Product Change Notice Huawei PCN SRAN-2012XXXX (EOM Notice on DBS3900(AC) APM30H&TMC11H&IBBS200D&T Ver.B cabinets)
0. Change History
2012-08-26
Rev: 01
2012-12-26
Rev: 02
Yongpeng
Ver.D1 and Ver.D2 have been amalgamated into Ver.D, Ver.D Cabinet Configuration is the same as Ver.D2
Zhangli
1. Add the Change History table 2013-02-05
Rev: 03
2.Delete the last order date of spare parts
Zhangli
3.Update some spare parts coding
1. Abstract The Ver.B cabinets and internal parts will will be in the end of marketing (EOM).
The DBS3900 (AC)
Ver.D cabinets will be sold to replace the Ver.B cabinets. This PCN is intended for customers using Huawei DBS3900 (AC) Ver.B cabinets. The last date for purchase of the Ver.B cabinets is June 30, 2013 and the last date for supply of Ver.B cabinet is December 31, 2013.
2. Supplier Information Huawei Technologies. Co., Ltd.
Confidential
Page 1 of 12
Product Change Notice
3. Basic Information PCN No.
SRAN-2012XXXX
PCN Version
Rev: 03
Change Category
B Official release of
Release
the PCN GA
Implementation
Milestone
of
No order accepted for Ver.B cabinet No delivery after EOP
Production
End of Service
new
cabinets
End of Marketing
End
of
for
December 31, 2012
June 30, 2013
December 31, 2013, from which no old cabinets will
Ver.B be delivered (the delivery time in new sales contracts
cabinet No
Feb 5, 2013
should not be later than this date) service
provided after EOS
Subject to the specific contract
4. Involved Systems and Products There is one type for APM30H/TMC11H/IBBS200D/T in Ver.D cabinets. Customer can use Ver.D to replace the current version of cabinets. Main System
Subsystem
Hardware
Software
Firmware
Plug-in
DBS3900 (AC) Ver.D
Cabinets and internal parts
Yes
Yes
No
No
(note1)
Note 1:To replace Ver.B cabinets with the same maximum configuration of 6 RRU, the Ver.D cabinets can work normal with the same BTS software version. But if the enhanced configuration of Ver.D need be used like supporting 12 RRU, the BTS software version should be upgraded.
5. Correlated Change N/A
Confidential
Page 2 of 12
Product Change Notice
6. BOM Code Change New
BOM
Code
Old
Board Name
BOM
Code
Board Name
Complete Replacement
Ver.D
APM30H cabinet
Ver.B
APM30H cabinet
Yes
Ver.D
IBBS200D cabinet
Ver.B
IBBS200D cabinet
Yes
Ver.D
IBBS200T cabinet
Ver.B
IBBS200T cabinet
Yes
Ver.D
TMC11H cabinet
Ver.B
TMC11H cabinet
Yes
01071382
EPU05A-03
02400460
EPS 01B
No
01071384
EPU05A-05
02400462
EPS 01D
No
02310HBJ
R4850G
02130608
EPW30-48A
No
02310LYP
PMU 11A
02317275
PMU 01B
No
02120734
FAN 02D
02120559
FAN 02A
No
03021VGY
CMUEA
03020NXE
CMUA
No
02120732
DCDU-12C
02120479
DCDU-03C
No
21161105
TEC module
21161003
TEC module
No
The external fan of Heat 32030092
Exchanger APM30H/TMC11H
of
The external fan of Heat 32030077
Exchanger
97051086
APM30H/TMC11H
Ver.D cabinet
of
No
Ver.B cabinet
7. Categorization Basis (1) Ver.B cabinets and parts will be in the EOM and be replaced by Ver.D.. (2) The new release has all the functions of current version and better performance. The Ver.B can support 6 RRU(2*40W) at maximum. The Ver.D supports 6 RRU(2*60W) at maximum without BTS software upgrading. The Ver.D also supports 12 RRU(2*60W) with one DCDU-12B added at 1U user space in APM30H after BTS software is upgraded. The Ver.D cabinet supports two BBU in one APM30H also.
8. Software version for the enhanced configuration of Ver.D.
The enhanced configuration of Ver.D 1 2 3
Indoor Cabinet — FMUEA board
Network element
Software version
CME
V200R011C00SPC250+CP2501
BSC
V900R013C00SPC582
MBTS
V100R004C00SPC190
CME
V200R012C00SPC220+CP2201
、
Outdoor Cabinet — CMUEA board
SRAN6.0
、
support 5pcs PSU
、
Confidential
Page 3 of 12
Product Change Notice
SRAN8.0
BSC
V900R014C00SPC520
MBTS
V100R007C00SPC240
CME
ALL
BSC
ALL
MBTS
ALL
9. Change Description (A) The change of the Ver. D cabinets
The changed parts include the Heat Exchanger, fan tray, TEC and DCDU.etc. The external size and installing of new cabinet are the same as old one.
