SERVICE MANUAL
MODEL :
SM-100 EDITION st
1 nd 2 rd 3 th 4
Month December March February February
Year 2004 2006 2007 2009
SHANGHAI TERAOKA ELECTRONIC CO., LTD TECHNICAL SUPPORT DEPARTMENT 1rd Floor of 2nd Building, Jia Yuan Business Center, 51# Long Wu Road, Shanghai China 200232. TEL : +86-21-6408-5151 FAX : +86-21-6408-3468 EMAIL ADDRESS :
[email protected]
Table of Content 1. GENERAL INFORMATION ........................................................................1
1.1 Overall View ...................................................................................................................................... ............. 1
1.2 Display Panel......................................................................................................................... ......................... 3
1.3 Key Panel......................................................................................................................... .................................. 3
1.4 Thermal Printer Head ............................................................................................................................ 9
1.5 Features ...................................................................................................................................... .......................10
1.6 Specification ........................................................................................................ ..........................................11
1.7 Label Type ...................................................................................................................................... ................12
2. Initial Setup .......................................................................................................... ........13
2.1 Setup ...................................................................................................................................... ..............................13
2.2 Location of Switches and Connectors .................................................................................. 15
2.3 Memory Initialisation.......................................................................................................... .................. 15
2.4 Default Specification Setting ......................................................................................................... 16
3. Calibration ................................................................................. ....................................18
3.1 Calibration Operation .......................................................................................................................... 18
3.2 Exit Calibration ............................................................................................................. .............................19
4. Software Setting ....................................................................................................... 20
4.1 Software Version Upgrade .............................................................................................................. 20
4.2 Specification Setting ..............................................................................................................................32
5. Adjustment................................................................................ ................................... 34
5.1. Peer Sensor Voltage and Label Sensor Sensitivity Adjustment....................34 5.2. Adjustment of Printing Position............................................................................................... 37 5.3. Voltage Checkpoint ..............................................................................................................................38
6. Interface .......................................................................................................... ............... 39
6.1. PC Interface ................................................................................................................. ................................39
6.2. Scale Ethernet Address ..................................................................................................................... 40
6.3. Scale IP Address ...................................................................................................................................... 41
6.4. Connection Method .............................................................................................................................42
6.5. Wire Configuration ...............................................................................................................................44
7. Miscellaneous .......................................................................................................... .. 46
7.1. Mode Change ...................................................................................................................................... .......46
7.2. Span Switch Status....................................................................................................................... ..........46
7.3. Clear All PLU Data ........................................................................................................................... ....46
7.4. Thermal Head Usage ....................................................................................................................... .... 47
7.5. IP ADDRESS ...................................................................................................................................... ......47
7.6. SERVER IP ADDRESS................................................................................................................ .. 47
7.7. SUBNET MASK ....................................................................................................................................4 7
7.8. MAC ADDRESS ................................................................................................................ ....................48
7.9. SERIAL NO ...................................................................................................................................... .........48
8.0. ASCII CHARACTER .......................................................................................................... .............. 49
8. Appendix .......................................................................................................... .................
A. SpecificationList_V200 B. FlexibleL Barcode Setting Guide C. Traceability Setting Guide D. Nutrition Setting Guide E. PC-FL1 Operation Guide F. Circuit
9. Error Message......................................................... .................
4
SM 100
1.
GENERAL
GENERAL
1.1 OVERALL VIEW
Bench Type
Pole Type
Elevated Type
11
SM 100
Bench-CS Type
Pole-CS Type
Hand Type
GENERAL
2
SM 100
GENERAL
1.2 DISPLAY PANEL
25 digits × 19 segments TN type LCD
32 × 202 full dot Matrix Green LCD
1.3
KEY PANEL
Preset Keys Type ------ B/P 32 Preset keys:
40Preset Keys:
3
SM 100
GENERAL
56 Preset Keys Type ------ PCS(New), PCS+ (New)
74 Preset Keys Type ------ EV, PCS(Old)
76 Preset Keys Type (Hanging)
4
SM 100
GENERAL
ON/OFF KEY
Turn display "ON" or "OFF". PRESET KEY
P1 ~ P40 (B/P) P1 ~ P74 (EV) P1~P32(BCS) P1~P56(PCS) P1~P76(H)
Set up or call either unit price and tare value.
NUMERIC KEYS
0~9
Enter numeric data.
TARE KEY Set or Clear Tare value. Select "NO" in S and Z Mode. Item test print in S Mode. CLEAR KEY
C
For Back space or Clear numeric value. Select "YES" in S and Z Mode.
RE-ZERO KEY
Reset weight to ZERO. PREPACK KEY
AUTO
Switch Manual mode and Pre-pack mode alternatively. (The mode status will be indicated in the P and M indicator.) ▪P - PRE-PACK MODE ▪ M - MANUAL MODE
CHANGE KEY Calculate the Changed Amount. Escape the Programming screen without saving data in S Mode.
5
MULTIPLLE KEY
X
Register the number of Non-Weight products. Select programming item such as PLU data, Shop Name in S Mode. Select Report Type in X Mode. Select Data Transaction Type in Z Mode.
CLERK KEY
V1~V4
Accumulate the Total Price.
VOID KEY
−
Correct the sales data.
PLU KEY
PLU
Call up PLU data in R Mode. Store the programmed data in S Mode.
FEED KEY
Feed Label or Receipt paper PRINT KEY
Print out Label or Receipt.
Note: BCS or PCS stands for the scale with cassette.
7
MODE SELECT KEY Five Modes can be selected using this key. •
Indicator R - REGISTRATION MODE (All the sales transactions are performed.)
•
Indicator X - CHECK MODE (Printing out and sales report.)
•
Indicator S - PROGRAM MODE (Programming preset data, such as products, data, shop name, etc.)
•
Indicator Z - TOTAL MODE (Clear sales data stored.)
•
Indicator X (Blink) - Password Setting Mode (Set PASS WORD for X, S, Z mode, set PASSWORD for PASSWORD MODE when all indicators(R, X, S, Z) blink)
Decrease/Increase Specification Count key
︽,︾
Decrease/Increase Only used when Setting SPEC 141 & 142
<<,>>
Select parameter data such as SPEC data. Move cursor left or right.
1.4 Thermal Printer Head Max Printing With: 56mm
1.5
FEATURES
Digital printing scale consists of electronic cash registers function and label printing function.
High-speed, high reliability thermal head printer.
Easy paper handing achieved special designed mechanism.
Built-in clock automatically updates data and time.
Quick response to weight changes.
Capacity and Resoultion
Capacity
3kg
6kg
12kg
15kg
30kg
1/3000S,
1/3000S,
1/3000M,
1/3000M,
1/7500S
1/6000S
12lb
15lb
30lb
60lb
1/3000S,
1/3000S,
1/3000S,
1/3000S,
1/3000M,
1/3000M,
1/3000M,
1/3000M,
1/7500S
1/6000S
1/6000S
1/6000S
1/3000S, Resolution
1/3000
1/3000M,
1/3000
1/6000S Capacity
3lb
6lb
1/3000S, Resolution
1/3000M
1/3000
1/6000S Internal count: 1/90000.
Calibrating by software.
Customer and operator display (optional customer pole display). SM-100: 25 digits x 19 segments TN type LCD with back-light for numeric digit and character display. SM-100+: 32 x 202 full dot Martix Green LCD display.
membrane keys a.
ON/OFF key
b.
10 Numeric keys, to key in numeric data.
c.
Preset keys, to preset PLU or function into the key.
d.
16 Operational keys, to perform various functional operations.
18 data files, Department, Main Group, PLU, etc.
Various reports, PLU daily report, Sales daily report,24 hours daily report, etc.
Ethernet function.
Optional wireless Ethernet bridge.
RS232C interface for data communicate and barcode scanner connection.
Optional cash drawer.
Compact housing. 9
60kg
1/3000
SM 100 1.6
GENERAL
SPECIFICATION
1.6.1 Display SM-100: 25 digits × 19 segment TN type LCD with back-light for numeric digit and character display. Tare weight display : 4 digits.
Weight display
: 5 digits.
Unit price display
: 6 digits.
Total price display
: 7 digits.
SM-100+: 32 x 202 full dot Martix Green LCD display.
Tare weight display
: 4 digits.
Weight display
: 5 digits.
Unit price display
: 6 digits.
Total price display
: 7 digits.
1.6.2 Operating Conditions Power Source
: AC 110V,220V(+10%,-15%), 50~60Hz.
Operating Temperature
: -10 °C ~ +40 °C.
Operating Humidity
: 15% ~ 85% RH.
Power Consumption
: 70 W.
1.6.3 Dimensions
Platter size Bench, Pole and Elevated : 386(W) x 270(D) mm. Bench-CS and Pole-CS
: 359(W) x 277(D) mm.
Hanging
: 274(d) x 35(h) mm.
Overall size
a)
Bench
: 386(W) x 415(D) x 127(H) mm.
b)
Pole
: 386(W) x 478(D) x 480(H) mm.
c)
Elevated
: 386(W) x 416(D) x 550(H) mm.
d)
Bench-CS
: 380(W) x 360(D) x 162(H) mm.
e)
Pole-CS
: 380(W) x 380(D) x 509(H) mm.
f)
Hand
: 340(W) x 310(D) x 544(H) mm.
10
SM 100 1.7
GENERAL
LABEL TYPE
The label diameter range is from 40 to 105 mm.
Note: Labels must be winding outwards (on top backing paper) and not inwards (under backing paper) within the core (see diagram above). If labels are wound wrongly, printing problem may result. We do not recommend the use of varnish labels.
Label Type T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 T12 S A B C F1 – F99
Dimension (mm) 28 X 56 31 X 56 34 X 56 40 X 56 43 X 56 46 X 56 49 X 56 55 X 56 37 X 56 40 X 56 43 X 56 49 X 56 28 X 37 46 X 37 46 X 37 62 X 37 Free Format
1 11
SM 100
2.
INITIAL SETUP
2.1
SETUP
INITIAL SETUP
¾ Indication of Assemble
1 13
SM 100 ¾
INITIAL SETUP
Bubble Adjustment
Bubble
Place the scale on the flat surface and adjust the four legs until the bubble on the level is in the centre as shown above.
1 14
SM 100
IINITIAL SETUP
2.2 LOCATION OF SWITCHES AND CONNECTORS
Power Switch Fuse Holder
Cash Drawer Port RS232 Port Ethernet Port
Span Switch
2.3
MEMORY INITIALISATION
To clear all memory. OPERATION
DISPLAY
REMARK
PT
kg
$/kg
$
Z1.0
RESET
SALES
DAILY
[Rezero]+[2][3][0]
CLEAR
PLU
FILE
[︾]
CLEAR
VENDER
DATA
Vender transaction data.
[︾]
CLEAR
REPORT
FILES
Report files.
[︾]
CLEAR
MEMORY
DATA
All files in memory.
[*]
CLEAR
MEMORY
Y-C N-T
[C] to clear file data,[T] to quit.
RESET
SALES
DAILY
Return to Z mode.
[C] or [T]
Z1.0
15
Z mode. Lamp Z turns on. PLU file.
SM 100
INITIAL SETUP
2.4 DEFAULT SPECIFICATION SETTING Default SPEC setting of individual country. (Please turn on the span switch before proceed this process.) ¾ Country Set OPERATION
DISPLAY
REMARK
PT
kg
$/kg
$
Z1.0
RESET
SALES
DAILY
[Rezero]+[8][8][2][2]
SPEC
2-STD
COUNTRY
[>>]
SPEC
3-CN
COUNTRY
DEFAULT
SPEC
Y-C N-T
[C]
SCALE
TYPE →
POLE
[X]
SCALE
[*]
SCALE
[X]
SCALE
[*]
SCALE
[X]
SCALE
[*]
CLEAR
MEMORY
Y-C N-T
[C] to clear memory,[T] to skip.
RESET
SALES
DAILY
Return to Z mode.
[*]
[C]
LOAD
Z1.0
TYPE → CAP. → CAP. → RES. → RES. →
BENCH 3KG 6KG 1/3000S 1/3000M
Z mode.Lamp Z turns on. Set country setting. [>>],[<<] or [X] to select country.[*] to update country setting. [C] to load default SPEC setting,[T] to skip. Set scale type. [X],[-] to select type,[*] to update type setting. Set scale capacity. [X],[ - ] to select capacity,[*] to update capacity setting. Set resolution. [X],[ - ] to select resolution,[*] to update resolution setting.
Note 1: For the first using of SM-100,Please take this operation for initialization. Note 2: Enter a number that represent a country in the country list (refer to the table below) to
initialise and country set.
SM 100
INITIAL SETUP
COUNTRY LIST No. Country Code 0 AA 1 U1 2 STD 3 CN 4 HK 5 TW 6 EX 7 KE 8 AR 9 SF 10 CS 11 GC 12 TU 13 CV 14 HG 15 PL 16 UR 17 AS 18 DM 19 FL 20 NW 21 SD 22 PG 23 UK 24 IL 25 IL (LB) 26 CA 27 CA (LB) 28 AG 29 MX 30 BZ 31 CE 32 EA 33 JD 34 LN 35 IRN 36 CR 37 TL 38 EC 39 NL 40 BG
Country Japan U.S.A. Standard China Hong Kong Taiwan Export Korea Australia And New Zealand South Africa Cyprus Greece Turkey Czech Republic Hungary Poland Russia Austria Denmark Finland Norway Sweden Portugal United Kingdom Ireland (Kg) Ireland (Lb) Canada (Kg) Canada (Lb) Argentina Mexico Brazil Chile Egypt Jordan Lebanon Iran Canary Islands Thailand European Community Netherlands Belgium
No. Country Code 41 SA 42 IC 43 IE 44 CB 45 KY 46 IR 47 VY 48 MS 49 SN 50 VZ 51 CO 52 MA 53 FR 54 WG 55 BL 56 BW 57 CP 58 LS 59 MU 60 MW 61 MZ 62 NM 63 RE 64 SH 65 SW 66 WZ 67 ZW 68 AE 69 TT 70 UD 71 LV 72 CVS 73 SK 74 SV 75 UA 76 KZ 77 IT 78 SZ 79 ID 80 CD
17
Country Saudi Arabs Iceland Indonesia Cuba Kenya Israel Slovenia Malaysia Spain Venezuela Croatia Macedonian France Germany Bulgaria Botswans Comores Lesotho Mauritius Malawi Mozambique Namibia Reunion Seychelles Swaziland Zimbabwe Zambia U.A.E Trinidad and Tobago Uganda Latvia Slovakia Sri Lanka Slovenia Ukraine Kazakhstan Italy Switzerland India New Caledonia
SM100
3.
