Corus Bausysteme
Construction details Kalzip® roof systems
Preface
Planning Guidance
Kalzip® aluminium roofing systems are suitable for a wide variety of applications and not only offer a lengthy service life but also excellent economic efficiency. Their compliance with the current requirements of construction physics relating to fire/acoustic protection and the EnEV energy-saving directives is exemplary. These construction recommendations are based on state-of-the-art technology. They are provided to the best of our knowledge and based on our experience and studies. They do not refer to any specific application and cannot give rise to any claims for compensation. We reserve the right to make any changes to the construction or product range which seem technically sensible in view of our high demands for quality and progress. The vendor accepts no liability for the advice rendered to the purchaser within the framework of the technical service which he provides. All drawings, sales documents or other suggested structures, procedures and ideas are presented without obligation to the purchaser for checking. It is the duty of the purchaser to ensure that there is no infringement of the trade mark rights (protection rights/industrial property rights?) of a third party. The constructional details represent suggestions for roof structures designs which have two shells and must be adapted to suit the actual constructional facts and conditions. The design of these types of structures requires careful planning, calculation, skilled preparation and installation. For this reason, all conditions and facts relating to use, in particular those relating to construction physics, must be taken into consideration. Standard constructions, which fulfil all requirements, are not possible.
Kalzip® plastic compound clip Kalzip® compound clips are not available in all sizes. All details are also applicable to the use of aluminium clips. Standards/instructions The current applicable standards and manufacturer’s instructions should be observed. Air tightness All room sealing connections should be made air-tight in accordance with the EnEV energy-saving directives. Fixed points/ fasteners Fixed points and featured fasteners should be used in accordance with the static calculations.
May 2004 This construction guide replaces all previous construction details.
Contents
Construction details truss roof/purlin roof Construction 101 102
Kalzip® deck roof system - rafter roof Kalzip® deck roof system - purlin roof
Ridge
121 122 123 124 125 126
Duo-pitch ridge Duo-pitch ridge Mono-pitch ridge Abutment ridge to parapet Mono-pitch ridge overhang (with clip bar) Mono-pitch ridge overhang (without clip bar)
purlin roof truss roof truss roof truss roof truss roof truss roof
Eaves
141 142 143 144 145 146
Eaves detail with gutter Eaves detail with gutter Parapet eaves gutter detail Overhanging eaves (with clip bar) Overhanging eaves (without clip bar) Valley gutter detail
purlin roof truss roof truss roof truss roof truss roof truss roof
Ridge
161 162 163 164 165 166 167 168
Verge Verge Abutment to parapet Verge with Kalzip® transition sheet Cantilevered verge Cantilevered verge with steel plate bracket Curved verge Curved verge with Kalzip® transition sheet
purlin roof truss roof truss roof truss roof truss roof purlin roof truss roof truss roof
Construction details rafter roof Construction 201 202
Roof construction with rafter insulation Roof construction Kalzip® AF with intermediate rafter insulation
rafter roof rafter roof
Ridge
221 222 223 224
Ridge with fixed point Abutment ridge to parapet Cantilevered ridge with clip bar Overhanging ridge with cantilever rafter
rafter rafter rafter rafter
roof roof roof roof
Eaves
241 242 243 244 245
Dripping eaves Cantilevered dripping eaves with clip bar Overhanging ridge with cantilever rafter Dripping eaves Kalzip® AF Dripping eaves Kalzip® AF/ventilated masonry
rafter rafter rafter rafter rafter
roof roof roof roof roof
Ridge
261 262 263 264
Overhanging Overhanging Overhanging Overhanging
rafter rafter rafter rafter
roof roof roof roof
verge verge with Kalzip® transition sheet verge with Kalzip® AF round verge
Supplementary construction details Hip
301 302
Hip with ridge closure Welded hip with Kalzip® transition sheet
purlin roof purlin roof
Groove
303 304 305
Groove with gutter Groove with Kalzip® AF Groove on building unit with expansion member
rafter roof rafter roof
Contents
Roof-light
311 312 313 314 315
Domed roof-light roofing frame Cross-section roof-light with flat flange - roofing frame Cross-section roof-light with flat flange Cross-section roof-light with Kalzip® roofing frame Longitudinal roof-light with Kalzip® roofing frame
truss truss truss truss
roof roof roof roof
Roof lights
321 322 323 324
Lighting Lighting Lighting Lighting
truss truss truss truss
roof roof roof roof
Joints
331 332
Curved roof with welded ridge jolt Curved roof with sealed lateral jolt
truss roof truss roof
Stepped roofs
341 342
Lowered dripping eaves Lowered verge
rafter roof rafter roof
Expansion joint
351
Expansion joint Kalzip®
truss roof
Ridge
361 362 363
Ridge flashing - cantilevered Sliding ridge - Duo-pitch roof Ventilated ridge
truss roof rafter roof
row row row row
connection, below gable end connection, below gable end connection, below gable end joint - lateral
Construction details Kalzip NatureRoof® Ridge
401 402 403
Duo-pitch ridge Mono-pitch ridge Mono-pitch roof with attic
purlin roof truss roof truss roof
Eaves
411 412
Dripping eaves detail with gutter Dripping eaves with parapet
purlin roof truss roof
Verge
421 422 423
Verge Verge with parapet Verge with Kalzip® transition sheet
purlin roof truss roof truss roof
Additions
431 432 433 434
Installation and shearing protection Domed rooflight Internal box gutter thermally insulated Curved roof with welded ridge jolt
truss truss truss truss
roof roof roof roof
Construction details Kalzip Duo® and Kalzip DuoPlus® Construction
Additions
501 502 503 504 505 506
Roof Roof Roof Roof Roof Roof
construction construction construction construction construction construction
511 521 531
Duo-pitch ridge Dripping eaves Verge
with trapezoidal steel deck with aerated concrete roof slaps with upper insulation intermediate rafter insulation with trapezoidal steel profile (structural deck)
truss roof truss roof purlin roof rafter roof rafter roof truss roof purlin roof truss roof truss roof
Construction detail 101 Kalzip® deck roof system - rafter roof Cross-section
Compound clip* (diagonally installed) Alternative: Al-clip with thermal barrier Kalzip® Kalzip® rock wool insulation Kalzip® vapour control layer
Structural deck Rafter
Horizontal section
Compound clip* (diagonally installed) Alternative: Al-clip with thermal barrier Kalzip® Kalzip® rock wool insulation Kalzip® vapour control layer
Structural deck Rafter * Compound clips are not available in all sizes.
Detail 101
01.02.04 scale 1:10
Construction detail 102 Kalzip® deck roof system - purlin roof Cross-section Compound clip* Alternative: Al-clip with thermal barrier Top-hat sub-purlin Kalzip® Kalzip® rock wool insulation Kalzip® vapour control layer
Structural deck Purlin Rafter
Horizontal section Compound clip* Alternative: Al-clip with thermal barrier Top-hat sub-purlin Kalzip® Kalzip® rock wool insulation Kalzip® vapour control layer
Structural deck Purlin Rafter * Compound clips are not available in all sizes.
