WCDMA RAN, Rel. RU40, Operating Documentation, Issue 04WCDMA RAN, Rel. RU40, Operating Documentation, Issue 04
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900) DN99580892 Issue 10B Approval Date 2013-06-14
Confidential
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Solutions and Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Solutions and Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Solutions and Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation. The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given "as is" and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Solutions and Networks and the customer. However, Nokia Solutions and Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Solutions and Networks will, if deemed necessary by Nokia Solutions and Networks, explain issues which may not be covered by the document. Nokia Solutions and Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL Nokia Solutions and Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT. This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws. NSN is a trademark of Nokia Solutions and Networks. Nokia is a registered trademark of Nokia Corporation. Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only. Copyright © 2013 Nokia Solutions and Networks. All rights reserved.
f
Important Notice on Product Safety This product may present safety risks due to laser, electricity, heat, and other sources of danger. Only trained and qualified personnel may install, operate, maintain or otherwise handle this product and only after having carefully read the safety information applicable to this product. The safety information is provided in the Safety Information section in the “Legal, Safety and Environmental Information” part of this document or documentation set.
Nokia Solutions and Networks is continually striving to reduce the adverse environmental effects of its products and services. We would like to encourage you as our customers and users to join us in working towards a cleaner, safer environment. Please recycle product packaging and follow the recommendations for power use and proper disposal of our products and their components. If you should have questions regarding our Environmental Policy or any of the environmental services we offer, please contact us at Nokia Solutions and Networks for any additional information.
2
Id:0900d805809d5bdf Confidential
DN99580892 Issue 10B
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
Table of Contents This document has 292 pages. Summary of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
DN99580892
1
List of Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2
7401 EXTERNAL AL 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3
7402 EXTERNAL AL 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
4
7403 EXTERNAL AL 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5
7404 EXTERNAL AL 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
6
7405 EXTERNAL AL 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
7
7406 EXTERNAL AL 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
8
7407 EXTERNAL AL 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
9
7408 EXTERNAL AL 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
10
7409 EXTERNAL AL 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
11
7410 EXTERNAL AL 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
12
7411 EXTERNAL AL 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
13
7412 EXTERNAL AL 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
14
7413 EXTERNAL AL 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
15
7414 EXTERNAL AL 14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
16
7415 EXTERNAL AL 15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
17
7416 EXTERNAL AL 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
18
7417 EXTERNAL AL 17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
19
7418 EXTERNAL AL 18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
20
7419 EXTERNAL AL 19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
21
7420 EXTERNAL AL 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
22
7421 EXTERNAL AL 21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
23
7422 EXTERNAL AL 22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
24
7423 EXTERNAL AL 23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
25
7424 EXTERNAL AL 24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
26
7425 EXTERNAL AL 25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
27
7426 EXTERNAL AL 26 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
28
7650 BASE STATION FAULTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
29
7651 BASE STATION OPERATION DEGRADED . . . . . . . . . . . . . . . . 70
30
7652 BASE STATION NOTIFICATION . . . . . . . . . . . . . . . . . . . . . . . . 119
Id:0900d805809d5bdf Confidential
3
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
4
31
7653 CELL FAULTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
32
7654 CELL OPERATION DEGRADED . . . . . . . . . . . . . . . . . . . . . . . . 174
33
7655 CELL NOTIFICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202
34
7660 BASE STATION LICENCE EXPIRED . . . . . . . . . . . . . . . . . . . . . 211
35
7661 BASE STATION LICENCE NOTIFICATION . . . . . . . . . . . . . . . . 213
36
7665 BASE STATION TRANSMISSION ALARM . . . . . . . . . . . . . . . . . 216
37
7740 BEATING WCDMA BTS ALARM. . . . . . . . . . . . . . . . . . . . . . . . . 238
38
7750 FAILURE IN WCDMA WBTS O&M CONNECTION . . . . . . . . . . 239
39
7761 RNW O&M SCENARIO FAILURE . . . . . . . . . . . . . . . . . . . . . . . . 243
40
7762 RNW DATABASE OPERATION FAILURE . . . . . . . . . . . . . . . . . 249
41
7771 WCDMA CELL OUT OF USE . . . . . . . . . . . . . . . . . . . . . . . . . . . 252
42
7772 HSDPA CONFIGURATION FAILED . . . . . . . . . . . . . . . . . . . . . . 255
43
7773 INSECURE O&M CONNECTION . . . . . . . . . . . . . . . . . . . . . . . . 260
44
7775 INCONSISTENCY IN WCEL CONFIGURATION PARAMETERS . . 261
45
7776 HSDPA FAILURE IN WCEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264
46
7778 WCDMA BTS DEDICATED MEASUREMENT FAILURE . . . . . . 266
47
7779 RECOVERY ACTIONS ONGOING . . . . . . . . . . . . . . . . . . . . . . . 268
48
7780 HSUPA FAILURE IN WCEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270
49
7781 NETWORK ELEMENT CONFIGURATION ERROR . . . . . . . . . . 272
50
7782 HSUPA CONFIGURATION FAILED . . . . . . . . . . . . . . . . . . . . . . 274
51
7783 IP BASED D-NBAP LINK FAILURE. . . . . . . . . . . . . . . . . . . . . . . 279
52
7784 RECOVERY ACTION FAILURE . . . . . . . . . . . . . . . . . . . . . . . . . 280
53
7786 WCDMA BASE STATION OUT OF USE. . . . . . . . . . . . . . . . . . . 283
54
7794 ALARM STATUS REQUEST HAS TIMED OUT . . . . . . . . . . . . . 286
55
7795 INCONSISTENCY IN HIGH PEAK RATE HSPA CONFIG . . . . . 287
56
7796 HIGH SPEED COMMON CHANNEL PROBLEM . . . . . . . . . . . . 290
Id:0900d805809d5bdf Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
Summary of changes
Summary of changes Changes between document issues are cumulative. Therefore, the latest document issue contains all changes made to previous issues. Changes made between issues 10A and 10B
Modified alarm 7775 Changes made between issues 10 and 10A
Modified alarms 7651
7653
Changes made between issues 09F and 10
Modified alarms
DN99580892
7650
7660
7772
7782
7651
7661
7773
7783
7652
7665
7775
7784
7653
7761
7778
7786
7654
7762
7779
7795
7655
7771
7781
7796
Id:0900d805809d5c0d Confidential
5
List of Alarms
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
1 List of Alarms
6
7401
EXTERNAL AL 1
7402
EXTERNAL AL 2
7403
EXTERNAL AL 3
7404
EXTERNAL AL 4
7405
EXTERNAL AL 5
7406
EXTERNAL AL 6
7407
EXTERNAL AL 7
7408
EXTERNAL AL 8
7409
EXTERNAL AL 9
7410
EXTERNAL AL 10
7411
EXTERNAL AL 11
7412
EXTERNAL AL 12
7413
EXTERNAL AL 13
7414
EXTERNAL AL 14
7415
EXTERNAL AL 15
7416
EXTERNAL AL 16
7417
EXTERNAL AL 17
7418
EXTERNAL AL 18
7419
EXTERNAL AL 19
7420
EXTERNAL AL 20
7421
EXTERNAL AL 21
7422
EXTERNAL AL 22
7423
EXTERNAL AL 23
7424
EXTERNAL AL 24
7425
EXTERNAL AL 25
7426
EXTERNAL AL 26
7650
BASE STATION FAULTY
7651
BASE STATION OPERATION DEGRADED
7652
BASE STATION NOTIFICATION
7653
CELL FAULTY
7654
CELL OPERATION DEGRADED
7655
CELL NOTIFICATION
7660
BASE STATION LICENCE EXPIRED
7661
BASE STATION LICENCE NOTIFICATION
7665
BASE STATION TRANSMISSION ALARM
7740
BEATING WCDMA BTS ALARM
7750
FAILURE IN WCDMA WBTS O&M CONNECTION
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
List of Alarms
7761
RNW O&M SCENARIO FAILURE
7762
RNW DATABASE OPERATION FAILURE
7771
WCDMA CELL OUT OF USE
7772
HSDPA CONFIGURATION FAILED
7773
INSECURE O&M CONNECTION
7775
INCONSISTENCY IN WCEL CONFIGURATION PARAMETERS
7776
HSDPA FAILURE IN WCEL
7778
WCDMA BTS DEDICATED MEASUREMENT FAILURE
7779
RECOVERY ACTIONS ONGOING
7780
HSUPA FAILURE IN WCEL
7781
NETWORK ELEMENT CONFIGURATION ERROR
7782
HSUPA CONFIGURATION FAILED
7783
IP BASED D-NBAP LINK FAILURE
7784
RECOVERY ACTION FAILURE
7786
WCDMA BASE STATION OUT OF USE
7794
ALARM STATUS REQUEST HAS TIMED OUT
7795
INCONSISTENCY IN HIGH PEAK RATE HSPA CONFIG
7796
HIGH SPEED COMMON CHANNEL PROBLEM
Alarm parameters The following parameter settings are the default settings. The operator can modify them with MML/SCLI command. The following listing also contains alarm event types. Please note that this information is not part of the alarm parameter listing and it is not possible to change those values using MML/SCLI commands. The information here is for documentation purposes only. NR
TEXT CLS OUT SDC SDD CDL LVT -------------------------------------------------------------------------------7401
7402
7403
7404
EXTERNAL AL 1 00:10 00:10 EVENT TYPE: ENVIRONMENTAL
-
EXTERNAL AL 2 00:10 00:10 EVENT TYPE: ENVIRONMENTAL
-
EXTERNAL AL 3 00:10 00:10 EVENT TYPE: ENVIRONMENTAL
-
EXTERNAL AL 4 00:10 00:10 EVENT TYPE: ENVIRONMENTAL
-
DN99580892
Id:0900d805809d5c0d Confidential
*
NONE
*
NONE
*
NONE
*
NONE
7
List of Alarms
7405
7406
7407
7408
7409
7410
7411
7412
7413
7414
7415
7416
7417
8
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
EXTERNAL AL 5 00:10 00:10 EVENT TYPE: ENVIRONMENTAL
-
EXTERNAL AL 6 00:10 00:10 EVENT TYPE: ENVIRONMENTAL
-
EXTERNAL AL 7 00:10 00:10 EVENT TYPE: ENVIRONMENTAL
-
EXTERNAL AL 8 00:10 00:10 EVENT TYPE: ENVIRONMENTAL
-
EXTERNAL AL 9 00:10 00:10 EVENT TYPE: ENVIRONMENTAL
-
EXTERNAL AL 10 00:10 00:10 EVENT TYPE: ENVIRONMENTAL
-
EXTERNAL AL 11 00:10 00:10 EVENT TYPE: ENVIRONMENTAL
-
EXTERNAL AL 12 00:10 00:10 EVENT TYPE: ENVIRONMENTAL
-
EXTERNAL AL 13 00:10 00:10 EVENT TYPE: ENVIRONMENTAL
-
EXTERNAL AL 14 00:10 00:10 EVENT TYPE: ENVIRONMENTAL
-
EXTERNAL AL 15 00:10 00:10 EVENT TYPE: ENVIRONMENTAL
-
EXTERNAL AL 16 00:10 00:10 EVENT TYPE: ENVIRONMENTAL
-
EXTERNAL AL 17 00:10 00:10 EVENT TYPE: ENVIRONMENTAL
-
Id:0900d805809d5c0d Confidential
*
NONE
*
NONE
*
NONE
*
NONE
*
NONE
*
NONE
*
NONE
*
NONE
*
NONE
*
NONE
*
NONE
*
NONE
*
NONE
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7418
7419
7420
7421
7422
7423
7424
7425
7426
7650
EXTERNAL AL 18 00:10 00:10 EVENT TYPE: ENVIRONMENTAL
-
EXTERNAL AL 19 00:10 00:10 EVENT TYPE: ENVIRONMENTAL
-
EXTERNAL AL 20 00:10 00:10 EVENT TYPE: ENVIRONMENTAL
-
EXTERNAL AL 21 00:10 00:10 EVENT TYPE: ENVIRONMENTAL
-
EXTERNAL AL 22 00:10 00:10 EVENT TYPE: ENVIRONMENTAL
-
EXTERNAL AL 23 00:10 00:10 EVENT TYPE: ENVIRONMENTAL
-
EXTERNAL AL 24 00:10 00:10 EVENT TYPE: ENVIRONMENTAL
-
EXTERNAL AL 25 00:10 00:10 EVENT TYPE: ENVIRONMENTAL
-
EXTERNAL AL 26 00:10 00:10 EVENT TYPE: ENVIRONMENTAL
-
BASE STATION FAULTY 00:10 00:10 EVENT TYPE: EQUIPMENT
List of Alarms
*
NONE
*
NONE
*
NONE
*
NONE
*
NONE
*
NONE
*
NONE
*
NONE
*
NONE
***
0
-
7651
BASE STATION OPERATION DEGRADED 00:10 00:10 EVENT TYPE: EQUIPMENT
**
5
7652
BASE STATION NOTIFICATION 00:10 00:10 EVENT TYPE: EQUIPMENT
*
NONE
***
0
7653
CELL FAULTY 00:10 -
DN99580892
00:10
-
-
Id:0900d805809d5c0d Confidential
9
List of Alarms
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
EVENT TYPE: EQUIPMENT 7654
7655
CELL OPERATION DEGRADED 00:10 00:10 EVENT TYPE: EQUIPMENT CELL NOTIFICATION 00:10 00:10 EVENT TYPE: EQUIPMENT
**
5
*
NONE
-
-
7660
BASE STATION LICENCE EXPIRED 00:10 00:10 EVENT TYPE: EQUIPMENT
***
0
7661
BASE STATION LICENCE NOTIFICATION 00:10 00:10 EVENT TYPE: EQUIPMENT
*
NONE
7665
BASE STATION TRANSMISSION ALARM 00:10 00:10 EVENT TYPE: EQUIPMENT
*
NONE
7740
BEATING WCDMA BTS ALARM 00:00 00:00 EVENT TYPE: PROCESSING ERROR
**
5
7750
FAILURE IN WCDMA WBTS O&M CONNECTION 00:10 00:10 EVENT TYPE: COMMUNICATIONS
*
NONE
7761
RNW O&M SCENARIO FAILURE 00:40 00:00 EVENT TYPE: QUALITY OF SERVICE
**
5
7762
RNW DATABASE OPERATION FAILURE 00:05 00:00 EVENT TYPE: PROCESSING ERROR
**
5
7771
WCDMA CELL OUT OF USE 02:00 00:20 EVENT TYPE: QUALITY OF SERVICE
**
5
7772
HSDPA CONFIGURATION FAILED 00:05 00:05 EVENT TYPE: QUALITY OF SERVICE
**
5
7773
INSECURE O&M CONNECTION 00:00 00:00 EVENT TYPE: COMMUNICATIONS
**
5
7775
INCONSISTENCY IN WCEL CONFIGURATION PARAMETERS
*
NONE
10
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
List of Alarms
00:00 00:00 EVENT TYPE: PROCESSING ERROR 7776
HSDPA FAILURE IN WCEL 00:05 00:00 EVENT TYPE: QUALITY OF SERVICE
**
5
7778
WCDMA BTS DEDICATED MEASUREMENT FAILURE 00:00 00:00 EVENT TYPE: QUALITY OF SERVICE
**
5
7779
RECOVERY ACTIONS ONGOING 00:00 00:00 EVENT TYPE: QUALITY OF SERVICE
*
NONE
7780
HSUPA FAILURE IN WCEL 00:05 00:00 EVENT TYPE: QUALITY OF SERVICE
**
5
7781
NETWORK ELEMENT CONFIGURATION ERROR 00:00 00:00 EVENT TYPE: PROCESSING ERROR
***
2
7782
HSUPA CONFIGURATION FAILED 00:05 00:05 EVENT TYPE: QUALITY OF SERVICE
**
5
7783
IP BASED D-NBAP LINK FAILURE 00:30 00:30 EVENT TYPE: COMMUNICATIONS
**
5
7784
RECOVERY ACTION FAILURE 00:00 00:00 EVENT TYPE: COMMUNICATIONS
**
5
7786
WCMDA BASE STATION OUT OF USE 00:30 00:15 EVENT TYPE: QUALITY OF SERVICE
**
5
7794
ALARM STATUS REQUEST HAS TIMED OUT 00:00 00:00 EVENT TYPE: COMMUNICATIONS
**
5
7795
INCONSISTENCY IN HIGH PEAK RATE HSPA CONFIG 00:15 00:15 EVENT TYPE: PROCESSING ERROR
*
NONE
7796
HIGH SPEED COMMON CHANNEL PROBLEM 00:05 00:00 EVENT TYPE: QUALITY OF SERVICE
*
NONE
DN99580892
Id:0900d805809d5c0d Confidential
11
List of Alarms
12
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7401 EXTERNAL AL 1
2 7401 EXTERNAL AL 1 Meaning This is an external user-defined alarm. The alarm is defined by the user in an HW database. Supplementary information fields
Instructions The operation depends on what kind of alarm is used as external alarm no. 1. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
DN99580892
Id:0900d805809d5c0d Confidential
13
7402 EXTERNAL AL 2
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
3 7402 EXTERNAL AL 2 Meaning This is an external user-defined alarm. The alarm is defined by the user in a HW database. Supplementary information fields
Instructions The operation depends on what kind of alarm is used as external alarm no. 2. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
14
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7403 EXTERNAL AL 3
4 7403 EXTERNAL AL 3 Meaning This is an external user-defined alarm. The alarm is defined by the user in a HW database. Supplementary information fields
Instructions The operation depends on what kind of alarm is used as external alarm no. 3. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
DN99580892
Id:0900d805809d5c0d Confidential
15
7404 EXTERNAL AL 4
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
5 7404 EXTERNAL AL 4 Meaning This is an external user-defined alarm. The alarm is defined by the user in a HW database. Supplementary information fields
Instructions The operation depends on what kind of alarm is used as external alarm no. 4. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
16
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7405 EXTERNAL AL 5
6 7405 EXTERNAL AL 5 Meaning This is an external user-defined alarm. The alarm is defined by the user in a HW database. Supplementary information fields
Instructions The operation depends on what kind of alarm is used as external alarm no. 5. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
DN99580892
Id:0900d805809d5c0d Confidential
17
7406 EXTERNAL AL 6
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7 7406 EXTERNAL AL 6 Meaning This is an external user-defined alarm. The alarm is defined by the user in a HW database. Supplementary information fields
Instructions The operation depends on what kind of alarm is used as external alarm no. 6. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
18
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7407 EXTERNAL AL 7
8 7407 EXTERNAL AL 7 Meaning This is an external user-defined alarm. The alarm is defined by the user in a HW database. Supplementary information fields
Instructions The operation depends on what kind of alarm is used as external alarm no. 7. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
DN99580892
Id:0900d805809d5c0d Confidential
19
7408 EXTERNAL AL 8
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
9 7408 EXTERNAL AL 8 Meaning This is an external user-defined alarm. The alarm is defined by the user in a HW database. Supplementary information fields
Instructions The operation depends on what kind of alarm is used as external alarm no. 8. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
20
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7409 EXTERNAL AL 9
10 7409 EXTERNAL AL 9 Meaning This is an external user-defined alarm. The alarm is defined by the user in a HW database. Supplementary information fields
Instructions The operation depends on what kind of alarm is used as external alarm no. 9. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
DN99580892
Id:0900d805809d5c0d Confidential
21
7410 EXTERNAL AL 10
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
11 7410 EXTERNAL AL 10 Meaning This is an external user-defined alarm. The alarm is defined by the user in a HW database. Supplementary information fields
Instructions The operation depends on what kind of alarm is used as external alarm no. 10. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
22
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7411 EXTERNAL AL 11
12 7411 EXTERNAL AL 11 Meaning This is an external user-defined alarm. The alarm is defined by the user in a HW database. Supplementary information fields
Instructions The operation depends on what kind of alarm is used as external alarm no. 11. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
DN99580892
Id:0900d805809d5c0d Confidential
23
7412 EXTERNAL AL 12
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
13 7412 EXTERNAL AL 12 Meaning This is an external user-defined alarm. The alarm is defined by the user in a HW database. Supplementary information fields
Instructions The operation depends on what kind of alarm is used as external alarm no. 12. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
24
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7413 EXTERNAL AL 13
14 7413 EXTERNAL AL 13 Meaning This is an external user-defined alarm. The alarm is defined by the user in a HW database. Supplementary information fields
Instructions The operation depends on what kind of alarm is used as external alarm no. 13. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
DN99580892
Id:0900d805809d5c0d Confidential
25
7414 EXTERNAL AL 14
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
15 7414 EXTERNAL AL 14 Meaning This is an external user-defined alarm. The alarm is defined by the user in a HW database. Supplementary information fields
Instructions The operation depends on what kind of alarm is used as external alarm no. 14. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
26
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7415 EXTERNAL AL 15
16 7415 EXTERNAL AL 15 Meaning This is an external user-defined alarm. The alarm is defined by the user in a HW database. Supplementary information fields
Instructions The operation depends on what kind of alarm is used as external alarm no. 15. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
DN99580892
Id:0900d805809d5c0d Confidential
27
7416 EXTERNAL AL 16
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
17 7416 EXTERNAL AL 16 Meaning This is an external user-defined alarm. The alarm is defined by the user in a HW database. Supplementary information fields
Instructions The operation depends on what kind of alarm is used as external alarm no. 16. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
28
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7417 EXTERNAL AL 17
18 7417 EXTERNAL AL 17 Meaning This is an external user-defined alarm. The alarm is defined by the user in a HW database. Supplementary information fields
Instructions The operation depends on what kind of alarm is used as external alarm no. 17. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
DN99580892
Id:0900d805809d5c0d Confidential
29
7418 EXTERNAL AL 18
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
19 7418 EXTERNAL AL 18 Meaning This is an external user-defined alarm. The alarm is defined by the user in a HW database. Supplementary information fields
Instructions The operation depends on what kind of alarm is used as external alarm no. 18. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
30
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7419 EXTERNAL AL 19
20 7419 EXTERNAL AL 19 Meaning This is an external user-defined alarm. The alarm is defined by the user in a HW database. Supplementary information fields
Instructions The operation depends on what kind of alarm is used as external alarm no. 19. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
DN99580892
Id:0900d805809d5c0d Confidential
31
7420 EXTERNAL AL 20
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
21 7420 EXTERNAL AL 20 Meaning This is an external user-defined alarm. The alarm is defined by the user in a HW database. Supplementary information fields
Instructions The operation depends on what kind of alarm is used as external alarm no. 20. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
32
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7421 EXTERNAL AL 21
22 7421 EXTERNAL AL 21 Meaning This is an external user-defined alarm. The alarm is defined by the user in a HW database. Supplementary information fields
Instructions The operation depends on what kind of alarm is used as external alarm no. 21. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
DN99580892
Id:0900d805809d5c0d Confidential
33
7422 EXTERNAL AL 22
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
23 7422 EXTERNAL AL 22 Meaning This is an external user-defined alarm. The alarm is defined by the user in a HW database. Supplementary information fields
Instructions The operation depends on what kind of alarm is used as external alarm no. 22. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
34
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7423 EXTERNAL AL 23
24 7423 EXTERNAL AL 23 Meaning This is an external user-defined alarm. The alarm is defined by the user in a HW database. Supplementary information fields
Instructions The operation depends on what kind of alarm is used as external alarm no. 23. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
DN99580892
Id:0900d805809d5c0d Confidential
35
7424 EXTERNAL AL 24
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
25 7424 EXTERNAL AL 24 Meaning This is an external user-defined alarm. The alarm is defined by the user in a HW database. Supplementary information fields
Instructions The operation depends on what kind of alarm is used as external alarm no. 24. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
36
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7425 EXTERNAL AL 25
26 7425 EXTERNAL AL 25 Meaning This is an external user-defined alarm. The alarm is defined by the user in a HW database. Supplementary information fields
Instructions The operation depends on what kind of alarm is used as external alarm no. 25. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
DN99580892
Id:0900d805809d5c0d Confidential
37
7426 EXTERNAL AL 26
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
27 7426 EXTERNAL AL 26 Meaning This is an external user-defined alarm. The alarm is defined by the user in a HW database. The effect of the alarm depends on the purpose that was configured for the user-defined alarm input in the BTS. Supplementary information fields
Instructions The operation depends on the type of alarm that is used as external alarm number 26. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
38
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7650 BASE STATION FAULTY
28 7650 BASE STATION FAULTY Meaning A critical fault (or faults) has occurred in the base station. Check the reason for the fault from the supplementary text field of the alarm. The effect of the fault on the functioning of the network element depends on the fault description. For more information, see base station fault descriptions in WCDMA RAN and Flexi Direct System Libraries. Supplementary information fields 1
rack (cabinet) number
2
shelf number
3
slot
4
type of unit
5
unit number
6
subunit number
For more information, see instructions on Alarm Structure. Instructions Verify the configuration of a BTS by checking the commissioning, cabling and correct installation of the units/modules at the BTS. Make sure the environment does not cause the fault. Before a unit/module is replaced at the BTS, the site should be reset to recover from any temporary faults which might have caused the malfunctioning of the unit/module. When an active alarm is a 'Start' alarm, a site reset is required to cancel the alarm. If the site reset or module block/unblock does not help, replace the faulty unit/module (see the source of the alarm and instructions fields of the corresponding alarms). Below is the list of BTS fault(s) which might have caused this alarm in BTS WN 8.0 release. In case of earlier SW release and in case you need more detailed fault descriptions refer to WCDMA RAN and Flexi Direct System Libraries. The BTS fault descriptions are also included in BTS SW release documentation. If that does not help,
DN99580892
Id:0900d805809d5c0d Confidential
39
7650 BASE STATION FAULTY
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
contact your local Nokia Siemens Networks representative.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
ATM faulty 45: EFaultId_ATM_SFN_PollingTimeoutAl A WAM internal failure. 1. If ping to the BTS is working, restart the BTS remotely. 2. Ping the BTS. If it is not working but ping to the AXC is working, then restart the AXC remotely so that the BTS is also restarted automatically. 3. Ping the AXC. If it is not working, visit the site and restart the BTS. If this does not help, replace the alarming WAM unit.
FAULT NAME FAULT ID
: ATM processor faulty : 590: EFaultId_AtmMcuBrokenAl 594: EFaultId_SfnIrqFailureAl MEANING : UltraSite, MetroSite, MetroSite 50, Triple-mode: There is a fault in the WAM processor SFN interrupt or the SFN is not being updated in the WSPC MCU. There is a MCU failure in the WAM or the ATM loop test at start-up has failed. FlexiBTS: There is such a fault in the FSM that the SFN is not being updated in the FSP MCU. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode: 1. If ping to the BTS is working, restart the BTS remotely. 2. Ping the BTS. If it is not working but ping to the AXC is working, restart the AXC remotely so that the BTS is also automatically restarted. 3. Ping the AXC. If it is not working, visit the site and restart the BTS. If this does not help, replace the alarming WAM unit. FlexiBTS: 1. Reset the BTS. 2. If the BTS reset does not help, change the alarming module.
FAULT NAME FAULT ID MEANING
: Antenna link is down : 476: EFaultId_Rp3BusError : Antenna (RP3) link is down: transmitter or receiver drops from synchronization. INSTRUCTIONS: Note! Perform the steps below in the listed order until the fault disappears: FlexiBTS: 1. If the alarming module is the Extension System Module (FSM2), restart it. If the alarming module is the System Module (FSM1), restart the BTS. 2. If that does not help, replace the alarming FSM.
40
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7650 BASE STATION FAULTY
FlexiLiteBTS: 1. Reset the BTS. 2. Replace the Flexi Lite BTS. UltraSite/EUBB: 1. If the alarming unit is WSPF, or if all WSPFs generate this alarm, restart the BTS. 2. If that does not help, replace the WSMF.
FAULT NAME FAULT ID MEANING
: BB bus message collision error : 2018: EFaultId_Muksu_StxPortCollAl : Routed RF baseband bus messages have collided and the data in the output baseband internal link is lost because the baseband bus is incorrectly configured. INSTRUCTIONS: 1. Check antenna mapping to the local cells in the commissioning file. 2. Check the cables between the System Module and RF Module. 3. Replace the alarming module.
FAULT NAME FAULT ID MEANING
: BB bus message in the wrong slot : 2057: EFaultId_MuksuMsgInWrongSlotAl : Baseband bus message multiplexing slot for the message is not possible to be fulfilled. INSTRUCTIONS: 1. Check antenna mapping to the local cells in the commissioning file. 2. Check the cables between the System Module and RF Module. 3. Replace the alarming module.
FAULT NAME FAULT ID MEANING
: BB bus reception error : 2044: EFaultId_TransuSMTimeOffAl : The master frame in the received RF BB frame is not in the correct place related to the internally generated master frame pulse. Either the frame has been set into the wrong place (PI delay) or the data itself is in the wrong place. INSTRUCTIONS: 1. If only one FSP in the BTS generates this alarm, the FSP is faulty. 2. If all FSPs generate this alarm, the FSM is faulty. 3. Block/unblock the FSM. 4. If that does not help, replace the faulty module (System Module).
FAULT NAME FAULT ID MEANING
DN99580892
: BB bus reception error (summing device) : 2016: EFaultId_Muksu_SMTimeOffAl : The master frame in the received baseband bus frame is not in the correct place related to the internally generated master frame pulse. Either the frame has been set in the
Id:0900d805809d5c0d Confidential
41
7650 BASE STATION FAULTY
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
wrong place (PI delay), or the data itself is in the wrong place. INSTRUCTIONS: FlexiBTS: 1. Check the cables between the Master System Module and RF Module/Extension System Module. 2. Replace the unit causing the fault (Master System Module, Extension System Module, RF Module, FBIA). UltraSite/EUBB: 1. Replace the unit causing the fault (WSPF, WSMF).
