NEC Confidential
iPASOLINK –LCT WEB
NEC Europe
LCT COMMUNICATION INTERFACE
NEC Confidential
LCT Startup and Login
Start the browser Internet Explorer and enter the URL http://172.17.254.253/weblct/ to open the WebLCT Login screen. Enter the “User Name” and “Password” in the provided text boxes and Click Ok button Default Username : Admin Password: 12345678 LCT main menu opens in the “Current Status screen”
NEC Confidential
WebLCT LOGOUT Always Logout using this button before disconnecting the cable.
To Logout of the WebLCT, click on the Logout button on the top right hand of the LCT screen. When Logout Confirm window appears, Click Yes LCT Login window appears Close the Browser window to exit WebLCT.
NEC Confidential
login to Main-2 (Standby MC-M)
Connect the LCT WEB to the standby MC-M card and login. Standby Main Card Control Setting window.
Standby Main Card Control Setting window shows the Main Card 1 and 2 Current Status information, Inventory information, Firmware and FPGA information and SFP information. This window allows H/W and F/W Reset Control of Active Main Card and Standby Main card
NEC Confidential
USER NAMES & PRIVILEGES User Group User ID
Admin Config Operator ADMIN CONFIG USER Up/Down Up/Down Upload Load Load only Get/Set Get/Set Get
File Operation SNMP Operation
USER: User is able to confirm system configuration and equipment status. It is not available to make any configuration change. Password :87654321 Default Group: :OPERATOR
CONFIG- Beside of the function can be performed by User, Config user is able to do radio management, base-band management, Switching function management for C-Plane control. Password: 87654321 Default Group: CONFIG
ADMIN- Beside of the function can be performed by Config user, Admin user is able to do database management, file management, user management and time management for M-Plane control. Password: 12345678 Default Group: ADMIN
EASY SETUP WIZARD EASY SETUP MODEM SETUP
R/W R/W
R R
R R
MANAGEMENT SETUP ETH SETUP TDM SETUP PWE SETUP
R/W R/W R/W R/W
R R R R
R R R R
EQUIPMENT SETUP EQUIPMENT CONFIGURATION
R/W
R
R
RADIO CONFIGURATION
R/W
R/W
R
AMR CONFIGURATION
R/W
R/W
R
GENERAL SETTING
R/W
R
R
GENERAL SETTING (DETAIL)
R/W
R
R
ROUTING SETTING
R/W
R
R
IP ACCESS CONTROL SETTING PROVISIONING MODEM PORT SETTING RADIO SWITCH SETTING TX POWER SETTING ALM MODE SETTING AMR Mode XPIC BRIDGE SETTING
R/W
R
R
R/W R/W R/W R/W R/W R/W R/W
R/W R/W R/W R/W R/W R/W R/W
R R R R R R R
ETH PORT SETTING
R/W
R/W
R
VLAN SETTING
R/W
R/W
R
FDB SETTING
R/W
R/W
R
ETH OAM SETTING
R/W
R/W
R
RSTP SETTING
R/W
R/W
R
QoS /CLASSIFICATION SETTING
R/W
R/W
R
OTHER ETH PORT SETTING LLF SETTING BROADCAST STORM CONTROL SETTING
R/W R/W R/W
R/W R/W R/W
R R R
NETWORK MANAGEMENT CONFIGURATION
MODEM FUNCTION SETTING
ETH FUNCTION SETTING
REMOTE-Functions available When User access Remotely but restricted by the assigned access level
REMOTE
NEC Confidential
USER NAMES & PRIVILEGES CATEGORY
ADMIN
CONFIG
USER
REMOTE
CROSS CONNECT SETTING
R/W
R/W
R
E1/ STM1/CROSS CONNECT SETTING
E1 PORT SETTING
R/W
R/W
R
STM-1 PORT SETTING
R/W
R/W
R
EQUIPMENT CLOCK/SYNCHRONIZATION SETTING
EQUIPMENT CLOCK SETTING
R/W
R/W
R
EXT CLOCK SETTING
R/W
R/W
R
PWE SETTING
R/W
R/W
R
RELAY CONTROL SETTING
R/W
R/W
R
CLUSTER ALARM SETTING
R/W
R/W
R
V.11/SC SETTING
R/W
R/W
R
V.11/DIRECTIONAL SETTING
R/W
R/W
R
OW SETTING
R/W
R/W
R
CORRELATION/ DELAY _ STRETCH SETTING AIS SETTING BER THRESH HOLD SETTING
R/W R/W R/W
R/W R/W R/W
R R R
PMON THRESHOLD
R/W
R/W
R
PROVISIONING
USER: User is able to confirm system configuration and equipment status. It is not available to make any configuration change. Password :87654321 Default Group: :OPERATOR
CONFIG- Beside of the function can be performed by User, Config user is able to do radio management, baseband management, Switching function management for CPlane control. Password: 87654321 Default Group: CONFIG ADMIN- beside of the function can be performed by Config user, Admin user is able to do database management, file management, user management and time management for M-Plane control. Password: 12345678 Default Group: ADMIN
REMOTE-Functions available When User access Remotely but restricted by the assigned access level
RELAY ALARM MAPPING SETTING
V.11/ OW SETTING
ALARM /AIS SETTING
PMON / RMON SETTING
AUX SETTING
PMON OTHER
R/W
R/W
R
RMON THRESHOLD
R/W
R/W
R
RMON OTHER
R/W
R/W
R
AUX INPUT SETTING
R/W
R/W
R
AUX OUTPUT SETTING
R/W
R/W
R
MODEM LOOPBACK CONTROL
R/W
R/W
R
TDM LOOPBACK CONTROL (E1 LB1)
R/W
R/W
R
TDM LOOPBACK CONTROL (E1 LB2)
R/W
R/W
R
TDM LOOPBACK CONTROL (STM-1 LB1)
R/W
R/W
R
TDM LOOPBACK CONTROL (STM-1 LB2)
R/W
R/W
R
MODEM TX/TX SW CONTROL
R/W
R/W
R
RSTP SW CONTROL
R/W
R/W
R
APS SWITCH GROUP CONTROL
R/W
R/W
R
SNCP SW CONTROL
R/W
R/W
R
TIMING SOURCE SW CONTROL
R/W
R/W
R
MAINTENANCE CONTROL
LOOPBACK CONTROL
PROTECTION CONTROL
NEC Confidential
♦
USER NAMES & PRIVILEGES CATEGORY
USER: User is able to confirm system configuration and equipment status. It is not available to make any configuration change. Password :87654321 Default Group: :OPERATOR
CONFIG- Beside of the function can be performed by User, Config user is able to do radio management, base band management, Switching function management for C-Plane control. Password: 87654321 Default Group: CONFIG
ADMIN- Beside of the function can be performed by Config user, Admin user is able to do database management, file management, user management and time management for M-Plane control. Password: 12345678 Default Group: ADMIN
ADMIN R/W
CONFIG R/W
USER
MODEM MAINTENANCE CONTROL
R
REMOTE
AUTO LASER SHUTDOWN CONTROL
R/W
R/W
R
H/W_F/W RESET CONTROL
H/W RESET CONTROL
R/W
F/W RESET CONTROL
R/W
PMON / RMON/ FDB CLEAR
R/W
R
OFFLINE MAINTENANCE
R/W
R
R/W
R
R
MAINTENANCE TEST
ETH OAM LB/LT/LM/DM CONTROL
CURRENT HISTORY PMON/RMON REPORT MODEM PMON REPORT
R
R
R
E1 PMON REPORT
R
R
R
STM-1 PMON REPORT
R
R
R
ETH RMON REPORT
R
R
R
VLAN COUNTER REPORT
R
R
R
R/W
R/W
R
METERING CURRENT METERING
USER ACCOUNT / SECURITY SETTING LOGIN USER
R
USER ACCOUNT MANAGEMENT
R/W
R/W
USER GROUP PROFILE CONFIGURATION SECURITY SECURITY STATUS SETTING MANAGEMENT INVENTORY
R/W
R
R
EQUIPMENT INVENTORY INFORMATION
R
R
R
R
S/W LICENSE INFORMATION
R
R
R
R
S/W LICENSE SETUP IMPORT LICENSE KEY
R/W
R
SFP PORT LICENSE SETTING
R/W
R
R
RADIO CAPACITY SETTING
R/W
R
R
REMOTE- Functions available When User access Remotely but restricted by the assigned access level
NEC Confidential
♦
USER NAMES & PRIVILEGES CATEGORY
ADMIN
CONFIG R/W
USER
REMOTE
EQUIPMENT UTILITY
USER: User is able to confirm system configuration and equipment status. It is not available to make any configuration change. Password :87654321 Default Group: :OPERATOR
EXPORT (NE -> STORAGE) UTILITY
R/W
UPDATE (STORAGE -> NE ) UTILITY
R/W
PROGRAM ROM SWITCHING
R/W
USB MEMORY UTILITY
R/W
SHIPMENT
R/W
DATE/TIME SETTING
R/W
CONFIG- Beside of the function can be performed by User, Config user is able to do radio management, base band management, Switching function management for C-Plane control. Password: 87654321 Default Group: CONFIG
ADMIN- Beside of the function can be performed by Config user, Admin user is able to do database management, file management, user management and time management for M-Plane control. Password: 12345678 Default Group: ADMIN
REMOTE- Functions available When User access Remotely but restricted by the assigned access level
NEC Confidential
R
R
WebLCT Initial Screen Login User Name
Summary Alarm Indication
Active MC-M card
Opposite Site Links
Maintenance
Indicate the current logged in user
Indicate the summary alarm of ODU, IDU, AUX I/O, TCN, & Maintenance Status
Indicate the Active MC-M card Main1 or Main2
Connect to opposite station (s)
Maintenance ON/OFF button Logout Logout button
Block Diagram Indicate the ODU, IDU and Interfaces mounted
Menu tree Indicate the LCT Main Menu Detail Display Display detail alarm & status information of items selected from the Tabs
NEC Confidential
WebLCT – Remote Login
F/W Version
Site (NE) Name and IP Address
Indicate the current Firm Ware Version
Indicate Network element name and it’s IP address Opposite Site Links Connect to opposite station (s) Connecting to opposite site
Click on the opposite site links and select the site to connect to. Cursor shows the IP Address of opposite Station. Login screen for selected opposite site open in a separate browser window
NEC Confidential
WebLCT – Remote Login Auto Mode
Hide Equipment View
Select this check box to stop auto refreshing the status
Select Hide Equipment View check box to hide the Equipment Block Diagram
ONLY IN iPASOLINK 1000
NEC Confidential
Block Diagram – iPASOLINK 1000
iPasolink 1000 Block Diagram of IDU with three ODUs connected with STM-1 , 16xE1, 2FE/2GbE interfaces and redundant Main Boards.
iPasolink 1000 Block Diagram of IDU with 6 modems and several STM1 interfaces, FE/GbE interfaces and 16xE1 interfaces. ODUs connected with redundant main boards
NEC Confidential
Active Alarms & Event Log Click on the Active Alarm Tab to see details of current Alarms Click on Save button to save the active alarm list to the PC Click on Event Log tab to see the event Log information. Click save to save the event log to a CSV file Event Log is divided in to three categories: Alarm – 1000 events Status – 1000 events Control – 1000 events Last 1000 items of each are stored.
