12-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. Electr. DT
R1
R2
Y1
Y2
Y3
Y4
698 –8 – 862
880 – 96 960
X
X
X
X
X
X
65°
65°
65°
65°
65°
65°
1.5°– 10°
1.5°– 10° 1.
2.5°–12°
2.5°– 12°
2.5°– 12° 2.
2.5°– 12° 2.
1695–2690 1695 – 26 2690 1695 – 26 2690 1695 – 26 2690
set by
12-Port Antenna 698–862/880–960/1695–2690/1695–2690/1695–2690/1695–2690 65°/65°/65°/65°/65°/65° 16.5/17/17.5/17/18/17.5dBi 1.5°–10°/1.5°–10°/2.5°–12°/2.5°–12°/2.5°–12°/2.5°–12°T
80020899
Type No. Left side, lowbands Frequency Range Gain at mid Tilt Gain over all Tilts Horizontal Pattern: Azimuth Beamwidth Front-to-Back Ratio, Total Power, ± 30° Cross Polar Discrimination at Boresight Cross Polar Discrimination over Sector Azimuth Beam Port-to-Port Tracking Vertical Pattern: Elevation Beamwidth Electrical Downtilt continuously adjustable Tilt Accuracy First Upper Side Lobe Suppression Cross Polar Isolation Port to Port Isolation
R1, conne ctor 1– 2
R2, c onne ctor 3 – 4
698 – 862 MHz dBi dBi
698 – 806 16.0 15.9 ± 0.3
790 – 862 16.3 16.2 ± 0.4
880 – 960 880 – 960 16.9 16.9 ± 0.3
°
71 ± 2.5
70 ± 2.2
67 ± 3.7
dB
> 22
> 24
> 26
dB
> 22
> 22
> 21
dB
> 7.0
> 7.0
> 7.0
dB
< 2.0
< 2.0
< 2.0
°
8.6 ± 0.6
7.9 ± 0.5
7.1 ± 0.4
°
1.5 – 10.0
1.5 – 10.0
°
< 0.4
< 0.4
< 0.4
dB
> 17
> 16
> 16
dB dB
> 30 > 28 (R1 // R2) > 30 (R1 // Y1, Y2, Y3, Y4)
> 30 > 28 (R2 // R1) > 30 (R2 // Y1, Y2, Y3, Y4)
Max. Effective Power W 400 (at 50 °C ambient temperature) per Port Max. Effective Power W 800 (at 50 °C ambient temperature) Port 1–4 Values based based on NGMN-P-BASTA NGMN-P-BASTA (version 9.6) requirements. requirements.
. n o i t a r e t l a o t t c e j b u S 1 0 . 2 0 . 5 2 . 4 0 n m g n 2 4 3 5 . 6 3 9
80020899 Page 1 of 5 www.kathrein.com KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820
12-Port Antenna
Left side, lower highband Frequency Range Gain at mid Tilt Gain over all Tilts Horizontal Pattern: Azimuth Beamwidth Front-to-Back Ratio, Total Power, ± 30° Cross Polar Discrimination at Boresight Cross Polar Discrimination over Sector Azimuth Beam Port-to-Port Tracking Vertical Pattern: Elevation Beamwidth Electrical Downtilt continuously adjustable Tilt Accuracy First Upper Side Lobe Suppression
Y1, connector 5 –6 MHz dBi dBi
1695 – 1880 16.9 16.8 ± 0.4
1850 – 1990 17.2 17.1 ± 0.3
1695–2690 1920 – 2180 17.3 17.2 ± 0.4
2300 – 2400 16.7 16.6 ± 0.4
2490 – 2690 17.2 17.0 ± 0.5
°
63 ± 3.4
62 ± 3.6
62 ± 4.2
64 ± 7.3
60 ± 5.1
dB
> 22
> 24
> 24
> 21
> 22
dB
> 17
> 23
> 22
> 19
> 18
dB
> 8.0
> 9.5
> 11.5
> 8.5
> 9.0
dB
< 1.5
< 2.0
< 1.5
< 1.5
< 2.5
°
7.3 ± 0.5
6.8 ± 0.4
6.4 ± 0.6
5.7 ± 0.4
5.2 ± 0.3
°
2.5 – 12.0
°
< 0.3
< 0.3
< 0.3
< 0.2
< 0.3
dB
> 16
> 17
> 16
> 15
> 15
2300 – 2400 16.3 16.2 ± 0.3
2490 – 2690 16.9 16.8 ± 0.7
Cross Polar Isolation dB Port to Port Isolation dB Max. Effective Power W per Port Max. Effective Power W Port 5– 6 Values based on NGMN-P-BASTA (version 9.6) requirements.