FAULT NAME FAULT ID MEANING
: BB bus transmission error : 2017: EFaultId_Muksu_SRx10b8bAl : A decoding error has been detected in the baseband internal link. The data packet is lost or the content is corrupted. This situation is also triggered when the links do not synchronize with each other. INSTRUCTIONS: FlexiBTS: 1. Check the cables between the Master System Module and RF Module/Extension System Module. 2. Replace the alarming unit (System Module). UltraSite/EUBB: 1. Replace the alarming unit (WSMF).
FAULT NAME FAULT ID MEANING
: BOFU Post failed : 4021: EFaultId_BOFU_Post_failedAl : The unit or module has been tested during BTS power-on self test (POST) and a failure has been detected. INSTRUCTIONS: 1. Block/unblock the alarming unit/module. 2. Remove/reinsert the alarming unit/module. 3. Replace the alarming unit/module.
FAULT NAME FAULT ID MEANING
: BTS blocked : 50: EFaultId_BTSBlockedAl : The BTS is blocked with BTS Site Manager. The meaning of the fault is to avoid alarms that may be raised during a BTS maintenance task. INSTRUCTIONS: To cancel the alarm, unblock the BTS. Unblocking of the BTS causes a site reset.
FAULT NAME FAULT ID MEANING
: BTS config error (WSMA and WSMB can not coexist) : 55: EFaultId_WsmaWsmbVersionConflictAl : WSMA and WSMB units are detected in the same cabinet. They cannot coexist in the BTS. INSTRUCTIONS: Replace the conflicting unit WSMA with the WSMB, or vice versa.
42
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
FAULT NAME FAULT ID
7650 BASE STATION FAULTY
BTS configuration not supported 4097: EFaultId_BtsConfNotSupportedAl FSP does not support requested BTS configuration. Note! Perform the steps below in the listed order until the fault disappears. 1. Change BTS configuration. 2. Reset BTS.
: BTS file error
: 1802: EFaultId_FileRequestFlashAl 1803: EFaultId_FileParsingFailedAl 1866: EFaultId_RulesMissingAl 1867: EFaultId_RulesParsingAl MEANING : UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: The BTS unit properties data is invalid or missing. FlexiBTS: The BTS module properties data or optical interface FPGA file is invalid or missing. The FSP MCU SW file is invalid or missing. FlexiLiteBTS: The BTS properties data or optical interface FPGA file is invalid or missing. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: 1. Download two different SW packages so that the faulty file is removed from the BTS. 2. Download the SW again. 3. If the fault still exists after 10 minutes, replace the alarming unit. FlexiBTS, FlexiLiteBTS: 1. Download two different SW packages so that the faulty file is removed from the BTS. 2. Download the SW again. 3. Replace the System Module.
FAULT NAME FAULT ID MEANING
: BTS file error : 136: EFaultId_TcomConfFileAl : Telecom configuration file(s) are invalid, missing, or not accessible. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: 1. Download two different SW packages so that the faulty file is removed from the BTS. 2. Download the SW again. 3. If the fault still exists after 10 minutes, replace the alarming unit. FlexiBTS:
DN99580892
Id:0900d805809d5c0d Confidential
43
7650 BASE STATION FAULTY
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
1. Download two different SW packages so that the faulty file is removed from the BTS. 2. Download the SW again. 3. Replace the System Module or FBIA.
FAULT NAME FAULT ID MEANING
: BTS internal SW management problem : 3090: EFaultId_BtsInternalSwManagementProblem : A software update to a unit/module or subassembly has failed, or a corrupted SW file has been detected in the FLASH. INSTRUCTIONS: Note: Perform the steps below in the listed order. FlexiBTS: 1. Check other active BTS faults. If the ROM disk is corrupted, change the alarming module. 2. Reset the RF Module and/or FBIA and/or System Module, depending on the alarm source: a. Reset the RF Module by blocking/unblocking it. b. Reset the FBIA by blocking/unblocking it. c. Reset the System Module. 3. Update and activate the SW to the BTS. 4. Check the SW files. 5. Replace the alarming module/unit. UltraSite/EUBB: 1. Check other active BTS faults. If the ROM disk is corrupted, change the alarming unit. 2. Reset the alarming unit. 3. Update and activate the SW to the BTS. 4. Check the SW files. 5. Replace the alarming unit. FlexiLiteBTS: 1. Reset the and/or DSP and/or CC&T, depending on the alarm source. 2. Update and activate the SW to the BTS. 3. Check the SW files. 4. Replace the alarming Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: BTS is uncommissioned : 4030: EFaultId_NoCommDataAl : Commissioning file download has not started from BTS Site Manager nor from NetAct during autoconfiguration. INSTRUCTIONS: 1. Make sure that autoconfiguration is enabled in NetAct. 2. Check the autoconnection/autoconfiguration information with BTS Site Manager. 3. Load the correct commissioning file to BTS.
FAULT NAME FAULT ID MEANING
44
: Baseband Bus failure : 3020: EFaultId_BaseBandBusFailure : The BTS has detected an abnormal operation or a failure in
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7650 BASE STATION FAULTY
the BTS internal baseband bus. The failure cannot be pointed to a specific unit/module but there are several possible fault sources. INSTRUCTIONS: Note: Perform the steps below in the listed order. FlexiBTS: 1. Check other active BTS alarms and act accordingly. 2. Check the cables between the System Module and RF Module/Extension System Module. 3. Reset the RF Module and/or System Module, depending on the alarm source: a. Reset the RF Module by blocking/unblocking it. b. Reset the Extension System Module by blocking/unblocking it. c. Reset the master System Module. 4. Replace the alarming RF Module/Extension System Module. 5. If the master System Module is the source or replacing the RF Module/Extension System Module does not clear the fault situation, replace the alarming master System Module. UltraSite/EUBB: 1. Check other active BTS alarms and act accordingly. 2. Reset the alarming unit. 3. Check the cables in backplane. 4. Replace the alarming unit. FlexiLiteBTS: 1. Check other active BTS faults and act accordingly. 2. Reset the BTS by blocking/unblocking it. 3. Replace the Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: Baseband bus configuration of was rejected : 1811: EFaultId_BbBus_ConfFailedAl : The baseband bus related configuration of was rejected by the HW, SW, DSP, or LTX. INSTRUCTIONS: Replace the alarming module. FlexiLiteBTS: Note! Perform the steps below in the listed order until the fault disappears: 1. Restart the BTS 2. Replace the FlexiLiteBTS unit
FAULT NAME FAULT ID MEANING
: Baseband reference clock missing (WCI) : 1006: EFautlId_BaseBandReferenceClkMss : The WCI does not deliver the Baseband Reference Clock (BRCLK) for the relevant units, because either the transceiver circuit in the WSC or the bus is faulty, or the WSC does not distribute the clock source. INSTRUCTIONS: You have two alternative procedures: 1. If there is only one clock unit in the cabinet, replace the WSC. 2. If Step 1 does not help, replace the WCI.
DN99580892
Id:0900d805809d5c0d Confidential
45
7650 BASE STATION FAULTY
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
OR 1. If there are two clock units in the cabinet, replace the WCI. 2. If Step 1 does not help, replace both WSC units.
FAULT NAME FAULT ID MEANING
: Baseband reference clock missing (WSC) : 910: EFaultId_DualWscBrclkMss : The WSC is not able to deliver the clock signals required by the other units. INSTRUCTIONS: Replace the WSC.
FAULT NAME FAULT ID MEANING
: Boot configuration inconsistency detected : 4102: EFaultId_BootConfigurationInconsistencyAl : During SW update it has been detected that configurations of active and passive SW in HW unit are the same. Active and passive SW configurations are compared: - before SW download, - during SW activation, before active and passive SW switch, - during start-up. INSTRUCTIONS: Replace the faulty unit.
FAULT NAME FAULT ID MEANING
: Commissioning error: : 3060: EFaultId_CommissioningError : Some of the commissioning parameters are either missing or faulty. Or there is a mismatch between them. INSTRUCTIONS: Note: Perform the steps below in the listed order. 1. Check the commissioning parameters with the BTS Site Manager Commissioning Wizard. 2. Load the correct commissioning file to the BTS.
FAULT NAME FAULT ID MEANING
: Communication failure : 1806: EFaultId_CommunicationFailureAl : Communication with the application failed. The application has not replied to the message that has been sent/resent to it. INSTRUCTIONS: FlexiBTS: 1. Make sure that the unit/module is properly connected. If the unit/module LED does not light up, the unit/module is faulty. Check the alarming unit/module. 2. Check the fault history. FlexiLiteBTS: 1. If the Flexi Lite BTS LED does not light up, the BTS is faulty. Check the Flexi Lite BTS. 2. Check the fault history.
46
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7650 BASE STATION FAULTY
FAULT NAME FAULT ID MEANING
: Communication failure : 458: EFaultId_VcpError : An internal communication fault in the decoding process in the module, for example, a decode co-processor error. INSTRUCTIONS: 1. Reset the alarming unit/module. 2. Replace the alarming unit/module.
FAULT NAME FAULT ID
: Communication failure inside WSP : 414: EFaultId_McbspMessagePoolExhausted 446: EFaultId_McbspSwsError MEANING : An internal communication failure between the DSP processors. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode: 1. Block the alarming WSP. 2. The fault might be in the WTR or WPA (see Troubleshooting instructions). Otherwise, check for other alarms. If the " autonomous reset as recovery action" alarm has occurred for the alarming WSP, replace the alarming WSP unit. FlexiBTS: 1. If only one FSP in BTS generates this alarm, the FSP is faulty. 2. If all FSPs generate this alarm, the FSM is faulty. 3. Block/unblock the FSM. 4. If that does not help, replace the faulty module (System Module). UltraSite/EUBB: 1. If only one WSPF in the BTS generates this alarm, the WSPF is faulty. 2. If all WSPFs generate this alarm, the BTS is faulty. 3. Block/unblock the BTS. 4. If that does not help, replace the faulty module.
FAULT NAME FAULT ID MEANING
: Configuration error: : 3070: EFaultId_ConfigurationError : There is an incompatibility problem in the BTS HW/SW versions or the HW/HW configuration. Another possibility is that there is a mismatch between the BTS configuration and the RNC/Flexi Direct RNC parameters. INSTRUCTIONS: Note: Perform the steps below in the listed order. 1. Check the installed HW/SW version compatibility and the HW compatibility with the current BTS configuration. 2. Check that the BTS cell parameters from the RNC/Flexi Direct RNC match the BTS HW configuration (for example frequency, power). 3. Check the RNC/Flexi Direct RNC BTS faults for the alarming local cell (LCR).
DN99580892
Id:0900d805809d5c0d Confidential
47
7650 BASE STATION FAULTY
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
4. Recommission the BTS to ensure that all parameters are correctly configured.
FAULT NAME FAULT ID MEANING
: Configuration file is not supported : 4035: EFaultId_ConfigurationFileNotSupportedAl : BTS software does not support the commissioning file downloaded to the BTS. INSTRUCTIONS: 1. Check and correct the contents of the commissioning file. 2. Download the corrected commissioning file to the BTS and reset it.
FAULT NAME FAULT ID MEANING
: Connection to transmission broken : 1829: EFaultId_ConnToTransBrokenAl : UltraSite, MetroSite, MetroSite 50, Triple-mode: The AXC is missing, data or states are corrupted in the ATM, or there are possible hardware or transmission related failures. FlexiBTS: Data or states are corrupted in the ATM, or there are possible hardware or transmission related failures. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode: 1. Check the transmission connections. 2. If the transmission type is the AXC, reset the WAM. 3. If that does not help, replace the alarming unit. FlexiBTS: 1. Check the transmission connections. 2. Reset the site. 3. If that does not help, replace the alarming System Module.
FAULT NAME FAULT ID MEANING
: DSC-bus failure : 208: EFaultId_DscNodeBlockedAl : There is a failure in the bus between the WAM and WSP (DSC-bus), which means that messages do not get through via that DSC-bus. INSTRUCTIONS: 1. Block/unblock the alarming unit. 2. Replace the alarming unit.
FAULT NAME FAULT ID MEANING
: DSC-bus failure : 597: EFaultId_DscFaultAl : There are communication problems between the WAM and WSP. This alarm may occur if the WSP is hot removed or the WSP crashes. INSTRUCTIONS: If the failure still exists after the site reset, replace the WAM unit.
48
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7650 BASE STATION FAULTY
FAULT NAME FAULT ID MEANING
: DSP accelerator initialization failure : 2302: EFaultId_RsaInitializationError : There is a signal processing (DSP) related malfunction in the BTS. This might affect the signal processor receiver functionality processed by the alarming unit/module. INSTRUCTIONS: FlexiBTS: 1. If the alarming module is the Extension System Module (FSM2), restart it. If the alarming module is the System Module (FSM1), restart the BTS. 2. If that does not help, replace the alarming FSM or unit. UltraSite/EUBB: 1. If the alarming unit is WSPF, restart it. If all WSPFs generate this alarm, restart the BTS. 2. If that does not help, replace the alarming unit. Restart can be done by BTS block/unblock, system module block/unblock from BTS SEM and from NetAct to reset BTS.
FAULT NAME FAULT ID MEANING
: DSP failure in radiolink creation : 129: EFaultId_DspHoldAl : Radio link creation has been failing repeatedly because of DSP rejection. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode: 1. Block/unblock the alarming unit. 2. Replace the alarming unit. UltraSite/EUBB: 1. Block/unblock the EUBB subrack. 2. Replace the alarming unit. FlexiBTS: If the faulty FSP is in the extension module, block/unblock the extension module, otherwise block/unblock the BTS.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
DSP mode change failed 139: EFaultId_DspModeChangeFailAl DSP configuration to correct mode was not successful. Replace the alarming module/unit.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
DSP overheated 4101: EFaultId_DspOverheatingAl DSP overheating was detected during DSP initialization. 1. Check the fans and ensure that the ambient temperature on the site is acceptable. 2. If that does not help, replace the alarming FSP module.
DN99580892
Id:0900d805809d5c0d Confidential
49
7650 BASE STATION FAULTY
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
Downlink data buffer synchronization failure 2031: EFaultId_Transu_DlDbSynchChAl The downlink data buffer has lost synchronization. 1. If only one FSP in the BTS generates this alarm, the FSP is faulty. 2. If all FSPs generate this alarm, the FSM is faulty. 3. Block/unblock the FSM. 4. If that does not help, replace the faulty module (System Module).
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
FSP in resetting state 4068: EFaultId_FspResetAl FSP is undergoing a cold reset. Note! Perform the steps below in the listed order until the fault disappears: FlexiBTS: 1. Reset the BTS. 2. Replace the faulty module/unit. FlexiLiteBTS: 1. Reset the BTS. 2. Replace the Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: FSP overheating : 4077: EFaultId_FspOverheatingAl : Temperature on the FSP board exceeds the critical threshold value. INSTRUCTIONS: 1. Check the fans and ensure that the ambient temperature on the site is acceptable. 2. If that does not help, replace the alarming module.
FAULT NAME FAULT ID MEANING
: FSP/WSP Frame synchronisation failed : 1822: EFaultId_Fr_SyncAl : The frame synchronization burst, SFN or SFCLK signal from the FCM/WSPF is missing. INSTRUCTIONS: 1. Reset the site. 2. If that does not help, replace the System Module.
FAULT NAME FAULT ID MEANING
: Failure in optical RP3 interface : 3030: EFaultId_FailureInOptical_Rp3Interface : The BTS has detected an abnormal operation or a failure in an optical RP3 interface between two modules. The failure cannot be pointed to a specific module but there are several possible fault sources. INSTRUCTIONS: Note: Perform the steps below in the listed order until the alarm disappears.
50
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7650 BASE STATION FAULTY
1. Check the other active BTS alarms and act accordingly. 2. Check the cables between the System Module and RF Module/Extension System Module. Note that dirty optical connectors may cause the signal level to drop too low. 3. Depending on the alarm source, reset the RF Module, Extension System Module and/or System Module by blocking/unblocking it. 4. Replace the alarming module's Small Form Factor Pluggable (SFP). Check also the SFP in the other end and replace it, if needed. 5. Replace the alarming RF Module/Extension System Module. 6. If the System Module is the only alarming source or replacing the RF Module/Extension System Module does not clear the fault situation, replace the alarming System Module.
FAULT NAME FAULT ID MEANING
: Failure in replaceable baseband unit : 3003: EFaultId_FbiaFailureAl : The BTS has detected an abnormal operation or a failure in the BTS replaceable baseband unit. INSTRUCTIONS: Note: Perform the steps below in the listed order until the BTS fault indication disappears. 1. Check the other active BTS faults and act accordingly. 2. Check if the plug-in type baseband unit is installed correctly. 3. Reset the alarming baseband unit. 4. Replace the alarming baseband unit.
FAULT NAME FAULT ID MEANING
: Fatal OSE Error : 418: EFaultId_OseFatalErr : The operating system (OSE) goes into the error handler with a fatal status. The cause can be, for example, out of memory situation. If only one FSP in BTS generates this fault, there is a malfunction in one of the FSP submodules. If all FSPs generate this fault, there is a malfunction in the FSM. INSTRUCTIONS: FlexiBTS: Note! Perform the steps below in the listed order until the fault disappears. 1. Reset the System Module. 2. Replace the System Module. FlexiLiteBTS: Note! Perform the steps below in the listed order until the fault disappears. 1. Reset the FlexiLiteBTS 2. Replace the FlexiLiteBTS UltraSite/EUBB: 1. If only one WSPF in BTS generates this fault, the WSPF
DN99580892
Id:0900d805809d5c0d Confidential
51
7650 BASE STATION FAULTY
is 2. 3. 4.
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
faulty. If all WSPFs generate this fault, BTS is faulty. Block/unblock BTS. If that does not help, replace the faulty module.
FAULT NAME FAULT ID
: Fault between WAM and WSP SFN (WSP) : 412: EFaultId_LostFrameSync 428: EFaultId_SystemFrameNumberParity MEANING : UltraSite, MetroSite, MetroSite 50, Triple-mode: Synchronization between the WAM and WSP is lost. FlexiBTS: Synchronization between the FCM and FSP/FBIA is lost. UltraSite/EUBB: Synchronization between the WAMF and WSPF is lost. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode: 1. If only one WSP in the cabinet generates this alarm, the WSP is faulty. 2. If all WSPs in a subrack generate this alarm, the WAM is faulty. 3. If all WSPs generate this alarm, the WSC/WMC is faulty. Otherwise, check for other alarms. If the " autonomous reset as a recovery action" alarm has occurred for the faulty WSP, replace the faulty WSP unit. FlexiBTS: 1. If only one FSP/FBIA in the BTS generates this alarm, the FSP/FBIA is faulty. 2. If all FSPs generate this alarm, the FSM is faulty. 3. Block/unblock the FSM. 4. If that does not help, replace the faulty module (System Module) or faulty FBIA. UltraSite/EUBB: 1. If only one WSPF in the BTS generates this alarm, the WSPF is faulty. 2. If all WSPFs generate this alarm, the BTS is faulty. 3. Block/unblock the BTS. 4. If that does not help, replace the faulty module.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
FAULT NAME FAULT ID
MEANING
52
Fault in ATM interface 309: EFaultId_AtMuxAl The WAM ATM interface is not responding correctly. 1. Block/unblock the alarming unit. This resets the BTS. 2. If that does not help, replace the alarming unit.
: Fault in ATM interface : 591: EFaultId_SarChipBrokenAl 592: EFaultId_UxAsicAl 593: EFaultId_AtmHostBrokenAl : WAM ATM interface, AXC or CIF bus failure. The AXC may have
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7650 BASE STATION FAULTY
been reset. WAM processor failure. INSTRUCTIONS: 1. Block/unblock the alarming unit. This will reset the BTS. 2. Swap the WAM units between subracks and check if the alarm follows the unit. Replace the alarming WAM unit. 3. Check the AXU. 4. Check the backplane connection between the WAM and AXU.
FAULT NAME FAULT ID
: Fault in O&M and DSP SW interface : 42: EFaultId_ WSPC_PPC_SFN_PollingTimeoutAl 43: EFaultId_DSP_PollingTimeoutAl MEANING : UltraSite, MetroSite, MetroSite 50, Triple-mode: Communication failure between the WAM and DSP. FlexiBTS: Communication failure between the FCM and FSP/FBIA. UltraSite/EUBB: Communication failure between the WSMF and WSPF. FlexiLiteBTS: Communication failure between the SCR and FSP. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode: 1. Block/unblock the alarming unit. 2. Replace the alarming unit. UltraSite/EUBB: 1. Block/unblock the EUBB subrack. 2. Replace the alarming unit. FlexiBTS: 1. Block/unblock the alarming module. 2. Replace the system module/plug-in FSP. FlexiLiteBTS: 1. Block/unblock Flexi Lite BTS. 2. Replace the Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: File System access failed : 4088: EFaultId_FileSystemAccessFailedAl : File System access operation like: - File System mounting - file opening failed INSTRUCTIONS: Update SW to the BTS, unless it is automatically updated by NetAct.
FAULT NAME FAULT ID MEANING
: Firmware SW mismatch : 2056: EFaultId_SwMismatchAl : The SW update to the BTS has failed or the BTS SW got corrupted. INSTRUCTIONS: 1. Switch to the latest active BTS configuration. 2. Retry the SW update.
DN99580892
Id:0900d805809d5c0d Confidential
53
7650 BASE STATION FAULTY
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
FAULT NAME FAULT ID MEANING
: Frame clock deviation fault : 2014: EFaultId_Muksu_SFCRCompDevAl : Synchronization to the clock control unit frame pulse has been achieved earlier but it differs from the currently received frame pulse. The internally generated frame clock might have drifted. INSTRUCTIONS: FlexiBTS: 1. Check the cables between the System Module and RF
Module/Extension System Module. 2. Reset the alarming System Module. 3. Replace the alarming System Module. UltraSite/EUBB: 1. Reset the alarming WSMF. 2. Replace the alarming WSMF.
FAULT NAME FAULT ID
: Incompatible SW version detected : 23: EFaultId_IncompatibleSwVersionAl 24: EFaultId_ObsoleteSwVersionAl MEANING : A new unit with incompatible SW has probably been inserted in the BTS. INSTRUCTIONS: Update compatible SW to the BTS (check the SW versions to see the active SW version, and update the active SW version), unless it is automatically updated by NetAct. NOTE: If also fault 10:EFaultId_NoConnectionToUnitAl is active on the source unit then SW update should be postponed until fault 10:EFaultId_NoConnectionToUnitAl is cancelled. Related BTS - AXC interface: check the SW version of the BTS and AXC, and update compatible SW to the AXC or BTS.
FAULT NAME FAULT ID
: Incompatible unit detected : 83: EFaultId_WtraWsmaWspaNotSupportedInCabinetAl 91: EFaultId_WrongUnitTypeInCabinetAl MEANING : An unsupported unit (for example a WSMA, WTRA, WSPA, WMCM or WTRB) has been detected in the cabinet. INSTRUCTIONS: Replace the unsupported unit with a unit of the correct type.
FAULT NAME FAULT ID MEANING
: Internal MTU configuration failure : 4025: EFaultId_MtuConfigurationFailureAl : Internal Maximum Transfer Unit (MTU) configuration failed on FCM or FSP/FBIA. INSTRUCTIONS: 1. Reset the alarming System Module or unit. 2. Replace the alarming System Module or unit
54
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7650 BASE STATION FAULTY
FAULT NAME FAULT ID MEANING
: Internal communication error : 4087: EFaultId_InternalCommunicationErrorAl : Reliable message delivery service is not able to deliver an internal message to a recipient (FSP or FSM), and sends an asynchronous notification to the message sender about the unreachable recipient. INSTRUCTIONS: 1. Make sure that the unit/module is properly connected. 2. Reset the alarming unit. 3. Replace the alarming unit.
FAULT NAME FAULT ID MEANING
: Internal delay measurement failure : 1893: EFaultId_InternalDelayMeasurementFailureAl : An autonomous internal delay measurement has failed. The TCOM was not able to measure the internal delay for a cell for any of the RAKEs in a certain BB unit. INSTRUCTIONS: None
FAULT NAME FAULT ID MEANING
: Invalid configuration file : 4036: EFaultId_InvalidConfigurationFileAl : The commissioning file is missing, or an incorrect commissioning file has been detected during a BTS startup as follows: "Validation failed because of incompatible data" INSTRUCTIONS: 1. Check and correct the contents of the commissioning file. 2. Recommission the BTS with a valid commissioning file.
FAULT NAME FAULT ID MEANING
: Master unit has lost connection to the slave unit : 4019: EFaultId_KeepAliveStatusErrorAl : Connection to the DSP submodule has been lost or the submodule reports an error situation. INSTRUCTIONS: Note! Perform the steps below in the listed order until the fault disappears: FlexiBTS: 1. Reset the BTS. 2. Replace the faulty module/unit. FlexiLiteBTS: 1. Reset the BTS. 2. Replace the Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: Message routing problem in receiver (RX) : 2058: EFaultId_MuksuMsgRoutingFailedAl : If a message does not get routed an interrupt is generated. Considered normal when Faradays are starting up and RP3 sync done. INSTRUCTIONS: If RF is the source:
DN99580892
Id:0900d805809d5c0d Confidential
55
7650 BASE STATION FAULTY
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
1. Check antenna mapping to the local cells in the commissioning file. 2. Check the cables between the System Module and RF Module. 3. Replace the alarming module. If FSP is the source: Baseband reset should be performed.
FAULT NAME FAULT ID MEANING
: Module dangerously overheating : 4071: EFaultId_SysDangerouslyOverheatAl : Highest validated temperature value on FSP board exceeds the threshold value. INSTRUCTIONS: Note! Perform the steps below in the listed order. 1. Check the fans and ensure that the ambient temperature on the site is acceptable. 2. If that does not help, replace the alarming module.
FAULT NAME FAULT ID MEANING
: No baseband capacity for common channels : 132: EFaultId_NoBBCapasityForCommonChannels : There is not enough common channel capacity to set up any cells to the BTS, because Efficient Baseband or Full Baseband HSDPA is allocated (last WSP/FSP card is fully reserved). INSTRUCTIONS: None
FAULT NAME FAULT ID MEANING
: No connection to AXU : 21: EFaultId_AxuResetAl : The master WAM detected that the AXU does not respond to polling messages. INSTRUCTIONS: 1. Check for alarms on the AXC. 2. Restart the AXC remotely. This will also cause a BTS restart. 3. Change the alarming AXC unit.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
FAULT NAME FAULT ID MEANING
56
No connection to BTS transport submodule 3511: EFaultId_NoConnectionToFtAl The connection to the BTS transport submodule is lost. Note: Perform the steps below in the listed order. 1. Reset the site. 2. Replace the Transport submodule, which is located inside the System Module.
: No connection to unit : 10: EFaultId_NoConnectionToUnitAl 4052: EFaultId_ConnectionToUnitLostAl : Connection to a unit that belongs to the BTS configuration
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7650 BASE STATION FAULTY
has been lost or FSP cannot be detected. INSTRUCTIONS: FlexiBTS: 1. Make sure that the module is properly connected. If the module LED does not light up, the module is faulty. Check the alarming module. In case of two FSM-r3, check also SRIO cable connection between the system modules. 2. Check the fault history. FlexiLiteBTS: Check the fault history. UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: 1. Check the fault history, alarming unit and subrack. 2. If the SW has been updated recently, reload the SW. 3. If the WAF or WIC is alarming, try recommissioning the site. 4. Make sure that the unit is properly connected. If the unit LED does not light up, the unit is faulty. The fault might also be in the WPS unit or backplane. 5. Check the power cables, connectors, and the I2C bus cables. Cancel alarms: Removing and inserting the WIC, WSM or primary WAM causes a site reset. If both WSCs are removed, inserting the first removed WSC back into the cabinet causes a site reset. If the 7650 BASE STATION FAULTY alarm is issued, reset the site. First, try to reset the site with the software. If that does not help, replace the alarming unit. If the WSMF unit is not present (replaced by WSMB)in BTS, alarming WSPFs are not used and should be removed from BTS. WSPFs can be removed, because without a WSMF unit BTS works as UltraSite not as EUBB.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
FAULT NAME FAULT ID MEANING
Not able to synchronize baseband bus with 1815: EFaultId_BbBus_SyncFailedAl The baseband bus synchronization towards failed. FlexiLite: Replace the alarming module/plug-in FSP. FlexiLiteBTS: Replace the Flexi Lite BTS.
: Optical Interface Frame clock faulty : 2003: EFaultId_OIC_CleanerLockAl
: The VCXO does not get correct control voltage from the PLL filter of the clock cleaner. This may happen because of an unsuccessful clock recovery in the optical interface because of a missing or degraded input signal. INSTRUCTIONS: 1. Block/unblock the System Module.
DN99580892
Id:0900d805809d5c0d Confidential
57
7650 BASE STATION FAULTY
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
2. Replace the System Module.
FAULT NAME FAULT ID
: Optical interface data/control/Ethernet buffer full : 2006: EFaultId_OIC_DBRxFullAl 2007: EFaultId_OIC_DBTxFullAl 2008: EFaultId_OIC_CBRxFullAl 2009: EFaultId_OIC_CBTxFullAl 2010: EFaultId_OIC_EBFullAl MEANING : The RP3 or Ethernet buffering is not working and the buffer becomes full. The optical device is malfunctioning. The fault might be generated because of synchronization problems or incorrect initialization. INSTRUCTIONS: Swap the alarming and working links. Then check where the alarm is reported. If the alarming link remains the same, replace the System Module. If the alarming link changes, replace the RF Module behind that link.
