Connection Diagrams 2017
Contents N.C. Remote Controlled (RC) Valve with Galit N.C. Electrically Controlled (EL) Valve with Aquative Solenoid N.C. Electrically Controlled (EL) Val Valve ve Pressure Reducing Valve (PR) using 29-100 Plastic Pilot (Black) Pressure Reducing Valve (PR) using 29-10R Plastic Mini Pilot (Black) N.C. Electrically Controlled Pressure Reducing Valve (PR/EL) using 29-100 Plastic Pilot (Black) and Aquative Solenoid Electrically Controlled Pressure Reducing Valve (PR/EL) using 29-10R Plastic Mini Pilot (Black) N.C. Electrically Controlled Pressure Reducing Valve (PR/EL) using 29-100 Plastic Pilot (Black) Electrically Controlled Pressure Reducing Valve (PR/EL) using 29-10R Plastic Mini Pilot (Black) N.C. Remotely Controlled Pressure Reducing Valve (PR/RC) using 29-100 Plastic Pilot (Black) Remotely Controlled Pressure Reducing Valve (PR/RC) using 29-10R Plastic Mini-Pilot (Black) Pressure Reducing Valve (PR) using 29-200 Plastic Pilot (Blue) N.C. Electrically Controlled Pressure Reducing Valve (PR/EL) using 29-200 Plastic Pilot (Blue) and Aquative Solenoid N.C. Electrically Controlled Pressure Reducing Valve (PR/EL) using 29-200 Plastic Pilot (Blue) Pressure Reducing Valve (PR) using 31-10R Metal Pilot N.C. Electrically Controlled Pressure Reducing Valve (PR/EL) using 31-10R Metal Pilot Remotely Controlled Pressure Reducing Valve (PR/RC) using 31-10R Metal Pilot
8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 2
Contents Pressure Reducing Valve (PR) using 31-310 Metal Pilot N.C. Electrically Controlled Pressure Reducing Valve (PR/EL) using 31-310 Metal Pilot N.C. Remotely Controlled Pressure Reducing Valve Valve (PR/RC) using 31-310 Metal Pilot Pressure Reducing Valve (PR) using 68-410 Metal Pilot N.C. Electrically Controlled Pressure Reducing Valve (PR/EL) using 68-410 Metal Pilot Non-Return, Pressure Reducing Valve (PR/CV) using 68-410 Metal Pilot Proportional Pressure Reducing Valve (PRD) Pressure Sustaining Valve (PS) using 29-200 Plastic Pilot (Blue) N.C. Electrically Controlled Pressure Sustaining Valve (PS/EL) using 29-200 Plastic Pilot (Blue) and Aquative Solenoid N.C. Electrically Controlled Pressure Sustaining Valve (PS/EL) using 29-200 Plastic Pilot (Blue) Pressure Sustaining Valve (PS) using 31-10S Metal Pilot N.C. Electrically Controlled Pressure Sustaining Valve (PS/EL) using 31-10S Metal Pilot Pressure Sustaining Valve (PS) using 31-310 Metal Pilot N.C. Electrically Controlled Pressure Sustaining Valve Valve (PS/EL) using 31-310 Metal Pilot Pressure Sustaining Valve (PS) using 68-510 Metal Pilot N.C. Electrically Controlled Pressure Sustaining Valve (PS/EL) using 68-51A Metal Pilot 3
25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