NEC Confidential
ODU & IDU Detail Alarm and Status Click on the ODU, the MODEM or the universal Slot tab to see the detail alarm and status information of the selected Modem / ODU combination
Click on the IDU Main board in the block diagram or the IDU tab to see the detail alarm and status information of the IDU
NEC Confidential
Event Log – Filtering
Event Log columns can sort according to Ascending or Descending order . Bring the cursor to the column header and Click on the small down arrow select Sort Ascending or Sort Descending
Event Log data can be filtered based on the date. Click on the down arrow on the Date column and select accordingly
To see the Events on a particular date. Select the On check box and select the date from the calendar To see the Events after or before a particular date. Select the Before or After check box and select the date from the calendar
Event Log data can be filtered based on the Severity. Click on the down arrow on the Severity column and select accordingly
To see the Events between two dates. Select the Before and After check boxes and select the dates from the calendar
NEC Confidential
WebLCT Main Menu Menus for Metering Equipment Utility User Account / Security S/W License setup Can be accessed by selecting the check box “Detail Menu”
Click the “Expand All” icon to expand all menu items and click “ Collapsed All” icon to collapse the menu items
NEC Confidential
Main Menu
NEC Confidential
Provisioning Menu
Click the “+” to expand each main menu folder and see the sub-menu items
NEC Confidential
Maintenance Menu
NEC Confidential
EQUIPMENT SETUP
NEC Confidential
EQUIPMENT CONFIGURATION (1 of 7) Show the connected ODU frequency specification and radio setting
Click the Equipment Setup menu and select Equipment Configuration. Equipment configuration screen is displayed with the current equipment configuration settings Click the Setup icon to open the Setup wizard to select the Equipment configuration or modify the Equipment configuration. Click Next on each configuration window
Show the Adaptive Modulation function used or not and the modulations used
NEC Confidential
EQUIPMENT CONFIGURATION (2 of 7) Click the Setup icon to start the Equipment Configuration Wizard
Click the Current Equipped Card Information icon to see a list of currently equipped cards in the IDU
NEC Confidential
EQUIPMENT CONFIGURATION (3 of 7) 1
Left hand section shows the current setting
Right hand section allows the setting or modification
Green border indicate units mounted but not registered
2
1
Step-1 Setting of Equipment Name. Enter the Equipment Name ( up to 32 Characters)
NEC Confidential
2
Click the Next button to go to Step-2
EQUIPMENT CONFIGURATION (4 of 7)
Step2 Setting of Equipment Slot
3
Click on the drop down arrow of each slot and select the module inserted in the slot from the list. If the inserted modules are not known click the Auto Detect button to select automatically.
3
Select the second Power supply module if used
4
4
NEC Confidential
Click the Next button to open the Step3
EQUIPMENT CONFIGURATION (5 of 7)
Redundant MC-M card
Type of universal cards that could be mounted in each slot is indicated here. F/w ver 2.11.13
F/W Ver.1.01.11 NEC Confidential
EQUIPMENT CONFIGURATION (6 of 7) 5
Step3 Setting of Modem/STM SW/ XPIC GRP Configuration This window select the radio redundancy, XPIC group setting and STM-1 APS setting. Slots 1/ 2 is one radio and XPIC group. Slots 3 /4 is the second group. Depending on the number of modems mounted Check boxes are active. Click on the check box and select (1+1) HS or (1+1) TP
6 Each STM-1 card has two STM-1 ports. Line
protection (APS) can be selected between the two ports on the card.
5
If more than one STM-1 cards are mounted then APS can be between the cards (Different Card), or separately on each card (Same Card) 6
7
7 Click the Next button to open the Step4
Setting Confirmation Screen
NEC Confidential
EQUIPMENT CONFIGURATION (7 of 7) 8
Step4 Setting Confirmation Changes made to the Equipment configuration is shown shaded in light blue. Confirm that the changes are correct .
8
9 Click OK to apply the changes. A
window pop-up warning that the cross-connect and VLAN may be purged. Click OK to continue. After the under execution progress bar the Complete information window appears. Click OK..
9
NEC Confidential
EQUIPMENT CONFIGURATION (4 of 10) (1+1) Hot Standby Configuration
(1+1) Twin Path Configuration
(1+0) XPIC Configuration
Modems can be used in six switch groups. Slots 01 & 02 is switch group 1 and Slots 03 & 04 is switch group 2 etc.. they can be used in hot standby or twin path redundancy configurations.
NEC Confidential
RADIO CONFIGURATION (1 of 5) 1
Click the Equipment Setup Menu and select Radio Configuration to open the Equipment Setup – Radio configuration screen
NEC Confidential
2
Click the Setup Icon to open the Setup 1 Detailed MODEM Setting of SW/XPIC GRP or Slot Unit window.
RADIO CONFIGURATION (2 of 5)
Show setting for (1+1) Hot Standby
Show setting for (1+0)
NEC Confidential
RADIO CONFIGURATION (2 of 4) 3
Enter the radio parameters and TDM mapping for the Modem (Slot 01).
Specification and information of the ODU connected to the selected Modem
Green border on the Set Position section modem configuration show the selected modem
Select the channel spacing of the radio signal Select the reference Modulation of the radio signal
Select the Radio Mode, High Capacity or High System Gain
Current setup of the selected modem „s radio configuration
3
Select the number of E1 channels to be used Select the number of STM-1 channels to be used (need STM-1 optional Interface card ) Show the available Ether bandwidth after E1 and STM-1 traffic mapping. Enter TX/RX point frequency within the Start and Stop frequency of the ODU shown above. Enter the radio signal Frame ID (1 ~ 32)
When four modems are mounted in (1+0) configuration
Select Radio Aggregation used or not used
NEC Confidential
Select the TX Power Control Mode. ATPC or MTPC. Parameter setting for each mode is from provisioning menu
RADIO CONFIGURATION (3 of 4) 4 5
Enter the radio parameters and TDM mapping for each of the configured Modem slots, and click Next 4
Confirmation screen shows the changes in blue background. Confirm the setting and click OK
Repeat for Modems in Slot 3 and 4 Select the Channel spacing to be used from the drop down list Select the Reference or fixed modulation to be used from the drop down list
5
Select the maximum number of E1 to be used Select whether STM-1 is to be used in the through mode Confirm the available Ether band width Set the TX & RX Frequency Select the Frame ID to be used (1 ~ 32) TX Power control mode ATPC or MTPC After changing the setting for Modem 1 and click the Next button
NEC Confidential
RADIO CONFIGURATION (4 of 4 ) Item
Parameter
Description
Channel Spacing
7/14/28/56 [MHz]
Specify the radio channel spacing
Reference
QPSK
Specify the reference
Modulation
16/32/64/128/256[QAM]
modulation from the list
Radio Mode
High Capacity High System Gain
E1 Mapping
For High Capacity:
Specify the number of E1
0 to 152 [CH] 56MHz
CH for mapping. (The
0 to 86 [CH] 28MHz
number of CH should not
For High System Gain :
exceed the limitation of
0 to 152 [CH] 56MHz
the specified modulation.)
0 to 77 [CH] 28MHz STM-1 Mapping
0 to 2 [CH]
Specify the number of STM-1 CH for mapping.
ETH Bandwidth
[Mbps]
Display the bandwidth of the ether traffic
TX RF Frequency
xxxxx.xxx [MHz]
Enter transmit frequency
RX RF Frequency
xxxxx.xxx [MHz]
receive frequency (automatically)
Frame ID
1 - 32
Set frame ID
TX Power Control
MTPC/ATPC
Set transmit power control mode
Radio Traffic
Not used/ Radio GRP 1
Radio aggregation usage
Not used/ Radio Group1
Radio aggregation
/Radio Group2/ radio
groups depend on the No.
Group n
of modems mounted
Aggregation
Modem radio configuration
NEC Confidential
AMR Configuration (1 of 4)
Set the AMR Modulation for Modem Slot indicated by the green border. Click Next to set the AMR priority traffic for Modem 1 & Click Next to set the next modem
NEC Confidential
AMR Configuration (2 of 4) Set the AMR Modulation for Modem Slot1 indicated by the green border. Click Next
1 2
3
Show the current Configuration for Modem 1 and 2
Item
Set the AMR priority traffic for Modem 1 & Click Next to set the next modem
Parameter
E1
QPSK
Mapping
16 QAM 32 QAM
- E1 Mapping (Range: 0 - 152)
64 QAM
- STM-1 Mapping (Range: 0 -2)
128 QAM 256 QAM
NEC Confidential
Select following items.
- ETH Bandwidth is calculated from E1 and STM-1 mapping
AMR CONFIGURATION (3 of 4)
Select AMR Operation by clicking the AMR Mode radio button. Select Non Operation radio button not to use the AMR function
Select the other modulations to be used during AMR operation by selecting the appropriate Used radio button Reference Modulation selected in Equipment Setup is shown highlighted in green. Click the Next button to set the E1 / STM-1 mapping.
E1/STM-1 Mapping Settings: Priorities for preservation of traffic (E1/STM1/Ethernet) as modulation level (and therefore transmission capacity) decreases Enter the priority E1 channels to be used for each modulation during the AMR operation in E1 Mapping for each modulation If STM-1 through mode is used select which modulation schemes to be used during AMR operation provided that the radio capacity is available. Capacity remaining for Ethernet bandwidth is shown automatically. Click the Next button to set the AMR operation and E1/STM-1 mapping for the Next Modem NEC Confidential
AMR CONFIGURATION (4 of 4)
Click the Next button to set the AMR operation and E1/STM-1 mapping for the Next Modem
NEC Confidential
NETWORK MANAGEMENT
NEC Confidential
GENERAL SETTING 1
Select General Setting from the Network Management Configuration Menu. NE Primary IP Setting is displayed
2
1
Item
Parameter
2
Click the Setup icon, General Setting window opens.
3
Enter the Primary IP address for the NE (Bridge1), Subnet Mask, and Default Gateway for the Bridge1. See the table for details
Description
IP Address Setting (Bridge 1)
IP Address
x.x.x.x
Input Primary IP Address of NE
Subnet Mask
x.x.x.x
Input Subnet Mask
Default Gateway
x.x.x.x
Input Default Gateway IP address
NMS Port Setting Connect NMS Port to
Yes
Use NMS Port
NMS
No
Not use NMS Port 3
NEC Confidential
GENERAL SETTING (DETAIL) 1 of 5 1
1
Select General Setting (Detail) from the Network Management Configuration Menu. General Setting Detail screen opens showing the network parameter setting
NEC Confidential
GENERAL SETTING (DETAIL) 2 of 5 2
To change Network parameters, Click the Setup icon, General Setting (Detail) window opens
After changing/ modifying the parameters click OK button 3
NEC Confidential
GENERAL SETTING (DETAIL) 3 of 5 Item
Parameter
Description
NE2 Port Setting NE2 Port IP Address x.x.x.x
Input IP Address of NE2 port
NE2 Port Usage
Used
Use NE2 port
Not Used
Not use NE2 port
9600
specify the line speed of NE2 port2
NE2 Port Speed
19200 Inband Management VLAN Setting Inband Management Used
Use Inband Management VLAN
VLAN Usage
Not Use
Not use Inband Management
VLAN ID
1 to 4094
VLAN ID for Inband Management
CoS
0 to 7
Class of service priority setting for inband VLAN
IP Address
x.x.x.x
Enter IP address and subnet mask for
Subnet Mask
x.x.x.x
Inband Management
Ethernet Port Setting Usage Auto Negotiation
Used
Use Ethernet port
Not Used
Not use Ethernet port
Enable
enable the Auto Negotiation of Ethernet port
Disable
Disable the Auto Negotiation of Ethernet port
Discovery Usage
Used
search of the network access machinery
Not Used
using Ethernet connect
NE Branch Setting Branch Number
1 to 6 Branches
Select the Branch Number
Default Gateway
x.x.x.x
Input the Default Gateway
LCT Port Setting NMS Port Setting
Connect NMS Port to NMS
Yes
Use NMS Port
No
Not use NMS Port
Restrict LCT
Any
Connection
Only to Local NE only connection from Local to LCT Port
NEC Confidential
Connection from Local/Remote to LCT Port
GENERAL SETTING (DETAIL) 4 of 5 When NE2 port is used for serial connection to other PASOLINK configure this NE2 Port Setting. NE2 is available from AUX-A card
Select In-band Management VLAN Setting Enter the In-Band VLAN ID and In-Band port IP Address and Subnet Mask Item
Parameter
Description
Inband Management VLAN Setting
Select usage of NMS and NE1 ports set the port parameters accordingly
VLAN ID
1 to 4094
VLAN ID of Inband Management VLAN
Inband management
Used
Use Inband management VLAN
VLAN usage
Not Used
Not use inband management function
IP Address
x.x.x.x
Enter IP address of inband management port
Subnet mask
x.x.x.x
enter subnet mask for inband management
NE1 port can be used as a Management Port or User Port. When used as the Management Port, it is can be used for LAN back-to-back purpose. When selected as User port, it is used as FE Port1 for user traffic.
