PETROSYNC PETRO SYNC
A lot of Case Studies, Practical Things and Exercises !
Synchronize Your Petroleum Skills
API 571 Damage Mechanisms Affecting Fixed Refining Equipments Sculpt Your Skills to Detect, Evaluate, and Prevent Prevent Various Degradations Degradations and Damages Inflicted on Equipment Equipment !
7th July 2014 - 9th July 2014, Bangkok, Thailand
Petrosync Distinguished Instructor Uday B. Kale (M. Eng. Mechanical) Techni Technical cal Direct Director or KUB Quality Services
SUMMARY OF PROFESSIONAL ACHIEVEMENT
PARTIAL CLIENT LIST
API 580 Risk Based Inspection Supplementary Certification API 510 & 570 Authorized Inspector AWS Certified Welding Inspector CSWIP 3.1 Authorized Welding Inspector ACCP Professional Level III (ASNT) ASNT NDT Level III BS EN 473 Level III
The Middle East: Qatar Petroleum, QAFAC, ADCO, ADGAS, ADMA, GASCO, Banagas, Technip (Bahrain), Equate Petrochemicals Company, Al Jubail Fertilizer Company, TUV Akadamie Middle East (UAE, Saudi Arabia and Qatar) Africa: BP - GUPCO (Egypt), Inspection and Test Nigeria Ltd India & Asia: Oil India Limited, Tata, Dacon Inspection Ltd Europe: Rosen Europe (The Netherlands)
Course Objectives Understanding of the various degradations and damages inflicted on equipment in Refinery S ervice Knowledge of how to detect, evaluate, and prevent degradations and damages of Refinery Equipment Advanced information information in preventive as well as predictive maintenance of equipment Different forms of degradations and various mechanisms and related environmental factors. Factorss contributing the damage, the correct monitoring & inspection of damage, prevention/mitigation of damage Factor mechanisms.
Specially Designed for Plant inspection engineers and managers, Inspection personnel, plant operating engineers Maintenance engineers and technicians and people involve involved d in trouble shooting shooting of plant operations. operations. will will have immense benefit benefit from this course in terms of identifying, identifying, understanding, understanding, prevention and mitigation mitigation of corrosion corrosion mechanisms mechanisms and related damages of refinery equipment. equipment.
Supported by
API 571 - Damage Mechanisms Affecting Fixed Refining Equipments 7th - 9th July 2014, Bangkok, Thailand Course Overview
This 3 days training course is designed to give a detailed discussion on the required API 571 document containing Practical information and guidance on damage mechanisms that can affect process equipment, assistance regarding the type and extent of damage, and How this knowledge can be applied to the selection of effective inspection methods to detect size and characterize damage. API 571 is means for imparting knowledge to the participants with damage mechanisms which are important when implementing the API Inspection Codes (API 510, API 570, API 653) and in conducting risk based inspection per API 580 and API 581. Refineries and chemical plants contain many different processing units, each having its own combination of aggressive process streams and temperature/pressure conditions. This course helps the participants to understand easily the various degradations and damages inflicted on equipments and how to detect, evaluate, and prevent them.