Contents Pressure Sustaining Valve (PS) using CXPS Metal Pilot N.C. Electrically Controlled Pressure Sustaining Valve (PS/EL) using CXSD Metal Pilot Flow Rate Control Valve (FR) using 29-310 Plastic Pilot Flow Rate Control Valve (FR) using 31-10F Metal Pilot (up to 6") Flow Rate Control Valve (FR) using 76-200 Metal Pilot (8" and larger) Excessive Flow Shut-off Valve (FE) using 31-10F Metal Pilot Differential Vertical Float Controlled Valve (FLDI1) using 70-550 Plastic Float Actuated Metal Pilot Differential Horizontal Float Controlled Valve (FLDI2) using 70-610 Plastic Float Actuated Metal Pilot Modulating Float Controlled Valve (FL) using 70-300 Plastic Float Actuated Plastic Pilot Modulating Float Controlled Valve (FL) using 70-400 Plastic Float Actuated Metal Pilot Altitude Control Valve (AL) using 70-110 Metal Pilot Pressure Reducing and Sustaining Valve (PRPS) using 29-100 (Black) and 29-200 (Blue) Plastic Pilots N.C. Electrically Controlled Pressure Reducing and Sustaining Valve (PRPS/EL) using 29-100 (Black) and 29-200 (Blue) Plastic Pilots N.C. Electrically Controlled Pressure Reducing and Sustaining Valve (PRPS/EL) using 29-100 (Black) and 29-200 (Blue) Plastic Pilots
41 42 43 44 45 46 47 48 49 50 51 52
53
54
4
Contents Electrically Controlled Pressure Reducing and Sustaining Valve (PRPS/EL) using 29-10R (Black) and 29-200 (Blue) Plastic Mini Pilots Pressure Reducing and Sustaining Valve (PRPS) using 31-10R and 31-10S Metal Pilots N.C. Electrically Controlled Pressure Reducing and Sustaining Valve (PRPS/EL) using 31-10R and 31-10S Metal Pilots Pressure Reducing and Sustaining Valve (PRPS) using 31-310 Metal Pilots N.C. Electrically Controlled Pressure Reducing and Sustaining Valve (PRPS/EL) using 31-310 Metal Pilots Quick Relief Valve (QR) using 68-510 Metal Pilot (up to 2") Quick Relief Valve (QR) using 68-510 Metal Pilot (3" and 6") Quick Relief Valve (QR) using 68-510 Metal Pilot (8" and larger) Quick Relief Valve (QR) using 68-215 Metal Pilot (1 1 /2" - 4") Pump Controlled Valve (BC) using 300 Series Surge Anticipating Valve (RE) using 68-510 and 31-10R Metal Pilots (up to 4") Control Accessories - General Solenoid Aquative 3-Way Solenoid Solenoid Gemsol 3-Way Solenoid
5
55 56
57 58
59 60 61 62 63 64 65 66 68 69
Contents 29-100 Pressure-Reducing, 3-Way Plastic Pilot-Valve 29-10R Pressure-Reducing, 3-Way Plastic Pilot-Valve 29-200 Multi-Purpose, 3-Way Plastic Pilot-Valve 29-310 Differential Pressure Reducing, 3-Way Plastic Pilot-Valve 68-215 Quick-Acting, 2-Way Pressure-Relief Metal Pilot-Valve 68-410 Pressure-Reducing, 2-Way Metal Pilot-Valve 68-510 Pressure-Sustaining/Relief, 2-Way Metal Pilot-Valve 31-10R Pressure-Reducing, 3-Way Metal Pilot-Valve 31-10S Pressure-Sustaining, 3-Way Metal Pilot-Valve 31-10F Rate of Flow, 3-Way Metal Pilot-Valve 31-310 Multi-Purpose, 3-Way Metal Pilot-Valve 66-310 Multi-Purpose 3-Way Metal Pilot And Relay-Valve CXPR Pressure-Reducing, 2-Way Metal Pilot-Valve CXPS Pressure-Sustaining/Relief, 2-Way Metal Pilot-Valve 76-200 Multi Purpose, 3-Way Metal Pilot-Valve 70-110 Altitude Control, 3-Way Metal Pilot-Valve
70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 6
