B. McLauchlan TAFE SI 2006
Authors Note: Note: These notes notes are provided for for student use in in National Module EA 7766L The notes are not to be reproduced in any form without the author’s written permission. While every attempt has been made to ensure accuracy of the materials in these notes, the author accepts no responsiblity for any liability or loss in respect to the application of the information presented.
© Brian S. McLauchlan 1990 - 2007
TAFE Mechanical Engineering
1
B. McLauchlan TAFE SI 2006
TABLE OF SYMBOLS δ .......................... .......................... ..density, sity, kg/m kg/m3
f........................... ........................... ..fre ..freq quency, cy, Hz f f f ............... ........................ .............. .....forci forcing ng fre frequency, ncy, Hz Hz f n ............................natural frequency, Hz k............... ....................... .............. ......sp spri rin ng cons consta tant, N/m N/m m....................... m............................ .....m mass, ss, kg ϖ ........ ........... ....... ........ ........ ........ .....an .angu gullar fre f requ que ency, ncy, ra rad/se d/sec
x.............................displacement in meters X ....... ........... ........ ........ ....... ....... ...... ..displace displacement in me meters ters at at tim time t v.............................velocity in m/sec a.............................acceleration in m/sec2 y.................. y.......................... ...........po ...positi sition on in i n meters
TAFE Mechanical Engineering
2
B. McLauchlan TAFE SI 2006
Table Table of Contents
Vibration - Concepts.............................. Concepts ............................................................. .................................. ... 4 Vibration - Measurement.............. Measurement............................................. .......................................... ........... 13 Instrume Instrumentati ntation on For Vibration Vibration Measuremen Measurementt .............. ...................... ............... ....... 27 Vibration Isolation................................. Isolation.. .............................................................. ................................. 43 Vibration Vibration - Human Human Effects ............... ....................... ............... .............. ............... ............... ......... .. 60 Balancing Of Machinery.......................... Machinery......................................................... ................................. 67 Balancing Of Machinery.......................... Machinery......................................................... ................................. 67 Vibration Vibration Specifica Specification tion ............... ....................... ............... ............... ............... .............. .............. ....... 74 Appendix Appendix ............... ...................... ............... ............... ............... ............... .............. ............... ............... .......... ... 78 Vibration Vibration Exercise Exercises s ............... ....................... ............... ............... ............... ............... ............... ........... .... 79 Glossary Glossary Of Vibration Vibration Terms .............. ...................... ............... ............... ............... .............. ....... 84
TAFE Mechanical Engineering
3
B. McLauchlan TAFE SI 2006
Vibration - Concepts 1.1 Introduction
Many machines and processes in engineering generate vibration . In a few cases this vibration is intentional as in vibrating sorting screens, ultrasonic cleaners and earth compaction machines . Mostly though, the vibration is an undesireable effect. The vibration generated can cause a number of effects that are troublesome . The most serious serious are related to fatigue and injury to humans exposed either to the vibration directly or the effects of noise caused by the vibration . Vibration may also also contribute contribute to excessive wear, fatigue failure and other premature failure of machine components. Many vibration problems are due to inadequate engineering design of a product, or the use of a machine in a manner that has not considered the possible effect of vibration. In this course we will investigate the basics of vibration with the intent of being able to measure measure and assess problem areas . There are many very complex vibration problems that require sophisticated computer modelling modelling to solve. It is often the case however that awareness at the design stage will eliminate or reduce the vibration to a level that is acceptable, using relatively simple methods. 1.2 Simple Harmonic Oscillation
The simple model of a spring and a mass may be used to investigate the basic basic ideas ideas of vibration . In this model a spring of of spring constant constant k, suspends suspends a mass mass m . Spring constant constant is measured in Newtons / meter (N/m) . Mass is of course, in kilograms. Figure one shows shows this model model with a spring constant of 400 N/m and a mass of 4 kg . If the mass is displaced down, then released, released, the mass will oscillate at a frequency that is independant of the amount of initial displacement. This frequency is called the NATURAL FREQUENCY. FREQUENCY. The equation that determines the natural frequency of this system involves both both the spring spring constant and the mass. mass. As the spring spring constant is increased, so the natural frequency increases.
TAFE Mechanical Engineering
4
B. McLauchlan TAFE SI 2006
k
m
Figure 1.1 - Vibrating Spring/Mass System The effect of the increased mass is to decrease the natural frequency so that the form of the relationship is:
fn =
1 k 2π m
Our system in figure one thus has a natural frequency frequency of 1.6 Hz. Note that the angular frequency, ϖ, is related to the frequency f by the factor 2 π, so that this equation can be written as:
ω = 2π f
so
ω
=
m
If our simple system is set in motion we may measure the displacement displacement over a period period of time. time. We will find find that the displacement repeats after a time called the PERIOD, which is the inverse of frequency frequency . In the case of our example in figure one, the frequency is 1.6 Hz and so the period is 0.625 seconds. The fact that the vibration repeats is described by the term PERIODIC and the motion of one period is called a CYCLE. CYCLE. If we plot the cycle of displacement over the time of one period we will find that the result result is a curve like that in figure 2. This is a curve that is able to be described by the familiar sine function.
x =A sin sin ( ϖ t )
TAFE Mechanical Engineering
5
B. McLauchlan TAFE SI 2006
where the magnitude x goes from a maximum value of A to a minimum of - A over a cycle related related to an angular angular function function ω and the time t . Where the object object moves in this manner it is known as SIMPLE HARMONIC MOTION.
V i b r a t i o n
time
Figure 1.2 Displacement / Time For A Periodic Vibration
For displacement the sine function can be written as:
X = A sin ( ϖ t ) where X - displacement from rest position, m at time t. A - peak displacement, displacement, m. ϖ - angular frequency, rad/sec t - time, seconds.
1.3 1.3 Displacement - Veloc Veloc ity - Acceleration
In most considerations of vibration problems we will deal with one of three possible possible parameters parameters for vibration measurement. measurement. The first we have described above. The other two are velocity velocity and acceleration. acceleration. To understand understand the relationship relationship of the the three parameters, displacement, velocity and acceleration is important to an understanding of vibration. TAFE Mechanical Engineering
6
B. McLauchlan TAFE SI 2006
Displacement Displacement - A measure of the distance a vibrating body moves. Velocity - A measure of the speed of motion of a vibrating body. Acceleration - A measure of the rate of change of speed (velocity) of a vibrating body. The equations for each can be written as shown shown below. ( Note: see appendix A for details of the derivation of these equations.)
X = Asin(ω t)
displacement
•
X = Aω cos(ω t)
velocity
••
X = − Aω 2 sin(ω t)
acceleration
For a particular vibration, the parameters in these equations, A and ϖ, are constant constant and common. common. This means that these three measures of of vibrations are always always related in a predictable way. way. This is fine but does all this mathematics mean much in a real problem? Well, let's consider the physical significance of these equations.
TAFE Mechanical Engineering
7
B. McLauchlan TAFE SI 2006
V i b r a t i o n
10 8 6 4 2 0 -2 -4 -6 -8 -10 -10 time Displacement
V elocity
A cceleration
Figure 1.3 Relationship Of Displacement, Velocity & Acceleration In figure 1.3, each of the above equations has been plotted for one cycle, with the displacement displacement as the reference reference for time zero. For our vibrating spring - mass system this diagram shows that : i.at time zero, the velocity is maximum with displacement and acceleration acceleration zero. The mass is moving past its rest point. point. ii.at 1/4 cycle later the velocity has reduced to zero with displacement maximum and acceleration maximum in the other direction. The mass has stopped stopped at the peak of a cycle. iii.at 1/2 cycle the displacement and acceleration acceleration have again become zero zero while the velocity velocity is a maximum. maximum. The mass is again again passing its rest point. iv.at 3/4 cycle the displacement is at a negative maximum with acceleration a maximum in the opposite direction. direction. The velocity is zero. v.the cycle is complete complete with displacement, displacement, velocity velocity and acceleration acceleration at their original values. We see from this that the mathematics describes what is happening to the mass at any time in the cycle. cycle. We will use the the various measures of vibration - displacement, displacement, velocity and acceleration to assess problems of machine vibration.
TAFE Mechanical Engineering
8
B. McLauchlan TAFE SI 2006
1.4 Unit s
Before any assessment can be made however, we must be aware of the units used in vibration. vibration. These are summarised in the table below.
PARAMETER
UNITS USED
DISPLACEMENT
m , mm ,
VELOCITY
m/sec , mm/sec
ACCELERATION
m/sec2
,
um
" g " ( % of 9.8
2
m/sec ) Table 1.1 Units For Vibration Measurement We will make use of these units but must first consider further the problem of our vibrating spring mass system. 1.5 1.5 Forced Vibration s
So far we have caused the spring mass system to vibrate only at its natural frequency. frequency. The mass is displaced displaced and then released causing causing a series of oscillations. oscillations. What happens if if the system is pushed pushed by a force that also oscillates ? Figure 1.4 shows the system acted on by an external force causing displacement of the base, that has a periodic nature.
x(t)
m
x'(t)
Figure 1.4 Forced Oscillations Of The Spring Mass System
We might expect some oscillation and that it will depend on the frequency of the "EXCITING FORCE" and the natural frequency of our spring mass mass system. If the differential differential equation for the system TAFE Mechanical Engineering
9
B. McLauchlan TAFE SI 2006
is solved and the frequency response for the system is plotted we have a diagram like that shown in figure 1.5. Amp lif ic ati on 10
1
0.1 0.1
0.01 0.1
1
10
Frequency Ratio
Figure 1.5 Response Of 1 Degree Of Freedom System
Figure 1.5 calls our spring - mass system a ONE DEGREE OF FREEDOM SYSTEM because the motion of the mass is described by only one displacement displacement measurement. measurement. (ie displacement displacement is along one axis only) The response diagram shows some important information that shall now be considered. First, the mass has a response which theoretically theoretically goes to infinity when the exciting force coincides in frequency with the natural frequency. This response response is known as RESONANCE. In practice the response at resonance will not be infinite due to losses in other parts of the system. However the resonant behaviour is significant because the system responds with a greater displacement than that applied! This is clearly undesirable. It can also be seen that below the resonance frequency, the response climbs steadily and is always more than the applied displacement. displacemen t. Above resonance however, the response drops TAFE Mechanical Engineering
10
B. McLauchlan TAFE SI 2006
rapidly, showing less and less displacement with increases in frequency. How can this knowledge help us ? If the frequency of the forced vibration is always above that of the NATURAL FREQUENCY of the system, then the vibration of the mass is less than the the applied vibration. In fact, if the applied applied vibration is more than 3 times the natural frequency, the vibration of the spring/mass is less than 10% of the input vibration. This means that we have ISOLATED the mass from the vibration to the extent that only 10% of the vibration gets to the mass. A similar situation applies if the mass in our system has the forcing frequency applied applied to it directly. Consider a small diesel engine. When operating, the rotating and reciprocating parts of the engine will cause a vibration vibration at the running speed of the engine. engine. In our simple model the engine is the mass and provides also the forced vibration. We wish to isolate the vibration vibration of the engine from the mounting base of the engine. If we use a spring mounting mounting with a stiffness that that ensures a NATURAL FREQUENCY of 3 times less than that of the engine running frequency, we will ISOLATE the mounting base of the engine from 90% of the vibration produced by the engine.
1.6 Damping Dampin g
In the section above, it was observed that the vibration at resonance is limited by the system losses. losses. The loss can be controlled to provide a more suitable frequency reponse for the system. The provision of of suitable energy energy losses in a system is termed DAMPING. DAMPING. Damping will have the effect effect shown in figure 1.6. In the figure the term DAMPING RATIO is used to express the amount of damping used. The value where where damping ratio is equal equal to 1.0 is called CRITICAL DAMPING.
TAFE Mechanical Engineering
11
B. McLauchlan TAFE SI 2006
Critical damping is defined by:
ccritical = 2
km
Damping greater than critical will have a ratio greater than 1.0. Damping less less than critical, critical, will have a ratio less less than 1.0. Damping causes the response at natural frequency to be reduced but causes the shape of of the response response curve to alter alter at other points. points. This will be discussed in detail in section 0.05 0
Am pl if ic ati on Rati o 10.00
0.1 0.2 0.5 1.00
1.0
Damping Ratio 1.0
0.10
0.5
0.2
0.1 0.05 0
0.01 0.1
1
10
Frequency Ratio
Figure 1.6 Response to Forced Vibration (1 DOF Spring-Mass) Spring-Mass)
TAFE Mechanical Engineering
12
B. McLauchlan TAFE SI 2006
Vibration - Measurement 2.1 Introduction
The vibration of machines can be considered as an oscillatory motion of part part or all of the machine. machine. So far we have have seen that a simple vibrating system, the spring/mass system, has a harmonic motion. This motion can also also be termed PERIODIC because because it repeats itself itself exactly over fixed fixed time period. In this section section we will consider what other vibratory motions are possible and the basic ideas for analysing these motions. 2.2 What Ar e We Measur Measur ing in g ?