NEC Confidential
GENERAL SETTING (detail) 5 of 5 Select the number of branches the NE belongs to
Enter the Bridge 2, IP address and Subnet Mask Select to which branch NMS port belongs to
Select to which branch Modem-2 port belongs to NEC Confidential
NMS IN-BAND CONNECTION 1. Select Used radio button to use Inband management function. 2. Enter the VLAN ID to be used for NMS packets. (select a VLAN ID that is not used for traffic.) 3. Enter the IP address and subnet mask for the port used for In band management. Should be from the external network different from the Radio network 4. Connect the DCN to a traffic port in iPasolink 200/400/1000
Different Subnet
Same Subnet
Main Traffic port
In-band / Out-band management NETWORK-1
NETWORK-2 Main Traffic port PNMSj / MS5000
Main traffic SV traffic
Main Traffic port NE1/NMS Port
192.168.1.0/24 In-band (Main traffic)
NEC Confidential
NE1/NMS Port
172.18.0.0/24 Out-band
ROUTING SETTING
NEC Confidential
IP ACCESS CONTROL SETTING – Input Filter List Modify Rule This function is used as an Access Control List
Delete Entry
ADD Input Filter Entry
Modify Input Filter Entry
NEC Confidential
IP ACCESS CONTROL SETTING – Input Filter List
ADD Input Filter Entry
Enter the Entry Number Enter the Input Index. Select accordingly Enter the Source IP Address Enter the Source Subnet Mask
Enter the protocol to be permitted or deny If the protocol is Other , port number Destination Port select Any or Enter the port
Select the Action Permit or Deny for a server with this address to permit or deny access.
NEC Confidential
IP ACCESS CONTROL SETTING–Forwarding Filter List
ADD Input Filter Entry
NEC Confidential
PROVISIONING
NEC Confidential
MODEM FUNCTION SETTING
NEC Confidential
MODEM PORT SETTING
Select Modem Function Setting on the provisioning menu and click on the Modem Port setting. Click MODEM(Slot01), MODEM (Slot02) or MODEM(Slot03) to open the Modem port name setting window Enter the Modem Port Name ( 32 Characters) Click the OK button to close the window
NEC Confidential
RADIO SWITCH SETTING (1 of 2) Select provisioning menu and click on the Radio Switch setting to enter the switch setting for (1+1) configuration. Click the SW GRP1 (Modem 1/2) to open the switching parameter setting dialog box. Following functions can be set by this item. TX & RX switching priority TX Switch Lock in Usage TX Switch Reverse function RX Switch condition early warning
Item
Parameter
Description
TX SW Priority
Non
Selecting non revertive mode
Priority No.1
Select No.1 when both No.1 and No.2 are normally operating.
TX SW Lockin
Used
enable TX SW Lockin function
Usage
Not Used
disable TX SW Lockin function
TX SW Reverse
Used
enable Reverse Function
Function Usage
Not Used
disable Reverse Function
RX SW Priority
Non
Selecting non revertive mod
Priority No.1
Select No.1 when both No.1 and No.2 are normally operating.
NEC Confidential
RADIO SWITCH SETTING (2 of 2) TX & RX SW PRIORITY (ONLY FOR HOT STANDBY) NON PRIORITY: SELECT THIS FOR NON HOMING SWITCHING. PRIORITY NO.1: SELECT THIS FOR HOMING SWITCHING. WHEN BOTH CHANNELS ARE NORMAL ALWAYS USE No.1 AS ONLINE. WHEN CH NO.1 FAILS SWITCH TO CH NO.2, WHEN CH NO.1 IS NORMALIZED SWITCH BACK TO CH NO.1 AUTOMATICALLY. TX SW REVERSE FUNCTION USAGE: THIS FUNCTION APPLIES TO 1+1 HOT STANDBY CONFIGURATION WITH TX SWITCH SET TO NON PRIORITY WHEN BOTH RECEIVE FAILS DUE TO OPPOSITE STATION TX MAIN ANTENNA MISALIGNMENT, AND REVERSE FUNCTION IS SET TO USED, THEN SENDS A SILENT ALARM TO TX SIDE TO SWITCH TX ODU TO STANDBY ODU. CRITERIA IS, RX LEV ALM OBSERVED FROM BOTH CHANNELS FOR MORE THAN 120 SEC. THEN SILENT ALM IS SENT TO TX SIDE TO SWITCH TX ODU TO ODU 2
NEC Confidential
TX SW LOCKIN USAGE THIS FUNCTION APPLIES TO 1+1 HOT STANDBY CONFIGURATION WITH TX SWITCH SET TO PRIORITY NO.1 IN THE CASE WHEN DUE TO INTERMITTENT ODU1 FAILURE IT SWITCHES FROM ODU1 TO ODU2 AND BACK TO ODU1 REPEATEDLY AND LOCK IN USAGE IS SELECTED USED, TX SWITCH WILL BE LOCKED TO ODU2 TO PREVENT FREQUENT SWITCHING CRITERIA IS, DURING 10MIN PERIOD IF SWITCHING OCCURS 10 TIMES, TX WILL BE LOCKED TO ODU2. IT WILL BE RELEASED AFTER 24 HOURS IF NO ALARMS ARE OBSERVED ON ODU1. RX SW CONDITION EARLY WARNING: INCLUDE EW: SELECT THIS TO INCLUDE EW AS A CRITERIA FOR AUTO REDUNDANCY SWITCHING IN (1+1) CONFIGURATION EXCLUDE EW: SELECT THIS TO EXCLUDE EW AS A CRITERIA FOR AUTO REDUNDANCY SWITCHING IN (1+1) CONFIGURATION EARLY WARNING BER SETTING IS 1E-9
TX POWER SETTING
AMR Mode
Fixed Modulation
ATPC
ATPC MODE: ATPC THRESHOLD: ENTER THE RX THRESHOLD VALUE TO BE USED WHEN OPPOSITE STATION IS IN ATPC MOD E(FIXED MODULATION) ATPC RANGE (MAX): MAXIMUM POWER LEVEL UNDER ATPC CONTROL IS DEFINED BY THIS ITEM (Set the value in dBm) ATPC RANGE (MIN): MINIMUM POWER LEVEL UNDER ATPC CONTROL IS DEFINED BY THIS ITEM (Set the value in dBm)
NEC Confidential
TX POWER SETTING
AMR Mode
Fixed Modulation
MTPC MTPC MODE: MANUAL TRANSMIT POWER CONTROL MODE MPTC TX POWER : ENTER A VALUE IN dBm WITHIN THE RANGE INDICATED ATPC THRESHOLD: ENTER THE RX THRESHOLD VALUE TO BE USED WHEN OPPOSITE STATION IS IN ATPC MODE (SET IN 1 dB STEPS) NOT IN AMR MODE
NEC Confidential
ALARM MODE SETTING
ATPC MTPC COMM ALM MODE : THIS ITEM SELECT THE ACTION TO BE TAKEN WHEN THE COMMUNICATION BETWEEN IDU AND ODU FAILS. SELECT MUTE: TO STOP TX OUTPUT POWER HOLD : TO KEEP TRANSMITTING THE TX OUTPUT POWER
ALARM MODE: ATPC POWER MODE: THIS ITEM DEFINE THE ODU TX POWER SETTING DURING ATPC CONTROL FAILURE HOLD: TO MAINTAIN THE CURRENT TX POWER AT THE TIME OF ATPC CONTROL FAILURE SELECT : MAX: TO TRANSMIT AT ATPC MAX POWER LEVEL AT THE TIME OF ATPC CONTROL FAILURE MIN: TO TRANSMIT AT ATPC MIN POWER LEVEL AT THE TIME OF ATPC CONTROL FAILURE
NEC Confidential
AMR Setting
AMR Mode: CNR + RSL
AMR Mode: CNR Under Interference condition Modulation Up C/N 33 dB + No Error C/N 30 + No Error dB 256QAM 64QAM 128QAM
AMR Switch Condition : Default setting is CNR+ RSL. Select CNR when under interference environment AMR Transition : Select Normal or Sensitive related to operation of ATPC during AMR operation
NEC Confidential
E1 / STM-1 / CROSS CONNECT SETTING
NEC Confidential
Provisioning – E1 Port setting (1 of 2) SELECT E1 PORT SETTING FROM THE PROVISIONING - E1/STM-1/ CROSS CONNECT SETTING MENU. 16E1-S TAB IS SHOWN WHEN THE OPTIONAL 16E1 CARD IS MOUNTED
CLICK THE EDIT ICON TO CONFIGURE THE E1 PORT SETTING
INDICATE THE CURRENT SETTING: E1 CHANNELS USED IMPEDANCE SETTING FOR EACH E1 CHANNEL SERVICE NAME FOR EACH E1 CHANNEL CH USAGE ERROR REPORT/NOT REPORT
NEC Confidential
Provisioning – E1 Port setting (2 of 2)
COLLECTIVE SETTING ALLOWS ALL E1 CHANNELS TO BE SET TO THE SAME CONFIGURATION USED ALL CH OR NOT USED ALL (SELECT RADIO BUTTON) CH USAGE ERROR REPORT ALL / NOT REPORT ALL (SELECT RADIO BUTTON) IMPEDANCE ALL CH 120 OHM OR ALL CH 75 OHM ( SELECT RADIO BUTTON)
CH USAGE :- SELECT E1 CHANNELS TO BE USED BY SELECTING THE USED RADIO BUTTON. NOT USED RADIO BUTTON INHIBIT ALARMS FROM THE SELECTED CHANNEL
CH USAGE ERROR REPORT:- SELECT REPORT RADIO BUTTON TO RAISE AN ALARM WHEN AN E1 SIGNAL IS DETECTED AT HE INPUT OF A CHANNEL SELECTED AS NOT USED E1 PORT IMPEDANCE:- SELECT THE IMPEDANCE OF THE E1 CHANNELS TO BE 120 OHMS OR 75 OHMS. SELECT THE APPROPRIATE RADIO BUTTONS. SERVICE NAME:- ENTER THE SERVICED NAME FOR EACH E1 CHANNEL. (MAX 32 CHARACTERS)
NEC Confidential
Provisioning – STM-1 Port setting (1 of 6) SELECT STM-1 PORT SETTING FROM THE PROVISIONING - E1/STM-1/ CROSS CONNECT SETTING MENU CLICK THE EDIT ICON TO OPEN THE STM-1 PORT SETTING WINDOW
NEC Confidential
Provisioning – STM-1 Port setting (2 of 6) WHEN STM-1 IS SELECTED AS THROUGH MODE
NEC Confidential
Provisioning – STM-1 Port setting (3 of 6) Item
Parameter
Description
STM-1 Mode
Through
Through Mode of STM-1
Channelized
Channelized Mode of STM-1
Used
use STM-1 Port
Port Usage
Not Used
not user STM-1 Port
Port Name
1 to 32 character
specify the port name of the STM-1
MS - AIS Generation
Enable
enable device stop output laser when receiving STM1 signal lost (optical or radio) (RLOS) and send out MS-AIS.
