This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. indicates that death or severe personal injury
indicates that death or severe personal injury
result if proper precautions are not taken.
result if proper precautions are not taken.
indicates that minor personal injury can result if proper precautions are not taken.
indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. The product/system described in this documentation may be operated only by for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Note the following: Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions.
Siemens AG Industry Sector Postfach 48 48 90026 NÜRNBERG GERMANY
Ⓟ 12/2012 Technical data subject to change
Copyright © Siemens AG 2012. All rights reserved
2.1
General information.......................................................................................................................7
2.2
Solved problems in Update 3........................................................................................................8
2.3
Solved problems in Update 2......................................................................................................12
2.4
Solved problems in Update 1......................................................................................................15
WinCC flexible 2008 SP3 Update 3 Readme, 11/2012,
3
This update is valid for the following WinCC flexible 2008 SP3 editions: ● WinCC flexible 2008 SP3 Compact / Standard / Advanced ● WinCC flexible 2008 SP3 ASIA Standard / Advanced ● WinCC flexible 2008 SP3 China ● WinCC flexible 2008 SP3 Runtime
To install the update, please follow the instructions in the chapter "Installation".
WinCC flexible 2008 SP3 Update 3 Readme, 11/2012,
5
General information that could not be included in the manual or Online Help for WinCC flexible 2008 SP3.
Chinese font is now supported in data type "String" for connections to SIMATIC S7 300/400. Activate the "Chinese (VR)" option in the Engineering System. The CP936 code page is now used instead of the ASCII code page. The option is available for the following devices: ● MP 377 ● WinCC flexible Runtime
WinCC flexible 2008 SP3 Update 3 Readme, 11/2012,
7
Solved problems 2.2 Solved problems in Update 3
A Pack&Go file that you create on a 64-bit system may not be fully functional on a 32-bit system. A Pack&Go file that you create on a 32-bit system may not be fully functional on a 64-bit system.
If you are using SIMATIC Manager to transfer a project to an HMI device you cannot edit certain transfer settings.
If several connections to the PLC are active, you cannot determine which of the configured connections is used by the tag during runtime.
The tag dialog displays hardware components that do not contain tags that can be used for HMI devices.
Compilation of a project with formatted text and tags with invalid reference fails with a nonspecific error message.
If you assign the "SetBit" system function to the
key on the OP 77A HMI device, the following error message may be output during compilation of the project: "object xxxx is marked to be activated but does not exist“.
The tab order differs, depending on whether or not the graphic objects are grouped..
Incorrect processing of the tab order in screens with faceplates.
Conversion of a project that contains invalid tag interconnections will fail.
System function "ActivateClearingScreen" is not available on the MP 377 15“ Touch daylight readable HMI device.
After you configure graphic objects in the template and then change the user interface language, the configured objects are no longer visible. This behavior occurs only in Windows 7.
8
WinCC flexible 2008 SP3 Update 3 Readme, 11/2012,
Solved problems 2.2 Solved problems in Update 3
An incorrect message informing you that code page CP939 is being used is output during generation of a project with code page CP936.
Certain printers may output an incorrect layout when printing the report. Devices affected: ● PC Runtime
Pressing the key on the on-screen keyboard may trigger an unwanted input. Devices affected: ● PC Runtime ● Windows CE HMI devices
A click in the space next to a sequencer object in ProAgent followed by an activation of system function "SequencerScreenActivateStep" may cause problems in the connected S7 PLC. Devices affected: ● PC Runtime ● Windows CE HMI devices
Exceeding the number of rows that can be displayed in the Motion View may lead to problems when you select a row. Devices affected: ● PC Runtime ● Windows CE HMI devices
Due to different time characteristics on certain systems, random problems may occur during archiving at the start of Runtime or at the call of system function "OpenAllArchives". Devices affected: ● PC Runtime ● Windows CE HMI devices
Setup of a canceled connection may fail on specific devices that are connected by means of MODBUS RTU. Moreover, incorrect values are possibly transmitted to the PLC from the panel if data types "Double" or "Float" are used.
WinCC flexible 2008 SP3 Update 3 Readme, 11/2012,
9
Solved problems 2.2 Solved problems in Update 3
Devices affected: ● KTP1000 Basic color DP
Incorrect data is possibly exchanged between the PLC and the panel if data types Double or Float are used. Devices affected: ● KTP600 Basic color DP ● KTP1000 Basic color DP ● OP 77A ● TP 177A
If you are using an S7 200 PLC, a tag of the type "String" may be appended by additional characters at random intervals. Devices affected: ● Basic Panels ● OP 73 ● OP 77A ● TP 177A
During the setup of a serial connection, a change of the parity at the serial interface my prevent setup of the connection. Devices affected: ● KTP1000 Basic color DP
Read errors may develop for specific data types in connections with OMRON PLCs. Devices affected: ● KTP600 Basic color DP ● KTP1000 Basic color DP ● OP 77A ● TP 177A
Basic Panels may not properly recognize the "Press" and "Release" events assigned to a button during configuration of system functions.
