Designation: D 1587 – 00
Standard Practice for
Thin-Walled Tube Sampling of Soils for Geotechnical Purposes1 This standard is issued under the fixed designation D 1587; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscript superscript epsilon (e) indicates an editorial change since the last revision or reapproval. This standard has been approved for use by agencies of the Department of Defense.
1. Scope Scope *
responsibility of the user of this standard to establish appro priate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.6 This practice practice offers offers a set of instruct instructions ions for performi performing ng one or more specific operations. This document cannot replace education or experience and should be used in conjunction with professional judgment. Not all aspects of this practice may be applicable in all circumstances. This ASTM standard is not intended to represent or replace the standard of care by which the adequacy of a given professional service must be judged, nor should this document be applied without consideration of a project’s many unique aspects. The word “Standard” in the title of this document means only that the document has been approved through the ASTM consensus process.
1.1 This practice covers a procedure for using using a thin-walled metal metal tube tube to recove recoverr relati relativel vely y undist undisturb urbed ed soil soil sample sampless suitable for laboratory tests of engineering properties, such as strength, strength, compressib compressibilit ility y, permeabili permeability ty,, and density density.. Thinwalled walled tubes tubes used used in piston piston,, plug, plug, or rotary rotary-ty -type pe sample samplers rs should should comply comply with with Sectio Section n 6.3 of this this practi practice ce which which describes the thin-walled tubes. NOTE 1—T 1—This his prac practic ticee does does not apply apply to liner linerss used used withi within n the the samplers.
1.2 This Practice is limited limited to soils that can be penetrated penetrated by the thin-w thin-wall alled ed tube. tube. This This sampli sampling ng method method is not recomrecommended for sampling soils containing gravel or larger size soil particles cemented or very hard soils. Other soil samplers may be used for sampling these soil types. Such samplers include driven split barrel samplers and soil coring devices (D 1586, D 3550, and D 6151). For information on appropriate use of other soil samplers refer to D 6169. 1.3 This This practi practice ce is often often used used in conjun conjuncti ction on with with fluid fluid rotary rotary drilli drilling ng (D 1452D 1452D 5783) 5783) or hollow hollow-st -stem em augers augers (D 6151). 6151). Subsur Subsurfac facee geotec geotechni hnical cal explor explorati ations ons should should be reported in accordance with practice (D 5434). This practice discusses some aspects of sample preservation after the sampling event. For information on preservation and transportation process of soil samples, consult Practice D 4220. This practice does not address environmental sampling; consult D 6169 and D 6232for information on sampling for environmental investigations. 1.4 The values stated in inch-pound inch-pound units are to to be regarded as the the stan standa dard rd.. The The SI valu values es give given n in pare parent nthe hese sess are are provided for information purposes only. The tubing tolerances presen presented ted in Table able 2 are from from source sourcess avail availabl ablee in North North America. America. Use of metric metric equivalen equivalentt is acceptabl acceptablee as long as thickness and proportions are similar to those required in this standard. standard rd does not purport purport to addre address ss all of the 1.5 This standa safe safety ty conc concer erns ns,, if any any, asso associ ciat ated ed with with its its use. use. It is the the
2. Referenced Documents 2.1 ASTM Standards: D 653 Standard Standard Terminol Terminology ogy Relating Relating to Soil, Rock, and 2 Contained Fluids D 1452 1452 Practi Practice ce for Soil Soil Invest Investiga igati tion on and Sampli Sampling ng by 2 Auger Borings D 1586 Penetration Resistance Resistance and Split Barrel Barrel Sampling of 2 Soils D 2488 Practice Practice for Descripti Description on and Identification Identification of Soils 2 (Visual-Manual (Visual-Manual Procedure) D 3550 Practice Practice for Ring-Lined Ring-Lined Barrel Barrel Sampling Sampling of Soils2 D 3740 3740 Minimum Minimum Requireme Requirements nts for Agencies Agencies Engaged Engaged in the Testing and/or Inspection of Soil and Rock as Used in Engineering Design and Construction 2 D 4220 4220 Practi Practices ces for Preser Preservin ving g and Trans Transpor portin ting g Soil Soil Samples2 D 5434 5434 Guide Guide for Field Field Loggin Logging g of Subsur Subsurfac facee Explor Exploraations of Soil and Rock 3 D 5783 Guide for Use of Rotary Drilling with Water-Based Water-Based Drilling Fluid for Geoenvironmental Exploration and the Installation of Subsurface Water-Quality Monitoring Devices3 D 6151 6151 Practice Practice for Using Using Hollow-St Hollow-Stem em Augers for Geotechnical Exploration and Soil Sampling 3 D 6169 6169 Guide Guide for Select Selection ion of Soil Soil and Rock Rock Sampli Sampling ng
1
This practice is under the jurisdiction of ASTM Committee D18 on Soil and Rock and is the direct responsibility of Subcommittee D18.02 on Sampling and Related Field Testing for Soil Investigations. Investigations. Current edition approved August 10, 2000. Published Published December 2000. Originally published as D 1587–58T. Last previous edition D 1587–83.