Disable
disable device stop output laser when receiving STM1 signal lost (optical or radio) (RLOS) and send out MS-AIS
ALS Usage ALS Interval
Enable
enable ALS (Auto Laser Shutdown)
Disable
disable ALS (Auto Laser Shutdown)
60 sec
set the delay of release ALS after restored
180 sec 300 sec Trace Mismatch Detection
Disable
disable TIM detection
Enable J0
enable RS-TIM detection
Enable J1
enable HP-TIM detection
Trace Mismatch AIS Generation Action Enable
enable transmit AIS alarm when TIM detected
Disable
disable transmit AIS alarm when TIM detected
Section Trace Send
1 to 15
set J0 in transmit direction
Expected Section Trace
1 to 15
set J0 in receiving direction
High Order Path Trace
-
Not select
Expected High Order Path Trace
-
Not select
Received select trace Port 01
-
Display the received
Received High Order Path Trace
-
Not select
Received Trace Value
NEC Confidential
Provisioning – STM-1 Port setting (4 of 6) Item
Parameter
Description Radio Alarm Transfer setting
Radio Alarm Transfer
Enable
Enable alarm transfer through E1 channel when STM-1 is configured as channelized
Disable
Disable Radio Alarm Transfer function STM-1 Switch setting
Lockin Usage
Used
Enable Lockin usage to prevent frequent switching
Not used
Not use lockin usage function
Detection time (min)
1 to 60
set the interval of counting number of times for lockin
Detection Count (times)
1 to 255
Setup for the lock in threshold value of the switch over number of times
Clear lockin time (min)
-1 to 2880
Set duration od pause of switchover in the lockin condition
NEC Confidential
Provisioning – STM-1 Port setting (5 of 6) STM-1 MODE SETTING: SELECT THROUGH RADIO BUTTON TO TRANSMIT STM-1 OVER THE RADIO FRAME SELECT CHANNELIZED RADIO BUTTON TO EXTRACT THE 63 E1 FROM THE STM-1. AND SELECTIVELY USE THEM.
PORT SETTING: PORT USAGE: SELECT USED TO USE THE STM-1 PORT OR NOT USED TO NOT SELECT THE STM-1 PORT. SELECT THE APPROPRIATE RADIO BUTTON. PORT NAME: ENTER A NAME FOR THE STM-1 CHANNEL (MAX 32 CHARACTERS)
MS-AIS GENERATION SETTING IS USED TO STOP SENDING MS-AIS SIGNAL DUE TO RADIO LINK OR EQUIPMENT FAILURE. WHEN DISABLED:- DURING FAILURE OPTICAL INTFC WILL STOP TRANSMITTING THE OPTICAL SIGNAL, ELECTRICAL INTFC WILL SEND UNFRAMED AIS. WHEN ENABLED:- SEND MS-AIS DUE TO RADIO LINK OR EQUIPMENT FAILURE.
AUTOMATIC LASER SHUT DOWN (ALS) FUNCTION IS AVAILABLE ONLY FOR OPTICAL INTFC . DURING LOS OF SIGNAL AT THE INPUT OF THE OPTICAL INTFC IT WILL CUT THE LASER OUTPUT FROM THE OUTPUT OF THE OPTICAL INTFC. DURING THIS TIME AT DEFINED INTERVALS INTFC WILL OUTPUT A 2 SEC LASER PULSE. SELECT ENABLE OR DISABLE FROM THE ALS FUNCTION RADIO BUTTON IF ENABLE IS SELECTED, SELECT ALS INTERVAL FROM 60, 180, AND 300 SEC .
NEC Confidential
Provisioning – STM-1 Port setting (6 of 6 ) TRACE SETTING: ENABLE OR DISABLE J0 OR J1 TRACE MIS MATCH DETECTION WHEN TRACE MISMATCH IS DETECTED WHETHER TO ENABLE OR DISABLE AIS GENERATION ENTER THE TX TRACE PATTERN ENTER THE EXPECTED RX TRACE PATTERN
TRACE SETTING: WHEN HIGHER ORDER PATH TRACE IS ENABLED ENTER THE HO PATH TRACE PATTERN AND THE EXPECTED RX PATTERN
NEC Confidential
STM-1 Port setting APS Group (400/1000)
NEC Confidential
CROSS CONNECT SETTING
NEC Confidential
Provisioning – Cross connect setting
NEC Confidential
Provisioning – Cross connect setting – E1 1
1 Click Add icon in the cross connect setting screen to open the Cross 2
2
3
4
5
3
4
5
6 6
NEC Confidential
connect setting (Add) window. Service Number: Each cross connection is given a unique service number. Enter the service number. Service Name: Each cross connection can have an optional service name giving information of the connection. Enter the service name. Cross connect type : To map cross connection of E1 channels from main-board, optional 16E1 board or from the channelized STM-1 board select E1 radio button. Cross connection mapping is made from Edge-A to Edge –B. select one side of the connection as Edge-A and the other side as Edge-B. Click the EDGE-A drop down arrow and select the board or modem for the connection. From the available E1 list select the E1 channel for the start connection. Click the Edge-B drop down arrow and select the board or modem for the connection. From the available E1 list select the E1 channel for the end connection. Click the OK button. Repeat the procedure for each connection. Each connection will appear in the Cross Connect Setting screen.
Provisioning – Cross connect setting STM-1 (Through)
1
1 Click Add icon in the cross connect setting screen to open the Cross 2 3
2
4
5
3
4
5
6 6
NEC Confidential
connect setting (Add) window. Service Number: Each cross connection is given a unique service number. Enter the service number. Service Name: Each cross connection can have an optional service name giving information of the connection. Enter the service name. Cross connect type : To make a STM-1 connection in through mode select STM-1 (Through) radio button. Cross connection mapping is made from Edge-A to Edge –B. select one side of the connection as Edge-A and the other side as Edge-B. Click the EDGE-A drop down arrow and select the STM-1 board or modem for the connection. From the available STM-1 list select the STM-1 Port for the start connection. Click the Edge-B drop down arrow and select the STM-1 board or modem fro the connection. From the available STM-1 list select the STM-1 Port for the end connection. Click the OK button. Repeat the procedure for each connection. Each connection will appear in the Cross Connect Setting screen.
Provisioning – Cross connect setting
Item
Parameter
Description
No
1 to 168
Cross Connect Service Number
Service Name
0 to 32 characters
Cross Connect Service Name
Cross Connect Type
E1
E1 level Cross Connect
STM-1 (Through)
STM-1 level Cross Connect
Protection
Check the radio box
If Protection is checked, Edge .A Term 2 need to be specified.
Edge .A Term 1
ifIndex Slot-Port-CH
Edge .A Term 2
ifIndex Slot-Port-CH
Edge. A Protection
Edge .B Protection Protection
Check the radio box
Edge B Term 1
ifIndex Slot-Port-CH
Edge .B Term 2
ifIndex Slot-Port-CH
If Protection is checked, Edge. B Term 2 need to be specified.
NEC Confidential
Cross Connect - SNCP
Edge B SNCP
Modem-1 Dir-A
16xE1
Edge A
NEC Confidential
Modem-2 Dir-B
Cross Connect - SNCP 1 1
2
2
2 3 4 3
5
4 5
6
6
7
7
NEC Confidential
Service Number: Enter the service number. Service Name: Enter the Service Name Cross connect type : Cross connect Type for SNCP is only E1. select E1 Radio Button. Click the EDGE-A drop down arrow and select the board or modem for the SNCP connection. From the available E1 list select the E1 channel for the start connection. Select the Edge-B Protection Check Box. The lower setting for the Edge –B become active Click the Edge-B upper section drop down arrow and select the board or modem for working path connection. From the available E1 list select the E1 channel for the work side end connection. Click the Edge-B Lower section drop down arrow and select the board or modem for Protection path connection. From the available E1 list select the E1 channel for the protection side end connection Click the OK button. Repeat the procedure for each SNCP connection. Each connection will appear in the Cross Connect Setting screen. Online column show which path is online and offline.
Cross Connect – Modify / Delete
Click on the Service number of the cross connection to be modified Modify the connection as required and click OK
Click on the Delete icon. Open the Cross Connect Setting (Delete) window. Enter the Service Number of the Cross connection to be deleted. Click the OK button and click OK on the Confirmation and Complete dialog boxes.
NEC Confidential
Cross Connect – Delete
To delete selected cross connections, click the check box of the service nos. to be deleted. To delete all cross connections, click the check box on top.
NEC Confidential
Cross Connect – Modify
Click on the Service number of the cross connection to be modified
Modify the connection as required and click OK
NEC Confidential
Cross- connect – AMR Linkage Click on the AMR Linkage, to see how the TDM channels are dropped during the modulation change from Higher Modulation to lower modulation. TDM mapping shown is set from the Radio Configuration.
Radio E1 CH No. Highest CH no. in the radio frame will drop first during AMR operation
Priority E1 channels during AMR operation NEC Confidential
Pseudo Wire Emulation
NEC Confidential
PWE-Setting Expand the provisioning menu and click on the PWE Setting. PWE setting window for the MSE card appears showing the current PWE setting.
Click on the Detail for any PWE No. to see the detail information for the selected PWE No.
Click the Add PWE icon to open the PWE Setting wizard
Click on the PWE No. to open the PWE Modifying wizard
NEC Confidential
PWE Setting – Wizard Step1 1
7
1
Click Add PWE icon on the PWE Setting screen. Step 1 of the PWE setting wizard opens
2
Enter the PWE No. value between (1 ~ 256)
3
Enter the PWE Service Name
4
Click the MSE E1 CH drop down list and select the MSE E1 channel number for this connection
2 3
4
5
Click the Jitter Buffer drop down arrow and select the size of the jitter buffer in mili seconds
6
Click the Clock Mode drop down arrow and select the clock mode. For master side select NE clock or Sync E1. for the slave side select ACR (Adaptive Clock Recovery)
7
Click the Detail Option icon to open the detail option setting screen. Select Capsule E1 Frame Size (1 to 8 Frames)
8
To use the Real-time Transport Protocol (RTP) select the ON radio button. Default is off. Click OK button to close the Detail Option window
9
Click next to go to PWE wizard Step2
6
5
7 8
9
NEC Confidential
PWE Setting – Wizard Step2 10
Enter the Class of Service (CoS) Priority levels for the PWE packets
11
Enter the Unique Emulated Circuit Identifier (ECID) number for the PWE circuit
12
Enter the Destination MSE Card MAC Address
13
Select the radio button of the VLAN ID for the Packets sent out for this PWE circuit.
