A Wholistic Approach to HRSG Inspections Charles Turner, P.Eng. Charles G. Turner & Associates Ltd. Consulting Engineers Presented at the 2014 Canadian HRSG Forum October 21, 2014
Charles G. Turner & Associates Ltd.
Charles G. Turner and Associates Ltd. (CGTA) Consulting
Engineers specializing in Power
& Utilities Founded
Located
in 1973
in Toronto, Ontario, Canada
Charles G. Turner & Associates Ltd.
Charles G. Turner and Associates Ltd. (CGTA) Consulting
Engineers specializing in Power
& Utilities Founded
Located
in 1973
in Toronto, Ontario, Canada
Charles G. Turner & Associates Ltd.
CGTA Areas of Expertise Simple
Cycle and Combined Cycle Power Plants
Thermal Power Stations (Coal, Gas & Oil Fired)
Cogeneration
(Steam Turbines, Gas Turbines & Reciprocating Engines)
Central
Heating Plants (Steam Boilers, Thermal Fluid Heaters & Vaporizers, Glycol & Hot Water, Plant Auxiliaries, buried steam & HW distribution piping)
Central
Cooling Plants (Chilled Water, Refrigerant, Steam Absorption & Ammonia, buried chilled water distribution piping) Charles G. Turner & Associates Ltd.
CGTA Areas of Expertise Continued Burners
& Combustion (Natural Gas, Fuel Oil, Liquid and Gaseous Process Fuels, Biomass)
Water
Treatment Systems
Compressed
Gas Plants (Air, Digester Gas, Landfill Gas and Carbon Dioxide)
Industrial
Plant Processes
Industrial
HVAC
Cooling
Tower Systems
Instrumentation Electrical
& Controls (PLC & DCS)
Generation (High and Low Voltage) Charles G. Turner & Associates Ltd.
Putting “Wholistic” into HRSG Inspections
Wholistic refers to the approach and execution of the HRSG inspection, where the HRSG is inspected from an asset integrity and management approach.
The approach integrates the HRSG inspection and boundary limits into the Company’s long term maintenance plan that includes; – Integrity Plans – SAMP’s – Long Term Maintenance Plan Charles G. Turner & Associates Ltd.
Aligning Inspection Deliverables within the Asset Management Plans •
What is a Corporate Asset Management Plan?
Defines the organizational goals and objectives of the plant components.
Defines performance targets.
Provides future demand forecasts.
Specifies regulatory requirements.
Identifies site specific maintenance intervals, capital and operating improvement projects.
Records equipment condition.
Provides a summary location for the performance history and operating strategy to maintain performance requirements. Charles G. Turner & Associates Ltd.
HRSG Integrity Plans •
HRSG Integrity Plans are developed to support the Asset Management Plans:
Defines the life cycle wholistic view of the specific equipment.
Incorporates Operations and Maintenance strategies.
Develops Risk Assessment including analysis and consequences.
Defines Provincial and State compliance requirements.
Assurance of Insurance compliance requirements.
Provides a basis for the lessons learned.
Charles G. Turner & Associates Ltd.
Critical Pre-Inspection Key Parameters
HRSG Superstructure Design
Bottom supported components
Top hung from casing superstructure
Waste Heat Source:
Gas Turbine - Size/Make/Model
Duct Firing – Location and rating
Operating Parameters
Number of Pressure Levels
Pressure/Temperature
Operating Hours
Number of Cold Iron Starts, Cold/Warm/Hot Starts, Forced Cooling Events, and EOH’s. Charles G. Turner & Associates Ltd.
Critical Pre-Inspection Key Parameters Continued
High Temperature Materials
P91/T23
Hardened Low Temperature Regions for FAC
In-Cycle water treatment program
HP & IP Phosphate / LP – SALP or FFLP?
Once Through requirements.
Cascading Blowdown.
Charles G. Turner & Associates Ltd.
Typical F Technology Triple Pressure HRSG
Charles G. Turner & Associates Ltd.
Once Through Steam Generator
Charles G. Turner & Associates Ltd.
Enhanced Oil Recovery Once Through Wet Steam Generator
Charles G. Turner & Associates Ltd.
External Casing Inspection
Charles G. Turner & Associates Ltd.