CALIBRATION
CALIBRATION
Prior to Calibration, please refer that the specification indicating weight capacity, minimum graduation, and load cell sensitivity are correctly set. Caution: z It can only work when SPAN SWITCH is on (ENABLE). Before Calibrating, please enter Z mode.
3.1 CALIBRATION OPERATION
OPERATION
Press SPAN SWITCH
DISPLAY PT
kg
$/kg
$
Z1.0
RESET
SALES
DAILY
[Rezero]+[8][7][1][5]
After storing the zero
is
on
(ENABLE). [8][7][1][5]
while
Calibrating zero point.
CAL SP
Point ‘IR’ count Put full capacity weight
Calibrating Span.
------
on platter.[*] After calibration
SWITCH
depressing [Rezero].
------
platter,[*]
SPAN Enter
CAL 00
Ensure no weight on
REMARK
Z1.0
RESET
SALES
DAILY
18
Go back to Z mode. Lamp Z always light.
SM100
CALIBRATION
3.2 EXIT CALIBRATION
OPERATION
Press SPAN SWITCH
DISPLAY PT
kg
$/kg
$
Z1.0
RESET
SALES
DAILY
[Rezero]+[8][7][1][5] [T] [Rezero]+[8][7][1][5]
SALES
DAILY
Z1.0
RESET
on(ENABLE). [8][7][1][5]
while
Escape to Z mode. Lamp Z always light the zero point ‘IR’ count. Calibrating Span.
CAL SP
Point ‘IR’ count
is
The ‘IR’ count will be taken as
------
After storing the zero
SWITCH
depressing [Rezero].
CAL 00
[*]
[T]
RESET
SPAN Enter
CAL 00 Z1.0
REMARK
SALES
19
DAILY
Escape to Z mode. Lamp Z always light.
SM 100
SOFTWARE SETTING
4
SOFTWARE SETTING
4.1
SOFTWARE VERSION UPGRADE
Update Method Introduction SM-100 use flash RAM instead of EPROM for the main program storage of the scale. Before the boot program Version 1.10, we just have one method to update the scale’s software: PC to scale via RS232 interface. After the boot program Version 1.10 (including V1.10), we add a new method to update the scale’s software: update the scale by ethernet. So you can choose either method between these two ones to update your scale. Now we will set two parts to introduce the steps of these two updating methods.
Update Steps Introduction I. Ethernet Update Method 1. Cable & Connection There are also two ways to connect the PC and the scale in updating the scale by ethernet. 1) PC to Scale
Crossing Twisted Cable PC
Sm-100
2) Connect by Hub Normal Twisted Cable
PC
Normal Twisted Cable
HUB
20
Sm-100
These two twisted cable obey the EIT/TIA 568 standard. 1 2 3 4 5 6 7 8
T568A line series Green &White Green Orange & White Blue Blue & White Orange Brown & White Brown
1 2 3 4 5 6 7 8
T568B line series Orange & White Orange Green &White Blue Blue & White Green Brown & White Brown
crossing twisted cable: one end with T568A line series, another with T568B line series normal twisted cable: two ends both with T568B line series 2. PC Setting & Programmer Version We use “Mini Programmer (Version 2.00)” as the tool to update the scale. As it needs a default visual IP address for the PC by this kind of update method, You must set your PC’s IP address within the range of 10.10.10.1-----10.10.10.240, before you start the software to update the scale. If you don’t set the IP address like this, you can see an alarm window as Pic. 1 when you start “Mini Programmer”.
Pic. 1 3. Updating Steps 1) How to start ethernet updating? A. Turn on the switch on the bottom of the scale. B. Power off the scale by pressing On/Off Key. C. After that, press and hold [Re-Zero] and [Preset 22], then start the scale by pressing the On/Off Key. D. The screen will display the version of the current boot program for two seconds. E. Only in new versions(version of the boot program newer than 1.10), you can choose 2-ethernet. 2) Display on the scale’s screen A. If you choose 2 and the scale’s connection is correct, it will display “waiting for connect”. B. Then the message on the scale’s screen is “getting IP address”. C. After this, it will display “001 scale ready update”. D. You can’t stop it unless you press On/Off key. If you want to continue updating. You also don’t need to press any key on the scale until Mini Programmer begin to run.
3) How to upload the scale by Mini Programmer? A. Select SM-100 and press “ok”
B. Set the port
Select “ethernet” and press “OK”
C. Download boot program and update the scale Select menu “File->Load File To Programmer Buffer”
Open the source file of boot program (e.g. sm100bv100.hex)
You can see a speed mode select window here.
Select menu “Flash->Program”
Notice: The message “001 scale ready update” must be displayed on the screen of the scale before pressing the “run” button.
After the transmission has completed, select menu “File->Clear Buffer”.
Notice: 1.If the boot program of this version is already in the scale, you don’t need to upload it again, skip it and upload the main program. 2.If the scale is updated from 1.xx to 2.xx,firstly you must update the boot program of the version. D. Download main program file You must power off the scale and start the ethernet upload method again when you have finished a program uploading. The steps of uploading the main program file is also like uploading the boot program file. The file you need to open is like Pic. 2
Pic. 2
E. Download word-stock file The steps of uploading the word-stock file is also like uploading the boot program file. The file you need to open is like Pic. 3
Pic. 3 F. Download const text file The steps of uploading the const text file is also like uploading the boot program. The file you need to open is like Pic. 4
Pic. 4 G. Exit Mini Programmer Note: please update the scale according to sequence above.
RS232C Method 4. Cable Connection 3 Pins are used for data transmission between PC and SM-100 9 Pin D-Sub Female Connectors for this cable:
PC Serial Port 9 Pin D-Sub (Female)
Pin 1 2 3 4 5 6-9
Signal N.C. RXD TXD N.C. GND GND
SM-100 RS-232C 9 Pin D-Sub (Female)
Signal N.C. RXD TXD N.C. GND N.C.
Pin 1 2 3 4 5 6-9
5. Update Steps 1) How to start RS232C updating A. Turn on the switch on the bottom of the scale. B. Power off the scale by pressing the On/Off Key. C. After that press and hold [Re-Zero] & [Preset 22], then start the scale by press ing the On/Off Key. D. It will display the version of the current boot program for two seconds.
E.
If the scale boot version is newer than 1.10, it will display a updating method choice like “1-RS232 2-ETHERNET” on the screen. you can press Numeric 1 to choose 1-RS232C. If the boot version is older than 1.10, the scale will not display the choice. F. Then the Scale will display “PROGRAM”. You can’t stop it, unless you press Tare or On/Off Key. 2) Start Mini Programmer 1.
Select SM-100 and press “Ok”
2.
Set the Port:
Select RS232 and press “OK”
3.
Download the boot program and update the scale Select menu “File->Load File To Programmer Buffer”
Open the source file of the boot program (e.g. sm100bv100.hex)
Select menu “Flash->Program”
Notice: The message “001 scale ready update” must be displayed on the scale before pressing the “run” button.
After the transmission has completed, select menu “File->Clear Buffer”.
Notice: If the boot program of this version is already in the scale, you don’t need to upload it again, skip it and upload the main program.
4. Download main program file You must power off the scale and start the ethernet upload method again when you have finished a program uploading. The steps of uploading the main program file is also like uploading the boot program file. The file you need to open is like Pic. 2
Pic. 2 5. Download word-stock file The steps of uploading the word-stock file is also like uploading the boot program file. The file you need to open is like Pic. 3
Pic. 3 6. Download const text file The steps of uploading the const text file is also like uploading the boot program. The file you need to open is like Pic. 4
Pic. 4 7.
Exit Mini Programmer
4.2
SPECIFICATION SETTING Before Specification setting, please press the mode button to enter Z mode. The detail specification list , please see the appendix.
4.2.1
Customer SPEC Setting
To change setting of the Customer SPEC if there are some SPEC setting in it need to be alter. OPERATION
DISPLAY PT
kg
$/kg
$
Z1.0
RESET
SALES
DAILY
XXX
XXX
(setting)
(former)
SPEC 001
XXX
XXX
SPEC 000
XXX
XXX
[1][7]
SPEC 000
017
XXX
[X]
SPEC 017
XXX
XXX
[>>]
SPEC 017
XXX
XXX
[<<]
SPEC 017
XXX
XXX
[1]
SPEC 017
001
XXX
[*]
SPEC 018
XXX
XXX
[C]
SPEC 018
000
XXX
RESET
SALES
DAILY
[Rezero]+[1][4][1]
SPEC 000
[︾]
[︽]
[PLU] * Note 1
* Remark:
4.2.2
Z1.0
REMARK Z mode. Lamp Z turns on. Enter [1][4][1] while
depressing
[Rezero]. XXX:SPEC data [ ︾ ]key only increase specification count, it does not update SPEC data. [︽]key only decrease specification count, it does not update SPEC data. It goes to a designed specification count. (000~441 is enabled) [>>] key select SPEC data. Move cursor right. [<<] key select SPEC data. Move cursor left.
Clear the enter data. Store the updated specification and escape to Z mode.
The Weight in the display window will display the SPEC number. The Unit Price window will display the new value setting entered. The Total Price window will display the old value setting. The selection you have made will be highlighted in the dot matrix display. Please use [︾] to increase spec count, [︽] to decrease spec count, [*] to store a new value and [PLU] to save spec setting.
Weight & Measurement SPEC Setting
To change the setting of the Weight & Measurement SPEC if there are some SPEC need to alter. (Please turn on the span switch when using this process) OPERATION
DISPLAY
REMARK
PT
kg
$/kg
$
Z1.0
RESET
SALES
DAILY
XXX
XXX
(setting)
(former)
SPEC 601
XXX
XXX
SPEC 600
XXX
XXX
[6][1][5]
SPEC 600
615
XXX
[X]
SPEC 615
XXX
XXX
[>>]
SPEC 615
XXX
XXX
[<<]
SPEC 615
XXX
XXX
[1]
SPEC 615
001
XXX
[*] key to update specification,
[*]
SPEC 616
XXX
XXX
increase specification count.
[2]
SPEC 616
002
XXX
[C]
SPEC 616
000
XXX
RESET
SALES
DAILY
Press SPAN SWITCH [Rezero]+[1][4][2]
SPEC 600
[︾]
[︽]
[PLU] * Note 1
Z1.0
SPAN SWITCH is on(ENABLE). Enter [1][4][2] while
depressing
[Rezero]. XXX:SPEC data [ ︾ ]key only increase specification count, it does not update SPEC data. [︽]key only decrease specification count, it does not update SPEC data. It goes to a designed specification count. (600~709 is enabled) [>>] key select SPEC data. Move cursor right. [<<] key select SPEC data. Move cursor left.
Clear the enter data. Store the updated specification and escape to Z mode.
Note 1: If press [T] key, it does not store the updated specification and escape to Z mode.
* Remark:
The Weight in the display window will display the SPEC number. The Unit Price window will display the new value setting entered. The Total Price window will display the old value setting. The selection you have made will be highlighted in the dot matrix display. Please use [︾] to increase spec count, [︽] to decrease spec count, [*] to store a new value and [PLU] to save spec setting.
SM100
ADJUSTMENT E
5.
ADJUSTMENT
5.1
PEEL SENSOR VOLTAGE AND LABEL SENSOR SENSITIVITY ADJUSTMENT
Label Sensor
LOCATION OF PEEL AND LABEL SENSOR
SM100 5.1.1
ADJUSTMENT
Peel Sensor Voltage
To set the peel sensor voltage if the peel sensor is not working normally in some situations like temperature and humidity change. OPERATION
DISPLAY PT
kg
$/kg
$
Z1.0
RESET
SALES
DAILY
REMARK Z mode. Lamp Z turns on. Enter [5][1][5] while depressing
[Rezero]+[5][1][5]
PEEL
PFD
0.5
0.0
[Rezero]. ﹩/kg window displays label paper peel sensor voltage, ﹩ window displays new setting value.
[T]
5.1.2
Z1.0
RESET
SALES
DAILY
[T] key to exit.
Label Sensor Sensitivity
Adjust here for sensor
When the label came out three or more when feeding or printing, the sensitivity of the sensor need to be adjusted to sense the gap between the label better. There is a variable resistor near the sensor. Adjust it to increase or decrease the sensitivity. Clockwise is to increase the sensitivity and anti-clockwise is to decrease the sensitivity.
SM100
ADJUSTMENT
OPERATION
DISPLAY PT
kg
$/kg
$
Z1.0
RESET
SALES
DAILY
REMARK Z mode. Lamp Z turns on. Enter [5][1][6] while depressing [Rezero]. ﹩/kg window
[Rezero]+[5][1][6]
GAP
PFD
2.0
3.1
displays label paper gap sensor voltage, ﹩window displays new setting
[T]
Z1.0
RESET
SALES
DAILY
value. [T] key to exit.
SM100 5.2
ADJUSTMENT
ADJUSTMENT OF PRINTING POSITION
This function is used to adjust the print position on label. OPERATION
DISPLAY PT
kg
$/kg
$
Z1.0
RESET
SALES
DAILY
REMARK Z mode. Lamp Z turns on. Enter [5][1][4] while
[Rezero]+[5][1][4]
ADJ
PFD
0
0
depressing
[Rezero]. ﹩/kg window display old setting, ﹩ window display new setting. To move up the point position on
[1][0]
ADJ
PFD
0
10
label, enter the new value by numeric key (Ex. 10 dots). If you want to move down the print
[1][0][-]
ADJ
PFD
0
-10
position, please enter the new value by numeric key (Ex. 10dots), and then press [−] key.
[PLU]
0.000
0.000
0.00
0.00
[T]
Z1.0
RESET
SALES
DAILY
PRINTING TOO HIGH (ADJUST DOWNWARD)
CORRECT POSITION
Save the feed setting. If you want to exit without saves the setting, press [T] key to exit.
PRINTING TOO LOW (ADJUST UPWARD)
SM100 5.3
ADJUSTMENT
VOLTAGE CHECKPOINT
There are several voltage checkpoints on the PCB boards. Below are some reference voltage points that are commonly use. VOLTAGE POINT VCC
VOLTAGE 3.3 V
PURPOSE Provide voltage for most of the IC
VTH
24 V
Provide voltage mainly to the thermal head
VBB
3V
Provide backup voltage for the RAM IC
HVcc
5V
The tolerance of all the voltage is about ± 5% except VTH is +2% and -5%
SM100
6.
