BUILDING SPACE PROGRAM SPACE REQUIRED A. PASSE PASSENG NGER ER TERMIN TERMINAL AL BUILDI BUILDING NG 1. Public Public Lobby Lobby Information w/ Flight Schedule Board Waiting Area (Seated) Well-Wishers Area Greeters Area Airline Ticketing Offices Waiting Area Consessions (Sales, Storage, & Seating) Snack Bar/Coffee Shops Pasalubong Shops Tables & Chairs ATM Booths Payphones Restrooms Male Female PWD Water Feature Pocket Gardens Circulation Paths 2. Departur Departuree Area Area Baggage Trolley Parking Curbside Queuing Terminal Entrance Passenger & Baggage Screening Passenger Lobby (seated) Pass-through area Queuing for Check-in Self-Service Check-in
No. of No. of Units Users
Area per Person 2
(in m )
1 1 1 1 3 3
4 75 30 30 3 20
1.5 0.7 0.65 0.65 2.5 0.65
3 2 10 2 2 1 1 1 1 4 1
3 3 4 1 1 6 7 1 1 1 1
2.5 2 1.5 2 1.5 1.65 1.65 3.1 28 7 28
1 2 2 1 1 1 4 2
1 20 1 1 40 1 20 1
16 1.6 4 110.25 0.7 25 1.6 1.5
Total Area 2
(in m )
2,694.6 392.6 8.0 35.0 19.5 19.5 22.5 42.0
Location & Remarks*
*those marked 2/F are on the 2nd Floor, all others are on the ground floor
(building footprint) between Departure Entrance & Arrival Exit conspicuous location in open space center of public lobby, wide seats w/ luggage space departure side arrival side at attached to building includes aisle
22.5 sales counter, prep area, display & storage 12.0 sa sales counter, display & storage 60.0 sh shared by concessionaires 4.0 includes queuing area 3.0 includes queuing area 9.9 2 WC, 4 urinals, 3 lavatories 11.6 7 WC, 3 lav 3.1 1.7 x 1.8 minimum dimensions 40.0 approx. 10% of public lobby 40.0 approx. 10% of public lobby 40.0 approx. 10% of public lobby 1,675.2 mostly natural ventilation 16.0 1 x 0.7 trolley; 2 stacks of 20 (+0.4 per trolley) 64.0 on one area each per entrance (spare) 8.0 on one regular, one spare (open only during peak) 110.3 3 units metal detector, 2 units xray, plus clearances 28.0 wi w ider seats w/ space for luggage 25.0 2. 2.5m x 10m (length of counter) 128.0 ma m ax of 4 lines, 20 pax during peak 3.0 fo for future, includes queuing A Domestic Airport for Roxas City | 1 of 15
BUILDING SPACE PROGRAM
392.6
88.0
314.3
A Domestic Airport for Roxas City | 2 of 15
BUILDING SPACE PROGRAM SPACE REQUIRED
Check-in Counters Baggage Conveyor Support Offices Outbound Baggage Room Terminal Fee Booths Circulation Hallways Escalator Elevator Stairs Payphones Restrooms Male Female PWD Janitor's Closet Pre-departure Screening Queuing Area Hand-carry X-ray Station Departing Lounge Wheelchair slots Aisles/Circulation Laptop/Gadget Charging Area Prayer Room Smoking Lounge VIP/CIP Room Restrooms - Male - Female 3 . Mabuhay Lounge (PAL Bsns Class) 2 5 9 Contingency Lounge
No. of No. of Units Users
Area per Person 2
(in m )
4 1 3 1 2
2 1 4 1 1
2.5 20 2.5 90 2.5
1 1 1 1 2 1 1 1 1
1 1 1 1 1 4 5 1 1
20.0 19 6.85 14.4 1.5 1.65 1.65 3.1 2
2 1 1 2 1 1 1 1 1 1 1 1 1
25 1 320 1 1 6 1 10 10 2 2 10 40
1.4 70 0.7 1.2 45 1.4 7.5 0.7 1.4 1.65 1.65 1.4 2
Total Area 2
(in m )
Location & Remarks*
*those marked 2/F are on the 2nd Floor, all others are on the ground floor
