Itron Modbus Table V502
Home
Itron Modbus Table V502
Itron Modbus Table V502...
Author:
ben
22 downloads
596 Views
692KB Size
Report
DOWNLOAD .PDF
Recommend Documents
Itron Modbus Table V502
Itron Modbus Table V502Full description
Itron Modbus Table V502
Itron Modbus Table V502Full description
Modbus
Modbus
Itron MbusRead
Full description
modbus
Sony Dxa-V502 Sm
SONYDescripción completa
Sony Dxa-V502 Sm
SONYDescripción completa
Modbus Java
Descripción completa
02 - Modbus
Modbus
Módulo Modbus
Descripción: comunicaciones industriales
Protocolo Modbus
Datos comunicación Modbus
Modbus Rtu
modbus protocol.doc
Full description
Itron ACE8000.pdf
Full description
iTron - Petunjuk Penggunaan Listrik Prabayar
Life Table (Table Mortalitas)
Ethernet Modbus TCPIP
Modbus Manual Alfa 3104C
Descrição completa
Modbus Tester Help
iTron - Petunjuk Penggunaan Listrik Prabayar
Full description
Presentacion de Modbus
Documento en castellano para entender Modbus
Protocolo Comunicacion Modbus-ethernet
Como comunicarse con protocolos Modbus utilizando PLC M340Descripción completa
komunikasi MODBUS PM5300
komunikasi modbus PM5300
VLT 2800 modbus RTU
Modbus table
N 1
Variable
Description
Address
Access
Production
2
XPCD
Manufactur ing date
254
Active
3
XPCS
Converter Ser ial number
258
Active
4
XP CFV
F irmware version
0
Active
5
XP CFD
F irmware date
498
Active
6
Thresholds
7
XICP
Pulse inputs coherence inter val period
6
Active
8
XICH
Pulse inputs coherence high threshold
7
Active
9
XICM
Pulse inputs coherence contr ol activation flag
8
Active
10
MVBI_CT
Base consumption high threshold
10
Active
11
MVBI_CP
Base consumption measure period
12
Active
12
M FRTF
Unconverted flowrate alarms activation flag
13
Active
13
MFBTF
Converted flowrate alarms activation fl ag
14
Active
14
MFRTL
Unconverted flowrate low threshold
16
Active
15
M FRTH
Unconverted flowrate high thr eshold
18
Active
16
MFBTL
Converted flowrate low threshold
20
Active
17
M FBTH
Converted flowrate high thr eshol d
22
Active
18
Conversion Conversio n parameters
19
M CP
Conversion period
26
Active
20
M CF
Conversion formula
27
Active
21
M ZDR
Gas relative densi ty (specific gravity)
32
Active
22
M CRP
Base pr essure
34
Active
23
MZP
Gas superior heating value
36
Active
24
MZAP
AGA8 r efer ence pressure(Pr d)
38
Active
25
MZAT
AGA8 r efer ence tem perature(Trd)
40
Active
26
MPF
Gas fixed relative pr essure
42
Active
27
MPA
Converter's altitude
24
Active
28
M CRT
Base temperature
44
Active
29
MZC
16 coefficients formula
46
Active
30
M ZCO2
Gas %CO2
78
Active
31
MZH2
Gas %H2
80
Active
32
MZN2
Gas %N2
82
Active
33
MZF
F ixed gas compressi bility ratio (T or PT conv
84
Active
34
M CAF0
Methane % for AGA8
1140
Active
35
M CAF1
Nitr ogen % for A GA8
1142
Active
36
M CAF2
CO2 % for A GA8
1144
Active
37
M CAF3
Ethane % for A GA8
1146
Active
Modbus table
N
Variable
38
MCAF4
39
Address
Access
Propane % for AGA8
1148
Active
MCAF5
H2O % for AGA8
1150
Active
40
MCAF6
Hydrogen sulfid % for AGA8
1152
Active
41
MCAF7
H2 % for AGA8
1154
Active
42
MCAF8
CO % for AGA8
1156
Active
43
MCAF9
O2 % for AGA8
1158
Active
44
MCAF10
i-Butane % for AGA8
1160
Active
45
MCAF11
n-Butane % for AGA8
1162
Active
46
MCAF12
i-Pentane % for AGA8
1164
Active
47
MCAF13
n-Pentane % for AGA8
1166
Active
48
MCAF14
n-Hexane % for AGA8
1168
Active
49
MCAF15
n-Heptane % for AGA8
1170
Active
50
MCAF16
n-Octane % for AGA8
1172
Active
51
MCAF17
n-Nonane % for AGA8
1174
Active
52
MCAF18
n-Decane % for AGA8
1176
Active
53
MCAF19
Helium % for AGA8
1178
Active
54
MCAF20
Argon % for AGA8
1180
Active
55
Description
Pressure
56
MPTL
Pressure low threshold
86
Active
57
MPTH
Pressure high threshold
88
Active
58
MPSC16
Pressure sensor model coefficients
90
Active
59
MPB
Pressure backup value
140
Active
60
MPSS
Pressure sensor serial number
142
Active
61
MPLG
Linearisation coefficient D
148
Active
62
MPLO
Linearisation coefficient C
150
Active
63
Temperature
64
MTSS
Temperature sensor serial number
154
Active
65
MTTL
Temperature low threshold
160