The motion of the vibrating system is measured with the units described in a previous section section (1.4). What was not specified was what amplitude was to be specified with with these units. units. Figure 2.1 shows a sinusoidal waveform with the possible ways of measuring amplitude. 10 V i b r a t i o n
8 6 4 2
Peak to peak
Peak RMS
0 -2 -4 -6 -8 -10 -10 time
Figure 2.1 Measuring Vibration Amplitude
The equations of motion specify the PEAK amplitude (see 1.3) but when measuring our measuring device could be constructed to measure any of PEAK, PEAK to PEAK or RMS amplitude values. Many measuring systems measure RMS (Root Mean Square) values because this value is proportional to the power in the vibrations of a system. This means that care should be taken to establish what is being measured by an instrument. instrument. In particular, when the procedure of of TAFE Mechanical Engineering
13
B. McLauchlan TAFE SI 2006
converting between displacement, displacement, velocity and acceleration is used, the correct amplitude must be known for correct integration. 2.3 2.3 Harmoni Harmoni c Perio Perio dic Vib ration
The vibration that has been described so far, that has a single frequency and is sinusoidal can also be described as harmonic periodic vibration. vibration. Harmonic is an alternative term for sinusoidal, sinusoidal, and periodic means repeating regularly. A sinusoid is able to be described precisely by knowing its frequency and amplitude. 2.4 2.4 Vibration That Is Not Harmo Harmo nic
Our simple spring mass system gives rise to harmonic periodic vibrations. This is not the only only possible type of vibration that we we may encounter. encounter. In fact it is probably probably the least likely likely to be found in most engineering systems. We should first consider the possiblity of a vibration that is periodic but not harmonic. harmonic. That is, its motion is not described by a simple sinusoidal signal, but the motion may repeat itself continuously in time. Such a vibration can be termed periodic periodic and an example example is shown in figure 2.3. Am pl it ud e 10
5
0 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
-5
-10
-15
time
Figure 2.3 Periodic Non Harmonic Vibration
If we wish to determine the frequency content of this signal, how could it be done done ? A mathematician called called Fourier determined determined that for any complex signal, its frequency content could be found by considering the complex signal as the sum of a series of sine and cosine functions. functions. In the example above, which is the acceleration acceleration of the piston in an engine, the signal can be analysed into two sine TAFE Mechanical Engineering
14
B. McLauchlan TAFE SI 2006
signals of differing amplitude and frequency. In this example the Fourier analysis can be seen to give the wave form in figure 2.3 using two harmonically related related sinewaves. sinewaves. This is illustrated illustrated in figure 2.4.
10
5
0 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
-5
Amp li tu de -10 -10
-15 -15
time
Figure 2.4 Fourier Components Of A Signal
So far we have have dealt with relatively relatively simple types of vibration. Much of the time, however, we will be dealing with a vibration that is much more irregular irregular than those those we have seen seen previously. This irregular type of vibration is termed RANDOM VIBRATION. Random vibration is characterised by irregular motion cycles that never repeat repeat themselves exactly. This means that the the analysis will be somewhat somewhat more complicated. complicated. In view of this added added complexity, you may be tempted to ask, how common is this type of vibration?. Consider the motion of any form of vehicle used for transport, such as cars, trains or aircraft. It is rare that any any of these vehicles vehicles will experience purely periodic vibrations. In fact much design design effort is expended to avoid certain periodic vibration that may result in resonance and consequent damage due to excessive vibration amplitude. Vehicle Car Aircraft Ship Rail wagon
Common periodic vibration Suspension resonance from corrugated road surface Body vibration due to turbulence Roll due to sea swells Yaw instability above design speed TAFE Mechanical Engineering
15
B. McLauchlan TAFE SI 2006
Much machinery vibration can occur as random vibration with added periodic components. components. It is thus a common common and important important type of vibration to consider in engineering. Random vibration may have a signal that is like that of figure 2.6. This shows the complex nature of the motion of a component experiencing this type of vibration.
Figure 2.6 Typical Random Vibration Signal
2.5 Analysis of Vibration Signals
Recall that a periodic harmonic signal can be completely specified by an amplitude and and a frequency. frequency. For other other signals signals we are also interested in these parameters. To help express these we use a special graph called a frequency spectrum that plots amplitude on the vertical axis and frequency on the horizontal axis.
TAFE Mechanical Engineering
16
B. McLauchlan TAFE SI 2006
2.5. 2.5.1 1 Spectru Spectru m Of A Periodi c, Harmo Harmo nic Vibratio n
What does the frequency spectrum of the vibration of our spring mass system look like? We have only one frequency and a single amplitude. The spectrum spectrum thus appears appears as a single line at the natural frequency of the spring mass system with an amplitude depending on the size of the motion of the mass. Figure 2.2 shows a typical spectrum for our simple spring mass system. Amplitude
Frequenc Figure 2.2 Frequency Spectrum Of Harmonic Vibration
If a complex periodic wave is broken up into its' Fourier components, a frequency spectrum can also be constructed. If each Fourier component is a sinusoidal signal of a certain amplitude the spectrum will will be a series series of peaks on the spectrum. spectrum. The example in figure 2.4 is represented as a frequency spectrum in figure 2.5. Amplitude
f1
f2
F re uenc
Figure 2.5 Frequency Spectrum For The Signal Of Fig.2.3
In the frequency spectra shown above we have indicated an amplitude. This could be the peak amplitude of the signal or it could be the RMS amplitude. TAFE Mechanical Engineering
17
B. McLauchlan TAFE SI 2006
Because the Fourier spectral analysis breaks a complex wave into sine or cosine components the RMS or peak amplitude can be easily converted from one to the other.
Time Amplitude
f1 f2
Frequency
Figure 2.7 Creating a Frequency Spectrum
Figure 2.7 shows how the signal, which is varying in time, is broken up into components which can be shown on the frequency sprectrum graph. The frequency spectrum is like a cross section at a point in time of all the components that make up the signal being studied. How can we analyse a random vibration signal ? What do we use for amplitude ? What do we we use for for frequency ? It is clear clear that when we have a periodic signal, we can predict from its appearance over one cycle, cycle, the future cycles. cycles. With a random signal signal this is not possible. Theoretically we have a signal that must be infinite in length and the whole signal should be studied.
TAFE Mechanical Engineering
18
B. McLauchlan TAFE SI 2006
Fortunately statistics can be used to analyse the properties of this infinite signal by by using using a sample from the signal. Like most statistical procedures this means that the sample we take must be a representative representative sample, otherwise our our analysis will be inaccurate. inaccurate.
For example, if I intended to use a statistical method to find the most popular food in Australia and I asked only adult males over 70 in Alaska for their opinion my results would not be particularly valuable !
Similarly, when analysing vibration signals I must use a good sample, usually determined by having a long enough sample where conditions are stabilised. stabilised. This means means that that the following will be approximately constant: Speed of a machine machine (eg velocity of a car; rpm of a motor) Loading on a machine (eg power output of an engine) Forced vibration (eg quality of a road surface that a car travels on) Just what is a long enough sample under these conditions is dependant on the frequency content of the signal and and will be further discussed in the data analysis section, but basically requires that lower frequencies require longer recording times for the same accuracy as higher frequencies. (see page 23)
2.5. 2.5.2 2 Analysis Of Random Random Vibratio n Signals
A random vibration signal may be analysed using an amplitude analysis and/or a frequency analysis method. The simplest means of assessing random vibration is to measure the RMS signal level over a period of time. This will give and idea of the average average energy energy content of the signal and is useful for many applications. An analysis of the PROBABILITY of occurence of a particular amplitude value will give an asessment of what sort of vibration levels can be expected and how frequently a particular level will occur. For example, a motor motor car travelling along a road will have some vibration vibration felt by the passengers continuously. Large bumps bumps will give larger vibration levels, but less frequently. This type of analysis commonly results in a normal curve that is met frequently in naturally occurring processes. Figure 2.8 shows a Normal ( or Gaussian) curve generated by this type of analysis. TAFE Mechanical Engineering
19
B. McLauchlan TAFE SI 2006
Frequency
M ean or average
Spread
Vibration Amplitude Figure 2.8 Normal Curve From Vibration Amplitude Analysis
Like the other signals we have dealt with, we are commonly also interested in the frequency content of the random vibration signal.Fortunately, Fourier analysis is applicable to random signals in the same same way as other data. The Fourier Fourier analysis of a random random signal results in an infinite number of sinusoidal components of different amplitudes and frequencies. frequencies. The resulting spectrum is theoretically a continuous continuous curve rather than single line values. values. Figure 2.9 shows the type of curve that could result from this type of analysis.
TAFE Mechanical Engineering
20
B. McLauchlan TAFE SI 2006
Amplitude
Frequenc Figure 2.9 Frequency Spectrum Spectrum For Random Random Vibration
Because we cannot deal with infinite numbers of amplitudes and frequencies, this curve is usually approximated by a series of lines representing frequency values. A frequency spectrum for a random vibration is sometimes called a spectral density density or power power spectrum. spectrum. These are all measures of the frequency content of a random vibration signal.
2.5.3 Filtering
We have seen how to classify the time behaviour of a signal and that it can be broken into frequency components and expressed as a frequency spectrum. The question then arises as to how are we going to achieve the frequency analysis to get a frequency spectrum. The basic idea of frequency analysis rests rests on an understanding understanding of of filters. We have have heard of filters filters in mechanical mechanical systems. These are used to limit the particle size passed through a fuel or lubricating system, for example. In a similar way electronic filters can be made which restrict the frequencies that are allowed allowed to pass pass through them. A filter may be either a LOW PASS, HIGH PASS or BAND PASS FILTER. The FREQUENCY RESPONSE CURVES for these types of filter are illustrated in figure 2.10. The low pass filter will allow only frequencies
TAFE Mechanical Engineering
21
B. McLauchlan TAFE SI 2006
up to a certain certain value to pass through. Any higher will will be blocked. blocked. In a similar manner the high pass filter will allow only those frequencies above a certain certain level to pass through. The point where where the frequencies will become blocked can be changed by design. A
Low P ass
Hi h P ass
Band P ass
Figure 2.10 Low Pass, High Pass And Band Pass Filters
The band pass filter can be considered to be a combination of a low pass filter and a high pass filter. This gives a filter that that will pass pass frequencies over only a narrow range. We can make such a narrow band filter with either a fixed value of range or may make it a fixed width and variable frequency so we can tune it to the band that we want.
It is this band pass filter that makes frequency analysis possible. If a complex signal is measured by a transducer, the electronic signal representing the transducer signal may be passed through a band pass filter filter and the level level measured. measured. This level will be only the amplitude of the frequencies that are passed by the filter. If a range of of filters are used used then the whole range of frequency frequency of of interest can can be covered covered in small frequency frequency increments. increments. The most common set of band pass filters used are in octave or 1/3 octave bands. An octave covers a frequency range such that the lowest frequency in the range is half the value of the highest frequency in the range.
Filters for octave bands are generally labelled by the middle or center frequency frequency of the whole band. One third octave band band filters break each each octave band range into three. three. Octave and 1/3 octave filters are more commonly used for noise measurement, however 1/3 octave bands are used in a number of standards, especially those concerned with human effects of vibration. TAFE Mechanical Engineering
22
B. McLauchlan TAFE SI 2006
2.5. 2.5.4 4 Narro Narro w B and An alysis
To achieve the discrimination needed for vibration analysis, filters with narrow bands are needed. This can be achieved by constructing more filters OR by using a technique known as Fourier Analysis. Fourier Analysis is a mathematical technique that can determine frequency content in as narrow bands as desired. It is usually achieved using electronic systems such as an FFT analyser or a computer. (note : FFT is Fast Fourier Transform, a mathematical simplification to make the calculation quicker)
2.5. 2.5.5 5 Limit ations Of Frequency Analys is
The use of any filtering technique for frequency analysis must consider the limitations limitations of the equipment. equipment. Any filter does not cut off completely those frequencies frequencies outside its bandwidth. There is also also a limitation on the minimum time required for a filter to accurately determine the magnitude magnitude of of the filtered data. data. This is called the averaging time.