20.0 2 regular, 2 spare (for express, during peak) 20.0 behind counter 30.0 for CAAP, or airline crew 90.0 can handle 2 simultaneous flights 5.0 includes queuing area 20.0 approx. 10% of passenger lobby 19.0 based on Otis Link™ specifications, 1m-width 6.9 based on Otis Hydrofit™ 15 pax hydraulic elevator 14.4 1.5 m width, 0.174 rise, 23 steps, U-type 3.0 includes queuing area 6.6 1 WC, 3 urinals, 2 lavatories 8.3 5 WC, 3 lav 3.1 1.7 x 1.8 minimum dimensions 2.0 0.75 x 2 m 2/F 70.0 2/F, peak at 25 pax per queue 70.0 1 xray machine, 2 metal detectors, clearances 224.0 2/F, artificial ventilation 2.4 min of 1 for every 200 pax 45.0 approx 20% of departing lounge 8.4 7.5 2.5 x 3 7.0 2/F, natural ventilation 14.0 2/F, artificial ventilation 3.3 1 WC, 1 urinal, 2 lavatories 3.3 2 WC, 2 lavatories 14.0 2/F, artificial ventilation 80.0 for delayed flights, extra pax during peak season A Domestic Airport for Roxas City | 3 of 15
BUILDING SPACE PROGRAM
140.0
63.3
20.0
140.0
A Domestic Airport for Roxas City | 4 of 15
BUILDING SPACE PROGRAM SPACE REQUIRED
Concessions Coffee Shops Snack Bars/Restaurants Pasalubong/Gift Shops Newstand Telecom booth Service Corridor Restrooms Male Female Enplaning Gates Queuing Area Boarding Corridor 3. Arrival Area Deplaning Gates Corridor Restrooms Male Female Circulation Escalator Elevator Stairs Inbound Baggage Unloading Dock Baggage Claim w/ Conveyor System Baggage Trolley Parking Payphones Claim Stub Checking Arrival Exit Car Rental/Shuttle Service Travel Agency Booths
No. of No. of Units Users
Area per Person 2
(in m )
Total Area 2
(in m )
Location & Remarks*
*those marked 2/F are on the 2nd Floor, all others are on the ground floor
2 2 2 1 1 1 1 1 2 2 1
1 1 1 1 1 1 5 7 1 40 1
24 24 15 10 10 36 1.65 1.65 3 0.65 54
1 1 1 1
1 1 4 5
7.5 27 1.65 1.65
182.0 2/F, artificial ventilation 48.0 inclusive of 10 seats for dining 48.0 inclusive of 10 seats for dining 30.0 10.0 10.0 36.0 8.3 2/F, 2 WC, 3 urinals, 3 lavatories 11.6 7 WC, 4 lavatories 6.0 2/F, inclusive of airline security check 52.0 2/F, 2 lines per gate; 20 pax per queue 54.0 2/F, 1.8 x 30 m corridor 756.1 natural ventilation 7.5 2/F, provide counter w/ visitors stools, sofa 27.0 2/F, 1.8 x 15 m corridor 6.6 2/F, 1 WC, 3 urinal, 2 lavatories 8.3 5 WC, 3 lav
1 1 1 1 1 1 2 1 1 3 2
1 1 1 1 1 1 1 1 1 1 1
19 6.85 14.4 90 500 60 1.5 2 4 1.5 1.5
19.0 based on Otis Link™ specifications, 1m-width 6.9 based on Otis Hydrofit™ 15 pax hydraulic elevator 14.4 1.5 m width, 0.174 rise, 23 steps, U-type 90.0 can handle 2 simultaneous flights 500.0 2 conveyor systems; can accommodate 2 flights 60.0 max of 200 trolleys 3.0 includes queuing area 2.0 4.0 4.5 3.0 A Domestic Airport for Roxas City | 5 of 15
BUILDING SPACE PROGRAM
722.7
89.6
655.0
71.5
A Domestic Airport for Roxas City | 6 of 15
BUILDING SPACE PROGRAM SPACE REQUIRED
