The SGS Group of companies is the global leader and innovator in the field of inspection, testing & verification. The group is operating its network in more than 140 countries through out the globe with 274 subsidiaries, more than 1150 offices 320 laboratories and over 3200 full time experienced and qualified personnel. SGS has been providing services in India for last 50 yrs. as SGS India Private Limited and has 51 offices, 32 laboratories l aboratories & over 2000 Staff. SGS India Pvt. Ltd. provides services in various sectors. OIL, GAS AND CHEMICAL SERVICES SGS – Oil, Gas & Chemical services is a part of SGS group which provides inspection, measurement / calibration, technical, analytical & operational services to the Process, Petroleum, Petrochemical, Gas and related industries. In association with our affiliates worldwide, we provide comprehensive service package related to land tank calibration by using the ORLM technique. Hence with strong base in India we hereby introduce ourselves to cater to your requirement related to storage Tank calibration by ORLM technique. The method is approved b by y API & ISO. SGS India Pvt. Ltd. OGC is an approved license holder of Department of Legal Metrology (Weights and Measurement Dept.) of Maharashtra & Gujarat States for carrying out the calibration of storage tanks. The present client data base includes Oil & Chemicals Terminals, Refineries, Petrochemical plants, Oil depots etc. Our Esteemed customers includeinclud e
BG EXPLORATION & PRODUCTION LTD. HAZIRA LNG NIKO RESOURCES ESSAR STEEL CAIRN ENERGY TORRENT POWER SUJEN RIL, CHENNAI IOCL IOTL SHELL SRILANKA MRPL CPCL, CHENNAI BPCL, VIZAG ETTPL, CHENNAI BPCL, CHENNAI IOCL, MADURAI IMC, MANGALORE IOCL, NAGAPATTINAM BPCL, HYDERABAD
------------------------------------------------------------------------------------------WHEN YOU NEED TO BE SURE
VERTICAL CYLINDRICAL STORAGE TANK CALIBRATION AS PER API MPMS Ch.2 SEC 2D 1.1 MEASUREMENT AND CALIBRATION INSTRUMENTS OF VERTICAL STORAGE TANKS
EODR(ELECTRO-OPTICAL DISTANCE RANGING METHOD) uses following instruments to execute the tank calibration jobs-
------------------------------------------------------------------------------------------WHEN YOU NEED TO BE SURE
1.2.
FIELD MEASUREMENT (INTERNAL)
1.2.1
Shell calibration
Ensure the tank wall is clean and free from slag, grease, dirt or oil patches and tank environment to be free from welding fumes, as it may cause errors in measurement. This method is only suitable for tanks where the internal diameter does not vary by more than 1%. Firstly, positioning of instrument Total Station is done at a point near to the centre of the tank & it is to be ensured that there is minimum obstruction during the course of calibration. After positioning, leveling of instrument is done with respect to the axis of tank surface. Then target point is selected over the tank bottom shell & circumference of tank is measured with respect to the same. Consequently, programming of total station is configured for measuring the remaining circumference of each shell. The data collected by the Total station will be recorded in the PCMCIA card which is inserted into the total station. This data will then be processed to give output information such as the radius, roundness and the tilt of the respective tank.
PICTORIAL VIEW OF MEASUREMENT BY TOTAL STATION-
------------------------------------------------------------------------------------------WHEN YOU NEED TO BE SURE
1.2.2
TANK BOTTOM MEASUREMENT
The tank bottom measurement can be carried out by Total Station as well as Rotating Laser. Measurement by Total Station – With respect to the circumference of the tank, the tank bottom is divided into radial stations at equi-distance. Official Datum plate elevation and instrument (ATG) datum elevation is taken before and after the tank bottom survey. These two elevations should agree to a tolerance of not more than 2 mm as per the specification (API Chapter 2, Section 2D) provided by manufacturer. After positions of radial stations have been marked, Total Station is configured to measuring mode & for each station, readings are taken by the instrument. These readings are later used to generate the profile of the tank bottom surface & consequently, volume is computed for the same. Measurement by Rotating Laser The Rotating Laser is first positioned at the centre or near to it. Then, the number of radial stations is selected according to the circumference of the tank. Datum plate elevation is checked by Rotating Laser & with reference to the same, the readings are taken at each radial stations. All the data acquired are compiled & profile of tank is generated. Consequently, the bottom volume is computed.
1.2.3
Deadwood Measurement
The entire deadwood is accurately accounted for as to the volume and location in order to permit adequate allowances for volumes of liquid displaced by various objects and allocation of these effects at various elevations within the tanks.
1.2.4 Development of Capacity Table Development of capacity tables is based on the field data compiled & generated by the software incorporating necessary corrections factors. The calibration tables are presented for the required computation interval. The software allows calculations to be carried out using ISO/IP or API/ASTM with various options of units for presentation.
CORRECTIONS INCORPORATED WHILE COMPUTATION OF CALIBRATION CHARTS:
STEP OVER CORRECTIONS FOR VERTICAL WELDS PLATE THICKNESS CORRECTION TEMPERATURE CORRECTION LIQUID HEAD CORRECTION TILT CORRECTION
------------------------------------------------------------------------------------------WHEN YOU NEED TO BE SURE
2.1 ADVANTAGES 1. HARDWARE/ EQUIPMENT Fully Digital with Touch Screen c/w Robotic function features. 2. Output/Data Collection Digital Data, i.e. co-ordinates (tempering free). 3. PRODUCTIVITY LEVEL Higher as 2-3 tanks of 20 Dia tanks can be easily calibrated internally. Tanks having more than 20 diameters can be calibrated internally in a single day. External calibrations of tanks can also done within 1-2 days depending on diameters of tank. 4. Accuracy Higher as digital data is consistent.
5. SAFETY LEVEL AT WORK Cancel out random movements so, no eruption of any eventuality.