Limitations Of FFT Analysis
Due to the popularity of FFT analysis it is considered essential to mention some important limitations in use of this technique. a. a averaging veraging time - the averaging time must be carefully selected to ensure ensure that that the amplitude is accurately accurately measured. For many many acoustic measurements this will not be significant but the same averaging for lower frequency analysis, often the case for vibration work, may cause significant errors. The FFT process must average (sometimes called "ensemble averaging") over a number of spectra to give accurate amplitude results. The following should be considered:
Number ber of spe spectra
Error rror 95% 95% c.i. c.i .
8....... ........ 2.8d 2.8dB 16..... ........ 2.0d 2.0dB 32... 32..... .. ........ ........ 1.46d 1.46dB B 64... 64..... .. ........ ........ 1.06d 1.06dB B
L ength ength of data data record for full ull scal scale freque requency 100Hz 100Hz 32 64 128 128 256 256
1kHz 3.2 6.4 12.8 12.8 25.6 25.6
10kH 10kHz z 0.32 0.64 1.28 1.28 2.56 2.56 TAFE Mechanical Engineering
23
B. McLauchlan TAFE SI 2006
128... 128... ........ ........ 0.74d 0.74dB B 256... 256... ........ ........ 0.54 0.54 dB
512 512 51.2 51.2 5.12 5.12 1024 1024 102.4 102.4 10.24 10.24 |______________________| tim time in seconds
Notes: c.i. - confidence interval,this means that all data are within the error limit specified with 95% confidence. (this means that there is a 95% probability that the error will be no greater than that listed) L ength ength of data data record - means how long long the recordi recording ng of the the data data must be, wi with operating conditions constant, to give enough time for the analysis.
Table 2.2 Averaging Times For FFT Analysers
TAFE Mechanical Engineering
24
B. McLauchlan TAFE SI 2006
Example: This table table shows shows that for 95% confidence that if I require require the accuracy of the data to be no worse than +/- 0.54 dB, and I set a maximum frequency of 1000 Hz on the analyser, I will require 256 averages. These 256 averages will will take 102.4 seconds seconds of data or 102.4/60 = 1.7 minutes.
The table has has some important important consequences. consequences. The time limits often cause problems for data recording at low frequency. For instance,if the analyser is now used at 100 Hz full scale setting,a recording of 17 MINUTES is required required for the the highest accuracy! accuracy! ( 1024/60 = 17) Often then, then, a trade off of accuracy accuracy and time recording recording must must made.
be
b. windows - The FFT process is a mathematical simplification. It relies on the correct data being input input to give accurate answers. answers. In the FFT process a block of data is converted to digital information and then frequency frequency analysis analysis is performed. performed. The next block block of data is treated similarly and then averaged with the first block. If the two blocks of data do not "fit together" like acontinuous wave, the FFT analysis process will calculate non- existing frequencies !
To overcome the problem of data blocks with "non - fitting" ends a process called called WINDOWING is used. This process ensures that data data always fits together. A "window" "window" here is a mathematical mathematical weighting weighting curve that is used to ensure that the sampling that occurs with the FFT averaging process process still has acceptable acceptable accuracy. accuracy. It uses windows called Hanning, Hamming or rectangular. The Hanning and Hamming windows are for use with continuous signals. The rectangular window is usually only used for analysis of impulsive of impulsive signals.
c. Anti - aliasing There is always a problem with limiting the maximum frequency frequency of a signal when converting converting from analogue analogue to digital, as required required by FFT analysers and computers. When a signal signal is to be digitised it is converted to a series of numbers. Each number represents a sample point of the continuous wave that is the acoustic acoustic or vibration data. data. If the sample points points are taken too far apart the frequency data is not able to be accurately specified. TAFE Mechanical Engineering
25
B. McLauchlan TAFE SI 2006
This is because the sample data may represent the signal frequency measured or multiples of that signal at higher frequency. To prevent aliasing,the higher frequency components must be removed by a LOW PASS FILTER. This filter is usually provided by the manufacturers of FFT analysers but must be provided also when using a computer computer for FFT analysis. This aspect is often overlooked overlooked when using computer based systems and can lead to serious errors. The frequency frequency of sampling should then be set to be at least twice the limiting frequency of the low pass filter. It is preferable in fact to set set the sample frequency higher for greater confidence in the frequency data. The problem of aliasing should not be overlooked as incorrect data analysis will result if aliased data is used. Like most instrumentation, it is possible to get out values from frequency analysers that seem reasonable but may not be accurate. Ensure that the correct procedure is used for any frequency analysis.
Sample Period
Sample Period time
time
Signal constructed constructed from samples.
Signal constructed constructed from samples.
Figure 2.10 Sampling to Eliminate Aliasing When When Digitising
TAFE Mechanical Engineering
26
B. McLauchlan TAFE SI 2006
Instru mentation For Vibratio n Measurement Measurement 3.1 Transducers A transducer transducer is a device that converts converts a small amount of the energy of the quantity to be measured into another form of energy, usually usually electrical. electrical. This conversion conversion is to allow for ease of measurement measurement as typically it is easier to record and analyse electrical signals.
In vibration measurement, measurement, we may wish to measure the the vibration displacement, displacement, velocity or acceleration.The acceleration.The choice of measurement measurement will depend on how the data obtained obtained from the measurement wil wil be used. Because of this choice we have transducers suitable for measuring each quantity. quantity. The transducers transducers may make use of of the following techniques for energy conversion: a.piezo - electric effect b.piezo - resistive effect (silicon strain gauge) c.inductance d.capacitance e.resistance f.optical
3.1. 3.1.1 1 Disp lacement Transducers
These may be either non non - contact contact inductive or capacitance capacitance types, resistance types or may use a DIFFERENTIAL TRANSFORMER to measure displacement. Alternately, double integration of an accelerometer accelerometer signal may be used to provide displacement. The non-contact non-contact types are often used used to measure measure shaft postion in rotating machinery. They operate by sensing the change in a magnetic or electrical electrical field between between the sensor sensor and the shaft as the shaft varies varies its motion relative relative to its bearings. The differential differential transformer uses a set set of three coils of wire wound on a cylinder common to all. (fig 3.1) An alternating voltage is fed to the the center center winding winding at a fixed frequency and level. level. A slug slug moves moves inside the cylinder and its position determines the proportion of signal induced in each of the other two coils.
TAFE Mechanical Engineering
27
B. McLauchlan TAFE SI 2006
Output Slug
Input
Figure 3.1 Differential Transformer Displacement Transducer
The slugs' slugs' displacement displacement is thus able to be determined. determined. In use, the the coils are attached attached to a component component and the slug to another so that the relative displacement displacement between between the components is measured. Resistance types use an electrical POTENTIOMETER (variable resistor ) that moves in response response to the displacement applied. The potentiometer potentiometer is supplied with a steady voltage and the varying resistance provides a varying voltage signal proportional to displacement. The differential differential transformer transformer and potentiometer potentiometer types types are usually used for relatively relatively low frequency frequency measurement measurement up to about 20 Hz. Displacements Displacements up to about 300 mm can be measured. Higher frequencies are possible with the other types (up to 200kHz) but often this is possible for only very small displacements. 3.1. 3.1.2 2 Velocity Transducers
Velocity measurement measurement may make use of all the types of transducers above, excepting the potentiometer potentiometer type. In addition, the signal from an acceleromete accelerometerr may be integrated to give velocity. 3.1. 3.1.3 3 Acc eleratio eleratio n Transducers
Probably the most common common vibration vibration measuring measuring transducer transducer is the accelerometer. accelerometer. The measurement measurement of acceleration can be made by many types of transducers transducers and the signal signal is able to be integrated to to give either either velocity velocity or displacement signals. (Note: although theoretically possible, the differentiation of signals from displacement to velocity etc. are usually usually avoided due to stability problems with electronic differentiation) TAFE Mechanical Engineering
28
B. McLauchlan TAFE SI 2006
Piezo Electric Accelerometers
These are a very common common type of of accelerometer accelerometer with a wide range of frequency frequency small size and rugged rugged construction. construction. They use a mass mass that is attached attached to a crystal of of material that varies its charge in response to mechanical stress. stress. (fig 3.2) If the mass is accelerated, the crystal provides a signal proportional to the acceleration. acceleration.
Piezo accelerometers accelerometers cover a wide wide range of of sensitivity from about .00005 m/sec.sec (5 x 10 g) to 200, 000 m/sec.sec (20, 400g). Electronics Mass Piezocrystal
Base Connector
Figure 3.2 Basic Arrangement of a Piezoelectric Accelerometer
Piezo Resistive Accelerometers Accelerometers
These types of acceleromete accelerometerr use use a silicon strain gauge. This type type of strain strain gauge gauge is not the metal metal foil foil type commonly used for engineering strain measurements. measurements. The metal foil type is more linear and much easier to handle than the silicon type.For permanent measurement situations however, the silicon type has the the advantage of giving higher higher sensitivity. These accelerometers use a mass supported on a beam which has the strain gauges attached.(fig.3.3) The strain in the the beam is proportional to the the applied applied force force and and hence hence the acceleration. These types can give good sensitivity sensitivity and a response at zero Hertz, Hertz, with good high frequency response.
TAFE Mechanical Engineering
29
B. McLauchlan TAFE SI 2006
Mass Connector
Cantilever Beam Base
Strain Gages
Figure 3.3 Piezoresistive Accelerometer Accelerometer
They are usually usually larger than than an equivalent equivalent piezo electric type with the exception of some special micro types designed for very high level acceleration measurements. measurements. Servo Accelerometers Accelerometers
These types of accelerometer use a technique of measuring the force required to restore restore a mass mass to its rest rest postion when accelerated.This force is of course, proportional to the acceleration applied to the accelerometer.This accelerometer.This type type of accelerometer accelerometer can be made very very sensitive to low acceleration acceleration levels, with with a frequency frequency response from 0 to up to 500 Hz.
3.1. 3.1.4 4 Optic al Transduc ers
Optical transducers have not been used extensively in general purpose vibration measurement. Recently instruments have been produced that allow relatively easy use of laser interferometer techniques. Although very expensive, expensive, these these methods are extremely powerful for studying vibration of large surfaces or where a noncontact measurement is needed, such as on fast moving machine components.
3.2 3.2 Selectio Selectio n Of A Transducer
With any vibration vibration measurement, measurement, we must have some idea idea of the range of vibration amplitude amplitude and frequency frequency that is to be be measured so that an appropriate transducer can be selected. We should not simply select select a transducer transducer with very high high amplitude and frequency range performance, performance, as the sensitivity small vibration levels may not be adequate. adequate. Frequency response data is needed to select select the transducer and may be quite different for different transducer designs.
TAFE Mechanical Engineering
30
B. McLauchlan TAFE SI 2006
The useable part of the frequency response is on the flat or LINEAR part of the curve and if if used outside outside this range, range, the results given will be incorrect due to change of sensitivity. Care should also be taken not to expose very sensitive transducers to shock as they may be damaged. This includes transport in vehicles to the measurement measurement site. The mass of the transducer is also important.Recall important.Recall that that the the natural frequency of a vibrating system is related related to spring constant and mass mass in the system. system. Adding a significant mass to the system will change the systems' vibrational character. The transducer mass must thus be very small compared to the system. The type of environment environment should also be considered when choosing the transducer.The temperature range, moisture level, dust, possibility of impact impact etc. etc. should should all be taken into account. For very difficult environments or permanent mounting in industrial situations, special special ruggedised ruggedised types of transducer transducer are available. available.
3.3 3.3 Transduc Transduc er Mounti ng
A vibration transducer transducer will measure measure ALL the vibration vibration that occurs at the measuring point. This means that the mounting of the transducer must not provide additional vibration to that being being measured. Mostly this means that the transducer should be connected well to the item item being measured measured and any brackets used used for mounting should be very stiff.