Waiting Area 4. Offices & Related Facilities Airline Support Facilities Flight Crew Lounge Restrooms, 1 M/1F Aircraft Cleaning Staff Room/Storage Inflight Snack Prep Room Airport Offices Reception Waiting Area Airport Director's Office Deputy Director Executive Secretary Restroom (M/F) Anteroom Legal Counsel Office Public Affairs Officer Legal Affairs Clerk Business Development Office Corporate Planning Head Leasing Manager Airline Relations Officer Clerks 5 1 . 2 Finance Department Office 9 1 Accountant Bookkeeper Budget Officer Accounting Clerks Administrative Office HR Manager
No. of No. of Units Users
Area per Person 2
(in m )
1
40
1.5
1 2 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
12 2 1 3 2 10 1 1 12 1 1 1 1 1 1 1 1 1 2 1 1 1 1 4 1 1
1.6 1.7 10 2.5 2.5 0.65 9 7.5 5 2.25 6 7.5 5 2.5 7.5 5 5 5 2.5 7.5 5 5 5 2.5 7.5 5
Total Area 2
(in m )
Location & Remarks*
*those marked 2/F are on the 2nd Floor, all others are on the ground floor
60.0 extension of public lobby 682.7 secured area 19.2 6.8 10.0 15.0 5.0 6.5 9.0 7.5 60.0 2.3 6.0 7.5 5.0 2.5 7.5 5.0 5.0 5.0 5.0 7.5 5.0 5.0 5.0 10.0 7.5 5.0
located on airside, between departure & arrival secured, handled by 1 or 2 receptionists central to all business offices
serves 3 personnel reception area
private office
open planning, low partitions private office
A Domestic Airport for Roxas City | 7 of 15
BUILDING SPACE PROGRAM
682.7
51.0
29.75
15.0
27.5
32.5
A Domestic Airport for Roxas City | 8 of 15
BUILDING SPACE PROGRAM SPACE REQUIRED
Property Manager Procurement Officer Supply Officer Administrative Clerks Conference Room Management Staff Lounge w/ Pantry Restrooms (M + F, 3-pax) Operations Department Office Airfield Officer Aircraft Parking Coordinator Aircraft Servicing Specialists Terminal Operations Administrator Passenger Process Manager Airline Coordinator Clerks Office of the Building Administrator Administrative Assistant Housekeeping Services Electronics & Communications Office 6 . IT Room & Server Area 2 4 PA Control Room 2 Radio Control Room Chief of Airport Security Deputy Chief of Airport Security CCTV Monitoring Room Security Coordinating Room Security Personnel Assembly Security Staff Lounge & Lockers Restrooms - Male
No. of No. of Units Users
1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 6 20 10 3 1 1 1 4 1 1 1 4 1 1 4 1 4 2 2 1 1 3 15 15 15 4
Area per Person 2
(in m )
5 5 5 5 1.4 2 1.65 7.5 5 2.5 2.5 5 5 5 2.5 7.5 5 2.5 7.5 2.5 2.5 2.5 7.5 5 2.5 1.4 0.65 1.4 1.65
Total Area 2
(in m )
Location & Remarks*
*those marked 2/F are on the 2nd Floor, all others are on the ground floor
5.0 5.0 open planning, low partitions 5.0 30.0 28.0 doubles as boardroom 20.0 9.9 7.5 private office 5.0 2.5 open planning, low partitions 10.0 5.0 5.0 open planning, low partitions 5.0 10.0 7.5 private office 5.0 open planning, low partitions 10.0 7.5 private office 10.0 enclosed, climate-controlled 5.0 enclosed, accoustically-treated 5.0 enclosed, accoustically-treated 7.5 5.0 open planning, low partitions 7.5 21.0 private area 9.8 extension of lounge 21.0 contiguous with assembly area 6.6 2 WC, 2 urinals, 2 lavatories A Domestic Airport for Roxas City | 9 of 15
BUILDING SPACE PROGRAM
57.5
29.9
57.5
30.0
27.5
85.0
A Domestic Airport for Roxas City | 10 of 15
BUILDING SPACE PROGRAM SPACE REQUIRED