INTERFACE
6.1
PC INTERFACE
INTERFACE
SM 100 can be connect to PC through Ethernet interface and RS232C. See below for the connection method. CONFIGURATION OF PC ETHERNET CARD Window version client driver Any Ethernet cards can be used for PC running the Window version client driver Windows 98 My Computer → Control Panel → Network→TCP/IP of Ethernet card (Select Properties) IP address : 192.168.1.XXX ------ XXX - can be any number. But preferable 100 to 255. Submask : 255.255.255.0 Above IP address is use as a standard address to use for SM 100 Ethernet communication. If whatever reason, the IP address had to be change, it may do so. But the scale IP address had to be change at the SM 100 scale also so that they are within the same network. Eg. If the computer IP address is 192.168.1.XXX, the SM 100 scale IP address has to be change to 192.168.1.XXX. The last three digits of the IP address should not be similar within the computer and scales at all time. As can see the first three set of number of the IP address of the computer and scale must be the same.
39
SM100
INTERFACE
Before setting the SPEC setting of the scale, please check below.
6.2
SCALE ETHERNET ADDRESS
The main board have a Scale Ethernet Address that is set during production. This address is a hardware setting for Ethernet communication. But when changing a new main board, the new main board did not have any this address. If the scale is using Ethernet communication, a Scale Ethernet Address is needed apart from software IP address. Please take note that the Scale Ethernet Address can only input once after saving. Please view and note down the Scale Ethernet Address of the old main board before changing the new main board. Below procedure is to view and input the Scale Ethernet Address. Please turn on the span switch before proceed. KEY TO PRESS PT
kg
DISPLAY $/kg
OPERATION $
Go to Z mode [REZERO] + [0][6][1][2]
Z1.0 ETHER
RESET NET
SALES …….
Daily …….
[0][0][0][6][C][0] [0][0][0][0][2] [4] [PLU]
ETHER
NET
0006C
0000024
Z1.0
RESET
SALES
Daily
[T]
Z1.0
RESET
SALES
Daily
Power off the scale * IMPORTANT :
6.3
At Z mode Viewing of Ethernet address For new main board, it can act as input of the address if the address shown …….. Else it would not let you to input. For input only. Enter Ethernet address e.g. 0006C 0000024 Save address and escape to Z mode. After saving it will not be able to input again. Escape to Z mode without saving. Turn off the power and do the memory clear process.
Please take note that this is a one time setting. It cannot be change after setting it. Please check the old address and input accordingly. As same internal Ethernet address in a network may conflict during communication.
SCALE IP ADDRESS 40
SM100
INTERFACE
This is to set the IP address for PC communication using Ethernet for specific IP address. It should not be confused with the Scale Ethernet Address as above. The Scale Ethernet Address is mainly for hardware and Scale IP Address is for software. The software when communicating to the scale must specify the same IP address on the scale else it will give error. The default is 192.168.000.000 where the last three digit will change when SPEC 135 change. Please turn on the span switch before proceed. KEY TO PRESS PT
kg
DISPLAY $/kg
OPERATION $
Go to Z mode [REZERO] + [0][4][1][6] [1][9][2][1][6][8] [0][0][1][0][1][6]
Z1.0 SCALE
RESET IP
SALES …….
Daily …….
SCALE
IP
192168
001016
[PLU]
Z1.0
RESET
SALES
Daily
[T]
Z1.0
RESET
SALES
Daily
41
At Z mode Input or viewing of IP address Enter IP address e.g. 192.168.001.016 ( The last 3 digits cannot be input as it will change when SPEC 135 change) Save address and escape to Z mode Escape to Z mode without saving.
SM100 6.4
INTERFACE
CONNECTION METHOD
6.4.1 RS232C Interface with PC PC
Scale
Com 1 / Com 2
RS232C Port
* Note : Only 1 scale can be connect in this method. SPEC setting on scale : SPEC 48
Scale number (For 4 line / RS232C port)
Enter number between 1 to 999,999
SPEC 51 0 1
1200 2400
6
76800
SPEC 52 0
7 bit
SPEC 53 0
None
SPEC 54 0
1 bit
Baud rate for SIO (RS232C port) 2 3
4800 9600
4 5
19200 38400
2
Even
Data length for SIO (For RS232C port) 1
8 bit
Parity for SIO (For RS232C port) 1
Odd
Stop bit for SIO (For RS232C port) 1
2 bits
6.4.2 Ethernet Connection (Ethernet Interface) 42
SM100
INTERFACE
Scale #1
Scale #2
Scale #3
Scale #4
Scale #5
PC HUB
SPEC setting on scale : SPEC 49 0 1 2
SPEC 50 0 1
CLIENT / SERVER INTERFACE
No interface Ethernet - Coaxial Cable Ethernet - Twisted Cable
Not used 4 lines, RS485 (For future use)
2
Back-up server
CLIENT / SERVER
Client Server / Workstation
SPEC 135
3 4
PORT NUMBER
* Enter number from 1 to 254
43
SM100 6.5
INTERFACE
WIRE CONFIGURATION
6.5.1 Ethernet Wire - Straight Cable and Crossover Cable Straight cable is for Client / Server connection. Crossover cable is for Hub to Hub connection. (Some models of the hub do not need crossover cable for hub to hub connection. Please refer to the hub operation manual if in doubt) Telephone Modular Plug (Category 5) -
Preferable type :
CviLux CJP3 / CviLux CJP4 (with insert bar)
CABLE TYPE Cable type
:
4 pair 100MHz Cat.5 AWG 24 or 26 UTP / FTP / STP.
Preferable type :
Cat. 5 AWG 24 or 26 FTP / Cat. 5 AWG 24 or 26 STP (Recommended for CISPR 22B conformance)
PIN CONFIGURATION 1
8
SM 100
HUB 8
1 Solder to braid wire of the Ethernet wire if using plug without insert bar
1
8
SM 100 8
HUB Solder the braid wire of the Ethernet wire if using plug with insert bar
STRAIGHT CONNECTION SCALE PIN SIGNAL 1 TX+ 2 TX3 RX+ 6 RX5,7,8 N.A.
1 CROSSOVER CONNECTION
HUB
HUB
SIGNAL PIN TX+ 1 TX2 RX+ 3 RX6 N.A. 5,7,8
PIN SIGNAL 1 TX+ 2 TX3 RX+ 6 RX5,7,8 N.A.
44
HUB SIGNAL PIN TX+ 3 TX6 RX+ 1 RX2 N.A. 5,7,8
SM100
INTERFACE
6.5.2 RS232C Wire PC (9 PIN) TO SCALE RS232C PORT
RS232C Port(9 Pin)
Pin 1 2 3 4 5 6 7 8 9
PC COM Port(9 Pin) PC
RS-232 输出
输入 Not used TXD RXD Not used GND Not used Not used Not used Not used
Not used RXD TXD DTR GND DSR DTR DSR Not used
6.5.3 Cash Drawer Connector SM-100 uses normal phone mike plug to connect cash drawer and the scale. 1 pin
1 pin
4 pin
4 pin
Plug in the scale Pin Output 1 Not used. 2 +8V 3 GDD 4 Not used.
Connector of Cash Drawer Input Pin Not used 1 Voltage + 2 GDD 3 Not used 4
45
Pin 1 2 3 4 5 6 7 8 9
SM 100
MISCELLANEOUS
7.
MISCELLANEOUS
7.1
MODE CHANGE
To toggle between R, X, S, Z and Password mode. OPERATION
DISPLAY PT
kg
$/kg
$
0.000
0.000
0.00
0.00
[MODE],[MODE]
XMODE
(within 3 seconds)
REMARK Weight mode.Lamp R turns on. Enter X mode.Lamp X turns on.
[MODE]
S1
→
PLU
FILE
Enter S mode.Lamp S turns on.
[MODE]
Z1.0
RESET
SALES
DAILY
Enter Z mode.Lamp Z turns on.
PWD X
0
SET
0.000
0.00
0.00
[MODE] [MODE]
0.000
Enter Password Set mode.Lamp X flicker Back to Weight mode.Lamp R turns on.
** The “X ” mark on the X, S, Z and R mean the indicator light is on. When in Passwomode, indicator light will be blinking.
7.2
the
SPAN SWITCH STATUS
To check the status of the span switch. OPERATION
Go to Z mode
DISPLAY PT
kg
$/kg
$
Z1.0
RESET
SALES
DAILY
STE16
VX.XX
S-OFF
RESET
SALES
DAILY
[Rezero]+[2][8][4] Z1.0
7.3
REMARK Z mode. Lamp Z turns on. Enter
[2][8][4]
while
depressing
[Rezero]. Exit after 3 seconds.
CLEAR ALL PLU DATA
To clear all the PLU data only, the span switch status must be on. OPERATION
DISPLAY PT
kg
$/kg
$
Z1.0
RESET
SALES
DAILY
[Rezero]+[2][3][0]
CLEAR
PLU
FILE
*
CLEAR
PLU
Y--C N--T
RESET
SALES
DAILY
Go to Z mode
C(T)
7.4
Z1.0
THERMAL HEAD USAGE 46
REMARK Z mode. Lamp Z turns on. Enter
[2][3][0]
while
depressing
[Rezero]. Enter C for Yes, Enter T for No.. Back to Z mode
SM 100
MISCELLANEOUS
To check how many time the thermal head had been printing. OPERATION
Go to Z mode
DISPLAY PT
kg
$/kg
$
Z1.0
RESET
SALES
DAILY
PRINTER
USAGE
5
RESET
SALES
DAILY
[Rezero]+[0][8][2][3] [T]
7.5
Z1.0
REMARK Z mode. Lamp Z turns on. Display thermal printer usage condition(meter). [T] key to exit.
IP ADDRESS
To check and modify the scale IP address. DISPLAY
OPERATION
Go to Z mode [Rezero]+[0][4][1][6] [1][9][2][0][0] [9][1][0] [0]
PT
kg
$/kg
$
Z1.0
RESET
SALES
DAILY
SCALE
IP
19216800
0000
SCALE
IP
19200910
0000
[#]
7.6
----------
REMARK Z mode. Lamp Z turns on. Display the scale IP address. Modify the IP address. Save the new IP address. Press [T] key to exit.
SERVER IP ADDRESS
To check and modify the server IP address. OPERATION
Go to Z mode [Rezero]+[0][4][1]7] [1][9][2][0][0] [9][1][0] [0]
DISPLAY PT
kg
$/kg
$
Z1.0
RESET
SALES
DAILY
SERVER
IP
25525525
5000
SCALE
IP
19200910
0000
[#]
7.7
----------
SUBNET MASK 47
REMARK Z mode. Lamp Z turns on. Display the server IP address. Modify the server IP address. Save the new IP address. Press [T] key to exit.
SM 100
MISCELLANEOUS
To check and modify the subnet mask. DISPLAY
OPERATION
Go to Z mode [Rezero]+[0][4][1]8] [1][9][2][0][0] [9][1][0] [0]
PT
kg
$/kg
$
Z1.0
RESET
SALES
DAILY
SERVER
IP
25525525
5000
SCALE
IP
19200910
0000
[#]
REMARK Z mode. Lamp Z turns on. Display the server IP address. Modify the server IP address. Save the new IP address.
----------
7.8
Press [T] key to exit.
MAC ADDRESS
To check the MAC address. Please turn on the span switch before proceed. DISPLAY
OPERATION
Go to Z mode
[Rezero]+[0][6][1]2] [T]
7.9
PT
kg
$/kg
$
Z1.0
RESET
SALES
DAILY
ETHERN ET Z1.0
0006C071
96BE
SALES
DAILY
RESET
REMARK Z mode. Lamp Z turns on. Display the MAC address. Press [T] key to exit.
SERIAL NO
To check the serial NO.. DISPLAY
OPERATION
Go to Z mode
PT
kg
$/kg
$
Z1.0
RESET
SALES
DAILY
SCALE
S/N
05386686
RESET
SALES
DAILY
[Rezero]+[1][1][1] [T]
Z1.0
REMARK Z mode. Lamp Z turns on. Display the serial NO.. Press [T] key to exit.
8.0 ASCII CHARACTER Below are the common use of characters of ASCII code in HEX value. Please enter the hex value when entering commodity name, advertisement, shop name, clerk name, special message, ingredient, text etc. when using the SM-100. A
B
C
D
E
F
G 48
H
I
J
K
L
M
SM 100
MISCELLANEOUS 41 N 4E a 61 n 6E 0 30 $ 24 > 3E
42 O 4F b 62 o 6F 1 31 % 25 = 3D
43 P 50 c 63 p 70 2 32 ^ 5D / 2F
44 Q 51 d 64 q 71 3 33 & 26 ? 3F
45 R 52 e 65 r 72 4 34 * 2A · 2E
46 47 48 S T U 53 54 55 f g h 66 67 68 s t u 73 74 75 5 6 7 35 36 37 : ( ) 28 29 3A Space , 2C 20
49
49 V 56 i 69 v 76 8 38 ; 3B
4A W 57 j 6A w 77 9 39 " 22
4B X 58 k 6B x 78 ! 21 ' 27
4C Y 59 l 6C y 79 @ 40 + 2B
4D Z 5A m 6D z 7A # 23 < 3C
Specification List
TITLE REVISION NO. ISSUED DATE Rev. No. 0
nd
2
SM-100 V2.00
: : :
26 December, 2006
SM-100 SPECIFICATION LIST 0 17 August, 2004 Modification Details
First Release
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.
Software Version 1.00
1 of 32
Specification List SPEC NO.