TAFE Mechanical Engineering
31
B. McLauchlan TAFE SI 2006
Piezo-electric transducer attachment (Pt 1 courtesy Bruel & Kjaer)
TAFE Mechanical Engineering
32
B. McLauchlan TAFE SI 2006
Piezo-electric transducer attachment (Pt 2 courtesy Bruel & Kjaer)
TAFE Mechanical Engineering
33
B. McLauchlan TAFE SI 2006
3.4 3.4 Use Of Condit ioni ng Ampl ifi ers
Many of the transducers transducers for vibration vibration measuremnt measuremnt require the use of a CONDITIONING AMPLIFIER.This is an electronic device that : • • • •
amplifies the small signal from the transducer to a more useful level and range may provide power supply to the transducer allows the measured signal to be recorded in other instruments. ensure that the signal from the transducer does not overload the recording devices
A conditioning conditioning amplifier is not essential essential for some some transducers, but but is recommended for all vibration measurement to ensure consistent results. The conditioning amplifier is essential for piezo electric transducers, due due to the very small signal level level generated by these devices. Some conditioning conditioning amplifiers amplifiers also contain contain the integration circuits needed to convert acceleration signals to either velocity or displacement. Whatever conditioning conditioning is applied it must must always be remembered remembered to isolate, electrically, the transducer from the machine being being measured when mains electrical supply supply is used. This is to prevent electrical noise pickup by the earth connections. (called ground loops)
Tra Transd sdu ucer cer
Con Conditioning Amplifier
Meter or Other Measuring Device
Figure 3.4 Conditioning Amplifier and Transducer
TAFE Mechanical Engineering
34
B. McLauchlan TAFE SI 2006
3.5 3.5 Calibratio n
In any measuring system the dimensions measured must be assured to be correct. This is especially true where where the the system is measuring complex data such as random vibration, as the data is not easily determined determined to be correct by inspection. Calibration Calibration is the term given to the the process of of comparing the measuring system to a reference standard measurement measurement and determining the systems'response. systems'response. In vibration measuring systems, calibration is able to be carried out in the the field, before measuring measuring data, for most types of transducer. In addition, regular recalibration checks of transducers should be made by the the equipment supplier or the national standards authority. authority. In Australia Australia this authority is the National Measurement Laboratory. 3.5. 3.5.1 1 Method Method s Of Calib Calib ration
Calibration must use a reference source for vibration and a means of determining the value of the reference. a. Vibration exciters exciters - These devices devices range from hand held size size to very large structural testing devices. Some devices devices have a fixed, stable stable level of vibration vibration that is suitable as a reference reference for calibration without without further equipment. Other Other devices require require the additional additional use of a reference reference accelerometer accelerometer or other transducer for determining the vibration level. The smaller devices are suitable for smaller smaller piezo electric transducers. The larger devices are only limited by the mass of the transducer and the available force from the exciter. Calibrator Tra Tran nsducer
TAFE Mechanical Engineering
35
B. McLauchlan TAFE SI 2006
b. Displacement Displacement calibration - For For displacement transducers transducers the use of some length length reference may be adequate adequate for calibration. (static only) For example, differential transformers may be calibrated by gauge blocks or precisely machined reference gauges. DVDT
Calibration reference length (guage blocks)
c. Static calibration with gravity gravity - The use use of servo accelerometers, accelerometers, piezo resistive accelerometers or other types of transducer with a response at at zero Hz may allow allow the calibration to be done by tilting in the earths' gravitational field.
Accel Ac celerom eromete eter Angle to provide desired static acceleration due to gravity
θ
acceleration= acceleration= 9.81 x sin
θ
TAFE Mechanical Engineering
36
B. McLauchlan TAFE SI 2006
d. Low frequency frequency pendulum - A pendulum may be used to oscillate an accelerometer accelerometer in the earths' earths' gravity to give give low frequency frequency calibration. Pendulum
Accelerometer
e. Centrifuge - An accelerometer accelerometer may be placed placed in a centrifuge to allow very high accelerations accelerations to be developed. Centrifuge
Accel Ac celerom eromete eter
TAFE Mechanical Engineering
37
B. McLauchlan TAFE SI 2006
Many of the calibration calibration systems described above above are not suitable for field work. Thus reliance must be placed on the sensitivity sensitivity of the transducer ( eg volts/g , mV/mm , mV/m/sec) and if this is the case a calibration of the voltages in the system must be made to give an accurate reference. This can be done using the internal calibration on some conditioning amplifiers amplifiers or a precision precision voltage reference source. Whenever possible, the whole vibration system should be calibrated. That is, when the transducer is recieving the the calibration level, the amplifier and recording devices should also be operated to record the level level right through the the system. This tends to prevent prevent errors in calculation calculation of system system performance performance as the data recorded recorded can be compared to the recorded reference signal. 3.6 3.6 System Erro rs
Any measurement system has an error associated with that measurement. measurement. It is essential essential that some some consideration of the the level of error error of measurement measurement be made. The frequently frequently used used estimate estimate is that of of the method of expected error. This is a value that can be expected for for the ordinary circumstances. circumstances. It is expressed expressed as:
Error = e21 + e22 + e23 +......+ e2n the en are the errors for each part of the measurement (ie each instrument )
For example, consider the following system: a. transducer error +/- 1% b. conditioning amplifier error +/- 1.5% c. tape recorder error +/- 3% d. frequency analyser error +/- 0.4%
Error = 12 + 1.52 + 32 + 0.42 = +/- 3.5 % While this may appear to be a large error, it is typical of most field measurements measurements which are of the order of +/- 5% accuracy. Note that this is not the worst worst case error which which can be as much as 1 + 1.5 +3 + 0.4 = +/- 5.9 % for the example above. This is the error that would occur if the worst error occurred in each instrument at the same time. time. This process process is also only considering considering system TAFE Mechanical Engineering
38
B. McLauchlan TAFE SI 2006
errors, not errors of use of the equipment. Incorrect use, poor calibration or malfunctioning malfunctioning equipment equipment can give unpredictable errors. 3.7 Measur Measur ement Of Shock
Comments about shock measurement have been left to this section as this area is particularly sensitive sensitive to the concern of errors and calibration. Transducers that are to measure shock shock must be carefully constructed to give a sensitivity sensitivity that is in the direction direction of the measurement measurement axis and no other. For example, some some types ofgeneral purpose accelerometers accelerometers are adequate for general measurement measurement but under shock conditions they may exhibit sensitivity in other other directions leading to false false results. results. It is preferable that that transducers for shock measurement measurement be calibrated at the levels levels of of shock shock to be measured. measured. This will ensure a reasonable reasonable confidence in the transducer performance. At the same time the the conditioning amplifier should be considered considered as as this must must give a rapid rise time to follow the impulse or shock data. The tape recorder or or data analyser also also must be "fast "fast enough" to record record the data reliably. Test them all at calibration if possible. Calibration can be done using a falling pendulum pendulum which collides with a barrier. barrier. This is a specialised specialised area and assistance should should be sought to ensure accurate results. 3.8 Data Recor Recordi ding ng
Vibration data may make use of the following means of data recording: • • • • •
chart recorders tape recorders continuous analysis digital recorders computers
3.8.1 3.8.1 Recor Recordi ding ng On Paper Chart
a.Pen Recorders Recorders these may be used to record record the amplitude variations with with time so that these can be studied studied manuallly. manuallly. They can't be used for signals that change much more rapidly than 200 Hz. They are useful useful to study study variation in level with time, time, peak levels and decay rates in buildings. b.Printers - some printers can make a chart like the pen recorders. More frequently they are used to give a permanent record of vibration levels at various times times during a measurement. measurement. Useful for long term studies studies to give hard copy that can can be plotted later. later. TAFE Mechanical Engineering
39
B. McLauchlan TAFE SI 2006
c.LCD Chart Recorders - able to take high speed recordings up to about 10 kHz, these chart recorders are often built as data loggers with extensive hard drive or CD memory. 3.8. 3.8.2 2 Conti Conti nuou s Analysi s
Some instruments take in and analyse data continuously to provide an overall assessment assessment of vibration vibration over a period period of time. Data is often processed or “weighted” by frequency to allow evaluation over a specific range range of frequencies frequencies and excluding excluding others. This type of analysis is often chosen to evaluate the effects of vibration on humans. 3.8.3 3.8.3 Tape Tape Recor ding di ng
The tape recorder is a very valuable instrument for vibration measurements. measurements. There are a number of of ways of making tape recordings. The performance of the different methods is affected always by tape speed. speed. For higher tape speeds, a higher higher frequency response is possible. a. Direct Recording - Direct recording (DR) the most common type of acoustic recording method. method. A frequency range of 20 to 15 kHz kHz is typical, but higher maximum frequency is possible depending on tape speed. Data must be replayed at the recorded recorded speed speed to give correct frequency information. b. FM Recording - instrumentation tape recorders allow FM (frequency modulation modulation ) recording. recording. The frequency range range begins at 0 Hz and extends extends to a limit controlled controlled by tape speed. speed. For the same tape speed the the upper limit of FM FM is less than DR. DR. FM is generally generally more accurate than DR and is able to replay data at any tape speed without loss of relative frequency data. This allows for example, detailed analysis of fast changing data by slowing down the tape speed. speed. FM requires about about 4 times more tape than DR to accomodate the same data. (because of the frequency range limits) c.Digital Recording - Digital recording uses conversion of data to a digital code which is then stored stored on tape. The coding of this method method makes it extremely accurate. accurate. New technology technology is making making digital recording available in compact devices that makes it very useful for vibration recording. recording. Digital recording recording requires more tape than FM for the same same data in a ratio about about 2:3. Being used more extensively as new equipment enters the market, especially in the DAT format with special input electronics. electronics. This type of recorder recorder TAFE Mechanical Engineering
40
B. McLauchlan TAFE SI 2006
allows direct input to computer via a digital output port. This saves a digitising process which is otherwise needed for computer data processing.
3.8.4 Digital Memory
By coding the data into digits, it may be stored in an electronic memory of the type used in computers. Devices such as event recorders and and some data loggers loggers use this method. This technique is usually only used used for relatively relatively short bursts of of data such as explosions due to the limits of storage of the memory. 3.8.5 Computers
Computers have been used for many years for data analysis. Special input electronics modules have been available for multichannel measurement and analysis. In recent years, the development of high quality sound cards for PC and laptops have provided a relatively low cost data entry system. 3.8.6 Calibration
Recording devices must be calibrated so that the recorded values can be interpreted interpreted later. later. The most direct and simple way to to calibrate is to record the transducer transducer calibration. calibration. This gives a reference level on the recording device. CALIBRATION is essential for confidence in measurement
TAFE Mechanical Engineering
41
B. McLauchlan TAFE SI 2006
3.9 3.9 Data Data Analysis Instr umentatio n
The use of correct instrumentation for data analysis will allow thorough and meaningful results from vibration measurement. measurement. The types of possible possible data data analysis analysis has been discussed. The type of equipment needed to carry out these analyses will now be described. 3.9.1 Vibration Meter
A very common common and simple means means of measuring measuring vibration is to use a vibration vibration meter. meter. This type of device device gives gives an overall reading of of the vibration level, usually an RMS RMS value. value. The vibration meter may include signal signal conditioning and integrating sections sections so that an accelerometer can be used for measuring acceleration, velocity or displacement. This type of instrument may also include weighting curves that may be used used for the assessment assessment of particular particular types of vibration such as machinery or human comfort. 3.9.2 Weighting Curves
As with acoustic acoustic measurement, measurement, the use of weighting weighting curves is also common in vibration vibration analysis. The weighting curve can be a filter or it can be produced by numerically adjusting frequency frequency data that is produced produced by an FFT analyser. Weighting curves are used used primarily in vibration vibration analysis for the assessment assessment of human effects effects of vibration. vibration. The numerical numerical adjustment of data data referred referred to above above is usually performed on a computer. 3.9.3 Frequency Analysers
Much use is made in vibration analysis analysis of frequency frequency analysers. The most commonly used analyser is a constant bandwidth FFT (Fast Fourier Transform) instrument. While it is possible to utilise constant percentage bandwidth instruments such as one-third octave analysers, as used in acoustic analysis, these instruments generally cannot provide the detail needed at lower frequencies for machine vibration analysis. It is essential in most measurements measurements of vibration that the frequency can be determined determined with an accuracy accuracy that can discriminate between between the different parts that are causing vibration and this is easily achieved with the FFT analyser. FFT analysers are often implemented as hardware or firmware units but may also be implemented as software applications in PCs or laptops.
TAFE Mechanical Engineering
42
B. McLauchlan TAFE SI 2006
Vibration Isolation 4.1 4.1 Machine Vibrati on
All machinery has has some vibration. vibration. This fact has already already been used to advantage in machine condition monitoring. monitoring. In many cases cases however we wish to either isolate the machine vibration from other equipment or from people or isolate the equipment from vibration. As we have seen already, the vibration of a spring mass system can be expressed in the form of a frequency response curve. (see figure 4.1).
