Small write up about cathodic protectionFull description
Small write up about cathodic protectionFull description
Cathodic protection for storage TanksFull description
Full description
condenser Cathodic Protection
Description complète
Hgyd
Deepwater offkhore structures am now quite corumom however a deep water development project still &uims significant capital investment on the part of the operator. Corrosion failure is not …Full description
Full description
Cathodic Protection Design
Cathodic Protection ReportFull description
Full description
Cathodic ProtectionFull description
Cathodic ProtectionFull description
cathodic protection spec
PT. KARTINI UTAMA Corrosion and Production Flow Enhancement Control Systems Company
Established in 1968. Incorporated in 1972. 9 branches through-out. 1. Jakarta
PT. KARTINI UTAMA Corrosion and Production Flow Enhancement Control Systems Company
PRODUCT & SERVICES
DIV.1-CORROSION CONTROL SYSTEM: • CATHODIC PROTECTION SYSTEM • IMPRESSED CURRENT CATHODIC PROTECTION • SACRIFICIAL ANODE • MAGNESIUM • ALUMINUM • ZINC • CORROSION MONITORING SYSTEM • PROTECTIVE COATING SYSTEM • FIELD JOINT COATING (RAYCHEM Heat Shrink Sleeve) • LIQUID EPOXY COATING (POWERCRETE)
DIV.2-PRODUCTION FLOW CONTROL SYSTEM
2
PT. KARTINI UTAMA Corrosion and Production Flow Enhancement Control Systems Company
PRODUCT & SERVICES
SERVICES: ¾ ¾ ¾ ¾ ¾ ¾ ¾ ¾ ¾ ¾ ¾
CONSULTANCY DESIGN ENGINEERING SUPERVISIONING COMMISSIONING FIELD SURVEYS - ON & OFF SHORES CONSTRUCTIONS AND INSTALLATIONS FABRICATIONS AND ASSEMBLIES PROJECTS MANAGEMENT TURNKEY/EPC CONTRACTUAL UNDERTAKINGS MAINTENANCE ETC.,. 3
CLIENTS
PT. KARTINI UTAMA Corrosion and Production Flow Enhancement Control Systems Company
CALTEX PACIFIC INDONESIA BP AMOCO INDONESIA CONOCO INDONESIA UNOCAL INDONESIA TOTAL E&P INDONESIA VICO INDONESIA TRIPATRA ENGINEERING NIPPON STEEL NISCONI INDONESIA SHELL SEMPEC INDONESIA TECHNIP INDONESIA JR McDERMOTT INDONESIA CNOOC
• • • • • • • • • • • • • •
PUPUK SRIWIDJAJA PERTAMINA SEMEN TONASA PUPUK KALTIM PUPUK KUJANG PLN PDAM JASA MARGA CITRA INDONESIA KRAKATAU STEEL KOMARITIM BONTANG LNG MOBIL OIL INDONESIA KODECO INDONESIA
4
PT. KARTINI UTAMA Corrosion and Production Flow Enhancement Control Systems Company
ICCP vs Sacrificial Anode ICCP SYSTEM: •ADOBTABLE TO CONNECT WITH FOREIGN PIPELINE • MORE REASONABLE PRICE FOR LONG/BIG PIPELINE SYSTEM • EFFICIENT FOR HIGH SOIL RESISTIVITY • EXISTING SOURCE OF ELECTRIC POWER
TR
SACRIFICIAL ANODE:
ICCP:
LIMITATION OF CURRENT SUPPLY BY QUANTITY OF ANODE
CURRENT SUPPLY DRIVEN BY TRANSFORMER RECTIFIER
SACRIFICIAL ANODE: • “WITHOUT” MAINTENANCE
5
PT. KARTINI UTAMA Corrosion and Production Flow Enhancement Control Systems Company
CORROSION BASICS sacrificial anode cp systems
Pipe
Connection to pipe (return path of current)
CP current to pipe coating defect
Coating defect
Failed coating-exposed steel
Sacrificial Anode (e.g. Aluminium, Magnesium or Zinc)
6
PT. KARTINI UTAMA Corrosion and Production Flow Enhancement Control Systems Company
CORROSION BASICS impressed current cp systems
Pipe Connection to pipe (return path of current) Failed coating- exposed steel CP current to pipe coating defect
Impressed Current Anodes (e.g. MMO Ti or FeSiCr)
-
+ T/R
7