> 28 > 30 (Y1 // R1, R2, Y2, Y3, Y4) 200 (at 50 °C ambient temperature) 400 (at 50 °C ambient temperature)
Left side, upper highband Frequency Range Gain at mid Tilt Gain over all Tilts Horizontal Pattern: Azimuth Beamwidth Front-to-Back Ratio, Total Power, ± 30° Cross Polar Discrimination at Boresight Cross Polar Discrimination over Sector Azimuth Beam Port-to-Port Tracking Vertical Pattern: Elevation Beamwidth Electrical Downtilt continuously adjustable Tilt Accuracy First Upper Side Lobe Suppression
Y2, connector 7– 8 MHz dBi dBi
1695 – 1880 16.6 16.6 ± 0.5
1850 – 1990 16.9 16.9 ± 0.4
1695–2690 1920 – 2180 16.9 16.9 ± 0.4
°
64 ± 3.7
63 ± 3.7
62 ± 2.9
66 ± 5.8
62 ± 5.6
dB
> 24
> 26
> 24
> 25
> 23
dB
> 15
> 22
> 25
> 18
> 16
dB
> 7.5
> 9.5
> 10.5
> 8.0
> 8.5
dB
< 1.0
< 2.5
< 2.0
< 2.5
< 2.0
°
7.0 ± 0.5
6.5 ± 0.3
6.1 ± 0.5
5.5 ± 0.4
4.9 ± 0.3
°
2.5 – 12.0
°
< 0.3
< 0.3
< 0.2
< 0.3
< 0.3
dB
> 14
> 15
> 16
> 16
> 15
Cross Polar Isolation dB Port to Port Isolation dB Max. Effective Power W per Port Max. Effective Power W Port 7–8 Values based on NGMN-P-BASTA (version 9.6) requirements.
Page 2 of 5 80020899
> 28 > 30 (Y2 // R1, R2, Y1, Y3, Y4) 200 (at 50 °C ambient temperature) 400 (at 50 °C ambient temperature)
www.kathrein.com KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820
. n o i t a r e t l a o t t c e j b u S 1 0 . 2 0 . 5 2 . 4 0 n m g n 2 4 3 5 . 6 3 9
12-Port Antenna
Right side, lower highband Frequency Range Gain at mid Tilt Gain over all Tilts Horizontal Pattern: Azimuth Beamwidth Front-to-Back Ratio, Total Power, ± 30° Cross Polar Discrimination at Boresight Cross Polar Discrimination over Sector Azimuth Beam Port-to-Port Tracking Vertical Pattern: Elevation Beamwidth Electrical Downtilt continuously adjustable Tilt Accuracy First Upper Side Lobe Suppression
Y3, connector 9 –10 MHz dBi dBi
1695 – 1880 17.7 17.6 ± 0.3
1850 – 1990 17.7 17.7 ± 0.3
1695–2690 1920 – 2180 18.0 17.9 ± 0.5
2300 – 2400 18.1 18.0 ± 0.3
2490 – 2690 18.3 18.1 ± 0.5
°
62 ± 2.5
62 ± 1.6
62 ± 1.5
61 ± 1.5
59 ± 3.0
dB
> 25
> 25
> 25
> 26
> 25
dB
> 21
> 22
> 21
> 17
> 16
dB
> 15.5
> 16.0
> 13.5
> 8.0
> 9.0
dB
< 1.0
< 0.5
< 1.0
< 1.5
< 2.5
°
7.1 ± 0.4
6.6 ± 0.3
6.3 ± 0.4
5.6 ± 0.4
5.0 ± 0.3
°
2.5 – 12.0
°
< 0.2
< 0.2
< 0.3
< 0.3
< 0.2
dB
> 20
> 22
> 21
> 18
> 22
2300 – 2400 17.8 17.7 ± 0.3
2490 – 2690 17.9 17.7 ± 0.4
Cross Polar Isolation dB Port to Port Isolation dB Max. Effective Power W per Port Max. Effective Power W Port 9–10 Values based on NGMN-P-BASTA (version 9.6) requirements.