4.1.2 4.1.2 Degr Degrees ees Of Freedom
The curve in figure 4.1 is the response to forced vibration of a "single degree degree of freedom " system. Such a system system has motion that that is restricted to one one direction of displacement. displacement. If the possible axes axes of displacement displacement are considered considered for three dimensions, dimensions, (figure 4.2)
Figure 4.2 Position In Three Dimensions
it can be seen that for a general three dimensional position in space of a single rigid body, that six degrees of freedom are possible. ( ie six possible directions of displacement) The single degree of freedom system then has only one possible direction of displacement which may be either a translational or rotational displacement. displacement. Very few real machines machines are single single degree of of freedom systems. Most are composed composed of many many parts with connections connections of
TAFE Mechanical Engineering
43
B. McLauchlan TAFE SI 2006
varying rigidity. This greatly increases the complexity complexity of the analysis of the machine and its' vibration. Response to Forced Vibration Am pl if ic ati on Rati o 10.00
0.05 0
0.1 0.2 0.5 1.00
1.0
Damping Ratio 1.0
0.10
0.5
0.2
0.1 0.05 0
0.01 0.1
1
10
Frequency Ratio
Figure 4.1 Frequency Response Curve One Degree Of Freedom System
For instance, many vehicle suspension systems are designed considering all the degrees of of freedom possible. (eg motor motor cars, trains) This may require analysis of over 20 degrees of freedom ! This type of analysis can only be reasonably achieved by using computer programs called simulations that solve the mathematical models of of the system system continuously continuously in time. Fortunately, for many purposes use of a single degree of freedom system as an APPROXIMATION to the real system is possible. In this course we TAFE Mechanical Engineering
44
B. McLauchlan TAFE SI 2006
will only deal with single degree degree of freedom freedom systems. It is essential essential however to be aware of the limitation of this approximation when designing vibration isolation for machines. 4.1. 4.1.3 3 The Respon Respon se Curve And Transmissi bli ty
The response response curve shown in figure 4.1 has has two axes. axes. The horizontal axis is the ratio between the natural frequency and the applied ( "forcing ") frequency. The vertical axis is labelled labelled TRANSMISSIBILITY. We have used used this axis to determine either either force ratio or displacement displacement ratio for the vibrating systems. The term TRANSMISSIBILITY TRANSMISSIBILITY refers to the ratio of transmitted force or displacement to that applied to the system. (see figure 4.3) As an example, we may consider the reduction in force to the foundation of a machine which has isolators providing a ratio of forced to natural frequency of 4. This gives a TRANSMISSIBILITY of 0.04 (vertical axis, zero damping). This means that force caused by the vibration of the machine when operating (ie at the forcing frequency) will be reduced to 0.04 of the original at the machine foundation or base. The transmissibility is 0.04 or a (1 - 0.04) x 100 = 96% reduction in force level. The transmissibility is a description of the quality of performance of a vibration isolation system and may be applied as a design standard. It may describe either force or or displacement displacement reduction of the system. Although we have have only calculated calculated single degree degree of freedom examples, transmissiblity transmissiblity may may be applied to any system. system. An alternative means of expressing this requirement is the ISOLATION. The isolation value is frequently used on data sheets for commercial vibration control products. Isolation is a measure measure of the reduction of vibration and is expressed as a percentage. The calculation above for Transmissibility = 0.04 showed that this was a 96% reduction in vibration level. The 96% is the isolation. This leads to the relationships: Isolation % = (1- Transmissibility) x100 Transmissibility = (1- Isolation) (note: use the decimal form of percentage to make this formula work; eg 96% =0.96)
TAFE Mechanical Engineering
45
B. McLauchlan TAFE SI 2006
Force on support G
Input displacement displacement Y
m
m
Input exciting force F
Displacement of Mass X
T = G/F
T= X/Y
figure 4.3 Showing Transmissibility Transmissibility for force and displacement
4.2 4.2 Static Deflecti Deflecti on
When calculating the natural frequency of a system, the following formula is used:
ω =
k m
With any system the spring constant k must be determined to suit the above formula and the transmissiblility required.
TAFE Mechanical Engineering
46
B. McLauchlan TAFE SI 2006
Consider the spring constant: F= kx
where
k = spring constant, N/m F = force , N x = displacement , m
If a machine is lowered onto an isolation system, the springs will deflect from their unloaded position by an amount proportional to the mass of the machine. This is called called the static deflection. If the static deflection is known we can calculate the spring constant. We thus have, using the above equation;
F k= x so,
mg k= xstatic If this information is substituted in the equation for natural frequency we have:
mg mxstatic
ω = or
ω =
g x
We thus have another way of expressing the natural frequency of a system in terms terms only of the static static deflection. deflection. How is this useful useful ? For a required transmissibility, say 0.1, we can determine the required frequency ratio to be about 3.4 (figure 4.1) By knowing the forcing frequency we determine the required natural frequency.
ωnatural =ωforcing / 3.4 TAFE Mechanical Engineering
47
B. McLauchlan TAFE SI 2006
We may now determine the required static deflection directly from the equation equation developed developed above. The suppliers suppliers of vibration vibration isolators isolators often supply information in this form (static deflection and mass) so that this simple relationship can be used for design.
4.3 Center Of Gravity
When machinery is being installed with vibration isolators it is often necessary to consider the position of the center of gravity of the machine. This is the position position where all the mass of the machine machine can be considered to act through a single point giving the same static force. If the center of gravity is known, vibration isolators can be positioned at equal displacements from this point to ensure equal loading. Equal loading on each isolator is preferable as this means that all isolators are of the same same type. This prevents prevents confusion confusion during maintenance maintenance and minimises minimises spare parts stock. The center of gravity is calculated in the conventional method of mechanics using moments about an arbitrary point. It is preferable to mount the isolators vertically in the plane of the centre of gravity. gravity. This will prevent prevent some possible possible additional rocking vibration. This arrangement is not always practicable and is usually reserved for machines that are very large or that have a particularly difficult vibration problem. It should should be seriously considered also in in the case of a machine that is very tall compared to its width. These situations are illustrated in figure 4.3.
TAFE Mechanical Engineering
48
B. McLauchlan TAFE SI 2006
a) conventional mounting
Centre of Gravity
b) mounting in plane of center of gravity Figure 4.3 Center Of Gravity And Mounting Of Isolators
4.3. 4.3.1 1 Locatio n Of Isol ators
We have already observed that the isolators should be mounted so as to have equal vertical vertical static force. force. There are a number of other practical concerns regarding the positioning of isolators so that they operate as designed.
a)Horizontal spacing: In figure 4.4 a) the isolators are shown positioned at equal spacing from the center of gravity however, the isolators are also very close together. This could could cause problems of rocking rocking vibration. It is thus preferable to mount the isolators as far apart as is practicable.
TAFE Mechanical Engineering
49
B. McLauchlan TAFE SI 2006
b)Lateral loading: If the isolators are to operate as desired it must be ensured that the required required spring spring constant constant is achieved. It is possible that the arrangement of mechanical drives or other connections to the machine will add stiffening to the spring constant of the isolators. Remember that a decrease in the spring constant will increase the isolation and so an increase in the spring constant will DECREASE the isolation. Careful attention to the design will ensure that this problem does not arise. Figure 4.5 a) shows examples of designs that interfere with the operation of the isolators. Methods of improving improving the the design design are shown in figure 4.4 b).
a) close mounting (unsatisfactory) (unsatisfactory)
b) far apart mounting (desirable)
Figure 4.4 Position Of Isolators
TAFE Mechanical Engineering
50
B. McLauchlan TAFE SI 2006
a) external loading on isolators (unsatisfactory) (unsatisfactory)
b) correct design to remove isolator side loads Figure 4.5 Design Of Isolator Installation
c) Connection of pipes electrical etc. In a manner similar to that described in part b), the stiffness may be effected by pipework or other connections to a machine that is fitted with vibration isolators. Because this is not always a serious reduction in spring constant, these items items are often ignored. ignored. The additional problem here is that the vibration may be transmitted along these connections, causing excessive noise and potenially excessive stresses stresses that could lead to failure of parts. This is illustrated in figure 4.6 a) where a number of unsatisfactory arrangements are shown. In 4.6 b) alternative arrangements are shown. Often these alternatives also provide allowance for thermal expansion of machines and certainly will reduce the incidence of failure in connections. connections.
TAFE Mechanical Engineering
51
B. McLauchlan TAFE SI 2006
a) direct connection to machinery (unsatisfactory)
b) connections that isolate vibration
Figure 4.6 Connections To Vibrating Machines
d) Spring Constant with Multiple Isolators In all the analysis, we have assumed a spring / mass system with a specific spring constant but have only referred to one spring. Most realistic isolation designs for machines require 4 or more springs. How do we relate the spring constant from the analysis to the practical application? Springs can be connected in either series or parallel as shown in figure 4.7. The same results apply to either tension or compression springs.
TAFE Mechanical Engineering
52
B. McLauchlan TAFE SI 2006
Springs in Series Series o r Parall Parallel el
Series
Parallel
K K
K
K
K
K
K K total = K + K + K + K K
K total t otal = 1 / (1/ (1/K K + 1/K + 1/K + 1/K)
If K = 100 100 N/m N/m fo r all spring s: K total t otal (Series) (Series) = 25 25 N/m N/m K total t otal (Paralle (Parallel) l) = 400 400 N/m N/m Figure 4.7 Spring Constant for Multiple Springs
Figure 4.7 shows that springs in series decrease the spring rate whereas the same springs in parallel increase the spring rate (compared to the rate of a single spring) When supporting a machine with multiple springs the spring constant determined from the analysis must be divided by the number of springs that will be used for support. The new spring constant determined will be used to select the actual springs used. For example, the required spring rate for isolation of machine vibration might be 50kN/m. If 4 springs are to be used for supporting the machine, then each spring will require a spring constant of 50/4 =12.5 kN/m.
TAFE Mechanical Engineering
53
B. McLauchlan TAFE SI 2006
4.4 4.4 Types Of Isol ators 4.4.1 Materials
Many materials materials may be used for isolation of of vibration. A list of the common types follows:
Material
Form that it is used
felt
felt mat felt composites
cork
cork blocks cork composites
composi posite materi teria als
rubbe rubber with with non - metal tallic reinforcement Neoprene and cork
rubbers
natural natural rubber synthetic rubbers
wire mesh metal tal spri spring ng
coil coil spri spring ng leaf springs
air
air bellows
Each material has an area of specific application related to the available static deflection. This means that selection in some applications may be limited to one type of of isolator. isolator. Figure 4.8 shows the typical range of application for the types of material.
TAFE Mechanical Engineering
54
B. McLauchlan TAFE SI 2006
Deflection
Natural Frequency
mm
Isolator
Hz
250
1.0
Air Air
25 Metal Springs 2.5
10 Rubbers
0.25
Cork
0.025
100 Figure 4.8 Areas Of Use Of Isolation Materials
4.4.2 Using Materials
FELT A matrix of textile fibres which which is usually supplied supplied in sheet form. Usually used used for applications where well well balanced machines are expected expected to produce vibrations vibrations at at acoustic frequencies. It is necessary to use a low loading per unit area to prevent settling and loss of isolation. isolation. Often used between a concrete concrete machine base and the foundation or floor. CORK A naturally occurring substance that is processed into convenient shapes for use. use. Cork may be used for high compressive loads at low acoustic frequencies (50 - 60 Hz) More widely used than felt as the engineering properties are more readilly available. Able to be treated against most industrial contamination. RUBBERS These materials offer a wide range of mouldable shapes and properties properties that provide provide isolators isolators for many many applications. applications. Rubber materials have varying resistance to industrial contaminants and the following should be considered: 1 Temperature of operation 2 Ozone 3 Sunlight TAFE Mechanical Engineering
55
B. McLauchlan TAFE SI 2006
4 Liquids eg oils The manufacturers'data should be consulted to ensure adequate life in the particlular environment that is to be considered. METAL SPRINGS Used in the range 3 - 10 Hz these isolators provide the lower lower frequency frequency area of of isolation isolation after the rubbers. rubbers. A wide range of spring types and sizes means that a suitable design is usually able to be achieved and provide good environmental performance. performance. These springs however usually have very low damping and generally require external damping to achieve desired performance. AIR SPRINGS Used for high isolation at low frequency and in some cases where vibration amplitude is very small. The air spring system can provide a constant hieght with varying load while maintaining the required isolation performance. Although more complex and costly than other systems, it is often the only choice for high performance isolation. 4.5 Damping Dampin g
The term damping has been mentioned previously and must be considered in all isolation design. Damping refers refers to that part of a vibrating system that provides loss of vibration energy, either intentionally or unintenionally. Damping ensures that vibration does not continue indefinitely after excitation of the system occurs. Isolation materials materials have a degree degree of internal internal damping. Some values are listed in table 4.1 Material steel rubbers air damping felt/cork
Approximate damping ratio 0.005 0.05 0.17 0.06
Table 4.1 Damping Ratios Of Some Materials Materials
The effect of damping appears in figure 4.1 as the damping ratio. This is the ratio of actual damping to critical damping (see sect. 1 and 2).