FAULT NAME FAULT ID
: Oven oscillator clock missing : 903: EFaultId_OcxoClkMss 911: EFaultId_DualWscOcxoClkMss MEANING : The WSC is not able to deliver the clock signals required by the other units. INSTRUCTIONS: Replace the clock unit.
FAULT NAME FAULT ID MEANING
: Oven oscillator clock missing : 1819: EFaultId_OcxoClkMissAl : The output signal of the OXCO is missing and the FCM/FCT/SCR cannot deliver the 30.72 MHz System Clock required by the other units. INSTRUCTIONS: 1. Block/unblock the System Module. 2. Replace the System Module.
FAULT NAME FAULT ID MEANING
: Oven oscillator heating failure : 1817: EFaultId_Ov_Osc_HeatAl : The OCXO warm-up takes too long and the OCXO does not become active within a period of eight minutes from the power-on. The ambient temperature can also be too low or it changes too fast. INSTRUCTIONS: FlexiBTS: Replace the alarming module. FlexiLiteBTS: Replace the FlexiLiteBTS.
FAULT NAME FAULT ID MEANING
58
: Oven oscillator missing pulse : 1820: EFaultId_OcxoPulseMissingAl : The output signal of the OXCO has some problems and one or
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7650 BASE STATION FAULTY
more clock pulses are missed. INSTRUCTIONS: 1. Block/unblock the System Module. 2. Replace the System Module.
FAULT NAME FAULT ID MEANING
: PLL status not locked : 4010: EFaultId_PLLStatusNotLockedAl : BTS monitors the FSP/FBIA/WSPF/WSMF PLL (Phase-Locked Loop) lock status and PLL locking fails. INSTRUCTIONS: FlexiBTS: 1. Block/unblock the FSM/FBIA. 2. If that does not help, replace the FSM/FBIA. UltraSite/EUBB: 1. Block/unblock the WSMF. 2. If that does not help, replace the WSMF. 3. Block/unblock the WSPF. 4. If that does not help, replace the WSPF.
FAULT NAME FAULT ID MEANING
: POST test failed : 69: EFaultId_Post_test_failedAl : A failure in the unit/module has been detected during the BTS power-on self test (POST). INSTRUCTIONS: 1. Block/unblock the alarming unit/module. 2. Remove/re-insert the alarming unit/module. 3. Replace the alarming unit/module. FlexiLiteBTS: 1. Replace the FlexiLiteBTS.
FAULT NAME FAULT ID MEANING
: Parallel Interference Cancellation stream failure detected : 2310: EFaultId_PicStreamFailure : RACH RAKE sends this fault when Parallel Interference Cancellation stream failure is detected. INSTRUCTIONS: FlexiBTS: Note! Perform the steps below in the listed order until the fault disappears. 1. Reset the System Module. 2. Replace the System Module. UltraSite/EUBB: 1. If only one WSPF in the BTS generates this fault, the WSPF is faulty. 2. If all WSPFs generate this fault, the BTS is faulty. 3. Block/unblock the BTS. 4. If that does not help, replace the faulty module.
FAULT NAME FAULT ID MEANING
DN99580892
: Power unit output voltage fault : 1301: EFaultId_WpsPwrOutVoltage : The output voltage is too low or too high. Usually the reason for the fault is the unit itself but in
Id:0900d805809d5c0d Confidential
59
7650 BASE STATION FAULTY
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
some cases the reason can be the unit that the WPS feeds. If a short circuit occurs in the fed unit, it may affect the WPS and the "Output Voltage Fault" alarm is generated. INSTRUCTIONS: 1. Check the other active alarms. 2. Check the units that are supplied by the alarming WPS. 3. Check the backplane connectors and cables. 4. Replace the alarming WPS unit.
FAULT NAME FAULT ID MEANING
: R-bus error : 425: EFaultId_RbusError : UltraSite, MetroSite, MetroSite 50, Triple-mode: The bus between the WSP and WTR does not work. The R-bus errors are probably caused by a faulty WSM or WTR. FlexiBTS: Error in the FSP or in the connection between the FSP and FCM. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode: 1. If the WSM/WMC also generates an alarm from a WTR unit, check the WTR and WSM cable. 2. If there are no active WSM/WMC alarms, the reason for the alarm is a faulty WSM/WMC or WSP. 3. Run a WCDMA BTS loop test to locate the faulty unit. 4. If the WSP is faulty, block/unblock it. 5. Replace the faulty unit. FlexiBTS: 1. Check the cabling between the System Module and RF Module. 2. Check the active RF Module alarms and act accordingly. 3. Replace the faulty module (System Module).
FAULT NAME FAULT ID MEANING
: RP1 synchronization burst error : 2052: EFaultId_OicRp1FcbAl : A new RP1 Frame Clock Burst (FCB) burst/message has been received from the RP3-01 interface while processing the previous burst/message. INSTRUCTIONS: 1. Reset the alarming Extension System Module by blocking/unblocking it. 2. If that does not clear the fault situation, replace the alarming Extension System Module. 3. If the System Module is the only alarming source or replacing the Extension System Module does not clear the fault situation, replace the alarming System Module.
FAULT NAME FAULT ID MEANING
: SFN Signal error : 2036: EFaultId_Transu_SfnSignalAl : A system frame number reception fault, an illegal SFN value in uplink. INSTRUCTIONS: 1. If only one FSP in the BTS generates this alarm, the FSP is faulty.
60
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7650 BASE STATION FAULTY
2. If all FSPs generate this alarm, the FSM is faulty. 3. Block/unblock the FSM. 4. If that does not help, replace the faulty module (System Module).
FAULT NAME FAULT ID MEANING
: SFN synchronization failure : 41: EFaultId_WSPC_PPC_SFN_PollingSynchAl : UltraSite, MetroSite, MetroSite 50, Triple-mode: The WSP is not synchronized with the WAM. FlexiBTS: The FSP/FBIA is not synchronized with the FCM. FlexiLiteBTS: The FSP is not synchronizaed with the SCR UltraSite/EUBB: The WSPF is not synchronized with WSMF. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode: 1. Block/unblock the alarming unit. 2. Replace the alarming unit. UltraSite/EUBB: 1. Block/unblock the EUBB subrack. 2. Replace the alarming unit. FlexiBTS: 1. Block/unblock the alarming module. 2. Replace the system module/plug-in FSP. FlexiLiteBTS: 1. Reset the BTS 2. Replace the FlexiLiteBTS unit
FAULT NAME : SRIO chain configuration was rejected FAULT ID : 4015: EFaultId_Srio_ConfFailedAl MEANING : The platform SW rejected the baseband bus related SRIO configuration for Faraday core. INSTRUCTIONS: Replace the alarming unit/module.
FAULT NAME FAULT ID MEANING
: SRIO multicast configuration failed : 4066: EFaultId_SrioMulticastConfFailedAl : Response is not received or response is received with unsuccessful status for SRIO multicast configuration related messages. INSTRUCTIONS: Note! Perform the steps below in the listed order until the fault disappears. 1. Block/unblock the BTS. 2. Replace the alarming unit.
FAULT NAME FAULT ID
DN99580892
: SW fallback : 4082: EfaultId_FallbackDueToMaxResetLoopCounterValueAl 4083: EFaultId_FallbackDueToConfigurationDataMigrationFailureAl
Id:0900d805809d5c0d Confidential
61
7650 BASE STATION FAULTY
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
4085: EfaultId_FallbackDueToTransportRequestAl : 4082: Source unit has reached the maximum number of reset attempts, that is the source unit cannot successfully finish start-up after the SW update. 4083: Source unit requests SW fallback due to a critical problem that occurred in start-up after the SW update, that is configuration data migration failed. 4085: Transport SW on the source unit indicates a need for software fallback. INSTRUCTIONS: If the BTS is not automatically updated by NetAct and SW versions are inconsistent, update SW to the BTS with SW version running on BTS before SW update causing SW fallback. MEANING
FAULT NAME FAULT ID MEANING
: Starting temperature below minimum : 1827: EFaultId_StartTempBelowMinAl : BTS cannot start properly, because FSPs cannot be powered up at too cold conditions. INSTRUCTIONS: 1. Wait until the module is automatically heated to the required start-up temperature. 2. If the fault is active for more than 2 hours, check the environmental conditions of the site.
FAULT NAME FAULT ID MEANING
: Summing not enabled for message type : 2059: EFaultId_MuksuSummingNotEnabledAl : Summing checks headers of the messages to be summed. If the header is not any of the allowed types, no summing is performed and an empty message is sent instead. INSTRUCTIONS: If FCM is the source: Reset FCM unit.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
Summing service default initialization failed 4092: EFaultId_MurkkuDefaultInitFailedAl Summing service default configuration has failed 1. Reset the System Module. 2. If a reset does not resolve the fault situation, replace the System Module.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
Summing service release from reset failed 1891: EFaultId_MuksuReleaseFromResetFailedAl Summing service release from reset failed. 1. Reset the System Module. 2. If a reset does not resolve the fault situation, replace the System Module.
62
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
7650 BASE STATION FAULTY
Summing service release from reset failed 4081: EFaultId_MurkkuReleaseFromResetFailedAl Summing service release from reset failed. 1. Reset the System Module. 2. If a reset does not resolve the fault situation, replace the System Module.
FAULT NAME FAULT ID MEANING
: Synchronization failure : 2030: EFaultId_Transu_CompDevBbRfAl : The frame burst phase has moved compared to the internal counter. The FSM has already found the frame synchronization but the FSM frame clock does not match the FSM internal frame clock. INSTRUCTIONS: 1. If only one FSP in the BTS generates this alarm, the FSP is faulty. 2. If all FSPs generate this alarm, the FSM is faulty. 3. Block/unblock the FSM. 4. If that does not help, replace the faulty module (System Module).
FAULT NAME
: Synchronization failure in Optical Interface FAULT ID : 2005: EFaultId_OIC_SyncChAl MEANING : The RP3 channel has lost the frame synchronization state that it had achieved. INSTRUCTIONS: Swap the alarming and working links and then check where the alarm is now reported. If the alarming link remains the same, replace the System Module. If the alarming link changes, replace the RF Module behind that link.
FAULT NAME FAULT ID MEANING
: System Module failure : 3000: EFaultId_SystemModuleFailure : The Flexi BTS has detected an abnormal operation or a failure in the internal functionality of the System Module. The Flexi Lite BTS has detected an abnormal operation or a failure in the internal functionality of the BTS. INSTRUCTIONS: Note: Perform the steps below in the listed order. Flexi BTS: 1. Check cables between the modules and replace them if needed. 2. Reset the System Module. 3. Replace the System Module. Flexi Lite BTS: 1. Reset the BTS. 2. Replace the Flexi Lite BTS.
DN99580892
Id:0900d805809d5c0d Confidential
63
7650 BASE STATION FAULTY
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
FAULT NAME FAULT ID MEANING
: TRANSU synchronization error : 2045: EFaultId_TransuSyncAl : The RP3 TX/RX state machine or the T-bus receiver has changed its state. The synchronization is lost or the T-bus receiver has not synchronized. INSTRUCTIONS: 1. If only one FSP in the BTS generates this alarm, the FSP is faulty. 2. If all FSPs generate this alarm, the FSM is faulty. 3. Block/unblock the FSM. 4. If that does not help, replace the faulty module (System Module).
FAULT NAME FAULT ID MEANING
: Tbus receiver parity fault : 2027: EFaultId_Transu_TbusParityAl : Data or synchronization failure in the System Module, two antenna carriers are affected. INSTRUCTIONS: 1. If only one FSP in the BTS generates this alarm, the FSP is faulty. 2. If all FSPs generate this alarm, the FSM is faulty. 3. Block/unblock the FSM. 4. If that does not help, replace the faulty module (System Module).
FAULT NAME FAULT ID
: Telecom configuration failure : 109: EFaultId_TcomSlaveRegAl 110: EFaultId_UnitRnwConfigAl 111: EFaultId_TcomSlaveConfigAl 119: EFaultId_WspAllocationAl MEANING : Telecom slave configuration or registration failure. Unit RNW configuration failure. Telecom RNW reconfiguration failure. FlexiBTS: - FSP unit to FCM allocation failure - Faraday unit to FSP allocation failure Note that depending on the fault source, unit status might relate either to the state of particular carrier resource on FR module or FSP board on FCM, and may not be in line with the state of source HW unit. Or UltraSite, MetroSite, MetroSite 50, Triple-mode: WSP unit to WAM allocation failure. UltraSite/EUBB: Faraday unit to WSPF allocation failure. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: Block/unblock the alarming unit. If there was an internal failure, the unit needs to be blocked/unblocked to get it initialized/configured again. UltraSite/EUBB: If the alarming unit is WSPF, block/unblock
64
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7650 BASE STATION FAULTY
the EUBB subrack. FlexiBTS: If there was an internal failure, in the case of an FR, the module needs to be blocked/unblocked to get it initialized/configured again. FlexiBTS Rel2: If the alarming unit is FSPC, block/unblock the alarming module.
FAULT NAME FAULT ID MEANING
: Temperature alarm : 3040: EFaultId_TemperatureAlarm : The internal temperature of the RF Module or System Module
exceeds the threshold value, or the ambient temperature of the module(s) is beyond the specified limits. INSTRUCTIONS: Note: Perform the steps below in the listed order. 1. Check other BTS faults and act accordingly. 2. Check the ambient temperature of the BTS modules. If the ambient temperature is too high, make sure the airflow to the BTS modules is unobstructed, that is, the BTS modules are not covered with anything. If the ambient temperature is too low, it takes a while for the BTS modules to heat themselves to the threshold value. 3. Reset the alarming module/unit by blocking/unblocking it. 4. Replace the alarming module/unit.
FAULT NAME FAULT ID MEANING
: Ten consecutive Nacks received from a DSP at DCH setup : 149: EFaultId_DspNacksReceivedAl : One particular DSP Nacks DCH setup 10 times with cause "NotEnoughResources=10" or "AlreadyActivated_Allocated=22" within a 20 minute period. INSTRUCTIONS: FlexiBTS: If the faulty FSP is in the extension module, block/unblock the extension module, otherwise block/unblock the BTS. FlexiLiteBTS: 1. Block/unblock Flexi Lite BTS. 2. Replace the Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: Unit SW download failed : 6: EFaultId_SwDownloadAl : Software update to a unit/subunit or module has failed. UltraSite, MetroSite: The fault can also be caused by disconnected CIF bus cables. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: 1. Download the BTS SW again. 2. If the alarming unit is WSP, block/unblock the WSP.
DN99580892
Id:0900d805809d5c0d Confidential
65
7650 BASE STATION FAULTY
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
3. If the alarming unit is WAM or WPA, reset the BTS. 4. If that does not help, replace the alarming unit. FlexiBTS: 1. Download the BTS SW again. 2. FCM: Reset the BTS. 3. If Step 2 does not help, replace the alarming module. FlexiLiteBTS: 1. Download the BTS SW again. 2. Reset the BTS. 3. If Step 2 does not help, replace the Flexi Lite BTS.
FAULT NAME FAULT ID
: Unit initialization failure : 12: EFaultId_TcomConfigAl 13: EFaultId_AtmConfigAl 15: EFaultId_InitializationAl 4040: EFaultId_InitFaultManAl MEANING : A unit/module or an IP address initialization has failed. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: 1. Block/unblock the alarming unit. 2. Check if the non-commissioned WAM is the Master WAM. If so, this causes the fault. Check the fault history to find out why the WAM switch-over occurred. 3. If the WAM is the fault source, check the RNC IP address in the commissioning file and modify the file if needed. If that does not help, perform a power-off reset. 4. If step 3 does not help, replace the alarming unit. FlexiBTS: 1. Block/unblock the alarming module. If that does not help, replace the alarming module. 2. If the FCM/FCT is the fault source, check the RNC IP address in the commissioning file and modify the file if needed. If that does not help, perform a power-off reset. 3. If Step 2 does not help, replace the alarming module. FlexiLiteBTS: 1. Block/unblock the alarming module. If that does not help, replace the alarming module. 2. If the SCR is the fault source, check the RNC IP address in the commissioning file and modify the file if needed. If that does not help, perform a power-off reset. 3. If Step 2 does not help, replace the alarming module.
FAULT NAME FAULT ID MEANING
: Unit not supported by current BTS SW version : 95: EFaultId_NotSupportedUnit : An unsupported unit has been detected in the BTS. Typically, this happens when a new unit version is installed and there is older BTS SW in use that does not support the new unit version. INSTRUCTIONS: FlexiBTS, UltraSite/EUBB::
66
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
1. Upgrade the 2. Replace the FlexiLiteBTS: 1. Upgrade the 2. Replace the
7650 BASE STATION FAULTY
system module SW. unit. Flexi Lite BTS software. Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: Unit synchronization failed : 16: EFaultId_SynchronizationAl : UltraSite, MetroSite, MetroSite 50, Triple-mode: The WAM/WSPC synchronization has failed. FlexiBTS: FCM/FCT/FSP synchronization has failed. INSTRUCTIONS: 1. Block/unblock the alarming unit. 2. Replace the alarming unit. FlexiLiteBTS: 1. Block/unblock the Flexi Lite BTS. 2. Replace the Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: Unknown HW resource : 94: EFaultId_UnknownUnitType : A unit cannot be identified by its product code or by its physical device address (object ID). INSTRUCTIONS: FlexiBTS: Replace the alarming unit/module. FlexiLiteBTS: Replace the Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: Unknown product code : 93: EFaultId_UnknownProductCode : A module cannot be identified by its product code but is known by its physical device address (object_ID). INSTRUCTIONS: UltraSite/EUBB: Replace the alarming module. FlexiBTS: Replace the alarming module. FlexiLiteBTS: Replace the Flexi Lite BTS.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
FAULT NAME FAULT ID MEANING
DN99580892
Uplink data buffer synchronization failure 2033: EFaultId_Transu_UlDbSyncChAl The uplink data buffer loses synchronization. 1. If only one FSP in the BTS generates this alarm, the FSP is faulty. 2. If all FSPs generate this alarm, the FSM is faulty. 3. Block/unblock the FSM. 4. If that does not help, replace the faulty module (System Module).
: Validation of signed file failed : 4145: EFaultId_SignatureValidationFailedAl : SW file validation against its signature failed.
Id:0900d805809d5c0d Confidential
67
7650 BASE STATION FAULTY
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
INSTRUCTIONS: Trigger SW update for BTS to the requested SW version.
FAULT NAME FAULT ID MEANING
: WAM internal error : 300: EFaultId_AtmRmCommAl : The C-Plane Telecom SW does not communicate with the C-Plane TUPC SW because of a fault. INSTRUCTIONS: Replace the faulty unit
FAULT NAME FAULT ID
: WCI baseband reference clock failure : 1001: EFaultId_RedundantClkMss 1002: EFaultId_MasterClkMss MEANING : The master or redundant WSC does not generate Baseband Reference Clock (BRCLK) to the WCI because of an internal failure or a clock driver failure in the WSC unit. INSTRUCTIONS: 1. Block/unblock the active WSC unit. 2. Replace the WCI unit. 3. Replace both WSC units.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
WIB unit AC line break fault 1309: EFaultId_AcLineBreakAl There is a mains break. The BTS power supply is cut off. Check the power supply to the BTS.
FAULT NAME FAULT ID MEANING
: WSM failure : 3001: EFaultId_EubbWsmAl : The BTS has detected an abnormal operation or a failure in the internal functionality of the WSMF unit. INSTRUCTIONS: Note: Perform the steps below in the listed order until the alarm disappears. 1. Check the alarm history, alarming unit and subrack. 2. Check that the unit is properly connected. If the unit LED does not light up, the unit is faulty. 3. Reset the BTS. 4. Replace the alarming unit.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
WSMF WAM Interconnection Failure 4049: EFaultId_WsmfWamInterconnectionFailureAl Connection failure between WAMA and WSMF Check that cables are connected between WAMA-WSMF and
WSMF-AXCF.
FAULT NAME : WSP PCI-bus failure FAULT ID : 225: EFaultId_PCIInvalidDeviceAl
68
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7650 BASE STATION FAULTY
226: EFaultId_PCITargetNotFoundAl 227: EFaultId_PCITargetDSPAmountAl MEANING : There is a fault in the internal WSP/FSP PCI bus target (DSP) connections. Some of the WSP/FSP DSP processors may be broken and out of use. INSTRUCTIONS: Replace the alarming unit/module. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
DN99580892
Id:0900d805809d5c0d Confidential
69
7651 BASE STATION OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
29 7651 BASE STATION OPERATION DEGRADED Meaning A major fault (or faults) has occurred in the base station. Check the reason for the fault from the supplementary text field of the alarm. The effect of the fault on the functioning of the network element depends on the fault description. For more information, see base station fault descriptions in WCDMA RAN and Flexi Direct System Libraries. Supplementary information fields 1
rack (cabinet) number
2
shelf number
3
slot
4
type of unit
5
unit number
6
subunit number
7
feature code
For more information, see instructions on Alarm Structure. Instructions Verify the configuration of a BTS by checking the commissioning, cabling and correct installation of the units/modules at the BTS. Make sure the environment does not cause the fault. Before a unit/module is replaced at the BTS, the site should be reset to recover from any temporary faults which might have caused the malfunctioning of the unit/module. When an active alarm is a 'Start' alarm, a site reset is required to cancel the alarm. If the site reset or module block/unblock does not help, replace the faulty unit/module (see the source of the alarm and instructions fields of the corresponding alarms). Below is the list of BTS fault(s) which might have caused this alarm in BTS WN 8.0 release. In case of earlier SW release and in case you need more detailed fault
70
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7651 BASE STATION OPERATION DEGRADED
descriptions refer to WCDMA RAN and Flexi Direct System Libraries. The BTS fault descriptions are also included in BTS SW release documentation. If that does not help, contact your local Nokia Siemens Networks representative.
FAULT NAME
: 10b8b coding error in Optical Interface device FAULT ID : 2004: EFaultId_OIC_LVDSRecAl MEANING : The fiber cable has interference; the data becomes faulty. A physical connection failure between the optical interface and the summing function (caused by bad circuit joints, for example). INSTRUCTIONS: 1. Reset the RF Module behind the faulty optical interface by blocking/unblocking it. 2. If that does not clear the fault situation, replace the RF Module that is causing the alarm. 3. If the System Module is the only source causing the alarm, or replacing the RF Module does not clear the fault situation, replace the System Module that is causing the alarm.
FAULT NAME FAULT ID MEANING
: 2M external reference missing : 1899: EFaultId_2MExtRefMissAl : The reference clock monitoring has detected a loss of 2.048 MHz signal received from an external reference source, connected to the Sync In interface of the System Module. INSTRUCTIONS: Note! Perform the steps below in the listed order until the alarm disappears. 1. Check the cabling (connected to Sync In interface). 2. Check that the 2.048MHz reference source is working normally and the 2.048 MHz signal is available. 3. Replace the alarming module.FlexiLiteBTS: Replace the Flexi Lite BTS.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
FAULT NAME FAULT ID
DN99580892
ATM faulty 45: EFaultId_ATM_SFN_PollingTimeoutAl A WAM internal failure. 1. If ping to the BTS is working, restart the BTS remotely. 2. Ping the BTS. If it is not working but ping to the AXC is working, then restart the AXC remotely so that the BTS is also restarted automatically. 3. Ping the AXC. If it is not working, visit the site and restart the BTS. If this does not help, replace the alarming WAM unit.
: ATM processor faulty : 590: EFaultId_AtmMcuBrokenAl
Id:0900d805809d5c0d Confidential
71
7651 BASE STATION OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
594: EFaultId_SfnIrqFailureAl : UltraSite, MetroSite, MetroSite 50, Triple-mode: There is a fault in the WAM processor SFN interrupt or the SFN is not being updated in the WSPC MCU. There is a MCU failure in the WAM or the ATM loop test at start-up has failed. FlexiBTS: There is such a fault in the FSM that the SFN is not being updated in the FSP MCU. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode: 1. If ping to the BTS is working, restart the BTS remotely. 2. Ping the BTS. If it is not working but ping to the AXC is working, restart the AXC remotely so that the BTS is also automatically restarted. 3. Ping the AXC. If it is not working, visit the site and restart the BTS. If this does not help, replace the alarming WAM unit. FlexiBTS: 1. Reset the BTS. 2. If the BTS reset does not help, change the alarming module. MEANING
FAULT NAME FAULT ID MEANING
: ATM traffic overload : 304: EFaultId_TrafficCausedBufferOverflowAl : There is a buffer overflow caused by a traffic overload. The maximum capacity is exceeded and some data is discarded. INSTRUCTIONS: 1. Check that bandwidths (cells/s) are the same at the BTS, AXC and RNC. 2. Check the data integrity from the incoming Iub (see Troubleshooting instructions). 3. Check the other transmission elements' active faults (see the faults for AXC document).
FAULT NAME FAULT ID MEANING
: Active clock tuning fault : 1831: EFaultId_ActiveClkTuningAl : The phase measurement cannot be performed in the active WSC or WMC. INSTRUCTIONS: 1. Run fast tuning with BTS Site Manager. 2. Block/unblock the alarming unit. 3. Replace the alarming unit. Note that because of a fault situation in the active clock, the redundant clock is not tuned. To make sure that the tuning is correct, run "Fast Tune BTS Clock" with BTS Site Manager after the switchover when the new WSC is taken into use. If there is a WMC or only one WSC, the tuning continues but the cells remain disabled.
72
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7651 BASE STATION OPERATION DEGRADED
FAULT NAME FAULT ID MEANING
: Address mismatch in summing : 2019: EFaultId_Muksu_SsubMmAl : There is a baseband bus address mismatch in the summing. There are two possible causes: A configuration error (two different baseband units functioning) - after an acknowledgment the fault returns again. Data corruption on the bus - appears once when unsynchronized data is sent by the baseband. INSTRUCTIONS: Check the antenna mapping to the local cells in the commissioning file.
FAULT NAME FAULT ID MEANING
: Antenna link is down : 476: EFaultId_Rp3BusError : Antenna (RP3) link is down: transmitter or receiver drops from synchronization. INSTRUCTIONS: Note! Perform the steps below in the listed order until the fault disappears: FlexiBTS: 1. If the alarming module is the Extension System Module (FSM2), restart it. If the alarming module is the System Module (FSM1), restart the BTS. 2. If that does not help, replace the alarming FSM. FlexiLiteBTS: 1. Reset the BTS. 2. Replace the Flexi Lite BTS. UltraSite/EUBB: 1. If the alarming unit is WSPF, or if all WSPFs generate this alarm, restart the BTS. 2. If that does not help, replace the WSMF.
FAULT NAME FAULT ID MEANING
: BB bus message in the wrong slot : 2057: EFaultId_MuksuMsgInWrongSlotAl : Baseband bus message multiplexing slot for the message is not possible to be fulfilled. INSTRUCTIONS: 1. Check antenna mapping to the local cells in the commissioning file. 2. Check the cables between the System Module and RF Module. 3. Replace the alarming module.
FAULT NAME FAULT ID MEANING
: BB bus reception error : 2044: EFaultId_TransuSMTimeOffAl : The master frame in the received RF BB frame is not in the correct place related to the internally generated master frame pulse. Either the frame has been set into the wrong place (PI delay) or the data itself is in the wrong place. INSTRUCTIONS: 1. If only one FSP in the BTS generates this alarm, the FSP
DN99580892
Id:0900d805809d5c0d Confidential
73
7651 BASE STATION OPERATION DEGRADED
is 2. 3. 4.
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
faulty. If all FSPs generate this alarm, the FSM is faulty. Block/unblock the FSM. If that does not help, replace the faulty module (System
Module).
FAULT NAME FAULT ID MEANING
: BB bus reception error (summing device) : 2016: EFaultId_Muksu_SMTimeOffAl : The master frame in the received baseband bus frame is not in the correct place related to the internally generated master frame pulse. Either the frame has been set in the wrong place (PI delay), or the data itself is in the wrong place. INSTRUCTIONS: FlexiBTS: 1. Check the cables between the Master System Module and RF Module/Extension System Module. 2. Replace the unit causing the fault (Master System Module, Extension System Module, RF Module, FBIA). UltraSite/EUBB: 1. Replace the unit causing the fault (WSPF, WSMF).
FAULT NAME FAULT ID MEANING
: BB bus transmission error : 2017: EFaultId_Muksu_SRx10b8bAl : A decoding error has been detected in the baseband internal link. The data packet is lost or the content is corrupted. This situation is also triggered when the links do not synchronize with each other. INSTRUCTIONS: FlexiBTS: 1. Check the cables between the Master System Module and RF Module/Extension System Module. 2. Replace the alarming unit (System Module). UltraSite/EUBB: 1. Replace the alarming unit (WSMF).
FAULT NAME FAULT ID MEANING
: BOFU Post failed : 4021: EFaultId_BOFU_Post_failedAl : The unit or module has been tested during BTS power-on self test (POST) and a failure has been detected. INSTRUCTIONS: 1. Block/unblock the alarming unit/module. 2. Remove/reinsert the alarming unit/module. 3. Replace the alarming unit/module.
