86010025
3
50m per run
ANN:LDF5-50A
300
Click-on hanger(Qty 10), twice for 1 5/8"
ANN:L7CLICK
15
Hardware Kit M10 / 3 Runs / up to 1 5/8" (Qty 10)
ANN:243095-3
5
Compact Angle Adapter M10 (Qty 10)
ANN:243684-M
5
7/16 DIN connector, male for 1 5/8"
ANN:L7TDM-PS
12
ANN:SGL7-06B2
18
Clamp for TMA, RSAA and RLPA on mast 45-125mm RCUA(CCU) Nokia Part No.: 469757A Version 103
RealTilt Grounding Clamp, RGCA (2 per Cable over 20m then 1 additional for every 20m) Kathrein Remote RET Foam Dielectic Cable 1 5/8"
Grounding Kit for 1 5/8" Jumper cable 1/2", L=1.0 m (7/16 male - 7/16 male)
MHA - Antenna
ANN:F4A-PDMDM-1M
6
Jumper cable 1/2", L=2.0 m (7/16 male - 7/16 male)
Feeder - MHA
ANN:F4A-PDMDM-2M
6
Jumper cable 1/2", L=3.0 m (7/16 90 ° male - 7/16 male)
BTS - Feeder
ANN:F4A-PDMDM-3M
6
Variant 2 Schematic 3 Sector using Triband Antennas using existing Feeder cable and Bias Tee
Tri-Band Antenna
900
Tri-Band Antenna
1800
3G
900
1800
Tri-Band Antenna
3G
900
1800
3G
RET
RET
RET
Jumper cable 1m
Jumper cable 2m
MHA
MHA
MHA
Jumper cable 1m
Triplexer
Triplexer
Triplexer
SBT RET cable
RET cable
RET cable
RET cable
Splitter RSAA
Jumper cable 1m
Existing Feeder Cables
BTS Room/Shelter
BTS Room/Shelter
DC Power & Control for RET
Jumper cable 1m
SBT
Triplexer
Triplexer
Triplexer
Jumper cable 2m
RCUA
3G RF Unit 2
3G RF Unit 1b
3G RF Unit 1a 900
1800
900 3G System Unit 48v or 220v connection
DC Power for System & RF Units
1800
900
1800
2 x E1 Cables DDF
DC Distribution Box
RET Cabling from System Unit to any RET unit must not be longer than 150m
Item Kathrein x-pol. +/- 45°, TriBand Antenna tilting kit 0 - 10°
Part no.
Qty
1 per sector
KSA:742270
6
1 per antenna
KSA:850 10007
6
2
KSA:738546
12
2 per sector
KSA:78210246
Antenna Mounting Clamp 2 per antenna Double Unit, Triple band Triplexer w/ DC stop
6
1 per sector
470057A
3
2 per MHA + 1 per RSAA
CS7219901
7
1 per site
469757A
1
Smart Bias Tee - Splitter cable 5m (RCCA) Nokia No. 469789A
0
469789A
0
Smart Bias Tee BTS side for Nokia RCUA(RSBA) Nokia No. 469869A
1
469869A
1
Smart Bias Tee Ant side for Nokia RCUA(RSMA) Nokia No. 469870A
1
469870A
1
Control cable 20 Meter (RCEA) Nokia No. 469793A
1
469793A
1
Control cable 50 Meter (RCNA) Nokia No. 471003A
1
471003A
1
Control cable 100 Meter (RCHA) Nokia No. 469796A
0
469796A
0
DC Power and Signal Splitter (RSAA) Nokia No. 469797A
1
469797A
1
Nokia Ultrasite WCDMA MHA Nokia part No.470057A Clamp for TMA and RSAA on mast 45-125mm RCUA(CCU) Nokia Part No.: 469757A Version 103
RealTilt Grounding Clamp, RGCA (2 per Cable over 20m then 1 additional for every 20m) Kathrein Remote RET
1 per antenna
469834A
5
KSA:86010025
3
Jumper cable 1/2", L=2.0 m (7/16 90 ° male - 7/16 male)
BTS - Triplexer 2m
ANN:F4A-PDMDR-2M
18
Jumper cable 1/2", L=1.0 m (7/16 male - 7/16 male)
triplexer - feeder 1m
ANN:F4A-PDMDM-1M
6
Jumper cable 1/2", L=1.0 m (7/16 male - 7/16 male)
feeder - triplexer 1m
ANN:F4A-PDMDM-1M
6
Jumper cable 1/2", L=2.0 m (7/16 male - 7/16 male)
Triplexer - Ant
ANN:F4A-PDMDM-2M
12
Jumper cable 1/2", L=1.0 m (7/16 male - 7/16 male)
Triplexer - MHA - Ant
ANN:F4A-PDMDM-1M
12
Variant 3a Schematic Feeder Less Solution Using 3G Antennas, using 3 Single RF Unit
3G X-Pole Antenna
3G X-Pole Antenna
RET cable
RET Jumper Cable 3m
3G X-Pole Antenna
RET
RET RET cable
RET cable Splitter RSAA RET cable 2m
Single RF Unit
Single RF Unit
Lightning protection device
RLPA OVP Box
Single RF Unit
OVP Box
OVP Box
OVP Box max 1.5m from RF unit
Fibre Optic Cable (max 200m)
DC Power (max 100m)
DC Power (max 100m)
RET cable
Optic Fibre max 200m
BTS Room RCUA OVP Box
OVP Box
System Unit
DC Distribution Box
DDF DC Power for System & RF Units
OVP Box
48v or 220v connection
2 x E1 Cables
DC Cable from System Unit to RF Unit Maximum length 100m DC Over Voltage Protection Box Maximum 1.5m from System and RF unit Optic Fibre Cable from System Unit to RF Unit maximum length 200m RET Cabling from System Unit to any RET unit must not be longer than 150m Item
Part no.