> 28 > 30 (Y3 // R1, R2, Y1, Y2, Y4) 200 (at 50 °C ambient temperature) 400 (at 50 °C ambient temperature)
Right side, upper highband
. n o i t a r e t l a o t t c e j b u S 1 0 . 2 0 . 5 2 . 4 0 n m g n 2 4 3 5 . 6 3 9
Frequency Range Gain at mid Tilt Gain over all Tilts Horizontal Pattern: Azimuth Beamwidth Front-to-Back Ratio, Total Power, ± 30° Cross Polar Discrimination at Boresight Cross Polar Discrimination over Sector Azimuth Beam Port-to-Port Tracking Vertical Pattern: Elevation Beamwidth Electrical Downtilt continuously adjustable Tilt Accuracy First Upper Side Lobe Suppression
Y4, connector 11 –12 MHz dBi dBi
1695 – 1880 17.3 17.3 ± 0.3
1850 – 1990 17.5 17.4 ± 0.2
1695–2690 1920 – 2180 17.7 17.6 ± 0.4
°
62 ± 2.9
62 ± 1.8
61 ± 1.9
60 ± 1.8
58 ± 3.2
dB
> 25
> 24
> 24
> 25
> 24
dB
> 20
> 21
> 19
> 16
> 17
dB
> 16.0
> 17.0
> 14.5
> 8.5
> 8.5
dB
< 1.0
< 0.5
< 1.0
< 1.5
< 2.5
°
7.1 ± 0.4
6.7 ± 0.3
6.3 ± 0.4
5.7 ± 0.5
5.0 ± 0.3
°
2.5 – 12.0
°
< 0.2
< 0.2
< 0.2
< 0.3
< 0.2
dB
> 20
> 24
> 23
> 18
> 23
Cross Polar Isolation dB Port to Port Isolation dB Max. Effective Power W per Port Max. Effective Power W Port 11–12 Values based on NGMN-P-BASTA (version 9.6) requirements.
> 28 > 30 (Y4 // R1, R2, Y1, Y2, Y3) 200 (at 50 °C ambient temperature) 400 (at 50 °C ambient temperature)
80020899 Page 3 of 5 www.kathrein.com KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820
12-Port Antenna
Mechanical specifications
Electrical specifications, all systems Impedance Ω 50 VSWR < 1.5 Return Loss dB > 14 Interband Isolation dB > 28 Passive Intermodulation dBc < –150 (2 x 43 dBm carrier) Polarization ° +45, –45 1100 (at 50 °C ambient Max. Effective Power W for the Antenna temperature) Values based on NGMN-P-BASTA (version 9.6) requirements.