PT. KARTINI UTAMA
ICCP SYSTEM
Corrosion and Production Flow Enhancement Control Systems Company
ICCP SYSTEM (TYPICAL) 50 mm Cable XLPE/PVC
DEEP GROUNDBED OVERALL=28M
POSITIVE JUNCTION BOX
@ 5 Pcs High Silicon Chromium Cast Iron Anode
TRANSFORMER RECTIFIER 30A 48V
NEGATIVE BOND BOX 50 mm Cable XLPE/PVC
50 mm Cable XLPE/PVC
PIPELINE WILL BE PROTECTED
FOREIGN PIPELINE
8
PT. KARTINI UTAMA Corrosion and Production Flow Enhancement Control Systems Company
ICCP MATERIALS
• OIL COOLED TRANSFORMER RECTIFIER • MMO Ti ANODE • 50 MM2 XLPE/PVC POSITIVE & NEGATIVE CABLE AND ACESSORIES • POSITIVE JUNCTION BOX • NEGATIVE JUNCTION/BONDING BOX • TEST POINT • 10 MM2 XLPE/PVC TEST POINT CABLE
9
PT. KARTINI UTAMA
ICCP MATERIALS: TRANSFORMER RECTIFIER
Corrosion and Production Flow Enhancement Control Systems Company
TRANSFORMER RECTIFIER DATA SHEET Applicable standard
IEC 60529
Installation area
Outdoor, Enclosure IP56
Winding type
Double winding with separated screen
Cooling type
Oil Natural
TR No.
TR-1
AC input voltage, 3 phase, 2 wires
400
V-AC
Frequency
50
Hz
AC input current
2
A-AC
DC output voltage
15
V-DC
DC output current
60
A-DC
Minimum Power to be supplied
2
KVA
Ripple Voltage
< 5.0%
Accuracy
+ 0.5%
Accessories
Built in 0-60 seconds ON/OFF timer, removable copper link to connect portable current interrupter
Manufacturer
EEME Transformer Rectifier
10
PT. KARTINI UTAMA Corrosion and Production Flow Enhancement Control Systems Company
ENCLOSURE CLASS
11
PT. KARTINI UTAMA Corrosion and Production Flow Enhancement Control Systems Company
TR: Tap Setting Oil Cooled (Based on Requisition)
ICCP MATERIALS: TRANSFORMER RECTIFIER
12
PT. KARTINI UTAMA Corrosion and Production Flow Enhancement Control Systems Company
ICCP MATERIALS: TRANSFORMER RECTIFIER
TR: Variac, Step-less (ALTERNATIVE)
13
PT. KARTINI UTAMA Corrosion and Production Flow Enhancement Control Systems Company
ICCP MATERIALS: BONDING BOX
BONDING BOX USED TO CONNECT WITH: > EXISTING PIPE > DISCONTINUOUS PIPE: Insulating Joint at LBCV, Pig Receiver, Pig Launcer > ADDITIONAL PIPE
14
PT. KARTINI UTAMA Corrosion and Production Flow Enhancement Control Systems Company
ICCP MATERIALS: BONDING BOX
Cathodic Protection Bonding Box. Enclosure: pre-galvanized sheet steel of 1.2 mm thickness. Protection: IP56, PJB will install in non-hazardous area, Door sealing: Gasket add on the door and flange plate. Painting: Internal and external epoxy powder/polyester RAL7032. Dimension: (H)600xW(400)x(D)200mm. Internal Equipment: One bus copper bar, 5 M8 studs terminal including spare with crimped lugs c/w 25 A 50 mV shunt and 600 W 3 ohm variable resistor for 5 strings of 1cx50 mm2 XLPE/PVC cable. 15
PT. KARTINI UTAMA Corrosion and Production Flow Enhancement Control Systems Company
PJB
ICCP MATERIALS: DEEPWELL GROUNDBED
Vent Pipe
To TR PVC Pipe Coke Breeze Carbon Steel Pipe MMO Ti Anode
16
PT. KARTINI UTAMA Corrosion and Production Flow Enhancement Control Systems Company
ICCP TEST POINT (Every 2 KM)
17
PT. KARTINI UTAMA Corrosion and Production Flow Enhancement Control Systems Company
CALDWELL INSULATION
ROYSTON HANDYCAP
18
XLPE INSULATION
TYPE & DESCRIPTION
N 2X Y N A 2X Y 0.6/1 KV Single + multicores. Power & control cables XLPE insulated, PVC sheathed .