TAFE Mechanical Engineering
56
B. McLauchlan TAFE SI 2006
It can be seen that the isolation effect reduces as damping increases so so why have damping damping ? Damping provides provides a limit to the oscillations at resonance. resonance. For many machines machines operation operation at resonance will not occur but may be experienced at start up or during run down. down. Other machines may not be able to to completely avoid resonant operation and thus damping must keep oscillations at an acceptable acceptable level. Damping also effects effects the natural natural frequency of the system. The natural natural frequency frequency of of the system is altered altered by :
f nd = f n 1− ξ 2 where fnd= natural frequency with damping fn= natural frequency ξ = damping ratio
In many cases the effect is small, for example with rubber isolators with a damping ratio of 0.05 the change in natural frequency is less 0.2 %.
4.6 Real Real Isolati Iso lati on
Actual isolation may not be exactly as predicted by the one degree of freedom model. The reductions reductions at acoustic frequencies may be less than than that in the transmissiblity graph. This comes comes from the simplified mathematics mathematics used used for this system. In a real system the mass and stiffness of the support structure are important in achieving reasonable performance. 4.6. 4.6.1 1 Suppo Suppo rt Stru ctur e
As a guide, the mass of the supporting structure should be at least 1000 times greater than the mass that is vibrating. The foundation stiffness is also of concern because it acts as another spring in the system. The natural natural frequency fn of the spring mass system of the isolated machine should be lower than the lowest natural frequency of the foundation structure. The natural frequency of the foundation should also not be an exact multiple of fn. To assist in this it is better to have as low stiffness isolator as possible when the foundation is suspected of some significant flexibility such as a suspended floor. An example of this is a machine operating at 1500 rpm could be isolated on a basement floor of a building with 95% isolation by a static deflection of 8.6 mm. TAFE Mechanical Engineering
57
B. McLauchlan TAFE SI 2006
For suspended floors such values as: 10 m span 12 m span 15 m span
10 mm static deflection 10.7 mm " " 11.2 mm " "
are recommended by a machine supplier. 4.6.2 Mounting Frame
Any frame that is used to mount a vibrating machine should be designed with maximum feasible stiffness to prevent amplification of vibration. 4.6. 4.6.3 3 Lateral Stabilit y
When designing any vibration isolation installations it is clear that it is desireable to have have a relatively relatively large static deflection. This provides minimum transmissibility. An isolator with low stiffness (ie large static deflection) may also have a low lateral stiffness. This may affect other modes of vibration but also may cause problems with excessive motion of the isolated machine. This type of problem is usually more significant if the machinery is in motion as in a vehicle. Acceleration Acceleration or retardation retardation of the vehicle vehicle will mean a large longitudinal or lateral force must be transmitted by the vibration isolators. The large force and and /or displacement resulting could damage the isolators or even disconnect the machine from its mountings. To overcome this motion is often limited by safety stops or resilient bumpers. This problem also often limits the practical spring constants usable and hence place a limit on the realisable maximum performance of isolators. Thus, even though it is theoretically possible to achieve a reduction of of 99. 99% of the vibration it may may not be practical due to the very low lateral spring constant leading to instability.
4.7 4.7 Isolati Isolati on Of Equipm ent From Base Vibr Vibr ations
In most of the above examples we have been discussing the isolation of a vibrating machine from the structure that is carrying it. In some cases, such as the use use of delicate equipment on a vibrating machine, the isolation is to minimise the vibration recieved by this equipment. Even with low transmissiblity isolation, damage may may occur to the sensitive equipment. equipment. This is because because of of the resonant effect that we have already studied. Low level TAFE Mechanical Engineering
58
B. McLauchlan TAFE SI 2006
vibrations that are transmitted can be amplified by a resonance in the equipment. To avoid this problem we must know what the resonances resonances are. We have seen already that most real systems are multi - degree of freedom systems. The analysis analysis for these systems systems is complex but may often be achieved using finite element methods on a computer. We can also experimentally study the response of the system to vibration by placing the delicate equipment on a "shaker" like those used for calibration but with the ability to provide a variable frequency and level. Resonances of equipment can then be observed by accelerometers or non-contact measurement using laser interferometry. interferometry.
4.8 4.8 Summary Summary of Isolator Consi derations
For practical design of isolators then we should consider: the required transmissibility b) even spacing from the center of gravity c) positioning in the plane of the center of gravity d) positioning of equipment to avoid loss of isolator performance e) minimising vibration transmission through pipes etc. f) the type of isolator material and its environment g) damping of the isolator and need for additional damping h) effect of the isolator at higher frequencies i) support stiffness and mass j) lateral stability of the isolators isolators
TAFE Mechanical Engineering
59
B. McLauchlan TAFE SI 2006
Vibration - Human Human Effects 5.1 The Human Bo dy
The human body is composed of soft tissue and a hard skeleton with connections connections of firmer muscle tissue. tissue. This structure structure has then basically a rigid frame with masses hung on resilient (springy) mountings. This means that the human body can be considered as a complex of spring mass systems that will respond to vibration. There are two major areas of concern for the human effects of vibration: a.whole - body vibration (vibration applied applied to the entire body) b.hand - arm arm vibration vibration (vibration applied in a limited area of the the hand/arm as when using vibrating tools) 5.2 5.2 Whol Whol e Body Vibrati on
Interest in the response of the human body to vibration began with the transport transport industries. Concern with passenger passenger comfort in rail vehicles, ships, aircraft and limits for military vehicles each generated research into this area. The research has shown many similarities but, as yet little correlation between vibration levels and injury has been established. The vibration criteria criteria are thus thus not as clearly clearly defined in requirement as for instance instance noise exposure. In noise exposure, we were concerned with damage damage to the human ear. ear. What are are the effects on the human body from vibration ? 5.2.1 5.2.1 A Bod y Model
The human body can be modelled as a series of spring mass systems made up of muscle and tissue as spring elements, body organs as masses and connected via the skeleton. The different spring - mass systems represent the different parts of the body, for example, the internal organs are suspended by tissues forming the spring mass system. Each system system will have have a different natural natural frequency. frequency. This means that certain vibrations will make different parts oscillate.
TAFE Mechanical Engineering
60
B. McLauchlan TAFE SI 2006
Figure 5.1 The Human Body as a Spring – Mass System (Coerman et al)
5.3 5.3 Testi Testi ng Human Human Vibratio n Sensit Sensit ivi ty
Most of the testing for human vibration sensitivity has been done by subjecting volunteers to varying sinusoidal vibration and recording their response. This method does not completely establish the response of the body to a complex vibration, such as multiple axis vibration, but does give an indication of trends. This means that the effects of random vibration, for instance, will not always follow the same sensitivity curves Recent work (1997) has begun to address this problem to get more accurate data..
TAFE Mechanical Engineering
61
B. McLauchlan TAFE SI 2006
5.3. 5.3.1 1 Direction Of Vibratio n
For whole body vibration, the vibration may enter the body while in a standing or seated position. The vibration may be horizontal, vertical or lateral. The human body has differing sensitivity sensitivity in each each of these these directions directions due due to differing stiffness in each plane. This means that muscle effort is required to restrain the body parts, leading to fatigue. The vibration may even interfere with the organs' function, such as distortion of vision by vibration of the eye. Excessive levels of vibration can lead to tissue damage or illness. For example, oscillations from earth moving machinery may cause spinal injury. 5.4 5.4 Vibr Vibr ation Crit eria
Due to the differing uses for vibration criteria they been frequently considered in separate categories of comfort limits and exposure limits.
5.4. 5.4.1 1 Comf Comf ort L imi ts
These limits are established to provide passenger comfort in the transport of humans. Comfort limits are usually expressed in terms of time of exposure. exposure. That is, a lesser lesser comfort level is acceptable for for short duration trips and for longer trips lower levels of vibration must be provided. provided. This is to ensure ensure that the passenger will will not be excessively fatigued at the end of the journey. Each mode of of transport has has differing vibration vibration source source mechanisms. mechanisms. This leads to differing comfort criteria. For example, example, ships must consider consider very low frequency vibration which does not occur in most other forms of transport. Aircraft have high frequency vibrations that are more irregular than other transport. 5.4. 5.4.2 2 Exposure Li mit s
These limits have been set to indicate the maximium levels that humans can can be exposed exposed to in industrial situations. In using these limits, it should be noted that the fatigue level will be higher and so task performance will reduce. If these limits are to be used, they should be considered as infrequent exposures as in an emergency situation. 5.4 The ISO Standard
The vibration limits for human exposure have been expressed as an ISO standard. standard. This standard has been used as the basis for the Australian Standard (AS2670) (AS2670) Although this standard standard is based on on TAFE Mechanical Engineering
62
B. McLauchlan TAFE SI 2006
pure sinusoidal vibration tests on subjects, it has become acceptable to use this in the absence of more precise information. It is a good guide for general industrial applications and as a start point for establishing special purpose vibration standards. Weighting curves are used to give a single value measure of comfort levels. levels. The Australian standard has also included included the very very low frequency extension to the ISO standard that covers the motion sickness region. Modified criteria are used as guidelines for exposure limits to protect against ill health or injury.
5.5 Instrumentation
Considering the frequency range of the human sensitivity to whole body vibration, we can determine the frequency range and sensitivity of the required measuring instruments. The standard shows that a maximum level of 1.0 g will be applicable for most most measurements. measurements. The frequency frequency range will be between 50 and 100 Hz, depending on the likely vibration source spectrum. For example, example, aircraft aircraft measurements measurements will require require up to 100 Hz, while motor vehicle measurements will be adequately covered by a 50 Hz range. If motion sickness sickness measurements measurements are to be made, made, the low frequency frequency range, range, 0.1 to 1.0 Hz, must also also be considered. considered. For these types of measurement, the use of servo accelerometer or piezo resistive accelerometer types is common. The piezo electric types sometimes cannot provide the low frequency sensitivity, unless specially selected. The measurement of vibration should be made at the point of entry of the vibration to the the human body. body. That is, if the subject is seated, the vibration limits apply at the seat surface not the floor that the seat is attached to. This is because the seat itself may amplify the vibration that comes from the floor. The low frequency of the vibration data means that only FM tape recorders can be used to record the information. A suitable conditioning amplifier must also be selected. As the measured data data may be either weighted or or unweighted the assessment according to the standard will be in two possible manners:
TAFE Mechanical Engineering
63
B. McLauchlan TAFE SI 2006
i. weighted data compared directly to the AS2670 curves to determine the allowable exposure time ii. unweighted data is first weighted in each frequency band and then compared to the AS2670 curves. In the first case, the RMS value from the instrumentation is directly compared to the curves. The second case may utilise computer calculation to speed the weighting and assessment process. Where vibration is steady, the first method may give the most rapid result. If vibration is unsteady, for for example, random random vibration in a vehicle, an averaging process may be needed to ensure the correct exposure exposure is determined. determined. This may be achieved achieved by measures measures at various levels that are typical of the environment and summing in proportion to to the time exposed exposed at each each level. This is equivalent equivalent to the Leq method used for noise. Alternatively, a sample may be taken over a representative period using an integrating process to determine the total exposure. 5.6 5.6 Hand Hand Ar m Vibr ation
Whole body vibration is frequently able to be maintained at or below fatigue levels so that significant injury is not normally of concern. With hand arm vibration however, there is a real danger of serious and permanent injury. Vibration at high levels applied to the hands while using machinery or tools can cause disease of the blood vessels, vessels, joints and blood circulation circulation system. system. The result is what is called "vibration white finger" or Reynauds' disease. Circulation of the the blood becomes becomes so poor that fingers fingers and hands may turn white and in extreme cases permanent tissue damage or or gangrene may result. The type of machinery machinery that can can cause this type of injury is that producing high levels of vibration and which must be hand hand held held for for long long periods periods of time. time. For example: Chainsaws, chipping hammers, rivetting guns, power grinders, and hammer drills. These types of machines may be found in many industries and are often able to generate very high levels of vibration in human hands and arms. 5.7 5.7 Hand Hand Arm Expos ure Limi ts
TAFE Mechanical Engineering
64
B. McLauchlan TAFE SI 2006
An ISO standard has been developed which forms the basis of the AUSTRALIAN AUSTRALIAN STANDARD. STANDARD. The Australian Standard also includes reccommendations for medical recording of the effects of vibration exposure to the hand arm. arm. This is because because of the relatively limited experience in Australia with this disease. disease. The standard specifies specifies the postition for measuring vibration levels as an axis system related to the human skeleton at the wrist. This is to standardise the level allowed in the measured direction. The standard provides a weighting curve from which allowable exposure can be determined.