Input Connector Position Adjustment Mechanism Wind load (at Rated Wind Speed: 150 km/h) Max. Wind Velocity
km/h mph Height / Width / Depth mm inches Category of Mounting Hardware Weight kg lb Packing Size mm inches Scope of Supply
Accessories (order separately if required) Type No. 85010002 85010003 85010008 86010154 86010155 86010162 86010163
1 )
Remarks mm | inches
Description
N | lbf
12 x 4.3-10 female bottom FlexRET, continuously adjustable Frontal 1710 | 384 Lateral 560 | 126 Rearside 1760 | 396 200 124 2693 / 377 / 169 106.0 / 14.8 / 6.7 H (Heavy) 49.0 / 51.2 (clamps incl.) 108.0 / 112.8 (clamps incl.) 2896 / 397 / 212 114.0 / 15.6 / 8.3 Panel, FlexRET and 2 units of clamps for 42–115 mm | 1.7–4.5 inches diameter
2)
Weight Units per approx. kg | lb antenna
1 clamp Mast diameter: 110 – 220 | 4.3 – 8.7 1 clamp Mast diameter: 210 – 380 | 8.3 – 15.0 1 downtilt kit Downtilt angle: 0° – 8° Site Sharing Adapter 3-way (see figure below) Site Sharing Adapter 6-way (see figure below) Gender Adapter Solely to be used in combination with the FlexRET module 86010153 V01 Port Extender
2.7 | 6.0 4.8 | 10.6 4.3 | 9.5 0.65 | 1.4 1.35 | 3.0 0.045 | 0.099 0.16 | 0.35
2 2 1
1 1
Accessories (included in the scope of supply) 738546 86010153 V01
1 clamp FlexRET
) 3
Mast diameter: 42 – 115 | 1.7 – 4.5
1.1 | 2.4
2 1
0 1 . . 6 7 0 0 1 1 | |
7 . 8 0 1 |
3 1 9 2 6 7 2 2
1 6 7 2
For downtilt mounting use the clamps for an appropriate mast diameter together with the downtilt kit. Wall mounting: No additional mounting kit needed. Material:
Reflector screen: Aluminum. Fiberglass housing: It covers totally the internal antenna components. The special design reduces the sealing areas to a minimum and guarantees the best weather
. n o i t a r e t l a o t t c e j b u S
protection. Fiberglass material guarantees optimum performance with regards to stability,
stiffness, UV resistance and painting. The color of the radome is light grey. All nuts and bolts: Stainless steel or hot-dip galvanized steel. Grounding:
The metal parts of the antenna including the mounting kit and the inner conductors are DC grounded.
Configuration example with Site Sharing Adapter 86010154 FlexRET
FlexRET
Configuration example with Site Sharing Adapter 86010155 FlexRET
FlexRET
Site Sharing Adapter 3-way
FlexRET
All dimensions in mm | inches
FlexRET
AISG
BTS2
BTS3 BTS1
BTS2
BTS3
BTS4
BTS5
BTS6
For more information please refer to the respective data sheets.
Page 4 of 5 80020899
1 0 . 2 0 . 5 2 . 4 0 n m g n 2 4 3 5 . 6 3 9
Site Sharing Adapter 6-way
AISG
BTS1
1) ∅ 9 | 0.4 2) 72 | 2.8 3) 13 | 0.5
www.kathrein.com KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820
12-Port Antenna
Layout of interface:
Right
Le f t
* 7
7 . 6 | .
* 7 | 5 9 1
Y1
Y1
R2
Top
9 6 1
R2(L)
880 - 960
R1(L)
698 - 862
R2
Y3
Y3
Y2(L) /Y4(R) 1695 - 2690
Bottom Y1(L) /Y3(R) 1695 - 2690
6
5
Y2
4
Y2
3
R1
R1
10
9
Y4
Y4 1 . 4 | 4
8
7
2
0
12 11
1
1 1 . 2 | 4 5
124 | 4.9 224.5 | 8.8 325 | 12.8 377 | 14.8 * Bottom view * Dimensions refer to radome All dimensions in mm | inches
Correlation Table . n o i t a r e t l a o t t c e j b u S 1 0 . 2 0 . 5 2 . 4 0 n m g n
R2
Frequency range
Array
Connector
698– 862 MHz 880– 960 MHz 1695–2690 MHz 1695–2690 MHz 1695–2690 MHz 1695–2690 MHz
R1 R2 Y1 Y2 Y3 Y4
1–2 3–4 5–6 7–8 9–10 11–12
R1 1x
R1 Y2
Y4
Y1 R1 Left
Y3 Right
2 4 3 5 . 6 3 9
Any previous data sheet issues have now become invalid.