SM-100 V2.00
26 December, 2006
SPECIFICATION DESCRIPTION
SM-100
CUSTOMER SPECIFICATION [REZERO] + [1][4][1] 00
01
02 03 04 05 06 07
08
09 10 11
12 13 14 15 nd
2
Item Barcode 0 F1F2 CCCCC XCD XXXX CD 1 F2 CCCCCC XCD XXXX CD 2 F1F2 CCCCC 0 XXXX CD 3 F1F2 CCCCCC XXXX CD 4 F1F2 CCCCC XXXXX CD 5 F2 CCCCCC XXXXX CD 6 F2 CCCCC XXXXXX CD 7 F1F2 CCCCCCCCCC CD #1 8 F1F2 CCCC XXXXXX CD 9 F1F2 CCCCC CD #2 10 F2 CC XXXX CD #3 11 No Barcode 12 F1X2 CCCCC XCD XXXX CD Right Side Data of Item Barcode 0 Quantity 1 Price 2 Weight 3 User Programmable # Right Side Price Data of Item Barcode 0 Price before Tax
9 13 14 15 16 17 18 19 20
F1X2 CCCCCC XXXX CD F1F2 CCCC XCD XXXXX CD F2 CCCCC XCD XXXXX CD F1F2 CCC XXXXXXX CD F1F2 CC XXXXXXXX CD CCC WWWW PPPPP CD No Barcode F1F2 CCCCC PCD XXXX CD
4 5 6 7
Original Price Weight / Quantity Unit Price Unit Price after discount
1
Price after Tax
All are 13 digits non-PLU barcode unless otherwise stated. #1 13 digits PLU barcode #2 8 digits PLU barcode #3 8 digits non-PLU barcode
9 # Related to SPEC153.
9 Effective when SPEC1 = 1
Flag Data F1 and F2 for 13 Digits Non-PLU Barcode Enter value from range 0 to 99 Flag Data F1 and F2 for 13 Digits PLU Barcode Enter value from range 0 to 99 Flag Data F2 for 8 Digit Non-PLU Barcode Enter value from range 0 to 9 Flag Data F1 and F2 for 8 Digit PLU Barcode Enter value from range 0 to 99 Total Barcode 0 F1F2 CCCCC XCD XXXX CD 12 F1X2 CCCCC XCD XXXX CD 1 F2 CCCCCC XCD XXXX CD 13 F1X2 CCCCCC XXXX CD 2 F1F2 CCCCC 0 XXXX CD 14 F1F2 CCCC XCD XXXXX CD 3 F1F2 CCCCCC XXXX CD 15 F2 CCCCC XCD XXXXX CD 4 F1F2 CCCCC XXXXX CD 16 F1F2 CCC XXXXXXX CD 5 F2 CCCCCC XXXXX CD 17 F1F2 CC XXXXXXXX CD 6 F2 CCCCC XXXXXX CD 18 CCC WWWW PPPPP CD 7 F1F2 CCCCCCCCCC CD #1 19 No Barcode 8 F1F2 CCCC XXXXXX CD 20 F1F2 CCCC PCD XXXX CD 9 F1F2 CCCC CD #2 10 F2 CC XXXX CD #3 11 No Barcode Left Side Data of Total Label 0 Scale No. 3 Clerk No. 1 Last Accumulated Item Code 4 Fixed No. 2 Receipt No. Fixed Data for Left Side Data of Total Barcode Enter value from range 0 to 9 999 999 999 Flag Data F0, F1 and F2 for Total Barcode Enter value from range 0 to 999 Right Side Data of Total Barcode 0 Quantity 2 Weight 1 Price
9
Total Barcode Print on Receipt 0 No 1 Yes Print Readable Character of F1 for Item and Total Barcode (for EAN only) 0 No Print 1 Print
9
Printing Position for Advertisement Message 0 First Line 2 Above 1 Below 3 Not Used Turnover Printing for Advertisement Message 0 No 1 Yes
9
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.
9 9 9 9 All are 13 digits non-PLU barcode unless otherwise stated. #1 13 digits PLU barcode #2 8 digits PLU barcode #3 8 digits non-PLU barcode
9
9 9 9
8
2 of 32
Specification List 16
17 18 19
20 21 22 23 24
25
26 27 28 29 30 31 32
33 34 35
nd
2
SM-100 V2.00
26 December, 2006
Exit from “Change” Mode within Specified Interval 0 No 3 10 sec 1 3 sec 4 15 sec 2 6 sec Order of the Month, Day and Year for Print 0 MM/DD/YY 2 YY/MM/DD 1 DD/MM/YY 3 Not Used 1 or 2 Line(s) Commodity Name on Receipt 0 2 Lines 2 No Print 1 1 Line Label Printing by Clerk Key 0 No Print 2 Print without Accumulated 1 Print with Accumulation Total Label Printing 0 No Print 1 Print Printing Operator Name on Receipt and Label 0 Code 1 Name Receipt Paper Width 0 60 mm 2 50 mm 1 40 mm Manual Price Entry for Printing or Accumulating 0 Allow 1 Inhibit Default Label Format for Item Printing 0 T1 (A) 12 S (T7) 1 T2 (B) 13 A (T8) 2 T3 (C) 14 B (T9) 3 T4 (U2) 15 C (T10) 4 T5 (U3) 16 F1 (F1) 5 T6 (U4) 17 F2 (F2) 6 T7 (U5) 18 F3 (F3) 7 T8 (U6) 19 F4 (F4) 8 T9 (U7) 20 F5 (F5) 9 T10 (U8) 21 F6 (F6) 10 T11 (T5) 22 F7 (F7) 11 T12 (T6) 23 F8 (F8) Default Label Format for Total Printing 0 T1 (A) 12 S (T7) 1 T2 (B) 13 A (T8) 2 T3 (C) 14 B (T9) 3 T4 (U2) 15 C (T10) 4 T5 (U3) 16 F1 (F1) 5 T6 (U4) 17 F2 (F2) 6 T7 (U5) 18 F3 (F3) 7 T8 (U6) 19 F4 (F4) 8 T9 (U7) 20 F5 (F5) 9 T10 (U8) 21 F6 (F6) 10 T11 (T5) 22 F7 (F7) 11 T12 (T6) 23 F8 (F8) Shop Name Printing on Label 0 No Print 1 Print Forced Tare Function 0 Disable 1 Enable Peel Sensor Function in Prepack Mode 0 Disable 1 Enable Continuous Print for Label in Prepack Mode 0 Inhibit 1 Allow Selection of CDV 0 Inhibit 1 Allow CDV Type 0 CDV 1 Tear-off CDV Modulus 0 Modulus 10 1 Modulus 11
9
On Spot Correction 0 Allow Search Correction 0 Allow Move Back Correction 0 Allow
9 1
Inhibit
1
Inhibit
1
Inhibit
9
9
9
9 9 8
9 9 Formats in ( ) are for U1 and CA only. F1 to F8 are Free Format.
9 Formats in ( ) are for U1 and CA only. F1 to F8 are Free Format.
9 9 9 9 8 For SF only.
8 For SF only.
8 For SF only. Effective when SPEC30 and 31 = 1.
8 9
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.
3 of 32
Specification List 36 Past Sales Data Correction 0 Allow 37 Label Print Density 0 Low 1 Mid 38 Receipt Print Density 0 Low 1 Mid 39 40 41 42 43 44 45 46 47 48 49
50
51
52
53
54
55
56 57
58
nd
2
SM-100 V2.00 1
Inhibit
2 3
High-mid High
2 3
High-mid High
26 December, 2006 9
9
Calling of PLU 0 Manual 2 Time-out 1 Auto PLU Digits for Auto PLU Calling/Time-out Calling 0 3 Digits / 0.5 sec 2 5 Digits / 1.5 sec 1 4 Digits / 1.0 sec 3 6 Digits / 2.0 sec Unit Price of Weigh PLU Can Use for Price of Non-weigh PLU and Vice Versa 0 Allow 1 Inhibit
9
Unit Price Override 0 Allow 1 Inhibit Main Usage for Commodity Name, Shop Name and Special Message 0 Receipt 1 Label
9
Tare Override 0 Allow 1 Inhibit Item Printing 0 Allow 1 Inhibit Default Data of Printing Shop Name Number for Label Enter value from range 0 to 32 Default Data of Printing Shop Name Number for Receipt Enter value from range 0 to 32 Setting of Scale Number Enter value from range 0 to 999 999 Type of Client / Server Interface 0 No Interface 3 Not Used 1 Ethernet (Coaxial Cable) 4 4-Lines (RS-485) 2 Ethernet (Twisted Pairs) Setting of Client / Server 0 Client 2 Backup Server 1 Server / Workstation
9
Baud Rate of SIO (RS-232C Port) 0 1 200 bps 1 2 400 bps 2 4 800 bps 3 9 600 bps
9
Data Length of SIO (RS-232C Port) 0 7 Bits Parity Bit of SIO (RS-232C Port) 0 None 1 Odd Stop Bit of SIO (RS-232C Port) 0 1 Bit
4 5 6
19 200 bps 38 400 bps 76 800 bps
1
8 Bits
2
Even
1
2 Bits
Related to SPEC40.
9 Effective when SPEC39 = 1.
9 Effective when SPEC643 = 0.
9 Always set to 0 for SM200.
9 9 9 9 9 Related SPECs for Ethernet I/F are SPEC50, 135, 214.
9 Related SPECs for S/C setting are SPEC61, 150, 163, 165, 187, 194, 208, 229, 252, 253, 254, 255, 265, 276. Apply to both RS-232C and RS-485 ports setting for SM-300. Related SPECs are SPEC48, 52, 53, 54, 60, 134.
9 Apply to both RS-232C and RS-485 ports setting for SM-300.
9 Apply to both RS-232C and RS-485 ports setting for SM-300.
9
Baud Rate of Multi-drop SIO (RS-485 / 4-Lines Port) 0 1 200 bos 3 9 600 bps 1 2 400 bps 4 19 200 bps 2 4 800 bps 5 38 400 bps Data Length of Multi-drop SIO (RS-485 / 4-Lines Port) 0 7 Bits 1 8 Bits Parity Bit of Multi-drop SIO (RS-485 / 4-Lines Port) 0 None 2 Even 1 Odd Stop Bit of Multi-drop SIO (RS-485 / 4-Lines Port) 0 1 Bit 1 2 Bits
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.
Apply to both RS-232C and RS-485 ports setting for SM-300.
8 Related SPECS are SPEC48, 56, 57, 58, 59, 134.
8 8
8
4 of 32
Specification List SM-100 V2.00 59 Multi-drop SIO (RS-485 / 4-Lines Port) Select Job 0 No Operation 2 Pick ‘N’ Pay #2 1 FIS 3000 #1 60
61 62 63 64 65
nd
2
SIO (RS-232C Port) Select Job 0 No Operation 1 FIS 30000 #1 2 FL-1
26 December, 2006 8 #1 Either SPEC59 or 60 can be selected at any one time. #2 For SF only.
8 3 4 5
Point ‘N’ Shop Barcode Scanning Video Control #2
Floating Clerk 0 Inhibit 1 Allow Receipt Free Format 0 Disable 1 Enable SM-90 and DI-10 RS-232C Communication 0 No 1 Yes Enable Password Mode 0 Allow 2 Allow Multi Password 1 Inhibit Report Printing in Daily and Term Transaction Clear 0 Inhibit 1 Allow
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.
Apply for both RS-232C and RS-485 ports setting for SM-300. #1 Refer to SPEC59’s comments #1. #2 For SM-300 only
8 8 Exclude AA.
8 9
9
5 of 32
Specification List SM-100 V2.00 66 Pack Quantity Function Key Enable 0 Allow 1 Inhibit 67 Advertisement Function Key Enable 0 Allow 1 Inhibit 68 Fixed Total Price Discount Function Key Enable 0 Allow 1 Inhibit 69 Total Price Percentage Discount Function Key Enable 0 Allow 1 Inhibit 70 Fixed Unit Price Function Key Enable 0 Allow 1 Inhibit 71 Fixed Unit Price Percentage Function Key Enable 0 Allow 1 Inhibit 72 Pack Date Function Key Enable 0 Allow 1 Inhibit 73 Minus Pack Date Function Key Enable 0 Allow 1 Inhibit 74 Sell by Date Function Key Enable 0 Allow 1 Inhibit 75 Unit Symbol Function Key Enable 0 Allow 1 Inhibit 76 Quantity Set Function Key Enable 0 Allow 1 Inhibit 77 Price Change Function Key Enable 0 Allow 1 Inhibit 78 Refund Item Function Key Enable 0 Allow 1 Inhibit 79 Shop Name Function Key Enable 0 Allow 1 Inhibit 80 Logo Function Key Enable 0 Allow 1 Inhibit 81 Print Select Function Key Enable 0 Allow 1 Inhibit 82 Print of Place of Production on Label 0 Inhibit 1 Allow 83 Selection of Markdown 0 No Markdown 2 Total Price Markdown 1 Unit Price Markdown 3 Unit and Total Price Markdown 84 Sub-total Function Key Enable 0 Allow 1 Inhibit 85 Grand Total Function Key Enable 0 Allow 1 Inhibit 86 Label Sensor Gap Value Enter value range from 0 to 255 87 Label Type 0 Gap 1 No Gap 88 Sell by Date Title Print out 0 Inhibit 1 Allow 89 ASCII Code Entry in S Mode 0 Inhibit 1 Allow 90 91 92
93
94 95 96 97 nd
2
Sub-total Markdown 0 No Markdown 1 Printer Speed for Receipt 0 Slow 2 1 Normal Printer Speed for Label 0 Slow 2 1 Normal Printer Strode 0 Single 2 1 Double Print Second Receipt 0 No Print 3 1 Continuous Print 4 2 1 sec Delay Position of Currency Symbol (on Label) 0 Before Price 1 Receipt Printing with Dual Copy 0 Inhibit 1 Advertisement Message on All Label 0 Inhibit 1 Manual Print in Prepack Mode for Weigh Item
26 December, 2006 9 9 9 9 9 9 9 9 9
9 9 9 9 9 9
9 9 8 9 8 For AA only.
8 For AA only.
9 Markdown 9 High 9 High 8 Not Used 9 3 sec Delay User Select 9 After Price 8 Allow 9 Allow
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.