01.02.04 scale 1:10
Detail 102
Construction detail - Kalzip® liner-deck roof system - purlin roof 121 Duo-pitch ridge
Type of fixed point to be determined by calculation
Alternative: Fixed point clip Al-clip with thermal barrier
Ridge flashing
Fixed point clip Compound clip*
Spacer profile Fixing of ridge flashing: max. distance 400 mm, only into ridge closure
Filler block
Ridge turn up
≥ 100
Ridge closure
≥ 70
Kalzip®
Ridge flashing
Liner deck
Insulation - rigid**
Top-hat sub-purlin
Kalzip® vapour control layer
Purlin
Kalzip rock wool insulation
Rafter
®
Inner skin flashing
* Compound clips are not available in all sizes. ** Special precautions must be taken when soft thermal insulation is used to prevent penetration.
Detail 121
01.02.04 scale 1:5
Construction detail - Kalzip® deck roof system - rafter roof 122 Duo-pitch ridge
Type of fixed point to be determined by calculation
Ridge flashing Alternative: Fixed point clip Al-clip with thermal barrier Fixing of ridge flashing: max. distance 400 mm, only into ridge closure
Fixed point clip Compound clip*
Spacer profile Ridge turn up
Filler block Ridge closure
≥ 100
≥ 70
Kalzip®
Kalzip® rock wool insulation Insulation - rigid**
Structural deck
Kalzip® vapour control layer
Rafter
* Compound clips are not available in all sizes. ** Special precautions must be taken when soft thermal insulation is used to prevent penetration.
01.02.04 scale 1:5
Detail 122
Construction detail - Kalzip® deck roof system - rafter roof 123 Mono-pitch ridge
Type of fixed point to be determined by calculation
Al-Fixed point clip with thermal barrier Alternative: Compound clip*
Kalzip® Kalzip® rock wool insulation
Filler block
Spacer profile
Fixing of ridge flashing: max. distance 400 mm, only into Ridge closure
Ridge turn up Ridge flashing Retainer
Ridge closure
Kalzip® vapour control layer
Insulation - rigid**
Slosure profile to structural liner tray Sealing strip 2x
Structural deck
Kalbau® trapezoidal deck
Internal closure flashing
Structural liner tray
Insulation
Sealing strip
Thermal isolation strip
* Compound clips are not available in all sizes. ** Special precautions must be taken when soft thermal insulation is used to prevent penetration.
Detail 123
01.02.04 scale 1:5
Construction detail - Kalzip® deck roof system - rafter roof 124 Abutment ridge to parapet
Ridge flashing Spacer profile Ridge turn up
Coping system Timber bearer
Fixed point clip Compound clip* Alternative: Al-clip with thermal barrier
Coping bracket
Filler block Fixing of ridge flashing: max. distance 400 mm; not into standing seam
≥ 100
Ridge closure
≥ 70
Kalzip®
Kalzip® rock wool insulation Structural deck Insulation - rigid** Kalzip vapour control layer ®
Internal closure flashing Sealing strip
* Compound clips are not available in all sizes. ** Special precautions must be taken when soft thermal insulation is used to prevent penetration.
01.02.04 scale 1:5
Detail 124
Detail 125 Internal closure flashing
Structural top hat supports
Kalzip® vapour control layer
Structural deck
on by calculati
Timber spacer
determined
on by calculati determined
Insulation
Structural liner tray
Kalbau®
Sealing strip 2x
Thermal isolation strip
Closure profile to structural liner tray
Kalbau®
) (max. 1500
Ridge closure
Ridge turn up
Spacer profile
Al-clip bar
Kalzip® rock wool insulation
Flashing
Filler block
Kalzip®
Fixed point to be determined by calculation Fixing of ridge flashing: max. distance 400 mm, not into standing seam
Construction detail - Kalzip® deck roof system - rafter roof 125 Mono-pitch ridge overhang (with clip bar)
01.02.04 scale 1:5
01.02.04 scale 1:5 Internal closure flashing
Structural deck
Kalzip® vapour control layer
Timber supports
Kalzip® rock wool insulation
Kalzip®: Length min. 5,0 m
Timber ridge bearer
AL-fixed point clip length to be determined by calculation
) (max. 1000
Insulation
Structural liner tray
Kalbau® trapezoidal profile
Sealing strip 2x
Thermal isolation strip
Closure profile to structural liner tray
Angle with sealing strip
on by calculati determined
‘Eaves’ filler block
Drip angle
‘Eaves’ filler block
Construction detail - Kalzip® deck roof system - rafter roof 126 Mono-pitch ridge overhang (without clip bar)
Detail 126
Construction detail - Kalzip® liner-deck roof system - purlin roof 141 Eaves detail with gutter
Compound clip*
Alternative
Filler block Drip angle
Closure flashing Timber eaves bearer Timber spacer
Kalzip® Kalzip® rock wool insulation
Sealing strip
Kalzip® vapour control layer Insulation - rigid
Al-clip
Gutter Gutter brackets Closure flashing Liner-deck Purlin Rafter
* Compound clips are not available in all sizes.
Detail 141
01.02.04 scale 1:5
Construction detail - Kalzip® deck roof system - rafter roof 142 Eaves detail with gutter
Kalzip®
Gutter
Insulation rigid
Filler block Drip angle
Timber spacer Kalzip® vapour control layer
Closure flashing Gutter brackets
Kalzip rock wool insulation ®
Timber eaves bearer Al-clip
Thermal isolation strip
Closure profile to structural liner tray
Structural deck
Internal closure flashing
Rafter Sealing strip 2x
Structural liner tray
Insulation
Kalbau® SN 18/76
01.02.04 scale 1:5
Detail 142
Detail 143
Rainwater pipe
Gutter liner outlet
Gutter outlet
Circular sealing strip
Rafter
Structural deck
Kalzip® rock wool insulation
Compound clip* Alternative: Al-clip with thermal barrier
Kalzip® vapour control layer
Insulation - rigid
Kalzip®
Emergency overflow
Filler block
Drip angle
Insulation retainer
Gutter liner (fully sealed)
Insulation - rigid
Gutter
Sealing strip
Closure flashing
Z-Profile
Kalbau® trpezoidal profile
Timber
Coping bracket
Coping system
Construction detail - deck roof system - rafter roof 143 Parapet eaves gutter detail
* Compound clips are not available in all sizes.
01.02.04 scale 1:5
01.02.04 scale 1:5
Kalzip® vapour control layer
Top-hat sub-purlin
Spacer profile
Rafter
Sealing strip 2x
Internal closure flashing
Structural deck
determined by calculation
Drip angle
Kalzip® rock wool insulation
Kalbau® SN 18/76
Insulation
Structural liner tray
Closure profile to structural liner tray
Thermal isolation strip
Kalbau® SN 18/76
determined by calculation (m ax. 1500)
Gutter brackets
Filler block
Gutter
Al-clip bar
Kalzip®
Construction detail - deck roof system - rafter roof 144 Overhanging eaves (with clip bar)
Detail 144
Detail 145 Rafter
Sealing strip 2x
Internal closure flashing
Structural deck
Kalzip® vapour control layer
Timber spacer
Kalzip® rock wool insulation
Kalzip®: Lenght min. 5,0m
Timber eaves bearer
Al-clip length determined by calculation
Kalbau® trapezoidal profile
Insulation
Structural liner tray
Closure profile to structural liner tray
Thermal isolation strip
Gutter brackets
Al-clip: length 200 mm 2 rivets on the small rib
Drip angle
Filler block
Gutter
Construction detail - Kalzip® deck roof system - rafter roof 145 Overhanging eaves (without clip bar)
01.02.04 scale 1:5
01.02.04 scale 1:5
Alternative without timber eaves bearer
Rainwater pipe
Gutter liner outlet
Gutter outlet
Circular sealing strip
Kalzip® rock wool insulation
Kalzip® vapour control layer
Compound clip*
Insulation - rigid
Kalzip®
Closure flashing
Drip angle
Filler block
Gutter liner (fully sealed)
Insulation - rigid
Gutter
Emergency overflow
Closure flashing
Timber spacer
Rafter
Structural deck
Alternative with timber eaves bearer
Timber eaves bearer
Al-clip
Construction detail - Kalzip® deck roof system - rafter roof 146 Valley gutter detail
* Compound clips are not available in all sizes.