Casing Expansion Joint Limited Flexibility
Charles G. Turner & Associates Ltd.
Casing Hot Spots
Charles G. Turner & Associates Ltd.
External Casing Liquid Refractory Injection Locations
Charles G. Turner & Associates Ltd.
Thermography Analysis Transition Duct Liner Issue
Casing Hotspot
Charles G. Turner & Associates Ltd.
Thermography Analysis Sidewall Bellows Failure
Door Seal Leak
Charles G. Turner & Associates Ltd.
External Piping Supports
Charles G. Turner & Associates Ltd.
HEP BEP Supports
Charles G. Turner & Associates Ltd.
HEP BEP Supports
Charles G. Turner & Associates Ltd.
HRSG Superstructure Supports
Charles G. Turner & Associates Ltd.
Duct Burner Blowers
Charles G. Turner & Associates Ltd.
Duct Burner Manifolds
Charles G. Turner & Associates Ltd.
Preheater Recirculation Pump
Charles G. Turner & Associates Ltd.
Pump Inlet Expansion Joint
Charles G. Turner & Associates Ltd.
Preheater Expansion Joint Misalignment
Charles G. Turner & Associates Ltd.
Preheater Expansion Joint Failure
Charles G. Turner & Associates Ltd.
Lower Vestibules
Charles G. Turner & Associates Ltd.
Chemical Clean Connections
Charles G. Turner & Associates Ltd.
Gasket Leaks
Charles G. Turner & Associates Ltd.
Small Bore Drain Line Pinhole Leaks
Charles G. Turner & Associates Ltd.
OTSG Side Vestibules
Charles G. Turner & Associates Ltd.
OTSG Sidewall Bundle Restraint
Charles G. Turner & Associates Ltd.
Lower Vestibule and Outlet Header
Charles G. Turner & Associates Ltd.
Swaged Fitting Tube Plugs
Charles G. Turner & Associates Ltd.
EOR OTSG Vestibule
Charles G. Turner & Associates Ltd.
EOR OTSG Return Bend Inspection
Charles G. Turner & Associates Ltd.
Drain Lines Inspection
Charles G. Turner & Associates Ltd.
Corrosion Under Insulation
Charles G. Turner & Associates Ltd.
Internally Insulated Gas Tight Expansion Joint
Charles G. Turner & Associates Ltd.
Removed Drain Line
Charles G. Turner & Associates Ltd.
Corroded Drain Line
Charles G. Turner & Associates Ltd.
Distorted Vestibule Upper Tubesheet Limit Guide
Charles G. Turner & Associates Ltd.
Tubesheet to Fin Tube Lockup
Charles G. Turner & Associates Ltd.
Upper Vestibule Vent Line Distortion
Charles G. Turner & Associates Ltd.
Tube Support Module Splay
Charles G. Turner & Associates Ltd.
HRSG Inlet Transition Section
Charles G. Turner & Associates Ltd.
OTSG Steam Outlet Header
Charles G. Turner & Associates Ltd.
Tubesheet Distortion
Charles G. Turner & Associates Ltd.
Tubesheet Witness Marks
Charles G. Turner & Associates Ltd.
Fin Tube to Tubesheet Ratcheting Effect
Charles G. Turner & Associates Ltd.
Tube Collar Installation
Charles G. Turner & Associates Ltd.
Tube Collar Migration
Charles G. Turner & Associates Ltd.
Tube to Tubesheet Ratcheting and Collar Movement
Charles G. Turner & Associates Ltd.
OTSG End Gas Seal Plates
Charles G. Turner & Associates Ltd.
OTSG Tube Return Bends
Charles G. Turner & Associates Ltd.
Return Bend Indentation
Charles G. Turner & Associates Ltd.
OTSG Return Bend Indentation
Charles G. Turner & Associates Ltd.
Exhaust Gas Distributor
Charles G. Turner & Associates Ltd.
Exhaust Gas Perforated Plate
Charles G. Turner & Associates Ltd.
Duct Burners
Charles G. Turner & Associates Ltd.
Vertical Duct Burner
Charles G. Turner & Associates Ltd.
Horizontal Configuration Duct Burner
Charles G. Turner & Associates Ltd.