TAFE Mechanical Engineering
65
B. McLauchlan TAFE SI 2006
5.8 Instrumentation
The most appropriate instrumentation for this work is an integrating vibration meter meter with the standard weighting curve. curve. This allows the measurement of vibration directly in a weighted RMS value that can be compared to the allowable exposure limits. The placement of the accelerometer to measure this vibration is probably the most difficult part of this type of measurement. The requirement is to measure at the "3rd metacarpal" (ie knuckle) of the exposed exposed hand. To achieve achieve this this a special mounting for the accelerometer accelerometer is required. required. Many researchers researchers have made their own mountings but now commercial items such as that by Bruel and Kjaer are available. This type of measurement usually requires an miniature accelerometer so that the instrumentation is not too bulky so that it interferes with the operation of the machine being being measured. measured. In use the three axes of vibration must be measured by successive measurements measurements after repositioning the accelerometer. 5.9 5.9 Actio n To Minimis e Risk Risk
The incidence of "vibration white finger" in Australia is presently less than other areas as the climate is more favourable in this country. The disease apparently has more rapid onset with cold extremities. That is, where workers are exposed to lower temperature ranges while operating the equipment. This does not mean that workers are safe in Australia, only that they may require more time before the injury appears. appears. To protect operators then measurements measurements must must be made so that doseage doseage will be limited. The coupling of vibration to the hand is also important so that the wearing of glove should be ecouraged wherever possible. This is especially important where low temperatures are experienced. 5.10 Building Vibration
The vibration experienced in buildings is not generally regarded as dangerous to health. health. There is however however some concern concern for discomfort discomfort of humans in buildings, especially the taller ones that are subject to wind sway. The ISO standard provides guidelines for acceptable vibration levels for these situations.
TAFE Mechanical Engineering
66
B. McLauchlan TAFE SI 2006
Balancing Of Machinery 6.1 6.1 Reasons Reasons For B alancing
Balance refers to the even distribution of mass mass around the axis of rotation. Any variation from this distribution results in imbalance.
Axis of Rotation & centre of gravity aligned
Axis of Rotation & centre of gravity misaligned (not balanced)
Figure 6.1 Distribution Of Mass Of A Rotating Machine
For any rotating machinery, any out of balance will cause a rotating force proportional to the amount of unbalance. This force will cause vibration that can lead to excessive wear and/or failure of the machine. Unbalance is probably the most common source of vibration in rotating machinery. For any machine except those that rotate at very low speeds, balancing must be considered part of manufacture and maintenance. 6.2 Unbalanc e For Force ce
The force due to unbalance can be expressed by :
F = mrω 2 where F represents the rotating force due to imbalance. The other factors are m , the mass at radius r that is unbalanced , and w is the angular velocity. Note that the unbalance force increases in proportion to m or r but increases as the square of ω. Thus as operating speeds are increased the need for balancing becomes rapidly more important.
TAFE Mechanical Engineering
67
B. McLauchlan TAFE SI 2006
Rotating Force due to unbalance
Figure 6.2 Force due to unbalance
Notice that the force is rotating at the shaft speed so the frequency of vibration due to unbalance is expected to be: Frequency of unbalance (Hz) = RPM of shaft / 60 In the example in figure 6.1 the rotor is represented by a disc. While some machines may be considered to be like this, for example, fans, many machines have rotating parts that have a considerable length. (See figure 6.3) Real rotors may have unbalance in two planes that is of the same mass but exactly 180 degrees out of alignment. Such a rotor is in STATIC balance but will still give an out of balance force at each bearing when run. This will be in the form of a couple formed by the two out of balance forces. Such a rotor is not DYNAMICALLY balanced. Static balance can be achieved by ensuring the rotor does not have a "heavy spot" when rotated at low speed. That is, the the rotor does not stop at any any preferred position when when allowed to turn freely.
2 P lane lane Rotor Rotor
Mult Multi -Plan -P lane e Rotor Rotor
Figure 6.3 Real Machine Rotors TAFE Mechanical Engineering
68
B. McLauchlan TAFE SI 2006
The other alternative is that the out of balance masses will be of differing sizes sizes and at differing angular positions positions and and radii. This is the more more common common situation situation and will cause cause out out of balance forces of differing magnitudes and phase at each bearing. A single single rotor such as that in figure 6.1 is a 1 PLANE balancing problem. The rotors in figure 6.2 are examples of 2 PLANE and MULTI - PLANE balancing problems. In this course we will only discuss solutions to 1 PLANE problems.
It can be seen that for any of these situations, the out of balance force is always always radial and rotates at the shaft running running speed. This is what allows us to detect unbalance by vibration measurements at the bearings.
6.2 Severity Standards
Every real machine will have some amount of imbalance. Balancing of a machine is to ensure that this imbalance is sufficiently small to be tolerable. But what is tolerable tolerable ? The international standard ISO 1940 gives recommended recommended quality grades for for balance of rotors. This standard standard makes use of units of unbalance that are determined by considering the mass of the rotor to be eccentric from the the axis axis of rotation by an amount that causes an equivalent unbalance force. The unbalanced force Fu can be expressed as :
Fu = mrω 2 Where r
=
m
=
unbalanced mass in grammes
radius from axis of rotation of m (in mm)
The equivalent expressed by:
effect
of
displacing
the
rotor
mass
can
be
Fu = Meω 2
TAFE Mechanical Engineering
69
B. McLauchlan TAFE SI 2006
where : M = mass of the rotor in kg e = eccentricity of the rotor from rotation axis From these equations :
Meω 2 = mrω 2 or
e=
mr M
g .mm / kg
This gives the the units referred referred to in ISO 1940. There is some some concern concern in industry however that the balance quality grades were developed some years ago and reflect the need and technology of low to medium speed machines. It has has been been suggested that the the ISO ISO standard be used as a guide to orders of magnitude and attempts made to balance to as high a standard as possible, for a given application. 6.3 BALANCING BA LANCING OF ROTORS ROTORS (Singl e Plane Plane Balanci ng)
In practice, a rotor rotor may be balanced balanced in place with simple simple vibration measurements measurements if it can be assumed assumed to be a single plane rotor rotor such such as a fan. Measurement of at least least vibration vibration level level is required for for balancing. If angular shaft position can also be measured, balancing will be more rapid. The measuring system will be discussed in a later section. 6.3.1 The Four Run Method Of Balancing This method requires only the measurement of vibration at the bearing closest to the rotor to be balanced. The method is as follows: a Install the accelerometer on the bearing b Place three marks at 120 degrees to each other on the rotor and mark them 1 , 2 , 3. c Run the machine machine and read the vibration vibration level, Vi mm/sec. d Attach a trial mass at point 1 e Run the machine machine and read read the vibration level , A1 mm/sec mm/sec f Move the trial mass from point 1 to point 2 g Run the machine and read the vibration level , A2 mm/sec h Move the trial mass from point 2 to point 3 i Run the machine and read the vibration level , A3 mm/sec j Plot the data as circles.
TAFE Mechanical Engineering
70
B. McLauchlan TAFE SI 2006
k From the diagram measure Vf from the center of the first circle to the intersection of the A1 , A2 , A3 circles. l Calculate the magnitude of the balance mass by:
mbalance =
Vf Vi
mtrial
m Place the balance mass at the same radius as that used for the trial mass and in the direction of the vector Vf n Check run the machine to ensure adequate balance
Note : the trial mass can be determined from : Rotor mass m
=
Peak vibration level x
angular velocity
Radius of fixing
or
kg mm/sec m = ------ x r/sec mm 6.3. 6.3.2 2 Balancin Balancin g Using Vibr ation A nd Posit ion Measur Measur ement
This method uses both measurement of bearing vibration and shaft angular position. Instrumentation Instrumentation for this will be discussed seperately. The method method is as follows: follows: a b c d e
Position the accelerometer on the bearing Position the shaft transducer Mark the rotor at 90 degree increments Run the machine and measure the vibration Vi, mm/sec Fix a trial balance weight at 90 degrees against rotation from the angular position of the unbalance vector (use the previous method for an estimate of the balance weight) f Run the machine and meaure the vibration At, mm/sec g Remove the trial weight. h Plot the vector Vi to scale and position i Plot the vector At to scale on this diagram TAFE Mechanical Engineering
71
B. McLauchlan TAFE SI 2006
j Determine the the magnitude of the balance balance weight from the ratio of Vi to At, that is:
Vi m
balance
=
x mtrial At
k Determine the the direction of of mounting from the angle OFB taken in the direction direction against rotation and and from the present position of the trial mass. l Position the calculated balance weight at the same radius used for the trial weight weight m. Run the the machine machine and check check the vibration to ensure adequate balance has been achieved.
6.4 BALANCING BA LANCING OF ROTORS ROTORS (Two Plane Balanci ng)
Two plane balancing requires the determination of mass, angular position and radius for the balance weight at each end of the rotor. This requires requires many more trials than the methods above. Usually this type of rotor is balanced in a commercial balancing machine. 6.5 BALANCING BA LANCING OF OF ROTORS ROTORS (Mult (Mult i - Plane B alanci ng)
The problems of multi - plane balancing are relatively complex and usually require the assistance of someone experienced in this type of work and the use of computer software for the calculations. 6.6 Instrumentation For Balancing
The instrumentation for balancing single plane rotors is no more complex than that used used for other vibration measurements. measurements. In section 6. 3. 1 the only items needed are an accelerometer, accelerometer, a conditioning amplifier and a meter to read vibration level, usually in mm/sec. The instrumentation should be chosen with adequate frequency response to measure at the running speed of the machine to be balanced. At times times an additional filter will be required required to reduce the signal at frequencies other than that of the running speed. In the method described in 6.3.2 the instrumentation as above is used with the addition of some form of angular position sensor. This sensor could be a non - contact proximity probe that is triggered by a key way on the shaft, a strip of reflective reflective material material or other method. From this detector the phase angle of the unbalance vector can be determined. determined. This can be done on an an oscilloscope oscilloscope by TAFE Mechanical Engineering
72
B. McLauchlan TAFE SI 2006
comparing the accelerometer data with the detector pulse position and calculating the phase angle. Alternatively, commercial instruments are available that calculate the phase angle directly directly from the data. In either case the data is used to apply the method described above. For two plane balancing, balancing machines are available as complete units. These use transducers at both bearings simultaneously. simultaneously. The data is reduced reduced electronically electronically to a readout readout that provides magnitude and position data for balancing at each end.
TAFE Mechanical Engineering
73
B. McLauchlan TAFE SI 2006
Vibration Specification 9.1 9.1 When When Is A Specif Specif icatio n Required ?
It is clear that a vibration specification may be included in a general specification that will be used when calling for tenders. tenders. There may also be reasons for vibration specifications specifications within an organisation for example, example, for quality quality control. We should should thus consider consider all these possibilities. The table below lists some possible areas that a specification for vibration may be applied.
Manufacturing : Type Of Vibration Product vibration Product vibration Product vibrationh
Specification For: quality control human body exposure human hand exposure
Example: electric motor helicopter power tools
Maintenance : Type Of Vibration Machine vibration Machine vibration Machine vibration Machine vibration
Specification For: repair quality condition monitoring human body human hand
Example: after overhaul any machine exposure exposure
: Specification Specification For: performance criterion human body exposure
Example: pump quality tractor
Equipment purchase Type Of Vibration Machine vibration Machine vibration purchase Machine vibration
human hand exposure
powertool purchase
Table 9.1 Application Of Specifications
9.2 9.2 Standards Standards For Specif icatio ns
Where possible, the existing standards from SAA, ISO or other sources should be used for specifications.