FAULT NAME FAULT ID
74
: BTS Master Clock tuning failure : 1818: EFaultId_Ov_OscAl
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7651 BASE STATION OPERATION DEGRADED
MEANING
: The OCXO adjustment area is reaching its limit value. The DAC word value of the OCXO is lower than 205 or greater than 3891 (5 of the total adjustment area). The range for the DAC word is 0 - 4095. INSTRUCTIONS: Note! Perform the steps below in the listed order until the fault disappears. 1. Check the other alarms of the BTS and FTM and act accordingly. 2. If there are no other synchronization related alarms active, start the fast tuning with BTS Site Manager. 3. Reset the site. Run fast tuning again. 4. Check the reference signal accuracy by measuring it with a frequency counter (note: requires a good timebase for the counter). The reference signal can be found from the Sync Out interface of the Flexi System Module, the required accuracy is +/-0.015ppm. If the reference accuracy is correct, run fast tuning. 5. If that does not help, replace the system module FlexiLiteBTS: replace the Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: BTS RNC/Flexi Direct RNC interface signalling link failure : 19: EFaultId_Aal2LinkAl : An AAL2 signaling link failure. The most common reason for this alarm is a frequently breaking transmission. In case of Ultra BTS, it can be caused by a broken WAM. INSTRUCTIONS: 1. Check the other transmission elements' active alarms (see the Alarms for AXC document). 2. Check the BTS and RNC transmission settings. 3. Reset the AXC. 4. Change the WAM unit. Note: The BTS and the AXC can be restarted remotely. FlexiBTS: 1. Reset the BTS. 2. Check the transmission links to the RNC. 3. Check the BTS and RNC transmission settings. 4. Replace the System Module
FAULT NAME FAULT ID MEANING
: BTS RNC/Flexi Direct RNC interface signalling link failure : 17: EFaultId_CnbapLinkAl : A common NBAP link failure. It can be caused by a transmission network problem. The most common reason for this alarm is a frequent transmission breaking. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: 1. Check the other transmission elements' active alarms (see the Alarms for AXC document). 2. Check the BTS and RNC transmission settings. 3. Reset the AXC. 4. Change the WAM unit.
DN99580892
Id:0900d805809d5c0d Confidential
75
7651 BASE STATION OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
Note! The BTS and the AXC can be restarted remotely. FlexiBTS: 1. Reset the BTS. 2. Check the transmission links to the RNC/Flexi Direct RNC. 3. Check the BTS and RNC/Flexi Direct RNC transmission settings. 4. Replace the System Module.
FAULT NAME FAULT ID MEANING
: BTS RNC/Flexi Direct RNC interface signalling link failure : 18: EFaultId_DnbapLinkAl : A dedicated Node-B Application Protocol (NBAP) link failure. It can be caused by the RNC. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: 1. Check the other transmission elements' active alarms (see the Alarms for AXC document). 2. Check the BTS and RNC transmission settings. 3. Reset the AXC. 4. Change the WAM unit. Note! The BTS and the AXC can be restarted remotely. FlexiBTS: 1. Reset the BTS. 2. Check the transmission links to the RNC. 3. Check the BTS and RNC transmission settings. 4. Replace the System Module.
FAULT NAME FAULT ID
: BTS SW download or activation failed : 29: EFaultId_FileCorruptionAl 30: EFaultId_SwUpdateAl MEANING : The SW update to the BTS has failed. The error can be caused by a unit reset during the SW update, a hardware problem in the unit or cabinet, or a corrupted flash file system. INSTRUCTIONS: FlexiBTS: 1. Retry the SW update. 2. If other flash memory-related faults are active for the alarming module at the same time, replace the alarming module. FlexiLiteBTS: 1. Retry the SW update. 2. If other flash memory-related faults are active for the Flexi Lite BTS at the same time, replace the Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
76
: BTS configuration not supported : 4097: EFaultId_BtsConfNotSupportedAl : FSP does not support requested BTS configuration.
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7651 BASE STATION OPERATION DEGRADED
INSTRUCTIONS: Note! Perform the steps below in the listed order until the fault disappears. 1. Change BTS configuration. 2. Reset BTS.
FAULT NAME FAULT ID
: BTS file error : 1802: EFaultId_FileRequestFlashAl 1803: EFaultId_FileParsingFailedAl 1866: EFaultId_RulesMissingAl 1867: EFaultId_RulesParsingAl MEANING : UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: The BTS unit properties data is invalid or missing. FlexiBTS: The BTS module properties data or optical interface FPGA file is invalid or missing. The FSP MCU SW file is invalid or missing. FlexiLiteBTS: The BTS properties data or optical interface FPGA file is invalid or missing. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: 1. Download two different SW packages so that the faulty file is removed from the BTS. 2. Download the SW again. 3. If the fault still exists after 10 minutes, replace the alarming unit. FlexiBTS, FlexiLiteBTS: 1. Download two different SW packages so that the faulty file is removed from the BTS. 2. Download the SW again. 3. Replace the System Module.
FAULT NAME : BTS file error FAULT ID : 136: EFaultId_TcomConfFileAl MEANING : Telecom configuration file(s) are invalid, missing, or not accessible. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: 1. Download two different SW packages so that the faulty file is removed from the BTS. 2. Download the SW again. 3. If the fault still exists after 10 minutes, replace the alarming unit. FlexiBTS: 1. Download two different SW packages so that the faulty file is removed from the BTS. 2. Download the SW again. 3. Replace the System Module or FBIA.
DN99580892
Id:0900d805809d5c0d Confidential
77
7651 BASE STATION OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
FAULT NAME FAULT ID MEANING
: BTS internal SW management problem : 3090: EFaultId_BtsInternalSwManagementProblem : A software update to a unit/module or subassembly has failed, or a corrupted SW file has been detected in the FLASH. INSTRUCTIONS: Note: Perform the steps below in the listed order. FlexiBTS: 1. Check other active BTS faults. If the ROM disk is corrupted, change the alarming module. 2. Reset the RF Module and/or FBIA and/or System Module, depending on the alarm source: a. Reset the RF Module by blocking/unblocking it. b. Reset the FBIA by blocking/unblocking it. c. Reset the System Module. 3. Update and activate the SW to the BTS. 4. Check the SW files. 5. Replace the alarming module/unit. UltraSite/EUBB: 1. Check other active BTS faults. If the ROM disk is corrupted, change the alarming unit. 2. Reset the alarming unit. 3. Update and activate the SW to the BTS. 4. Check the SW files. 5. Replace the alarming unit. FlexiLiteBTS: 1. Reset the and/or DSP and/or CC&T, depending on the alarm source. 2. Update and activate the SW to the BTS. 3. Check the SW files. 4. Replace the alarming Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
78
: BTS reference clock missing : 3080: EFaultId_BtsReferenceClockMissing : This BTS fault indication is generated if the reference clock monitoring function of the BTS does not receive the highest configured synchronization reference signal or if all the synchronization reference signals are missing. The BTS fault is not generated if the highest configured synchronization source is present, no matter what the lower level source statuses are. Background information: There is a fixed synchronization priority list in the FlexiBTS: -Priority 1: PPS (Pulse Per Second) signal connected to the Synchronization Input interface (Sync In) of the System Module. Normally the PPS signal is generated by the GPS receiver. -Priority 2: external 2.048MHz signal connected to the Sync
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7651 BASE STATION OPERATION DEGRADED
In interface. -Priority 3: the reference signal coming from the integrated transmission unit (FTM). Normally, all the FlexiBTS sources are not in use at the same time (it depends on the network planning and BTS configuration). During the BTS start-up, the available sources are checked against the reference source list in the BTS commissioning file and deviations regarding the missing highest priority source generate a fault. During runtime operation, the BTS fault functionality runs autonomously - notices also added/vanished sources which are missing from the commissioning file. The source for the FTM (which is the priority 3 source for the FlexiBTS) can be TDM interface signal (for example E1, T1...), physical layer Synchronous Ethernet (SyncE) signal or application layer Timing over Packet (ToP) in which the timing information to BTS(s) is generated by a ToP master. The FTM reference source priority selection is not fixed but user-selectable. Furthermore, if a signal listed in the FTM references is not received, a BASE STATION TRANSMISSION ALARM is reported. INSTRUCTIONS: Depending on the installed and commissioned synchronization source(s) listed in section "Meaning", see the commissioned synchronization option below and perform the steps in the listed order until the BTS fault indication disappears. GPS receiver (PPS source): 1. If there is a GPS receiver commissioned at the BTS site, note the following: If the GPS receiver is not locked to any satellite, it turns off the PPS signal which is normally delivered to the BTS (Sync In interface). The most common reason is that the GPS receiver does not see any satellites because of poor antenna installation (poor sky visibility). The only permanent cure for this is to change the GPS antenna location. One indication of a fairly poor sky visibility is that the BTS fault is activated/canceled every now and then. 2. There might be a malfunction in the GPS receiver. Perform a (remote) power reset for the GPS receiver. 3. There might be a malfunction in the BTS. Perform a BTS site reset. 4. The GPS cable and/or connectors might be damaged. Check the cable and the connectors. 5. There might be a HW fault in the GPS receiver. Check the operation and change the HW, if needed. External 2.048MHz signal: 1. If there is an external 2.048MHz signal source commissioned at the BTS site, check the BTS faults of that device and act accordingly. If this does not help, check the cables. Note that since the device type is not known, detailed instructions cannot be given. For further actions refer to the appropriate user manual of the device.
DN99580892
Id:0900d805809d5c0d Confidential
79
7651 BASE STATION OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
2. There might be a malfunction in the BTS. Perform a BTS site reset. FTM reference (TDM, SyncE or ToP as source): 1. If there is an integrated transmission unit (FTM) commissioned at the BTS site, note the following: the FTM unit operates so that if it is not locked to a synchronization source, it turns off the clock reference signal which is normally delivered to the BTS master clock. The synchronization source of the FTM (set by the FTM synchronization priority setting) might be missing, causing the FTM internal clock to drop to holdover mode. In this case, the fault in the transmission network must be corrected (FTM itself might be working fine). 2. Check the alarms of the FTM unit and act accordingly. 3. Check the synchronization settings of the FTM unit. 4. There might be a malfunction in the BTS. Perform a BTS site reset. 5. There might be an equipment failure in the FTM unit. Check the operation and replace the unit, if needed. Note: Normally the reason is not an equipment failure, but there might be connection failures in the transmission or packet network, causing the FTM clock to drop to holdover mode. Especially the BTS fault indication activity (frequent BTS fault indication activations/cancels instead of a stable BTS fault indication state) points to the transmission network instability, not to a failure in the unit. If the previous steps do not help, there might be an equipment failure in the System Module. Check the operation and if resetting the BTS site does not help, replace the System Module.
FAULT NAME FAULT ID MEANING
: Baseband Bus failure : 3020: EFaultId_BaseBandBusFailure : The BTS has detected an abnormal operation or a failure in the BTS internal baseband
bus. The failure cannot be pointed to a specific unit/module but there are several possible fault sources. INSTRUCTIONS: Note: Perform the steps below in the listed order. FlexiBTS: 1. Check other active BTS alarms and act accordingly. 2. Check the cables between the System Module and RF Module/Extension System Module. 3. Reset the RF Module and/or System Module, depending on the alarm source: a. Reset the RF Module by blocking/unblocking it. b. Reset the Extension System Module by blocking/unblocking it. c. Reset the master System Module.
80
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7651 BASE STATION OPERATION DEGRADED
4. Replace the alarming RF Module/Extension System Module. 5. If the master System Module is the source or replacing the RF Module/Extension System Module does not clear the fault situation, replace the alarming master System Module. UltraSite/EUBB: 1. Check other active BTS alarms and act accordingly. 2. Reset the alarming unit. 3. Check the cables in backplane. 4. Replace the alarming unit. FlexiLiteBTS: 1. Check other active BTS faults and act accordingly. 2. Reset the BTS by blocking/unblocking it. 3. Replace the Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: Baseband bus configuration of was rejected : 1811: EFaultId_BbBus_ConfFailedAl : The baseband bus related configuration of was rejected by the HW, SW, DSP, or LTX. INSTRUCTIONS: Replace the alarming module. FlexiLiteBTS: Note! Perform the steps below in the listed order until the fault disappears: 1. Restart the BTS 2. Replace the FlexiLiteBTS unit
FAULT NAME FAULT ID MEANING
: Baseband internal link test failed : 4053: EFaultId_SrioChainTestFailureAl : Echo test of Baseband (SRIO) link between FSP boards was not successful. INSTRUCTIONS: 1. Manually reset the BTS. 2. If alarm is still visible after BTS reset, replace the alarming FSM module.
FAULT NAME FAULT ID MEANING
: Boot configuration inconsistency detected : 4102: EFaultId_BootConfigurationInconsistencyAl : During SW update it has been detected that configurations of active and passive SW in HW unit are the same. Active and passive SW configurations are compared: - before SW download, - during SW activation, before active and passive SW switch, - during start-up. INSTRUCTIONS: Replace the faulty unit.
FAULT NAME FAULT ID MEANING
DN99580892
: Cabinet door open : 1300: EFaultId_DoorAl0 : The cabinet door is open or the cabinet door sensor is
Id:0900d805809d5c0d Confidential
81
7651 BASE STATION OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
faulty. INSTRUCTIONS: 1. Ensure that the cabinet doors are properly closed. 2. Check that the door switches function correctly and that they have been adjusted correctly. Note: this alarm can be enabled or disabled in commissioning.
FAULT NAME FAULT ID MEANING
: Commissioning error: : 3060: EFaultId_CommissioningError : Some of the commissioning parameters are either missing or faulty. Or there is a mismatch between them. INSTRUCTIONS: Note: Perform the steps below in the listed order. 1. Check the commissioning parameters with the BTS Site Manager Commissioning Wizard. 2. Load the correct commissioning file to the BTS.
FAULT NAME FAULT ID MEANING
: Communication failure : 1806: EFaultId_CommunicationFailureAl : Communication with the application failed. The application has not replied to the message that has been sent/resent to it. INSTRUCTIONS: FlexiBTS: 1. Make sure that the unit/module is properly connected. If the unit/module LED does not light up, the unit/module is faulty. Check the alarming unit/module. 2. Check the fault history. FlexiLiteBTS: 1. If the Flexi Lite BTS LED does not light up, the BTS is faulty. Check the Flexi Lite BTS. 2. Check the fault history.
FAULT NAME FAULT ID MEANING
: Communication failure : 458: EFaultId_VcpError : An internal communication fault in the decoding process in the module, for example, a decode co-processor error. INSTRUCTIONS: 1. Reset the alarming unit/module. 2. Replace the alarming unit/module.
FAULT NAME FAULT ID
: Communication failure inside WSP : 414: EFaultId_McbspMessagePoolExhausted 446: EFaultId_McbspSwsError MEANING : An internal communication failure between the DSP processors. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode: 1. Block the alarming WSP. 2. The fault might be in the WTR or WPA (see Troubleshooting instructions).
82
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7651 BASE STATION OPERATION DEGRADED
Otherwise, check for other alarms. If the " autonomous reset as recovery action" alarm has occurred for the alarming WSP, replace the alarming WSP unit. FlexiBTS: 1. If only one FSP in BTS generates this alarm, the FSP is faulty. 2. If all FSPs generate this alarm, the FSM is faulty. 3. Block/unblock the FSM. 4. If that does not help, replace the faulty module (System Module). UltraSite/EUBB: 1. If only one WSPF in the BTS generates this alarm, the WSPF is faulty. 2. If all WSPFs generate this alarm, the BTS is faulty. 3. Block/unblock the BTS. 4. If that does not help, replace the faulty module.
FAULT NAME FAULT ID MEANING
: Configuration error: : 3070: EFaultId_ConfigurationError : There is an incompatibility problem in the BTS HW/SW versions or the HW/HW configuration. Another possibility is that there is a mismatch between the BTS configuration and the RNC/Flexi Direct RNC parameters. INSTRUCTIONS: Note: Perform the steps below in the listed order. 1. Check the installed HW/SW version compatibility and the HW compatibility with the current BTS configuration. 2. Check that the BTS cell parameters from the RNC/Flexi Direct RNC match the BTS HW configuration (for example frequency, power). 3. Check the RNC/Flexi Direct RNC BTS faults for the alarming local cell (LCR). 4. Recommission the BTS to ensure that all parameters are correctly configured.
FAULT NAME FAULT ID MEANING
: Connection to ToP master missing : 4058: EFaultId_TopRefClkMissingAl : The reference clock monitoring has detected a loss of ToP reference clock signal received from the master clock. INSTRUCTIONS: Note! Perform the steps below in the listed order until the fault disappears. 1. Check Ethernet interface functionality used by Timing Over Packet. Check if other faults related to the Ethernet interface exist. 2. Check Timing Over Packet configuration: the Master clock IP address is configured properly and the Master clock supports the given parameters. 3. Check the Master clock functionality. 4. Check that the IP connection between the Master clock and BTS is working.
DN99580892
Id:0900d805809d5c0d Confidential
83
7651 BASE STATION OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
FAULT NAME FAULT ID MEANING
: Connection to transmission broken : 1829: EFaultId_ConnToTransBrokenAl : UltraSite, MetroSite, MetroSite 50, Triple-mode: The AXC is missing, data or states are corrupted in the ATM, or there are possible hardware or transmission related failures. FlexiBTS: Data or states are corrupted in the ATM, or there are possible hardware or transmission related failures. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode: 1. Check the transmission connections. 2. If the transmission type is the AXC, reset the WAM. 3. If that does not help, replace the alarming unit. FlexiBTS: 1. Check the transmission connections. 2. Reset the site. 3. If that does not help, replace the alarming System Module.
FAULT NAME FAULT ID MEANING
: DSC-bus failure : 208: EFaultId_DscNodeBlockedAl : There is a failure in the bus between the WAM and WSP (DSC-bus), which means that messages do not get through via that DSC-bus. INSTRUCTIONS: 1. Block/unblock the alarming unit. 2. Replace the alarming unit.
FAULT NAME FAULT ID MEANING
: DSC-bus failure : 597: EFaultId_DscFaultAl : There are communication problems between the WAM and WSP. This alarm may occur if the WSP is hot removed or the WSP crashes. INSTRUCTIONS: If the failure still exists after the site reset, replace the WAM unit.
FAULT NAME FAULT ID MEANING
: DSP accelerator initialization failure : 2302: EFaultId_RsaInitializationError : There is a signal processing (DSP) related malfunction in the BTS. This might affect the signal processor receiver functionality processed by the alarming unit/module. INSTRUCTIONS: FlexiBTS: 1. If the alarming module is the Extension System Module (FSM2), restart it. If the alarming module is the System Module (FSM1),
84
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7651 BASE STATION OPERATION DEGRADED
restart the BTS. 2. If that does not help, replace the alarming FSM or unit. UltraSite/EUBB: 1. If the alarming unit is WSPF, restart it. If all WSPFs generate this alarm, restart the BTS. 2. If that does not help, replace the alarming unit. Restart can be done by BTS block/unblock, system module block/unblock from BTS SEM and from NetAct to reset BTS.
FAULT NAME FAULT ID MEANING
: DSP failure in radiolink creation : 129: EFaultId_DspHoldAl : Radio link creation has been failing repeatedly because of DSP rejection. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode: 1. Block/unblock the alarming unit. 2. Replace the alarming unit. UltraSite/EUBB: 1. Block/unblock the EUBB subrack. 2. Replace the alarming unit. FlexiBTS: If the faulty FSP is in the extension module, block/unblock the extension module, otherwise block/unblock the BTS.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
DSP mode change failed 139: EFaultId_DspModeChangeFailAl DSP configuration to correct mode was not successful. Replace the alarming module/unit.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
DSP overheated 4101: EFaultId_DspOverheatingAl DSP overheating was detected during DSP initialization. 1. Check the fans and ensure that the ambient temperature on the site is acceptable. 2. If that does not help, replace the alarming FSP module.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
Downlink data buffer synchronization failure 2031: EFaultId_Transu_DlDbSynchChAl The downlink data buffer has lost synchronization. 1. If only one FSP in the BTS generates this alarm, the FSP is faulty. 2. If all FSPs generate this alarm, the FSM is faulty. 3. Block/unblock the FSM. 4. If that does not help, replace the faulty module (System Module).
DN99580892
Id:0900d805809d5c0d Confidential
85
7651 BASE STATION OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
FAULT NAME FAULT ID MEANING
: Error in commissioning data : 31: EFaultId_CommDataAl : The WTR initialisation parameters are faulty. The error can be caused by a missing parameter in the commissioning file: the cabling information (main, diversity), feeder loss, local cell resources, for example. INSTRUCTIONS: 1. Check that the cell parameters, RX cabling, feeder loss and MHA gain are correct in the commissioning file. 2. Update the information if needed. Reconfiguration commissioning is required for correcting the values.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
FSP in resetting state 4068: EFaultId_FspResetAl FSP is undergoing a cold reset. Note! Perform the steps below in the listed order until the fault disappears: FlexiBTS: 1. Reset the BTS. 2. Replace the faulty module/unit. FlexiLiteBTS: 1. Reset the BTS. 2. Replace the Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: FSP overheating : 4077: EFaultId_FspOverheatingAl : Temperature on the FSP board exceeds the critical threshold value. INSTRUCTIONS: 1. Check the fans and ensure that the ambient temperature on the site is acceptable. 2. If that does not help, replace the alarming module.
FAULT NAME FAULT ID MEANING
: FSP reset failure : 4100: EFaultId_FspResetFailureAl : FSMr2 FSP reset during BB reset recovery failed. FSMr3 FSP warm reset recovery failed. INSTRUCTIONS: Check the faulty FSP.
FAULT NAME FAULT ID MEANING
: Failure in AXU initialization : 14: EFaultId_AxuConfigAl : The BTS has lost connection to the AXU or the AXU SW is incompatible. The AXU does not respond to requests from the BTS. INSTRUCTIONS: 1. Check the AXC configuration. 2. Restart the AXC remotely. This will also cause a BTS restart.
86
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7651 BASE STATION OPERATION DEGRADED
FAULT NAME FAULT ID MEANING
: Failure in optical RP3 interface : 3030: EFaultId_FailureInOptical_Rp3Interface : The BTS has detected an abnormal operation or a failure in an optical RP3 interface between two modules. The failure cannot be pointed to a specific module but there are several possible fault sources. INSTRUCTIONS: Note: Perform the steps below in the listed order until the alarm disappears. 1. Check the other active BTS alarms and act accordingly. 2. Check the cables between the System Module and RF Module/Extension System Module. Note that dirty optical connectors may cause the signal level to drop too low. 3. Depending on the alarm source, reset the RF Module, Extension System Module and/or System Module by blocking/unblocking it. 4. Replace the alarming module's Small Form Factor Pluggable (SFP). Check also the SFP in the other end and replace it, if needed. 5. Replace the alarming RF Module/Extension System Module. 6. If the System Module is the only alarming source or replacing the RF Module/Extension System Module does not clear the fault situation, replace the alarming System Module.
FAULT NAME FAULT ID MEANING
: Failure in replaceable baseband unit : 3003: EFaultId_FbiaFailureAl : The BTS has detected an abnormal operation or a failure in the BTS replaceable baseband unit. INSTRUCTIONS: Note: Perform the steps below in the listed order until the BTS fault indication disappears. 1. Check the other active BTS faults and act accordingly. 2. Check if the plug-in type baseband unit is installed correctly. 3. Reset the alarming baseband unit. 4. Replace the alarming baseband unit.
FAULT NAME FAULT ID MEANING
: Fatal OSE Error : 418: EFaultId_OseFatalErr : The operating system (OSE) goes into the error handler with a fatal status. The cause can be, for example, out of memory situation. If only one FSP in BTS generates this fault, there is a malfunction in one of the FSP submodules. If all FSPs generate this fault, there is a malfunction in the FSM. INSTRUCTIONS: FlexiBTS:
DN99580892
Id:0900d805809d5c0d Confidential
87
7651 BASE STATION OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
Note! Perform the steps below in the listed order until the fault disappears. 1. Reset the System Module. 2. Replace the System Module. FlexiLiteBTS: Note! Perform the steps below in the listed order until the fault disappears. 1. Reset the FlexiLiteBTS 2. Replace the FlexiLiteBTS UltraSite/EUBB: 1. If only one WSPF in BTS generates this fault, the WSPF is faulty. 2. If all WSPFs generate this fault, BTS is faulty. 3. Block/unblock BTS. 4. If that does not help, replace the faulty module.
FAULT NAME FAULT ID
: Fault between WAM and WSP SFN (WSP) : 412: EFaultId_LostFrameSync 428: EFaultId_SystemFrameNumberParity MEANING : UltraSite, MetroSite, MetroSite 50, Triple-mode: Synchronization between the WAM and WSP is lost. FlexiBTS: Synchronization between the FCM and FSP/FBIA is lost. UltraSite/EUBB: Synchronization between the WAMF and WSPF is lost. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode: 1. If only one WSP in the cabinet generates this alarm, the WSP is faulty. 2. If all WSPs in a subrack generate this alarm, the WAM is faulty. 3. If all WSPs generate this alarm, the WSC/WMC is faulty. Otherwise, check for other alarms. If the " autonomous reset as a recovery action" alarm has occurred for the faulty WSP, replace the faulty WSP unit. FlexiBTS: 1. If only one FSP/FBIA in the BTS generates this alarm, the FSP/FBIA is faulty. 2. If all FSPs generate this alarm, the FSM is faulty. 3. Block/unblock the FSM. 4. If that does not help, replace the faulty module (System Module) or faulty FBIA. UltraSite/EUBB: 1. If only one WSPF in the BTS generates this alarm, the WSPF is faulty. 2. If all WSPFs generate this alarm, the BTS is faulty. 3. Block/unblock the BTS. 4. If that does not help, replace the faulty module.
FAULT NAME
88
: Fault in ATM interface
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7651 BASE STATION OPERATION DEGRADED
FAULT ID : 309: EFaultId_AtMuxAl MEANING : The WAM ATM interface is not responding correctly. INSTRUCTIONS: 1. Block/unblock the alarming unit. This resets the BTS. 2. If that does not help, replace the alarming unit.
FAULT NAME FAULT ID
: Fault in ATM interface : 591: EFaultId_SarChipBrokenAl 592: EFaultId_UxAsicAl 593: EFaultId_AtmHostBrokenAl MEANING : WAM ATM interface, AXC or CIF bus failure. The AXC may have been reset. WAM processor failure. INSTRUCTIONS: 1. Block/unblock the alarming unit. This will reset the BTS. 2. Swap the WAM units between subracks and check if the alarm follows the unit. Replace the alarming WAM unit. 3. Check the AXU. 4. Check the backplane connection between the WAM and AXU.
FAULT NAME FAULT ID
: Fault in O&M and DSP SW interface : 42: EFaultId_ WSPC_PPC_SFN_PollingTimeoutAl 43: EFaultId_DSP_PollingTimeoutAl MEANING : UltraSite, MetroSite, MetroSite 50, Triple-mode: Communication failure between the WAM and DSP. FlexiBTS: Communication failure between the FCM and FSP/FBIA. UltraSite/EUBB: Communication failure between the WSMF and WSPF. FlexiLiteBTS: Communication failure between the SCR and FSP. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode: 1. Block/unblock the alarming unit. 2. Replace the alarming unit. UltraSite/EUBB: 1. Block/unblock the EUBB subrack. 2. Replace the alarming unit. FlexiBTS: 1. Block/unblock the alarming module. 2. Replace the system module/plug-in FSP. FlexiLiteBTS: 1. Block/unblock Flexi Lite BTS. 2. Replace the Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
DN99580892
: Faulty configuration of system modules : 1858: EFaultId_FaultyFcmConfigurationAl : 1) There might be a faulty configuration with the Radio Modules connected to both the master system module and intended extension system module.
Id:0900d805809d5c0d Confidential
89
7651 BASE STATION OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
2) O&M master system module cannot be determined automatically. INSTRUCTIONS: 1) Remove Radio Modules from the intended extension system module and hot insert them to the intended master system module. 2) Connect IUB connection or LMT connection to system module that is intended to be O&M master.
FAULT NAME FAULT ID
: Flash operation failure : 214: EFaultId_FlashWrAl 215: EFaultId_FlashRdAl 216: EFaultId_FlashEraseAl 217: EFaultId_FlashDrvAl 218: EFaultId_FlashDbChksumAl MEANING : A flash memory operation failure. If this fault continuously appears, the flash chip may be broken. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: 1. Check the other active faults. If the /rom-disk is corrupted, change the alarming unit. 2. Block/unblock the alarming unit. There are no recovery actions and because of that the block/unblock can be attempted once. If that does not help, replace the alarming unit. FlexiBTS, FlexiLiteBTS: 1. Check the other active faults. If the /rom-disk is corrupted, change the alarming unit/module. 2. Block/unblock the alarming unit/module. There are no recovery actions and blocking/unblocking can be attempted once. If that does not help, replace the alarming unit/module.
FAULT NAME FAULT ID MEANING
: Frame burst receiving fault : 2013: EFaultId_OIC_Rp1CrcAl : The optical interface has detected a CRC error in the received synchronization burst from the clock function. This fault appears on the RX side. INSTRUCTIONS: 1. Depending on the alarm source, reset the RF Module and/or Extension System Module by blocking/unblocking it. 2. If that does not clear the fault situation, replace the RF Module/Extension System Module that causes the alarm. 3. If the System Module is the only alarming source, or replacing the RF Module/Extension System Module does not clear the fault situation, replace the System Module causing the alarm.
FAULT NAME FAULT ID
90
: Frame clock deviation fault : 2014: EFaultId_Muksu_SFCRCompDevAl
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7651 BASE STATION OPERATION DEGRADED
MEANING
: Synchronization to the clock control unit frame pulse has been achieved earlier but it differs from the currently received frame pulse. The internally generated frame clock might have drifted. INSTRUCTIONS: FlexiBTS: 1. Check the cables between the System Module and RF Module/Extension System Module. 2. Reset the alarming System Module. 3. Replace the alarming System Module. UltraSite/EUBB: 1. Reset the alarming WSMF. 2. Replace the alarming WSMF.