14
If the required VLAN ID is not in the list, click the Add VLAN ID icon. From the add VLAN ID window enter the VLAN ID and VLAN Service name Click ok to add the VLAN to the VLAN list.
15
Click the Next button to got the PWE Wizard Step3 Setting Confirmation window
14 10 11 12
13
14
15
NEC Confidential
PWE Setting – Wizard Step3
16 17
NEC Confidential
16
Confirm the setting for this PWE circuit and click OK. If not click Back and change the setting.
17
Confirm that the PWE circuit is listed.
PWE Setting – Cross-connect 1
To assign E1 from Main board or other 16E1 card to the MSE-A card. Select the cross connect setting menu.
2
2
Click Add , from the cross connect (Add) window. Assign the E1 channels to the MSE-A card created PWE channels.
NEC Confidential
EQUIPMENT CLOCK/ SYNCHRONIZATION
NEC Confidential
Provisioning – Clock/Synchronization
SELECT EQUIPMENT CLOCK FROM THE PROVISIONING EQUIPMENT CLOCK / SYNCHRONIZATION SETTING MENU CURRENT EQUIPMENT CLOCK MODE AND SELECTED CLOCK SOURCE IS INDICATED. CLICK THE Modify ICON TO SET / CHANGE EQUIPMENT CLOCK SETTING AFTER SELECTING THE EQUIPMENT CLOCK SETTING CLICK THE OK BUTTON CLICK OK BUTTON ON THE TIMING LOOP WARNING DIALOG BOX
NEC Confidential
Provisioning – Clock/Synchronization Select Master radio button for Internal clock
Select Slave radio button for select from Clock sources
Select PL Mode radio button to use Priority Level for selecting the timing source Select QL Mode radio button to use clock Quality Level for selecting the timing source
NEC Confidential
Synchronization method iPASOLINK can utilize multiple clock sources. Synchronous Ethernet
Modem-1 Modem-2 E1 Line CLK Option Line CLK(STM1) GbE Line CLK
Timing Source 1
S E L
Timing Source 2 Timing Source 3
S E L
PLL
SDHLine Transmit Clk
PDHLine Transmit Clk Radio Clk Output G.703 External Clk Output
SEL External CLK OUT 1000 External Clock
External CLK IN
1 2 SSU Synchronization Source Unit
1000 External Clock
NEC Confidential
Synchronize external equipment
Provisioning – Clock/Synchronization EQUIPMENT CLOCK MODE: SELECT THE CLOCK MODE TO BE USED IN THE IDU. SELECT MASTER (internal CLK) OR SLAVE (synchronization) RADIO BUTTON AS APPLICABLE
SyncETH: ENABLE OR DISABLE THE SYNCETH FUNCTION. WHEN ENABLE SYNCETH CLK CAN BE RECEIVED OR SENT OVER THE GbE LINE
THREE TIMING SOURCES CAN BE SELECTED . AVAILABLE TIMING SOURCES DEPENDS ON THE OPTION CARDS MOUNTED. NO. 1 AND 2 CAN SELECT FROM THE FOLLOWING SOURCES: IF E1 CHANNELS ARE USED E1 LINE CLOCK IS AVAILABLE AS A TIMING SOURCE (select from CH1 to CH16) IF STM-1 CARD OPTION IS USED IN CHANNELIZED MODE THEN OPTION LINE CLK (STM1 CAN BE USED AS A TIMING SOURCE. IF STM-1 IS USED IN THROUGH MODE IT IS NOT AVAILABLE AS A TIMING SOURCE. MODEM (Slot#) CAN BE SELECTED AS A TIMING SOURCE
WTR : SET WAIT TO RESTORE TIME, WHICH IS THE AMOUNT OF TIME TO WAIT BEFORE A RECOVERED TIMING SOURCE BECOMES ACTIVE AGAIN. (0 THRU 15 MIN)
NEC Confidential
Clock/Synchronization – EXT Clock Setting
NEC Confidential
Clock/Synchronization – EXT Clock Setting Item
Parameter
Description
EXT
120 Ω
set Ext Clock impedance to 120 Ω
Impedance
70 Ω
set Ext Clock impedance to 75 Ω
EXT CLK
bps
select the Ext Clock in bps
Interface
Hz
select the Ext Clock in Hz
CRC
On
turn on Ext Clock CRC check
On/Off
Off
turn off Ext Clock CRC check
SSM
Enable
Support Disable Sa Bit
Sa4 to Sa8
EXT CLK
NOT
Out SEL
SELECT
CLK out not used
NE CLK
Use NE CLK
DMR Line
Use DMR Line CLK1
CLK 1 DMR Line
Use DMR Line CLK2
CLK2
GbE Line Item
Parameter
SLOT
01-14
Port /CH
E1 (1-16) CH
Description
E1 Line Specify port / CH
Option
STM-1
Line CLK
On/OFF
Threshold AIS Generation Mode
ON /OFF
AIS Generation Mode
AIS / Shutdown
Timing Loop Prevention
ON/OFF
NEC Confidential
Use E1 Line CLK
CLK
GbE (1-6) Message Pass through
Use GbE Line CLK
CLK
Use Option Line CLK (STM-1)
RELAY-ALARM MAPPING SETTING
NEC Confidential
Provisioning – Relay-Alarm Mapping (W/O AUX Card)
NEC Confidential
Provisioning – Relay-Alarm Setting (W/O AUX card)
NEC Confidential
Relay Alarm setting with AUX card (1 of 2)
When AUX Card is mounted additional four relays are available for: Alarm Relay assignment For Cluster alarm output. For House Keeping Output control
Click on the tabs Main Board, ODU No.1/Modem(Slot01), ODU No.2/Modem(Slot02) , 16E1-A to display the current relay alarm assignments. Click the Modify icon to change the relay –alarm assignment of each tab for parallel alarm out.
NEC Confidential
Relay Setting for AUX out put
Select the AUX-A tab to see the current assignment of Relays for House Keeping Control and Cluster Alarm Out. Click the Modify icon to open the Relay Control setting window for AUX –A, Assign Relays for House Keeping Control and Cluster Alarm Out. Make sure that HK Out and Cluster Alarm out are not assigned to the same relay
NEC Confidential
Provisioning – Cluster Alarm
NEC Confidential
AUX SETTING
NEC Confidential
AUX Input Setting (1 of 2)
Name: Enter the name for the alarm (32 Characters) Condition: Select from the drop down list alarm input condition Alarm when Event ON (close): [Report when Alarm is ON]
Click on the tab to select the AUX input to be set or modified
Alarm when Event OFF (Open): [Report when alarm is OFF]
Click on the Modify icon to open the AUX input Setting for AUX#
Status : Event is considered as a Status Event not alarm event Status String: Enter the text to be shown when the Event is ON and OFF (32 Characters) Status String: Enter the text to be shown when the Event is ON and OFF (32 Characters) X.733: Select the Severity, Alarm Type and Probable cause for the event from the drop down list for each item Click OK button to close the window
NEC Confidential
AUX Input Setting ( 2 of 2)
NEC Confidential
AUX Output Setting (2 of 2) Expand Provisioning from LCT menu. Expand AUX Setting from Provisioning sub menu. Select AUX Output Setting from AUX Setting sub menu. AUX Output Setting window opens indicating the status of the four output controls.
Click the required Output # to configure the output or apply the output control. Name: give a name to the output control (1-32 characters) Control: Select Event Off or Event on radio buttons, to specify the type of output control for the selected relay Status Strings: enter the status strings to appear when the event is ON and when the event is OFF
Click OK button to apply the output control for the selected relay.
Select the AUX tab from the current status display. To see the status of Housekeeping input alarms and Housekeeping control out .
NEC Confidential
V.11 / OW SETTING
NEC Confidential
SERVICE CHANNELS / OW
Through
2 x RS 232C 2 x V.11 STM-1INTFC E1, F1, DCCr OW
iPASOL INK 3 x RS 232C USER 3 x V.11 iPasolink1000 CHANN ELS
DSC 1 ~ DSC 4
2x RS 232C 2 x V.11 STM-1INTFC E1, F1, DCCr OW
iPASOL INK 3x RS 232C 3 x V.11 USER iPasolink1000 CHANN EL
NEC Confidential
PDH DSC 1 ~ DSCRADIO 4 OH
2 x RS 232C 2 x V.11 STM-1INTFC E1, F1, DCCr OW
iPASOL INK 3 x RS 232C USER 3 x V.11 iPasolink1000 CHANN ELS
V.11 / SC SETTING 1of 3 Click the SC Channel , and Modem1 /2 to assign the related service channel assignments
V.11/SC setting menu provides the configuration of user interface (V.11, RS-232C) and OW channel.
User CH to SC setting STM-1A is available when the STM-1 port is used as channelized. Select to assign E1 ,F1 and DCCr to Service channels over the radio
SC through setting
NEC Confidential
V.11 / SC SETTING 2 of 3 Expand Provisioning from LCT menu. Expand V.11/OW Setting from Provisioning sub menu. Select V.11/SC Setting from V.11/OW Setting sub menu. V.11/SC Setting window appears. Click SC Channel
Example: To assign user channel RS-232-C Ch1 to modem-(Slot01)1 SC1 Select Modem (Slot01) from the Item drop down list Click on the rectangle intercepting the RS-232C-1 row and SC1 column, assignment is indicated by the green color. Similarly to assign the user channel V.11 Ch1 to modem-1 SC2 Click on the rectangle intercepting the V.11-1 row and SC2 column, assignment is indicated by the green color. Click OK to set the assignment Confirm the assignment in Provisioning-V.11/OW setting – V.11/SC setting window
NEC Confidential
V.11 / SC SETTING 3 of 3
Example: To assign Modem (Slot02) , SC3 through to modem (Slot01)1 SC-3 Click Modem (Slot01) in the Provisioning –V.11/OW Setting-V.11/SC Setting window Select Modem (Slot02) from the Item drop down list Click on the rectangle intercepting the SC-3 row of Modem (Slot01) and SC3 column , assignment is indicated by the green color. Click OK to set the assignment Confirm the assignment in Provisioning-V.11/OW setting – V.11/SC setting window
NEC Confidential
V.11 Directional Setting
Current Direction setting
Expand Provisioning from LCT menu. Expand V.11/OW Setting from Provisioning sub menu. Select V.11 Directional Setting from V.11/OW Setting sub menu. V.11 Directional Setting window appears
Click the radio button Co-Directional or Contra-Directional as appropriate. Click the OK Button Item
Parameter
Description
V.11-1/2 Direction Setting
Co-Directional
the data receiving direction is same as the clock output /input direction
Contra-Directional
the data receiving direction is different from the clock output/input direction
NEC Confidential
OW SETTING
Current Order Wire setting
Expand Provisioning from LCT menu. Expand V.11/OW Setting from Provisioning sub menu. Select OW Setting from V.11/OW Setting sub menu.
