Conveyor Control Using Allen Bradley PLC PLC Type 1761 MicroLogix 1000, Name Input / Output PLC : INPUT PLC : I:0/0 ; Infrared Sensor I:0/1 ; Push Button Start (Normally Open Contact) I:0/2 ; Push Button Stop (Normally Closed Contact) --- Link : normally open normally closed contact OUTPUT PLC : O:0/0 ; Empty Lightbox O:0/1 ; Start-Stop on Inverter PLC Programming for Conveyor Control using Allen Bradley PLC
Please Download Programming for RSLogix Micro Starter Lite : Conveyor Control Reading Ladder PLC Programming for Conveyor Control using Allen Bradley PLC :
1. Conveyor Start a.If I:0/1 = ON AND I:0/2 = ON Then B3:0/0 = ON (Hold ON) b.If B3:0/0 = ON AND I:0/0 = OFF Then B3:0/1 = ON c.If B3:0/1 = ON Then O:0/1 = ON 2. Conveyor Stop a.If I:0/2 = OFF Then B3:0/0 = OFF b.If B3:0/0 = OFF Then B3:0/1 = OFF c.If B3:0/0 = ON AND I:0/0 = ON Then B3:0/1 = OFF d.If B3:0/1 = OFF Then O:0/1 = OFF 3. Empty Lightbox = ON
a.If B3:0/0 = ON AND I:0/0 = OFF Then T4:0 activated (active for 10 seconds) b.If T4:0/DN = ON Then O:0/0 = ON
System requirements: 1. A plc is used to start and stop the motors of a segmented conveyor belt, this allows only belt sections carrying a copper plate to move. 2. The system have three segmented conveyor belts, each segment runs by a motor. 3. A proximity switch located at the end of each segment to detect the position of the plate. 4. The first conveyor segment is always on. 5. The second conveyor segment turns on when the proximity switch in the first segment detects the plate. 6. when the proximity switch at the second conveyor detects the plate, the third segment conveyor turns ON. 7. the second conveyor is stopped, when the plate is out of detection range of the second proximity switch, after 20 seconds. 8. the third conveyor is stopped after 20 seconds, when the proximity swtch located at the segment doesn’t detect the plate.