Detail 146
Construction detail - Kalzip® liner-deck roof system - purlin roof 161 Verge
Al-clip Tolerance profile
Sealing strip
Gable end channel
Timber verge bearer
Gable end clip
Kalzip®
Verge flashing
Kalzip® rock wool insulation
Retainer flashing Compound clip* Alternative: Al-clip with thermal barrier
Closure flashing Tolerance
Top-hat sub-purlin Kalzip® vapour control layer
Kalzip ® TF 800 R
Liner deck Interal closure flashing
Purlin Rafter
* Compound clips are not available in all sizes.
Detail 161
01.02.04 scale 1:5
Construction detail - Kalzip® deck roof system - rafter roof 162 Verge
Alternative
Verge profile Tolerance
Al-clip
Timber verge bearer
Tolerance profile
Kalzip®
Gable end channel
Kalzip® rock wool insulation
Gable end clip
Compound clip* Alternative: Al-clip with thermal barrier
Verge flashing
Tolerance
Flashing retainer support Kalzip® vapour control layer
Structural deck Sealing strip Rafter * Compound clips are not available in all sizes.
05.05.04 scale 1:5
Detail 162
Construction detail - Kalzip® deck roof system - rafter roof 163 Abutment to parapet
Alternative
Coping system Coping bracket Timber bearer
min. 150
Z-Profil Kalbau® trapezoidal profile
Retainer flashing Kalzip® transition sheet
Verge flashing Gable end clip
Insulation - rigid
Gable end channel Tolerance
Kalzip® Compound clip* Alternative: Al-clip with thermal barrier
Tolerance profile
Kalzip® rock wool insulation Kalzip® vapour control layer Structural deck Insulation - rigid Sealing strip
* Compound clips are not available in all sizes.
Detail 163
01.02.04 scale 1:5
Construction detail - Kalzip® deck roof system - rafter roof 164 Verge with Kalzip® transition sheet
Closure flashing Flashing retainer/support Kalzip® transition sheet Compound clip* Alternative: Al-clip with thermal barrier Kalzip® rock wool insulation Kalzip® vapour control layer Structural deck
Internal closure flashing Sealing strip
Kalzip® TF 800 R
* Compound clips are not available in all sizes.
01.02.04 scale 1:5
Detail 164
Detail 165
Kalbau® SN 18/76
Kalbau® SN 18/76
Insulation
Structural liner tray
Closure profile to structural liner tray
Sealing strip
Thermal isolation strip
Thermal isolation
Top-hat support profile
Structural deck
determined by calculation
Kalzip® vapour control layer
Kalzip® transition sheet
Top-hat support
Kalzip® rock wool insulation
Flashing retainer/support
Rectangular hollow section
Al-clip with thermal barrier
Kalzip®
Construction detail - Kalzip® deck roof system - rafter roof 165 Cantilevered verge
01.02.04 scale 1:5
01.02.04 scale 1:5
Al-clip
Omega profile
Gable end clip
®
Kalbau SN 18/76
Purlin
Thermal isulation
Internal closure flashing
Rafter
Liner-deck
Vapour control layer clamped sealed
Steel plate bracket
Compound clip* Alternative: Al-clip with thermal barrier
Top-hat sub-purlin
Kalzip® vapour control layer
Kalzip® rock wool insulation
Kalzip®
Construction detail - Kalzip® liner-deck roof system - purlin roof 166 Cantilevered verge with steel plate bracket
* Compound clips are not available in all sizes.
Detail 166
Construction detail - Kalzip® deck roof system - rafter roof 167 Curved verge
Curved verge flashing
Perforated closure flashing Flashing retainer/support Gable end clip Gable end channel (curved by slotting) Tolerance profile (in short lenghts)
Convex Kalzip® Kalzip® rock wool insulation Compound clip* Alternative: Al - clip with thermal barrier
Ri Vapour control layer clamped and sealed
Kalzip® vapour control layer Structural deck
Kalbau® SN 18/76
Closure flashing
* Compound clips are not available in all sizes.
Detail 167
01.02.04 scale 1:5
Construction detail - rafter roof 168 Curved verge with Kalzip® - transition sheet
Kalzip® transition sheet - curved
Compound clip* Alternative: Al-clip with thermal barrier
Perforated closure flashing Flashing retainer/support
Kalzip® rock wool insulation Convex Kalzip®
Ri Vapour control layer clamped and sealed Kalbau® SN 18/76
Kalzip® vapour control layer Structural deck Closure flashing
* Compound clips are not available in all sizes.
01.02.04 scale 1:5
Detail 168
Construction detail rafter roof 201 Roof construction with rafter insulation Cross-section Compound clip* Alternative: Al-clip with thermal barrier Timber (min. 10/6) Kalzip®
Timber rater Timber shuttering Kalzip® vapour control layer H Kalzip® rock wool insulation
Longitudinal section Timber (min. 10/6) Compound clip* Alternative: Al-clip with thermal barrier Kalzip®
Timber rater Timber shuttering Kalzip® vapour control layer H Kalzip® rock wool insulation
Detail 201
* Compound clips are not available in all sizes.
01.02.04 scale 1:10
Construction detail rafter roof 202 Roof construction Kalzip® AF with intermediate rafter insulation Cross-section Compound clip E10 (diagonally installed) Alternative: Al-clip L10 Precovering (open for diffusion) Kalzip® AF Timber shuttering
Timber rater Kalzip® rock wool insulation Kalzip® vapour control layer Timber lathing Interior lining layer
Longitudinal section Kalzip® AF Compound clip E10 (distributed installed) Alternative: Al-clip L10 Precovering (open for diffusion)
Timber rater Timber shuttering Kalzip® rock wool insulation Kalzip® vapour control layer Timber lathing Interior lining layer
01.02.04 scale 1:10
Detail 202
Detail 221
Kalzip® rock wool insulation
Thermal insulation - rigid
Ridge closure
Filler block
Type of fixed point to be determined by calculation * Compound clips are not available in all sizes.
Kalzip® vapour control layer H
Timber shuttering
Timber rafter
Fixing of ridge flashing: max. distance 400 mm, into ridge closure
Fixed point clip determined by calculation Compound clip*
Timber
Fixed point clip determined by calculation; Al-clip ≥ 70
Ridge flashing
Ridge turn out
0 ≥ 10
Kalzip®
Spacer profile
Construction detail - rafter roof 221 Ridge with fixed point
01.02.04 scale 1:5
Construction detail - rafter roof 222 Abutment ridge to parapet
Type of fixed point to be determined by calculation
Coping system Timber eaves bearer Coping bracket
Ridge flashing Spacer profile Ridge turn up Kalzip® rock wool insulation Timber Fixed point clip determined by calculation; Compound clip* Filler block
≥
100
≥ 70
Ridge closure Kalzip®
Clip track with sealing strip Timber rafter Timber shuttering Kalzip® vapour control layer H Thermal insulation - rigid
01.02.04 scale 1:5
* Compound clips are not available in all sizes.
