FIRE ALARM SYSTEM TRAINER MCT‐CL221
This Fire Alarm System Trainer is specially developed to teach and train students to know the function and operation of a of a fire alarm system. The purpose of a of a fire alarm system is to give warning when it detects any sign of a of a possible fire outbreak in an enclosed environment. The equipment consists of a of a Control Panel, Siren, Bell, Smoke Detector, Heat Detector, Glass Break, Strobe Light, Emergency Stop and Duty Pump. Its design is based on panel system. Each panel is silk screened with symbols or block diagram. The control panel comes in 2 to 30 zones as standard but more zones capacity can be made to meet with the customer's specifications. It accepts a wide variety of detectors of detectors and sounding devices with line supervision output for the zone and alarm bell circuits. SPECIFICATIONS Control Panel
The panel is in modular design utilizing highly integrated modules to provide improved versatility and easy of maintenance and replacement. Connections between modules are established with highly reliable computer ribbon cables and removable sockets.
MAIN SUPPLY
LINK FOR CONTROL PANEL
Dimension : 100 x 298 x 50mm
Dimension : 200 x 298 x 50mm
Input / output : 240 VAC
Input Voltage : 240 VAC
VOLTAGE SUPPLY
GLASS BREAK
Dimension : 200 x 298 x 50mm
Dimension : 200 x 298 x 50mm
Input : 240 VAC
Operating Voltage : 24 VDC
Output : 240 VAC / 24 VDC
Contact : Normally Open
EMERGENCY STOP
Dimension : 100 x 298 x 50mm
SECONDARY PUMP SIMULATION
Operating Voltage : 24 VDC
Dimension : 100 x 298 x 50mm
Contact : Normally Close
Operating Voltage : 24 VDC
FIRE ALARM SYSTEM TRAINER MCT‐CL221 HEAT DETECTOR
BELL
Dimension : 100 x 298 x 50mm
Dimension : 200 x 298 x 50mm
Operating Voltage : 24 VDC
Operating Voltage : 24 VDC
Contact : Normally Open
SMOKE DETECTOR
STROKE LIGHT
Dimension : 200 x 298 x 50mm
Dimension : 100 x 298 x 50mm
Operating Voltage : 24 VDC
Operating Voltage : 24 VDC
ZONE DIAGRAM
DUTY PUMP
Dimension : 200 x 298 x 50mm
Dimension : 100 x 298 x 50mm
Operating Voltage : 24 VDC
Operating Voltage : 240 VAC 24 VDC
GAS DETECTOR
WATER DETECTOR
Dimension : 200 x 298 x 50mm
Dimension : 100 x 298 x 50mm
Operating Voltage : 24 VDC
Operating Voltage : 24 VDC
ELECTORMECHANICAL SIREN
STROBE LIGHT
Dimension : 100 x 298 x 50mm
Dimension : 100 x 298 x 50mm
Operating Voltage : 24 VDC
Operating Voltage : 24 VDC
DUTY PUMP CONTROLLER
Dimension : 160 x 120 x 80mm Operating Voltage : 240VAC Description : To run & stop duty pump
FIRE ALARM SYSTEM TRAINER MCT‐CL221 Conventional Fire Alarm System
Estimated lab time: 40 hours 12 Work Orders 1 Sketch and Wiring (1): Draw a schematic diagram, and wire a project involving four components at a given location. 2 Sketch and Wiring (2): Redo the circuit of Work Order 1 with the components at a different location. 4 Sketch, Wiring, and Programming (1)1: Draw the schematic diagram of a circuit consisting of a break glass, heat detector. 5 Sketch, Wiring, and Programming (2): Draw the schematic diagram of a circuit consisting of a smoke detector, break glass, siren, and strobe light. 6 Sketch, Wiring, and Programming (3): Draw the schematic diagram of a circuit consisting of a pull station in one zone and a break glass station in a second zone to trigger a siren in a third zone. 7 Sketch, Wiring, and Programming (4): Draw the schematic diagram of a circuit consisting of two pull stations and a heat detector in a detection zone, a third pull station in a second detection zone to trigger a siren, and a strobe light in a signaling zone. 8 Sketch, Wiring, and Programming (5): Draw the schematic diagram of a circuit consisting of a smoke detector in detection zone 1, a strobe light in detection zone 2, a pull station in signaling zone 1, and a strobe light in signaling zone 2. 9 Sketch, Wiring, and Programming (6): Draw the schematic diagram of a circuit consisting of a smoke detector, three glass break stations, a horn, and strobe light.Locate the components according to the plan supplied. 10 WO 10 Sketch, Wiring, and Programming (7): Draw the schematic diagram of a circuit consisting of a heat detector, three glass break stations, a siren horn, and a strobe light. Locate the components according to the plan supplied. 11 Sketch, Wiring, and Programming (8): Draw the schematic diagram of a circuit consisting of the same components as in Work Order 10 but with a different location. 12 Sketch, Wiring, and Programming (9): Draw a schematic diagram consisting of two pull stations, a heat detector, a siren horn, and a strobe light. Use a third pull station as a tamper switch to simulate a supervisory signal into the control panel.
COURSEWARE AND ACCESSORIES
Experiments Manual
Connecting Leads Set