After a cryogenic liquid has been liquefied and purified to the desired level it should then be put away and transported. Cryogenic fluid storage vessel and transfer line design has progressed rapidly as a result of the growing use of cryogenic liqui
Full description
A Cheat Sheet for the TAU test in Data Structures.
Full description
Gas Turbine Data SheetDescription complète
DataFull description
Full description
injector data sheet with all caracteristics
Sample pump data sheet API 610Full description
A Cheat Sheet for the TAU test in Data Structures.
gcemFull description
The Data Sheet for the Fluke 114 Multimeter
Descripción completa
HT motorsFull description
REDLION - Data Station Plus - Sistema gateway e dataloggerDescripción completa
Dokumentnummer DOCUMENTNUMBER
Cryogenic Vessel T18V490
10066557
Dokumentversion
03
DOCUMENTVERSION
Data Sheet
Seite
1 von 12
PAGE
OF
PSP-Element
Projektbezeichnung
Materialnummer
WBS ELEMENT
PROJECT DESCRIPTION
MATERIALNUMBER
E00357
LITS Leading International T nternational T ank S ank Standard
Vacuum Insulated Storage Vessel for Liquid Nitrogen, Oxygen and Argon
D = 3000 mm H = 11514 mm
Sample: Vessel with options
Abteilung / DEPT. Datum / DATE Name / NAME
Linde AG – Engineering Division
Bearbeiter
Geprüft
Qualitäts-Planung
Schweißtechnik
Genehmigung
EDITOR
CHECKED
QUALITY-PLANNING
WELDING ENGINEER
APPROVED
LE_SCH_MFSP LE_SCH_MFSP 24.05.2013 24.05.2013 MC CAFFERY MAIER Die Linde AG behält sich für dieses Dokument alle Rechte gemäß DIN ISO 16016 vor. Linde AG reserves all rights for this document according to DIN ISO 16016. ZPL_DE_003
LE_SCH_MFS 24.05.2013 EHEGARTNER
NDC/10066557/03/000
Dokumentnummer
Cryogenic Vessel T18V490 Data Sheet
DOCUMENTNUMBER
10066557
Dokumentversion
03
DOCUMENTVERSION
Seite
2 von 12
PAGE
OF
Table of Contents 1.
General Technical Data......................................................................................................... 3
Design Pressure Design Temperature Maximum Allowable Working Pressure Maximum Allowable Working Temperature Material
Inner Vessel
19,4 barg
Outer Jacket
-1 barg
Inner Vessel
-196 °C / +20 °C
Outer Jacket
+50 °C
Inner Vessel
0 / 18 barg
Outer Jacket
-1 / 0 barg
Inner Vessel
-196 °C / +20 °C
Inner Vessel
Stainless Steel
Outer Jacket
Carbon Steel
Gross Volume
49.020 l
Ullage (Voidage)
5%
Net Volume
46.540 l
Weight Empty (± 10%)
17.570 kg
Weight Filling (Medium at 0 barg Equilibrium)
Boil-Off Rate
Discharge Capacity (For 8h continuous Operation, 20 °C ambient Temperature with standard pressure building coil at 0,7 x MAWP/ Vessel Set Pressure 10 barg)
Pressure Safety Valve Capacity
LIN
37.630 kg
LOX
53.180 kg
LAR
64.965 kg
LIN
0,21 %/d
LOX
0,13 %/d
LAR
0,15 %/d
LIN
600 Nm³/h
LOX
750 Nm³/h
LAR
750 Nm³/h
LIN
1.090 kg/h
LOX
1.010 kg/h
LAR
1.240 kg/h
Vessel cleaned for LOX acc. EN 12300-O2
Linde AG – Engineering Division
ZPL_DE_003
NDC/10066557/03/000
Dokumentnummer
Cryogenic Vessel T18V490 Data Sheet
DOCUMENTNUMBER
10066557
Dokumentversion
03
DOCUMENTVERSION
Seite
4 von 12
PAGE
OF
2. P&ID
Level Indicator not included in scope of delivery. Choose Level Indicator otherwise CE- approval will not be granted.
Linde AG – Engineering Division
ZPL_DE_003
NDC/10066557/03/000
Dokumentnummer
Cryogenic Vessel T18V490 Data Sheet
Linde AG – Engineering Division
ZPL_DE_003
DOCUMENTNUMBER
10066557
Dokumentversion
03
DOCUMENTVERSION
Seite
5 von 12
PAGE
OF
NDC/10066557/03/000
Dokumentnummer
Cryogenic Vessel T18V490 Data Sheet
DOCUMENTNUMBER
10066557
Dokumentversion
03
DOCUMENTVERSION
Seite
6 von 12
PAGE
OF
3. Valves – Instrumentation Tag
DN
PN
Description
1
40
50
Globe Valve with Check Function
Bottom Filling
2
40
50
Globe Valve
Pressure Build-Up
3
25
50
Globe Valve
Vent Valve
4
6
50
Compact Valve Manifold
Bottom Gauge (+)
5
6
50
Compact Valve Manifold
Gauge Bypass
6
6
50
Compact Valve Manifold
Top Gauge (-) (locked open)
11
40
50
Globe Valve
Discharge
12
25
50
Globe Valve
Top Filling
13
25
50
Globe Valve
Gas Shut-Off
18
20
50
Diverter Valve
Change-Over Valve
21
15
50
Globe Valve
Trycock
SV-1
20 (in) – 25 (out) 50
Safety Valve (Set=18 barg)
Pressure Safety Valve
SV-2
20 (in) – 25 (out) 50
Safety Valve (Set=18 barg)
Pressure Safety Valve
PC
25
40
Pressure Controller (Set=10 barg)
Pressure Build-Up Regulator
NRV
15
40
Non Return Valve
Non Return Valve
RV/O
150
n.a.