Detail 222
Detail 223
ulati
on
Timber rafter
Timber shuttering
Kalzip® vapour control layer H
calc d by e n i rm dete
Al-clip bar
Kalzip®
Kalzip® rock wool insulation
Timber supports
Filler block rm dete
ined
by
0 . 150
)
Drip angle with sealing strip
Filler block
Panel
Insulation
Alternative
Clipping track with sealing strip
Stripping felt
Kalbau® SN 18/76
Spacer profile
Closure flashing
Filler block
Ridge closure
(max tion a l u calc
Construction detail - rafter roof 223 Cantilevered ridge with clip bar
01.02.04 scale 1:5
01.02.04 scale 1:5
Timber rafter
Timber shuttering
Kalzip® vapour control layer H
Kalzip® rock wool insulation
Timber spacer
Kalzip®
Drip angle
Clipping track with sealing strip
Ridge closure
Cantilever rafter
Timber shuttering
Insulation
Filler block
Flashing
Timber bearer
Fixed point clip Al-clip
Construction detail - rafter roof 224 Overhanging ridge with cantilever rafter
Detail 224
Construction detail - rafter roof 241 Dripping eaves
Gutter Filler block Drip angle Closure flashing Gutter brackets Closure flashing Flashing retainer Timber eaves bearer Timber spacer Al-clip
20
Kalzip®
Timber rafter Timber shuttering Kalzip® vapour control layer H Thermal insulation - rigid Kalzip® rock wool insulation
Detail 241
01.02.04 scale 1:5
01.02.04 scale 1:5
Gutter
Gutter brackets
Clipping track with sealing strip
Connecting angle
Kalbau® SN 18/76
y ed b rmin e t e d
500) ax. 1 m ( n latio calcu
Drip angle
Filler block
Kalzip
®
Al-clip bar
Timber
Timber spacer
Kalzip® rock wool insulation
ulati
Timber rafter
Timber shuttering
Kalzip® vapour control layer H
Timber supports
alc by c ned i m r dete
on
Construction detail - rafter roof 242 Cantilevered eaves with clip bar
Detail 242
Detail 243 Sealing strip
Closure profile
Cantilever rafter
Kalzip®
Al-clip
Timber eaves bearer
Closure flashing
Drip angle
Filler block
Gutter
Timber rafter
Timber shuttering
Kalzip® vapour control layer H
Kalzip® rock wool insulation
Timber spacer
Construction proposal rafter roof 243 Overhanging dripping eaves with cantilever rafter
01.02.04 scale 1:5
Alternative
01.02.04 scale 1:5 Gutter
Filler block
Drip angle
Closure flashing
Compound clip E10
Exposed shuttering
Kalzip® AF
Coping rafter
Embeding gutter brackets
Exposed shuttering
Al-clip
Kalzip®
Precovering (open for diffusion)
Timber shuttering
Timber rafter
Kalzip® rock wool insulation
Timber lathing
Interior lining layer
Kalzip® vapour control layer
Clipping track with sealing strip
Construction detail - rafter roof 244 Dripping eaves Kalzip® AF
Detail 244
Detail 245
Kalzip® AF
Exposed shuttering
Perforatet metal sheet
Gutter
Filler block
Drip angle
Closure flashing
Compound clip E10
Precovering (open for diffusion)
Timber shuttering
Timber rafter
Kalzip® rock wool insulation
Timber lathing
Interior lining layer
Kalzip® vapour control layer
Clipping track with sealing strip
Construction detail - rafter roof 245 Dripping eaves Kalzip® AF/ventilated masonry
01.02.04 scale 1:5
01.02.04 scale 1:5 Tolerance profile Verge flashing
Kalzip®
Al-clip
Timber spacer
Timber rafter
Timber shuttering
Kalzip® vapour control layer H
Clipping track with sealing strip
Flashing retainer - two-part
Cantilever purlin
Timber shuttering
Gable end channel
Kalzip® rock wool insulation
determined by calculation
Gable end clip
Purlin
Construction detail - rafter roof 261 Overhanging verge
Detail 261
Detail 262 Timber shuttering
Al-clip
Timber spacer
Timber rafter
Timber shuttering
Kalzip® vapour control layer H
Clipping track with sealing strip
determined by calculation
Kalzip® transition sheet
Kalzip®
Cantilever purlin
Flashing retainer
Kalzip® rock wool insulation
Construction detail - rafter roof 262 Overhanging verge with Kalzip® transition sheet
01.02.04 scale 1:5
01.02.04 scale 1:5
Kalzip® rock wool insulation
Kalzip® vapour control layer H
Timber lathing
Interior lining layer
Clipping track with sealing strip
Timber shuttering
Exterior rafter lower
Exposed shuttering
Kalzip® AF transition sheet
Compound clip E10 Alternative: Al-clip
Precovering (open for diffusion)
Flashing retainer
Kalzip® AF profile sheet
Construction detail - rafter roof 263 Overhanging verge Kalzip® AF
Detail 263
Detail 264
Timber spacer
Timber rafter
determined by calculation
Kalzip® rock wool insulation
Timber shuttering
Kalzip® vapour control layer H
Clipping track with sealing strip
Kalzip®
Al-clip
Cantilever purlin
Alternative
Gable end clip Curved gable end channel
Tolerance profile (in short lenghts)
Curved verge flashing
Flashing retainer
Kalzip® transition sheet
Construction detail - rafter roof 264 Overhanging round verge
01.02.04 scale 1:5
Construction detail - purlin roof 301 Hip with ridge closure
Type of fixed point to be determined by calculation Ridge turn up
Spacer profile
Fixed point clip Compound clip*
Ridge flashing Filler block
≥ 100
≥ 70
Ridge closure Kalzip®
Insulation - rigid
Hip purlin
Kalzip vapour control layer
Top-hat sub-purlin
Kalzip rock wool insulation
Structural liner-deck
®
®
Fixing of ridge flashing: max. distance 400 mm, not into standing seam
Ridge flashing Spacer profile Filler block Ridge closure Kalzip®
* Compound clips are not available in all sizes.
01.02.04 scale 1:5
Detail 301
Construction detail - purlin roof 302 Welded hip with Kalzip® transition sheet
Fixed point clip Compound clip* Kalzip® Welding seam Kalzip® welding basis Kalzip® transition sheet
Insulation - rigid (not inflammable) Kalzip® vapour control layer
Hip purlin Structural deck Top-hat sub-purlin
Kalzip® rock wool insulation
Type of fixed point to be determined by calculation
Kalzip® transition sheet Welding seam Kalzip®
* Compound clips are not available in all sizes.