9 6 of 32
Specification List SM-100 V2.00 0 Inhibit 1 Allow 98 Quantity and Unit Symbol Print Out for Non-weigh Item in Manual Mode 0 Allow 1 Inhibit 99 Unit Print Out for Non-weigh Item in Manual Mode 0 Inhibit 1 Allow 100 Discount in PLU Programming 0 Allow 1 Inhibit 101 Zero Suppress for Date and Time 0 Disable 1 Enable 102 Discount Presentation in Receipt 0 Discounted Unit Price and 1 Original Unit Price and Price Original Price 103 Unit Price Assignment Function Key for PLU 0 Enable 1 Disable 104 Discount Price Rounding Method 0 Rounding 2 Cut Up 1 Cut Down 105 Fixed Total Price Markdown Function Key Enable 0 Allow 1 Inhibit 106 Total Price Percentage Markdown Function Key Enable 0 Allow 1 Inhibit 107 Fixed Unit Price Markdown Function Key Enable 0 Allow 1 Inhibit 108 Fixed Unit Price Percentage Markdown Function Key Enable 0 Allow 1 Inhibit 109 Source of Sell by Date 0 Real Time Clock 1 Packed Date 110 Year Type 0 Standard 1 Japanese / Taiwan 111 Price Symbol on Receipt 0 No Print 2 Yen 1 Kanji Yen 112 Default Data of Printing Special Message Number for Receipt Enter value range from 0 to 16 113 Label Logo Printing Status 0 No Print 3 Logo 3 1 Logo 1 4 Logo 4 2 Logo 2 114 Receipt Logo Printing Status 0 No Print 4 Logo 3 1 Logo 1 5 Logo 4 2 Logo 2 6 Logo 1, 2, 3 and 4 3 Logo 1 and 2 115 Type of Entry for Used by Date and Sell by Date 0 By Day 1 By Hour 116 Barcode Printing in First Label for Dual Label Printout 0 Print 1 No Print 117 Zero Minutes Printing 0 No Print 1 Print 118 119
120 121 122 123 124 125 126 127 nd
2
Both Price before and after Discount 0 Price before and after Discount Unit Symbol Printout in Receipt 0 Depend on PLU Programming 1 Japanese PCS PLU Number Print 0 No Zero Suppress Thick Japanese Character Printout 0 Thick Character Prepare Mode after Power On 0 Manual Mode Printing Thank You Message on Receipt 0 Enable PLU Unit Price after Discount 0 Unit Price after Discount Position of Special Message on Receipt 0 Bottom Function Keys Protection for Self-service 0 No Protection 1 Full Protection Printing of Checksum for Item Barcode
26 December, 2006 9 8 8 9 8
9
9 9 9 9 9 8 For AA and TW only.
8 For AA only.
9 9
8 For NICHII only.
8 For NICHII only.
8 For NICHII only.
8 1
Price before Discount only
2
No Print
1
Zero Suppress
1
Thin Character
1
Prepack Mode
1
Disable
1
Unit Price Discount Amount
1
Top
2
Partial Protection
For NICHII only.
9 For AA only.
9 8 For AA only.
8 Always set to 0 for SM200.
8 9 9 8
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.
7 of 32
Specification List SM-100 V2.00 0 Disable 1 Enable 128 Setting of Host Number (For SM-15 Multi-drop) Enter value between 0 to 99 129 Type of Host to be Communicated 0 Standalone 2 POS ECR 1 TMR ECR 130 Selection of Print Item on Prepack Total Label 0 Based on Status on Item Label 1 Based on Status on Manual Total Label 131 Print PLU Setting Quantity in Manual Mode 0 No 1 Yes 132 133 134
135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 nd
2
Receipt Total Report 0 No 1 Yes Change All PLU Default Format when Default SPEC Change 0 Yes 1 No Host Communication 0 No Operation 1 Enable Host Communication 0 RS-232C 1 RS-485 Port Number Enter value from range 1 to 254 One or Two Touch for Self-service Operation 0 One Touch 1 Two Touches Centering of Ingredient Data 0 Yes 1 No Permanent Price or Discount Price Change via Function Key 0 No Update to PLU 1 Update to PLU Number of Digits for Teraoka Code 0 2 Digits 1 3 Digits AA Message Size 0 24 x 24 1 16 x 16 Year Format 0 YY 1 YYYY Selection of Day Display for Sell by Date 0 Disable 1 Enable Peel Sensor Trigger Voltage 0 High 1 Low Display Prepack Quantity Balance 0 Enable 1 Disable Print Select Function Across the Board 0 Disable 1 Enable Label Format 1, 2 Function Key Enable 0 Inhibit 1 Allow Prepack Non-add Function Key Enable 0 Inhibit 1 Allow FIS3000 Code 0 SM-80/90 FIS3D 1 SM-25 FIS3D Main Group Function Key Enable 0 Inhibit 1 Allow Preset Key Assignment for Client 0 Local Assign 1 Central Assign Change Sell by Date or Used by Date when Packed Date Changed 0 No 1 Yes Sell by Date or Sell by Time for Individual PLU 0 Disable 1 Enable User Programmable Right Side Data for Item Barcode 0 With Identification Digit 1 Without Identification Digit Keysheet Letter Size 0 Small Letter 1 Capital Letter Test Print on Receipt 0 No Print 1 Print Image Copy from Free Format 0 Disable 1 Enable Training Mode 0 Disable 1 Enable FSD Price and Image 0 Disable 1 Enable ½ and ¼ Key Function 0 Disable 1 Enable Twisted Pair Cable for Ethernet
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.
26 December, 2006 8 For IR only.
8 For IR only. Use with SPEC128.
9 9 Effective when SPEC98 = 0.
8 For DM only. 9 8
9 9 9 9 8 8 For AA only.
9 9 8 8 9 9 Exclude AA. Exclude AA.
8
Exclude AA.
9 8 For FL & AS only.
8 For SD only.
9 8 Exclude DEC.
8 For U1 only.
8 8 8 of 32
Specification List SM-100 V2.00 0 Shield 1 Unshielded 161 Discount Label Format 0 Enable 1 Disable 162 Item Code Function Key Enable 0 Enable 1 Disable 163 Transaction Data Store in Client Memory 0 Disable 1 Enable 164 Maximum Label Length 0 120 mm 1 240 mm 165 Update Report for Client / Server System 0 Yes 1 No 166 Average Price and Weight Label Function 0 Disable 1 Enable 167 Label Date Title Print 0 No Print 1 Print 168 GB Code 0 GB Code 1 Shift GB Code 169 Print PLU Setting Unit in Manual Mode 0 No 1 Yes 170 User Specification (REZERO + 141) Accessible from Z Mode Only 0 No 1 Yes 171 Euro Mode 0 Disable 1 Enable 172 Dual Declarations 0 No 1 Yes 173 Mask 7-segment Display in X, S and Z Mode 0 No 1 Yes 174 175 176 177 178 179 180 181 182 183
184
9 9 Exclude AA.
8 For CN and MS only.
8 9 9 For U1 only.
8 For double display types only.
8 1
Print
Print $ and Weight Unit on Label 0 No Print
1
Print
Clear Total Data by Server 0 Both Server and Client
1
Server
For bench type only.
8 For UK only.
9 8 9 9
9 9 8
Effective when SPEC158 = 1.
9
188
Tare Decimal Point Left Shift for SM-25 FIS3D 0 No 1 Yes
189
PLU Auto Delete 0 No Delete 1 15 Days
2 3
30 Days 90 Days
Swap Weight and Unit Price on Receipt 0 No
1
Yes
nd
8
Duplicate Unit and Total Price on Label 0 No Print
186
2
For SD only.
8
Weigh PLU Can Use for Non-weigh PLU and Vice Versa Function Key Enable 0 Disable 1 Enable
190
8
Fixed Clerk Assign to Preset Key 8, 16, 24 and 32 0 Clerk Keys 1 Function Keys 30 lb to 15 kg Conversion 0 Disable 1 Enable Discount Time on Daily Basis 0 No 1 Yes Weight Check Function 0 No 1 Yes Unit Price Override per PLU 0 No 1 Yes Black Bar Sensing Label 0 Normal 1 Black Bar Sensing Scroll Message Group 0 Disable 1 Enable Continuos Label 0 Disable 1 Enable Character Size for Barcode Data 0 Large 1 Small PLU Clear after 10 seconds Time-out 0 No 1 Yes
185
187
26 December, 2006 Not in used.
8
8
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.
9 of 32
Specification List 191 192
193 194
195 196 197
198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217
218 nd
2
SM-100 V2.00
26 December, 2006 9
Default Item Code Equals to PLU Number 0 No 1
Yes
Nutrition Template 0 Standard 1 Simplified 2 Simplified Condensed
Standard Condensed Tabulated Tabulated Extra Condensed
8 3 4 5
For U1 and CA only.
Nutrition Adjustment Feed Enter value from range 0 to 255
9
Server IP Address Enter a value between 1 to 254
9
Weight Print for Non-weigh Item 0 No 1 Yes Scale File 0 Disable 1 Enable Print Format of Month 0 Number 2 3 Alphabetic 1 2 Alphabetic FSD Saving Calculation 0 Net Value 1 Cent Off FIS3000 Time Out 0 2 sec 2 32 sec 1 8 sec PLU Call Up Range 0 Disable 1 Enable Sell by Date for Manual Mode 0 Programmed Sell by Date 1 Zero Sell by Date Printing of Item Label when Barcode Data Overflow 0 Print 1 No Print Preset Keys Pages 0 1 Page 2 3 Pages by Shift Key 1 3 Pages by Toggle Reference PLU Function Key Enable 0 Inhibit 1 Allow Print Function Key Enable 0 Inhibit 1 Allow Print Barcode when Right Side Data Overflow 0 No print 1 Print Barcode Digits Weight Decimal Point Position for Barcode and Label Printing 0 Same as SPEC607 1 0.000
9
Network Time Out 0 3 sec 1 x2 FSD Calculation 0 Unit Price
9
For U1 and CA only.
For Client scale only.
2 3
x4 x10
1
Price Percentage Off
9
8 For U1 only.
8
9 9
8
8 Effective when SPEC607 = 2.
8
PLU Repeat Function Key Enable 0 Inhibit 1 Allow Pick ‘N’ Pay Protocol 0 Old 1 New Department Number for Pick ‘N’ Pay Enter a value between 1 to 99 Flag Code Function Key Enable 0 Inhibit 1 Allow DHCP Function 0 Disable 1 Enable Centering of Special Message 0 Yes 1 No JIS Code Table 0 New 1 Old Default Label Format 2 for Item Printing 0 Not Used 5 F5 1 F1 6 F6 2 F2 7 F7 3 F3 8 F8 4 F4 Zero Unit Price for Unit Price Change Function Key
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.
For U1 only.
8 For SF only.
8 For SF only.
9 8 For AA only.
10 of 32
Specification List SM-100 V2.00 0 Inhibit 1 Allow 219 Numeric Key Entry Reset 0 3 sec 2 Disable 1 5 sec 220 Item Barcode Right Side Data Dependent on Unit 0 Disable 1 Enable 221 222 223 224 225 226 227 228 229 230 231 232 233
nd
2
26 December, 2006 9 For AA only.
8 Effective when SPEC1 = 0 or 2.
Receipt with Tax Information Function Key Enable 0 Inhibit 1 Allow Open Cash Drawer without Sales Function Key Enable 0 Inhibit 1 Allow Negative Unit Price Function 0 Disable 1 Enable FIS3000 Wire Type 0 4 wires 1 2 wires Prepack Grand Total for Individual PLU 0 Yes 1 No Reverse Calculation of ITF Check Digit 0 No 1 Yes Unit Price Override Password Function 0 Inhibit 1 Allow
8
Individual PLU Total Transaction 0 No Preset Key Group 0 Disable
9 1
Yes
1
Enable
Auto Print after PLU Call 0 No 1 Yes Zero Unit Price for PLU and Unit Price Override 0 Inhibit 1 Allow Feed for Continuous Label 0 No 1 Yes Time Format 0 24 Hours 1 12 Hours (AM/PM)
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.
9 8 8
9
Effective when SPEC178 = 1.
Effective when SPEC150 = 1.
9 9 9 9
11 of 32
Specification List
SPEC NO. 234
SM-100 V2.00
26 December, 2006
SPECIFICATION DESCRIPTION Sub-total and Grand Total Barcode 0 Based on Item Barcode
SM-100 9
1
Based on Total Barcode
235
Mask Barcode Last Human Readable Check Digit 0 No 1 Yes
9
236
Character Generator for Korea 0 Old
8 1
New
Half-key Function 0 Inhibit
1
Allow
2
SM-25 Dots
237 238
239 240 241 242 243 244
FIS3000 Free Format Unit 0 mm 1 Dots
For KE only.
9
9
Cheque and Credit Payment Function Key 0 Inhibit 1
Allow
Voucher Payment Function Key 0 Inhibit
1
Allow
PLU Code for IR POS and TMR 0 6 Digits
1
7 Digits
Discount without Limit Function Key 0 Inhibit
1
Allow
Concatenate Commodity Name Display 0 No
1
Yes
Enable PLU Price Change Flag 0 No
1
Yes
8
245
Print Sell by Date or Used by Date when Date Equals Packed Date 0 Yes 1 No
9
246
Print First and Check Digits Outside Barcode 0 No 1
9 Yes
Print Packed date 0 Manual and Prepack Mode 1 Manual
2 3
Prepack Mode No Print
Print Sell by Date 0 Manual and Prepack Mode 1 Manual Mode
2 3
Prepack Mode No Print
Print Used by Date 0 Manual and Prepack Mode 1 Manual Mode
2 3
Prepack Mode No Print
Centering Shop Name on Label 0 No
1
Yes
Shop Name on Receipt 0 Top
1
Bottom
Auto Reconnect when Server Down 0 Disable 1 Every 2 min
2 3
Every 3 min Every 15 min
247
248
249
250 251 252
nd
2
9
9
9
9
9
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.
12 of 32
Specification List
SPEC NO. 253
254 255
256 257 258 259 260 261 262
263 264 265 266
267 268
269
270
271
nd
2
SM-100 V2.00
26 December, 2006
SPECIFICATION DESCRIPTION Client Auto PLU Update 0 Update / Delete Existing PLU 1 Update / Delete All Sever PLU 2 Update Existing PLU
3 4
Update All Server PLU Disable
Auto Update of Client Off-line Report 0 Disable
1
Enable
Retry Ethernet Communication 0 2 times
1
5 times
SM-100
Display Price with Tax after Clerk Key Press 0 Yes 1
No
For AA only.
Change Place Name to PLU via Function Key 0 No 1
Yes
For AA only.
Beef Labeling 0 No
1
Yes
Auto Print Sub-total Label in Prepack 0 No
1
Yes
Beef Labeling : Print Country 0 Code
1
Name
External Rewinder 0 Disable
1
Enable
Selection of Receipt / Label 0 Label
1
Receipt
FSD Net Value Minimum 0 Off
1
On
Print Ingredient Data on Next Label 0 Disable
1
Enable
Client Using Local Free Format Label 0 No
1
Yes
2
Exact Weight
1
Second Language
FSD Weight 0 Back Computed (Single Range) 1 Back Computed (Dual Range) CPDL Language Selection 0 First Language
8
9
9
9
8
8
8 For U1 only.
8
Exclude AA, HK, CN, TW and KE.