Contents 70-300 Modulating, 2-Way Float Actuated Plastic Pilot-Valve 70-400 Modulating, 2-Way Float Actuated Metal Pilot-Valve 70-550 Differential, 3 Or 4-Way Vertical Float Actuated Metal Pilot-Valve 70-610 Differential, 3-Way Horizontal Float Actuated Metal Pilot-Valve 25-300 Hydraulic Accelerator Relay, 3-Way Plastic Pilot-Valve Galit Hydraulic Relay, 3-Way Plastic Pilot-Valve 28-200 Hydraulic Accelerator Relay, 2-Way Metal Pilot-Valve 28-300 Hydraulic Accelerator Relay, 3-Way Metal Pilot-Valve Hydraulic Equations Units Conversion
7
86 87 88 89 90 91 92 93 94 95
N.C. Remote Controlled (RC) Valve with Galit
Remote control connection
1 4 2 3
8
N.C. Electrically Controlled (EL) Valve with Aquative Solenoid
B C
V P
9
A
N.C. Electrically Controlled (EL) Valve
2
1
N.O. C
10
Pressure Reducing Valve (PR) using 29-100 Plastic Pilot (Black)
29-100
1
2
C
A
O
11
3 4
Pressure Reducing Valve (PR) using 29-10R Plastic Mini Pilot (Black)
29-10R
1
2
C
3 4
A
O
12
N.C. Electrically Controlled Pressure Reducing Valve (PR/EL) using 29-100 Plastic Pilot (Black) and Aquative Solenoid
29-100
1
B V
C P
13
A
2
3 4
Electrically Controlled Pressure Reducing Valve (PR/EL) using 29-10R Plastic Mini Pilot (Black)
29-10R
1
B V
C P
2 4
3
A
14
N.C. Electrically Controlled Pressure Reducing Valve (PR/EL) using 29-100 Plastic Pilot (Black)
29-100
1
2 2 N.O. C
A O
15
C
1
3 4
Electrically Controlled Pressure Reducing Valve (PR/EL) using 29-10R Plastic Mini Pilot (Black)
29-10R 1
2
3 4
2 N.O. C
A C
1
O
16
N.C. Remotely Controlled Pressure Reducing Valve (PR/RC) using 29-100 Plastic Pilot (Black)
Remote control connection
29-100
1
2
4 3
17
1 2 4
3
Remotely Controlled Pressure Reducing Valve (PR/RC) using 29-10R Plastic Mini-Pilot (Black)
Remote control connection
29-10R
1 1
2
4 3
2 4
3
18
Pressure Reducing Valve (PR) using 29-200 Plastic Pilot (Blue)
29-200
1 2 4 C
A
O
19
3
N.C. Electrically Controlled Pressure Reducing Valve (PR/EL) using 29-200 Plastic Pilot (Blue) and Aquative Solenoid
29-200
1
B V
C P
2 4
3
A
20
N.C. Electrically Controlled Pressure Reducing Valve (PR/EL) using 29-200 Plastic Pilot (Blue)
29-200
1 2 4 2 N.O. C
A 1 O
21
C
3
Pressure Reducing Valve (PR) using 31-10R Metal Pilot
31-10R
1 2 4
C
3
A
O
22
N.C. Electrically Controlled Pressure Reducing Valve (PR/EL) using 31-10R Metal Pilot
31-10R
1
2 4
3-way N.O 3 C
A
O
23
2 1
Remotely Controlled Pressure Reducing Valve (PR/RC) using 31-10R Metal Pilot
31-10R
1
2 4
Remote control connection 3 2
3
4
1
24
Pressure Reducing Valve (PR) using 31-310 Metal Pilot
31-310
2
1
4
3
C
A
O
25
N.C. Electrically Controlled Pressure Reducing Valve (PR/EL) using 31-310 Metal Pilot
31-310
1
3-way N.O 1 2
2
3 4
C
A O
26
N.C. Remotely Controlled Pressure Reducing Valve (PR/RC) using 31-310 Metal Pilot
31-310
Remote control connection 2
1
4
2
3
3
27
4
1
Pressure Reducing Valve (PR) using 68-410 Metal Pilot
68-410
Orifice
0 IN
OUT I
0
28
N.C. Electrically Controlled Pressure Reducing Valve (PR/EL) using 68-410 Metal Pilot
68-410
1 2
0
OUT
IN I
Orifice
29
IN 0