N 2X R/F Gb Y N A 2X R/F GbY 0.6/1 KV Multicores power & control cables, XLPE insulated, galvanised steel wire / flat & tape armoured. PVC sheathed
STANDARD
SIZE (mm2)
1 x 1.5 s/d 500 2 x 1.5 s/d 300 3 x 1.5 s/d 300 4 x 1.5 s/d 300 SPLN 43-6 5 x 1.5 s/d 50 7 x s/d 61 x 1.5 7 x s/d 61 x 2.5 7 x s/d 61 x 4 7 x s/d 61 x 6
SPLN 43-7
APPLICATION Indoor and outdoor installation dan underground if used Digunakan untuk instalasi di dalam dan di luar gedung dan didalam tanah jika diberi pelindung cukup.
Corrosion and Production Flow Enhancement Control Systems Company
2 x 1.5 s/d 300 3 x 1.5 s/d 300 4 x 1.5 s/d 300 5 x Indoor and outdoor 1.5 s/d 50 bulling installation and 7 x s/d 61 x 1.5 7 in underground. x s/d 61 x 2.5 7 x s/d 61 x 4 7 x s/d 61 x 6
N 2X B Y NA 2X B Y 0.6/1 KV Multicores power & control cables, XLPE insulated, galvanised steel tape armoured. PVC sheathed.
1 x 1.5 s/d 500 2 x 1.5 s/d 300 3 x 1.5 s/d 300 4 x Indoor and outdoor 1.5 s/d 300 SPLN 43-8 5 x 1.5 s/d 50 7 x bulling installation and in underground. s/d 61 x 1.5 7 x s/d 61 x 2.5 7 x s/d 61 x 4 7 x s/d 61 x 6
N 2X C Y NA S 2X C Y 0.6/1 KV Multicores power & control cables, XLPE insulated and sheathed, copper wire and tape screened
2 x 1.5 s/d 50 2 x 1.5 s/d 300 3 x 1.5 s/d 300 4 x 1.5 s/d 300 Indoor and outdoor 5 x 1.5 s/d 50 7 x bulling installation and in underground. s/d 61 x 1.5 7 x s/d 61 x 2.5 7 x s/d 61 x 4 7 x s/d 61 x 6
SPLN 43-9
PT. KARTINI UTAMA
19
PT. KARTINI UTAMA Corrosion and Production Flow Enhancement Control Systems Company
Sacrificial Anode High Potential Magnesium
Magnesium installation Without SPICING KIT Caldwell insulated with Rosyton Handycap Consendate Line
Gas Line
Magnesium Anode
Test Point 20
PT. KARTINI UTAMA Corrosion and Production Flow Enhancement Control Systems Company
TEST POINT
21
PT. KARTINI UTAMA Corrosion and Production Flow Enhancement Control Systems Company
Sacrificial Anode High Potential Magnesium
As normally required, the anode is packaged in a cloth bag with a prepared backfill mixture that works to maintain moisture around the anode and lowers the anode to earth resistance. SAPMAG packaged anodes are shipped on pallets in plastic bags that must be removed prior to installation. SAPMAG Anode Chemistry* Aluminum Manganese Copper Silicon Iron Nickel Others each Magnesium
0.01% max 0.50 - 1.3% 0.02% max 0.05% max 0.03% max 0.001% max 0.05% max Remainder * Per ASTM B843 Industry Standard for M1C high potential magnesium anodes. 22