A valve used in a flush tank controllling controllling the flushing of fixture.
Flush valve
Mini Minimu mum m dist distan ance ce of a wat water er suppl supply y wel welll fro from m a disp dispos osal al fiel field. d.
30.5 30.5 m
Any liquid waste containing containing animal or or vegetable matter in Sewage 3 suspension or solution. Carbon dioxide 4 Component of fire extinguisher. An assembly consisting of a pulley wheel, side plates, plates, shaft, and Sheave 5 bearings over which a cable or roped is passed. A type of lighting that provides illumination to special special objects like Specific lighting 6 sculptures, flower arragements, etc. 1.50 m 7 Minimum length of a septic tank. Minimum distance of a water supply well from a seepage pit or 45.70 m 8 cesspool. A device that is basically a double throw switch of generally 3-pole 3-pole connection that will automatically automatically transfer the power from fr om the Automatic transfer standby generator to the building circuitry during electrical power switch 9 failure. Interrelationship between value of voltage and current with the Phase 10 same frequency. 11
Length along the centerline of the pipe and fitting.
Under NBC, the maximum rated speed of an escalator along the 12 angle of travel. inimum um dist istance ance of a water ater sup supply ply well well from from a sept septic ic tan tank. 13 Minim The typical angle of inclination of an escalator to the horizontal hor izontal 14 floor level? 15 Minimum trap diameter for bath tub. Flange used on a pipe to cover a hole or opening in a floor or wall 16 which the pipe pass. The minimum face to face distance between elevators in three thr ee and 17 four grouping. alternating current to direct current. 18 A device for converting alternating 19
Collec Collectio tion n line line of a plumbi plumbing ng system system is some sometim times es referre referred d to as: as:
Minimum elevator width of single slide door elevator for small 20 commercial or residential building. dimension of a manhole access to to a septic tank. 21 Minimum di Consists of a flyball or flyweight device designed to stop an 22 elevator. 23 Minimum trap diameter for a shower stall. 24 Another name for distribution panel. 25 Farad is the unit capacity of a ___. An instrument which responds responds to changes in temperature, temperature, and 26 directly or indirectly. gauge of ga galvanized sheet used for do downspouts. 27 Minimum ga
Development length 38 Meters/Min 15. 15.20 m 30 degrees 1 1/2" diameter Escutcheon 2.0 m Rectifier House House drain drain 0.60 m 508 mm mm Governor 2" Power panel Capacitor Thermostat 26
A
The transmission of heat energy from one place to another by 28 circulatory movement of a mass of fluid. A stop valve placed in the service pipe close to the connection at 29 the water main. A vent with a function to provide circulation if air between 30 drainage and vent system. 31
A unit of illuminatinon equivalent to 1 lumen per square meter.
Minimum length of the secondary compartment of a septic tank 32 with a capacity of more than 6 cubic meters. Minimum extension of the VSTR above an operable window, door 33 opening, air intake, or vent shaft. 34 Minimum extension of the VSTR above the roof. 35 Maximum height of a water seal for each fixture trap. 36
The other type of flame detector other than the ultraviolet type.
Another name for passenger elevator. The art and science of installing in buildings the pipes, fixtures, and other apparatus for bringing in water supply and removing 38 water and waterborne waste. Minimum capacity, in cubic meters, of the secondary 39 compartment of a septic tank. 37
B
Convection Corporation valve Relief vent Lux 1.50 m 0.90 m 15 cm 102 mm Infrared Lift Plumbing 1.00 cubic meter
A hoisting and lowering mechanism with a building equipped with Dumbwaiter relatively small car exclusively for carrying materials. 40
Minimum liquid depth of a septic tank. 42 Minimum height of a dumbwaiter. 43 Standard length of an electrical metal conduit. 44 Maximum liquid depth for septic tank. 45 A controller sensitive to the degree of moisture in the air. 46 Minimum width of a septic tank. 41
47
It characteries short circuit.
Standard size of wire for a circuit line. 49 Another name for a Rectifier. 50 Maximum length of the tailpiece from any fixture. 51 Condensing unit is a part of a ___. Minimum wire size in square millimeter for a branch circuit with a 30 ampere rating using Type THW stranded copper conductor 52 in a raceway. 48
53
Vertical flow of air used to separate different functions of spaces.