3-way N.O 1 2
28-200
Non-Return, Pressure Reducing Valve (PR/CV) using 68-410 Metal Pilot
68-410
Orifice
0 IN
OUT I
0
Check Valve
Check Valve
30
Proportional Pressure Reducing Valve (PRD)
31
Pressure Sustaining Valve (PS) using 29-200 Plastic Pilot (Blue)
29-200
1
2 4 C
3
A O
32
N.C. Electrically Controlled Pressure Sustaining Valve (PS/EL) using 29-200 Plastic Pilot (Blue) and Aquative Solenoid
29-200
1 C 2
C
A O
33
3 4
A
P
B V
N.C. Electrically Controlled Pressure Sustaining Valve (PS/EL) using 29-200 Plastic Pilot (Blue)
29-200 2 N.C. 1 2 4 C
C
1
3
A O
34
Pressure Sustaining Valve (PS) using 31-10S Metal Pilot
31-10S
1 2 4
C
3
A O
35
N.C. Electrically Controlled Pressure Sustaining Valve (PS/EL) using 31-10S Metal Pilot
3-way N.C
31-10S
1 2 1 2 4
C
3
A O
36
Pressure Sustaining Valve (PS) using 31-310 Metal Pilot
31-310
1
3 4 2
C
A O
37
N.C. Electrically Controlled Pressure Sustaining Valve (PS/EL) using 31-310 Metal Pilot
31-310
3-way N.C
1 2 1
3 4 2
C
A O
38
Pressure Sustaining Valve (PS) using 68-510 Metal Pilot
68-510
I I
0
39
N.C. Electrically Controlled Pressure Sustaining Valve (PS/EL) using 68-51A Metal Pilot
68-51A 3-way N.C I
2 1 Orifice
0 C
40
Pressure Sustaining Valve (PS) using CXPS Metal Pilot
CXPS
I
0
I
C
41
N.C. Electrically Controlled Cont rolled Pressure Sustaining Valve Valve (PS/EL) using CXSD Metal Pilot
3-way N.O CXSD
I
1 2 0
I
C
42
Flow Rate Control Con trol Valve (FR) using 29-310 Plastic Pilot
29-310 1 5
2 4 C
A O
Orifice Plate 43
3
Flow Rate Control Con trol Valve (FR) using 31-10F Metal Pilot (up to 6")
31-10F
5
1
2 4
3 C
A O
Orifice Plate 44
Flow Rate Control Valve (FR) using 76-200 Metal Pilot (8" and larger)
76-200
5
1 2
3 4
C
A O
Orifice Plate 45
Excessive Flow Shut-off Valve (FE) using 31-10F Metal Pilot
31-10F
5 2 3 1
4 C
A O
Orifice Plate 46
Differential Vertical Float Controlled Valve (FLDI1) using 70-550 Plastic Float Actuated Metal Pilot
70-550
B
T
P Va C
A O
47
Differential Horizontal Float Controlled Valve (FLDI2) using 70-610 Plastic Float Actuated Metal Pilot
2 3
70-610
4
C
A O
48
Modulating Float Controlled Valve (FL) using 70-300 Plastic Float Actuated Plastic Pilot
70-300
Orifice
49
Modulating Float Controlled Valve (FL) using 70-400 Plastic Float Actuated Metal Pilot
70-400
Orifice
50
Altitude Control Valve (AL) using 70-110 Metal Pilot
70-110 Connection to tank
1
3 4 2
C
A O
51
Pressure Reducing and Sustaining Valve (PRPS) using 29-100 (Black) and 29-200 (Blue) Plastic Pilots
29-200
29-100
1 2 4
3 1 2 4
C
3
A O
52
Pressure Reducing and Sustaining Valve (PRPS) using 29-10R (Black) and 29-200 (Blue) Plastic Mini Pilots
29-200
1
29-10R 2 4
3
1
2 4
C
A O
53
3
N.C. Electrically Controlled Pressure Reducing and Sustaining Valve (PRPS/EL) using 29-100 (Black) and 29-200 (Blue) Plastic Pilots 2
29-200
N.C.
1
29-100
C 2 4
1 3 1 2 4
C
3
A O
54
Electrically Controlled Pressure Reducing and Sustaining Valve (PRPS/EL) using 29-10R (Black) and 29-200 (Blue) Plastic Mini Pilots
2
29-200
N.O.