Course Agenda
Introduction to Damage Mechanisms Types of Damages- Thinning, Cracking, Metallurgical, Mechanical damages Common damage mechanisms encountered in Refining Industry Brittle Fracture Thermal Fatigue Erosion/Erosion Corrosion Mechanical Fatigue Atmospheric Corrosion Corrosion Under Insulation (CUI) Cooling Water Corrosion Boiler Water Condensate Corrosion Sulfidation Chloride Stress Corrosion Cracking (ClSCC) Corrosion Fatigue Caustic Stress Corrosion Cracking (Caustic Embrittlement) Wet H2S Damage (Blistering/HIC/SOHIC/SCC) High Temperature Hydrogen Attack (HTHA) Temper Embrittlement Microbiologically Induced Corrosion (MIC) Soil Corrosion Sulfuric Acid Corrosion Amine Corrosion High Temp H2/H2S Corrosion Hydrofuoric (HF) Acid Corrosion Other Damage Mechanisms in Refining Industry Inspection, Prevention and Mitigation Mock Examination and Feed back
API 571 - Damage Mechanisms Affecting Fixed Refining Equipments 7th - 9th July 2014, Bangkok, Thailand
Petrosync Distinguished Instructor INSTRUCTOR
Uday B. Kale (M. Eng. Mechanical) Technical Director KUB Quality Services
SUMMARY OF PROFESSIONAL ACHIEVEMENT
PARTIAL CLIENT /PROJECT LIST
API 510 & 570 Authorized Piping Inspector
Qatar Petroleum
AWS Certified Welding Inspector
BP - GUPCO (Egypt)
CSWIP 3.1 Authorized Welding Inspector
Oil India Limited
ACCP Professional Level III (ASNT)
ADCO (Abu Dhabi)
ASNT NDT Level III
ADGAS (Abu Dhabi)
BS EN 473 Level III
ADMA (Abu Dhabi)
API 580 Risk Based Inspection Supplementary Certification
GASCO (Abu Dhabi)
API 510 Authorized Pressure Vessel Inspector
QAFAC
API 580 Risk Based Inspection Supplementary Certification
Rosen Europe (The Netherlands)
API 653 Authorized Aboveground Storage Tank Inspector
Banagas (Bahrain)
Uday B. Kale is an API570 authorized piping inspector. Currently he is the technical director of M/s KUB Quality Services. He has involved in inspection, welding and NDT projects in the Middle East, Africa and India for over 15 years on offshore production platform and petrochemical refineries.
TATA (India) Al Jubail Fertilizer Company Technip (Bahrain) Equate Petrochemicals (Kuwait) TUV Akadamie Middle East (UAE, Saudi Arabia and Qatar) Inspection and Test Nigeria Ltd
Mr. Uday is very well-versed in international Codes and Standards. He performed and led the shutdown teams in performing NDE, internal and external inspection of equipments in central processing plant, ammonia plant, FCCU, SRU, SWS and amine treating units for Code stamp facilities of ADCO, Qatar Petroleum, Oil India, QAFAC, Banagas, Al Jubail Fertilizer Company . He was the appointed plant inspector for BP (GUPCO) in asset integrity management, who took charge of 9 offshore production complex, 75 Satellites and Onshore process units involving Close Visual Inspection of piping, equipments, NDT co-ordination, Baseline and Corrosion Monitoring. Furthermore, as an Inspector in GASCO OAG pipeline project, he conducted and witnessed Ultrasonic Examination of first 50 production weld joints of pipeline done by PWT (Pipe Welding Technology, GMAW).
Dacon Inspection Ltd HBJ pipeline up-gradation projects
With his extensive involvement in various projects, Mr. Uday is also an enthusiastic and knowledgeable mentor, who has been a faculty in training, examination, qualification and certification of API 510 & 570, ASME B31.3, API653, welding and NDT in the Middle East, Africa and Asia. He is a charted engineer with a Masters in Mechanical Engineering.
API 571 - Damage Mechanisms Affecting Fixed Refining Equipments 7th - 9th July 2014, Bangkok, Thailand
INVESTMENT PACKAGES
PROGRAMME CONSULTANT
Please checklist the package that you are attending!
Name Email Phone Fax
Deadline
Course Fee
Standard Price
4th Jul 2014
SGD $ 2,250
Early Bird Offer
7th Jun 2014
SGD $ 2,050
4th Jul 2014
10% discounts for group of 3 registering from the same organization at the same time
Investment Package
Group Discount (3 or more Delegates)
: Cay Aagen :
[email protected] : +65 6415 4500 : +65 6826 4322
TERMS AND CONDITIONS DISCLAIMER
Group Discount is based on Standard Price * To enjoy the promotion & discount offer, payment must be made before deadline * For 7 or more delegates, please inquire for more attractive package. * Prices include lunches, refreshments and materials. Promotion & discount cannot be combined with other promotional offers. * Important: Please note that registration without payment will incur a SGD 200 administration fee.