Active
66
MTTH
Temperature high threshold
162
Active
67
MTB
Temperature backup values
164
Active
68
MTLG
Linearisation coefficient B
188
Active
69
MTLO
Linearisation coefficient A
190
Active
70
MCTF
Conversion factor alarms activation flag
192
Active
71
MCTL
Conversion factor low threshold
194
Active
72
MCTH
Conversion factor high threshold
196
Active
73
MXBE
Backup values enable flag
198
Active
74
MXBA
Backup values auto-update flag
199
Active
Modbus table
N
Variable
75
MXL
76
Description
Address
Access
Linearisation function activation
200
Active
On/off output #1 mode
218
Active
Outputs
77
XOM1
78
XOVC1
Volume output #1 time closed
219
Active
79
XOVW1
Volume output #1 pulse weight
220
Active
80
XOAM1
On/off output #1 alarm mask
222
Active
81
XOAC1
Alarm output #1 time closed
224
Active
82
XODD1
4-20mA output #1 tracked data
225
Active
83
XODL1
4-20mA output #1 tracked data level @4mA
226
Active
84
XODH1
4-20mA output #1 tracked data level @20mA
228
Active
85
XOM2
On/off output #2 mode
234
Active
86
XOVC2
Volume output #2 time closed
235
Active
87
XOVW2
Volume output #2 pulse weight
236
Active
88
XOAM2
On/off output #2 alarm mask
238
Active
89
XOAC2
Alarm output #2 time closed
240
Active
90
XODD2
4-20mA output #2 tracked data
241
Active
91
XODL2
4-20mA output #2 tracked data level @4mA
242
Active
92
XODH2
4-20mA output #2 tracked data level @20mA
244
Active
93
XOPC0
Period completion signal duration #1
1127
Active
94
XOPC1
Period completion signal duration #2
1128
Active
95
XOPM0
Period completion signal period #1
1129
Active
96
XOPM1
Period completion signal period #2
1130
Active
97
Client
98
XPCI
Converter commissioning date
256
Active
99
XPMS
Associated meter serial number
268
Active
100
XPC1
Label data#1
278
Active
101
XPC2
Label data#2
304
Active
102
XPC3
Label data#3
330
Active
103
ALPHANUM
Alphanum string
346
Active
104
Inputs
105
XIM
On/Off Input configuration mode
535
Active
106
XDZ
Compressibility ratio (display of Z/Zo or Zo/Z)
536
Active
107
XIS
Switch status
560
Active
108
Unit
109
XUP
Pressure Unit
537
Active
110
XUT
Temperature Unit
538
Active
111
XUV
Volume Unit
539
Active
Modbus table
N
Variable
112
XUN
113
XUE
114
Description
Address
Access
Standard or Normal unit for converted data
540
Active
Energy unit (used only for PCS in GERG for
541
Active
Various
115
XD0
Flag display remaining '0' at the left of index
542
Active
116
XSM
Flag configuration battery / External
544
Active
117
Power supply
118
XSBR
Battery autonomy counter
548
Active
119
XSBN
Battery capacity (days)
549
Active
120
Date/Time
121
XDC
Current date and time
546
Active
122
XNSC
Next daylight saving switch date S to W
550
Active
123
XNWC
Next daylight saving switch date W to S
552
Active
124
XTSM
Winter/summer time management mode
554
Active
125
XTSS
Summer time switching date/time
556
Active
126
XTSW
Winter time switching date/time
558
Active
127
Alarms Reset
128
ARS
Non metrol. alarm reset
561
Active
129
ARM
Metrol. alarm reset
562
Active
130
APL
P low threshold alarm
564
Active
131
APH
P high threshold alarm
576
Active
132
APF
P sensor failure alarm
588
Active
133
ATL
T low threshold alarm
600
Active
134
ATH
T high threshold alarm
612
Active
135
ATF
T sensor failure alarm
624
Active
136
AIC
LF coherence alarm
636
Active
137
AIT
Tampering alarm
648
Active
138
AIO1
On/off input1 alarm
660
Active
139
AIO2
On/off input2 alarm
672
Active
140
AFRL
Low Unconverted flow rate alarm
684
Active
141
AFRH
High Unconverted flow rate alarm
696
Active
142
AFBL
Low Converted flow rate alarm
708
Active
143
AFBH
High Converted flow rate alarm
720
Active
144
ACL
C factor Low threshold alarm
732
Active
145
ACH
C factor High threshold alarm
744
Active
146
ASB
Battery Low alarm
756
Active
147
ASE
External power supply failure alarm
768
Active
148
AVC
Consumption high threshold alarm
780
Active
Modbus table
N
Variable
149
AXA
150
AXM
151
Database Configuration
152
Address
Access
Bitfield active alarms
792
Active
Bitfield mmemorized alarms
794
Active
DIL