Detail 302
01.02.04 scale 1:5
01.02.04 scale 1:5
Kalzip® vapour control layer H
Timber shuttering
Timber rafter
Timber spacer
Kalzip® rock wool insulation
Thermal insulation - rigid
Compound clip E10
Timber eaves bearer
Filler block
Drip angle
Kalzip®
Flashing
Construction detail - rafter roof 303 Groove with gutter
Detail 303
Detail 304
Compound E10
Internal lining layer
Timber lathing
Kalzip® vapour control layer
Coping timber rafter
Kalzip® rock wool insulation
Timber shuttering
Precovering (open for diffusion)
Filler block
Drip angle
Kalzip® AF
Gutter metal sheet
Construction detail 304 Groove with gutter Kalzip® AF
01.02.04 scale 1:5
Construction detail 305 Groove on building unit with expansion member
Wall connection profile sealed Cantilever metal sheet Flashing
Expansion member (1-head) Insulation - compressible Welding joint
approx. 500
Kalzip® Kalzip® transition sheet
01.02.04 scale 1:5
Detail 305
Construction detail 311 Domed roof-light roofing frame
Domed roof-light Flat flange-roofing frame (to weld)
Light cupola-skylight Attaching frame Flat flange-roofing frame Upper conecting frame
Domed roof-light Kalzip® roofing frame (standing seam)
Flashing Attaching frame Kalzip® roofing frame Upper conecting frame Light cupola-skylight
Detail 311
01.02.04 scale 1:5
01.02.04 scale 1:5
Rafter
Roofing frame
* Compound clips are not available in all sizes. ** Domed rooflight: complete with curb, light dome, cantilever metal sheet and frame
Kalzip® rock wool insulation
Insulation - rigid (not inflammable)
min. 200
Flashing profile
Order size
x x
Insulation
Welding seam
Kalzip®
Compound clip*
Kalzip® vapour control layer
100
Longitudinal beam determined by calculation
min. 200
x
Height
Structural deck
Kalzip® welding basis
Flat flange roofing frame
Upper connecting frame
Domed roof-light**
l = distance fixed point - domed roof-light [mm] x = sliding path = l/1000 + min. 5 mm x min. = 20 mm
Construction detail 312 Cross-section roof-light with flat flange - roofing frame
Detail 312
Construction detail 313 Cross-section roof-light with flat flange
Domed roof-light** Upper connecting frame Flat flange - roofing frame Welding seam Kalzip® welding basis Cut Kalzip® sheet
Height
Compound clip*
100
Kalzip®
Ordering size
Kalzip® rock wool insulation Kalzip® vapour control layer Cross beam determined by calculation Insulation - rigid (not inflammable) Structural deck Framing profile Roofing frame
* Compound clips are not available in all sizes. ** Domed rooflight: complete with curb, light dome, cantilever metal sheet and frame
Detail 313
01.02.04 scale 1:5
01.02.04 scale 1:5
Rafter
Roofing frame
Roofing frame
Longitudinal profile determined by calculation
100
Ordering size
Height
Structural deck
Fixed point clip
Ridge closure + filler block
Ridge flashing
Ridge turn up
Spacer profile
Upper connecting frame
Domed roof-light**
Insulation - rigid (not inflammable)
Kalzip® welding basis
min. 200
* Compound clips are not available in all sizes. ** Domed rooflight: complete with curb, light dome, cantilever metal sheet and frame
Kalzip® rock wool insulation
Kalzip® vapour control layer
x x
Kalzip® roofing frame
Welding seam
Kalzip®
Compound clip*
l = distance fixed point - domed roof-light [mm] x = sliding path = l/1000 + min. 5 mm x min. = 20 mm
Construction detail 314 Cross-section roof-light with Kalzip® roofing frame
Detail 314
Construction detail 315 Longitudinal roof-light with Kalzip® roofing frame
Domed roof-light** Upper connecting frame Kalzip® roofing frame
Height
Compound clip*
100
Kalzip®
Ordering size
Kalzip® rock wool insulation Profile determined by calculation Kalzip® vapour control layer Structural deck Insulation - rigid (not inflammable) Flashing profile Roofing frame
* Compound clips are not available in all sizes. ** Domed rooflight: complete with curb, light dome, cantilever metal sheet and frame
Detail 315
01.02.04 scale 1:5
Construction detail 321 Lighting row connection, below gable end · truss roof
l = distance fixed point - domed roof-light [mm] x = sliding path = l/1000 + min. 5 mm x min. = 20 mm
Cantilever metal sheet Flashing Kalzip® welding basis Welding seam Compound clip*
Kalzip®
x x
min. 200
Insulation compressible Insulation Lighting row frame Sealing strip
Structural deck
Kalzip® rock wool insulation
Trimmer beam Rafter
Kalzip® vapour control layer Insulation - rigid (not inflamable)
* Compound clips are not available in all sizes.
01.02.04 scale 1:5
Detail 321
Construction detail 322 Lighting row connection, below gable end · truss roof
Spacer profile Ridge flashing Ridge closure + filler block Fixing of ridge flashing: max. distance 400 mm, not into standing seam Kalzip® Fixed point clip Compound clip*
Insulation Lighting row frame Sealing strip
Kalzip® rock wool insulation
Structural deck Trimmer beam
Insulation - rigid
Rafter
Kalzip vapour control layer ®
* Compound clips are not available in all sizes.
Detail 322
01.02.04 scale 1:5
Construction detail 323 Lighting row connection, below gable end · truss roof
l = distance fixed point - domed roof-light [mm] x = sliding path = l/1000 + min. 5 mm x min. = 20 mm
Cantilever metal sheet Ridge flashing Kalzip® welding basis Welding seam Kalzip® Compound clip* x x
Insulation compressible
min. 200 Insulation Lighting row frame Sealing strip
Kalzip® rock wool insulation
Structural deck Trimmer beam
insulation - rigid (not inflammable)
Rafter
Kalzip® vapour control layer
* Compound clips are not available in all sizes.
01.02.04 scale 1:5
Detail 323
Detail 324
* Compound clips are not available in all sizes.
Tolerance profile
Tolerance
Gable end channel
Gable end clip
Verge flashing
Alternative
Sealing strip
Lighting row frame
Insulation
min. 150
Trimmer beam
Insulation - rigid
Structural deck
Kalzip® vapour control layer
Kalzip® rock wool insulation
Kalzip® transition sheet
Cantilever metal sheet
Compound clip*
Kalzip®
Construction detail - rafter roof 324 Lighting row joint - lateral
01.02.04 scale 1:5
01.02.04 scale 1:5 Welded joint
Rafter
Structural deck
®
Kalzip
Alternative: Fixed point clip Al-clip with thermal barrier
Kalzip® vapour control layer
Insulation - rigid (not inflammable)
Kalzip® welding basis
Type of fixed point to be determined by calculation
100
Ri
Kalzip ®
* Compound clips are not available in all sizes.
Fixed point clip Compound clip* Kalzip® rock wool insulation
Kalzip®
Construction detail - trussed roof 331 Curved roof with welded ridge jolt
Detail 331
Detail 332
Approved aluminiumseal rivet Ø 4,8 mm with stainless steel bolt
Rafter
Seal scheme for Kalzip® with two beads
Ri
Structural deck
Kalzip® vapour control layer
®
Kalzip rock wool insulation
Kalzip®
200
Silic
ping
ours
Silicone
200 one
rlap
r Ka lzip ® c
Ove
uppe e
Incl inat min
100
ion: . 2, 9°
low er lzip ® co urs
e
* Compound clips are not available in all sizes.