Duct Burner Fixed Igniter End
Charles G. Turner & Associates Ltd.
Bat Wing Bluff Body Configurations
Charles G. Turner & Associates Ltd.
Duct Burner Floating Element End
Charles G. Turner & Associates Ltd.
Duct Burner Element Wall Liner Distortion
Charles G. Turner & Associates Ltd.
Duct Burner Pinning
Charles G. Turner & Associates Ltd.
Duct Burner Cavity Liner Distortion
Charles G. Turner & Associates Ltd.
Duct Burner Cavity Wall Liner Distortion
Charles G. Turner & Associates Ltd.
Duct Burner Cavity Liner Replacement
Charles G. Turner & Associates Ltd.
Inlet Duct Insulation Block
Charles G. Turner & Associates Ltd.
Superheater & Reheater Modules
Charles G. Turner & Associates Ltd.
HRSG Bottom Supported Superheater
Charles G. Turner & Associates Ltd.
Sliding Floor Seal Distortion
Charles G. Turner & Associates Ltd.
Floor Seal Plate Failure
Charles G. Turner & Associates Ltd.
Tube Distortion and Migration
Charles G. Turner & Associates Ltd.
Plug Weld Failures
Charles G. Turner & Associates Ltd.
Scallop Bar Failure & Distortion
Charles G. Turner & Associates Ltd.
Scallop Bar Tube Impingement
Charles G. Turner & Associates Ltd.
Robust Scallop Bar Design
Charles G. Turner & Associates Ltd.
OTSG HP Superheater Tubes
Charles G. Turner & Associates Ltd.
Swollen HP SH Tube
Charles G. Turner & Associates Ltd.
OTSG Tube Rupture
Charles G. Turner & Associates Ltd.
OTSG Circuit Plugging
Charles G. Turner & Associates Ltd.
OTSG SH Ruptured Tube
Charles G. Turner & Associates Ltd.
Freeze Damage
Charles G. Turner & Associates Ltd.
Superheater & Reheater Upper Vestibule Floor Seal Plates
Charles G. Turner & Associates Ltd.
Upper Header Supports
Charles G. Turner & Associates Ltd.
Top Hung Module Saddle Supports
Charles G. Turner & Associates Ltd.
Support Saddle Crack
Charles G. Turner & Associates Ltd.
Tube to Header Inspections
Charles G. Turner & Associates Ltd.
Superheater Toe Welds
Charles G. Turner & Associates Ltd.
Lower HP SH & RH Links
Charles G. Turner & Associates Ltd.
Lower SH Drains & Penetrations
Charles G. Turner & Associates Ltd.
Evaporator & Feedwater Modules
Charles G. Turner & Associates Ltd.
Exfoliated Fin Deposits
Charles G. Turner & Associates Ltd.
Feedwater Heater Vents & Supports
Charles G. Turner & Associates Ltd.
Top Support Systems
Charles G. Turner & Associates Ltd.
Evaporator Support Fixtures
Charles G. Turner & Associates Ltd.
Exhaust Duct and Stack
Charles G. Turner & Associates Ltd.
Heavy Exfoliation and Sulphur Deposition
Charles G. Turner & Associates Ltd.
Preheater Tube UT Wall Thickness Monitoring
Charles G. Turner & Associates Ltd.
Exhaust Transition Expansion Joint
Charles G. Turner & Associates Ltd.
Exhaust Duct/Stack Inlet Expansion Joint
Charles G. Turner & Associates Ltd.
Sulphur Deposits
Charles G. Turner & Associates Ltd.
Sulphur On Stack Floor
Charles G. Turner & Associates Ltd.
Rectangular Duct Damper Blades
Charles G. Turner & Associates Ltd.
Typical Circular Stack Butterfly Damper
Charles G. Turner & Associates Ltd.
Closed Butterfly Dampers
Charles G. Turner & Associates Ltd.
Stack Silencers
Charles G. Turner & Associates Ltd.
Drum Inspections
Charles G. Turner & Associates Ltd.
Primary Separators, Secondary Mesh Demisters and Chevrons
Charles G. Turner & Associates Ltd.
Drum Wall Wash Effect
Charles G. Turner & Associates Ltd.