QTY
1 per sector
KSA:742215
3
Antenna tilting kit 0 - 10°
1
KSA:732317
3
Antenna Mounting Clamp 2 per antenna
2
KSA:738546
6
1 per antenna
KSA:86010025
3
I per site
469757A
1
469834A
11
Kathrein x-pol. +/- 45°, Beamwidth 65°, 18.0 dbi
Kathrein Remote RET CCU(RCUA) Nokia Part No.: 469757A Version 103 RealTilt Grounding Clamp, RGCA (2 per Cable over 20m then 1 additional for every 20m) Lightning protecting device, for RCU-Systems (RLPA) Nokia No. 469833A
1
469833A
1
RLPA - Splitter cable 2m (RCMA) Nokia No. 469789A
1
469789A
1
Control cable 20 Meter (RCEA) Nokia No. 469793A
3
469793A
3
Control cable 100 Meter (RCHA) Nokia No. 469796A
1
469796A
1
DC Power and Signal Splitter (RSAA) Nokia No. 469797A
1
469797A
1
Fibre Optic Cable max length 100m Jumper cable 1/2", L=3.0 m (7/16 90 ° male - 7/16 male) DC Power cable 100m
3
System - RF Module BTS - Antenna System - RF Module
ANN:F4A-PDMDR-3M
6 300m
Variant 3b Schematic Feeder Less Solution Using 3G Antennas, using 1 double and 1 Single RF Unit
3G X-Pole Antenna
3G X-Pole Antenna
RET cable
RET Jumper Cable 3m
3G X-Pole Antenna
RET
RET RET cable
RET cable Splitter RSAA RET cable 2m
Single RF Unit
Double RF Unit
Lightning protection device
RLPA OVP Box
OVP Box Fibre Optic Cable (max 200m)
OVP Box max 1.5m from RF unit DC Power (max 100m)
DC Power (max 100m)
Optic Fibre max 200m
RET cable
BTS Room RCUA OVP Box
OVP Box
System Unit
DC Distribution Box
DDF DC Power for System & RF Units
48v or 220v connection
2 x E1 Cables
DC Cable from System Unit to RF Unit Maximum length 100m DC Over Voltage Protection Box Maximum 1.5m from System and RF unit Optic Fibre Cable from System Unit to RF Unit maximum length 200m RET Cabling from System Unit to any RET unit must not be longer than 150m Item
Part no.
QTY
1 per sector
KSA:742215
3
Antenna tilting kit 0 - 10°
1
KSA:732317
3
Antenna Mounting Clamp 2 per antenna
2
KSA:738546
6
1 per antenna
KSA:86010025
3
I per site
469757A
1
469834A
11 1
Kathrein x-pol. +/- 45°, Beamwidth 65°, 18.0 dbi
Kathrein Remote RET CCU(RCUA) Nokia Part No.: 469757A Version 103 RealTilt Grounding Clamp, RGCA (2 per Cable over 20m then 1 additional for every 20m) Lightning protecting device, for RCU-Systems (RLPA) Nokia No. 469833A
1
469833A
RLPA - Splitter cable 2m (RCMA) Nokia No. 469789A
1
469789A
1
Control cable 5 Meter (RCCA) Nokia No. 469791A
1
469791A
1
Control cable 20 Meter (RCEA) Nokia No. 469793A
3
469793A
3
Control cable 100 Meter (RCHA) Nokia No. 469796A
1
469796A
1
DC Power and Signal Splitter (RSAA) Nokia No. 469797A
1
469797A
1
Fibre Optic Cable max length 100m Jumper cable 1/2", L=3.0 m (7/16 90 ° male - 7/16 male) DC Power cable 100m
System - RF Module BTS - Antenna System - RF Module
2 ANN:F4A-PDMDR-3M
6 200
Variant 3c Schematic Feeder Less Solution Using 3G Antennas, 1 RF Unit Using Feeder cables
3G X-Pole Antenna
3G X-Pole Antenna
RET cable 20m
RET Jumper Cable
3G X-Pole Antenna
RET
RET RET cable 50m
RET cable 5m
Jumper Cable
Splitter RSAA RET cable 2m
Single RF Unit
Double RF Unit
Lightning protection device
RLPA
MHA
Jumper Cable
OVP Box
OVP Box Fibre Optic Cable (max 100m)
Feeder Cable
OVP Box max 1.5m from RF unit DC Power (max 100m)
DC Power (max 100m)
Optic Fibre max 100m
RET cable 100m
BTS Room OVP Box
RCUA OVP Box
System Unit
DC Distribution Box
DDF DC Power for System & RF Units
48v or 220v connection
2 x E1 Cables
DC Cable from System Unit to RF Unit Maximum length 100m DC Over Voltage Protection Box Maximum 1.5m from System and RF unit Optic Fibre Cable from System Unit to RF Unit maximum length 200m RET Cabling from System Unit to any RET unit must not be longer than 150m Item
Part no.