2 3
Vol 04.08. Annual Book of ASTM Standards, Standards, Vol Vol 04.09. Annual Book of ASTM Standards, Standards, Vol
*A Summary of Changes section appears at the end of this standard. Copyright © ASTM, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959, United States.
1
D 1587 TABLE 1 Suitable Thin-Walled Steel Sample TubesA Outside diameter (Do): in. mm Wall thickness: Bwg in. mm Tube length: in. m Inside clearance ratio, %
2 50.8
3 76.2
5 127
18 0.049 1.24
16 0.065 1.65
11 0.120 3.05
36 0.91 <1
36 0.91 <1
54 1.45 <1
specimen suitable for laboratory tests of engineering properties or other tests that might be influenced by soil disturbance. NOTE 2—The quality of the result produced by this standard is dependent on the competence of the personnel performing it, and the suitability of the equipment and facilities used. Agencies that meet the criteria of Practice D 3740 are generally considered capable of competent and objective sampling. Users of this practice. are cautioned that compliance with Practice D 3740 does not in itself assure reliable results. Reliable results depend on many factors; Practice D 5740 provides a means of evaluating some of those factors.
A The three diameters recommended in Table 1 are indicated for purposes of standardization, and are not intended to indicate that sampling tubes of intermediate or larger diameters are not acceptable. Lengths of tubes shown are illustrative. Proper lengths to be determined as suited to field conditions.
6. Apparatus 6.1 Drilling Equipment —When sampling in a boring, any drilling equipment may be used that provides a reasonably clean hole; that minimizes disturbance of the soil to be sampled; and that does not hinder the penetration of the thin-walled sampler. Open borehole diameter and the inside diameter of driven casing or hollow stem auger shall not exceed 3.5 times the outside diameter of the thin-walled tube. 6.2 Sampler Insertion Equipment , shall be adequate to provide a relatively rapid continuous penetration force. For hard formations it may be necessary, although not recommended, to drive the thin-walled tube sampler. 6.3 Thin-Walled Tubes, should be manufactured to the dimensions as shown in Fig. 1. They should have an outside diameter of 2 to 5 in. (50 to 130 mm) and be made of metal having adequate strength for the type of soil to be sampled. Tubes shall be clean and free of all surface irregularities including projecting weld seams. Other diameters may be used but the tube dimensions should be proportional to the tube designs presented here. 6.3.1 Length of Tubes—See Table 1 and 7.4.1. 6.3.2 Tolerances, shall be within the limits shown in Table 2. 6.3.3 Inside Clearance Ratio, should be not greater than 1 % unless specified otherwise for the type of soil to be sampled. Generally, the inside clearance ratio used should increase with the increase in plasticity of the soil being sampled, except for sensitive soils or where local experience indicates otherwise. See 3.2.1 and Fig. 1 for definition of inside clearance ratio. 6.3.4 Corrosion Protection —Corrosion, whether from galvanic or chemical reaction, can damage or destroy both the thin-walled tube and the sample. Severity of damage is a function of time as well as interaction between the sample and the tube. Thin-walled tubes should have some form of protective coating, unless the soil is to be extruded less than 3 days. The type of coating to be used may vary depending upon the material to be sampled. Plating of the tubes or alternate base metals may be specified. Galvanized tubes are often used when long term storage is required. Coatings may include a light coat of lubricating oil, lacquer, epoxy, Teflon, zinc oxide, and others.
TABLE 2 Dimensional Tolerances for Thin-Walled Tubes Nominal Tube Diameters from Table 1 A Tolerances Size Outside Diameter
2 in.
Outside diameter, Do +0.007 -0.000 Inside diameter, Di +0.000 -0.007 Wall thickness 60.007 Ovality 0.015 Straightness 0.030/ft
50.8 mm
3 in.
76.2 mm
5 in.