HP Drum Primary Separators and Demister/Chevron Assemblies
Charles G. Turner & Associates Ltd.
Underside of HP Primary Separator
Charles G. Turner & Associates Ltd.
HP Drum Floor Deposits
Charles G. Turner & Associates Ltd.
Chevron Separator Failure
Charles G. Turner & Associates Ltd.
Demister Pad Blow Out
Charles G. Turner & Associates Ltd.
Demister Pad/Chevron Assembly at Saturated Steam Lead
Charles G. Turner & Associates Ltd.
Steam Water Level Line
Charles G. Turner & Associates Ltd.
HP Downcomer Passivation
Charles G. Turner & Associates Ltd.
IP Drum
Charles G. Turner & Associates Ltd.
IP Demister Pads
Charles G. Turner & Associates Ltd.
LP Drum
Charles G. Turner & Associates Ltd.
LP Drum Water Line
Charles G. Turner & Associates Ltd.
LP Feedwater and Evaporator Riser Distributors
Charles G. Turner & Associates Ltd.
LP Drum Deposits
Charles G. Turner & Associates Ltd.
LP Demister Pads
Charles G. Turner & Associates Ltd.
Door Castellation Seals
Charles G. Turner & Associates Ltd.
Don’t Forget the Blowdown Tank
Charles G. Turner & Associates Ltd.
And Remember the Interstage Attemperators
Charles G. Turner & Associates Ltd.
Tig Weld Cracks
Charles G. Turner & Associates Ltd.
And Borescope Liner Upstream & Downstream
Charles G. Turner & Associates Ltd.
Now On To Pigging
Charles G. Turner & Associates Ltd.
Cleaning Pig & Before/After Foam Dewatering Pigs
Charles G. Turner & Associates Ltd.
Feedwater Inlet & Steam Outlet Borescopes
Charles G. Turner & Associates Ltd.
Pig Launcher
Charles G. Turner & Associates Ltd.
Pig Launchers/Receivers
Charles G. Turner & Associates Ltd.
Borescope Inspection
Charles G. Turner & Associates Ltd.
Pigged Steam Lines
Charles G. Turner & Associates Ltd.
Pigged Gasket Results
Charles G. Turner & Associates Ltd.
Incorporating the Inspection Results into the LONG TERM MAINTENANCE PLAN
The Long Term Maintenance Plan (LTMP) will define the scope, frequency and estimated cost of equipment maintenance required to attain expected plant availability.
The LTMP will be built based on the outputs of the equipment Integrity Plans and the System Asset Management Plans (SAMP). Integrity Plans Objective: Develop equipment specific plans defining maintenance intervals, related projects and applicable operating procedures.
SAMP’s Objective: Develop specific plans utilizing operating assumptions and performance history
Charles G. Turner & Associates Ltd.
LTMP Objective: Develop wholistic plant view on scope, frequency and cost of outages over 5 and 20 year horizons
LTMP & Business Plan LTMP Linkage with the Annual Business Plan •
•
The LTMP will include the following;
Discussion on Integrity Plans and SAMP content as it relates to the long term maintenance requirements.
Short term view showing major outage work scopes, durations and cost estimates.
Long term view showing major outage work scopes, durations and cost estimates.
With the combination of Integrity Plans and SAMP’s in the LTMP, which should be reviewed and updated on an annual basis, the annual Business Plan will contain an accurate maintenance scope, duration and cost estimates for the coming year.
Charles G. Turner & Associates Ltd.
Incorporating the Inspection Findings into a Risk Registry
The Risk Registry is a tool used to document risks known to Management and associated mitigation activities. As a group the management team distributes risks appropriately to team members, who become the “risk manager”. The Risk Manager is responsible for documenting current mitigation activities or developing strategies for further mitigation when appropriate.
Charles G. Turner & Associates Ltd.
Calculate Risk Value •
A Risk Value is calculated using the probability, frequency and impact values.
Charles G. Turner & Associates Ltd.
A Wholistic Approach to HRSG Inspections Concluding
remarks:
– Know what you are up against. – Begin the inspection with the end in mind. – Understand the deliverables of the inspection. – Hope for the best, prepare for the worst. Charles G. Turner & Associates Ltd.