This document is very helpful for BSS description.
Alarm alaysisDescrição completa
Alarms Analysis
Description for alarms cables used in ZTE.
Full description
Full description
Monitorable alarms for NOC BSS
Version:
Compiled by Muhamamd Zubair Hayder NOC Engineer 0345 8504117
Page 1
1.2
1. EXTERNAL/ENVIRONMENTAL ALARMS The following External/Environmental Alarms need to be monitored and escalated to respective teams by NOC. Number
Nokia Power System (#1) Alarms OUTDOOR/INDOOR
Nokia Power System Indoor BTS
Nokia Power System(#2) Indoor BSC
Metrosite MicroBBu Power System
4000
BSS Alarm on BSC 4001
Q1 Alarm
Alarm No
Alarm Type
7401
Urgent
7402
Warning
7403
Message
7404
Low System
7405
Distribution
7406
Battery Failure
7407
Generator running.
7408
Obstruction lights failure *
7409
Low Fuel
7410
Door - access.
7411
High temperature.
7412
Aircondition failure.
7413
Fire/smoke.
7414
AVR faillure
7417
BTS Power One Urgent
7418
BTC Power One Service
7419
BTC Power One Mains AC failure
7420
BTC Power One Battery
7421
BSC Power One Urgent
7422
BSC Power One Service
7423
BSC Power One Mains AC failure
7424
BSC Power One Battery
7401
Low Voltage Cab1
7402
Module Fail Alarm
7403
High Temp over 40 C cab1
7404
Low Temp below -5 C cab1
7405
Mains failure cab1
7406
Low Voltage Cab2
7407
High Temp over 40 C cab2
7408
Low Temp below -5 C cab2
7409
Mains failure cab2
1-PWR1
URGENT
2-PWR2
SERVICE
3-PWR3
MAINS Failure
4-PWR-4
BATTERY
EX
DOOR ACCESS
EX
HIGH TEMP
EX
AC FAILURE
EX
FIRE/SMOKE
EX
INTRUDER
EX
AVR FAILURE
4777
EX
TELENOR TEST ALARM
8240
Salteq Eq Fail
ACTIVE ALARM POINT
Compiled by Muhamamd Zubair Hayder NOC Engineer 0345 8504117
Page 2
Temp Alarm Saltec AC Fail High Tem High V AC Fail Low V 8000
Repeater
Repeater
POWER SUPPLY FAULT
* - if applicable
2. LIST OF BTS ALARMS The following BTS/BCF alarms need to be monitored real time by NOC and need to be escalated to concerned teams (Field+BO). Service Affecting Alarms (related to BTS/BCF) Alarm No.
Description
7701
BCF Initialization
7704
PCM Failure
7706
BTS O&M Link Failure
7767
BCCH Missing
Quality Alarms Alarm No.
Description
7601
BCF Operation Degraded
7604
BTS Operation Degraded
7606
TRX Faulty
7607
TRX Operation Degraded
7738
BTS with no Transactions
3. TRANSMISSION ALARMS The following Transmission alarms need to be monitored real time by NOC and need to be escalated to concerned teams (Field+BO). Transmission Alarms 2925
SLIP FREQUENCY LIMIT EXCEEDED
8099
RECEIVED BIT ERROR RATIO (BER) > 1E-3
2923
CRC BIT ERROR RATIO OVER LIMIT
4. LIST OF BSC ALARMS The following BSC alarms need to be monitored real time by NOC and need to be escalated to concerned teams (BSC+BO). BSC Alarms Alarm No.
Description
2072
Failure in Signaling link Activation or Restoration
2250
Failure in D-Channel Activation or Restoration
2347
Power Supply Failure in CPU
2471
Radio Network Recovery Failed
2477
Global Reset Message Received
Compiled by Muhamamd Zubair Hayder NOC Engineer 0345 8504117
Page 3
2478
Mobile Access Classes Abnormal
2632
Oscillator Failure
2692
Incorrect Working State
2756
Cartridge Power Supply failure
2757
Cartridge Non-Redundant Power Supply Failure
2758
Power Supply Adapter Failure
2759
Power supply Fuse Failure
2760
HWAT Failure
2764
CLS Failure
2801
O&M Network System Unreachable
2860
Disk Failure
2948
Radio Network Intialization
2992
BTS & TC Unsynchronized Clear Calls on A Interface
2993
BTS & TC Unsynchronized Clear Calls on Abis Interface
3019
Network Service Entity Unavailable
9108
Failure in OMC-NE Communication link