1 1
C
29-10R 2
3 4
1
2
C
A O
55
3 4
Pressure Reducing and Sustaining Valve (PRPS) using 31-10R and 31-10S Metal Pilots
1 3 2
2
4 3
4
1
C
A O
56
N.C. Electrically Controlled Pressure Reducing and Sustaining Valve (PRPS/EL) using 31-10R and 31-10S Metal Pilots
31-10R
1
31-10S
3-way N.C 3 2
2
4 3 1 1 2 C
A O
57
4
Pressure Reducing and Sustaining Valve (PRPS) using 31-310 Metal Pilots
31-310 (PR) 2
31-310 (PS)
1 1
3 4
3 4 2 C
A O
58
N.C. Electrically Controlled Pressure Reducing and Sustaining Valve (PRPS/EL) using 31-310 Metal Pilots
31-310 (PS) 31-310 3-way N.C (PR) 2 3 1
4
1 2
1
3 4 2 C
A O
59
Quick Relief Valve (QR) using 68-510 Metal Pilot (up to 2")
68-510
I I
0
C
60
Quick Relief Valve (QR) using 68-510 Metal Pilot (3" and 6")
68-510
I I
0 C 1 Needle Valve
28-200 2
61
Quick Relief Valve (QR) using 68-510 Metal Pilot (8" and larger)
68-510
I I
0 C
Needle Valve
62
Quick Relief Valve (QR) using 68-215 Metal Pilot (11/2" - 4")
I
63
0
Pump Controlled Valve (BC) using 300 Series
Needle Valve
3-way N.C
Needle Valve
1 2
Check Valve
Check Valve
64
Surge Anticipating Valve (RE) using 68-510 and 31-10R Metal Pilots (up to 4")
31-10R
68-510
3 0
4
28-200 1
Connected to pump main header
65
1
2
I
2
Control Accessories - General Pressure Reducing (PR): The valve will regulate to maintain a set downstream pressure, regardless of upstream pressure or flow variations. Should the downstream pressure fall below the requested value, the valve will open fully. Pressure Sustaining (PS): The valve will maintain a steady, predetermined pressure in the network, upstream of its location. If the pressure falls below the set-pressure, the valve closes drip tight. 3-way Pilot Valves: Ports Marking: S - Pressure sensing port P - Port for connection of upstream pressure. C - Command port, connected to the valve control chamber. V - Vent port. Through this port water are vented when the valve opens. Operating Principle: CLOSE - Connects ports P to C thus letting the upstream pressure into the valve bonnet. OPEN - Connects ports C to V thus venting the pressure in the valve bonnet. LOCK - Keep the valve in the present position by blocking all ports.
66
2-way Pilot Valves: Operating Principle: Increases or decreases a drainage passage from the valve control chamber to downstream. The inlet to the chamber is via a fixed orifice or a regulated needle valve. CLOSE - The drainage flow through the pilot is smaller than the inlet flow. OPEN - The drainage flow through the pilot is larger than the inlet flow. LOCK - The drainage flow through the pilot is equal to the inlet flow.
3-way Manual Selector Valve: A ball valve with one common (fixed) port and three functional ports: “CLOSE” - Connected to the upstream. “OPEN” - Vented to the atmosphere. “AUTO” - Connected to the command port of the control device (pilot, solenoid etc.).
Needle Valve / Orifice: For flow limitation in the control system and reduction of the response speed of the main valve.
Shuttle Valve: Tee shaped pressure selector selecting the higher pressure when the valve is controlled by two pressure sources. 67
Solenoid Aquative 3-Way Solenoid No De-energized
B (vent)
No Energized
B COM (vent) (command)
A (pressure)
COM (command) A (pressure)
NC De-energized
B (pressure)
COM (command)
NC Energized
B (pressure)
A (vent)
COM (command)
A (vent)
Note: NC/NO is refering to the Hydraulic valve
68
Solenoid Gemsol 3-Way Solenoid Converts electric pulses to an hydraulic command Ports Marking: P - Pressure port. Connected to the upstream pressure. C - Connected to the control chamber of the valve. V - Pressure venting port.