FAULT NAME FAULT ID MEANING
: Frame number synchronization error in optical interface : 2047: EFaultId_OIC_FrSyncLostAl : The timing of the new RP1 synchronization burst deviates from the present RP1 timing maintained in the BTS. INSTRUCTIONS: 1. Reset the System Module causing the alarm. 2. If resetting of the module does not help, replace the System Module causing the alarm.
FAULT NAME FAULT ID MEANING been inserted
: Incompatible SW version detected : 23: EFaultId_IncompatibleSwVersionAl 24: EFaultId_ObsoleteSwVersionAl : A new unit with incompatible SW has probably
in the BTS. INSTRUCTIONS: Update compatible SW to the BTS (check the SW versions to see the active SW version, and update the active SW version), unless it is automatically updated by NetAct. NOTE: If also fault 10:EFaultId_NoConnectionToUnitAl is active on the source unit then SW update should be postponed until fault 10:EFaultId_NoConnectionToUnitAl is cancelled. Related BTS - AXC interface: check the SW version of the BTS and AXC, and update compatible SW to the AXC or BTS.
FAULT NAME FAULT ID
: Incompatible unit detected : 83: EFaultId_WtraWsmaWspaNotSupportedInCabinetAl 91: EFaultId_WrongUnitTypeInCabinetAl MEANING : An unsupported unit (for example a WSMA, WTRA, WSPA, WMCM or WTRB) has been detected in the cabinet. INSTRUCTIONS: Replace the unsupported unit with a unit of the correct type.
FAULT NAME
DN99580892
: Incomplete network parameters received from AXU
Id:0900d805809d5c0d Confidential
91
7651 BASE STATION OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
FAULT ID MEANING
: 1851: EFaultId_CommDataNetworkParamAl : Mandatory DCN and/or ATM parameters are only partially received from the AXU to a WAM unit. INSTRUCTIONS: Check the parameters entered to the AXC and correct, if necessary.
FAULT NAME FAULT ID MEANING
: Internal MTU configuration failure : 4025: EFaultId_MtuConfigurationFailureAl : Internal Maximum Transfer Unit (MTU) configuration failed on FCM or FSP/FBIA. INSTRUCTIONS: 1. Reset the alarming System Module or unit. 2. Replace the alarming System Module or unit
FAULT NAME FAULT ID MEANING
: Internal communication error : 4087: EFaultId_InternalCommunicationErrorAl : Reliable message delivery service is not able to deliver an internal message to a recipient (FSP or FSM), and sends an asynchronous notification to the message sender about the unreachable recipient. INSTRUCTIONS: 1. Make sure that the unit/module is properly connected. 2. Reset the alarming unit. 3. Replace the alarming unit.
FAULT NAME FAULT ID MEANING
: Licence missing , : 1885: EFaultId_MissingLicense Al : The BTS detected a resource requiring a license but no license exists or is available. INSTRUCTIONS: Activate the appropriate license or increase the license amount.
FAULT NAME FAULT ID MEANING
: License missing , : 1833: EFaultId_LicenceMissingAl : The BTS detected a resource needing a license. However, no license exists or is free. INSTRUCTIONS: An appropriate license should be provided to BTS.
FAULT NAME FAULT ID MEANING
: Mains power break, running Battery Backup : 37: EFaultId_MainsBreakAl : There is a fault in the mains power supply. The BTS has received a Battery Backup alarm and the Intelligent Shutdown procedure has started. INSTRUCTIONS: Check the mains power supply.
FAULT NAME FAULT ID
92
: Master unit has lost connection to the slave unit : 4019: EFaultId_KeepAliveStatusErrorAl
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7651 BASE STATION OPERATION DEGRADED
MEANING
: Connection to the DSP submodule has been lost or the submodule reports an error situation. INSTRUCTIONS: Note! Perform the steps below in the listed order until the fault disappears: FlexiBTS: 1. Reset the BTS. 2. Replace the faulty module/unit. FlexiLiteBTS: 1. Reset the BTS. 2. Replace the Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: Message routing problem in receiver (RX) : 2058: EFaultId_MuksuMsgRoutingFailedAl : If a message does not get routed an interrupt is generated. Considered normal when Faradays are starting up and RP3 sync done. INSTRUCTIONS: If RF is the source: 1. Check antenna mapping to the local cells in the commissioning file. 2. Check the cables between the System Module and RF Module. 3. Replace the alarming module. If FSP is the source: Baseband reset should be performed.
FAULT NAME FAULT ID MEANING
: Missing NBAP cell parameters, defaults are used : 88: EFaultId_CommDataCellParam : One or more cell parameters are missing from the RNC/Flexi Direct RNC configuration data and the BTS commissioning file. INSTRUCTIONS: 1. Check the cell parameters in RNC/Flexi Direct RNC and BTS. 2. If the parameters configured to the RNC/Flexi Direct RNC are correct, lock and unlock all cells of this BTS using OMS Element Manager to trigger parameter sending from RNC to BTS again. 3. If the parameters configured to the RNC/Flexi Direct RNC are incorrect, lock the cells and configure the parameters to correct values. After that, unlock the cells. 4. If the default values for the cell parameters (such as rampdown time/step) are not appropriate in BTS, reconfigure the BTS with Commissioning Wizard.
FAULT NAME FAULT ID MEANING
: Module dangerously overheating : 4071: EFaultId_SysDangerouslyOverheatAl : Highest validated temperature value on FSP board exceeds the threshold value. INSTRUCTIONS: Note! Perform the steps below in the listed order.
DN99580892
Id:0900d805809d5c0d Confidential
93
7651 BASE STATION OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
1. Check the fans and ensure that the ambient temperature on the site is acceptable. 2. If that does not help, replace the alarming module.
FAULT NAME FAULT ID
: No connection to unit : 10: EFaultId_NoConnectionToUnitAl 4052: EFaultId_ConnectionToUnitLostAl MEANING : Connection to a unit that belongs to the BTS configuration has been lost or FSP cannot be detected. INSTRUCTIONS: FlexiBTS: 1. Make sure that the module is properly connected. If the module LED does not light up, the module is faulty. Check the alarming module. In case of two FSM-r3, check also SRIO cable connection between the system modules. 2. Check the fault history. FlexiLiteBTS: Check the fault history. UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: 1. Check the fault history, alarming unit and subrack. 2. If the SW has been updated recently, reload the SW. 3. If the WAF or WIC is alarming, try recommissioning the site. 4. Make sure that the unit is properly connected. If the unit LED does not light up, the unit is faulty. The fault might also be in the WPS unit or backplane. 5. Check the power cables, connectors, and the I2C bus cables. Cancel alarms: Removing and inserting the WIC, WSM or primary WAM causes a site reset. If both WSCs are removed, inserting the first removed WSC back into the cabinet causes a site reset. If the 7650 BASE STATION FAULTY alarm is issued, reset the site. First, try to reset the site with the software. If that does not help, replace the alarming unit. If the WSMF unit is not present (replaced by WSMB)in BTS, alarming WSPFs are not used and should be removed from BTS. WSPFs can be removed, because without a WSMF unit BTS works as UltraSite not as EUBB.
FAULT NAME FAULT ID
MEANING
94
: No connection to unit : 75: EFaultId_WSP_memory_concistency_err1 76: EFaultId_WSP_memory_concistency_err2 77: EFaultId_WSP_memory_concistency_err3 78: EFaultId_WSP_memory_concistency_err4 79: EFaultId_WSP_memory_concistency_err5 80: EFaultId_WSP_memory_concistency_err6 81: EFaultId_WSP_memory_concistency_err7 : The connection to a unit belonging to the BTS configuration
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7651 BASE STATION OPERATION DEGRADED
has been lost. INSTRUCTIONS: 1. Check the alarm history, alarming unit and subrack. 2. If SW updates have been done recently, reload the SW. 3. If the WAF or WIC is alarming, try recommissioning the site. 4. Check that the unit is properly connected. If the unit led does not light up, the unit is faulty. The fault may also be in the WPS unit or backplane. 5. Check the power cables and connectors as well as the I2C bus cables. Cancel alarms: Removing and inserting the WIC, WSM or primary WAM causes a site reset. If both WSCs are removed, inserting the first removed WSC back into the cabinet causes a site reset. If the 7650 BASE STATION FAULTY alarm is issued, reset the site. First try to reset the site by the software. If that does not help, replace the alarming unit.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
Not able to synchronize baseband bus with 1815: EFaultId_BbBus_SyncFailedAl The baseband bus synchronization towards failed. FlexiLite: Replace the alarming module/plug-in FSP. FlexiLiteBTS: Replace the Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: Not enough DSP resources per cell : 1861: EFaultId_NotEnoughFspResourcesPerCellAl : The number of DSP units in the BTS is too small. For every three cells, there must be at least one DSP present. INSTRUCTIONS: Increase the number of DSP units in the BTS.
FAULT NAME FAULT ID MEANING
: Not enough WSP resources per cell : 60: EFaultId_NotEnoughWspResourcesPerCellAl : The number of WSP units in the BTS is too small. For every three cells, there must be at least one WSP present. INSTRUCTIONS: 1. Check the possible WSP, WSM and WAM alarms. If baseband pooling is in use, check the LCG (Local Cell Group) commissioning. Check that all subracks are in working state. 2. Increase the number of WSP units in the BTS.
FAULT NAME FAULT ID MEANING
DN99580892
: Optical Interface Frame clock faulty : 2003: EFaultId_OIC_CleanerLockAl : The VCXO does not get correct control voltage from the PLL
Id:0900d805809d5c0d Confidential
95
7651 BASE STATION OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
filter of the clock cleaner. This may happen because of an unsuccessful clock recovery in the optical interface because of a missing or degraded input signal. INSTRUCTIONS: 1. Block/unblock the System Module. 2. Replace the System Module.
FAULT NAME FAULT ID MEANING
: Optical interface buffer alarm : 2051: EFaultId_Muksu_BufferAl : RP3 or Ethernet buffering is not working and the buffer becomes full. The optical device malfunctions. The fault may be generated because of synchronization problems or incorrect initialization. INSTRUCTIONS: 1. Depending on the interface, reset the connected module/unit behind the interface that causes the alarm by blocking/unblocking it. 2. If that does not clear the fault situation, replace the connected module/unit behind the interface causing the alarm. FlexiBTS: 3. If the System Module is the only alarm source, or replacing the RF Module/Extension System Module does not clear the fault situation, replace the System Module causing the alarm. UltraSite/EUBB: 3. If WSMF is the only alarm source, or replacing the connected module/unit does not clear the fault situation, replace the WSMF that causes the alarm.
FAULT NAME FAULT ID
: Optical interface data/control/Ethernet buffer full : 2006: EFaultId_OIC_DBRxFullAl 2007: EFaultId_OIC_DBTxFullAl 2008: EFaultId_OIC_CBRxFullAl 2009: EFaultId_OIC_CBTxFullAl 2010: EFaultId_OIC_EBFullAl MEANING : The RP3 or Ethernet buffering is not working and the buffer becomes full. The optical device is malfunctioning. The fault might be generated because of synchronization problems or incorrect initialization. INSTRUCTIONS: Swap the alarming and working links. Then check where the alarm is reported. If the alarming link remains the same, replace the System Module. If the alarming link changes, replace the RF Module behind that link.
FAULT NAME FAULT ID MEANING
96
: Optical interface faulty : 2000: EFaultId_OIC_TxAl 2001: EFaultId_OIC_PresAl : The Small Form Factor Pluggable (SFP) malfunction has occured or the SFP module is not physically present (no
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7651 BASE STATION OPERATION DEGRADED
electrical connection exists). The SFP is a part of the fibre cable package. INSTRUCTIONS: 1. Check that the SFP is properly connected. 2. Replace the SFP module.
FAULT NAME FAULT ID MEANING
: Out Of Frame Data Error : 420: EFaultId_OutOfData : An out of frame data error interrupt received from the SWS ASIC. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode: 1. The WSP is not necessarily faulty. Check also the state of the other units. 2. Block/unblock the WSP. 3. If that does not help, replace the faulty unit. FlexiBTS: 1. The FSPA is not necessarily faulty. Check also the state of the other units. 2. Block/unblock the FSM. 3. If that does not help, replace the faulty module (System Module).
FAULT NAME FAULT ID
: Oven oscillator heating failure : 901: EFaultId_OcxoHeatingAl 912: EFaultId_DualWscOvAMss MEANING : The heating of oven oscillator fails and the unit is broken. The ambient temperature can also be too low or change too fast. INSTRUCTIONS: 1. Check the active fan alarms. 2. Replace the clock unit.
FAULT NAME FAULT ID MEANING
: Oven oscillator missing pulse : 1820: EFaultId_OcxoPulseMissingAl : The output signal of the OXCO has some problems and one or more clock pulses are missed. INSTRUCTIONS: 1. Block/unblock the System Module. 2. Replace the System Module.
FAULT NAME FAULT ID MEANING
: Overload collision in transmitter : 2061: EFaultId_MuksuOverloadCollisionAl : Transmitter detected more data coming from a summing than the current link rate can support. INSTRUCTIONS: 1. Check antenna mapping to the local cells in the commissioning file. 2. Replace the alarming module.
FAULT NAME
DN99580892
: PLL status not locked
Id:0900d805809d5c0d Confidential
97
7651 BASE STATION OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
FAULT ID MEANING
: 4010: EFaultId_PLLStatusNotLockedAl : BTS monitors the FSP/FBIA/WSPF/WSMF PLL (Phase-Locked Loop) lock status and PLL locking fails. INSTRUCTIONS: FlexiBTS: 1. Block/unblock the FSM/FBIA. 2. If that does not help, replace the FSM/FBIA. UltraSite/EUBB: 1. Block/unblock the WSMF. 2. If that does not help, replace the WSMF. 3. Block/unblock the WSPF. 4. If that does not help, replace the WSPF.
FAULT NAME FAULT ID MEANING
: POST test failed : 69: EFaultId_Post_test_failedAl : A failure in the unit/module has been detected during the BTS power-on self test (POST). INSTRUCTIONS: 1. Block/unblock the alarming unit/module. 2. Remove/re-insert the alarming unit/module. 3. Replace the alarming unit/module. FlexiLiteBTS: 1. Replace the FlexiLiteBTS.
FAULT NAME FAULT ID MEANING
: PPS reference missing : 1898: EFaultId_PpsRefMissAl : The reference clock monitoring has detected a loss of PPS signal in the reference received from the GPS receiver. INSTRUCTIONS: FlexiBTS: 1. Check the GPS receiver installation. 2. Check the GPS receiver status. 3. Check connection between the GPS receiver and FSM. FlexiLteBTS: 1. Check the GPS receiver installation. 2. Check the GPS receiver status. 3. Check connection between the GPS receiver and Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: Parallel Interference Cancellation stream failure detected : 2310: EFaultId_PicStreamFailure : RACH RAKE sends this fault when Parallel Interference Cancellation stream failure is detected. INSTRUCTIONS: FlexiBTS: Note! Perform the steps below in the listed order until the fault disappears. 1. Reset the System Module. 2. Replace the System Module. UltraSite/EUBB:
98
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7651 BASE STATION OPERATION DEGRADED
1. If only one WSPF in the BTS generates this fault, the WSPF is faulty. 2. If all WSPFs generate this fault, the BTS is faulty. 3. Block/unblock the BTS. 4. If that does not help, replace the faulty module.
FAULT NAME FAULT ID MEANING
: Parallel RP3-01 link length mismatch : 4072: EFaultId_ParallelLinkDifferenceTooLargeAl : The parallel RP3-01 links towards one radio module have too large mutual length difference (more than 60 meters). INSTRUCTIONS: Replace parallel RP3-01 fiber links towards one radio module so that the maximum mutual length difference between fibers is less than 60 meters.
FAULT NAME
: Performance not optimal due to Rel2 ESM HSPA capability not utilized FAULT ID : 150: EFaultId_PerformanceNotOptimalRel2HspaCapabilityNotUsedAl MEANING : After Extension System Module is lost and 10 minutes timer expires, Telecom tries to re-allocate cells to Master System Module without HSPA capability. When the Extension System Module is back and if any cells have successfully been re-allocated to Master System Module, the performance is not optimal, because its HSPA capability is not utilized. Used in FSMr2+FSMr2, FSMr3+FSMr2 configurations. INSTRUCTIONS: In order to restore full performance reset BTS manually or lock-unlock all cells re-allocated from Extension System Module to Master System Module.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
Power unit input voltage fault 1302: EfaultId_WpsPwrInVoltage The input voltage of the BTS has decreased. 1. Check the other MAINS related active alarms. 2. Check the power supply voltage. If it is OK, replace the power cable. 3. Check the power unit.
FAULT NAME FAULT ID MEANING
: Power unit output voltage fault : 1301: EFaultId_WpsPwrOutVoltage : The output voltage is too low or too high. Usually the reason for the fault is the unit itself but in some cases the reason can be the unit that the WPS feeds. If a short circuit occurs in the fed unit, it may affect the WPS and the "Output Voltage Fault" alarm is generated. INSTRUCTIONS: 1. Check the other active alarms. 2. Check the units that are supplied by the alarming WPS.
DN99580892
Id:0900d805809d5c0d Confidential
99
7651 BASE STATION OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
3. Check the backplane connectors and cables. 4. Replace the alarming WPS unit.
FAULT NAME FAULT ID MEANING
: R-bus error : 425: EFaultId_RbusError : UltraSite, MetroSite, MetroSite 50, Triple-mode: The bus between the WSP and WTR does not work. The R-bus errors are probably caused by a faulty WSM or WTR. FlexiBTS: Error in the FSP or in the connection between the FSP and FCM. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode: 1. If the WSM/WMC also generates an alarm from a WTR unit, check the WTR and WSM cable. 2. If there are no active WSM/WMC alarms, the reason for the alarm is a faulty WSM/WMC or WSP. 3. Run a WCDMA BTS loop test to locate the faulty unit. 4. If the WSP is faulty, block/unblock it. 5. Replace the faulty unit. FlexiBTS: 1. Check the cabling between the System Module and RF Module. 2. Check the active RF Module alarms and act accordingly. 3. Replace the faulty module (System Module).
FAULT NAME FAULT ID MEANING
: RP3-01 Link Conflict : 4039: EFaultId_Rp301LinkConflictAl : FSM notices a shared radio module is connected to different OptIF connectors on peer system modules. INSTRUCTIONS: RP3-01 cabling from peer system modules to shared radio module is to be corrected.
FAULT NAME FAULT ID MEANING
: Radio Master Conflict : 4038: EFaultId_RadioMasterConflictAl : FSM should be the radio master for RFSW, but notices that RFSW already has another radio master defined. INSTRUCTIONS: Commissioning error. Only one System Module shall be set as master for particular radio resource.
FAULT NAME FAULT ID MEANING
: Resource block not available : 145: EFaultId_ResourceBlockNotAvailableAl : If there are no DSP resources for PIC configuration, Telecom rejects the PIC configuration and raises an alarm to indicate "Resource block not available". INSTRUCTIONS: 1) When the fault is detected, a new PIC configuration is to be provided by the BTS Site Manager. 2) If this is a repetitive problem, the FSP card has to be removed and re-inserted.
100
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7651 BASE STATION OPERATION DEGRADED
FAULT NAME FAULT ID MEANING
: Resource block occupied by high priority services : 146: EFaultId_ResourceBlockOccupiedAl : If PIC configuration cannot be allocated to a DSP resource because the DSP is in use with some high-priority users, Telecom raises this fault. Telecom then tries to move the high-priority users to a different resource block and tries again to allocate PIC configuration to the DSP a number of times for 3 minutes. In case of failure, Telecom rejects the received configuration to indicate "Resource block occupied by high priority users". INSTRUCTIONS: 1) The alarm indicates that the PIC configuration has failed. New PIC pool configuration is to be provided by the BTS Site Manager. 2) If this is a repetitive problem, the FSP card has to be removed and re-inserted.
FAULT NAME FAULT ID MEANING
: SFN Signal error : 2036: EFaultId_Transu_SfnSignalAl : A system frame number reception fault, an illegal SFN value in uplink. INSTRUCTIONS: 1. If only one FSP in the BTS generates this alarm, the FSP is faulty. 2. If all FSPs generate this alarm, the FSM is faulty. 3. Block/unblock the FSM. 4. If that does not help, replace the faulty module (System Module).
FAULT NAME FAULT ID MEANING
: SFN synchronization failure : 41: EFaultId_WSPC_PPC_SFN_PollingSynchAl : UltraSite, MetroSite, MetroSite 50, Triple-mode: The WSP is not synchronized with the WAM. FlexiBTS: The FSP/FBIA is not synchronized with the FCM. FlexiLiteBTS: The FSP is not synchronizaed with the SCR UltraSite/EUBB: The WSPF is not synchronized with WSMF. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode: 1. Block/unblock the alarming unit. 2. Replace the alarming unit. UltraSite/EUBB: 1. Block/unblock the EUBB subrack. 2. Replace the alarming unit. FlexiBTS: 1. Block/unblock the alarming module. 2. Replace the system module/plug-in FSP. FlexiLiteBTS: 1. Reset the BTS 2. Replace the FlexiLiteBTS unit
DN99580892
Id:0900d805809d5c0d Confidential
101
7651 BASE STATION OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
SFN synchronization failure 44: EFaultId_ATM_SFN_PollingSynchAl There is a WAM internal synchronization failure. 1. Check and correct the ATM configuration. 2. Replace the WAM.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
SFN synchronization failure 46: EFaultId_WAM_SFN_PollingSynchAl The slave WAM is not synchronised with the master WAM. 1. Block/unblock the alarming unit.
2. If that does not help, replace the alarming unit.
FAULT NAME FAULT ID
: SRAM operation failure : 1875: EFaultId_SRAMRdAl 1876: EFaultId_SRAMWrAl MEANING : SRAM memory operation failure. If this alarm appears continuously, the SRAM chip may be broken. INSTRUCTIONS: 1. Check the other active alarms. 2. Replace the alarming module.
FAULT NAME FAULT ID MEANING
: SRIO chain configuration was rejected : 4015: EFaultId_Srio_ConfFailedAl : The platform SW rejected the baseband bus related SRIO configuration for Faraday core. INSTRUCTIONS: Replace the alarming unit/module.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
FAULT NAME FAULT ID
MEANING
102
SRIO link Degradation 2326: EFaultId_SrioLinkDegradation SRIO error rate too high FlexiBTS: 1. Block/unblock the FSM. 2. If that does not help, replace the faulty module (System Module).
: SW fallback : 4082: EfaultId_FallbackDueToMaxResetLoopCounterValueAl 4083: EFaultId_FallbackDueToConfigurationDataMigrationFailureAl 4085: EfaultId_FallbackDueToTransportRequestAl : 4082: Source unit has reached the maximum number of reset attempts, that is the source unit cannot successfully
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7651 BASE STATION OPERATION DEGRADED
finish start-up after the SW update. 4083: Source unit requests SW fallback due to a critical problem that occurred in start-up after the SW update, that is configuration data migration failed. 4085: Transport SW on the source unit indicates a need for software fallback. INSTRUCTIONS: If the BTS is not automatically updated by NetAct and SW versions are inconsistent, update SW to the BTS with SW version running on BTS before SW update causing SW fallback.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
Self test failed 1882: EFaultId_SelfTestFailedAl The self test of the unit/module has failed. 1. Block/unblock the alarming unit/module. 2. If that does not help, replace the alarming unit/module.
FAULT NAME FAULT ID MEANING
: Summing not enabled for message type : 2059: EFaultId_MuksuSummingNotEnabledAl : Summing checks headers of the messages to be summed. If the header is not any of the allowed types, no summing is performed and an empty message is sent instead. INSTRUCTIONS: If FCM is the source: Reset FCM unit.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
Summing service release from reset failed 1891: EFaultId_MuksuReleaseFromResetFailedAl Summing service release from reset failed. 1. Reset the System Module. 2. If a reset does not resolve the fault situation, replace the System Module.
FAULT NAME FAULT ID
: Synchronization error in RP1 receiver : 2048: EFaultId_Casa2Rp1CrcAl 2049: EFaultId_Casa2Rp1FramePhaseAl MEANING : The frame alignment is lost or the frame burst has a CRC error when the System Module is working in extension mode. INSTRUCTIONS: 1. Check the other active synchronization alarms and act accordingly. 2. Reset the Extension System Module.
FAULT NAME FAULT ID MEANING
DN99580892
: Synchronization failure : 2030: EFaultId_Transu_CompDevBbRfAl : The frame burst phase has moved compared to the internal
Id:0900d805809d5c0d Confidential
103
7651 BASE STATION OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
counter. The FSM has already found the frame synchronization but the FSM frame clock does not match the FSM internal frame clock. INSTRUCTIONS: 1. If only one FSP in the BTS generates this alarm, the FSP is faulty. 2. If all FSPs generate this alarm, the FSM is faulty. 3. Block/unblock the FSM. 4. If that does not help, replace the faulty module (System Module).
FAULT NAME
: Synchronization failure in Optical Interface FAULT ID : 2005: EFaultId_OIC_SyncChAl MEANING : The RP3 channel has lost the frame synchronization state that it had achieved. INSTRUCTIONS: Swap the alarming and working links and then check where the alarm is now reported. If the alarming link remains the same, replace the System Module. If the alarming link changes, replace the RF Module behind that link.
FAULT NAME FAULT ID MEANING
: System Module failure : 3000: EFaultId_SystemModuleFailure : The Flexi BTS has detected an abnormal operation or a failure in the internal functionality of the System Module. The Flexi Lite BTS has detected an abnormal operation or a failure in the internal functionality of the BTS. INSTRUCTIONS: Note: Perform the steps below in the listed order. Flexi BTS: 1. Check cables between the modules and replace them if needed. 2. Reset the System Module. 3. Replace the System Module. Flexi Lite BTS: 1. Reset the BTS. 2. Replace the Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: System clock for extension system module not available : 1852: EFaultId_SystemClockExtensionNotAvailableAl : The Extension System Module does not receive the system clock. INSTRUCTIONS: 1. Connect to the Extension System Module with BTS Site Manager to check if there are optical interface alarms. 2. If there are, follow the instructions for those alarms. 3. If there are no optical interface alarms, replace the module.
FAULT NAME
104
: System frame clock signal missing
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7651 BASE STATION OPERATION DEGRADED
FAULT ID MEANING
: 219: EFaultId_SfclkMssAl : The WAM does not receive a system frame clock (SFCLK) from the WCI/WMC, because of the transceiver circuit in the WCI, the receiver circuit in the WAM, or the system frame clock bus is faulty. INSTRUCTIONS: 1. Block/unblock the alarming unit (WAM). This ensures that nothing unexpected has happened in the unit start-up phase. 2. If that does not help, replace the alarming unit (WAM).
FAULT NAME FAULT ID MEANING
: TRANSU synchronization error : 2045: EFaultId_TransuSyncAl : The RP3 TX/RX state machine or the T-bus receiver has changed its state. The synchronization is lost or the T-bus receiver has not synchronized. INSTRUCTIONS: 1. If only one FSP in the BTS generates this alarm, the FSP is faulty. 2. If all FSPs generate this alarm, the FSM is faulty. 3. Block/unblock the FSM. 4. If that does not help, replace the faulty module (System Module).
FAULT NAME FAULT ID MEANING
: TargetId verification failure : 4056: EFaultId_TargetIdVerificationFailureAl : NetAct Licence Manager did not respond to the verification request. TargetId verification was not possible. INSTRUCTIONS: Note! Perform the steps below in the listed order until the fault disappears. 1. Reset the NetAct Licence Manager. 2. Reset the BTS. 3. Check the BTS license situation: the correct licenses have been purchased and installed.
FAULT NAME FAULT ID MEANING
: Tbus receiver parity fault : 2027: EFaultId_Transu_TbusParityAl : Data or synchronization failure in the System Module, two antenna carriers are affected. INSTRUCTIONS: 1. If only one FSP in the BTS generates this alarm, the FSP is faulty. 2. If all FSPs generate this alarm, the FSM is faulty. 3. Block/unblock the FSM. 4. If that does not help, replace the faulty module (System Module).
FAULT NAME FAULT ID
DN99580892
: Telecom configuration failure : 109: EFaultId_TcomSlaveRegAl 110: EFaultId_UnitRnwConfigAl
Id:0900d805809d5c0d Confidential
105
7651 BASE STATION OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
111: EFaultId_TcomSlaveConfigAl 119: EFaultId_WspAllocationAl : Telecom
MEANING slave configuration or registration failure. Unit RNW configuration failure. Telecom RNW reconfiguration failure. FlexiBTS: - FSP unit to FCM allocation failure - Faraday unit to FSP allocation failure Note that depending on the fault source, unit status might relate either to the state of particular carrier resource on FR module or FSP board on FCM, and may not be in line with the state of source HW unit. Or UltraSite, MetroSite, MetroSite 50, Triple-mode: WSP unit to WAM allocation failure. UltraSite/EUBB: Faraday unit to WSPF allocation failure. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: Block/unblock the alarming unit. If there was an internal failure, the unit needs to be blocked/unblocked to get it initialized/configured again. UltraSite/EUBB: If the alarming unit is WSPF, block/unblock the EUBB subrack. FlexiBTS: If there was an internal failure, in the case of an FR, the module needs to be blocked/unblocked to get it initialized/configured again. FlexiBTS Rel2: If the alarming unit is FSPC, block/unblock the alarming module.