80020899 Page 5 of 5 www.kathrein.com KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820
FlexRET
A �exible, integrated solution for adjusting the electrical downtilt of Kathrein FlexRET antennas. Compliant to 3GPP/AISG 2.0 Single RETs or Multi RET displayed • Two way antenna sharing feasibility
Daisy Chain feasibility Pre-con�gured
•
•
•
•
86010153 V01
Type No.
Protocols Logical interface ex factory Operates as Ex factory Input voltage range Power consumption Connectors
compliant to 3GPP/AISG 2.0 3GPP/AISG 2.0 Single RETs or Multi RET Single RETs 10 ... 30 (pin 6) Typically < 1; < 10 (motor activated) 2 x 8 pin connector according to IEC 60130-9; according to AISG-C 485 Daisy chain in: male; Daisy chain out: female RS 485A/B (pin 5, pin 3); power supply (pin 6); DC return (pin 7); according to AISG / 3GPP 40 (typically, depending on antenna type)
V W
Hardware interfaces
Adjustment time (full range) Adjustment cycles Temperature range Protection class Lightning protection
sec
> 50,000 –40 … +60 IP 24 (installed) AISG interface (each pin) 2.5 kA (10/350 µs) 8 kA (8/20 µs) according to IEC 61000-4-5 Pro�le: Aluminum anodized; cover: Aluminum die cast coated
°C
Housing material Weight Packing size (H x W x D) Dimensions (H x W x D)
g lb mm inches mm inches
350 0.77 245 x 93 x 102 9.6 x 3.6 x 4 142 x 71 x 51 5.6 x 2.8 x 2
Please note:
If the Primary which controls the FlexRET system does not support the default ex-factory interface setting, then the FlexRET must be switched to the appropriate standard of the Primary before installation. Please contact Kathrein for further information. If the FlexRET of an antenna has to be replaced, the FlexRET gets the information stored in the antenna after power on automatically. It is not necessary to con�gure the FlexRET manually.
. n o i t a r e t l a o t t c e j b u S 4 0 2 5 . 6 3 9
Standards:
EN 60950-1 (Safety) EN 60950-22 (Safety – Equipment installed outdoor) EN 55022 (Emission) EN 55024 (Immunity) ETS 300019-1-4 (Environmental) UL 60950-1; 1st edition
Certi�cation:
CE, FCC
Scope of supply:
FlexRET
Optional:
Site Sharing Adapter (86010154 or 86010155) to create independent logical interfaces at one antenna or site. Makes it possible to operate with more than one independent Node B. Gender Adapter (86010162) to convert the AISG out (female) to an AISG in (male) port in order to operate one FlexRet with exactly 2 BTS. Detailed information is given in the data sheet of the Gender Adapter. Port Extender (86010163) to convert the existing AISG input and output in order to operate FlexRet with exactly 2 BTS while maintaining the daisy chain capability. Detailed information is given in the data sheet of the Port Extender.
Please note:
In general, the addressing of the FlexRET is automatically performed. Only in case the FlexRET is manually addressed, the serial number has to be extended by the corresponding colour coding extension (e.g. CSG351234-R1 ). The respective information can be found on the site documentation which is included in the scope of supply.
www.kathrein.com
86010153 V01 Page 1 of 4
KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820
FlexRET
Startup of FlexRET The FlexRET module included in the antenna is precon�gured with the following information: Antenna model no., Antenna Serial no., Antenna con�guration data. After connecting a control cable and scanning the antenna line devices (ALD) the used primary (e.g. NodeB, ALC, etc.) will �nd the FlexRET. You only need to insert your additional data.