9 4 5 6 7
Individual Report Print and Clear in Z Mode 0 Disable 2 1 Manual Clear Store Total Report Clear 0 Store Total Report Only
For U1 only.
9
Display Special Scale Message for Discounted Item 0 No 1 Yes Auto Clerk Accumulation (for scanner) 0 No 1 V1 2 V2 3 V3
Always set to 1 for SM200.
1
V4 V5 V6 V7
For IR only.
Auto Clear
All Report
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.
Effective when SPEC270 = 1 or 2.
13 of 32
Specification List
SPEC NO. 272 273 274 275
276 277
278
279 280 281 282 283 284 285 286 287 288 289 290
nd
2
SM-100 V2.00
26 December, 2006
SPECIFICATION DESCRIPTION 9
Beef Reference Number 0 Code
1
Date
Item Code Follow PLU Number 0 Yes
1
No
Bench Key Pad 0 New
1
Old
Taiwan Receipt Printer 0 Disable
1
Enable
Floating Server 0 Disable
1
Enable
Real Time Buffer 0 No 1 2 Days 2 3 Days 3 4 Days
4 5 6 7
5 Days 6 Days 7 Days Unlimited
3 4
By Date and Reference No. By Date and PLU No.
U1 Self-service 0 Disable
1
Enable
Real Time Customer Number 0 No
1
Yes
Real Time Buffer Receipt 0 Detail
1
Total Only
Barcode Function 0 Without CR
1
With CR
Barcode Look-up-table (LUT) Contents 0 Non-weigh Item Only
1
All Items
Open Cash Drawer on Credit Payment 0 Allow
1
Inhibit
Australia ECR Function 0 No
1
Yes
Enforce Amount Tendered 0 No
1
Yes
Enforce Change Key 0 No
1
Yes
Planned Price Printed in Report 0 Enable
1
Disable
Repeat PLU Call 0 No
1
Yes
Payment Key 0 Disable
1
Enable
Traceability Report 0 Disable 1 By Reference No. 2 By PLU No.
SM-100
9
8
8 For TW only. Apply for POS1 FLEX PP2000 srs. 2 only.
9
9
8 For U1 only.
8 8
8
9
8 For AR only.
9
9
8
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.
For DEC countries only.
14 of 32
Specification List
SM-100 V2.00
SPEC NO. 291 292 293
294 295 296 297 298 299
300
301
SPECIFICATION DESCRIPTION
1
No Change
SM-200 Power Save 0 Back Light Off
1
Power Off
2 3
10 Min 2 Min
4 5 6
1 Min 2 Min 5 Min
SM-200 Battery Option 0 Yes
1
No
SM-300 Scrolling Message Update Rate 0 6 Lines
1
12 Lines
Ingredient File-Size Expansion 0 Maximum 99 records
1
Maximum 255 records
Print PLU Ingredient in Receipt 0 No
1
Yes
Traceability Update Function 0 No
1
Yes
2
80 Preset Keys
SM-500 Self-Service 0 No
1
Yes
Print Receipt after Accumulation 0 Yes
1
No
1
Enable
SM-200 Power Save Timeout 0 3 Min 1 5 Min PLU Scrolling Message Display Interval 0 Disable 1 3S 2 10S 3 30S
Keyboard Selection 0 Normal Keyboard # 1 100 Preset Keys
Fixed Port Number for Ethernet Enter value from 1 to 254
303
DHCP IP Address Lease Time 0 Disable
8
8
9
8
8
8
1
Enable
Unit Print on Receipt 0 Pcs
1
Items
Code Page 0 DOS
1
ANSI
SM-500 2 Receipt Printer 0 Disable
1
Enable
Praxis Function 0 Disable
1
Enable
nd
96 Preset Keyboard. Identical to SPEC688.
9
Character Spreading Speed Up 0 Disable
2
# 32/56 Preset Keys. Identical to SPEC672.
8
305
309
For SF only.
8
Server Port Number Enter value from 1 to 254
308
For U1 only.
8
304
307
SM-100 9
Gap Value In-feed Operation 0 Re-adjustable
302
306
26 December, 2006
8 (S3, S4, M3 & M4) For U1 only.
8
nd
For IR only.
8
8
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.
For DEC countries only.
15 of 32
Specification List
SPEC NO. 310
311 312 313 314
315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330
nd
2
SM-100 V2.00
26 December, 2006
SPECIFICATION DESCRIPTION Multi Barcode Type 0 EAN128 1 RSS
9 2
CODE128
Operator Logging Function 0 Disable
1
Enable
Price Change Password 0 Disable
1
Enable
Price Change Log File 0 Disable
1
Enable
2
Enable (Clerk Report)
1
No
Training Mode 0 Disable 1 Enable Print PLU Traceability in Receipt 0 Yes
SM-100
For AI 01 only.
9 For CA only.
9 For CA only.
8 For DEC only.
8
Include Prepack Total in Manual Total Report 0 Yes 1
No
Wireless Communication 0 No
Yes
9
9 1
Wireless FTP Port Number Enter value range from 1 to 9999
Not in used.
9
Delete Traceability Record 0 Yes
1
No
PLU Link to Text Field 0 Disable
1
Enable
Julian Date for Packed and Sell Date 0 No
1
Yes
Price Printing Size (Large Font) 0 No
1
Yes
Auto PLU Broadcasting 0 Disable
1
Enable
8
Decimal Point For Unit Price And Total Price 0 Disable 1
Enable
Peel Sensor Value 0 Re-adjust
1
No Change
ON/Off Key 0 Enable
1
Disable
SM300 Print Control 0
1
Enable
TU 9 Digit Total Price 0 Disable
1
Enable
PLU Tare Call up 0 Allow
1
Inhibit
Individual Scale Store Total Report 0 No
1
Yes
For U1 only.
8
9
8
8 For Tu only.
8 8
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.
16 of 32
Specification List
SPEC NO. 331 332
SM-100 V2.00
SPECIFICATION DESCRIPTION
1
Enable
ITEM Text (5-16) Print on Total Label 0 Disable
1
Enable
9
Image at Top Receipt Enter range from 0 to 99
334
Image at Bottom Receipt Enter range from 0 to 99
335
Traceability Eat By Date 0 Disable
1
Enable
Traceability Max Weight 0 Disable
1
Enable
5 6 7 8
F5 F6 F7 F8
1
EAN128
337
338
Traceability Default Label Format 0 Not Used 1 F1 2 F2 3 F3 4 F4 Traceability Barcode 0 EAN13
339
Flag Data (EAN13) Enter range from 0 to 99
340
Enforce Scan 0 No
1
Yes
TVP2000 (SM300) 0 Not Send T10
1
Send T10 Label Format
LCD 1 Line Scroll 0 Disable
1
Enable
Clear Key in Prepack 0 Enable
1
Disable
Print Pack Date 0 Yes
1
No
Update Spec For Server/Client System 0 Enable
1
Disable
341 342 343 344 345 346
347 348 349
nd
2
SM-100 9
Default ITF for Barcode 0 Disable
333
336
26 December, 2006
Update Label Turn-over In Receipt Buffer 0 No 2 1 Only In Registration Mode 3
Only In Prepack Mode Both
Internet Broadcast 0 No
1
Yes
Taiwan POP Label 0 Disable
1
Enable
Direct Access To Clerk Mode 0 Disable
1
Enable
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.
For TW only
20 of 32
Specification List
SPEC NO. 350 351
nd
2
SM-100 V2.00
SPECIFICATION DESCRIPTION Additional Rounding In Receipt 0 Print
1
No Print
Gratuitous ARP 0 Disable
1
Enable
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.
26 December, 2006
SM-100
21 of 32
Specification List
SPEC NO. 400
401
SM-100 V2.00
26 December, 2006
SPECIFICATION DESCRIPTION
SM-100 9
Auto Power-Off Function 0 Inhibit 1 3 Minutes 2 10 Minutes
3 4 5
30 Minutes 1 Hour 3 Hours
RTS/CTS Handshaking of RS-232C 0 On
1
Off
9
402
Reset Receipt consecutive Number after Reset Report 0 No 1 Yes
9
403
Vender Number Display in Registration Mode 0 Allow 1 Inhibit
9
404
Number of Vender Keys 0 4 Vender Keys 1 5 Vender Keys
9 2 3
6 Vender Keys 7 Vender Keys
405
Priority of Shop Name and Special Message on Receipt 0 Shop Name Priority 1 Special Message Priority
9
406
Centering of shop name on Receipt 0 Allow
9
407
1
Inhibit
Centering of special Message on Receipt 0 Allow 1
Inhibit
9
408
One or Two Touch for Receipt Printing in AMT/TEND 0 One Touch 1 Two Touch
9
409
PLU Number Printing on Receipt 0 Inhibit
9 1
Allow
Sale Item Entry Method 0 Total
1
Item
410 411 412 413 414
415 416 417
nd
2
9
Default Vender Transaction by Print Key 0 Allow 1
Inhibit
Print Checking Line 0 Print
1
No Print
Source of Used by Date 0 Current Date
1
Packed Date
9
9 9
In-Store Barcode for Barcode Scanner Enter 0 F1F2 CCCCCC TTTT CD 5 1 F1F2 CCCCC TTTTT CD 6 2 F1F2 CCCC TTTTTT CD 7 3 F1F2 CCC TTTTTTT CD 8 4 F1F2 CC TTTTTTTT CD
9 F1F2 CCCCC XCD TTTT CD F1F2 CCCC XCD TTTTT CD F1F2 CCCCC PCD TTTT CD F1F2 CCCCC 0 TTTT CD
#1: F1F2 - 20~29 #2: CC ~ CCCCCC Item code. #3: TTTT ~ TTTTTTTT Total Price
9
Non-PLU Item Enter by Barcode Scanner 0 Allow 1
Inhibit
Barcode Scanner 0 Allow
1
Inhibit
Centering of Commodity Name on Label 0 Allow 1
Inhibit
9 9
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.
22 of 32
Specification List
SPEC NO. 418 419 420 421
SM-100 V2.00
26 December, 2006
SPECIFICATION DESCRIPTION 9
Weight Data Synchronization Function 0 Allow
1
Inhibit
Open Cash Drawer when Issue Label 0 Allow
1
Inhibit
Print Grand Total on Sales Report 0 Allow
1
Inhibit
2
Receipt Data & Label Data
Constitution of Report 0 Receipt Data 1 Label Data
SM-100
9
9
9
422
Currency Symbol for Total Amount on Receipt 0 No Print 2 Suffixation 1 Prefixion
9
423
Print Total Number of Pieces on Receipt 0 Allow 1
9
424 425
426
Inhibit nd
Total Barcode on Receipt for Total Price in 2 0 Allow 1
Currency Inhibit
Second Currency as Reference Price 0 No 1 For Receipt
2 3
For Label For Receipt and Label
Print Tare Weight when Unit Price is 0 0 Allow
1
Inhibit
9 For FR only.
9
9
427
Eliminate Cash Line on Receipt when No change Operation 0 Allow 1 Inhibit
9
428
PRINT Tax List on Receipt 0 Allow
9 1
Inhibit
Non-Weigh PLU Unit Price Display 0 Total Price Column
1
Unit Price Column
429
Effective when SPEC603 =1
9
430
Items on PLU / Main Group / Dept / Tax Report 0 Registered Items 1 All Items
9
431
Eliminate Vender Data on Sales Report 0 Allow
9
432
1
Font Size for Commodity Name on Receipt 0 Standard Font Size 2 1 Larger Font Size
Inhibit 9 Largest Font Size
433
Condition of Additional Price Rounding for Total Price 0 Cash Payment Only 1 Always
9
434
Item Barcode Type 0 EAN Type 1 ITF Type
9
435
Total Barcode Type 0 EAN Type
2
User Programmable
1
ITF Type
9
436
In-Store Barcode Type for Barcode Scanner Enter 0 EAN Type 1 ITF Type
9
437
Print Rounding on Receipt 0 Allow
9
nd
2
1
Inhibit
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.
23 of 32
Specification List
SPEC NO. 438 439
440
SM-100 V2.00
26 December, 2006
SPECIFICATION DESCRIPTION 9
Print Sub-Total on Receipt 0 Allow
1
Inhibit
Pulse width for Opening Cash Drawer 0 20ms (Default Value) 1 50ms 2 100ms
3 4 5
200ms 300ms 400ms
2
Power On & Password R Key
R Mode Password Function 0 Inhibit 1 Password R Key
SM-100
9
9
441
Set / Reset Auto PLU Call Function Key Enable 0 Allow 1 Inhibit
9
442
Change Main Group Code for Auto Plu Call Function Key Enable 0 Allow 1 Inhibit
9
443
Prefix Fixed Code to PLU Code for Auto PLU Calling 0 No 2 2 Digits 1 1 Digit 3 3 Digits
9
Decimal Point Position for Second Currency 0 None 2 1 0.0 3
9
444
0.00 0.000
445
Unit Price Change for PLU after Label Printing 0 Inhibit 1 Allow
446
Print Tare Weight on Receipt 0 Allow
447 448 449 450 451
452 453
nd
2
Effective when Spec39 = 1, Spec40 = 0
1
Inhibit
Place Change for PLU after Label Printing 0 Inhibit 1
Allow
9
9
Sell Date Change for PLU after Label Printing 0 Inhibit 1 Allow
For KE only.
9 For KE only.
Trace Auto Clear 0 Inhibit
1
Allow
For KE only.
Trace per PLU 0 Inhibit
1
Allow
For KE only.
Trace Auto Update 0 Inhibit
1
Allow
For KE only. Effective when Spec450 = 1.
Trace Confirm 0 Inhibit
1
Allow
For KE only.
Trace C/D Check 0 Inhibit
1
Allow
For KE only.
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.
24 of 32
Specification List SPEC NO. 454 455
456 457 458 459 460
461 462
463
nd
2
SM-100 V2.00
26 December, 2006
SPECIFICATION DESCRIPTION Forced Tare when Tare Value in PLU is 9999 0 Inhibit 1 Printing of Servings Fact 0 SS Top & SC Bottom 1 SS Bottom & SC Top Special ‘FOR’ operation 0 Inhibit
SM-100 9
Allow
For CA only.
