Security System of TFD Project Author : Ade Eka Saputri
Step by Step How to Configure ACS Intercom System A. Intercom Server to Intercom Base Station : 1. Make sure all wiring and termination is correct.
Picture 1. Wiring and Termination Drawings for Intercom 2. Wiring connection in Intercom Server
Picture 2. Wiring in Intercom Server
3. Wiring connection from Terminal Block to Base Station is like picture 1. Connection from Terminal Block have 4 port connection, such as : 1 (POWER) *unused 7 (POWER) *unused 13 (Data A) / Brown Cable 19 (Data B) / White Brown Cable
Security System of TFD Project Author : Ade Eka Saputri Refer to manual, since for Base Station and Outdoor Base Station power is included in Data A and Data B, means we just need connection Data A and Data B. Wiring connection in the TB is port 13 and 19, see below picture :
Data A
Data B
Picture 3. Terminal Block Wiring from Intercom Server to Intercom Base Station
Use these 2 connections wiring to Intercom Base Station with RJ-11/ RJ-12 connector. 4. Wiring connection to Base Station, such as : Blue White Blue Brown White Brown
(POWER) *unused (POWER) *unused (Data A) (Data B)
Picture 4. RJ-11 / RJ-12 wiring for Connection for Base Station
Security System of TFD Project Author : Ade Eka Saputri 5. Plugging the connection of RJ-11 / RJ-12 to the Base Station
Picture 5. RJ-11 / RJ-12 for Connection to Base Station
6. Base Station automatically turn on after RJ-11 / RJ-12 plugged
Picture 6. Base Station Turn On
Security System of TFD Project Author : Ade Eka Saputri
B. Intercom Server to Intercom Outdoor :
1. Make sure all wiring and termination is correct.
Picture 1. Wiring and Termination Drawings for Intercom 2. Wiring connection from Terminal Block to Base Station is lik e picture above. Connection from Terminal Block have 4 port connection, such as : 5 (POWER) *unused 11 (POWER) *unused 17 (Data A) / Orange Cable 23 (Data B) / White Orange Cable Refer to manual, since for Base Station and Outdoor Base Station power is included in Data A and Data B, means we just need connection Data A and Data B. Wiring connection in the TB is port 17 and 23, see below picture :
Data A
Data B
Picture 2. Terminal Block Wiring from Intercom Server to Intercom Outdoor Station
Security System of TFD Project Author : Ade Eka Saputri Use these 2 connections wiring to Intercom Base Station with pluggable screw terminals. 7. Wiring connection to Outdoor Station, such as : Orange White Orange Green White Green
(POWER) *unused (POWER) *unused (Data A) (Data B)
Picture 3. Wiring for Connection for Outdoor Station 8. Setting Jumper inside Outdoor Station
Picture 4. Setting Jumper for Outdoor Station
Security System of TFD Project Author : Ade Eka Saputri 9. Outdoor Station automatically turn on
Picture 5. Outdoor Station Turn On
Security System of TFD Project Author : Ade Eka Saputri
C. How to Make a Call : 1)
For Call Specific to the Base Station : - Press Base Station number, e.g : 101 (Base Station will be accepted call automatically, without press any key)
2)
For Fast Dial Call to the Base Station : - Press T or 0 key (for call to all Base Station), then Base Station will be ringing and should be press (Enter) key for accept the call (since this call is fast dial to all Base Station)
D. How to Changed message on the screen of Wallmount Station : 1. Connect port LAN of the Intercom Server to the port LAN of the PC/Laptop 2. Install WinPcap (software package from Commend Intercom)