The Ver.D cabinet improves the capacity of power supply, heat dissipation and cabling. It has all the functions of the Ver.B cabinet and better performance instead. The Ver.D cabinet supports two BBU, The Cooling capability from 700W to 1500W in one APM30H or TMC11H .
The cabinet version info can be acquired by OMC remotely or be seen on the nameplate in the cabinet on site. (B) The major changed parts from Ver.B to Ver.D cabinet
Confidential
Page 4 of 12
Product Change Notice
9.1 The change of Heat Exchanger and interal Fan tray in APM30H and TMC11H (A) The air vent areas are enlarged for the i nternal heat exchanger on the door of APM30H/TMC11H Ver.D cabinet. But the external size of the door keeps the same as the Ver.B still. The external fan type and Heat exchanger core are changed from Ver.B cabinet to Ver.D cabinet. The external fan type is the same between APM30H/TMC11H Ver.D.
(B) The fan tray is changed from FAN 02A to FAN 02D. The air outlet position is changed from top to bottom. The HPMI board is cancelled to make the monitor cable connection simple on the new fan tray. “TEM_BAT1 ” The “GATE” and interfaces are supported directly in PMU11A module for APM30H.
The other internal reserved interfaces are cancelled to avoid wrong connection.
(C) The heat dissipation capacity of APM30H/TMC11H is improved.
Heat dissipation
Cabinet version APM30H/TMC11H Ver.B
APM30H/TMC11H Ver.D
700W <=700W >700W and <=1500W
Confidential
Acoustic noise ETS 300 753, Rural area, Class 4.1E(6.1bels@25℃, 6.7bels@45 ℃) ETS 300 753, Rural area, Class 4.1E(6.1bels@25℃, 6.7bels@45 ℃) ETS 300 753, Urban area, Class
Page 5 of 12
Product Change Notice
4.1E(6.6bels@25℃, 7.6bels@45 ℃)
9.2 The change of AC/DC power system inside in APM30H (A) The layout and name change. When Ver.D APM30H cabinet replace the Ver.B cabinet, the EPU05A-03 (220V AC) or EPU05A-05 (110V AC) replace the EPS 01B (220V AC) or EPS 01D (110V AC) of embedded power system. The height is 1U only for PSU and PMU in new version cabinet. The old PSU and PMU are 2U high. upgraded the highest efficiency from 91% to 96%. APM30H Ver.D supports 5 PSU at maximum. Three PSU can be managed in Ver.D cabinet like Ver.B cabinet with the same BTS software. The BTS software need be upgraded if four or five PSU need be used in Ver.D cabinet to support 12 RRU.
(B) The change of PSU version
name
Power capacity
The highest efficiency
Ver.B
EPW30-48A
1600W/PCS
91%
Ver.D
R4850G
3000W/PCS
96%
Ver.B
PMU 01B
--
--
Ver.D
PMU 11A
--
--
Remark: The height is 1U only for PSU and PMU in new version cabinet. The old PSU and PMU are 2U high. (C) The change of AC power distribution:
Confidential
Page 6 of 12
Product Change Notice
AC Input Breaker
3×16A(1P MCB)---PSU
AC Output Breaker
1×16A(2P MCB)---Heater/Socket
AC Input Breaker
2×40A+1×25A (1P MCB)---PSU
AC Output Breaker
1×16A (2P MCB)---Heater/Socket
220V input,EPS 01B AC Input Breaker
1×40A(2P MCB)---PSU
AC Output Breaker
220V input,EPU05A-03 AC Input Breaker
1×100A(2P MCB)---PSU
AC Output Breaker
1×16A(1P MCB)---Heater
1×16A (1P MCB)---Heater
1×16A(1P MCB)---Socket
1×16A (1P MCB)---Socket
110V dual phase input ,EPS 01D
110V dual phase input ,EPU05A-05
(D) The change of DC power distribution
LLVD
LLVD
6×20A(1P MCB)---RRU
BLVD
6×30A(FUSE)---RRU
1×125A(1P MCB)---RFC
2×15A(FUSE)---BBU
BLVD
1×15A(FUSE)---FAN
2×30A(FUSE)---BBU
4×5A(FUSE)---TM
1×30A(FUSE)---FAN
1×25A (1P MCB )---TMC
4×30A(FUSE)---TM
1×15A(FUSE)---TEC
1×30A (FUSE )---TMC
1×100A (1P MCB)---BATT
1×30A(FUSE)---IBBS
1×125A (2P MCB)---BATT
Remark: The spare fuses are changed from “2*5A+6*15A” to “5*5A+3*30A” in APM30H cabinet.