Database interval length
796
Active
153
DIM
Interval log : Optional congiguration part
797
Active
154
DGH
Gas hour
798
Active
155
DGD
Gas day
799
Active
156
DM
Database activation
800
Active
157
DRC
Calendar database reset
802
Active
158
DRI
Interval database reset
803
Active
159
Description
Volumes
160
MVW1
Input pulse weight
4
Active
161
MVRI
Unconverted index
806
Active
162
MVBI
Converted index
810
Active
163
MVRC
Unconverted counter under alarm
814
Active
164
MVBC
Converted counter
818
Active
165
MFRG
Instantaneous Unconverted Flow rate
822
Active
166
MFBG
Instantaneous Converted Flow rate
824
Active
167
MTG
Instantaneous T
834
Active
168
MPG
Instantaneous P
836
Active
169
MCM
Instantaneous C
838
Active
170
MZZ
Instantaneous Z
840
Active
171
MZR
Instantaneous Z ration
842
Active
172
Communication
173
XSC
Slot extension mode
847
Active
174
XCM
RS232 external modem type
848
Active
175
XCAT0
RS232 external modem command AT0
850
Active
176
XCAT1
RS232 external modem command AT1
870
Active
177
XCAT2
RS232 external modem command AT2
890
Active
178
XCAT3
RS232 external modem command AT3
910
Active
179
XCATR
RS232 external modem AT answer
930
Active
180
XCATH
RS232 external modem init hour
934
Active
181
XCS
RS232 external modem speed
935
Active
182
Remote alarm
183
XRAM
Bit Field Alarm
1070
Active
184
XRAP
Modem type
1072
Active
185
XRAA
Call repetition policy
1073
Active
Modbus table
N
Variable
186
XRAR
187
Description
Address
Access
Nb call
1074
Active
XRAT
Tempo
1075
Active
188
XRAH
Hourly repetition
1076
Active
189
XRAN0
Phone 1
1078
Active
190
XRAN1
Phone 2
1090
Active
191
XRAN2
Phone 3
1102
Active
192
XRAF
Function Activation
1113
Active
193
XRAS
Status table
3848
Active
194
dbus Communication setti
195
XCMPF1
RS232 Activation
1186
Active
196
XCMPA1
RS232 Address
1187
Active
197
XCMPT1
RS232 time out
1188
Active
198
XCMPS1
RS232 Speed
1189
Active
199
XCMPF2
Optional channel Activation
1190
Active
200
XCMPA2
Optional channel Address
1191
Active
201
XCMPT2
Optional channel time out
1192
Active
202
XCMPS2
Optional channel Speed
1193
Active
203
XCMFT
Float Type Reverse
2006
Active
204
XCST1
Answering time out IFLAG RS232
2009
Active
205
XCST2
Answering time out IFLAG RS485 port1
2010
Active
206
XCST3
Answering time out IFLAG RS485 port2
2011
Active
207
XCMT1
Answering time out MODBUS RS232
2013
Active
208
XCMT2
Answering time out MODBUS RS485 port1
2014
Active
209
XCMT3
Answering time out MODBUS RS485 port2
2015
Active
210
New parameters V0.75
211
MP2LG
Linearisation coefficient D'
2064
Active
212
MP2LO
Linearisation coefficient C'
2066
Active
213
MP2SS
P2 sensor serial number
2068
Active
214
MP2CTF
Activation Flag for P2 warnings
2074
Active
215
MP2TL
P2 pressure low threshold
2076
Active
216
MP2TH
P2 pressure high threshold
2078
Active
217
MP2SC16
P2 pressure sensor model coefficients
2080
Active
218
MP2G
P2 instantaneous pressure
2116
Active
219
MPCTF
Activation Flag for pressure warnings
2118
Active
220
MPCTL
Pressure warning low thershold
2120
Active
221
MPCTH
Pressure warning high thershold
2122
Active
222
MTCTF
Activation Flag for temperature warnings
2124
Active
Modbus table
N
Variable
223
MTCTL
224
MTCTH
225
Description
Address
Access
Temperature warning low thershold
2126
Active
Temperature warning high thershold
2128
Active
AP2L
P2 low warning
2132
Active
226
AP2H
P2 high warning
2144
Active
227
AP2F
P2 failure alarm
2156
Active
228
ATCL
T low warning
2192
Active
229
ATCH
T high warning
2204
Active
230
APCL
P low warning
2168
Active
231
APCH
P high warning
2180
Active
232
MZPA
Atmospheric pressure
2216
Active
×
Report "Itron Modbus Table V502"
Your name
Email
Reason
-Select Reason-
Pornographic
Defamatory
Illegal/Unlawful
Spam
Other Terms Of Service Violation
File a copyright complaint
Description
×
Sign In
Email
Password
Remember me
Forgot password?
Sign In
Our partners will collect data and use cookies for ad personalization and measurement.
Learn how we and our ad partner Google, collect and use data
.
Agree & close