Heat rating for a fixed temperature heat detector. A device which extends across at least 1/2 the width of each door 55 leaf which will open if subjected to pressure. 54
60 cm 1.20 m 10' 1.80 cm Humidistat 90 cm Low resistance, high current No. 12 DC Generator 60 mm Refrigeration 5.5 sq.mm Air curtain 165-197 deg. F Panic bar
A
The installation of parts of the plumbing system which can be completed prior to installation of fixtures or finishing. This includes drainage, water supply and vent piping and necessary 56 fixture supports. Minimum head of water, in meters, required for each section of 57 plumbing for water test. The water supply pipe provided by the water utility company 58 where local individual connection is done. 59 Instrument used for measuring atmospheric pressure. A single vent that ventilates multiple traps in the case of a back to 60 back vent. 61 A vent pipe connected to a stack vent. Minimum sound pressure level that is capable of being detected 62 by the human ear.
B
Roughing-in
3 Water main Barometer Common vent Loop vent Threshold of audibility
A watertight receptacle which the discharge of sanitary plumbing system or part thereof, designed and constructed to retain solids, digest organic matter through a period of detention and to allow Septic tank the liquids to discharge into the soil outside of the tank through a system of open jointed subsurface piping or seepage pit. 63
64
Minimum height of a branch vent above the fixture it is venting.
6"
Minimum size of trap or branch for a bidet. 1 1/2" Sanitary sewage from buildings shall be discharged directly to the Main sanitary sewer 66 nearest ___. 1/8 bend 67 A type of pipe fitting for a Yoke Vent. Telecommunication The simplest type of building automation system. system 68 Unit of sound absorption equivalent to 1 square foot of perfectly Sabin 69 absorptive material. Term applied to the interconnection of the same fixture in one soil Battery of fixture 70 or waste branch with one branch vent. What is the rating index of an air-conditioning/refrigeration Energy Efficiency system which rates the unit for the number of BTUs of heat Rating 71 removed per watt of electrical input energy? (EER) 65
Minimum sie of a standpipe for a building in which the highest outlet is 23 meters or less from the fire service connection.
4"
72
A circuit type where components are electrically connected end to Parallel 73 end. It refers to an individual who worked in the sanitary field of Plumbarius 74 ancient Rome. A loosely lined excavation in the ground which receives the discharge of a septic tank and designed to permit the effluent from Cesspool the septic tank to seep through the bottom and sides of the pit. 75
A
Minimum distance of water pipings from any regulating equipment, water heater, conditioning tanks, and similar 76 equipment requiring union fittings. Standard frequency of power supplied by the local power utility 77 company like Meralco. During elevator emergency, to rescue passengers, this part of the 78 elevator is used to open the doors from the outside. The overhead service conductors from the last pole or other aerial support to and including splices, if any, connecting to the service 79 entrance conductors at the building. How many days, at least, shall be given before any plumbing work 80 inspection is done after written notice for inspection? Single lever valves used in kitchen sink and lavatory faucets or at 81 shower valves works by the principle of a ___. 82 Type of lighting dealing with relatively large area lighting. 83 The luminous intensity of light is expressed in ___. 84 Unit of loudness level. Minimum vertical distance from the bottom of water pipes to the top of sewer or drain pipe if laid in the same trench on top of the 85 other. 86 A vent pipe connected to a vent stack. A lamp designed to project and diffuse a uniform level of 87 illumination over a large area. Minimum lead content in percent for pipes and fittings safe for 88 humans. 89 Standard size of a wet standpipe outlet for each floor. Minimum size of a wet standpipe for a riser of more than 15 90 meters from the source. 91 Minimum size of trap and waste branch for a shower stall. A faucet fitted with a nozzle curving downward used as a draw-off 92 tap. Conveys storm water and terminates into a natural drainage such 93 as lakes or rivers. 94 Distance sound travels during each cycle of vibration. 95
The process of dissipating sound energy by converting it to heat.
B
300 mm 60 cycles Outside door latch Service drop 3 days Ball valve General lighting Candela Phon 300 mm Circuit vent Floodlight 0.08 1 1/2" 4" 2" Bibbcock Storm sewer Wavelength Sound absorption
A machine that converts mechanical energy into electrical energy, Alternator 96 a generator of alternating current. Freon in air-con must be compressed and liquefied in order to Heat 97 absorb ___. 98
Standard size of an outlet for a dry standpipe located at each floor. 2 1/2"
Minimum sie of trap and waste branch for a pedestal urinal. 3" What mechanical equipment, coupled with a central airconditioning system, is used to dehumidify and cool the air stream Fan coil unit 100 injected to a conditioned space? 99