9 2 3
SS Print Only SC Print only
1
Allow
CN Weight Trace function 0 Inhibit
1
Allow
CN Weight Quota function 0 Inhibit
1
Allow
Symbol Format for Date Print 0 Dash
1
Period
CN Weight Trace Password 0 Inhibit
1
Allow
For CA only.
9 For U1 only.
9 For CN only.
9 For CN only.
9
9 For CN only.
Unit and Currency Symbol for each line in Receipt 0 Inhibit 1 Allow
9
1000 Separator for total line print on receipt 0 Inhibit 1
9 Allow
Print SHAMSI date 0 Inhibit
Allow
For U1 only.
For IN only.
9 1
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.
For IN only.
25 of 32
Specification List
SM-100 V2.00
26 December, 2006
[REZERO] + [1][4][2] WEIGHT AND MEASUREMENT SPECIFICATION (Span Switch must be ENABLE when accessing this mode.) SPEC NO.
SPECIFICATION DESCRIPTION
SM-100
600
Price Base for Price Calculation for Weighed Items 0 100 g Base 2 1 lb Base 1 1 kg Base
9
601
Auto Zero Function 0 Enable
9 1
Disable
Display Type 0 Single Display
1
Three Display
Tax 0 No Tax
1
Tax
Minus Weight Masking 0 Minus Gross > 9e
1
Minus Gross Weight Mask
Manual Scale Start 0 Auto Start
1
Manual Start
Zero Lamp Lighting Position 0 Gross Zero +/- ¼d
1
Net Zero +/- ¼d
Decimal Point Position for Weight 0 None 1 0.0
2 3
0.00 0.000
602 603 604 605 606 607
8
9 9
8 8
9
608
Zero Point Setting Range when A/C Display Switch On 0 +/- 10% of Capacity 2 +/- 3% of Capacity 1 +/- 5% of Capacity 3 +/- 2% of Capacity
9
609
Decimal Point for Unit Price and Total Price 0 None 2 1 0.0 3
9 0.00 0.000
Unit Price Decimal Right Shift 0 Inhibit
1
Allow
Unit Price Decimal Left Shift 0 Inhibit
1
Allow
2
500 g / 1 kg
610 611 612
Switching of Price Base 0 Inhibit 1 100 g / 1 kg
8 8
9
613
Exit from Accumulation Mode after within Specified Interval 0 Inhibit 2 5 Sec 1 15 Sec 3 10 Sec
9
614
Zero Setting Range when Weight Reset Switch is On or Zero Tracking 0 +/- 10% of Capacity 2 +/- 2% of Capacity
8
(Power on Start Point +/- 6000 IR)
1
+/- 5% of Capacity
(Power on Start Point +/- 1200 IR)
3
(Power on Start Point +/- 3000 IR)
615
nd
2
Minimum Display 0 1 1 2
+/- 0.6% of Capacity (Power on Start Point +/- 360 IR)
9 2 3
5 10
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.
26 of 32
Specification List
SPEC NO. 616 617 618 619
620
621
622 623 624 625 626 627
SM-100 V2.00
26 December, 2006
SPECIFICATION DESCRIPTION Selection of Resolution 0 1/3000 1 1/6000 New A/D 0 No Weight Single Interval or Multi-Interval 0 Single Interval
SM-100 9
2
1/7500
1
Yes
1
Multi-Interval
8 9
PLU Weight Item Commodity Name Display 0 Full Display 2 1 Half Display
8 No Display
For EB and EP type.
9
Tare Accumulation 0 Allow
1
Inhibit
Tare Subtraction 0 Allow
1
Inhibit
Manual Clear of Tare 0 Allow
1
Inhibit
Weight Reset Operation during Tare 0 Allow
1
Inhibit
Zero Tracking during Tare 0 Allow
1
Inhibit
Accumulation when Tare 0 Allow
1
Inhibit
Digit Tare 0 Allow
1
Inhibit
Decimal Point Figure 0 Period
1
Comma
Effective when SPEC632 = 0.
9 Effective when SPEC632 = 0.
9
9
9 9
9
9
628
Price Rounding Method for Decimal Digits on Weighed Item 0 Rounding 2 Cut Up 1 Truncating
9
629
Additional Price Rounding Method for Item Price st 0 No Addition Rounding 4 Rounding for 1 Digit st 1 ¼ Rounding (25 step) 5 Truncate 1 Digit st 2 Special Rounding (5 step) 6 Cut Up 1 Digit 3 5 Floor Rounding (0~4: 0, 5~9: 5)
9
630
Selection of Auto Clear of Unit Price 0 Inhibit
9 1
Allow
Selection of Maximum Capacity 0 Capacity +1d
1
Capacity +9d
Selection of Tare Value Exchange 0 Allow
1
Inhibit
Auto Clear of Tare 0 Inhibit
1
Allow
631 632
633
nd
2
8
8 Related to SPEC620 and 621.
9
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.
27 of 32
Specification List
SPEC NO. 634
635 636 637
638
SM-100 V2.00
26 December, 2006
SPECIFICATION DESCRIPTION Auto Tare Clear when Rezero 0 Inhibit
SM-100 9
1
Trigger Point of Tare / Unit Price Auto Clear 0 Over Net 5d and Gross 21d and 1 Weight Stability Auto Zero Reset 0 Inhibit 1
Allow
Effective when SPEC623 = 0.
9 >= Net 1d and Price > 0 and Weight Stability
Effective when SPEC633 = 1.
8 Allow 8
Negative Weight Tare Clear 0 Allow
1
Inhibit
Tare Range 0 < 50% of Capacity 1 < 5% of Capacity
2 3
Maximum 200 g Not Used
Effective when SPEC622 = 0.
8
639
Exit From Accumulation Mode when Weight Change 0 Inhibit 1 Allow
9
640
Price Accumulation with Weight Change More than +/- 10d 0 Inhibit 1 Allow
9
641
Accumulation Available Only after Scale Shows Weight is Equal Zero 0 Inhibit 1 Allow
9
Tare Display for One Touch Tare 0 Allow
8 1
Inhibit
Weight Range for Non-weigh Item 0 Only Net 0d
1
Always
Weight Stability Condition 0 Loose 1 Normal
2 3
Tight Stringent
2
Over Net 19d and Weight Stability
3
Over Net 20d and Weight Stability
2
Over Net 19d and Weight Stability
3
Over Net 20d and Weight Stability
PLU Tare 0 Allow
1
Inhibit
Item Print when Tare 0 Allow
1
Inhibit
Tax Rounding Method 0 Rounding
1
Truncation
642 643 644
645
646
647 648 649 650 651
nd
2
Weight Range for R Mode Printing 0 Over Net 5d and Over Gross 21d and Weight Stability 1 Over Net 1d and Weight Stability Weight Range for Prepack 0 Over Net 5d and Over Gross 21d and Weight Stability 1 Over Net 1d and Weight Stability
Effective when SPEC640 = 0.
9 9
9
9
9
9 8
9
Checking Span Switch for Internal Count 0 No 1
Yes
Certain Function Key Order 0 Function Key Precede Numeric Key
Numeric Key Precede Function Key
8 1
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.
28 of 32
Specification List
SPEC NO. 652 653 654 655
656
657 658 659 660
SM-100 V2.00
26 December, 2006
SPECIFICATION DESCRIPTION 9
Angle Rotation for Certain Items Printing 0 Anti-clockwise 1
Clockwise
Total Price Discount 0 Allow
1
Inhibit
1
Allow
1
Inhibit
5 6 7 8
Cassette-B Cassette-P B-CS P-CS
Password Setting 0 Allow
1
Inhibit
Extra Label for Prepack Printing 0 Inhibit
1
Allow
Item Price Printing 0 Item Price before Tax
1
Item Price after Tax
Barcode Check Line 0 Print
1
No Print
Packed Date Function in Manual Mode 0 Inhibit Prepack Mode 0 Allow Scale Type 0 Pole 1 Bench 2 Elevated 3 Hanging 4 Self-service
SM-100
9
9 9 Always set to 1 for SM200.
9 Always set to 0 for SM200.
9 By-pass Span Switch.
8
8
9
661
Additional Price Rounding Method for Total Price st 0 No Addition Rounding 4 Rounding for 1 Digit st 1 ¼ Rounding (25 step) 5 Truncate 1 Digit st 2 Special Rounding (5 step) 6 Cut Up 1 Digit 3 5 Floor Rounding (0~4: 0, 5~9: 5)
9
662
Unit Price Recalculation 0 Inhibit
8 1
Allow
Nordic Country 0 Inhibit
1
Allow
Self-service Type 0 Inhibit
1
Allow
663 664
8
9 Related SPECs are 126, 136, 672.
665
Swap of Unit Price and Total Price Display in R Mode 0 Inhibit 1 Allow
8
666
Multiplication Operation in Prepack Mode 0 Inhibit 1
9
667
nd
2
Dot Matrix Display Scanning Rate 0 Normal 1 Slow R Mode Display Configuration 0 Standard 1 Without Tare Weight
Allow 8
2 3
High Very High
2 3
Not Used Not Used
8
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.
29 of 32
Specification List
SPEC NO. 668
669 670 671 672
673 674 675
676
677 678
679
SM-100 V2.00
26 December, 2006
SPECIFICATION DESCRIPTION 9
Commodity Name Display Interval 0 0.5 Sec 1 1.0 Sec
2 3
1.5 Sec # 2.0 Sec #
16 x 16 Commodity Name Display 0 1.0 Sec 1 1.5 Sec
2 3
2.0 Sec 2.5 Sec
Mask Weight Display 0 No
1
Yes
Scroll Message Display 0 Full Length
1
Half Length
1
Version 0.16 and Above
2
80 Preset Keys
Hanging Scale 0 No
1
Yes
Masking Last Digit Over 15 lb 0 No
1
Yes
Auto Zero Adjustment Range 0 +/- 5d
1
2% of Capacity
Display CPU Selection 0 Below Version 0.16 Keyboard Selection 0 Normal Keyboard # 1 100 Preset Keys
SM-100
For EB and EP type. # Effective when SPEC619 = 0.
8 For CN, HK, MS and TW.
8
8 For EB and EP type.
8 8 # 32/56 Preset Keys.
8 8
8 Effective when SPEC636 = 1.
Right Side Barcode Data Shifting for Item and Total Barcode 0 No 3 Left Shift Twice 1 Right Shift Once 4 Left Shift 3 Times 2 Right Shift Twice 5 Left Shift Once
9
Manual Weight Function Key 0 Disable
9 1
(left shift valid for quantity only)
Enable 8
Printing of Item Label after Weight Change 0 Inhibit 1
Allow
Catty (Kati) and Tael 0 Disable
Enable
For SS type. Effective when SPEC640 and 641 = 1.
8 1
680
Tare Clear when Exit From Z mode, Password Mode, Changing of Customer, and Weight and Measure Specification 0 No 1 Yes
681
Euro Second Price Rounding Method 0 Rounding 1 Truncating
Available in special version only.
8
9 2
Cut Up
682
Additional Euro Second Price Rounding Method st 0 No Addition Rounding 4 Rounding for 1 Digit st 1 ¼ Rounding (25 step) 5 Truncate 1 Digit st 2 Special Rounding (5 step) 6 Cut Up 1 Digit 3 5 Floor Rounding (0~4: 0, 5~9: 5)
9
683
Foreign Code for Standard Countries 0 Inhibit 1 GB Code
8
nd
2
2
Korean Code
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.
Not effective for AA, CN, HK, KE, MS and TW.
30 of 32
Specification List
SPEC NO. 684
685 686 687 688 689
690 691
SM-100 V2.00
SPECIFICATION DESCRIPTION Calibration at 1/5 of the Capacity 0 Disable
Enable
Auto Selection Between Two Label Format 0 Inhibit 1
Allow
Rounding for Weight 0 No
1
Yes
Proportional Tare 0 No
1
Yes
1
Yes
2 3
4 Sec Stop 6 Sec Stop
Test Program 0 Disable
1
Enable
One Touch Tare 0 Enable
1
Disable
SM-500 Self-service 0 No Consecutive Display 0 1 Sec Stop 1 2 Sec Stop
9 9
8 8
8
8 8
693
Flexi Self-Service Key Grouping 0 No
1
Yes
Weight Hold Function 0 Disable
1
Enable
Clerk Password Setting 0 Disable
1
Enable
Quantity Symbol Re-calculation 0 No
1
Yes
696
9 8
9
RESERVED
698
DEC PLU Tare 0 No
1
Yes
Right side Data of Barcode Shift 0 Normal 1 Quantity
2 3
Weight Price
nd
2
For CA only.
8
697
699
Not effective when SPEC615 = 0.
8
RESERVED
695
SM-100 8
1
692
694
26 December, 2006
8 8
9
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.
31 of 32
Specification List
SPEC NO. 700 701 702
SM-100 V2.00
26 December, 2006
SPECIFICATION DESCRIPTION
SM-100 9
Version Display When Power On 0 Allow
1
Inhibit
Re-Zero Function 0 Allow
1
Inhibit
Total Price Display 0 Allow
1
Inhibit
9
9
703
Tax Rounding Method for Tax Value Excluded in Price 0 Rounding 2 Cut Up 1 Truncation
9
704
Tax Rounding Method for Tax Value Included in Price 0 Rounding 2 Cut Up 1 Truncation
9
705
Commodity Name Display When Call PLU in Label Mode 0 Allow 1 Inhibit
9
706
Commodity Name Display When Call PLU in Receipt Mode 0 Allow 1 Inhibit
9
707
Price Fix 0 Inhibit 1 Allow
9 2
Via FIX Key
Tare Fix 0 Inhibit 1 Allow
2
Via FIX Key
708
9
709
Printing of Item Label Condition in Prepack Mode 0 Weight Change (More than +/-10e) 1 Remove Weight
9
710
Net / Gross Multi-interval 0 Gross Multi-interval
9 1
Net Multi-interval
Priority of Tare Operation 0 One Touch Tare Priority
1
Digit Tare Priority
Receipt mode 0 Allow
1
Inhibit
711
712
nd
2
9
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD.
32 of 32
SM-100 Flexible Barcode Setting Guide Operation
Display tare
weight
S1
-- -->
S46
-- -->
Unit price/kg
Remark
price
Press [mode] third PLU FILE
Enter programmer.
times Enter Press numeric 4 and 6
Flexible
Barcode
FLEXI BARCODE programme.