Click the Modem (Slot01) or Modem (Slot02) to open the OW Setting (Modem (Slot#) 1+0) window
Select Used radio button to enable DSC channel for OW Select Not Used radio button to disable DSC channel for OW Click the OK Button
Click the AUX-A to open the OW Setting (AUX-A) window Select Invert radio button if the back-to-back call signal polarity is inverted Select Normal radio button to if the back-to-back call signal polarity is normal Click the OK Button
NEC Confidential
ALARM / AIS SETTING
NEC Confidential
CORRELATION SETTING
From the Provisioning menu. Select Alarm/AIS Setting sub menu Select Correlation Setting from Alarm/AIS Setting sub menu. Correlation Setting window appears. Click Edit button.
Select the Alarm correlation ON radio Button to enable masking lof over level alarms Select the Alarm correlation OFF radio Button to disable masking of lover level alarms Click OK button and to set the changes.
Item
Parameter
Description
Alarm
On
enable mask the lower level alarm
Correlation
Off
disable mask the lower level alarm
NEC Confidential
AIS Setting AIS setting function allows to change the behavior when the AIS signal is received, activated and whether to report or not to report the AIS alarms .
Item
Parameter
Description
AIS Activation
LOF + High BER
sending AIS alarm after received
Condition
LOF and High BER alarm LOF
sending AIS alarm after received LOF alarm only.
AIS Generated
Report
report AIS generated event
Report
Not Report
do not report AIS generated event
AIS Received
Report
report AIS received event
Report
Not Report
do not report AIS received event
AIS Received
Alarm
specify the AIS received event as
Condition
an alarm event Status
specify the AIS received event as a status event
NEC Confidential
Alarm Severity Setting-1
Expand Provisioning from LCT menu. Expand AUX Setting from Provisioning sub menu. Select AUX Input Setting from AUX Setting sub menu. AUX Input Setting window appears. Click the tabs to see the current setting for each AUX input.
NEC Confidential
Alarm Severity Setting-2 TCN STM1
MOD EM
AUXA
FAN
NEC Confidential
Alarm Severity Setting-3 STM1
E1
GbE
MSE
TER M PS
NEC Confidential
MCM
PMON / RMON Setting
NEC Confidential
Provisioning – PMON / RMON Setting
NEC Confidential
Provisioning – PMON / RMON Setting
NEC Confidential
Provisioning – PMON / RMON Setting
NEC Confidential
Provisioning – PMON / RMON Setting
NEC Confidential
MAINTENANCE CONTROL
NEC Confidential
LOOPBACK CONTROL
NEC Confidential
MAINT Control- Modem Loopback IF loopback cuts the TX output affecting the radio link
If Maintenance mode is selected before applying the maintenance control “ Switch to Maintenance mode first error message appears
Parameter IF Loopback
Off
Turn on the IF Loopback function (Default)
On
Turn off IF Loopback function
Release Time not release
Not set automatic restore
90 sec (Default)
Set automatic restore time
180 sec
* Available when executing IF Loopback from remote NE.
300 sec 3600 sec (60 min) 43200 sec (12h)
NEC Confidential
MAINT Control- TDM Loopback1 This is the Near End Baseband Loopback
Click on Maintenance button on the top of LCT window to enter maintenance mode. Expand the Maintenance Control from LCT menu。 Expand the Loopback Control from Maintenance Control sub menu. Select the TDM Loopback Control (E1 LB1) from Loopback Control sub menu. TDM Loopback Control (E1 LB1) Window is displayed
Click on Off of the Main Board selected CH# field to open the TDM Loopback Control (E1 LB1) Select E1 LB1 CH# ON radio button to select loopback On. Click OK button to apply the maintenance control. Off indication will turn to On with Yellow background
NEC Confidential
MAINT Control- TDM Loopback2 This is the Far End Baseband Loopback
Click on Maintenance button on the top of LCT window to enter maintenance mode. Expand the Maintenance Control from LCT menu。 Expand the Loopback Control from Maintenance Control sub menu. Select the TDM Loopback Control (E1 LB2) from Loopback Control sub menu. TDM Loopback Control (E1 LB2) Window is displayed
Click on Off of the Main Board selected CH# field to open the TDM Loopback Control (E1 LB2) Select E1 LB2 CH# ON radio button to select loopback On. Click OK button to apply the maintenance control. Off indication will turn to On with Yellow background
NEC Confidential
MAINT Control- TDM Loopback2 This is the Far End Baseband Loopback
Click on Maintenance button on the top of LCT window to enter maintenance mode. Expand the Maintenance Control from LCT menu。 Expand the Loopback Control from Maintenance Control sub menu. Select the TDM Loopback Control (E1 LB2) from Loopback Control sub menu. TDM Loopback Control (E1 LB2) Window is displayed
Click on Off of the Main Board selected CH# field to open the TDM Loopback Control (E1 LB2) Click OK button to apply the maintenance control. Off indication will turn to On with Yellow background
NEC Confidential
MAINT Control- STM-1 Loopback1 This is the Near End Baseband Loopback
Click on Maintenance button on the top of LCT window to enter maintenance mode. Expand the Maintenance Control from LCT menu。 Expand the Loopback Control from Maintenance Control sub menu. Select the TDM Loopback Control (STM-1 LB1) from Loopback Control sub menu. TDM Loopback Control (STM-1 LB1) Window is displayed
Click on Off of the STM-1S field to open the TDM Loopback Control (STM-1 LB1) Select ON radio button to select loopback On. Click OK button to apply the maintenance control. Off indication will turn to On with Yellow background
NEC Confidential
MAINT Control- STM-1 Loopback2 This is the Far End Baseband Loopback
Click on Maintenance button on the top of LCT window to enter maintenance mode. Expand the Maintenance Control from LCT menu。 Expand the Loopback Control from Maintenance Control sub menu. Select the TDM Loopback Control (STM-1 LB2) from Loopback Control sub menu. TDM Loopback Control (STM-1 LB2) Window is displayed
Click on Off of the STM-1S field to open the TDM Loopback Control (STM-1 LB2) Select ON radio button to select loopback On. Click OK button to apply the maintenance control. Off indication will turn to On with Yellow background
NEC Confidential
PROTECTION CONTROL
NEC Confidential
Protection Control- TX/RX SW Control
TX and RX switch status is indicated below the controls.
TX / RX SW MANUAL CONTROL This menu items are active in (1+1) configuration (Under Maintenance Mode) TX SW menu is available for (1+1) hot standby configuration only. Normal operation is „Clear” mode. Select Manual No.1 or Manual No.2 and click OK to select the TX channel manually. (TX switching interrupt the traffic momentarily Lock-in Control menu is available for any (1+1) configuration. Normal operation is “OFF “mode. Select Lock-in Control “OFF” indication to open the Lock-in Control window. Select No.1 Lock-in or No.2 Lock-in. Click the OK button to apply the selected channel to Lock-in mode
NEC Confidential
Protection Control- TX/RX SW Control
RX SW MANUAL CONTROL This menu item is active in (1+1) configuration RX SW menu is available for any (1+1) configuration. Normal operation is “Clear “mode. Select manual No.1 or No.2 if the channel to be switched to is normal (no alarms) Select Forced No.1 or No.2, if the channel to be switched to is in alarm condition and need to switch forcibly. Click OK button to select the RX channel manually. Selected control mode is shown in a yellow back ground indicating the control is under maintenance mode.
NEC Confidential
Protection Control- RSTP Control
Select RSTP Control under the Maintenance Protection Control menu. Protection Control- RSTP Control screen display current RSTP status Click the RSTP Clear icon, to initialize the RSTP process. Click the OK button on the warning dialog box to continue the RSTP clear control.
NEC Confidential
Protection Control- SNCP SW Control Select SNCP Switch Control under the Maintenance Protection Control menu. Protection Control-SNCP Switch Control screen display the SNCP connections and Online and offline status
To manually switch any SNCP connection, click on the Service number of the SNCP connection. SNCP Switch Control window opens giving the Working and Protection paths. Online status and Path status are also provided. Click on the SNCP Manual SW Control drop down arrow and select the control to be applied. Click OK, and OK again on the warning dialog. Forced SW to Protection – Switch forcibly to Protection channel even in alarm status Forced SW to Work – Switch forcibly to working channel even in alarm status Manual SW to Protection – switch to protection when it is in normal status Manual SW to Work – Switch to working when it is in normal status Clear – Clear the Maintenance Control When any Switching control is applied, the maintenance control applied status is indicated by the yellow back ground of the selected Service Number. Also the Protection Status column show the switched status forced or manual To remove the maintenance control, apply Clear control in the SNCP Manual SW control.
NEC Confidential
Protection Control- APS Switch Group Control Select APS Switch Group Control under the Maintenance Protection Control menu. APS Switch Group Control screen display current APS Group status
To manually select Working or Protection STM-1 Port. Click the APS Manual SW Control drop down list and select the option for APS switching Click on the drop down menu and select Manual SW (if the Port is normal) or Forced SW (if the port is under alarm condition) and select OK. Select Normal to release the switch control and click OK.
To remove the maintenance control, apply Clear control in the SNCP Manual SW control.
Click OK to apply the control
Status of the maintenance control is shown by the yellow background with the switched status
NEC Confidential
Protection Control- Timing Source SW Control Select Timing Source Switch Control under the Maintenance Protection Control menu. Protection Control- Timing Source Switch Control screen display current timing sources selected and switch control status and lockout status.
To Lock Out the timing source from being used as a timing source in the equipment, click the Off status under the Lock Out column for the selected Timing source. Timing Source Switch control window for lock out opens.
To manually select a timing source, click on the timing source status under the Timing Source SW control column of the open the Timing Source Switch control Window
Select the appropriate radio button ON or OFF and select OK ..
Click on the drop down menu and select Manual SW (if the timing source in normal) or Forced SW (if the timing source is under alarm condition) and select OK.
Status of the maintenance control is shown by the yellow background with the switched status
Select Normal to release the switch control and click OK.
NEC Confidential
MAINT Control- Modem Maint CTRL
ATPC Manual Control If TX Power Control Mode selected is ATPC Mode, it is possible to temporarily disable ATPC mode under maintenance control and transmit .a fixed transmit power. Select ATPC Manual Control On radio button and enter required fixed (Manual) power output level within the limits shown. Click OK button to apply the manual TX control. This may be required during antenna alignment.
