Security Document Title
Level
1- Prepare backupBackup the NodeB CFG xml. Run CFM CB: NAME="GE", COMMENT="27oct2014"; Run DSP CB:; 2- Field engineer must call NOC and integration engineer before entering site.
1- Field engineer Connect the SFP and optical cable onsite as shown in below picture. And make sure cable are properly labeled( mention source and destination port details)
2- Set ETH port no.1 For WMPT SET ETHPORT:CN=0, SRN=0, SBT=BASE_BOARD, PN=1, MTU=1500, SPEED=100M, DUPLEX=FULL, ARPPROXY=DISABLE, FERAT=10, FERDT=8, RXBCPKTALMOCRTHD=320, RXBCPKTALMCLRTHD=288; For UMPT SET ETHPORT:CN=0, SRN=0, SBT=BASE_BOARD, PN=1, MTU=1500, SPEED=1000M, DUPLEX=FULL, ARPPROXY=DISABLE, FERAT=10, FERDT=8, RXBCPKTALMOCRTHD=320, RXBCPKTALMCLRTHD=288; DSP ETHPORT to see if port 1 is up or not. (Note- before executing Remove commend must run List command and save the result) 2016-02-23
Huawei Proprietary - Restricted Distribution
Page1, Total2
Security Document Title
Level
Modify IPPATH in RNC by command MOD IPPATH and set Rx/TX bandwidth 1000000 Kbps for UMPT NBs, but for WMPT NBs Rx/Tx BW = 100000 Kbps 3- RMV IUBCP 4- RMV SCTPLNK 5- RMV IPPATH 6- RMV DEVIP 7- ADD DEVIP( fill port no.1)///in case we edit script, just edit port number 8- ADD IPPATH( fill port no.1)//just add packet size for WMPT and UMPT 9- ADD SCTPLNK 10- ADD IUBCP 11- Check the site alarm 12- Check Visibility from M2000. 13- DSP SCTP LINK 14- DSP IPPATH 15- Check cell status by DSP UCELL. 16- Make call test voice and data 17- If all service is Normal remove Ethernet cable. 18- Inform KPI monitor team to monitor Site KPI and share to everyone 1 hour KPI. 19- Field engineer call to NOC and Integration engineer before leaving site. 20- Finish If need RollbackACT CB: NAME="GE";
2016-02-23
Huawei Proprietary - Restricted Distribution
Page2, Total2