TAFE Mechanical Engineering
74
B. McLauchlan TAFE SI 2006
9.3 9.3 Specifi Specifi cation Content
In creating a specification it is important that the required vibration levels be specified and that the type and position of instrumentation be included in the the specification specification test procedures. procedures. The standards above provide ranges of values for specified conditions. The standards generally do not provide a specific value for the required conditions or positioning or type of instrumentation. 9.3. 9.3.1 1 Level Specificati on
The level of vibration must be selected by the specification writer to suit the conditions of use of the item item specified. specified. For example, example, the level of allowable vibration for a military vehicle for whole body vibration will be able to be set somewhat higher than that required for an executive limousine. In choosing choosing the allowable level some some consideration should be given to wear and age of components to ensure that the item specified has adequate performance for life between overhauls. This may require additional additional testing of "worn in" prototypes or some other means of predicting future performance. When specifying vibration levels it is important to consider the averaging time over which the measurement is to be taken. Clearly, for a machine operating at constant speed and load, the vibration should should be relatively constant. constant. For a machine subject subject to varying speed or load or both however, the vibration level will vary considerably in time. Averaging of the signal with time may be acceptable for some circumstances circumstances and not others. 9.3 9.3 2 Specif Specif icatio n Of Frequency
Consideration of the frequency content of the vibration must also be made, although this may be controlled using the standard weighting curves in the standards mentioned above. If the standard weighting curves are used these should be specifically mentioned and include the particular means of determining weighted vibration level. This is because the differing ways of determing weighted value may lead to slightly different answers. The means of determining the weighted level are: a. using an electronic weighting curve b. using a frequency analyser and mathematical weighting c. evaluating limits at each frequency individually
TAFE Mechanical Engineering
75
B. McLauchlan TAFE SI 2006
It is usually usually preferable to use a. above however however this means means that if the data is weighted as it is recorded then the unweighted data is not available for further analysis. analysis. For many applications applications then it may be better to record the unweighted data and then process either with a weighting filter or a frequency analyser. The specification of frequency should also consider the range of frequencies to be measured. This should be specified as a frequency band and should be within the specified abilities of the specified instruments. 9.3.3 Instrumentation Specification
The aim here is not to specify a particular brand of instrumentation but to ensure that the ability of the instrumentation system to measure the vibration accurately is ensured. Rather than specify each part of the instrumentation system it is often preferable to simply describe the overall performance of the system. This may still require some extra details for some applications for transducer performance particularly. We should specify the following: • • • • • • • • • • •
required minimum sensitivity in appropriate vibration units expected maximum vibration level frequency range to be measured in Hz overall error in determining vibration level overall error in frequency determination or weighting methods or standards of calibration data recording method data analysis method ownership of data or copies to be supplied method of reporting results special requirements
9.3. 9.3.4 4 Posit Posit ion Of Instr umentati on
The position position of instrumentation instrumentation is extremely important. important. Position usually refers to transducer position only. Small changes in position can make a large difference in the measured data and cause disagreement disagreement over acceptable acceptable performance. performance. Where possible, possible, utilise standard positions and fixing of transducers and fixtures that are of adequate stiffness to ensure accurate measurement. It is preferrable to measure the position of the transducers so that repeat measurements measurements can be made in the same location and any calculation using the vibration data can be carried out correctly.
TAFE Mechanical Engineering
76
B. McLauchlan TAFE SI 2006
9.4 Operating Conditions
It is important that the operating conditions when measuring be specified. Some machines may only require measurements measurements at constant speed and constant load. load. Others may may require a range of speeds and loads to be measured or that run up or run down in speed be measured. Each required condition should be specified and the test test conditions conditions for each each clearly clearly indicated. indicated. This may require additional instrumentation such as tachometers, wattmeters (for load measurement), dynamometers etc. The accuracy of this equipment should also be specified. Operating conditions also may require certain environmental conditions such as temperature to be considered. considered. The specification specification writer should provide test conditions that are appropriate but also those that can be realistically expected to be able to be produced and controlled at the time of test. This will apply particularly to product quality control where vibration measurements measurements are made at the end of a production line. The type of loading and means of loading may dictate the type of testing possible.
TAFE Mechanical Engineering
77
B. McLauchlan TAFE SI 2006
Ap p end i x Relationship of Vibration Amplitude Parameters Velocity can be regarded as the time rate of change of displacement. Using calculus, the first derivative derivative of displacement displacement is velocity as shown. Similarly, we can consider acceleration to be the time rate of change of velocity - and thus the first derivative of velocity OR acceleration is the second derivative of displacement. This can be seen below:
displ displace acement ent
X = A sin( t)
. V=
dx = Aω cos(ω t) dt
velocity
d2x A = 2 = − Aω 2 sin(ω t) dt
acceleration
Mathematical formulation of transmissibility T (or amplification ratio) 2
T =
1+ [2ξ (ω / ω n )]
[1− (ω / ω ) ]
2 2
n
2
+ [2ξ (ω / ω n )]
ξ = damping ratio ωn = natural frequency, rad/s ω = forcing frequency, rad/s
T = transmissibility = Force ratio = displacement ratio Force ratio = Vibration force / force transmitted to structure Displacement ratio = Displacement of vibrating part / displacement of supporting part.
TAFE Mechanical Engineering
78
B. McLauchlan TAFE SI 2006
Vibration Exercises 1. A spring mass system has mass = 50kg, k=56kN/m.What is the natural frequency frequency of this system ? What is the natural natural angular frequency of this system ? (Answer: f = 5.33 Hz, ϖ = 33.5 rad/sec) 2. If a spring mass system has m = 210 kg and natural frequency = 2.2 Hz, what is the spring constant k for this system. (Answer: k = 40 kN/m ) 3. A 1000 kg machine is supported on four springs, which are identical and and carry equal equal proportions proportions of the the machine weight. If the springs deflect 5 mm when the machine is place on them, find: a.the spring constant for this system b.the spring constant for each spring (Answer: a. 1.96 MN/m, b. 490 kN/m)
4.A machine has a normal running running speed of 1500 rpm. It has a total mass of of 390 kg and is supported on four springs springs with a spring constant of 200 200 kN/m each. Find a. the natural frequency b. the forcing frequency c. the ratio of forcing frequency to natural frequency.
(Answer: a. 7.21 Hz, b. 25 Hz, c. 3.47 )
5. For a harmonic vibration, the equation for displacement with time of the vibrating mass is: x = A sin ( ϖ t ) If the frequency for this vibration is 1000 Hz and A = 0.01 mm, find the value of x ( the displacement) when : a. t = 0.0 sec b. t = 0.00025 sec c. t = 0.00050 sec d. t = 0.00075 sec e. t = 0.0010 sec Sketch the curve between these points.
TAFE Mechanical Engineering
79
B. McLauchlan TAFE SI 2006
f. where do the maximum and minimum values occur ? g. what is the magnitude of these values ? (Answer: a. 0, b. 0.01mm, c. 0, d.- 0.01mm, e.0, f. at b and d, g. the max/min max/min values are 0.01 and -0.01 -0.01 = A )
6.Vibration displacement, velocity and acceleration areall related by: x = A sin ( ϖ t ) x = A ϖcos (ϖ t ) x = -A ϖ2 sin (ϖ t ) If a vibration has an acceleration of 0.1 g peak at 10 Hz, find the corresponding corresponding peak values of velocity and displacement. (Answer: a. 15.6 mm/sec, b. 0.24 mm)
7. Two vibrating systems systems are shown in the sketches. transmissibility for both systems:
100 mm peak
Determine
3.2 N peak 320 N peak
1mm peak
(no friction)
(Answer: a. 0.01, b. 0.01)
TAFE Mechanical Engineering
80
B. McLauchlan TAFE SI 2006
8.
What frequency ratio ( ie f/fn) is needed to provide: a. T = 0.4 b. T = 0.06 T is transmissibility c. T = 0.03 with damping ratio = 0 (Answer: a. 1.95, b. 4.1, c. 5.7)
9. Repeat question 8 for damping ratio = 0.1. effect of the increased increased damping on isolation.
What
is
the
(Answer: a. 2.2, b. 6, c. 8)
10. A vibrating vibrating machine machine is to be isolated from its base base with with T = 0.2. The machine has a mass of 295 kg and a forcing forcing frequency of 200 Hz. Find: a. natural frequency b. k to provide the required isolation. (Answer: a. 83.3 Hz, b. 80 MN/m) 11. A large turbine vibrates when operating at normal speed of 48 000 rpm. If the machine mass is 621 kg find: a. natural frequency b. system spring constant c. spring constant for each spring if a total of four equally loaded springs support the machine. The machine is to be provided with 90 % isolation. (Answer: a. 250 Hz, b. 1.5 GN/m, c. 383 MN/m)
TAFE Mechanical Engineering
81
B. McLauchlan TAFE SI 2006
12.SELECTION OF TRANSDUCERS TRANSDUCERS We are told that a peizo - electric accelerometer has a "mounted resonance frequency" of 18 kHz. Is this accelerometer suitable for measurement of vibration of a machine that is known to have significant vibration at 3kHz?
13.ERROR DETERMINATION DETERMINATION When measuring measuring vibration vibration on a machine,instruments machine,instruments were used with the following errors: transducer +/- 1% amplifier +/- 1.2% tape recorder +/- 3.5% FFT analyser +/- 0.5% The recorded data was analysed with the FFT analyser set on 100 Hz full scale. A recording recording of 5 minutes minutes duration duration is available for analysis. What is the expected expected amplitude amplitude error? error? 14.DIGITAL SAMPLING Data analysis of our vibration measurements will be made with a computer fitted with an analog to digital converter. The intended analysis is of amplitude distribution and frequency.The frequency analysis will be carried out by a FFT program available for the computer. The data is recorded on an FM tape recorder at a tape speed of 38.1 mm/sec. This speed has a linear frequency response to 1kHz. We are only concerned with data up to 500 Hz so the tape recorder is adequate for the purpose. Can we digitise this data? What precautions should we take to ensure correct analysis? What sample frequency should be chosen for digitising ?
15. CALIBRATION A servo accelerometer accelerometer is to be calibrated calibrated by the the static method. method. (ie using the earths' gravitational gravitational field field for a reference reference value) value) If the accelerometer can measure a maximum of 0.5g,it cannot be calibrated by by tilting through through 90 degrees. degrees. Find the angle,measured from the horizontal,that provides a 0.5 g calibration for this accelerometer. 16. A spring/mass spring/mass system has a mass mass m = 10 kg and a spring constant k = 500 N/m. Determine the natural natural frequency frequency of this system.
TAFE Mechanical Engineering
82
B. McLauchlan TAFE SI 2006
17. A spring has a 30 kg mass suspended on it. An additional 5kg mass is added and the spring deflects deflects a further 5mm from its previous position. Find the natural frequency of the system: a. with the 30 kg only only b. with the 5 kg added 18. The system in the first exercise exercise has a vibration of +/- 50mm at 2 Hz applied to the spring. spring. Find the magnitude of vibration of the mass. Assume zero damping. 19. Explain the term RESONANCE. If a spring/mass system has a natural frequency of 10 Hz,what conditions will cause resonance ? 20. For the system system in question question 19, a vibrating force force is applied applied to the mass. mass. The spring spring mass system is to be isolated isolated from the the base base that it is mounted mounted on. Rubber springs are are used with a damping ratio of 0. 2. If the force on the base is to be kept to a maximum maximum of +/- 200 Newtons,what is the maximum force that can be applied to the mass at a frequency of 35 Hz ? 21. On a tractor,whole body vibration measured an RMS magnitude of 0. 4 m/sec at 2.5 Hz. Determine the fatigue limit for this vibration if it is applied in the Az direction.
22. What would be the level of vibration for for the same exposure exposure time and frequency as question 21, but considering instead the comfort limit. 23. For vibration at 5 Hz, what what level of vibration is at the exposure exposure limit for 1 minute. Consider the Az direction only.
24. A vibration has a level of 0.4 g at 10Hz. fatigue limit in the Az direction?
What is the
25. What is the combined effect effect of the following vibrations vibrations in the Ax directions. Consider fatigue limits only and calculate the allowable time of exposure. Hz m/sec 1.0 0.5 2.0 0.4 10.0 0.8
TAFE Mechanical Engineering
83
B. McLauchlan TAFE SI 2006
Glossary Of Vibration Terms Terms CALIBRATION The process of comparing the measuring system with a known standard value to check accuracy DAMPING Loss of energy in a system that prevents continuous motion DAMPING RATIO Ratio of the actual amount of damping to a standard value Fast Fourier Transform This is a mathematical method for reducing time varying data to a frequency spectrum FFT Abbreviation for Fast Fourier Transform FILTER An electronic device that allows some frequencies to pass through while restricting or eliminating others. Types of filter are :band pass,high pass and low pass FREQUENCY The rate at which a periodic wave repeats itself. Measured in Hertz (Hz) g A common way of measuring acceleration for human effects evaluations. "g" = 9.8 m/s2 (acceleration (acceleration due to gravity) REYNAUDS' DISEASE Damage to human tissues and circulatory system resulting in VWF and sometimes amputation SEGMENTAL Refers to vibration that is applied to the bone structure of the hand and arm
TAFE Mechanical Engineering
84
B. McLauchlan TAFE SI 2006
SIGNAL A signal is an information information carrying wave. This term may describe describe the actual acoustic wave or its electrical analog as measured by a transducer SPECTRUM The frequency content of vibration can be expressed graphically as a spectrum TRANSDUCER A device for for converting energy energy from the parameter being measured measured into convenient form for measurement. Often the energy measured is converted to electricity TRANSMISSIBILITY A ratio that expresses the amount of force or displacement transmitted in a spring mass system VWF Vibration White Finger or Reynauds disease (see above) WAVELENGTH The length between successive similar features of a wave, such as from a peak to peak. Measured in meters. WEIGHTING A band pass filter that reduces the level of signal at some frequencies while maintaining or increasing others. Used to measure with a single value, the effect of the signal on humans or machines. WHOLE BODY Vibration that is applied to the whole human body rather than just a portion is called called Whole Whole Body Body vibration. vibration. Typically it is found in transportation vehicles.
TAFE Mechanical Engineering
85