FAULT NAME FAULT ID MEANING
: Ten consecutive Nacks received from a DSP at DCH setup : 149: EFaultId_DspNacksReceivedAl : One particular DSP Nacks DCH setup 10 times with cause "NotEnoughResources=10" or "AlreadyActivated_Allocated=22" within a 20 minute period. INSTRUCTIONS: FlexiBTS: If the faulty FSP is in the extension module, block/unblock the extension module, otherwise block/unblock the BTS. FlexiLiteBTS: 1. Block/unblock Flexi Lite BTS. 2. Replace the Flexi Lite BTS.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
106
Timeout, commissioned resource not ready 35: EFaultId_UnitIsNotInUse The faulty unit has not been configured or initialised. Recommission the site.
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7651 BASE STATION OPERATION DEGRADED
FAULT NAME FAULT ID
: Transmission clock missing : 1003: EFaultId_TransmissionClk0Mss 1004: EFaultId_TransmissionClk1Mss MEANING : The clock of the BTS, the WSC/WMC unit, uses the Iub or the signal received from an external clock as a clock reference. The signal is routed through the AXC and WCI to the WSC. This alarm is generated if the WCI does not receive the clock reference signal. INSTRUCTIONS: 1. Check the other transmission-related alarms, for example link breaks. 2. Check the AXC settings. 3. Check the transmission cablings. 4. Replace the WCI unit.
FAULT NAME FAULT ID MEANING
: Transmission clock missing : 1816: EFaultId_Trans_Clk_MsgAl : The reference clock monitoring has detected a loss of signal in the reference received from the FT. INSTRUCTIONS: 1. Check the Iub connection. 2. Check the FT status. 3. Check the connection between the FT and FSM.
FAULT NAME FAULT ID
: Transmission parameters missing : 1825: EFaultId_PublicIPmissingAl 1826: EFaultId_TrParamMissingAl MEANING : A request to retrieve the public IP address information of the FCM/FCT from the FT fails, or transmission parameters have not been commissioned or properly set. INSTRUCTIONS: Commission the transmission with the correct parameters, either with a commissioning file or manually.
FAULT NAME FAULT ID MEANING
: Transmission rule collision in Muksu : 2060: EFaultId_MuksuTransmissionRuleCollisionAI : Transmitter detected an RP3 message from a summing coincident with a transmission rule. INSTRUCTIONS: 1. Check antenna mapping to the local cells in the commissioning file. 2. Replace the alarming module.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
DN99580892
Unit SW download failed 1824: EFaultId_AtmPostFailAl The software update to the unit or subunit has failed. 1. Reset the BTS. 2. If Step 1 does not help, replace the alarming unit. OR 1. Download the BTS SW again.
Id:0900d805809d5c0d Confidential
107
7651 BASE STATION OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
FAULT NAME FAULT ID MEANING
: Unit SW download failed : 6: EFaultId_SwDownloadAl : Software update to a unit/subunit or module has failed. UltraSite, MetroSite: The fault can also be caused by disconnected CIF bus cables. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: 1. Download the BTS SW again. 2. If the alarming unit is WSP, block/unblock the WSP. 3. If the alarming unit is WAM or WPA, reset the BTS. 4. If that does not help, replace the alarming unit. FlexiBTS: 1. Download the BTS SW again. 2. FCM: Reset the BTS. 3. If Step 2 does not help, replace the alarming module. FlexiLiteBTS: 1. Download the BTS SW again. 2. Reset the BTS. 3. If Step 2 does not help, replace the Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: Unit blocked : 48: EFaultId_UnitBlockedAl : A unit is blocked with BTS Site Manager. The purpose of the fault is to avoid alarms that might be raised during the unit maintenance task. INSTRUCTIONS: To cancel the alarm, unblock the unit/module.
FAULT NAME FAULT ID
: Unit initialization failure : 12: EFaultId_TcomConfigAl 13: EFaultId_AtmConfigAl 15: EFaultId_InitializationAl 4040: EFaultId_InitFaultManAl MEANING : A unit/module or an IP address initialization has failed. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: 1. Block/unblock the alarming unit. 2. Check if the non-commissioned WAM is the Master WAM. If so, this causes the fault. Check the fault history to find out why the WAM switch-over occurred. 3. If the WAM is the fault source, check the RNC IP address in the commissioning file and modify the file if needed. If that does not help, perform a power-off reset. 4. If step 3 does not help, replace the alarming unit. FlexiBTS: 1. Block/unblock the alarming module. If that does not help, replace the alarming module. 2. If the FCM/FCT is the fault source, check the RNC IP
108
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7651 BASE STATION OPERATION DEGRADED
address in the commissioning file and modify the file if needed. If that does not help, perform a power-off reset. 3. If Step 2 does not help, replace the alarming module. FlexiLiteBTS: 1. Block/unblock the alarming module. If that does not help, replace the alarming module. 2. If the SCR is the fault source, check the RNC IP address in the commissioning file and modify the file if needed. If that does not help, perform a power-off reset. 3. If Step 2 does not help, replace the alarming module.
FAULT NAME FAULT ID MEANING
: Unit initialization failure : 85: EFaultId_WSP_no_resp_from_PPC : The connection to the WSP fails because of a WSP internal failure. INSTRUCTIONS: 1. Block/unblock the alarming unit. 2. Replace the alarming unit.
FAULT NAME FAULT ID MEANING
: Unit not supported by current BTS SW version : 95: EFaultId_NotSupportedUnit : An unsupported unit has been detected in the BTS. Typically, this happens when a new unit version is installed and there is older BTS SW in use that does not support the new unit version. INSTRUCTIONS: FlexiBTS, UltraSite/EUBB:: 1. Upgrade the system module SW. 2. Replace the unit. FlexiLiteBTS: 1. Upgrade the Flexi Lite BTS software. 2. Replace the Flexi Lite BTS.
FAULT NAME : Unit synchronization failed FAULT ID : 16: EFaultId_SynchronizationAl MEANING : UltraSite, MetroSite, MetroSite 50, Triple-mode: The WAM/WSPC synchronization has failed. FlexiBTS: FCM/FCT/FSP synchronization has failed. INSTRUCTIONS: 1. Block/unblock the alarming unit. 2. Replace the alarming unit. FlexiLiteBTS: 1. Block/unblock the Flexi Lite BTS. 2. Replace the Flexi Lite BTS.
FAULT NAME FAULT ID
DN99580892
: Unknown Cabinet Type : 1804: EFaultId_UnknownCabinetTypeAl
Id:0900d805809d5c0d Confidential
109
7651 BASE STATION OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
MEANING
: The cabinet cannot be identified by its product code (or object ID). The problem is probably in the WID id. INSTRUCTIONS: Check the WID connection and replace the WID, if necessary.
FAULT NAME FAULT ID MEANING
: Unknown HW resource : 94: EFaultId_UnknownUnitType : A unit cannot be identified by its product code or by its physical device address (object ID). INSTRUCTIONS: FlexiBTS: Replace the alarming unit/module. FlexiLiteBTS: Replace the Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: Unknown product code : 93: EFaultId_UnknownProductCode : A module cannot be identified by its product code but is known by its physical device address (object_ID). INSTRUCTIONS: UltraSite/EUBB: Replace the alarming module. FlexiBTS: Replace the alarming module. FlexiLiteBTS: Replace the Flexi Lite BTS.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
Uplink data buffer synchronization failure 2033: EFaultId_Transu_UlDbSyncChAl The uplink data buffer loses synchronization. 1. If only one FSP in the BTS generates this alarm, the FSP is faulty. 2. If all FSPs generate this alarm, the FSM is faulty. 3. Block/unblock the FSM. 4. If that does not help, replace the faulty module (System Module).
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
WAM SFN polling timeout 47: EFaultId_WAM_SFN_PollingTimeoutAl The slave WAM is not synchronised with the master WAM. 1. Block/unblock the alarming unit. Note: After the WAM block/unblock, the BTS will be restarted. 2. If that does not help, replace the alarming unit.
FAULT NAME FAULT ID MEANING
: WAM internal error : 300: EFaultId_AtmRmCommAl : The C-Plane Telecom SW does not communicate with the C-Plane TUPC SW because of a fault. INSTRUCTIONS: Replace the faulty unit
FAULT NAME FAULT ID
110
: WMC oven oscillator fault : 8: EFaultId_DacWordLimitAl
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7651 BASE STATION OPERATION DEGRADED
MEANING
: The oven oscillator adjusting area is reaching its limit value. The alarm is activated if the WMC tunes the oven oscillator so that the DAC word (parameter to control the oven oscillator output frequency) value becomes lower than 205 or greater than 3891 (5 of the total adjustment area). The range for the DAC word is 0 - 4095. The cause of the alarm can be: - The Iub reference frequency has been incorrect for a long time (up to several days) due to a fault in the transmission network synchronisation (which in turn is caused by an equipment fault or a setting error). Before activating this alarm, the alarm 7652 BASE STATION NOTIFICATION: 'Difference between BTS master clock and reference frequency' may have been active. - If the BTS integrated transport part receives the synchronisation information via the 2.048 MHz synchronisation input (external clock source), the alarm situation may be caused by a fault in that signal. In that case the alarm behaviour notifications listed with the Iub signal (see above) are also valid in this case. - The fast tuning action of the BTS master clock may have been executed without checking if the reference signal is correct or not. If the reference signal is incorrect during the fast tuning execution, it may result in adjusting the BTS master clock frequency far from the nominal value, which causes serious problems in the network performance. - There is an equipment fault in the BTS. - Due to the oven oscillator (OCXO) aging inside the WSC unit, the unit may be approaching the end of its lifetime. In such case, after the alarm activation, the DAC value is quite stable, whereas in the other fault cases it may be very unstable or at the edge of the adjustment area (0 or 4095). Note that if the alarm 7651 BASE STATION OPERATION DEGRADED: 'WMC oven oscillator fault' becomes active, it may cause the alarm 7652 BASE STATION NOTIFICATION: 'Difference between BTS master clock and reference frequency' to cancel. INSTRUCTIONS: 1. In case of a fault in the transmission network synchronisation, the network synchronisation must be corrected. The long-term accuracy of the Iub signal must be 0.015 ppm or better. 2. In case of a BTS equipment fault, the location may be: a. Transport part - First check the alarms of the AXC node with the AXC Manager and act accordingly. - If there are no alarms, check the AXC synchronisation settings. b. WMC unit - If both the Iub reference signal accuracy and the AXC node are in order but the WMC unit is still alarming, run
DN99580892
Id:0900d805809d5c0d Confidential
111
7651 BASE STATION OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
the fast tuning procedure with the BTS Site Manager. - If there is no cure in a few minutes, reset the site. - If that does not help, replace the WMC unit. 3. After the fault situation has been cleared, the BTS master clock may also require tuning, because the BTS master clock adjustment is quite slow. The tuning may be done: - Manually, by changing the DAC word (during a site visit). - Or with fast tuning, by which the BTS master clock is tuned in a few minutes automatically near the Iub reference (normal tuning takes care of the fine tuning). Note, however, that the fast tuning should only be used in case the Iub reference signal is known to be a good one. Otherwise the BTS frequency may be tuned into a totally incorrect value, causing serious problems in the network performance. Background information: The principle is that in a mobile network, the synchronisation goes from MSC => RNC => BTS. But in reality that chain might be broken somewhere and, for example, when using leased lines, the BTS may take the reference synchronisation from the transmission network of another operator. This does not harm the system if also the synchronisation of the leased line service provider is accurate/stable enough. The BTS uses the incoming synchronisation signal as a reference for the Air interface, the accuracy requirement of which is set by 3GPP.
FAULT NAME FAULT ID MEANING
: WSC oven oscillator fault : 907: EFaultId_DualWscDacWordAlarm : The oven oscillator adjusting area is reaching its limit value. The alarm is activated if the WSC tunes the oven oscillator so that the DAC word (parameter to control the oven oscillator output frequency) value becomes lower than 205 or greater than 3891 (5 of the total adjustment area). The range for the DAC word is 0 - 4095. The cause of the alarm can be: - The Iub reference frequency has been incorrect for a long time (up to several days) due to a fault in the transmission network synchronization (which in turn is caused by an equipment fault or a setting error). Before activating this alarm, the alarm 7652 BASE STATION
NOTIFICATION: 'Difference between BTS master clock and reference frequency' may have been active. - If the BTS integrated transport part receives the synchronization information via the 2.048 MHz synchronization input (external clock source), the alarm
112
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7651 BASE STATION OPERATION DEGRADED
situation may be caused by a fault in that signal. In that case, the alarm behavior notifications listed with the Iub signal (see above) are also valid in this case. - The fast tuning action of the BTS master clock may have been executed without checking if the reference signal is correct or not. If the reference signal is incorrect during the fast tuning execution, it may result in adjusting the BTS master clock frequency far from the nominal value, which causes serious problems in the network performance. - There is an equipment fault in the BTS. - Due to the oven oscillator (OCXO) aging inside the WSC unit, the unit may be approaching the end of its lifetime. In such case, after the alarm activation, the DAC value is quite stable, whereas in the other fault cases it may be very unstable or at the edge of the adjustment area (0 or 4095). Note that if the alarm 7651 BASE STATION OPERATION DEGRADED: 'WSC oven oscillator fault' becomes active, it may cause the alarm 7652 BASE STATION NOTIFICATION: 'Difference between BTS master clock and reference frequency' to cancel. INSTRUCTIONS: 1. In the case of a fault in the transmission network synchronization, you need to correct the network synchronization. The long-term accuracy of the Iub signal must be +/- 0.015 ppm or better. 2. In case of BTS equipment fault, the location may be: 2.1 Transport part - First check the alarms of the AXC node with AXC Manager and act accordingly. - If there are no alarms, check the AXC synchronization settings. 2.2 WSC unit - If both the Iub reference signal accuracy and the AXC node are in order but the WSC unit is still alarming, run the fast tuning procedure with BTS Site Manager. - If that does not solve the problem in a few minutes, reset the site. - If that does not help, replace the WSC unit. Note: In case the BTS is equipped with two WSCs, the redundant unit takes over the operation of the faulty unit. But if the fault situation is caused by an incorrect reference signal, both the WSC units may start alarming sooner or later. 3. After the fault situation has been cleared, the BTS master clock may also require tuning, because the BTS master clock adjustment is quite slow. You can perform the tuning: - manually, by changing the DAC word (during a site visit), or - with fast tuning, where the BTS master clock is tuned automatically in a few minutes near the Iub reference (normal tuning takes care of the fine tuning)
DN99580892
Id:0900d805809d5c0d Confidential
113
7651 BASE STATION OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
Note, however, that the fast tuning should only be used in case the Iub reference signal is known to be a good one. Otherwise the BTS frequency may be tuned into a totally incorrect value, causing serious problems in the network performance. Background information: The principle is that in a mobile network, the synchronization goes from MSC > RNC > BTS. But in reality that chain might be broken somewhere and, for example, when using leased lines, the BTS may take the reference synchronization from the transmission network of another operator. This does not harm the system if also the synchronization of the leased line service provider is accurate/stable enough. The BTS uses the incoming synchronization signal as a reference for the Air interface, the accuracy requirement of which is set by 3GPP.
FAULT NAME FAULT ID MEANING
: WSC phase difference jammed to zero reading : 22: EFaultId_WscPhaseDiffJammedAl : The WSC phase measurement is jammed and the tuning operation is degraded. The problem can be caused by a WSC fault, or a too fast frequency change on the Iub. INSTRUCTIONS: 1.If the basic accuracy of the Iub signal is in order but there is too much instability, that is, the jitter/wander is outside the acceptable limits, the synchronization of the transmission network must be corrected. The limits for the jitter/wander are defined in the ITU-T G.823. No actions on the BTS are needed. 2. Reset the site and wait about 10 minutes. 3. Try a power-on reset. If the alarm reappears, replace the unit. If the alarm reappears during the next few weeks or the clock seems unstable, replace the unit. Background information: The principle in the mobile network is that the synchronization goes from MSC => RNC => BTS. But in reality that chain might be broken somewhere and, for example, when using leased lines the BTS may take the reference synchronization from the transmission network of another operator. This does not harm the system if also the synchronization of the leased line service provider is accurate/stable enough. The BTS uses the incoming synchronization signal as a reference for the Air interface, the accuracy requirement of which is set by 3GPP.
FAULT NAME FAULT ID
114
: WSC/WMC transmission clock missing : 900: EFaultId_TransmissionClkMss 909: EFaultId_DualWscTrclkMss
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7651 BASE STATION OPERATION DEGRADED
MEANING
: The clock of the BTS, the WSC/WMC unit, uses the Iub or the signal received from an external clock as a clock reference. The signal is routed through the AXC and WCI to the WSC. This alarm is generated if the WCI does not receive the clock reference signal. INSTRUCTIONS: 1. Check the other transmission-related alarms, for example link breaks. 2. Check the AXC settings. 3. Check the transmission cablings. 4. Replace the WCI unit.
FAULT NAME FAULT ID
MEANING
: WSM SR-Bus error : 1205: EFaultId_Srl0_0ParityErr2 1207: EFaultId_Srl0_0SyncErr2 1209: EFaultId_Srl0_1ParityErr2 1211: EFaultId_Srl0_1SyncErr2 1213: EFaultId_Srl1_0ParityErr2 1215: EFaultId_Srl1_0SyncErr2 1217: EFaultId_Srl1_1ParityErr2 1219: EFaultId_Srl1_1SyncErr2 1221: EFaultId_SRr0_0ParityErr2 1223: EFaultId_SRr0_0SyncErr2 1225: EFaultId_SRr0_1ParityErr2 1227: EFaultId_SRr0_1SyncErr2 1229: EFaultId_Srr1_0ParityErr2 1231: EFaultId_Srr1_0SyncErr2 1233: EFaultId_Srr1_1ParityErr2 1235: EFaultId_Srr1_1SyncErr2 : UltraSite, UltraSite/EUBB: The RX signal is transported from the WTR unit to all WSP units via the WSMs. The WSM units in different subracks are connected to each other via the SR buses. This alarm is generated, when the WSM unit detects errors in the incoming SR bus from the adjacent WSM unit. The reason for the failure is the cable between the WSM front panels or the WSM units indicated in the alarm. Triple-mode: The RX signal is transported from the WTR30 and WRT20 units (connected to the SR bus) to the WSP units via the SR bus. This alarm is generated, when the WSM detects errors in the incoming SR bus from the WTR unit. The reason for the failure is the WSM or WTR unit, or the cable between the WSM front panel
and the backplane. INSTRUCTIONS: 1. Run the WCDMA BTS loop test. 2. Check the WSM cables. 3. Replace the units indicated in the alarm one by one and check whether the problem is cleared (see Troubleshooting instructions).
DN99580892
Id:0900d805809d5c0d Confidential
115
7651 BASE STATION OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
FAULT NAME FAULT ID
: WSM ST-Bus error : 1173: EFaultId_St_l0ParityErr2 1175: EFaultId_St_l0SyncErr2 1177: EFaultId_St_l1ParityErr2 1179: EFaultId_St_l1SyncErr2 1181: EFaultId_St_r0ParityErr2 1183: EFaultId_St_r0SyncErr2 1185: EFaultId_St_r1ParityErr2 1187: EFaultId_St_r1SyncErr2 MEANING : The TX signal is transported from the WSP unit to all WTR units via the WSMs. The WSM units in different subracks are connected to each other via the ST buses. This alarm is generated when the WSM unit detects errors in the incoming ST bus from the adjacent WSM unit. The reason for the failure is the cable between the WSM front panels or the WSM units indicated in the alarm. INSTRUCTIONS: 1. Run the WCDMA BTS loop test. 2. Check the WSM cables. 3. Replace the units indicated in the alarm one by one and check whether the problem is cleared (see Troubleshooting instructions).
FAULT NAME FAULT ID
: WSM T-Bus error : 1149: EFaultId_Wspc0ParityErr2 1151: EFaultId_Wspc0SyncErr2 1153: EFaultId_Wspc1ParityErr2 1155: EFaultId_Wspc1SyncErr2 1157: EFaultId_Wspc2ParityErr2 1159: EFaultId_Wspc2SyncErr2 1161: EFaultId_Wspc3ParityErr2 1163: EFaultId_Wspc3SyncErr2 1165: EFaultId_Wspc4ParityErr2 1167: EFaultId_Wspc4SyncErr2 1169: EFaultId_Wspc5ParityErr2 1171: EFaultId_Wspc5SyncErr2 MEANING : The signal is transported from the WSP unit to the WTR unit through the WSM. This alarm is generated when the WSM unit detects errors in the incoming T bus from the WSP unit. The reason for the failure is probably the WSP or WSM unit. The unit might have been installed incorrectly or the backplane cabling is faulty. INSTRUCTIONS: 1. Run the WCDMA BTS loop test. 2. Check the WSM cables. 3. Replace the units indicated in the alarm one by one and check whether the problem is cleared (see Troubleshooting instructions).
116
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7651 BASE STATION OPERATION DEGRADED
FAULT NAME FAULT ID
: WSM does not receive frame clock : 1253: EFaultId_Dsax_SfclkStatusNegErr 1254: EFaultId_Dsax_SfclkStatusPosErr 1256: EFaultId_Umax_SfclkStatusErr MEANING : The WSM does not receive the System Frame Clock (SFCLK) correctly from the WCI unit. This fault may appear if the only clock unit (WSC) is removed. INSTRUCTIONS: 1. Block/unblock the alarming WSM. Note! This will cause a BTS reset. 2. Replace the WCI unit and check whether the alarm is cleared. 3. Check the backplane cables and connectors.
FAULT NAME FAULT ID MEANING
: WSM failure : 3001: EFaultId_EubbWsmAl : The BTS has detected an abnormal operation or a failure in the internal functionality of the WSMF unit. INSTRUCTIONS: Note: Perform the steps below in the listed order until the alarm disappears. 1. Check the alarm history, alarming unit and subrack. 2. Check that the unit is properly connected. If the unit LED does not light up, the unit is faulty. 3. Reset the BTS. 4. Replace the alarming unit.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
WSMF WAM Interconnection Failure 4049: EFaultId_WsmfWamInterconnectionFailureAl Connection failure between WAMA and WSMF Check that cables are connected between WAMA-WSMF and WSMF-AXCF.
FAULT NAME FAULT ID
: WSP PCI-bus failure : 225: EFaultId_PCIInvalidDeviceAl 226: EFaultId_PCITargetNotFoundAl 227: EFaultId_PCITargetDSPAmountAl MEANING : There is a fault in the internal WSP/FSP PCI bus target (DSP) connections. Some of the WSP/FSP DSP processors may be broken and out of use. INSTRUCTIONS: Replace the alarming unit/module.
FAULT NAME FAULT ID MEANING
: WSP failure : 3002: EFaultId_EubbWspAl : BTS has detected an abnormal operation or a failure in the internal functionality of the WSPF unit. INSTRUCTIONS: Note: Perform the steps below in the listed order until the alarm disappears.
DN99580892
Id:0900d805809d5c0d Confidential
117
7651 BASE STATION OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
1. Check the alarm history, alarming unit and subrack. 2. Check that the unit is properly connected. If the unit LED does not light up, it is faulty. 3. Reset the alarming unit. 4. Replace the alarming unit.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
WSP unit internal failure 97: EFaultId_WamWspOutOfSyncAl The WAM and WSP are not synchronized. 1. Block/unblock the alarming unit. 2. If that does not help, replace the alarming unit. Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
118
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7652 BASE STATION NOTIFICATION
30 7652 BASE STATION NOTIFICATION Meaning A minor fault (or faults) has occurred in the base station. Check the reason for the fault from the supplementary text field of the alarm. The effect of the fault on the functioning of the network element depends on the fault description. For more information, see base station fault descriptions in WCDMA RAN and Flexi Direct System Libraries. Supplementary information fields 1
rack (cabinet) number
2
shelf number
3
slot
4
type of unit
5
unit number
6
subunit number
For more information, see instructions on Alarm Structure. Instructions Verify the configuration of a BTS by checking the commissioning, cabling and correct installation of the units/modules at the BTS. Make sure the environment does not cause the fault. Before a unit/module is replaced at the BTS, the site should be reset to recover from any temporary faults which might have caused the malfunctioning of the unit/module. When an active alarm is a 'Start' alarm, a site reset is required to cancel the alarm. If the site reset or module block/unblock does not help, replace the faulty unit/module (see source of the alarm and instructions fields of the corresponding alarms). Below is the list of BTS fault(s) which might have caused this alarm in WN 8.0 release. In case of earlier SW release and in case you need more detailed fault descriptions refer to WCDMA RAN and Flexi Direct System Libraries. The BTS fault descriptions are also included in BTS SW release documentation. If that does not help, contact your local
DN99580892
Id:0900d805809d5c0d Confidential
119
7652 BASE STATION NOTIFICATION
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
Nokia Siemens Networks representative.
FAULT NAME FAULT ID MEANING
: autonomous reset as recovery action : 52: EFaultId_UnitAutonomousResetAl : The BTS tries to correct a fault situation by performing a recovery reset to a unit, the site, or the BTS. INSTRUCTIONS: Check the alarm history and other active alarms of the unit. Note! This alarm does not require any (special) actions.
FAULT NAME FAULT ID MEANING
: 2M external reference missing : 1899: EFaultId_2MExtRefMissAl : The reference clock monitoring has detected a loss of 2.048 MHz signal received from an external reference source, connected to the Sync In interface of the System Module. INSTRUCTIONS: Note! Perform the steps below in the listed order until the alarm disappears. 1. Check the cabling (connected to Sync In interface). 2. Check that the 2.048MHz reference source is working normally and the 2.048 MHz signal is available. 3. Replace the alarming module.FlexiLiteBTS: Replace the Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: ATM cell loss : 306: EFaultId_CellLossAl : ATM cells are lost. The cell loss can be caused by a traffic overload, by the WAM receiving an invalid ATM cell or AAL5 packet, or by the data corruption on the Iub (that is, a bad BER). The most common causes for this alarm are transmission network problems (causing unnecessary WAM changes). INSTRUCTIONS: 1. Check that bandwidths (cells/s) are the same at the BTS, AXC and RNC. 2. Check the data integrity from the incoming Iub (see Troubleshooting instructions). 3. Check the other transmission elements' active alarms (see the Alarms for AXC document). 4. Check the WAM, AXU and the cabling between them.
FAULT NAME FAULT ID MEANING
: ATM, A2EA configuration error : 315: EFaultId_A2eaConfigAl : The RNC A2EA transport layer address does not comply with the given BTS A2EA address. This alarm is reported to the BTS Site Manager only. INSTRUCTIONS: Check and re-commission the AXC (if AAL2 multiplexing is in use), RNC or BTS with the correct BTS A2EA addresses.
120
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7652 BASE STATION NOTIFICATION
FAULT NAME FAULT ID MEANING
: Active clock tuning fault : 1831: EFaultId_ActiveClkTuningAl : The phase measurement cannot be performed in the active WSC or WMC. INSTRUCTIONS: 1. Run fast tuning with BTS Site Manager. 2. Block/unblock the alarming unit. 3. Replace the alarming unit. Note that because of a fault situation in the active clock, the redundant clock is not tuned. To make sure that the tuning is correct, run "Fast Tune BTS Clock" with BTS Site Manager after the switchover when the new WSC is taken into use. If there is a WMC or only one WSC, the tuning continues but the cells remain disabled.
FAULT NAME FAULT ID
: Antenna Line Device Operation Failure : 1871: EFaultId_BusyAl 1872: EFaultId_FormatErrorAl 1873: EFaultId_UnsupportedProcedureAl 1874: EFaultId_OutOfRangeAl MEANING : The device is not working properly, the configuration is not valid, or a given parameter is incorrect. INSTRUCTIONS: 1. Check the functionality of the antenna line device. 2. Check the compatibility between the antenna line device and the BTS. 3. Check that the given parameters are in the valid range.
FAULT NAME FAULT ID MEANING
: Antenna Line Device failure : 3100: EFaultId_AntennaLineFailure : The System Module or the device itself has detected an abnormal operation or a failure in the antenna line device. INSTRUCTIONS: Note: Perform the steps below in the listed order until the alarm disappears. 1. Check the antenna line and antenna line devices. Make sure that the antenna line connectors are in the right torque. 2. Reset the alarming RF module by blocking/unblocking it. 3. Replace the faulty parts and/or devices along the antenna line. 4. Replace the RF Module.
FAULT NAME FAULT ID MEANING
: Antenna line device HW failure : 1847: EFaultId_HardwareErrorAl : A hardware failure detected by an Usually this is a permanent fault INSTRUCTIONS: 1. Block/unblock the Radio module to the antenna line devices. 2. If that does not help, replace
DN99580892
antenna line device. (the hardware is broken). to give a power-off reset the antenna line device.
Id:0900d805809d5c0d Confidential
121
7652 BASE STATION NOTIFICATION
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
FAULT NAME FAULT ID
: Antenna line device configuration failure : 1848: EFaultId_WorkingSoftwareMissingAl 1888: EFaultId_AlConfigurationFailureAl MEANING : An antenna line or antenna line device is not properly configured. INSTRUCTIONS: 1. Update the proper SW to the device. 2. Check/correct the antenna line configuration. 3. If that does not help, replace the antenna line device.