2
1 C P
P
Normally open (2)
C
V
(1)
(2)
V
C
De-Energised
(1)
Energised
V
V
Normally closed (2) C
P
De-Energised 69
(1)
(2)
P (1)
C
Energised
29-100 Pressure-Reducing, 3-Way Plastic Pilot-Valve
1
2
3 4
Low pressure
High pressure
Required pressure
Connections Port 1 2 3 4
Pressure Reducing Downstream Valve Control Chamber Vent Upstream 70
29-10R Pressure-Reducing, 3-Way Plastic Pilot-Valve
1
2
3
4
Low pressure
High pressure
Required pressure
Connections Port 1 2 3 4 71
Pressure Reducing Downstream Upstream Valve Control Chamber Vent
29-200 Multi-Purpose, 3-Way Plastic Pilot-Valve
1
2
3
4
Low pressure
High pressure
Required pressure
(Shown in Pressure Reducing mode)
Connections Port 1 2 3 4
Pressure Sustaining Upstream Upstream Valve Control Chamber Vent
Pressure Reducing Downstream Vent Valve Control Chamber Upstream 72
29-310 Differential Pressure Reducing, 3-Way Plastic Pilot-Valve
5
1
2
3 4
Low differential pressure
High differential pressure
Required differential pressure
Connections Port 1 2 3 4 5 73
Flow Rate Upstream orifice pressure Upstream Valve Control Chamber Vent Downstream orifice pressure
68-215 Quick-Acting, 2-Way Pressure-Relief Metal Pilot-Valve
I
O
C
Low pressure
High pressure
Connections Port I C 0
Shown in Quick Pressure Relief Upstream Valve Control Chamber Downstream 74
68-410 Pressure-Reducing, 2-Way Metal Pilot-Valve
I
Low pressure
O
High pressure
Required pressure
Connections Port I1 I2 01 02 75
Pressure Reducing Valve Control Chamber Upstream (Through Orifice) Downstream Pressure gauge (optional)
68-510 Pressure-Sustaining/Relief, 2-Way Metal Pilot-Valve
I
O
C
Low pressure
Hi h ressure
High pressure
Connections Port I C O
Pressure Sustaining / Relief Upstream Valve / Relay Control Chamber Downstream 76
31-10R Pressure-Reducing, 3-Way Metal Pilot-Valve
1
2
3 4
Low pressure
High pressure
Required pressure
Connections Port 1 2 3 4 5 77
Pressure Reducing Downstream Upstream Valve Control Chamber Vent -
Differential P. Reducing High Sensing Pressure Upstream Valve Control Chamber Vent Low Sensing Pressure
31-10S Pressure-Sustaining, 3-Way Metal Pilot-Valve
1
2
3 4
Low pressure
High pressure
Required pressure
Connections Port 1 2 3 4 5
Pressure Sustaining Upstream Pressure Vent Valve Control Chamber Upstream Pressure -
Differential P. Sustaining Upstream Pressure Vent Valve Control Chamber Upstream Pressure Downstream Pressure 78
31-10F Rate of Flow, 3-Way Metal Pilot-Valve
5
1
2
3 4
Low pressure
High pressure
Required pressure
Connections Port 1 2 3 4 5 79
Flow Rate Upstream Orifice Plate Upstream Orifice Plate Valve Control Chamber Vent Downstream Orifice Plate
31-310 Multi-Purpose, 3-Way Metal Pilot-Valve
z
1
2
3
4
z
z
z
Low pressure
High pressure
Required pressure
(Shown in Pressure Reducing mode)
Connections Port 1 2 3 4
Pressure Reducing Downstream Pressure Vent Valve Control Chamber Upstream Pressure
Pressure Sustaining Upstream Pressure Upstream Pressure Valve Control Chamber Vent 80
66-310 Multi-Purpose 3-Way Metal Pilot And Relay-Valve
1
2
3
4
Low pressure
High pressure
(Shown in Pressure Relief mode)
Connections Port 1 2 3 4 81
66-310 / 68-710 P. Relief Upstream Plugged Valve Chamber Vent
66-310: Relay Command N.O. Port Valve Chamber N.C. Port
CXPR Pressure-Reducing, 2-Way Metal Pilot-Valve
C
O
I
Low pressure
High pressure
Connections Port I C O
Pressure Reducing Upstream Valve Control Chamber Downstream 82
CXPS Pressure-Sustaining/Relief, 2-Way Metal Pilot-Valve
I
O
C
Low pressure
High pressure
Connections Port I C O 83