Compound clip*
Ka
Construction detail - rafter roof 332 Curved roof with sealed lateral jolt
01.02.04 scale 1:5
01.02.04 scale 1:5
Kalzip®
Al-clip
Kalzip® rock wool insulation
Kalzip® vapour control layer H
Ridge closure + filler block
Flashing
Drip angle
Filler block
Plank (min. 10/6)
Gutter
Closure flashing
Timber shuttering
Visible shuttering
Timber rafter
Flashing retainer
Compound clip*
Kalzip® rock wool insulation Insulation - rigid
* Compound clips are not available in all sizes.
Construction detail - rafter roof 341 Lowered dripping eaves
Detail 341
Detail 342
Kalzip®
Kalzip® rock wool insulation
Compound clip*
Kalzip® transition sheet
Supporting profile
Kalzip® vapour control layer H
Timber
Timber rafter
External rafter lower
Al-clip
Visible shuttering
Timber shuttering
Kalzip® transition sheet
Insulation - rigid
Flashing retainer
* Compound clips are not available in all sizes.
Construction detail - rafter roof 342 Lowered verge
01.02.04 scale 1:5
Construction detail -rafter roof 351 Expansion joint Kalzip®
Flashing
Section A-A
Holder
* Compound clips are not available in all sizes.
Flashing retainer
Gable end clip Flashing
Gable end channel
Holder
Compound clip*
Flashing retainer
A
Strain
A Kalzip®
Strain
Kalzip® rock wool insulation
Structural deck Rafter
Kalzip® vapour control layer
01.02.04 scale 1:2,5
Flat metal strip (fixed on one side)
Detail 351
Fixing of ridge flashing in ridge closure: max. distance 400 mm; not into standing seam
Detail 361 2 rows sealing matter
Fixing within the overlapping only for the lower ridge flashing
Kalzip®
Ridge turn up
Ridge closure
Spacer profile
Filler block
Ridge flashing L = max. 6,0 m
Construction detail 361 Ridge flashing - cantilevered
02.07.03 scale 1:5
Construction detail - rafter roof 362 Sliding ridge - Duo-Pitch roof
Cross-section scale 1:1
Ridge flashing Sliding member Fixing of ridge flashing on sliding member: max. distance 400 mm; not into standing seam
Kalzip® Clip Sliding potential between Kalzip® and sliding unit
Reinforcing profile
l = distance ridge to fixed point [mm] x = sliding path = l/1000 + min. 5 mm x min. = 20 mm
Ridge turn up Ridge flashing Compound clip*
Fixing of ridge flashing on sliding member: max. distance 400 mm; not into standing seam
Sliding member
≥ 100+x
≥ 70
Filler block Ridge closure Kalzip®
Kalzip® rock wool insulation Insulation - rigid
Structural deck
Kalzip® vapour control layer
Rafter
* Compound clips are not available in all sizes.
01.02.04 scale 1:10
Detail 362
Construction detail - Rafter Roof 363 Ventilated ridge
Ridge turn up
Ridge flashing
Kalbau® structural deck*
Spacer profile
Perforated sheet angle 50/50
Filler block
Fixed point clip Al-clip
≥100
Ridge closure Fixing of ridge flashing: max. distance 400 mm
Kalzip®
Rafter Purlin
* Kalbau® structural deck (trapezoidal profile 50/167) l = 150 mm/construction width = 833 mm
Detail 363
01.02.04 scale 1:5
01.02.04 scale 1:5
≥100
®
Structural deck
Purlin
Kalzip rock wool insulation
≥70
Top-hat sub-purlin
≥100
Fixed point Compound clip*
Ridge flashing
Spacer profile
Ridge turn up
Kalzip vapour control layer ®
Insulation - rigid
Al-beam claw (joint)
Ridge terminal
KD 33 linear drainage system
NDS 60 plant substrate
Planting
* Compound clips are not available in all sizes.
Kalzip® 65/333
Ridge closure
Filler block
Construction detail - purlin roof 401 Duo-Pitch ridge
Detail 401
Construction detail - rafter roof 402 Mono-Pitch ridge
NDS 60 plant substrate
Ridge termination Al-beam claw (joint)
KD 33 linear drainage system
Kalzip® 65/333 Ridge closure
Kalzip® rock wool insulation
Filler block Kalzip® vapour control layer
Ridge flashing
Planting
Spacer profile ≥100
10
Ridge turn up
Insulation - rigid
Closure profile to structural liner tray Sealing strip 2x
Al-fixed point clip with thermal barrier Alternative: Compound clip*
Rafter
Structural deck
Kalbau® structural deck
Internal closure flashing
Structural liner tray
Insulation
Sealing strip
Thermal isolation strip * Compound clips are not available in all sizes.
Detail 402
01.02.04 scale 1:5
Construction suggestions Kalzip NatureRoof® 403 Monopitch roof with attic · truss roof
* Compound clips are not available in all sizes.
Kalzip® 65/333 Ridge turn up Spacer profile Ridge flashing Planting Coping system
NDS 60 plant substrate
Timber KD 33 linear drainage system
Coping bracket
Ridge termination flashing Al-beam claw (joint) Filler block Ridge closure ≥100
≥70
10
≥100
Kalzip® rock wool insulation
Fixed point clip compound clip* Structural deck
Insulation - rigid Kalzip® vapour control layer Rafter
01.02.04 scale 1:5
Internal closure flashing Sealing strip
Detail 403
Construction detail - purlin roof 411 Dripping eaves detail with gutter
Filler block Drip angle Planting NDS 60 plant substrate KD 33 linear drainage system Eaves termination flashing
Closure flashing Timber eaves bearer Timber spacer
Al-beam claw joint Kalzip® 65/333
≥100 Sealing strip Clip
Kalzip® rock wool insulation Kalzip® vapour control layer
Gutter Gutter brackets Flashing
Insulation rigid Purlin Structural deck Rafter
Detail 411
01.02.04 scale 1:5
01.02.04 scale 1:5
Gutter liner outlet
Planting
Rainwater pipe
Gutter outlet
Circular sealing strip
Rafter
Structural deck
10
KD 33 linear drainage system
Compound clip*
Kalzip® rock wool insulation
NDS 60 plant substrate
Al-beam claw (joint)
Eaves termination flashing
Kalzip® vapour control layer
Insulation - rigid
≥100
Emergency owerflow
Filler block
* Compound clips are not available in all sizes.
Inferior steel gutter
Insulation - rigid
Gutter
Sealing strip
Closure profile
Z-profile
Kalbau® structural deck
Timber bearer
Flashing Drip angle
Coping bracket
Kalzip® 65/333
Coping system
Construction detail - rafter roof 412 Dripping eaves with parapet
Detail 412
Construction detail - purlin roof 421 Verge
Sealing strip Timber verge bearer Al-clip
Kalzip®
Tolerance profile
Kalzip® rock wool insulation
Gable end channel
Top-hat sub-purlin Verge termination flashing
Gable end clip
Al-beam claw (joint)
Verge flashing
Compound clip* Retainer flashing Planting
Perforated closure flashing Tolerance
Kalzip® TF 800 R
NDS 60 plant substrate KD 33 linear drainage system Kalzip® vapour control layer Structural deck Internal closure flashing Purlin * Compound clips are not available in all sizes.