Press [*]
S46.0
F BAR
0
NO SET
Program Flexible Barcode.
Enter numeric 1
S46.0
F BAR
1
NO SET
Program Flexible Barcode 1. Program Flag Code.(0 for F2,1
Press [*]
S46.1
F BAR
0
FLAG
for F1F2,2 for non.)
Press [*]
S46.2
F BAR
0
ITEM CODE
Enter item code length. Enter data format for DATA1.( 0 for weight,1 for quantity,2 for unit
Press [*]
S46.3
F BAR
0
DATA1
price.3 for weight/quantity,4 for total price,5 for original price,6 for user programmable.)
Press [*]
S46.4
F BAR
0
DIGIT
Enter DATA1 length. Shift for DATA1.( 0 for no right shift,1 for right shift, 2 for right
Press [*]
S46.5
F BAR
0
SHIFT
shift x2, 3 for left shift, 4 for left shift x2, 5 for left shift x3.) Enter data format for DATA2.( 0 for weight,1 for quantity,2 for unit
Press [*]
S46.6
F BAR
0
DATA2
price.3 for weight/quantity,4 for total price,5 for original price,6 for user programmable.)
Operation
Press [*]
Display tare
weight
Unit price/kg
price
S46.7
F BAR
0
DIGIT
Remark
Enter DATA2 length.
Shift for DATA2.( 0 for no right shift,1 for right shift, 2 for right Press [*]
S46.8
F BAR
0
SHIFT
shift x2, 3 for left shift, 4 for left shift x2, 5 for left shift x3.) Press [ⅹ] to select the
Press [*]
S46.9
F BAR
NO MIDDLE CD
middle check digit. Press [ⅹ] to select the last
Press [*]
Press [*]
S46.1
S46.1
F BAR
F BAR
NO LAST CD
ITF BARCODE
check digit. Press [ⅹ] to swith ITF and EAN barcode.
Press [#]
S46
-- -->
FLEXI BARCODE
Save the flexible barcode 1.
Note: See the Flexible Barcode Usage Note at 《3.6.1 PLU programming》 in SM-100 Operation manual.
SM-100 Traceability Setting Guide Prepare ¾
Set SPEC258 to “1”
Traceability Programming Operation
Display Unit price/kg
price
Remark
tare
weight
[Mode] [Mode] [Mode]
S1
Æ
PLU FILE
[3] [4]
S34
Æ
COUNTRY FILE
[*] [1]
S34.0
[*][C][H][I][N][A]
S34.1
COUN
[#]
S34
Æ
COUNTRY FILE
Save Country No. 1
[3] [5]
S35
Æ
CUTTING HALL
Enter cutting hall programming
[*] [1]
S35.0
HALL
1
NO SET
[*][1]
S35.1
HALL
1
COUNTRY
Program cutting hall country No. 1
[*][C][U][T]
S35.2
HALL
CUT
Name 3
Program cutting hall name “CUT”
[#]
S35
Æ
Enter S mode
Enter country file programming
1
NO SET
Program country No. 1
CHINA
Name 5
Program country name “CHINA”
CUTTING HALL
Program cutting hall No. 1
Save cutting hall No. 1
Operation
Display tare
weight
Unit price/kg
price
S36
Æ
SLAUGHTER
HOUSE
Remark Enter
[3][6]
slaughter
house
programming
[*][1]
S36.0
HOUSE
1
NO SET
[*][1]
S36.1
HOUSE
1
COUNTRY
Program slaughter house No. 1
Program slaughter house country No.1 Program slaughter house name [*][S][L][A][U][G]
S36.2
HOUSE
SLAUG
NAME 5 “SLAUG”
[#]
S36
Æ
[4][7]
S47
Æ
[*][1]
S47.0
KIND
1
NO SET
Program kind file No. 1
[*][M][E][A][T]
S47.1
KIND
MEAT
NAME 4
Program kind name “MEAT”
[#]
S47
Æ
KIND FILE
[4][8]
S48
Æ
CATEGORY FILE
[*][1]
S48.0
CATEG
1
NO SET
Program category No. 1
[*][B][E][E][F]
S48.1
CATEG
BEEF
NAME 4
Program category name “BEEF”
[#]
S48
Æ
SLAUGHTER
HOUSE
Save slaughter house No. 1
KIND FLIE
Enter kind file programming
CATEGORY FILE
Save kind file No. 1
Enter category file programming
Save category file No. 1
Operation
Display Unit price/kg
Remark
tare
weight
price
[4][9]
S49
Æ
[*][1]
S49.0
BREED
1
NO SET
Program breed file No. 1
[*][B][U][L][L]
S49.1
BREED
BULL
NAME 4
Program breed name “BULL”
[#]
S49
Æ
BREED FILE
[3][7]
S37
Æ
TRACEABILITY
[*][1]
S37.0
TRACE
1
NO SET
Program traceability No. 1
[*][1]
S37.1
TRACE
1
BORN
Choose born country No. 1
[*][1]
S37.2
TRACE
1
FATTEN
Choose fatten country No. 1
[*][1]
S 37.3
TRACE
1
S HOUSE
Choose slaughter house No. 1
[*][1]
S37.4
S CNT
1
LNK 1
BREED FILE
Enter breed file programming
Save breed file No. 1
Enter traceability programming
Choose link country No. 1 for slaughter house
[*][1]
S37.5
TRACE
1
C HALL
[*][1]
S37.6
C CNT
1
LNK 1
Choose cutting house No. 1
Choose link country No. 1 for cutting hall
[*][1]
S37.7
TRACE
1
ORIGIN
Choose original country No. 1
Operation
Display
Remark
tare
weight
Unit price/kg
price
[*][R][C][D]
S37.8
R-CD
RCD
NAME 3
Program R-CD content “RCD”
[*][G][T][I][N]
S37.9
GTIN
GTIN
NAME 4
Program GTIN content “GTIN”
[*][L][O][T]
S37.10
LOT
LOT
NAME 3
Program LOT content “LOT”
[*][1]
S37.11
TRACE
1
KIND
[*][1]
S37.12
TRACE
1
CATEG
Choose category No. 1
[*][1]
S37.13
TRACE
1
BREED
Choose breed No. 1
[*][C][O][N][T]
S37.14
CONT
CONT
NAME 4
Program cont content “CONT”
[*][0][6][0][3][1][0]
S37.15
TRACE
060310
EAT D
Program eat by date “06/03/10”
[*][5][0][0][0]
S37.16
TRACE
5.000
WEGHT
Program maximum weight “5kg”
[*][S][C][D]
S37.17
S CD
SCD
NAME 3
Program S CD content “SCD”
[*][S][N][M]
S37.18
S NM
SNM
NAME 3
Program S NM content “SNM”
[*][S][A][D][1]
S37.19
S AD1
SAD1
NAME 4
Program S AD1 content “SAD1”
[*][S][A][D][2]
S37.20
S AD2
SAD2
NAME 4
Program S AD2 content “SAD2”
[#]
S37
Æ
TRACEABILITY
Choose kind No. 1
Save traceability No. 1
Free Format Programming ¾ ¾
Enter “S12 Æ FREE FORMAT”, press [*] Edit the correlative items for traceability in free format
PLU ITEM Programming ¾ ¾
Enter “S19 Æ PLU ITEM”, press [*] Set “ Item TRACE” to “PROGRAM” and press [#] to save
PLU Programming ¾ ¾ ¾
When you edit PLU, set “S1.64 PLU” to “TRACE ALLOW” and press [*] Input traceability number and press [#] to save In the end, when you call the PLU and print label, you’ll see the traceability information on the label
SM-100 Nutrition Fact Setting Guide Concept Nutrition uses fix template to print. Totally It has 12 fix templates(No. 70 ~ No. 81).
Setting Method 1. 2. 3. 4. 5. 6.
7. 8. 9. 10. 11. 12.
Enter S mode Enter “S19 --- PLU ITEM” and set “IMAGE” and “NUTRI” to “PROGRAM” Enter “S12 --- FREE FORMAT” Enter “S12.5 IMG 1 Å 47 F ITEM” to “S12.5 IMG 10 Å 56 F ITEM” to set the print area of Nutrition. (In each label format, totally you can print 10 images) Enter “S1 --- PLU FILE” to create PLU. Enter “S1.50 PLU 0 IMAGE 1” to choose the template number for IMAGE 1 (From No. 70~ No. 81). … Enter “S1.59 PLU 0 IMAGE 10” to choose the template number for IMAGE 10 (From No. 70~ NO. 81). Set “S1.81 PLU PRINT NUTRI” to set nutrition print status to “Print”. Enter from S1.82 to S1.10 to input nutrition contents. For extra details on the Nutrition Fact, Enter S11: TXT form to edit by hands. Enter “S12 --- FREE FORMAT” to set up the TXT position. Press [PLU] key to save.
PCFL-1 Operation Guide Shanghai TERAOKA Electronic Co., Ltd. --- Technical Support Dept.
8
Tel: +86-21-6408-5151 Fax: +86-21-6408-3468 E-Mail:
[email protected]
Note: this guide is available just for SM series expect the SM-100. 一、 The link of the hardware Link the PC with scale via RS232C.
二、 Operation 1. The Spec setting in the scale 3 for SPEC51
(The SIO baud rate is 9600. )
1 for SPEC52
(The SIO data length is 8.)
0 for SPEC53
(No SIO parity digit.)
0 for SPEC54
(1 bit stop bit.)
2 for SPEC60
(SIO work via PCFL-1)
2. The setting in the software 1) open the software
PCFL-1 Operation Guide Shanghai TERAOKA Electronic Co., Ltd. --- Technical Support Dept.
8
Tel: +86-21-6408-5151 Fax: +86-21-6408-3468 E-Mail:
[email protected]
2) the com port setting
Please note: a) The com port should be the same as the one used in your computer. b) The com port setting must be same as setting in the scale. 3) the folder for save
PCFL-1 Operation Guide Shanghai TERAOKA Electronic Co., Ltd. --- Technical Support Dept.
8
Tel: +86-21-6408-5151 Fax: +86-21-6408-3468 E-Mail:
[email protected]
Note: You could set the default folder for save the data received from the scale. 3. Operation 1) receive the data from the scale
PCFL-1 Operation Guide Shanghai TERAOKA Electronic Co., Ltd. --- Technical Support Dept.
8
Tel: +86-21-6408-5151 Fax: +86-21-6408-3468 E-Mail:
[email protected]
Note: You could press the key to receive the data from scale. 2) send the data to scale
Note: You could press the key to send the data to scale. 2) the operation in the scale Display
Remark
Operation Weight Unit price
Price
Z
[M][0][M][M]
DAILY
0
CLR
X
Enter the [Z] mode
[zero]+[0][1][0]
BAC
PLU
FILE
X
Press preset key [7]or [8] to select
Preset key [8]
BAC
FOR
FILE
X
the transmit item: PLU, Format,
Preset key [8]
BAC
OTH
FILE
X
Others or All.
Preset key [8]
BAC
ALL
FILE
X
PCFL-1 Operation Guide Shanghai TERAOKA Electronic Co., Ltd. --- Technical Support Dept. Tel: +86-21-6408-5151 Fax: +86-21-6408-3468 E-Mail:
[email protected]
[*]
BAC
SA TO
FL-1
X
Press preset key [7]or [8] to select the transmit method: save data to
Preset key [8]
BAC
RD FR
FL-1
X
Preset key [8]
BAC
COMP
FL-1
X
data with FL-1.
[*]
T-OUT
OPN
GOOD
X
Transmit successfully.
[Tare]
DAILY
0
CLR
X
Back to Z mode.
Jasonzhou, Shanghai Teraoka Electronic Co.,Ltd Technical Service Dept. th
Dec. 7 ,2005
FL-1,read data from FL-1,verify
SM100
ERROR MESSAGE
9. SM100 ERROR MESSAGE ERROR MESSAGE The machine beeps and following error messages appear on display, if incorrect operation is performed. No.
Error Message
Causes Label sensor sense no label. No more labels. Replace
1
PAPER END
2
FEED PAPER FIRST
Label miss feed, press FEED key to align label.
3
PEEL LABEL
Peel sensor activated, remove label away from sensor.
4
CHANGE PAPER
Change paper mode between label and receipt.
6
NON PRINT
No manual printing.
7
UNIT PRICE OVERFLOW
Please check unit price.
9
NON LABEL
12
MEMO NOT INITIALIZED
Memory problem. Please clear the memory.
14
HEAD IS NOT CLOSED
Thermal head no closed. Please close thermal head.
16
FILE MEMORY FULL
18
PLEASE REMOVE WEIGHT
Fixed price item, please remove weigh.
19
PLU NOT EXIST
No such PLU data or number exists.
20
TOTAL PRICE IS 0
24
WEIGHT OF
Weight over maximum capacity when print.
26
TOTAL PRICE OVERFLOW
Total price over the limit to display or print.
29
PLEASE SET TARE VALUE
When force tare is enable, a tare weight must be entered.
39
PLEASE PRESS PLU KEY
Press PLU(#) key. To save data in some procedure.
44
KEY ALREADY ASSIGNED
Preset key already been assigned with function or PLU.
48
PLU DATA INVALID
U1 only. Quantity setting incorrect when using FOR.
49
QTY OF
Quantity data over the limit.
54
BELOW MIN WEIGHT
Weight is below min weight set when printing.
57
PRICE ACC OF
Accumulated quantity over the limit.
59
PLEASE SEE LABEL QTY
Set print label quantity when the function is use.
61
GRAND TOTAL OF
Grand total price over the limit.
71
PRINT INHIBITED
Cannot print weigh item at Prepack mode.
74
SELF SERVICE MODE
Can only use Self-service procedure only.
95
CAL00 ERROR
Zero point calibration error.
96
CALSP ERROR
Full scale point Calibration error.
97
FORMAT ERROR
No free format is program.
98
NO DATA IN REPORT
There is no data in report when printing report.
99
EXCEED WEIGHT QUOTA
CN only. Please reset weight quota.
label roll
No free format is programs. Set a free format or use standard format.
Not enough memory. Expand memory or delete unnecessary data.
No total price for item. Unit price, weight or quantity is 0.
SM100
ERROR MESSAGE
FATAL MESSAGE No.
Fatal Error Message
F002
External flash memory erase error
F003
External flash memory program error
F004
External flash memory program error
F005
Internal RAM read/write error
F006
External RAM read/write error
F007
External ethernet IC read/write error