This is the Latest Mechanical Engineering Board Exam ReviewerFull description
Air Conditioning b767-300
Air Conditioning b767-300
A350
We know that the present air conditioning system produces cooling effect by refrigerants like Freon, Ammonia. Using this refrigerants can get maximum output but one of the major disadvantages is harmful gas emission and global warming. This problem c
Modeling a HVAC system using Simulink.Full description
BLEED CAUTION, do not use HP GND air with APU bleed AVIONICS VENTILATION CONFIGURATIONS: CLOSED, on GND (skin32°-35°C) then EXTRACT VLV partially opens OPEN, on GND (skin>9°-12°C) SMO…Full description
Refrigeration and Air conditioningFull description
Lab report Air-condFull description
BLEED CAUTION, do not use HP GND air with APU bleed AVIONICS VENTILATION CONFIGURATIONS: CLOSED, on GND (skin32°-35°C) then EXTRACT VLV partially opens OPEN, on GND (skin>9°-12°C) SMO…Full description
Design Guide - Air ConditioningFull description
Trane Air Conditioning ManualDescripción completa
Full description
Full description
report aircondFull description
This report contains vital information about the process of Air Conditioning and its principles.Architecture students may find it quite useful.Full description
Full description
Full description
boeing 737 systems Air conditioning
Smartcockpit.com
BOEING 767 SYSTEMS REVIEW
Page 1
AIR CONDITIONING
1. GENERAL ¡ Air conditioning is achieved by 2 identical PACKS, each of which controlled by a PACK CONTROL SELECTOR. ¡ Positioning the selector to AUTO or STBY sends an open signal to the PACK VALVE. ¡ Conditioned air from the packs flows into a common manifold where it mixes with air from 2 RECIRCULATION FANS. The mixed air is then ducted into the temperature controlled compartments of the airplane.
2. PACKS ¡ Pack switch on AUTO :
temperature control is automatic
¡ Pack switch on STBY : - N set pack for constant MODERATE temperature - C set pack for COLD operation* - W outlet temperature controlled by RAM AIR flowing across the heat exchangers* (* from 18°C to 30°C). ¡ HIGH FLOW when :
Ô ground operation when APU or GND air supplies the system Ô in flight when : - 1 PACK OFF or - 1 RECIRC. FAN U/S or OFF
¡ HIGH FLOW inhibited when
Ô using WING A/I and only 1 Bleed. Ô one engine INOP Ô FLAPS not in UP position Ô aft cargo compartment ARMED switch pushed
L/R PACK INOP
INOP : - Automatic control fault Ô Pack temperature valves freeze in the last controlled position. Pack cannot be reset and must be operated in STBY. INOP light + EICAS message go out when the Pack selector is rotated to PACK a STBY position. OFF - Overheat (internal or air leaving the pack) Ô Pack automatically set and locked to max cooling. After cooling, the Pack can be reset for automatic or standby operation by pushing the PACK RESET switch INOP light go out when the Pack selector and the Pack returns to the Selected control at reset. PACK OFF : - Pack valve closed due to : - pack shut down - selector OFF - loss of bleed air - overheat ¡ ONE reset, then set MANUAL (amber)
3. PACK VALVE ¡ The PACK VALVE is a flow control valve and requires air pressure to open. When open, the valve controls air flow to a scheduled rate based on airplane altitude.
Copyright Smartcockpit.com Ludovic ANDRE / version 00
Smartcockpit.com
BOEING 767 SYSTEMS REVIEW
Page 2
4. RECIRCULATION FAN ¡ Left & Right Recirculation Fans draw air which has been exhausted from the cockpit & passengers cabin through filters and returns the air to the mix manifold. There it mixes with conditioned air from the packs and is distributed again to the cabin. ¡ Purpose of recirculating cabin air is to maintain the desired level of passenger cabin ventilation while minimizing the use of bleed air. ¡ Recirculation Fans may be turned OFF several minutes to refresh the air in the cabin. ON
- ON : Recirculation fan signalled ON - INOP (amber) : Recirculation fan switch is OFF or the fan has failed + EICAS msg.
INOP
5. TEMPERATURE CONTROL ¡ The airplane is divided into 4 compartments for temperature control : - the flight deck - the FWD 1/3 cabin - mid-cabin - aft cabin ¡ Temperature controller signals the pack to produce air for the compartment requiring the coolest ¡ Trim air system then adjust the others (with air from downstream the pack valve) TRIM AIR ON
- ON : Trim air regulating valve signalled open - OFF (amber) : trim air switch is OFF + EICAS msg + 4 compartments INOP lights ON Packs then provide air for a 24°C cabin temperature
OFF INOP
(amber)
- Duct temperature overheat - Fault in the associated compartment temperature control system - Associated Passenger Compartment temperature Control OFF - Trim air OFF
¡ Setting the compartment selector to OFF, closes the respective Trim air & temperature is then controlled by the coolest compartment
6. CREW HEAT ¡ Additional electrical heater for each pilot usable IN FLIGHT only (side window & rudder pedal areas)
Copyright Smartcockpit.com Ludovic ANDRE / version 00
Smartcockpit.com
BOEING 767 SYSTEMS REVIEW
AIR CONDITIONING
Copyright Smartcockpit.com Ludovic ANDRE / version 00
Page 3
Smartcockpit.com
BOEING 767 SYSTEMS REVIEW
CABIN TEMPERATURE CONTROL
Copyright Smartcockpit.com Ludovic ANDRE / version 00
Page 4
Smartcockpit.com
BOEING 767 SYSTEMS REVIEW
LEFT PACK LOGIC
Copyright Smartcockpit.com Ludovic ANDRE / version 00