127 mm
+0.179 -0.000 +0.000 -0.179 60.179 0.381 2.50/m
+0.010 -0.000 +0.000 -0.010 60.010 0.020 0.030/ft
+0.254 -0.000 +0.000 -0.254 60.254 0.508 2.50/m
+0.015 -0.000 +0.000 -0.015 60.015 0.030 0.030/ft
0.381 -0.000 +0.000 -0.381 60.381 0.762 2.50/m
A Intermediate or larger diameters should be proportional. Specify only two of thefirst three tolerances; that is,D o and Di, o r Do andWallthickness, or Di and Wall thickness.
Devices Used With Drill Rigs for Environmental Investigations3 D 6232 Guide for Selection of Sampling Equipment for Waste and Contaminated Media Data Collection Activities4 3. Terminology 3.1 Definitions: 3.1.1 For common definitions of terms in this standard, refer to Terminology D 653. 3.2 Definitions of Terms Specific to This Standard: 3.2.1 inside clearance ratio, % —the ratio of the difference in the inside diameter of the tube, D i, minus the inside diameter of the cutting edge, D e, to the inside diameter of the tube, D i expressed as a percentage (see Fig. 1). 3.2.2 ovality—the cross section of the tube that deviates from a perfect circle. 4. Summary of Practice 4.1 A relatively undisturbed sample is obtained by pressing a thin-walled metal tube into the in-situ soil at the bottom of a boring, removing the soil-filled tube, and applying seals to the soil surfaces to prevent soil movement and moisture gain or loss. 5. Significance and Use
NOTE 3—Most coating materials are not resistant to scratching by soils that contain sands. Consideration should be given for prompt testing of the sample because chemical reactions between the metal and the soil sample con occur with time.
5.1 This practice, or Practice D 3550 with thin wall shoe, is used when it is necessary to obtain a relatively undisturbed
4
6.4 Sampler Head , serves to couple the thin-walled tube to the insertion equipment and, together with the thin-walled tube,
Annual Book of ASTM Standards, Vol 11.04.
2
D 1587
NOTE 1—Minimum of two mounting holes on opposite sides for Do smaller than 4 in. (101.6 mm). NOTE 2—Minimum of four mounting holes equally spaced for Do 4 in. (101.6 mm) and larger. NOTE 3—Tube held with hardened screws or other suitable means. NOTE 4—2-in (50.8 mm) outside-diameter tubes are specified with an 18-gage wall thickness to comply with area ratio criteria accepted for “undisturbed samples.” Users are advised that such tubing is difficult to locate and can be extremely expensive in small quantities. Sixteen-gage tubes are generally readily available. Metric Equivalent Conversions in. ⁄ 8 ⁄ 2 1 2 3 4 5
mm
3 1
9.53 12.7 25.4 50.8 76.2 101.6 127
FIG. 1 Thin-Walled Tube for Sampling
comprises the thin-walled tube sampler. The sampler head shall contain a venting area and suitable check valve with the venting area to the outside equal to or greater than the area through the check valve. In some special cases, a check valve may not be required but venting is required to avoid sample compression. Attachment of the head to the tube shall be concentric and coaxial to assure uniform application of force to the tube by the sampler insertion equipment.
exceed 5 to 10 diameters of the tube in sands and 10 to 15 diameters of the tube in clays. In no case shall a length of advance be greater than the sample-tube length minus an allowance for the sampler head and a minimum of 3-in. (75 mm) for sludge and end cuttings.
7. Procedure
7.5 When the soil formation is too hard for push-type insertion, the tube may be driven or Practice D 3550 may be used. If driving methods are used, the data regarding weight and fall of the hammer and penetration achieved must be shown in the report. Additionally, that tube must be prominently labeled a “driven sample.” 7.6 Withdraw the sampler from the soil formation as carefully as possible in order to minimize disturbance of the sample. The tube can be slowly rotated to shear the material at the end of the tube, and to relieve water and/or suction pressures and improve recovery. Where the soil formation is soft, a delay before withdraw of the sampler (typically 5 to 30 minutes) may improve sample recovery.
NOTE 5—The mass of sample, laboratory handling capabilities, transportation problems, and commercial availability of tubes will generally limit maximum practical lengths to those shown in Table 1.
7.1 Remove loose material from the center of a casing or hollow stem auger as carefully as possible to avoid disturbance of the material to be sampled. If groundwater is encountered, maintain the liquid level in the borehole at or above ground water level during the drilling and sampling operation. 7.2 Bottom discharge bits are not permitted. Side discharge bits may be used, with caution. Jetting through an open-tube sampler to clean out the borehole to sampling elevation is not permitted. NOTE 4—Roller bits are available in downward-jetting and diffused-jet configurations. Downward-jetting configuration rock bits are not acceptable. Diffuse-jet configurations are generally acceptable.