- Female Personnel Lounge & Pantry Restrooms - Male w/ Lockers - Female w/ Lockers CAAP Office Anteroom w/ Reception Circulation for Offices 5. Clinic Waiting Area Attending Physician Nurse Station Examination & Recuperation Area Breastfeeding Station Restroom (M/F) Circulation 6. Covered Sidewalk (Curbside) Drop-off (Departure Side) Pick-up (Arrival Side)
No. of No. of Units Users
Area per Person 2
(in m )
1 1 1 1 1 1 1
4 15 3 4 5 1 1
1.65 2 1.8 1.8 5 2.5 90
1 1 1 1 1 1 1
5 1 2 3 5 1 1
0.65 7.5 5 3.75 1.4 3.1 5
1 1
1 1
70 105
Total Area 2
(in m )
Location & Remarks*
*those marked 2/F are on the 2nd Floor, all others are on the ground floor
6.6 4 WC, 3 lavatories 30.0 5.4 1 WC, 2 urinals, 2 lavatories 7.2 4 WC, 2 lavatories 25.0 CAAP = Civil Aviation Authority of the Philippine 2.5 90.0 approx 15% of total office spaces 42.1 with access to both departure & arrival areas 3.3 7.5 general medicine 10.0 11.3 w/ 3 beds 7.0 lounge seats 3.1 PWD-compliant 5.0 approx 10% of clinic spaces 70.0 2.5 x 28 m (4 cars) 105.0 2.5 x 42 m (6 cars)
A Domestic Airport for Roxas City | 11 of 15
BUILDING SPACE PROGRAM
42.6 27.5 90.0
42.1
175.0
A Domestic Airport for Roxas City | 12 of 15
SITE SPACE PROGRAM SPACE REQUIRED I.
Area per Total Area No. of Unit (in 2 Units (in m ) 2 m)
7,423 including future expansion 2,695 193 48 496 291 3,700 approx 60% of initial dev't.
AIRPORT BUILDINGS A. PASSENGER TERMINAL BUILDING B. CARGO TERMINAL BUILDING C. AIR TRAFFIC CONTROL TOWER D. SITE MAINTENANCE & AIRCRAFT SERVICING E. EMERGENCY RESPONSE FACILITY F. AREA FOR FUTURE EXPANSIONS
II. CURBSIDE AREA A. PARKING Departure Public Parking Arrival Public Parking Long-Term Secured (Pay) Parking Staff Parking Shuttle Service Taxi Temp Parking Bus Bay Government/Police/OB Vehicles B. ACCESS & CIRCULATION C. OPEN GROUNDS/LANDSCAPING D. REQUIRED SETBACKS E. AREA FOR FUTURE EXPANSION Parking (additional 60% of all parking spaces) Access & Circulation (additional 60%)
Location & Remarks
32,472 including future expansion
120 120 70 70 10 20 2 10 1 1 1
15 15 15 15 18 15 30 18 9000 6000 1800
1,800 1:3 pax 1,800 1:3 pax 1,050 approx. 20% of departing pax 1,050 1:2 staff 180 300 60 180 9,000 15m x 600 m (estimate/not yet fixed) 6,000 1,800
1 1
3852 5400
3,852 5,400
A Domestic Airport for Roxas City | 13 of 11
SITE SPACE PROGRAM SPACE REQUIRED III. AIRSIDE AREA A. RUNWAY B. BACKOFF/MANUEVERING C. APRON D. GROUND SUPPORT CIRCULATION E. OPEN GROUNDS F. REQUIRED SETBACKS G. AREA FOR FUTURE EXPANSION Additional Aprons Backoff/Maneuvering TOTAL AREA (INCLUDING FUTURE EXPANSION) TOTAL AREA OF SITE
Area per Total Area No. of Unit (in 2 Units (in m ) 2 m)
2 2 1 1 1
2700 3500 4000 2700 480
471,980 440,000 5,400 7,000 4,000 2,700 480
2 2
3500 2700
7,000 5,400
Location & Remarks
including future expansion as per site provided minimum, based on Airbus A320 airc based on Airbus A320 aircraft 10m x 400 m (estimate/not yet fixed)
511,875 512,000
A Domestic Airport for Roxas City | 14 of 11
DESIGN 8-C A
DOMESTIC
AIRPORT
SITE & BUILDING SPACE PROGRAM
SUBMITTED BY: MARK G. DELFIN BS ARCH 4-C
SUBMITTED TO: ARCH. VINCENT RAYMUND Y. ALOVERA INSTRUCTOR