Please note that trainers and topics were confirmed at the time of publishing; however, PetroSync may necessitate substitutions, alterations or cancellations of the trainers or topics. As such, PetroSync reserves the right to change or cancel any part of its published programme due to unforeseen circumstances. Any substitutions or alterations will be updated on our web page as soon as possible.
DATA PROTECTION
DELEGATES DETAILS Mr
1st Delegate Name
Direct Line Number:
Email:
Job Title:
Department:
Mrs
Ms
Dr
Others
Head of Department:
The information you provide will be safeguarded by PetroSync that may be used to keep you informed of relevant products and services. As an international group we may transfer your data on a global basis for the purpose indicated above. If you do not want us to share your information with other reputable companies, please tick this box
CANCELLATION POLICY
2nd Delegate Name
Direct Line Number:
Email:
Job Title:
Department:
Mr
Mrs
Ms
Dr
Others
Mr
Mrs
Ms
Dr
Others
Head of Department: 3rd Delegate Name
Direct Line Number:
Email:
Job Title:
Department:
Head of Department:
INVOICE DETAILS Attention Invoice to: ______________________________________________________________________________
You may substitute delegates at any time as long as reasonable advance notice is given to PetroSync. For any cancellation received in writing not less than fourteen (14) working days prior to the training course, you will receive a credit voucher worth total transaction with less a SGD 200 administration fee and any related bank or credit card charges. Delegates who cancel less than fourteen (14) working days of the training course, or who do not attend the course, are liable to pay the full course fee and no refunds will be granted. In the event that PetroSync cancels or postpones an event for any reason and that the delegate is unable or unwilling to attend in on the rescheduled date, you will receive a credit voucher for 100% of the contract fee paid. You may use this credit voucher for another PetroSync to be mutually agreed with PetroSync, which must occur within a year from the date of postponement.
Direct Line Number: ______________________________ Fax: _____________________________________________ Company:____________________________________________ Industry : __________________________________ Address: _______________________________________________________Postcode: _________________________ Country: ________________________Email: __________________________________________________________ Please note: - Indicate if you have already registered by Phone Fax Email Web - If you have not received an acknowledgement before the training, please call us to confirm your booking.
CERTIFICATE OF ATTENDANCE
PAYMENT METHODS By Credit Card : Please debit my credit card:
Visa
MasterCard
Card Number:
AMEX
70% attendance is required for PetroSync's Certificate of Attendance.
Security Code:
DETAILS
Expiry Date:
Name printed on card: _____________________________________________________________________
PetroSync is not responsible for any loss or damage as a result of the cancellation policy. PetroSync will assume no liability whatsoever in the event this event is cancelled, rescheduled or postponed due to any Act of God, fire, act of government or state, war, civil commotion, insurrection, embargo, industrial action, or any other reason beyond management control.
By Direct Transfer : Please quote invoice number(s) on remittance advice PetroSync LLP Bank details: Account Name: PetroSync LLP Bank Number: 7144 • Branch Code: 013 • Account No: 13-1-005531-6 Name of Correspondent Bank : Standard Chartered Bank, 6 Battery Road, Singapore 049909 SWIFT Code of Correspondent Bank: SCBLSGSGXXX All bank charges to be borne by payer. Please ensure that PetroSync LLP receives the full invoiced amount.
Please accept our apologies for mail or email that is incorrectly addressed. Please email us at
[email protected] and inform us of any incorrect details. We will amend them accordingly.
CHARGES & FEE(s) - For Payment by Direct TelegraphicTransfer, client has to bear both local and oversea bank charges. - For credit card payment, there is additional 4% credit card processsing fee.
Course Confirmation I agree to PetroSyn c’s ter ms & condi tions,payment terms and cancellation policy. :
Authorized Signature
____________________________________________________________________________
PAYMENT TERMS : Payment is due in full at the time of registration. Full payment is mandatory for event attendance.