10
WinCC flexible 2008 SP3 Update 3 Readme, 11/2012,
Solved problems 2.2 Solved problems in Update 3
Unreliable behavior of transponder connections may develop on certain Mobile Panel 277 IWLAN devices. Update the OS of the Mobile Panels and transfer your project once again.
WinCC flexible 2008 SP3 Update 3 Readme, 11/2012,
11
Solved problems 2.3 Solved problems in Update 2
Sections of the Properties window are not displayed for devices of the /Sinumerik option.
Tag names contained in the message texts are incorrectly linked during rewiring.
If you select a navigation bar, the properties are not displayed in the Properties window.
The selection of a text entry list can take several seconds for large text lists.
A STEP 7 project with a WinCC flexible component is archived in the root directory of a drive with the Simatic Manager. Result: The temporary directory "TMPSTUFF_HMIES_0001" is not deleted.
Empty fields in the export file cause the column headers to be without column heading.
If you have configured a tag at a switch, duplicate entries appear in the audit trail.
If a project containing ProAgent components and a large number of messages is opened, synchronization takes a long time. If you set the key "" in the HmiES.exe.config file, the initial synchronization is skipped. To start synchronization again, select "Project> Rebuild All".
Select multiple tags in the symbol table and drag the tags to a screen using drag-and-drop. Multiple selection does not work reliably. Sometimes objects from an earlier mu ltiple selection are inserted in the screen.
You convert a project created with an earlier version of SIMOTION SCOUT to the current version. When you open it, you specify whether the converted project should be opened with or without write protection. The fix prevents the WinCC flexible components against editing when the read-only project is opened.
12
WinCC flexible 2008 SP3 Update 3 Readme, 11/2012,
Solved problems 2.3 Solved problems in Update 2
Projects created with an earlier version of SIMOTION SCOUT are converted to the latest version of SIMOTION SCOUT. If you convert the project directly after installing WinCC flexible and open it as read-only, sometimes no HMI nodes are displayed in the project tree.
If WinCC flexible integration is enabled in SIMOTION SCOUT, you can activate the "Any HMI object" filter for the search. The filter was also offered when the WinCC flexible integration had been disabled in SIMOTION SCOUT. Searching with this filter makes SIMOTION SCOUT no longer operable.
Opening converted projects with write protection and non-converted projects results in the following behavior: You can also insert read-only HMI projects in the project tree.
If there is an attempt to write an invalid date to the controller, sometimes no error message is displayed.
Tags that use address or DB multiplexing, show no values on the HMI device.
If you import and save recipe records from CPU to the recipe view, the previous values can be displayed after the saving. Devices affected: ● Window CE HMI devices ● PC Runtime
You use the Arial font in a project. If you use the on-screen keyboard on an HMI device, the font may not be displayed the next time you start Runtime. Devices affected: ● Window CE HMI devices
You use Audit in your project. It can happen that the user can no longer log off if the archive cannot be accessed. Devices affected: ● Window CE HMI devices ● PC Runtime
WinCC flexible 2008 SP3 Update 3 Readme, 11/2012,
13
Solved problems 2.3 Solved problems in Update 2
If you switch off the HMI device without shutting down Runtime, the last archive entries might not be written. This behavior has been improved, but it is still recommended to shut down Runtime before switching off the HMI device. Devices affected: ● Window CE HMI devices
If you use a VNC solution from a third party, a Sm@rtService license may be required.
14
WinCC flexible 2008 SP3 Update 3 Readme, 11/2012,
Solved problems 2.4 Solved problems in Update 1
We have been recently informed about vulnerabilities in WinCC flexible. These claims have been thoroughly investigated by our specialists and the security loopholes in WinCC flexible have been closed. Our internal investigation also uncovered additional security loo pholes in Sm@rtService (web pages). Update 1 for WinCC flexible 2008 SP3 closes these security loopholes as well.
WinCC flexible 2008 SP3 Update 3 Readme, 11/2012,
15
This update requires one of the following WinCC flexible installations: ● WinCC flexible 2008 SP3 Compact / Standard / Advanced ● WinCC flexible 2008 SP3 ASIA Standard / Advanced ● WinCC flexible 2008 SP3 China ● WinCC flexible 2008 SP3 Runtime Install the update on your configuration PC and Runtime PC.
To install the update, proceed as follows: 1. Double-click on the "WinCCflexible2008_SP3_upd3.exe" file. 2. Select the "C:\WinCCflexible2008_SP3_UPD3" as the installation folder in the "WinZip SelfExtractor" dialog. 3. Enable "When done unzipping open .\setup.exe" and exit the dialog by clicking "Unzip". 4. Open your project on the configuration PC. 5. Execute a full compilation with the menu command "Project > Compiler > Rebuild All...". 6. Transfer the project to the HMI device once again.
The update also copies new images to the images folder of the WinCC flexible installation. By default to: "C:\Program Files\Siemens\SIMATIC WinCC flexible\WinCC flexible Images". 1. Transfer the corresponding latest images to the HMI devices.