FAULT NAME FAULT ID
: BTS file error : 1802: EFaultId_FileRequestFlashAl 1803: EFaultId_FileParsingFailedAl 1866: EFaultId_RulesMissingAl 1867: EFaultId_RulesParsingAl MEANING : UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: The BTS unit properties data is invalid or missing. FlexiBTS: The BTS module properties data or optical interface FPGA file is invalid or missing. The FSP MCU SW file is invalid or missing. FlexiLiteBTS: The BTS properties data or optical interface FPGA file is invalid or missing. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: 1. Download two different SW packages so that the faulty file is removed from the BTS. 2. Download the SW again. 3. If the fault still exists after 10 minutes, replace the alarming unit. FlexiBTS, FlexiLiteBTS: 1. Download two different SW packages so that the faulty file is removed from the BTS. 2. Download the SW again. 3. Replace the System Module.
FAULT NAME FAULT ID MEANING
122
: BTS reference clock missing : 3080: EFaultId_BtsReferenceClockMissing : This BTS fault indication is generated if the reference clock monitoring function of the BTS does not receive the highest configured synchronization reference signal or if all the synchronization reference signals are missing. The BTS fault is not generated if the highest configured synchronization source is present, no matter what the lower level source statuses are. Background information: There is a fixed synchronization priority list in the FlexiBTS:
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7652 BASE STATION NOTIFICATION
-Priority 1: PPS (Pulse Per Second) signal connected to the Synchronization Input interface (Sync In) of the System Module. Normally the PPS signal is generated by the GPS receiver. -Priority 2: external 2.048MHz signal connected to the Sync In interface. -Priority 3: the reference signal coming from the integrated transmission unit (FTM). Normally, all the FlexiBTS sources are not in use at the same time (it depends on the network planning and BTS configuration). During the BTS start-up, the available sources are checked against the reference source list in the BTS commissioning file and deviations regarding the missing highest priority source generate a fault. During runtime operation, the BTS fault functionality runs autonomously - notices also added/vanished sources which are missing from the commissioning file. The source for the FTM (which is the priority 3 source for the FlexiBTS) can be TDM interface signal (for example E1, T1...), physical layer Synchronous Ethernet (SyncE) signal or application layer Timing over Packet (ToP) in which the timing information to BTS(s) is generated by a ToP master. The FTM reference source priority selection is not fixed but user-selectable. Furthermore, if a signal listed in the FTM references is not received, a BASE STATION TRANSMISSION ALARM is reported. INSTRUCTIONS: Depending on the installed and commissioned synchronization source(s) listed in section "Meaning", see the commissioned synchronization option below and perform the steps in the listed order until the BTS fault indication disappears. GPS receiver (PPS source): 1. If there is a GPS receiver commissioned at the BTS site, note the following: If the GPS receiver is not locked to any satellite, it turns off the PPS signal which is normally delivered to the BTS (Sync In interface). The most common reason is that the GPS receiver does not see any satellites because of poor antenna installation (poor sky visibility). The only permanent cure for this is to change the GPS antenna location. One indication of a fairly poor sky visibility is that the BTS fault is activated/canceled every now and then. 2. There might be a malfunction in the GPS receiver. Perform a (remote) power reset for the GPS receiver. 3. There might be a malfunction in the BTS. Perform a BTS site reset. 4. The GPS cable and/or connectors might be damaged. Check the cable and the connectors. 5. There might be a HW fault in the GPS receiver. Check the operation and change the HW, if needed.
DN99580892
Id:0900d805809d5c0d Confidential
123
7652 BASE STATION NOTIFICATION
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
External 2.048MHz signal: 1. If there is an external 2.048MHz signal source commissioned at the BTS site, check the BTS faults of that device and act accordingly. If this does not help, check the cables. Note that since the device type is not known, detailed instructions cannot be given. For further actions refer to the appropriate user manual of the device. 2. There might be a malfunction in the BTS. Perform a BTS site reset. FTM reference (TDM, SyncE or ToP as source): 1. If there is an integrated transmission unit (FTM) commissioned at the BTS site, note the following: the FTM unit operates so that if it is not locked to a synchronization source, it turns off the clock reference signal which is normally delivered to the BTS master clock. The synchronization source of the FTM (set by the FTM synchronization priority setting) might be missing, causing the FTM internal clock to drop to holdover mode. In this case, the fault in the transmission network must be corrected (FTM itself might be working fine). 2. Check the alarms of the FTM unit and act accordingly. 3. Check the synchronization settings of the FTM unit. 4. There might be a malfunction in the BTS. Perform a BTS site reset. 5. There might be an equipment failure in the FTM unit. Check the operation and replace the unit, if needed. Note: Normally the reason is not an equipment failure, but there might be connection failures in the transmission or packet network, causing the FTM clock to drop to holdover mode. Especially the BTS fault indication activity (frequent BTS fault indication activations/cancels instead of a stable BTS fault indication state) points to the transmission network instability, not to a failure in the unit. If the previous steps do not help, there might be an equipment failure in the System Module. Check the operation and if resetting the BTS site does not help, replace the System Module.
FAULT NAME
: BTS reset needed to activate a license , FAULT ID : 1877: EFaultId_ResetNeededForLicenceAl MEANING : The license status has changed to valid and a BTS reset is needed to take the license into use. INSTRUCTIONS: Reset the BTS.
FAULT NAME FAULT ID MEANING
124
: BTS reset required : 4001: EFaultId_BtsResetNeededAl : The BTS detected an Extension Module as a capacity enhancement.
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7652 BASE STATION NOTIFICATION
The BTS detected an RF Module that cannot be taken into use without the BTS reset. The RF Module type differs from the previous one. INSTRUCTIONS: Reset (block/unblock) the BTS.
FAULT NAME FAULT ID MEANING
: BTS reset time increased : 4091: EFaultId_BtsResetTimeIncreasedAl : BTS has detected RF module power cycle failure and is trying to recover from the failure during BTS reset procedure. BTS reset lasts longer due to additional actions performed by BTS in order to recover from faulty situation. INSTRUCTIONS: None
FAULT NAME FAULT ID MEANING
: BTS time not corrected : 26: EFaultId_NtpTimeNotSetAl : The SNTP time cannot be fetched from the transport system (FT) within the time limit. INSTRUCTIONS: 1. Check the NTP setting. 2. Check the stratum parameter on the NTP server.
FAULT NAME FAULT ID MEANING
: Baseband Bus failure : 3020: EFaultId_BaseBandBusFailure : The BTS has detected an abnormal operation or a failure in the BTS internal baseband bus. The failure cannot be pointed to a specific unit/module but there are several possible fault sources. INSTRUCTIONS: Note: Perform the steps below in the listed order. FlexiBTS: 1. Check other active BTS alarms and act accordingly. 2. Check the cables between the System Module and RF Module/Extension System Module. 3. Reset the RF Module and/or System Module, depending on the alarm source: a. Reset the RF Module by blocking/unblocking it. b. Reset the Extension System Module by blocking/unblocking it. c. Reset the master System Module. 4. Replace the alarming RF Module/Extension System Module. 5. If the master System Module is the source or replacing the RF Module/Extension System Module does not clear the fault situation, replace the alarming master System Module. UltraSite/EUBB: 1. Check other active BTS alarms and act accordingly. 2. Reset the alarming unit. 3. Check the cables in backplane. 4. Replace the alarming unit. FlexiLiteBTS:
DN99580892
Id:0900d805809d5c0d Confidential
125
7652 BASE STATION NOTIFICATION
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
1. Check other active BTS faults and act accordingly. 2. Reset the BTS by blocking/unblocking it.
3. Replace the Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: Baseband reference clock missing (WSC) : 910: EFaultId_DualWscBrclkMss : The WSC is not able to deliver the clock signals required by the other units. INSTRUCTIONS: Replace the WSC.
FAULT NAME FAULT ID MEANING
: Baseband reset needed : 4109: EfaultId_BasabandResetNeeded : Unit containing common channel devices is being blocked. Baseband reset is needed to proceed with blocking. OR FSP is hot removed. Baseband reset is needed to proceed. INSTRUCTIONS: None
FAULT NAME FAULT ID MEANING
: Cabinet door open : 1300: EFaultId_DoorAl0 : The cabinet door is open or the cabinet door sensor is faulty. INSTRUCTIONS: 1. Ensure that the cabinet doors are properly closed. 2. Check that the door switches function correctly and that they have been adjusted correctly. Note: this alarm can be enabled or disabled in commissioning.
FAULT NAME FAULT ID MEANING
: Communication failure with RNC : 114: EFaultId_RncHoRespAl : The BTS does not receive a response from the RNC (a block request). INSTRUCTIONS: Check the signaling link settings and the RNC connections.
FAULT NAME FAULT ID MEANING
: Configuration error: : 3070: EFaultId_ConfigurationError : There is an incompatibility problem in the BTS HW/SW versions or the HW/HW configuration. Another possibility is that there is a mismatch between the BTS configuration and the RNC/Flexi Direct RNC parameters. INSTRUCTIONS: Note: Perform the steps below in the listed order. 1. Check the installed HW/SW version compatibility and the HW compatibility with the current BTS configuration. 2. Check that the BTS cell parameters from the RNC/Flexi
126
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7652 BASE STATION NOTIFICATION
Direct RNC match the BTS HW configuration (for example frequency, power). 3. Check the RNC/Flexi Direct RNC BTS faults for the alarming local cell (LCR). 4. Recommission the BTS to ensure that all parameters are correctly configured.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
Cooling fan broken 1933: EFaultId_FrFanBroken Fan/s is/are not running. 1. Make sure that the fan connector is properly mounted. 2. If that does not help, replace the fan module.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
Cooling fan broken 4078: EFaultId_FanBrokenAl Fan(s)are not running although control is higher than 0. 1. Check that the fan is not blocked. 2. Check that the fan connector is properly mounted. 3. If that does not help, replace the fan.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
Cooling fan has reduced from the set speed 1934: EFaultId_FrFanReducedSetSpeed Fan/s is/are rotating slower than required. 1. Make sure that the fan connector is properly mounted. 2. If that does not help, replace the fan module.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
Cooling fan is over speeding 4080: EFaultId_FanOverSpeedAl Fan(s) are running faster than requested. Replace the fan(s).
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
Cooling fan is over speeding 1935: EFaultId_FrFanOverSpeed Fan/s is/are rotating faster than required. Replace the fan module.
FAULT NAME FAULT ID MEANING
: Cooling fan out of order : 1917: EFaultId_FrFanOutOfOrder : The RF Module cooling fan is not rotating at the specified speed. INSTRUCTIONS: Note: Perform the steps below in the listed order until the alarm disappears. 1. Check the fan and cabling. 2. Block/unblock the RF Module. 3. Replace the faulty fan assembly.
DN99580892
Id:0900d805809d5c0d Confidential
127
7652 BASE STATION NOTIFICATION
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
Cooling fan speed decreased 4079: EFaultId_CoolingFanSpeedDecreasedAl Fan(s) speed is deviating too much from requested control. 1. Check that the fan is not blocked. 2. Check that the fan connector is properly mounted. 3. If that does not help, replace the fan.
FAULT NAME FAULT ID MEANING
: Difference between BTS master clock and reference frequency : 9: EFaultId_DacWordChangeAl : The reference frequency that the BTS master clock receives from the transport part has changed by about 0.2 ppm or more (which equals the change magnitude of 204 DAC steps or more) during the measurement period (about 20 minutes), compared to the BTS master clock frequency. The cause of the alarm can be: 1. The Iub reference frequency has changed due to a fault in the transmission network synchronization (which in turn is caused by an equipment fault or a setting error). Note that if the network synchronization malfunction lasts for a long time, the alarm is canceled when the BTS frequency reaches the faulty Iub synchronization. The alarm can also be activated if the faulty Iub synchronization is corrected and there is again the difference of 0.2 ppm or more. The alarm is canceled whenever the difference becomes smaller than 0.2 ppm. 2. The Iub reference frequency fluctuates continuously due to a great deal of jitter/wander in the transmission network. The alarm is continuously activated/canceled (however, the alarming state may predominate). There is always some jitter/wander in the transmission network; the limits are defined in ITU-T G.823/824/825. 3. If the BTS integrated transport part receives the synchronization information via the 2.048 MHz synchronization input (external clock source), the alarm situation may be caused by a fault of that signal. In that case, the alarm behavior notifications listed with the Iub signal (see above) are also valid in this case. 4. There is an equipment fault in the BTS. The equipment fault is, however, not the most common reason. Normally the reason can be found in the Iub/reference signal behavior (see the descriptions above). UltraSite, MetroSite, MetroSite 50, Triple-mode: Note that if the alarm 7651 BASE STATION OPERATION DEGRADED: 'WSC oven oscillator fault' becomes active, it may cause the alarm 7652 BASE STATION NOTIFICATION: 'Difference between BTS master clock and reference frequency' to cancel. INSTRUCTIONS: Because there are several possibilities for the alarm
128
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7652 BASE STATION NOTIFICATION
activation, a BTS Clock Frequency History feature has been developed. You can access the stored history data via BTS Site Manager. You can use the history data as a tool for finding out the reason for the fault/alarm situation (for further instructions about the history feature, see the online help of BTS Site Manager). Depending on the possible reason, follow the instructions below: 1. In case of a fault in the transmission network synchronization, you must correct the network synchronization. The long-term accuracy of the Iub signal must be 0.015 ppm or better (check the correct Iub accuracy by measuring it). No actions on the BTS are necessarily needed. 2. If the basic accuracy of the Iub signal is in order but there is too much instability, that is, the jitter/wander is outside the acceptable limits, you must correct the synchronization of the transmission network. The limits for the jitter/wander are defined in the ITU-T G.823/824/825. No actions on the BTS are needed. 3. In case of a BTS equipment fault, the location may be: Transport part: - First check the alarms of the AXC node with AXC Manager, or FTM and act accordingly.
- If there are no alarms, check the AXC/FTM synchronization settings. WSC/FCM unit: - If both the Iub reference signal accuracy and the AXC/FTM are in order but the WSC/FCM unit is still alarming, run the fast tuning with BTS Site Manager. - If the alarm is still active after the fast tuning is finished, reset the site. If the problem does not disappear in a few minutes, reset the site. - If that does not help, replace the WSC/FCM unit. Note that if the reason is in the transmission network synchronization, replacing the faulty unit does not correct the situation. Furthermore, the alarm activity (frequent alarms/cancels) points to an instability in the transmission network, not to a fault in the unit. 4. After the fault situation has been cleared, you might need to tune the BTS master clock because the BTS master clock adjustment is quite slow. You can perform the tuning: - manually by changing the DAC word (during a site visit) - or with fast tuning, in which the BTS master clock is tuned in a few minutes automatically near the Iub reference (normal tuning takes care of the fine tuning). Note, however, that you should only use the fast tuning in case the Iub reference signal is known to be a good one.
DN99580892
Id:0900d805809d5c0d Confidential
129
7652 BASE STATION NOTIFICATION
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
Otherwise the BTS frequency may be tuned into a totally incorrect value, causing serious problems in the network performance. Background information: The principle is that in the mobile network, the synchronization goes from MSC => RNC => BTS. But in reality that chain might be broken somewhere and, for example, when using leased lines, the BTS may take the reference synchronization from the transmission network of another operator. This does not harm the system if the synchronization of the leased line service provider is also accurate/stabile enough. The BTS uses the incoming synchronization signal as a reference for the Air interface, the accuracy requirement of which is set by 3GPP.
FAULT NAME
: Error in file server during file download type FAULT ID : 27: EFaultId_FileServerAl MEANING : The BTS is unable to obtain a file from the file server (error in FTP open or FTP get). The file server is down, the file is missing, or the path is incorrect. A possible error in the DCN and Iub, or a user administration error (an invalid username or password, or the user does not have access rights for the files). included in fault name is a variable parameter identifying the type of file for which the download failure has been reported. INSTRUCTIONS: 1.Check the file type according to the table below: - 1 - hwConfigurationFile 2 - configurationPlanFile 3 - logFile 4 - swFile 5 - licFile 6 - measurementFile 7 - rnwConfigurationPlanFile 11 - combinedSiteConfigurationPlanFile 12 - allConfigurationPlanFile 14 - testResultFile 15 - autoConfReport 17 - measurementPlanFile 18 - rnwMetadataFile 19 - topologyFile 22 - togglingParFile 23 - troubleShootingData 2. Retry the file update a few times. 3. Check the FTP account user settings. 4. Check the file and path names. 5. Check the administration log on the file server.
130
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7652 BASE STATION NOTIFICATION
FAULT NAME FAULT ID MEANING
: Extended logging level is active : 4143: EFaultId_ExtendedLoggingLevelActiveAl : This fault is generated for a notification that extended logging level is activated and may decrease the BTS performance. INSTRUCTIONS: Extended logging may decrease the performance of BTS. In critical case, disactivate extended logging categories with BTS Site Manager.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
FSM's sector based LCG is missing 4086: EFaultId_FsmSectorLcgMissing FSM does not have sector-based LCG commissioned to it. Re-commission the BTS with a correct number of sector-based LCGs so that every FSM has an LCG.
FAULT NAME FAULT ID MEANING
: Failure in optical RP3 interface : 3030: EFaultId_FailureInOptical_Rp3Interface : The BTS has detected an abnormal operation or a failure in an optical RP3 interface between two modules. The failure cannot be pointed to a specific module but there are several possible fault sources. INSTRUCTIONS: Note: Perform the steps below in the listed order until the alarm disappears. 1. Check the other active BTS alarms and act accordingly. 2. Check the cables between the System Module and RF Module/Extension System Module. Note that dirty optical connectors may cause the signal level to drop too low. 3. Depending on the alarm source, reset the RF Module, Extension System Module and/or System Module by blocking/unblocking it. 4. Replace the alarming module's Small Form Factor Pluggable (SFP). Check also the SFP in the other end and replace it, if needed. 5. Replace the alarming RF Module/Extension System Module. 6. If the System Module is the only alarming source or replacing the RF Module/Extension System Module does not clear the fault situation, replace the alarming System Module.
FAULT NAME FAULT ID MEANING
: Fan failure : 3050: EFaultId_FanFailure : All the fans or more than one in the same fan group are rotating slower or faster than required, are not rotating at all, or the RPM information is not available for the fans. The reason for this fault can be too low supply voltage or a broken fan. INSTRUCTIONS: Note: Perform the steps below in the listed order.
DN99580892
Id:0900d805809d5c0d Confidential
131
7652 BASE STATION NOTIFICATION
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
1. Make sure that the fan is not blocked. 2. Check the fan and cabling. 3. Replace the faulty fan module.
FAULT NAME FAULT ID MEANING
: Fan module faulty: : 1: EFaultId_FanPowerAl : UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: All the fans or more than one fan in the same fan group (WFA, WTR, WPA/WMP, WHX) are rotating more slowly than required, are not rotating at all, or the RPM information is not available for the fans. The reason for this fault is too low a supply voltage or a broken fan control board. The WFA, WFD, or WHX fan control module also controls the fans in the RF section (same sector). A failure in the RF section fans is reported from that WFA, WFD, or WHX, and the LED of the unit is stable red although it is working correctly. FlexiBTS: All the fans or more than one fan in the same fan group are rotating more slowly than required. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: 1. Check the Fan ID from the fault message and locate the problematic fan. See the Fan mapping figures in the Alarms and Troubleshooting document. 2. Check the fan and cabling. 3. If that does not help, replace the WFA, WFD, or MFU module. Or replace the fan controlled by the WFA, WFD, or MFU. Fan control: 'FAN UNIT' refers to a group of fans including the fan control unit. A 'fan' is a single blower. FlexiBTS:
1. Check the fans and connector. 2. Replace the fan module.
FAULT NAME FAULT ID MEANING
: Fan module operation degraded: : 0: EFaultId_ChangeFanAl : A fan does not rotate, rotates slower than required, or the RPM information is not available for the fan. INSTRUCTIONS: UltraSite, UltraSite/EUBB: 1. Check the fan ID from the fault message and locate the problematic fan. See the Fan mapping figures in the UltraSite and MetroSite WCDMA Base Station Faults document. 2. Check the fan and cabling. 3. If that does not help, replace the WFA, WFD, or MFU module. Or replace the fan controlled by the WFA, WFD, or
132
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7652 BASE STATION NOTIFICATION
MFU. Fan control: 'FAN UNIT' refers to a group of fans including the fan control unit. A 'fan' is a single blower. FlexiBTS: 1. Check the fan and connector. 2. Replace the fan module.
FAULT NAME FAULT ID MEANING
: Fan vendor not detected : 4073: EFaultId_FanVendorNotDetectedAl : Fan speed is too low for successful detection. Detection is tried again after Fan.Test.Timer expires. INSTRUCTIONS: 1. Check the fan and connector. 2. Replace the fan.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
File corrupted in SW download 28: EFaultId_SwPackageAl The download is corrupted or incorrectly formed SW. UltraSite, MetroSite, MetroSite 50, Triple-mode: 1. Retry the SW update. 2. Fetch the BTS log files and check the download status from the BTS SWDLreport. FlexiBTS, FlexiLiteBTS: 1. Retry the SW update. 2. Save the snapshot and check the download status from the BTS SWDLreport in the snapshot file.
FAULT NAME FAULT ID
: Filter unit operation failed : 1840: EFaultId_TuningFailureAl 1841: EFaultId_UnitFaultyAl 4043: EFaultId_TuningFrequencyOutOfRangeAl MEANING : A filter has not been able to tune on an appropriate sub-band properly (tuning failure), or another major failure has been detected by the filter (unit faulty). INSTRUCTIONS: In case of 4043:EFaultId_TuningFrequencyOutOfRangeAl: reconfigure the frequency settings. In case of 1840:EFaultId_TuningFailureAl, 1841:EFaultId_UnitFaultyAl: replace the filter unit.
FAULT NAME FAULT ID MEANING
: GPS Receiver alarm: EEPROM invalid : 4126: EFaultId_GpsReceiverEepromInvalidAl : GPS receiver has detected that one or more EEPROM segments were corrupt at reset, and its/their factory default settings need to be restored. INSTRUCTIONS: Perform the steps below in the listed order until the fault disappears. EEPROM invalid: 1. The GPS receiver has detected a malfunction in the
DN99580892
Id:0900d805809d5c0d Confidential
133
7652 BASE STATION NOTIFICATION
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
EEPROM memory of the GPS receiver. Perform a (remote) power reset for the GPS receiver. 2. There might be an HW fault in the GPS receiver. Check the operation and change the GPS module if needed.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
GPS Receiver alarm: no stored position 4124: EFaultId_GpsReceiverNoStoredPositionAl There is no accurate position stored in EEPROM. Perform the steps below in the listed order until the fault disappears. No stored position: 1. One of the GPS receiver settings is incorrect. Using the manager SW of the GPS receiver, set the receiver to store the position into non-volatile memory. If there is no tick mark in the position storage selection, the GPS receiver runs the site/self survey every time the GPS receiver is reset (either by manager command, power outage, or a GPS recovery reset). This means that if the GPS receiver installation quality is only average - and especially if the installation is a poor one - the GPS receiver turns the PPS reference OFF every now and then during the site survey. This means the BTS master clock drops to holdover mode much easier during the survey than during the normal operation.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
GPS Receiver alarm: not tracking satellites 4122: EFaultId_GpsReceiverNotTrackingSatellitesAl Poor GPS antenna installation. Perform the steps below in the listed order until the fault disappears. Not tracking satellites: 1. Definitely the most common reason for this fault indication is that the GPS antenna installation has not been done properly, that is the sky visibility is not good enough. See documentation for installations, and if there are discrepancies with the actual installation, re-install the GPS antenna. Note that even when the GPS antenna has a good sky visibility, the problem might be caused by installing the GPS antenna too close to the transmitter antenna(s) of the BTS, causing disturbances to the GPS receiver. 2. There might be a malfunction in the GPS receiver. Perform a (remote) power reset for the GPS receiver. 3. There might be a HW fault in the GPS receiver. Check the operation and change the GPS module if needed.
FAULT NAME FAULT ID
134
: GPS Receiver alarm: position questionable : 4125: EFaultId_GpsReceiverPositionQuestionableAl
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7652 BASE STATION NOTIFICATION
MEANING
: The receiver is used in a stored position, but then is moved to a new position. INSTRUCTIONS: Perform the steps below in the listed order until the fault disappears. Position questionable: 1. The GPS receiver has valid position data but it is not properly in line with the information estimated from the actual satellite visibility. The reason for this fault indication might be that the GPS antenna installation has not been done properly, that is the sky visibility is not good enough. Please refer the documentation for instructions and if there are deviations with the actual installation, re-install the GPS antenna. Please notice that even when the GPS antenna has a good sky visibility, the problem might be caused by installing the GPS antenna too close to the transmitter antenna(s) of the BTS, causing disturbancies for the GPS receiver. 2. There might be a malfunction in the GPS receiver. Perform a (remote) power reset for the GPS receiver. 3. There might be a HW fault in the GPS receiver. Check the operation and change the GPS module, if needed.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
GPS Receiver alarm: survey in progress 4123: EFaultId_GpsReceiverSurveyInProgressAl The GPS receiver is running a site/self survey. Perform the steps below in the listed order until the fault disappears. Survey in progress: 1. Do nothing. The alarm is informative only. Normally, the GPS receiver runs the survey for two reasons: a) somebody has started the survey manually; b) the GPS receiver has detected that the position has changed and the receiver has started an automatic survey. Note also that an automatic survey takes place every time during the first start-up. 2. If an automatic survey takes place every now and then, it might be an indication that the sky visibility is poor, and based on the poorly tracked satellites, the GPS receiver concludes that the position has changed. In this case, check activity of other faults (BTS fault history data), and if feasible, re-install the GPS antenna. 3. If the GPS installation is good but still an automatic survey takes place every now and then, there might be a malfunction in the GPS receiver. Perform a (remote) power
reset for the GPS receiver. 4. If the actions detailed in previous steps do not correct the situation, there might be an HW fault in the GPS receiver. Check the operation and change the GPS module if needed.
DN99580892
Id:0900d805809d5c0d Confidential
135
7652 BASE STATION NOTIFICATION
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
FAULT NAME FAULT ID MEANING
: GPS receiver alarm: control interface not available : 4011: EFaultId_GPSSystemElementAl : BTS has detected communication problem with the GPS receiver. INSTRUCTIONS: Perform the steps below in the listed order until the fault disappears. Control Interface not available: 1. The BTS has detected a malfunction in the control interface of the GPS receiver. Possible reason could be that BTS and GPS receiver do not support a common interface. Otherwise, perform a (remote) power reset for the GPS receiver. 2. Perform a (remote) BTS site reset for the whole BTS. 3. Perform a power reset for the whole BTS. 4. The cable between the GPS receiver and the BTS might work improperly. Make sure that the pins of the connectors (both ends of the cable) are free from oxide and other kind of dirt, meaning that the pin connection quality is good. 5. The cable between the GPS receiver and the BTS might be faulty. Check the situation and change the cable, if needed. 6. There might be an HW fault in the GPS receiver. Check the operation and change the GPS module, if needed. 7. There might be an HW fault in the BTS System Module. Check the operation and change the System Module, if needed.
FAULT NAME FAULT ID MEANING
: Heating element not working : 1860: EFaultId_HeatingMatNotWorkingAl : The heater control connection of the FSM is faulty, there is no heater or the heater is faulty. INSTRUCTIONS: 1. Check whether the heating element exists at all. 2. Check the heater control connection and that the heater is working. 3. Replace the alarming component.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
FAULT NAME FAULT ID MEANING
136
Incoherency in cell configuration 4000: EFaultId_IncoherencyInConfiguration Too many LCRs are commissioned to one RF Module. Recommission the BTS with a correct number of LCRs per RF Module.
: Incompatible SW version detected : 23: EFaultId_IncompatibleSwVersionAl 24: EFaultId_ObsoleteSwVersionAl : A new unit with incompatible SW has probably been inserted
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7652 BASE STATION NOTIFICATION
in the BTS. INSTRUCTIONS: Update compatible SW to the BTS (check the SW versions to see the active SW version, and update the active SW version), unless it is automatically updated by NetAct. NOTE: If also fault 10:EFaultId_NoConnectionToUnitAl is active on the source unit then SW update should be postponed until fault 10:EFaultId_NoConnectionToUnitAl is cancelled. Related BTS - AXC interface: check the SW version of the BTS and AXC, and update compatible SW to the AXC or BTS.
FAULT NAME FAULT ID MEANING
: Invalid configuration file : 4036: EFaultId_InvalidConfigurationFileAl : The commissioning file is missing, or an incorrect commissioning file has been detected during a BTS startup as follows: "Validation failed because of incompatible data" INSTRUCTIONS: 1. Check and correct the contents of the commissioning file. 2. Recommission the BTS with a valid commissioning file.
FAULT NAME FAULT ID
: MHA unit operation failure : 1869: EFaultId_MinorTMAFaultAl 1870: EFaultId_MajorTMAFaultAl MEANING : A fault in the Masthead Amplifier (MHA) is detected. The fault reduces the gain performance or completely prevents the function of the MHA. INSTRUCTIONS: 1. Check the MHA type and configuration settings of BTS. If the given MHA requires DC voltage on BTS2 (Diversity) port, perform ALD commissioning properly and reset BTS. 2. Replace the alarming module.
FAULT NAME FAULT ID MEANING
: Module not supported by current SW version : 4063: EFaultId_NotSupportedModuleMixAl : An unsupported module was detected in the System Module. Typically, this happens when the System Module SW in use does not support the module. INSTRUCTIONS: Replace the unsupported module or upgrade the System Module SW.
FAULT NAME FAULT ID MEANING
: No connection to WEA and unable to detect External alarms : 70: EFaultId_UnableToDetectEacAlarmsAl : The WEA unit is missing from the BTS or it cannot be detected. INSTRUCTIONS: 1. Check the WEA and cabling. See Troubleshooting instructions for how to check units behind the same bus. 2. If that does not help, replace the alarming unit.