NEC Confidential
MAINT Control- Modem Maint CTRL
This maintenance Control switch off the TX output power of the ODU connected to the selected modem
This maintenance Control TX an unmodulated carrier from the selected modem
This maintenance Control select a fixed modulation when the modem is under AMR mode . Select auto to go back to AMR mode starting with QPSK modulation and adjust according to the propagation condition
When TX Mute and CW Control is applied to the NE remotely, it is possible to select an automatic release timer. (these two controls interrupt the radio link) at the end of the timer value the control will be released normalizing the link NEC Confidential
MAINT Control- Laser Shutdown
The STM-1 OPT Interface is provided with Automatic Laser Shutdown Function (ALS), if disable the laser output is always ON even if the input optical cable is disconnected. When ALS function is set to enable the OPT INTFC observe the loss of signal and start a timer (550ms) and generate a control signal to interrupt the optical output . . When the fault that interrupt the optical input is cleared the system can be restored by controlling the laser output through one of the following methods. Automatic Control Manual Restart Short on time (2 sec) Maintenance Control Manual Restart Long on time (90 sec) Maintenance Control
NEC Confidential
MAINT Control- OW Buzzer Control
Oder Wire Buzzer control allows selected remote stations on a nodal configuration to be called. Select All radio button to call all the remote stations connected in the nodal configuration to be called Select the modem (slot#) radio button to call a single remote station in the nodal configuration click Execute icon to activate the Buzzer control
NEC Confidential
MAIN CARD CONTROL
NEC Confidential
H/W _ F/W RESET CONTROL
NEC Confidential
RESET Parameter
Reset CPU
L2SW
H/W Reset
Device
Program ROM Switching
Reset Main Board/CTRL
-
ODU
-
STM1-S
-
-
-
16E1-S
-
-
-
CPU Reset (IDU) Available to reset CPU of IDU (Main/CTRL). Main ETH signal and NMS Communications will be downed after CPU Reset (IDU) is executed. L2SW Device Reset Reset should be executed for L2SW of IDU (MB/CTRL). Main signal will be downed during the executing. CPU Reset (ODU) Available to reset CPU(ODU) and control each ODU individually. Main signal will be downed during the resetting. After CPU Reset (ODU) finished, ODU need to be resetting the configuration information that retains by IDU (MB/CTRL). CPU Reset (ODU) replies NG response and not execute if MODEM did not mounted (include in not registered and mounted different place). Card Reset Available to control each option card individually. Main ETH signal will be downed during the resetting. After Card Reset finished, option card need to be resetting the configuration information that retains by IDU (MB/CTRL). Card Reset replies NG response and does not execute if option card was not registered, not mounted and mounted different place
NEC Confidential
MAINT Control- H/W Reset Control
Reset control available only when Maintenance Mode is On
NEC Confidential
F/W RESET CONTROL Reset control available only when Maintenance Mode is On
NEC Confidential
OFFLINE MAINT CONTROLParameter DADE
Operational system (RXSW selection) is fixed to run DADE. The operational system does not change to avoid any circuit interruption.
Offset
After DADE adjustment, it offsets in a DADE memory
DADE
so the amount of delay may serve as the minimum. Due to the memory offset, it may cause a circuit interruption.
DADE Off
DADE does not adjust, but in order to make the amount of delay into the minimum, it is set as the very end of the memory.
IN (1+1) CONFIGURATION, CH1 AND CH2 RX PATH DELAY AT THE INPUT OF THE SWITCH MAY NOT BE EQUAL. AUTOMATIC DADE ADJUSTMENT INSERT ADDITIONAL DELAY IN ONE CH TO MAKE THEM IN PHASE FOR THE HITLESS SWITCH TO OPERATE PROPERLY. SELECT DADE AND CLICK SET TO MEMORIZE THE DELAY SETTING ADJUSTED UNDER AUTO DADE. THIS DELAY IS ADJUSTED ONLY IN THE STANDBY PATH. SELECT OFFSET DADE AND CLICK SET TO REDUCE THE ABSOLUTE DELAY BETWEEN THE TWO RX CHANNELS. THIS ADJUSTMENT MAY INTERRUPT THE RADIO LINK. SELECT DADE OFF AND CLICK SET WHEN DADE ADJUSTMENT IS NOT REQUIRED.
NEC Confidential
NEO ODU CAN CHANGE THE FREQUENCY SUB BAND BY CHANGING THE TX/RX RF BPF. AFTER CHANGING THE SUBBAND FILTER NEW SUB BAND LETTER USED SHOULD BE SET IN THE ODU USING THIS OFFLINE CONTROL. IF YOU CHANGE THIS PARAMETER WITHOUT CHANGING THE SUB BAND FILTER RADIO LINK MAY FAIL. SELECT FROM THE DROP DOWN LIST THE SUB BAND LETTER TO BE USED AND CLICK THE SET BUTTON
METERING
NEC Confidential
Metering Default refresh rate is 10m sec. to have faster refresh rate click on the Modem or modem SW Group and select the High speed 3 sec radio button.: To stop High speed Refresh rate click the Cancel button
Select the Current Metering from the Metering menu. Current metering screen shows: TX Power in dBm RX Level in dBm ODU power Supply in volts BER TX Modulation (Current) RX Modulation (Current) Fan Speed of each Fan in rpm.
NEC Confidential
INVENTORY
NEC Confidential
INVENTORY – IDU (1000)
NEC Confidential
INVENTORY - IDU
NEC Confidential
INVENTORY - ODU
NEC Confidential
S/W License Information -1000
NEC Confidential
S/W License Setup
NEC Confidential
S/W LICENSE SETUP – IMPORT LICENSE KEY
NEC Confidential
S/W LICENSE SETUP-RADIO CAPACITY SETTING
NEC Confidential
S/W LICENSE SETUP-SFP Port License Setting
In iPASOLINK 1000 GbE Universal card can be used in Slot 9 and 10 only
NEC Confidential
Equipment Utility
NEC Confidential
Equipment Utility- Export (NE>Storage) Utility Use this function to export the Equipment Config Data, Network Config Data and User Config Data from NE to storage (Local PC or USB Memory)
Select Export (NE-> Storage) Utility from the Equipment Utility Menu. Select Export Item by clicking the appropriate Radio button: Equipment Config Network Config User Config Inventory Data Select the Local PC or USB Memory radio button in the Export to section. USB Memory radio button is active when the USB stick is mounted in the IDU MEM slot and is detected by it. Click the Execute icon, File Download window opens click Save button and select the destination in the Save As window. Click Save again to save the config file in the selected destination. Click the Close button in the Download Complete window.
NEC Confidential
UPDATE - Program Files Use this function to update NE by download Program File, FPGA Data and Config Data from storage (Local PC or USB Memory) to NE.
NEC Confidential
UPDATE - FPGA Files Use this function to update NE by download Program File, FPGA Data and Config Data from storage (Local PC or USB Memory) to NE.
NEC Confidential
Update – Configuration Files. Use this function to update NE by download Program File, FPGA Data and Config Data from storage (Local PC or USB Memory) to NE.
NEC Confidential
Equipment utility Program ROM Switching
NEC Confidential
SHIPMENT
The iPASOLINK can be reset to shipment setting to clear the current provisioning setting. Select the Shipment setting from the Equipment Utility menu.. The modules used are shown on the Equipment Utility- Shipment screen. Click the Shipment icon and select Provisioning clear from the drop down menu. Click OK.
Click OK on the warning indication. Click OK on the Information window “The server has terminated the session .Please Login again”. NEC Confidential
DATE / TIME SETTING & USB Memory Utility USB Memory utility allows to see the contents of the USB memory stick plugged in to the USB slot. It show the files inside the folder named Config.
NEC Confidential
LOG CLEAR FUNCTION
Select Log Clear Function from the Equipment Utility Menu.. Select the Radio button of the Log Type to be cleared, Alarm Log, Status Log, Command Log or All Logs and click the Execute button Click OK on the confirmation screen. When complete information window opens click OK.
NEC Confidential
User Account / Security Setting
NEC Confidential
LOGIN USER LIST LOGIN USER LIST menu shows a list of Users logged in to the NE, locally and remotely.
Click on the Group name of the logged in User to change the group setting
Click on the User name to modify the logged in user's password or user group.
Click on the Set Password In User Setting window to change the User Password
To change the User Group click on the Group field and select from the drop down list the group to be changed to.
NEC Confidential
Click on the Access Level field and from the drop down list select the new access level for the Group
USER ACCOUNT MANAGEMENT
User Account Management function allows adding , Modifying and deleting of User accounts. This function is available for Admin Access level users only Up to nine user accounts can be added in addition to the three default user accounts (User, Config & Admin). Click on the ADD USER icon on the Use Account / Security Setting window. Enter the User Name and select the Group from the drop down list of registered user groups. Click on the Set Password icon on the User Setting window to open the Set Password window. Enter the password for the new user and re-enter it to confirm the password and click OK Click on the OK button to register the new user.
NEC Confidential
USER ACCOUNT / SECURITY SETTING MD5 ( Message Digest 5 ) one of the Hash Algorithm for authentication and digital signature. In order to detect the falsification of original data during the data transmission. Original data will be converting the Hash by comparing at both ends SHA (Secure Hash Algorithm ) one of the Hash Algorithm for authentication and digital signature. In order to detect the falsification of original data during the data transmission. Less than 264 bits of original data will be converting the Hash of 160 nits by comparing at both ends DES (Data Encryption Standard ) is 56 nit encryption key and encryption by 64 bit block
AES (Advanced Encryption Standard ) SPN structured block encryption, block length is 128 bits and the length of key 128/192/256 bits
Item
Parameter
User Name
1 t0 31 Characters
Password
8 to 31 Characters
Group
Default Groups ADMIN/CONFIG/OPERATOR or Added Groups
Security Level : NoAuthNoPriv
User Login Without authentication and encryption
Security Level : AuthNoPriv
User Login need authentication (MD5 or SHA1 based) but without (Privacy) encryption
Security Level : AuthPriv
User Login need Authentication (MD5 or SHA1 ) and the data is encrypted by DES or AES
Auth Algorithm
Select Authentication Algorithm between MD5 or SHA
Auth Key
Input 8 to 16 digit Public key of MD5 and SHA1
Priv Algorithm
Select the encryption method DES or AES
Priv Key
Input 8 to 16 digits Key of DES or AES
NEC Confidential
USER ACCOUNT MANAGEMENT
MODIF Y USER
SET PASSWO RD
NEC Confidential
DELETE USER
USER GROUP PROFILE CONFIGURATION In addition to the three default groups (OPERATOR/ CONFIG/ ADMIN) Six additional groups can be registered.
PARAMETER
NEC Confidential
DESCRIPTION
Group Name
1 to 32 characters
FTP
Allow or Deny using FTP protocol
HTTP
Allow or deny using HTTP protocol for WebLCT to access Equipment
SNMP
Allow or deny using SNMP protocol to access network equipment
Access Level
Specify the User Access Level
SECURITY MANAGEMENT
Protocol or Service Enabled Protocol or Service Disabled
NEC Confidential
SNMP and SNMP Community SETTING
Default UDP Port is 161 Up to 10 SNMP Managers can be registered to access the iPasolink NEs.