Connecting the control cables:
Connect a control cable to the daisy chain input of the FlexRET. The tightening torque for �xing the connector must be 0.5 – 1.0 Nm (‘hand-tightened’). The connector should be tightened by hand or by a special torque screw driver (order no. 85010080). See also data sheet for Kathrein AISG-cable (86010007, ...). Please note: To ensure the tightness of the RET System, Kathrein recommend the use of Kathrein components only. Please note: If the daisy chain output is not used, do not remove the protection cap.
For daisy chain operation, remove the protection cap and attach a control cable to interconnect with the daisy chain input of the subsequent FlexRET or external RCU. Please note: Do not remove the protection cap on the daisy chain output of the last FlexRET or RCU device.
. n o i t a r e t l a o t t c e j b u S 4 0 2 5 . 6 3 9
Page 2 of 4 86010153 V01
www.kathrein.com
KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820
FCC – Statements
. n o i t a r e t l a o t t c e j b u S 4 0 2 5 . 6 3 9
www.kathrein.com
86010153 V01
Page 3 of 4
KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820
FCC – Statements
Compliance Information Statement (Declaration of Conformity Procedure) Responsible Party: Kathrein Address: Telephone: (+01) 00 Type of Equipment: Model Name: FlexRET FCC ID SP3-86010153
. n o i t a r e t l a o t t c e j b u S 4 0 2 5 . 6 3 9
Page 4 of 4 86010153 V01
Any previous data sheet issues have now become invalid.
www.kathrein.com
KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820
Mounting Hardware Clamp Included in the Scope of Supply
Suitable for mast diameter (mm) [inches] Antenna – mast distance (mm) [inches] Material of clamp and screws Weight
42 – 115 [1.65 – 4.53] 20 – 25 [0.79 – 0.98] Hot-dip galvanized steel / stainless steel
(kg) [lb]
1.1 [2.43]
152 [5.98] 100 [3.94] 72 [2.83]
] 8 9 . 0 5 – 2 9 – 7 . 0 0 2 [
40 [1.57]
] 7 5 . 1 [ 0 4
1 5 2 – 1 3 4 ] 4 .5 – 5 1. 6 [
M10 MA = 25 Nm
35 [1.38]
M8 MA = 20 Nm
64 [2.52] 125 [4.92]
20–25 [0.79–0.98]
. n o i t a r e t l a o t t c e j b u S c / 0 2 9 3 . 6 3 9
Please note: Kathrein does not recommend to use counter nuts. The additional nuts supplied are only meant as spares.
www.kathrein.de
Any previous data sheet issues have now become invalid.
All dimensions in mm and [inches]
738546 Page 1 of 1
KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 4 4 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820
FlexRET
A �exible, integrated solution for adjusting the electrical downtilt of Kathrein FlexRET antennas. Compliant to AISG 1.1 and 3GPP/AISG 2.0 Single RETs or Multi RET displayed
Daisy Chain feasibility Pre-con�gurated
●
●
●
●
86010153
Type No.
