Fill with PUR Filler Foam without joints ETICS Plinth and Underground Insulation Board, bonded with ETICS Multiflex ETICS Basecoat + Finishing Coat in system build-up double protection coat using ETICS Multiflex foundation wall protection foil existing water proofing* capillary-breaking, water draining layer, e.g. gravel
≥ 220
*according to DIN 18195
Date: 2009-07-01
Schematic view
Vertical section
10
Passive house detail 0.1.2 Design of plinth connected to soil
bonding interior plaster
ETICS Insulation Board ETICS Basecoat + Finishing Coat in system build-up
brickwork ≥ 260
175
10 screed on isolation layer/ steam barrier thermal insulation
existing water proofing* 300
existing water proofing*
50
basement ceiling
250
double protection coat using ETICS Multiflex insulation stone mortar bed
200
ETICS Plinth and Underground Insulation Board, bonded with ETICS Multiflex foundation wall protection foil 200
unheated basement
*according to DIN 18195
Date: 2009-07-01
Schematic view
Vertical section
Passive house detail 0.1.3 Skirting design with connection to base plate
≥ 260
175
10
bonding interior plaster ETICS Insulation Board ETICS Basecoat + Finishing Coat in system build-up
brickwork screed on isolation layer/ steam barrier thermal insulation
existing water proofing* 300
existing water proofing* base plate
50
compensation layer
250
double protection coat using ETICS Multiflex
200
foundation wall protection foil
insulation stone mortar bed
drainage
fillet ETICS Plinth and Underground Insulation Board, bonded with ETICS Multiflex
*according to DIN 18195
Date: 2009-07-01
Schematic view
Vertical section
Passive house detail
0.2
Connection to balcony exit sill
ETICS Sealing Tape balcony exit sill
ETICS Sealing Tape airtight window connection foil ETICS Basecoat + Finishing Coat in system build-up supporting console double protection coat using ETICS Multiflex foundation wall protection foil ETICS Plinth and Underground Insulation Board, bonded with ETICS Multiflex
Date: 2009-07-01
≥ 260
Schematic view
175
Vertical section
Passive house detail 0.3.1 System connection to windows flush with facade
ETICS Window Sill
≥30
ETICS Window Joint Profile, Special+
airtight window connection foil
≥ 260
ETICS Basecoat + Finishing Coat in system build-up
175
10
brickwork
ETICS Insulation Board
interior plaster
bonding
Date: 2009-07-01
Schematic view
Vertical section
Passive house detail 0.3.2 System connection to semi-attached windows