(E) The change of AC power interface from customer
Confidential
Page 7 of 12
Product Change Notice
Only when the Ver.D cabinet has more powerful RF configurations than Ver.B, the power interface should be changed. Input voltage
Cabinet
RFU
version
configuration
three
and AC power interface from customer
Ver.B, 220Vac
types
2
6 x RRU(2*40W)
25A/3P (2.5 mm cables),minimum.
6 x RRU(2*60W)
25A/3P (4 mm cables),minimum.
12 RRU(2*60W)
40A/3P (6 mm cables) ,minimum.
6 x RRU(2*40W)
50A/2P, (6 mm cables)
6 x RRU(2*60W)
63A/2P (16 mm cables)
12 RRU(2*60W)
100A/2P (16 mm LSZH cables)
Ver.D
phase
2
Ver.D
220Vac
single
phase Or
Ver.B,
2
2
minimum.
,
Ver.D 110Vac
dual-live-wire
2
minimum.
,
Ver.D
2
minimum.
,
9.3 The change of cable outlet in APM30H and TMC11H The power cable diameter is enlarged and the cable outlet is adjusted also on the bottom of cabinet. The new outdoor type of cable bag has double space for cable and much shorter installing time than the current version.
9.4 The change of DCDU in TMC11H (A) The layout and name change.
(B) The enhance of DC distribution Version Ver.B
Confidential
Distribution capacity 7x12A(1P MCB)+2x6A(1P MCB)
Page 8 of 12
Product Change Notice
Ver.D
10 x 30A (fuse)
Remark: There are three spare fuses of 30A in the right of new DCDU. (C) The change of the input connection to support the parallel connection of 2 route 16mm2 cables.
(D) The change of output connectors to benefit installing. Plugging or unplugging the connector can power on or off the load of the new version DCDU.
(E) For new version DCDU, No supply the DC SPD ALARM Connector.
9.5 The change of fan tray in IBBS200D There is only one fan in IBBS200D Ver.D to save power consumption. The Ver.B has two fans. The monitor board is changed from CMUA of Ver.B cabinet to CMUEA of Ver.D cabinet. But the external cable interfaces keeps the same.
9.6 The change of TEC module in IBBS200T The Thermoelectric Cooler module is changed in IBBS200T Ver.D. The installing interface keeps the same for the new TEC module. The monitor board is changed from CMUA of Ver.B cabinet to CMUEA of Ver.D cabinet. But the external cable interfaces keeps the same.
Confidential
Page 9 of 12
Product Change Notice
9.7 The change of IBBS200D/IBBS200T PDU The power distribution unit is improved in Ver.D to support more powerful equipments with more discharge current.
9.8 The change of cable outlet in IBBS200D/IBBS200T The power cable diameter is enlarged and the cable outlet is adjusted also on the bottom of cabinet. The new outdoor type of cable bag has double space for cable and much shorter installing time than the current version.
9.9 The change of all cabinets package The cabinet external packages are changed from wood to paper in order to be more environments friendly.
Confidential
Page 10 of 12
Product Change Notice
10. Impact of Change Security
Fire
Service
Communication
None
None
Yes
None
For Ver.D cabinet is configured four or five PSU to support more than 6 RRU, the BTS software need be upgraded and it interrupt service within 5 minutes No service is impacted if there are three PSU are used in Ver.D at maximum to support 6 RRU Maintenance
Reliability
Power Consumption
Traffic
Yes.
None
Yes
Yes.
Some spare parts of the
Ver.D
Ver.
powerful RRU with some increased much higher traffic.
D
cabinet
are
cabinet
support
different from the Ver. B
power consumption.
cabinet.
No
Therefore,
a
more
power
much
more
consumption
is
certain quantity of spare
increased for Ver.D cabinet using the
parts
same type and number of BBU and
of
the
Ver.
B
cabinet must be reserved
Ver.D BTS supports
RRU modules as Ver.B cabinet.
for future use.
11. Involved Documents The changes will affect the 《DBS3900 Product description》 and 《DBS3900 User Manual》.
12. Appendixes None
Confidential
Page 11 of 12
Product Change Notice
13. Remarks If you have any questions, contact Huawei local sales representatives or technical support personnel for assistance.
Confidential
Page 12 of 12