Detail 421
Rafter
01.02.04 scale 1:5
Construction detail - rafter roof 422 Verge with parapet
Coping system Coping bracket Timber bearer
Planting NDS 60 plant substrate
Z-profile Kalbau® structural deck
KD 33 linear drainage system Al-beam claw (joint)
Flashing retainer Verge termination flashing Verge flashing Gable end clip
Kalzip® 65/333
Gable end channel
10
Tolerance
Tolerance profile
Compound clip* Kalzip® rock wool insulation Kalzip® vapour control layer Structural deck Insulation - rigid Sealing strip * Compound clips are not available in all sizes.
01.02.04 scale 1:5
Detail 422
Construction detail - rafter roof 423 Verge with Kalzip® transition sheet
Perforated closure flashing Retainer flashing Kalzip® - transition sheet Compound clip* Alternative: Al-clip with thermal barrier Kalzip® 65/333 Kalzip® rock wool insulation Kalzip® vapour control layer
10
Structural deck
Internal closure flashing Sealing strip
Kalzip® TF 800 R
Al-beam claw (joint) Verge termination flashing KD 33 linear drainage system NDS 60 plant substrate Planting
* Compound clips are not available in all sizes.
Detail 423
01.02.04 scale 1:5
Construction suggestions Kalzip NatureRoof® Additions 431 Installation and shearing protection· truss roof
DN ≤ 5°
Compound clip*
NDS 60 Plant substrate KD 33 linear drainage system
Planting Kalzip® 65/333 Mounting lock
Rafter Structural deck Thermal insulation
DN > 5°
NDS 60 Plant substrate Compound clip*
Kalzip® vapour control layer KD 33 linear drainage system Mounting lock
Planting Kalzip® 65/333 Shearing lock Al-beam claw (joint)
Draina
ge
Rafter Structural deck Thermal insulation
Kalzip® vapour control layer * Compound clips are not available in all sizes.
01.02.04 scale 1:5
Detail 431
Construction suggestions Kalzip NatureRoof® Additions 432 Domed rooflight · truss roof
I = distance fixed point - domed rooflight (mm) x = sliding path = I/1000 + min. 5 mm x min. = 20 mm
KD 33 linear drainage system Domed rooflight** NDS 60 plant substrate Cantilever metal sheet Planting Flat flange-framing Ridge terminal Al-beam claw (joint)
Kalzip® welding basis
Height of the flange
Kalzip® welded
≥100
x x
100
10
min. 200
Order size
Compound clip*
Structural deck Longitudinal beam determined by calculation
Kalzip® vapour control layer
Flashing profile
Kalzip® rock wool insulation
Roofing frame
Insulation - rigid (not inflammable)
Rafter
* Compound clips are not available in all sizes. ** Roof light: complete with curb, roof-light, flange sheet and framing
Detail 432
01.02.04 scale 1:5
01.02.04 scale 1:5 ≥100
Alternative without timber eaves bearer
Rainwater pipe
Gutter outlet Gutter liner outlet
Circular sealing strip
Planting
Closure flashing
Al-clip
Eaves termination flashing
Al-beam claw (joint)
Rafter
Timber spacer
Timber eaves bearer
Structural deck
* Compound clips are not available in all sizes.
Alternative with timber eaves bearer
KD 33 linear drainage system
NDS 60 plant substrate
Emergency overflow
Lower steel gutter (with sealing lateral jolt)
Insulation - rigid
Gutter
Drip angle Framing metal
Filler block
Kalzip® rock wool insulation
Kalzip® vapour control layer
Compound clip*
Insulation - rigid
Kalzip® 65/333
Construction detail - rafter roof 433 Internal box gutter thermally insulated
Detail 433
Detail 434
* Compound clips are not available in all sizes.
Alternative: fixed point clip Al-clip with thermal barrier
Kalzip® vapour control layer
Weleded joint
Rafter
Structural deck
®
Kalzip
Insulation - rigid (not inflammable)
Kalzip® welding basis
Type of fixed point to be determined by calculation
100
Planting
NDS 60 plant substrate
KD 33 linear drainage system
Ri
Kalzip ®
Kalzip®
Kalzip® rock wool insulation
Compound clip*
Construction detail - rafter roof 434 Curved roof with welded ridge joint
01.02.04 scale 1:5
Construction detail - rafter roof Kalzip DuoPlus® 501 Roof construction with trapezoidal steel deck
Kalzip® Kalzip® rock wool insulation DuoPlus clip DuoPlus track 45° direction of span TRP Insulation - rigid h = 100 mm
Kalzip® vapour control layer Structural deck Rafter
01.02.04
Detail 501
Construction detail - rafter roof Kalzip DuoPlus® 502 Roof construction with aerated concrete roof slabs
Kalzip® Kalzip® rock wool insulation DuoPlus clip DuoPlus track 45° direction of span of roof slabs Insulation - rigid h = 100 mm
Kalzip® vapour control layer Aerated concrete roof slabs Rafter
Detail 502
01.02.04
Construction detail - purlin roof Kalzip DuoPlus® 503 Roof construction
Kalzip®
DuoPlus Clip
Kalzip® rock wool insulation
DuoPlus track 90° to direction of span Insulation - rigid h = 100 mm
Purlin Kalzip® vapour control layer Structural deck
01.02.04
Detail 503
Construction detail - rafter roof Kalzip DuoPlus® 504 Roof construction with upper insulation
Kalzip®
DuoPlus Clip
Kalzip rock wool insulation
DuoPlus track 90° to the rafter, fixing into rafter
®
Insulation - rigid h = 100 mm
e≤ 0,8 0
m
Kalzip® vapour control layer H Timber shuttering Timber rafter
* When exceeding the maximum rafter distance e ≤ 0,80m, place DuoPlus track 45° to the rafter and fix it in the shuttering. (length of span according to statics)
Detail 504
01.02.04
Construction detail - rafter roof Kalzip DuoPlus® 505 Roof construction intermediate rafter insulation
Kalzip®
DuoPlus Clip
Kalzip rock wool insulation
DuoPlus track 90° to the rafter, fixing into rafter
®
e≤ 0,8 0
m
Timber rafter Kalzip® vapour control layer Timber lathing Interior lining layer
01.02.04
Detail 505
Construction proposal rafter roof Kalzip Duo® 506 Roof construction with trapezoidal steel profile (structural deck)
Kalzip® Kalzip® rock wool insulation DuoPlus Clip DuoPlus track 45° to direction of span Strip insulation - rigid h = 100 mm, b = 240 mm
Kalzip® vapour control layer Structural deck Rafter
Detail 506
05.05.04
Construction detail - purlin roof Kalzip DuoPlus® 511 Duo-pitch ridge
Ridge turn up Spacer profile Fixing of ridge flashing: max. distance 400 mm, not into standing seam
Ridge flashing Fixed point clip Thermal barrier Filler block
Insulation rigid
≥ 100
≥ 70
Ridge closure Kalzip®
Timber bearer
Structural deck
Kalzip vapour control layer
Top-hat sub-purlin
Insulation - rigid