QTY
1 per sector
KSA:742215
3
Antenna tilting kit 0 - 10°
1
KSA:732317
3
Antenna Mounting Clamp 2 per antenna
2
KSA:738546
6
1 per antenna
KSA:86010025
3
I per site
469757A
1
Kathrein x-pol. +/- 45°, Beamwidth 65°, 18.0 dbi
Kathrein Remote RET CCU(RCUA) Nokia Part No.: 469757A Version 103 Nokia Ultrasite WCDMA MHA Nokia part No.470057A
1 per sector
Clamp for TMA and RSAA/RLPA on mast 45-125mm RealTilt Grounding Clamp, RGCA (2 per Cable over 20m then 1 additional for every 20m) Lightning protecting device, for RCU-Systems (RLPA) Nokia No. 469833A
1
470057A
1
CS7219901
4
469834A
11
469833A
1
RLPA - Splitter cable 2m (RCMA) Nokia No. 469789A
1
469789A
1
Control cable 5 Meter (RCCA) Nokia No. 469791A
1
469791A
1
Control cable 20 Meter (RCEA) Nokia No. 469793A
3
469793A
3
Control cable 100 Meter (RCHA) Nokia No. 469796A
1
469796A
1
DC Power and Signal Splitter (RSAA) Nokia No. 469797A
1
469797A
1
Fibre Optic Cable max length 100m Jumper cable 1/2", L=3.0 m (7/16 90 ° male - 7/16 male) DC Power cable 100m
2
System - RF Module BTS - Antenna System - RF Module
ANN:F4A-PDMDR-3M
6 200
Variant 3d Schematic Feeder Less Solution Using 3G Antennas, 1 RF Unit Using AC/DC Power module and Feeder cables
3G X-Pole Antenna
3G X-Pole Antenna
3G X-Pole Antenna RET cable RET
RET Jumper Cable
RET
RET cable MHA
Splitter
Jumper Cable
RSAA Jumper Cable
RET cable 2m
Single RF Unit
Single RF Unit
Lightning protection device
RLPA OVP Box
Feeder Cable 15m
OVP Box
Jumper Cable Single RF Unit
Fibre Optic Cable (max 200m) DC Power (max 100m)
DC Power (max 100m)
RET cable
BTS Room RCUA OVP Box
OVP Box
System Unit
DC Distribution Box
DDF DC Power for System & RF Units
OVP Box max 1.5m from System Unit
Power Supply Module
Optic Fibre max 200m
48v or 220v connection
2 x E1 Cables
DC Cable from System Unit to RF Unit Maximum length 100m DC Over Voltage Protection Box Maximum 1.5m from System and RF unit Optic Fibre Cable from System Unit to RF Unit maximum length 200m RET Cabling from System Unit to any RET unit must not be longer than 150m Item
Part no.
QTY
1 per sector
KSA:742215
3
Antenna tilting kit 0 - 10°
1
KSA:732317
3
Antenna Mounting Clamp 2 per antenna
2
KSA:738546
6
1 per antenna
KSA:86010025
3
I per site
469757A
1
469834A
11
Kathrein x-pol. +/- 45°, Beamwidth 65°, 18.0 dbi
Kathrein Remote RET CCU(RCUA) Nokia Part No.: 469757A Version 103 RealTilt Grounding Clamp, RGCA (2 per Cable over 20m then 1 additional for every 20m) Lightning protecting device, for RCU-Systems (RLPA) Nokia No. 469833A
1
469833A
1
RLPA - Splitter cable 2m (RCMA) Nokia No. 469789A
1
469789A
1
Control cable 20 Meter (RCEA) Nokia No. 469793A
3
469793A
3
Control cable 100 Meter (RCHA) Nokia No. 469796A
1
469796A
1
DC Power and Signal Splitter (RSAA) Nokia No. 469797A
1
469797A
1
Fibre Optic Cable max length 100m Jumper cable 1/2", L=3.0 m (7/16 90 ° male - 7/16 male) DC Power cable 100m
System - RF Module BTS - Antenna System - RF Module
3 ANN:F4A-PDMDR-3M
6 300m
220v Distribution Box