Item
Parameter
Description
Community Name
1 to 31 Characters
Set the SNMP community name. Any request with different community name will be refused
Access Level
CONFIG- allows only GET ADMIN – Allows GET and SET
Assign the access level to the specified server(s)
Access address
xxx.xxx.xxx.xxx
Specify the valid IP address or network of the SNMP Manager(s)
Subnet Mask
255.xxx.xxx.xxx
Subnet Mask of SNMP Manager(s)
NEC Confidential
SNMP Trap Entry SETTING
Item
Parameter
Description
SNMP Version
V1 / v2c / v3
Set SNMP version for trap
PDU Type
Trap / Inform
Set PDU Type for Trap Inform PDU is for SNMPv2 and SNMPv3
IP Address
0.0.0.0
Specify the destination IP address of trap
Port
162 (default) (1 t0 65535)
Set UDP Port trap
Community name
1-31 Character
Set communication name of the trap. This much match on both SNMP server and agent
Security Level
NoAuthNoPriv/ AuthNoPriv/AuthPriv
SNMP Engine ID
10-64 numeric Characters
Auth Algorithm
MD5 or SHA
Auth Key
8 to 16
Priv Algorithm
DSE or AES
Priv Key
8 to 16
NEC Confidential
SNMPv3 local engine ID
Enter the Public key for MD5 or SHA
Enter the Key for DES or AES
USER ACCOUNT / SECURITY SETTING
NEC Confidential
FTP and SFTP setting
Item
Secure File Transfer Protocol, SFTP is similar to FTP, which performs all file transfer operations over an encrypted SSH transport. operations
Parameter
Description
FTP
Enable (Running) Disable (Stopped) Always Enable
Start and Stop FTP service
TCP Port (Command)
21(default)
Set TCP port of FTP server (for received command) ) (1 to 65535)
TCP Port (Data)
20 (Default)
Set the TCP port of FTP server (for data transmit) (1 to 65535)
Max session
3
Maximum user connection
Auto Stop
Enable
Enable FTP server break the connection in 90 sec automatically after no operation on the client
Disable
Disable FTP server break automatically
NEC Confidential
HTTP and HTTPS setting
Item
Parameter
Description
HTTP
Enable (Running) Disable (Stopped)
Start and Stop HTTP service
TCP Port
80(default)
Set the port number of HTTP server (1 to 65535)
Item
Parameter
Description
FTP
Enable (Running) Disable (Stopped)
Start and Stop FTP service
TCP Port (Command)
21(default
Set TCP port of FTP server (for received command) ) (1 to 65535)
TCP Port (Data)
20 (Default)
Set the TCP port of FTP server (for data transmit) (1 to 65535)
Max session
3
Maximum user connection
Auto Stop
Enable
Enable FTP server break the connection in 90 sec automatically after no operation on the client
Disable
Disable FTP server break automatically
NEC Confidential
Current/History PMON/RMON Report
NEC Confidential
MODEM PMON REPORT
NEC Confidential
MODEM PMON REPORT
NEC Confidential
E1PMON REPORT
Monitor the E1 code violation of each E1 channel
NEC Confidential
ESTM-1 PMON REPORT
NEC Confidential
ETH RMON REPORT
NEC Confidential
ETH RMON REPORT
NEC Confidential
VLAN COUNTER REPORT
NEC Confidential
iPASOLINK Alarms
F/W Ver 1.01.11 NEC Confidential
XPIC CONFIGURATION SETTING
NEC Confidential
XPIC Configuration (1 + 0 ) F1 (V) F1 (H)
Vertical Horizo ntal
(1+0) XPIC
F1 (V)
F1 (H)
Vertical
Vertical
Horizo ntal
Horizo ntal
NEC Confidential
F1 (V) F1 (H)
XPIC configuration ( 1 + 1 ) F1 (V)
F1 (H)
F1 (V)F2(V)
F1 (H)F2 (H)
Vertical F1 Vertical F1 Horizon Horizon tal F1 tal F1
Hot standby
Vertical F2 Vertical F1 Horizon Horizon tal (F2) tal (F1)
Twin Path
NEC Confidential
XPIC Configuration – (1+1) two IDU Master-2 (V ) Master-1 (V )
F1 ( V ) Vertical
F2 ( V ) Horizontal
Slaver-1 (H ) Slaver-2 (H )
Two IDU ( 1 + 1 ) XPIC –(Hot Standby)
NEC Confidential
XPIC-EQUIPMENT CONFIGURATION (1of 9) 1
1 2
Select Equipment Configuration from the Equipment Setup menu. Equipment Configuration screen shows the Current configuration. Current example shows the shipment setting. (not configured) Green border on the universal slot positions indicate detection of modules in these slots. Click on the Setup Icon to open setup wizard. The first setup screen is the setup 1 Setting of Equipment Name window.
3
Enter the Equipment name. (up to 32 character).
4
Click the Next button to open the Step2 Setting of Equipment slot
Left hand side shows the current setting of mounted modules and the redundancy configuration for radio and STM-1.
3
4
NEC Confidential
Right hand side is used for New settings available in Steps 1 to 4
XPIC-EQUIPMENT CONFIGURATION (2 of 9) Step-2 Setting of Equipment Slot : selects the Universal Slots configuration.
3 2
5
1
1
Click on the drop down arrow of each slot position and select the module inserted in the slot from the list. If the inserted module are not known click the Auto Detect button to select automatically.
2
If the optional clock module is not used deselect the check box. (default is selected) Select the Clock Option
3
Select the second Power supply module if used
4
Click the Next button to open the Step3 Setting of Modem/STM SW/ XPIC GRP Configuration
2 3
Slot 01 / 02
Slot 03 / 04 NEC Confidential
XPIC-EQUIPMENT CONFIGURATION (3 of 9) This window select the radio redundancy, XPIC group setting and STM-1 APS setting. Slots 1/ 2 is one radio and XPIC group. Slots 3 /4 is the second group. Depending on the number of modems mounted Check boxes are active. Click on the check box and select (1+1) HS or (1+1) TP or XPIC configurations
1
1
2
When slots 01/02 have modems assigned, first switch group is active. When all four modems are assigned then both switch groups can be configured for hot standby or twin path or XPIC
Select the required configuration from the drop down list 2
Examples of different XPIC Configuration
NEC Confidential
Click the Next button to open the Step4 Setting Confirmation Screen
XPIC-EQUIPMENT CONFIGURATION (4 of 9) The configuration changes are sown in blue back ground. Confirm the changes are correct and click the OK button
1
2 2
Click OK on the warning window
3
Click OK on the Complete information window
1
3
Examples of different XPIC Configuration Confirmation Screens
NEC Confidential
EQUIPMENT CONFIGURATION (5 of 9) Radio Configuration screen display the (1+1) XPIC configurations. Slot 01 and Slot 02 are Master1 and Master2
Radio Configuration screen display the XPIC GRP1 and XPIC GRP2 (1+0) configurations.
SLOT03 and SLotg04 are Slave1 and Slave2
NEC Confidential
XPIC – Provisioning setting (6 of 9)
2
1
This parameter defines what should happen in ODU when the reference oscillator fails. Select Mute radio button to cut the RF output. Select REF LO-> Self LO radio button to use the ODU Self Local Oscillator. 1
Select XPIC Setting from the Provisioning Modem Function Setting Menu. Current XPIC setting for XPIC Condition – Local Fail is shown in the XPIC Setting Screen.
2
Click the XPIC GRP# (Modem) (Slot #/ Slot# ) under lined text to open the XPIC Condition – Local Fail control window
3
Select Mute or REF LO -> Self LO radio button
4
Click the OK button to apply the setting
3
4
NEC Confidential
XPIC- Provisioning - TX Power ( 7 of 9) 1
2 2
Select TX Power setting from the Provisioning Modem Function Setting menu Select XPIC GRP# (Modem) (slot#/Slot#) on the TX Power Setting window
1
2
1 2
3
(1+1) XPIC GRP 2
(1+0) XPIC GRP
3
TX Power setting is set for the Master modem, Slave modem is automatically adjusted for the same setting. Enter the TX Power and RX Threshold values and click the OK button
NEC Confidential
XPIC- Maintenance Control (8 of 9) This Maintenance Control manually Reset the XPIC function. Default (normal) setting is Auto. 1
1
Select Modem Maintenance Control from the Maintenance Control Menu. 2
Modem Maintenance Control screen shows the status of the XPIC specific Control 2
2
Click on the under lined Text Auto in the XPIC Rest control to open the XPIC rest control window. Select Forced Reset radio button to Reset XPIC function Select Auto radio button normal XPIC function
3
Click the OK button to apply the control
2
3
NEC Confidential
XPIC –X-DEM Delay Adjust (9 of 9) X-DEM DELAY ADJUST FUNCTION IS USED TO ADJUST FOR THE ODU-IDU CABLE LENGTH DIFFERENCE BETWEEN THE MASTER CABLE AND THE SLAVE CABLE. WHEN CABLE LENGTH DIFFERENCE BETWEEN XPIC MASTER AND SLAVE IS LARGER THAN 8 METERS, THIS ADJUSTMENT IS REQUIRED IN THE XPIC MASTER SIDE.
1 1
Select Offline Maintenance Control from the Maintenance Control Menu
2
Default value for X-DEM Delay Adjust is -8 to + 8 (m)
2
Click on the underlined text to open the X-DEM Delay adjust control window. 3
Click on the drop down list and select the X-DEM Delay Adjust value base don the difference between the Master cable and the Slave cable relative to Master cable. (see the example given below)
4
Click the OK button to apply the setting
4
EXAMPLE: MASTER 30M, SLAVE:16M, DIFFERENCE = +14M SET THE MASTER SIDE X-DEM TO +8 TO +16 MASTER: 16M, SLAVE: 30M, DIFFERENCE = -14 SET THE MATER X-DEM TO -16 TO -8
3
4
NEC Confidential
RADIO AGGREGATION SETTING
Modem Slot1
Modem Slot2
Modem slot3
Modem slot4
Not used
Not used
Group1 Group1
Not used Group1
Group1
NEC Confidential
Group2
Radio Aggregation – Radio Setting (1 of 5) 2
1
1
Select Radio Configuration from the Equipment Setup Menu to display the Radio Configuration screen
2
Click the Setup icon on the Radio Configuration screen to open the Step-1 of the radio configuration wizard.
3
Select radio parameters: (for Modem (slot01))
4
Select Radio Group1 from the Radio Traffic aggregation drop down list
5
Click the Next Button to configure the Modem (slot02)
3
Channel Spacing Reference Modulation Radio Mode TDM Setting TX Frequency Frame iD TX Power Control Mode 4
5
NEC Confidential
Radio Aggregation – Radio Setting- (2 of 5) 1
2
3
2
1
Configure the radio parameters on Modem Slot02. Radio aggregation is already selected as Radio GRP1 (As there is only two modems configured in this example)
2
Click the NEXT button to got step2 setting confirmation screen
3
Confirm the setting and click the OK button to go back to Radio Configuration screen
3
NEC Confidential
Radio aggregation - VLAN setting (3 of 5) 1
Select VLAN setting from the Provisioning ETH Function Setting Menu
2
Select the LAG Radio group1 and assign the VLANs to the aggregation group as well as the ETH Ports to be used.
3
Click the OK button to go back to VLAN Setting screen.
4
Confirm that the VLANs are assigned to the Radio Aggregation Group and the ETH port(s)
1
2
4 2
3
NEC Confidential
Radio Aggregation – LAG Setting (4 0f 5) 2 1
1
Select Link Aggregation Setting from the Provisioning ETH Function Setting Menu Link Aggregation Setting screen shows the Radio GRP1 in the Link aggregation Group section. Default Distribution rule is L2 Base
2
3 2
To assign a name to the LAG (optional) or change the distribution rule, click the Modify Link Aggregation icon.
3
Enter the Link aggregation Group name in the LAG Name field. (32 Characters). Click the Distribution Rule drop down list and select L2 Base or L3 Base as the distribution rule. L2 Base uses the MAC address as the distribution criteria, L3 Base uses the IP address as the distribution criteria
4
Click the OK button to apply the changes 4
NEC Confidential
Radio Aggregation – Alarm/Status (5 of 5)
1
Radio Aggregation status is shown in Current Status under the Modem/ODU and IDU tabs.
2
1
When the Links in the aggregation loop are normal Radio Traffic aggregation Port Status indicate as Active, It shows as Standby the links that are down.
2
When at least one link in the Radio aggregation group is normal Radio Traffic Aggregation Link status is shown as Normal. If all the links in the radio aggregation Group are down then the Radio Traffic Aggregation Link Status is shown as Alarm
NEC Confidential