Protocols Logical interface ex factory Operates as Ex factory Input voltage range Power consumption Connectors
V W
Hardware interfaces
Adjustment time (full range) Adjustment cycles Temperature range Protection class Lightning protection
sec
°C
Housing material Weight Packing size (H x W x D) Dimensions (H x W x D)
compliant to AISG 1.1 and 3GPP/AISG 2.0 3GPP/AISG 2.0 Single RETs or Multi RET
1)
Single RETs 10 ... 30 (pin 1, pin 6) < 0.5 (stand by); < 10 (motor activated) 2 x 8 pin connector according to IEC 60130-9; according to AISG Daisy chain in: male; Daisy chain out: female RS 485A/B (pin 5, pin 3); power supply (pin 1, pin 6); DC return (pin 7); according to AISG / 3GPP 40 (typically, depending on antenna type) > 50,000 –40 … +60 IP 24 (installed) AISG interface (each pin) 2.5 kA (10/350 µs) 8 kA (8/20 µs) Pro�le: Aluminum anodized; cover: Aluminum die cast coated
g lb mm inches mm inches
350 0.77 245 x 93 x 102 9.6 x 3.6 x 4 142 x 71 x 50.4 5.6 x 2.8 x 2
1)
The protocol of the logical interface can be switched from 3GPP/AISG 2.0 to AISG 1.1 with a vendor speci�c command. Start-up operation of the FlexRET is only possible in a RET system supporting 3GPP/AISG 2.0!
1)
Please note:
If the Primary which controls the FlexRET system does not support the default ex-factory interface setting, then the RCU must be switched to the appropriate standard of the Primary before installation. Please contact Kathrein for further information. If the FlexRET of an antenna has to be replaced, the FlexRET gets the information stored in the antenna after power on automatically. It is not necessary to con�gurate the FlexRET manually.
. n o i t a r e t l a o t t c e j b u S b / 3 4 6 4 . 6 3 9
Standards:
EN 60950-1 (Safety) EN 60950-22 (Safety – Equipment installed outdoor) EN 55022 (Emission) EN 55024 (Immunity) ETS 300019-1-4 (Environmental) UL 60950-1; 1st edition
Certi�cation:
CE, FCC
Scope of supply:
FlexRET
Optional:
Site Sharing Adapter (86010154 or 86010155) to create independent logial interfaces at one antenna or site. Makes it possible to operate with more than one independent Node B.
Please note:
In general, the addressing of the FlexRET is automatically performed. Only in case the FlexRET is manually addressed, the serial number has to be extended by the corresponding colour coding extension (e.g. CSG351234-R1 ). The respective information can be found on the site documentation which is included in the scope of supply.
www.kathrein.com
86010153 Page 1 of 4
KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820
FlexRET
Startup of FlexRET The FlexRET module included in the antenna is precon�gured with the following information: Antenna model no., Antenna Serial no., Antenna con�guration data. After connecting a control cable and scanning the antenna line devices (ALD) the used primary (e.g. NodeB, ALC, etc.) will �nd the FlexRET. You only need to insert your additional data.
Connecting the control cables:
Connect a control cable to the daisy chain input of the FlexRET. The tightening torque for �xing the connector must be 0.5 – 1.0 Nm (‘hand-tightened’). The connector should be tightened by hand or by a special torque screw driver (order no. 85010080). See also data sheet for Kathrein AISG-cable (86010007, ...). Please note: To ensure the tightness of the RET System, Kathrein recommend the use of Kathrein components only. Please note: If the daisy chain output is not used, do not remove the protection cap.
For daisy chain operation, remove the protection cap and attach a control cable to interconnect with the daisy chain input of the subsequent FlexRET or external RCU. Please note: Do not remove the protection cap on the daisy chain output of the last FlexRET or RCU device.
. n o i t a r e t l a o t t c e j b u S b / 3 4 6 4 . 6 3 9
Page 2 of 4 86010153
www.kathrein.com
KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820
FCC – Statements
. n o i t a r e t l a o t t c e j b u S b / 3 4 6 4 . 6 3 9
www.kathrein.com
86010153
Page 3 of 4
KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820
FCC – Statements
Compliance Information Statement (Declaration of Conformity Procedure) Responsible Party: Kathrein Inc., Scala Division Address: PO Box 4580, Medford Oregon . 97501 Telephone: (+01)541 779 6500 Type of Equipment: Model Name: FlexRET FCC ID SP3-86010153
. n o i t a r e t l a o t t c e j b u S b / 3 4 6 4 . 6 3 9
Page 4 of 4
86010153
www.kathrein.com
KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820