8. Sample Measurement, Sealing and Labeling
7.3 Lower the sampling apparatus so that the sample tube’s bottom rests on the bottom of the hole and record depth to the bottom of the sample tube to the nearest 0.1-ft (.03 m) 7.3.1 Keep the sampling apparatus plumb during lowering, thereby preventing the cutting edge of the tube from scraping the wall of the borehole. 7.4 Advance the sampler without rotation by a continuous relatively rapid downward motion and record length of advancement to the nearest 1 in. (25 mm). 7.4.1 Determine the length of advance by the resistance and condition of the soil formation, but the length shall never
8.1 Upon removal of the tube, remove the drill cuttings in the upper end of the tube and measure the length of the soil sample recovered to the nearest 0.25 in. (5 mm) in the tube. Seal the upper end of the tube. Remove at least 1 in. (25 mm) of material from the lower end of the tube. Use this material for soil description in accordance with Practice D 2488. Measure the overall sample length. Seal the lower end of the tube. Alternatively, after measurement, the tube may be sealed without removal of soil from the ends of the tube. 8.1.1 Tubes sealed over the ends, as opposed to those sealed 3
D 1587 with expanding packers, should be provided with spacers or appropriate packing materials, or both prior to sealing the tube ends to provide proper confinement. Packing materials must be nonabsorbent and must maintain their properties to provide the same degree of sample support with time. 8.1.2 Depending on the requirements of the investigation, field extrusion and packaging of extruded soil samples can be performed. This allows for physical examination and classification of the sample. Samples are extruded in special hydraulic jacks equipped with properly sized platens to extrude the core in a continuous smooth speed. In some cases, further extrusion may cause sample disturbance reducing suitability for testing of engineering properties. In other cases, if damage is not significant, cores can be extruded and preserved for testing (D 4220). Bent or damaged tubes should be cut off before extruding. 8.2 Prepare and immediately affix labels or apply markings as necessary to identify the sample (see Section 9). Assure that the markings or labels are adequate to survive transportation and storage.
9.1.1 Name and location of the project, 9.1.2 Boring number, 9.1.3 Log of the soil conditions, 9.1.4 Surface elevation or reference to a datum to the nearest foot (0.5 m) or better, 9.1.5 Location of the boring, 9.1.6 Method of making the borehole, 9.1.7 Name of the drilling foreman and company, and 9.1.8 Name of the drilling inspector(s). 9.1.9 Date and time of boring-start and finish, 9.1.10 Depth to groundwater level: date and time measured, 9.2 Recording the appropriate sampling information is required as follows: 9.2.1 Depth to top of sample to the nearest 0.1 ft. (.03 m) and number of sample, 9.2.2 Description of thin-walled tube sampler: size, type of metal, type of coating, 9.2.3 Method of sampler insertion: push or drive, 9.2.4 Method of drilling, size of hole, casing, and drilling fluid used, 9.2.5 Soil description in accordance with Practice D 2488, 9.2.6 Length of sampler advance (push), and 9.2.7 Recovery: length of sample obtained.
NOTE 6—Top end of the tube should be labeled “top”.
9. Field Log 9.1 Record the information that may be required for preparing field logs in general accordance to ASTM D 5434 “Guide for Field Logging of Subsurface Explorations of Soil and Rock”. This guide is used for logging explorations by drilling and sampling. Some examples of the information required include;
10. Keywords 10.1 geologic investigations; sampling; soil exploration; soil investigations; subsurface investigations; undisturbed
SUMMARY OF CHANGES In accordance with committee D18 policy, this section identifies the location of changes to this standard since the last edition, 1994, which may impact the use of this standard. (1) Editorial corrections to various sections based on comments received from Committee Balloting
(2) Added D 6232 to Section 2. (3) Changed Note 7 to Section 8.1.2. (4) Renumbered Note 8.
The American Society for Testing and Materials takes no position respecting the validity of any patent rights asserted in connection with any item mentioned in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, are entirely their own responsibility. This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards and should be addressed to ASTM Headquarters. Your comments will receive careful consideration at a meeting of the responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should make your views known to the ASTM Committee on Standards, at the address shown below. This standard is copyrighted by ASTM, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above address or at 610-832-9585 (phone), 610-832-9555 (fax), or
[email protected] (e-mail); or through the ASTM website (www.astm.org).
4