Purlin
Kalzip rock wool insulation
Rafter
®
®
Ridge flashing furring Ridge flashing
Alternative with timber ridge bearer
01.02.04 scale 1:5
Alternative with top-hat sub-purlin
Detail 511
Construction detail - rafter roof Kalzip DuoPlus® 521 Dripping eaves
DuoPlus Clip
Gutter
Kalzip®
Filler block
Insulation - rigid
Drip angle
Timber spacer Closure flashing Kalzip® rock wool insulation
Gutter brackets Treated timber
Thermal isolation strip
Closure profile to structural liner tray Kalzip® vapour control layer
Internal closure flashing
Structural liner tray
Structural layer
Sealing strip 2x
Insulation
Rafter Kalbau® SN 18/76
Detail 521
01.02.04 scale 1:5
Construction detail - rafter roof Kalzip DuoPlus® 531 Verge
Angel Kalzip® transition sheet Closure profile to structural liner tray
Kalzip® DuoPlus Clip DuoPlus track 45° Kalzip® rock wool insulation
Retainer flashing
Insulation - rigid
Sealing strip
Structural liner tray Insulation
Kalzip® vapour control layer Structural deck
Kalbau® SN 18/76 Sealing strip
Thermal isolation strip
01.02.04 scale 1:5
Detail 531
Notes
www.kalzip.com Austria Corus Bausysteme Bruckner Büro Center Honauerstraße 2 A-4020 Linz · Austria T +43 - 7 32 78 61 14 F +43 - 7 32 78 61 15
[email protected] Belgium Corus Building Systems NV A. Stocletlaan 87 B-2570 Duffel · Belgium T +32 - 15 30 29 22 F +32 - 15 30 29 20
[email protected] Cyprus Phanos N. Epiphaniou Ltd. 21 Markou Drakou Avenue Pallouriotissa P.O. Box 9078 CY-1621 Nicosia Cyprus T +35 - 722 79 35 20 F +35 - 722 43 15 34
[email protected] Czech Republic and Slovakia Engineering Office Eva Sanovcová Cejl 20 CZ-60200 Brno Czech Republic T +42 - 05 45 11 74 40 F +42 - 05 45 11 74 55
[email protected] Denmark Corus ByggeSystemer A/S Kaarsbergsvej 2 Box 136 DK-8400 Ebeltoft Denmark T +45 - 8953 2000 F +45 - 8953 2001
[email protected] France Corus Building Systems SAS 8, Avenue Desclers · B.P. 20 F-77515 Faremoutiers France T +33 - 1 64 65 30 56 F +33 - 1 64 03 98 55
[email protected] Greece Phanos N. Epiphaniou Ltd. 82 Grammou Str. GR-18345 Moschato Greece T +30 - 21 09 40 59 41 F +30 - 21 09 41 24 65
[email protected]
Italy Corus S.C. Milano SpA Via Treves 21/23 I-20090 Trezzano sul Naviglio (Milano) Italy Ufficio Milano Dott. Ing. Giacomo Magnifico Via Merano 13 I-20060 Gessate (MI) · Italy T +39 - 02 95 38 13 07 F +39 - 02 95 38 03 97
[email protected] Ufficio Verona Dott. Ing. Nicola Finato Vicolo Crocioni n.4 I-37122 Verona · Italy T +39 - 045 800 35 49 F +39 - 045 59 33 77
[email protected] The Netherlands HAFKON BV Postbus 46 NL-3140 AA Maassluis The Netherlands T +31 - 105 91 53 00 F +31 - 105 91 51 25
[email protected] Norway Corus Bygg Systemer AS Røraskogen 2 N-3739 Skien · Norway T +47 - 3591 5200 F +47 - 3591 5201
[email protected]
English
Switzerland Büro Dach & Wand Jürg Senteler P.O. Box 247 CH-7302 Landquart · Switzerland T +41 (0) 81 3 22 38 38 F +41 (0) 81 3 22 38 39
[email protected] Turkey Tür Group Architectural Materials Mahmut Sk. No: 8 TR-81200 Kosuyolo-Istanbul · Turkey T +90 - 216 327 4720 F +90 - 216 327 4724
[email protected] United Kingdom and Ireland Corus Building Systems Haydock Lane, Haydock GB-St. Helens · Merseyside WA11 9TY United Kingdom T +44 - 19 42 29 55 00 F +44 - 19 42 27 21 36
[email protected] Overseas: Near East
Poland A-B Space Lukasz Lomozik Ul. Stawowa 31 B PL-43-250 Pawlowice SI. · Poland T +48 - 32 47 25 110 F +48 - 32 47 57 010
[email protected] Portugal Corus Sistemas Constructivos Lda. Av. dos Combatentes 76 Abrunheira P-2710-034 Sintra · Portugal T +35 - 12 19 15 88 00 F +35 - 12 19 15 88 09
[email protected] Spain Corus Sistemas Constructivos S.L.U. Calle Guatemala, 1 Bajos 3 y 4 E-28016 Madrid · Spain T +34 - 9 13 43 03 43 F +34 - 9 13 59 94 73
[email protected]
Corus Bausysteme GmbH August-Horch-Str. 20-22 · D-56070 Koblenz P.O. Box 10 03 16 · D-56033 Koblenz T +49 (0) 2 61 - 98 34-0 F +49 (0) 2 61 - 98 34-100
[email protected]
Sweden Corus ByggSystem AB Sliparegatan 5 · Box 4003 S-300 04 Halmstad · Sweden T +46 - 3510 0110 F +46 - 3515 9200
[email protected]
Lebanon Naggiar Agencies SCS P.O. Box 175415 Beirut Negib Hobeika Street LB-Saifi-Beirut 20296406 Lebanon T +961 - 1 56 26 52 F +961 - 1 44 83 91
[email protected] www.naggiar.com.lb
Overseas: Far East China/Guangzhou Corus Building Systems Suite 1208, West Tower Yang Cheng International Commercial Centre Tian He Ti Yu Dong Road Guangzhou, PR China 510620 T +86 - 20 38 87 01 90/91 F +86 - 20 38 87 02 65
[email protected] www.kalzip.com.cn China/Beijing Corus Building Systems Suite 610, Jing Guang Centre Office Building, Hujialou Chao Yang District Beijing, PR China 100020 T +86 - 10 65 97 42 25/41 45 F +86 - 10 65 97 42 26
[email protected] China/Shanghai Corus Building Systems Suite 3002, Lt Chengdu North Road Shanghai, PR China 200003 T +86 - 21 63 52 61 22 F +86 - 21 63 60 33 99
[email protected] Hong Kong Corus Building Systems Room 1903, Asia Orient Tower 33 Lockhart Road, Wan Chai Hong Kong T +852 - 28 87 53 41 F +852 - 22 34 67 39
[email protected] Singapore Corus Building Systems Pte Ltd 41 Gul Circle Singapore 629576 T +65 - 67 68 90 81 F +65 - 68 98 93 74
[email protected] www.corus.com.sg Overseas: Australia
Overseas: Middle East Dubai Corus Building Systems P.O. Box 18294 Jebel Ali UAE-Dubai · United Arab Emirates T +971 - 48 87 32 32 F +971 - 48 87 39 77
[email protected]
Australia Corus Building Systems 80/82 Hallam South Road Hallam Victoria · Australia T +61 - 387 95 78 33 F +61 - 387 95 78 44
Kuwait Ali Alghanim & Sons Trading & Contracting Group Co. W.L.L. · P.O. Box 21540 KT-Safat 13076 · Kuwait T +965 - 4 84 22 23 F +965 - 4 84 18 12 The product information and technical details contained in this brochure are accurate, according to our research and technical programme, at the point of going to press. They do not refer to any specific application and cannot give rise to claims for compensation. We reserve the right to make any changes to the construction or product range which seem technically appropriate, in view of our high standards for product advancement and development. Copyright 2004
Corus Bausysteme GmbH · Part of Corus Group plc