Pressure Sustaining Upstream Valve Control Chamber Downstream
76-200 Multi Purpose, 3-Way Metal Pilot-Valve
5
z
1 3
2
4 z
z
z
Low flow High flow Required flow (Shown in Flow-rate control mode)
Connections Port 1 2 3 4 5
Flow-rate control Upstream Orifice Vent Control Chamber Upstream Orifice Downstream Orifice
Excessive flow Shut-Off Upstream Orifice Plug Control chamber Upstream Orifice Downstream valve 84
70-110 Altitude Control, 3-Way Metal Pilot-Valve
1 3
2
4
Low pressure
High pressure
Required pressure
Connections Port 1 2 3 4 85
Altitude Sensing Upstream Valve Control Chamber Vent
70-300 Modulating, 2-Way Float Actuated Plastic Pilot-Valve
High level
Low level
86
70-400 Modulating, 2-Way Float Actuated Metal Pilot-Valve
Max. level
87
Low level
70-550 Differential, 3 Or 4-Way Vertical Float Actuated Metal Pilot-Valve
Max. level
Max. level
Max. level
Min. level
Min. level
Min. level
Connections Port P T V B
Level control Upstream Valve Control Chamber Vent Plug* 88
70-610 Differential, 3-Way Horizontal Float Actuated Metal Pilot-Valve 2 3 4
Max. level
Max. level
Max. level
Min. level
Min. level
Min. level
Connections Port 2 3 4 89
Upstream Valve Control Chamber Vent
25-300 Hydraulic Accelerator Relay, 3-Way Plastic Pilot-Valve 1
2 3 4
De-pressurized command
Pressurized command
Connections Port 1 2 3 4
Relay N.C. Pressure Command Vent Valve Control Chamber Upstream 90
Galit Hydraulic Relay, 3-Way Plastic Pilot-Valve
1
2
4
3
De-pressurized command
Pressurized command
(Shown in N.C. Main Valve mode)
Connections Port 1 2 3 4 91
N.C. Main Valve Pressure Command Upstream Pressure Vent Valve Control Chamber
N.O. Main Valve Pressure Command Vent Upstream Pressure Valve Control Chamber
28-200 Hydraulic Accelerator Relay, 2-Way Metal Pilot-Valve 1
2
3
De-pressurized command
Pressurized command
Connections Port 1 2
Command Inlet 92
28-300 Hydraulic Accelerator Relay, 3-Way Metal Pilot-Valve 1
2
3
4
N.O.
De-pressurized command
Pressurized command
N.C.
De-pressurized command
Pressurized command
Connections Port 1 2 3 4 93
Relay N.C Command Vent Valve Control Chamber Upstream
Relay N.O. Command Upstream Valve Control Chamber Vent
Hydraulic Equations Headloss Calculation
Q=gpm Cv - taken from the technical publications Result given in PSI
Q=m3 /h Kv - taken from the technical publications Result given in Bar
Headloss Calculation Using K (Dimensionless)
v=f/s g=32.17f/s2 Result given in PSI
v=m/s g=9.8m/s2 Result given in mwc
Relief Valve Sizing
Q=gpm - Relief flow (designed flow at set relief pressure) P=psi - Required set pressure Result given in inches
Q=m3 /h - Relief flow (designed flow at set relief pressure) P=mwc - Required set pressure Result given in mm
Cavitation Calculation
P=psi For Dorot 300 Series σc ≥1.45 is safe For Dorot 100 & 500 Series σc ≥ 1.55 is safe
P=mwc For Dorot 300 Series σc ≥ 1.45 is safe For Dorot 100 & 500 Series σc ≥ 1.55 is safe
94
Units Conversion Port
Pressure
Length
Volume
Weight
Flow Rate
Velocity
95
Unit
Conversion Unit
Factor
1 psi
bar
0.06895
1 bar
psi
14.5035
1 Kg / cm2
psi
14.22
1 psi
Kg / cm2
0.07
1 kPa
bar
0.01
1 bar
kPa
100
1 metre
bar
0.1
1 bar
metre
10
1 inch
mm
25.4
1 mm
1 inch
0.03934
1 ft
metre
0.3048
1 metre
ft
3.28064
m3
gal
264.2
gal
m3
0.00378
m3
ft3
35.315
ft3
m3
0.0283
1 gal
litre
3.78533
1 litre
gal
0.264177
1 lb
kg
0.453592
1 kg
lb
2.204622
1 m3 / h
gpm
4.405
1 gpm
m3 / h
0.227
1 gal / min (US)
l / min
3.78533
1 l / min
1 gal / min (US)
0.264178
1l/s
gpm
15.873
1 gpm
l/s
0.063
1 ft / s
m/s
0.3048
1m/s
ft/s
3.28084