Relieve Valve
Relieve Valve Outer Jacket
9-1
50
n.a.
Evacuation Connection
Evacuation Connection
Tag
Description
PI
Pressure Indicator Pressure Build-Up Vaporizer Discharge Line L/11-1 Discharge Line L/11-2 (plugged) Discharge Line L/11-3 (plugged)
D L/11-1 L/11-2 L/11-3
Linde AG – Engineering Division
ZPL_DE_003
NDC/10066557/03/000
Dokumentnummer
Cryogenic Vessel T18V490 Data Sheet
DOCUMENTNUMBER
10066557
Dokumentversion
03
DOCUMENTVERSION
Seite
7 von 12
PAGE
OF
4. Connections
Linde AG – Engineering Division
ZPL_DE_003
NDC/10066557/03/000
Dokumentnummer
Cryogenic Vessel T18V490 Data Sheet
DOCUMENTNUMBER
10066557
Dokumentversion
03
DOCUMENTVERSION
Seite
8 von 12
PAGE
OF
Fill Flange
Fill Flange suitable for Flange DN40 PN40 acc. EN 1092-1
Material: Stainless Steel
Discharge Line L/11-1
Lifting Lugs:
Material: Stainless Steel
With Stainless Steel inla s
Discharge Line L/11-2 (plugged)
Discharge Line L/11-3 (plugged)
Material: Stainless Steel Linde AG – Engineering Division
ZPL_DE_003
Material: Stainless Steel NDC/10066557/03/000
Dokumentnummer
Cryogenic Vessel T18V490 Data Sheet
DOCUMENTNUMBER
10066557
Dokumentversion
03
DOCUMENTVERSION
Seite
9 von 12
PAGE
OF
5. Insulation The Storage Vessel is vacuum-insulated with Perlite. In Status of Delivery (warm Conditions) the Vacuum will be approx. 0,05 mbara. In Operating Conditions the Value of the Vacuum is < 0,05 mbara.
6. Vaporizer Air-Heated Pressure Build-Up Vaporizers All Storage Vessel Types are equipped with Air-Heated Pressure Build-Up Vaporizer, which are mounted beneath the Vessel. These are dimensioned for a Discharge Capacity pointed in the technical Data. For higher or continuous Discharges separate Pressure Build-Up Vaporizers have to be installed. For detailed Pressure BuildUp Vaporizer Dimensioning see LINDE Brochure of Air-Heated Vaporizers or contact our Sales Department.
Air-Heated Product Vaporizers These Vaporizers are available for Discharge Capacities from 60*) Nm³/h up to 2.450*) Nm³/h. For detailed Product Vaporizer Dimensioning see LINDE Brochure of Air-Heated Vaporizers or contact our Sales Department. *)
For 8h continuous Operation, Medium N2, 20°C ambient Temperature and Gas outlet Temperature 15°C below ambient Temperature
7. Corrosion Protection Surface Preparation
Acc. to DIN EN ISO 12944-4 Pre-Treatment of Surface by Sandblasting acc. to DIN EN ISO 8504-2 Blasting-Level: Sa 2 ½ (acc. to DIN EN ISO 8501-1) Coating
Primer: Two-Component Zinc Dust Primer acc. to SSPC-Paint 20 Basis: Epoxy Resin Colour: grey Dry Film Thickness: 80 µm Finish: Two Component Finish Coating Basis: Siloxane / Polyurethane Colour: Standard RAL 9016 (Traffic White) Dry Film Thickness: 100 µm Total Paint Thickness: 180 µm LINDE Corrosion Protection System is equivalent to Corrosion Protection Class: C5-I-m and C5-M-m acc. to DIN EN ISO 12944-6
Linde AG – Engineering Division
ZPL_DE_003
NDC/10066557/03/000
Dokumentnummer
Cryogenic Vessel T18V490 Data Sheet
DOCUMENTNUMBER
10066557
Dokumentversion
03
DOCUMENTVERSION
Seite PAGE
10 von 12 OF
8. Foundation
Sample: Vessel with options Linde AG – Engineering Division
ZPL_DE_003
NDC/10066557/03/000
Dokumentnummer
Cryogenic Vessel T18V490 Data Sheet
DOCUMENTNUMBER
10066557
Dokumentversion
03
DOCUMENTVERSION
Seite PAGE
11 von 12 OF
9. Proposal for Vessel Assembly The Operator is responsible for Erection, Commissioning and all relating Measures. The Requirements of the Competent Supervisory Authorities/ Regulatory Authorities have to be observed. No Basement Openings are permitted within a Radius of 5m, Drain Inlets must be provided with a Liquid Seal.
A (for T18V490) = ~4 m
This Example shows Vessel-Type T18V30
Linde AG – Engineering Division
ZPL_DE_003
NDC/10066557/03/000
Dokumentnummer
Cryogenic Vessel T18V490 Data Sheet
DOCUMENTNUMBER
10066557
Dokumentversion
03
DOCUMENTVERSION
Seite PAGE
12 von 12 OF
10. Documentation - Manufacturers Declaration of Conformity - TÜV- Certificate of Conformity - TÜV- Test Report - P & ID customised Cryogenic Vessel, including options - Certificate of Safety Valve - Manual for Operation, Commissioning and Maintenance
11. Further included in scope of basic - CE-Qualification - Logo included (Please specify type: Linde, BOC, AGA) - Permanent stainless steel transport legs included - Non corroding lifting lugs (stainless steel inlay) - Packing and loading for truck transportation included Sea freight optionally available
12. Miscellaneous - If no coupling is ordered the cryogenic vessel will be equipped with a plug-in plate for the coupling as standard. See specific data sheet no. 10079477 - Please choose options according to currently valid price list