DN99580892
Id:0900d805809d5c0d Confidential
137
7652 BASE STATION NOTIFICATION
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
FAULT NAME FAULT ID
: No connection to unit : 10: EFaultId_NoConnectionToUnitAl 4052: EFaultId_ConnectionToUnitLostAl MEANING : Connection to a unit that belongs to the BTS configuration has been lost or FSP cannot be detected. INSTRUCTIONS: FlexiBTS: 1. Make sure that the module is properly connected. If the module LED does not light up, the module is faulty. Check the alarming module. In case of two FSM-r3, check also SRIO cable connection between the system modules. 2. Check the fault history. FlexiLiteBTS: Check the fault history. UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: 1. Check the fault history, alarming unit and subrack. 2. If the SW has been updated recently, reload the SW. 3. If the WAF or WIC is alarming, try recommissioning the site. 4. Make sure that the unit is properly connected. If the unit LED does not light up, the unit is faulty. The fault might also be in the WPS unit or backplane. 5. Check the power cables, connectors, and the I2C bus cables. Cancel alarms: Removing and inserting the WIC, WSM or primary WAM causes a site reset. If both WSCs are removed, inserting the first removed WSC back into the cabinet causes a site reset. If the 7650 BASE STATION FAULTY alarm is issued, reset the site. First, try to reset the site with the software. If that does not help, replace the alarming unit. If the WSMF unit is not present (replaced by WSMB)in BTS, alarming WSPFs are not used and should be removed from BTS. WSPFs can be removed, because without a WSMF unit BTS works as UltraSite not as EUBB.
FAULT NAME FAULT ID MEANING
: No module fan detected : 1932: EFaultId_FrNoFansDetected : Radio Module cannot identify the used fan type, or the fan is not installed. INSTRUCTIONS: 1. Make sure that the fan connector is properly mounted. 2. If that does not help, replace the fan module.
FAULT NAME FAULT ID MEANING
138
: Non fatal ATM traffic overload : 305: EFaultId_CongestionAl : Traffic load is approaching the maximum capacity. However, no data is discarded yet.
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7652 BASE STATION NOTIFICATION
INSTRUCTIONS: Check that the ATM configurations in the BTS, AXC and RNC match.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
FAULT NAME FAULT ID MEANING
Not enough DSP capacity to set up a cell 124: EFaultId_NotEnoughWspCapasitySetupCellAl Not enough BTS baseband capacity to set up a cell. 1. Lock/unlock the cells. 2. Add more baseband capacity to BTS or replace the broken baseband unit, if that was the reason for the lack of capacity.
: Not enough resources for commissioned HSUPA : 130: EFaultId_MinimumNumberOfClusterFractionsUnavailableAl : There are not enough resources for the HSUPA minimum
capacity based on the commissioned parameters "Minimum Baseband Decoding Capacity" and "Minimum HSUPA Users". INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode: 1. Check the configuration to make sure that there are enough resources for the minimum HSUPA capacity. 2. If there are not enough resources, add the required number of WSP units, replace the broken ones, or re-commission the BTS and pre-reserve less capacity for the HSUPA. 3. Reset the BTS to get the minimum capacity preselection for the HSUPA in use. FlexiBTS and FlexiLiteBTS: 1. Check the configuration to make sure that there are enough resources for minimum HSUPA capacity. 2. If there are not enough resources, replace the broken module or re-commission the BTS and pre-reserve less capacity for HSUPA. 3. Reset the BTS to get the minimum capacity preselection for the HSUPA in use. UltraSite/EUBB: 1. Check the configuration to make sure that there are enough resources for minimum HSUPA capacity. 2. If there are not enough resources, replace the broken WSPF or re-commission the BTS and pre-reserve less capacity for HSUPA. 3. Reset the BTS to get the minimum capacity preselection for the HSUPA in use.
FAULT NAME FAULT ID MEANING
DN99580892
: OIC MCU Buffer Full : 2011: EFaultId_OIC_MCUBFullAl : The control message traffic between the modules is malfunctioning.
Id:0900d805809d5c0d Confidential
139
7652 BASE STATION NOTIFICATION
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
INSTRUCTIONS: Check the RF Module alarms.
FAULT NAME FAULT ID
: Oven oscillator clock missing : 903: EFaultId_OcxoClkMss 911: EFaultId_DualWscOcxoClkMss MEANING : The WSC is not able to deliver the clock signals required by the other units. INSTRUCTIONS: Replace the clock unit.
FAULT NAME FAULT ID
: Oven oscillator heating failure : 901: EFaultId_OcxoHeatingAl 912: EFaultId_DualWscOvAMss MEANING : The heating of oven oscillator fails and the unit is broken. The ambient temperature can also be too low or change too fast. INSTRUCTIONS: 1. Check the active fan alarms. 2. Replace the clock unit.
FAULT NAME FAULT ID MEANING
: PIC pool configuration failure : 154: EFaultId_PicPoolConfigurationFailureAl : Problem with PIC pool mapping due to UARFCN mismatch occured (UARFCN received from RNC is not compatible with UARFCN determined by BTSSM). Telecom checks if current PIC pool configuration in BTS (determined based on UARFCN delivered by BTSSM) is valid for UARFCN received from RNC during Cell Setup procedure. INSTRUCTIONS: When the fault is detected, operator should check UARFCN configuration. If PIC is required then UARFCN values should be changed in BTSSM.
FAULT NAME FAULT ID MEANING
: PPS reference missing : 1898: EFaultId_PpsRefMissAl : The reference clock monitoring has detected a loss of PPS signal in the reference received from the GPS receiver. INSTRUCTIONS: FlexiBTS: 1. Check the GPS receiver installation. 2. Check the GPS receiver status. 3. Check connection between the GPS receiver and FSM. FlexiLteBTS: 1. Check the GPS receiver installation. 2. Check the GPS receiver status. 3. Check connection between the GPS receiver and Flexi Lite BTS.
FAULT NAME FAULT ID
140
: Peer system module connection lost : 4110: EFaultId_PeerSystemModuleConnectionLostAl
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7652 BASE STATION NOTIFICATION
MEANING
: The master system module has lost optical connection to the peer system module. INSTRUCTIONS: Check the optical connection between master and peer system modules.
FAULT NAME
: Power on smodLogicalId pwrLineId line switched off remotely by user FAULT ID : 4107: EFaultId_RfPowerSwitchedOffFromBtsSmAl MEANING : Power feeding for the given Radio Module has been switched off by the user from BTS Site Manager remotely. INSTRUCTIONS: Enable power feeding towards Radio Module by switching RF power on in BTS Site Manager.
FAULT NAME FAULT ID
: RET antenna control failure : 1842: EFaultId_MotorJamAl 1843: EFaultId_ActuatorJamAl 1844: EFaultId_NotCalibratedAl 1845: EFaultId_NotConfiguredAl 1846: EFaultId_ActuatorInterferenceAl MEANING : Antenna tilting is not possible or might function incorrectly. INSTRUCTIONS: 1. Recalibrate the RET antenna. 2. If that does not help, replace the RET unit.
FAULT NAME FAULT ID MEANING
: RF Module failure : 3010: EFaultId_RfModuleFailure : The FlexiBTS has detected an abnormal operation or a failure in the internal functionality of the RF Module. INSTRUCTIONS: Note: Perform the steps below in the listed order until the alarm disappears. 1. Check the other active BTS alarms (System Module failure, Baseband Bus failure, Failure in optical RP3 interface and Antenna Line Device failure) and act accordingly. 2. Reset the alarming RF Module by blocking/unblocking it. 3. Check cables between the System Module and the RF Module. 4. If that does not help, replace the faulty RF Module.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
FAULT NAME FAULT ID
DN99580892
RF Module overvoltage protection faulty 1942: EFaultId_FrOverVoltageProtectionFaulty RF Module overvoltage protection is broken. Replace the alarming RF Module.
: RF loss of secondary optical interface : 1930: EFaultId_FRLossOfSecondaryOptIf
Id:0900d805809d5c0d Confidential
141
7652 BASE STATION NOTIFICATION
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
MEANING
: Secondary optical link between the System Module and the RF Module is lost. INSTRUCTIONS: 1. Check cables between the System Module and the RF Module. 2. Block/unblock the RF Module. 3. If that does not help, block/unblock the site. 4. If that does not help, replace the alarming RF Module.
FAULT NAME FAULT ID MEANING
: RF module temperature is high : 1941: EFaultId_FrOverTempAl : Validated module temperature is greater than the predefined value on unit property file. Relevant for Rel1 RF module only. INSTRUCTIONS: Check the fans and ensure that the ambient temperature on the site is is acceptable.
FAULT NAME FAULT ID MEANING
: RF sensor temperature too high in Flexi Lite : 4074: EFaultId_RfModuleTempTooHighInSbfAl : Validated sensor temperature is greater than the predefined property value in BTS Property File. Relevant for Flexi Lite RF part only. INSTRUCTIONS: Check the fans and ensure that the sensor temperature on the site is acceptable.
FAULT NAME FAULT ID MEANING
: Read-only field encountered in the antenna line device : 4140: EFaultId_ReadOnlyAl : An attempt to modify a field value in Antenna Line Device failed because the field is read-only. INSTRUCTIONS: No action required from the operator.
FAULT NAME FAULT ID MEANING
: Reading license targetID from BTS failed : 4023: EFaultId_FrParameterReadFailedAl : Failure occured during reading parameter from the Radio Module. INSTRUCTIONS: Note! Perform the steps below in the listed order until the alarm disappears. 1. Check the other active alarms. If the memory is corrupted, change the alarming module. 2. Reset the RF Module by blocking/unblocking it. 3. Replace the alarming module.
FAULT NAME FAULT ID MEANING
142
: Reduced receiver capacity in cell : 141: EFaultId_ReducedRachPreAmbleSignaturesAl : The RNC has requested a higher number of PRACH preamble signatures than the BTS can support for the requested cell range.
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7652 BASE STATION NOTIFICATION
INSTRUCTIONS: Commission a smaller amount of PRACH preamble signatures to the cell in the RNC and set up the cell again. This will trigger a new cell setup request for the BTS and the BTS cancels the fault, if the requested number of RACH preamble signatures is less or equal to the maximum number of supported RACH preamble signatures for the cell range in the BTS.
FAULT NAME
: Retrieving backup license targetId information from BTS failed FAULT ID : 4041: EFaultId_FrParameterMOExistenceCheckFailedAl MEANING : Retrieving the list of all parameters available in the Radio Module memory failed. The list is retrieved in order to check whether it contains the license targetId parameter. INSTRUCTIONS: Note: Perform the steps below in the listed order until the fault disappears. 1.Check the other active faults. If the memory is corrupted, replace the alarming module. 2. Reset the RF Module by blocking/unblocking it. 3. Replace the alarming module.
FAULT NAME FAULT ID MEANING
: Smoke alarm : 1310: EFaultId_SmokeAl : The internal smoke detector has detected smoke in the cabinet. INSTRUCTIONS: 1. Check the root cause. 2. If the alarm was false, replace the alarming smoke detector.
FAULT NAME FAULT ID
: System frame clock synchronization error in clock device : 5004: EFaultId_BofuSfclkErr 5007: EFaultId_BofuFrameSyncErr 5008: EFaultId_BofuSfnSigErr MEANING : The system frame alignment is lost or a parity error is detected in the incoming frame burst of BOFU FPGA. INSTRUCTIONS: 1. Reset BTS. 2. If resetting the BTS does not help, replace the WSMF.
FAULT NAME FAULT ID MEANING
: Temperature alarm : 3040: EFaultId_TemperatureAlarm : The internal temperature of the RF Module or System Module exceeds the threshold value, or the ambient temperature of the module(s) is beyond the specified limits. INSTRUCTIONS: Note: Perform the steps below in the listed order.
DN99580892
Id:0900d805809d5c0d Confidential
143
7652 BASE STATION NOTIFICATION
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
1. Check other BTS faults and act accordingly. 2. Check the ambient temperature of the BTS modules. If the ambient temperature is too high, make sure the airflow to the BTS modules is unobstructed, that is, the BTS modules are not covered with anything. If the ambient temperature is too low, it takes a while for the BTS modules to heat themselves to the threshold value. 3. Reset the alarming module/unit by blocking/unblocking it. 4. Replace the alarming module/unit.
FAULT NAME FAULT ID MEANING
: Unit not supported by current BTS SW version : 95: EFaultId_NotSupportedUnit : An unsupported unit has been detected in the BTS. Typically, this happens when a new unit version is installed and there is older BTS SW in use that does not support the new unit version. INSTRUCTIONS: FlexiBTS, UltraSite/EUBB:: 1. Upgrade the system module SW. 2. Replace the unit. FlexiLiteBTS: 1. Upgrade the Flexi Lite BTS software. 2. Replace the Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: Unit temperature is high : 2: EFaultId_UnitOverheatAl : The temperature of a unit/module exceeds the threshold value. INSTRUCTIONS: Check the active fan alarms, and the airflow of the BTS.
FAULT NAME FAULT ID MEANING
: User logging inactive : 4151: EFaultId_UserLoggingInactiveAl : User-configured logging is temporarily suspended because of high load situation in BTS. INSTRUCTIONS: If the situation keeps repeating, consider modifying of custom logging to less detailed log settings.
FAULT NAME FAULT ID
: WCI baseband reference clock failure : 1001: EFaultId_RedundantClkMss 1002: EFaultId_MasterClkMss MEANING : The master or redundant WSC does not generate Baseband Reference Clock (BRCLK) to the WCI because of an internal failure or a clock driver failure in the WSC unit. INSTRUCTIONS: 1. Block/unblock the active WSC unit. 2. Replace the WCI unit. 3. Replace both WSC units.
144
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7652 BASE STATION NOTIFICATION
FAULT NAME FAULT ID MEANING
: WEA power regulator fault : 1303: EFaultId_RegulatorAl : The WEA unit external interface connectors are connected incorrectly, or there is a shot circuit in the +5 VCD. INSTRUCTIONS: 1. Disconnect the external cables and check whether the alarm disappeares. 2. Check the external cables and connections. 3. If the alarm does not disappear, check the WEA and replace it if it is faulty.
FAULT NAME FAULT ID
: WIB unit battery failure : 1304: EFaultId_BatteryVoltageAl 1307: EFaultId_BatteryFailure 1308: EFaultId_CellBalanceAl MEANING : WIB unit battery failure: - Several battery blocks (cells) are dead and the back-up system is out of order. - Some of the battery blocks (cells) reached an overcharge or a discharge voltage in a stand-by condition. - The voltage of one cell is not compatible with the other cell voltages. INSTRUCTIONS: 1. Check the battery cablings and cells' voltage levels. 2. Replace the WIB unit or battery.
FAULT NAME FAULT ID MEANING
: WIB unit battery temperature out of range : 1306: EFaultId_BatteryTempAl : Because the heater or the heater control unit does not work correctly, the temperature measured inside the unit is out of the normal temperature range. INSTRUCTIONS: 1. Check the battery space's temperature. 2. Check the battery temperature sensor.
FAULT NAME FAULT ID MEANING
: WIB unit power back-up time alarm : 1305: EFaultId_BackupTimeAl : The WIB cannot supply nominal power for 10 seconds and/or the estimated battery life is 26 weeks or less. INSTRUCTIONS: Replace the WIB unit.
FAULT NAME FAULT ID MEANING
DN99580892
: WSC oven oscillator fault : 907: EFaultId_DualWscDacWordAlarm : The oven oscillator adjusting area is reaching its limit value. The alarm is activated if the WSC tunes the oven oscillator so that the DAC word (parameter to control the oven oscillator output frequency) value becomes lower than 205 or greater than 3891 (5 of the total adjustment area). The range for the DAC word is 0 - 4095. The cause of the
Id:0900d805809d5c0d Confidential
145
7652 BASE STATION NOTIFICATION
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
alarm can be: - The Iub reference frequency has been incorrect for a long time (up to several days) due to a fault in the transmission network synchronization (which in turn is caused by an equipment fault or a setting error). Before activating this alarm, the alarm 7652 BASE STATION NOTIFICATION: 'Difference between BTS master clock and reference frequency' may have been active. - If the BTS integrated transport part receives the synchronization information via the 2.048 MHz synchronization input (external clock source), the alarm situation may be caused by a fault in that signal. In that case, the alarm behavior notifications listed with the Iub signal (see above) are also valid in this case. - The fast tuning action of the BTS master clock may have been executed without checking if the reference signal is correct or not. If the reference signal is incorrect during the fast tuning execution, it may result in adjusting the BTS master clock frequency far from the nominal value, which causes serious problems in the network performance. - There is an equipment fault in the BTS. - Due to the oven oscillator (OCXO) aging inside the WSC unit, the unit may be approaching the end of its lifetime. In such case, after the alarm activation, the DAC value is quite stable, whereas in the other fault cases it may be very unstable or at the edge of the adjustment area (0 or 4095). Note that if the alarm 7651 BASE STATION OPERATION DEGRADED: 'WSC oven oscillator fault' becomes active, it may cause the alarm 7652 BASE STATION NOTIFICATION: 'Difference between BTS master clock and reference frequency' to cancel. INSTRUCTIONS: 1. In the case of a fault in the transmission network synchronization, you need to correct the network synchronization. The long-term accuracy of the Iub signal must be +/- 0.015 ppm or better. 2. In case of BTS equipment fault, the location may be: 2.1 Transport part - First check the alarms of the AXC node with AXC Manager and act accordingly. - If there are no alarms, check the AXC synchronization settings. 2.2 WSC unit - If both the Iub reference signal accuracy and the AXC node are in order but the WSC unit is still alarming, run the fast tuning procedure with BTS Site Manager. - If that does not solve the problem in a few minutes, reset the site. - If that does not help, replace the WSC unit. Note: In
146
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7652 BASE STATION NOTIFICATION
case the BTS is equipped with two WSCs, the redundant unit takes over the operation of the faulty unit. But if the fault situation is caused by an incorrect reference signal, both the WSC units may start alarming sooner or later. 3. After the fault situation has been cleared, the BTS master clock may also require tuning, because the BTS master clock adjustment is quite slow. You can perform the tuning: - manually, by changing the DAC word (during a site visit), or - with fast tuning, where the BTS master clock is tuned automatically in a few minutes near the Iub reference (normal tuning takes care of the fine tuning) Note, however, that the fast tuning should only be used in case the Iub reference signal is known to be a good one. Otherwise the BTS frequency may be tuned into a totally incorrect value, causing serious problems in the network performance. Background information: The principle is that in a mobile network, the synchronization goes from MSC > RNC > BTS. But in reality that chain might be broken somewhere and, for example, when using leased lines, the BTS may take the reference synchronization from the transmission network of another operator. This does not harm the system if also the synchronization of the leased line service provider is accurate/stable enough. The BTS uses the incoming synchronization signal as a reference for the Air interface, the accuracy requirement of which is set by 3GPP.
FAULT NAME FAULT ID MEANING
: WSC phase difference jammed to zero reading : 22: EFaultId_WscPhaseDiffJammedAl : The WSC phase measurement is jammed and the tuning operation is degraded. The problem can be caused by a WSC fault, or a too fast frequency change on the Iub. INSTRUCTIONS: 1.If the basic accuracy of the Iub signal is in order but there is too much instability, that is, the jitter/wander is outside the acceptable limits, the synchronization of the transmission network must be corrected. The limits for the jitter/wander are defined in the ITU-T G.823. No actions on the BTS are needed. 2. Reset the site and wait about 10 minutes. 3. Try a power-on reset. If the alarm reappears, replace the unit. If the alarm reappears during the next few weeks or the clock seems unstable, replace the unit. Background information: The principle in the mobile network is that the synchronization goes from MSC => RNC => BTS. But in reality that chain might be broken somewhere and,
DN99580892
Id:0900d805809d5c0d Confidential
147
7652 BASE STATION NOTIFICATION
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
for example, when using leased lines the BTS may take the reference synchronization from the transmission network of another operator. This does not harm the system if also the synchronization of the leased line service provider is accurate/stable enough. The BTS uses the incoming synchronization signal as a reference for the Air interface, the accuracy requirement of which is set by 3GPP.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
WSC switch unsuccessful 1823: EFaultId_ClkSwitchFailAl The WSC recovery switch over failed. 1. Fast tune the active unit. 2. Block/unblock the alarming unit. This may cause a BTS reset.
FAULT NAME FAULT ID MEANING
: WSM failure : 3001: EFaultId_EubbWsmAl : The BTS has detected an abnormal operation or a failure in the internal functionality of the WSMF unit. INSTRUCTIONS: Note: Perform the steps below in the listed order until the alarm disappears. 1. Check the alarm history, alarming unit and subrack. 2. Check that the unit is properly connected. If the unit LED does not light up, the unit is faulty. 3. Reset the BTS. 4. Replace the alarming unit.
FAULT NAME FAULT ID
: WSMA ST-Bus error : 1117: EFaultId_WsmStLeftParityErr2 1119: EFaultId_WsmStLeftSyncErr2 1121: EfaultId_WsmStRightParityErr2 1123: EfaultId_WsmStRightSyncErr2 MEANING : The TX signal is transported from the WSP unit to all WTR units via the WSMs. The WSM units in different subracks are connected to each other via the ST buses. This alarm is generated when the WSM unit detects errors in the incoming ST bus from the adjacent WSM unit. The reason for the failure is the cable between the WSM front panels or the WSM units indicated in the alarm. INSTRUCTIONS: 1. Run the WCDMA BTS loop test. 2. Check the WSM cables. 3. Replace the units indicated in the alarm one by one and check whether the problem is cleared (see Troubleshooting instructions).
FAULT NAME
148
: WSMA T-Bus error
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7652 BASE STATION NOTIFICATION
FAULT ID
: 1125: EFaultId_Wsp0ParityErr2 1127: EFaultId_Wsp0SyncErr2 1129: EFaultId_Wsp1ParityErr2 1131: EFaultId_Wsp1SyncErr2 1133: EFaultId_Wsp2ParityErr2 1135: EFaultId_Wsp2SyncErr2 1137: EFaultId_Wsp3ParityErr2 1139: EFaultId_Wsp3SyncErr2 1141: EFaultId_Wsp4ParityErr2 1143: EFaultId_Wsp4SyncErr2 1145: EFaultId_Wsp5ParityErr2 1147: EFaultId_Wsp5SyncErr2 1248: EFaultId_Wsp1TbusParityErr2 1249: EFaultId_Wsp0TbusParityErr2 1250: EFaultId_Wsp1TbusSyncErr2 1251: EFaultId_Wsp0TbusSyncErr2 MEANING : The signal is transported from the WSP unit to the WTR unit via the WSM/WMC. This alarm is generated when the WSM unit detects errors in the incoming T bus from the WSP unit. The reason for the failure is probably the WSP or WSM/WMC unit. The unit may have been installed incorrectly or the backplane cabling is faulty. INSTRUCTIONS: Replace the units indicated in the alarm one by one and check whether the problem is cleared (see Troubleshooting instructions).
FAULT NAME FAULT ID MEANING
: Waiting for RF connections : 1859: EFaultId_WaitingRfConnectionAl : The module has been configured as a master System Module, but no Radio Module is connected to it. INSTRUCTIONS: Add Radio Modules to the System Module if it is intended to be the master System Module.
FAULT NAME : Writing parameter to Radio Module failed FAULT ID : 4022: EFaultId_FrParameterWriteFailedAl MEANING : Failure occured when writing parameter to the Radio Module was requested. INSTRUCTIONS: Note! Perform the steps below in the listed order until the fault disappears. 1. Check the other active faults. If the memory is corrupted, change the alarming module. 2. Reset the RF Module by blocking/unblocking it. 3. Replace the alarming module.
DN99580892
Id:0900d805809d5c0d Confidential
149
7652 BASE STATION NOTIFICATION
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
150
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7653 CELL FAULTY
31 7653 CELL FAULTY Meaning A critical fault (or faults) has occurred in a unit/module (or units/modules) that belong to the sector indicated in the alarm. Check the reason for the fault from the supplementary text field of the alarm. The effect of the fault on the functioning of the network element depends on the fault description. For more information, see base station fault descriptions in WCDMA RAN and Flexi Direct System Libraries. Supplementary information fields 1
rack (cabinet) number
2
shelf number
3
slot
4
type of unit
5
unit number
6
subunit number For more information, see instructions on Alarm Structure. Instructions
Verify the configuration of a BTS by checking the commissioning, cabling and correct installation of the units/modules at the BTS. Make sure the environment does not cause the fault. Before a unit/module is replaced at the BTS, the site should be reset to recover from any temporary faults which might have caused the malfunctioning of the unit/module. When an active alarm is a 'Start' alarm, a site reset is required to cancel the alarm. If the site reset or module block/unblock does not help, replace the faulty unit/module (see the source of the alarm and instructions fields of the corresponding alarms). Below is the list of BTS fault(s) which might have caused this alarm in BTS WN 8.0 release. In case of earlier SW release and in case you need more detailed fault descriptions refer WCDMA RAN and Flexi Direct System Libraries. The BTS fault descriptions are also included in BTS SW release documentation. If that does not help, contact your
DN99580892
Id:0900d805809d5c0d Confidential
151
7653 CELL FAULTY
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
local Nokia Siemens Networks representative.
FAULT NAME FAULT ID MEANING
: AIR fatal alarm : 1515: EFaultId_FatalAl : ARIO has detected a Fatal level alarm. Some ARIO alarms can be canceled without a reset but most ARIO alarms require the WOU block/unblock to cancel. INSTRUCTIONS: 1. Check the WOU or WRUs. 2. Use the ARIO Local Management Tool and the Advanced Indoor Radio user documentation to diagnose the cause of the error.
FAULT NAME FAULT ID MEANING
: Antenna Line Device failure : 3100: EFaultId_AntennaLineFailure : The System Module or the device itself has detected an abnormal operation or a failure in the antenna line device. INSTRUCTIONS: Note: Perform the steps below in the listed order until the alarm disappears. 1. Check the antenna line and antenna line devices. Make sure that the antenna line connectors are in the right torque. 2. Reset the alarming RF module by blocking/unblocking it. 3. Replace the faulty parts and/or devices along the antenna line. 4. Replace the RF Module.
FAULT NAME FAULT ID MEANING
: Antenna line faulty : 4045: EFaultId_AntennaLineFaultyAl : An alarm message has been received from the antenna line. The antenna line is faulty. INSTRUCTIONS: 1. Check the antenna line and antenna line device that causes the alarm. 2. Fix or replace the faulty parts/devices.
FAULT NAME FAULT ID
: Antenna1 connection fault : 804: EFaultId_Ant1Al 809: EFaultId_Ant2Al 814: EFaultId_Ant3Al MEANING : The BIAS-T has detected that the reflected TX power from the antenna has increased. The antenna cable between the WAF and MHA is faulty or the antenna is faulty. The BIAS-T may be faulty. INSTRUCTIONS: 1. Check the bias-T and MHA commissioning. 2. Block/unblock the WAF unit (check if the alarm reappears after 5 minutes). 3. Check the antenna line (see Troubleshooting instructions).
152
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7653 CELL FAULTY
4. Check the PITA cable connection (RJ45). a. Check the voltage (see connector pins in Troubleshooting instructions). b. Check the right connection (see User Manual). c. Check by cross connecting RJ45 cables between other sectors.
FAULT NAME FAULT ID MEANING
: BB bus reception error (summing device) : 2016: EFaultId_Muksu_SMTimeOffAl : The master frame in the received baseband bus frame is not in the correct place related to the internally generated master frame pulse. Either the frame has been set in the wrong place (PI delay), or the data itself is in the wrong place. INSTRUCTIONS: FlexiBTS: 1. Check the cables between the Master System Module and RF Module/Extension System Module. 2. Replace the unit causing the fault (Master System Module, Extension System Module, RF Module, FBIA). UltraSite/EUBB: 1. Replace the unit causing the fault (WSPF, WSMF).
FAULT NAME
: BTS config error (All units in a cell must be freq) FAULT ID : 58: EFaultId_FrequencyBandConflictInCellAl MEANING : A unit with an incompatible frequency type has detected. All units in the cell must be of the frequency type. INSTRUCTIONS: Check the unit frequency types in the cell and incompatible unit with a compatible one.
of same
been same replace the
FAULT NAME FAULT ID MEANING
: BTS config error (Not enough HW for LCR) : 1868: EFaultId_NotEnoughHwForLcrAl : UltraSite, MetroSite, MetroSite 50, Triple-mode: A dual carrier WTR has been replaced with a single carrier WTR, and it cannot serve both cells commissioned to the WTR. FlexiBTS: A dual PA RF Module has been replaced with a single PA RF Module, and it cannot serve all cells commissioned to the RF Module. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode: Replace the single carrier WTR with a dual carrier WTR. FlexiBTS: Replace the single PA RF Module with a dual PA RF Module. Alternatively, recommission the BTS with fewer cells.
DN99580892
Id:0900d805809d5c0d Confidential
153
7653 CELL FAULTY
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
FAULT NAME FAULT ID MEANING
: BTS config error (WAF overload, 50W not in dualWPA config) : 61: EFaultId_WafTxConnectorOverloadAl : Two 50 W WPAs are coupled to one WAF, or one 50 W WPA and one 28 W WPA are coupled to one WAF. Only two 28 W WPAs can be coupled together to one WAF unit. INSTRUCTIONS: Replace the 50 W WPAs with the 28 W WPAs.
FAULT NAME FAULT ID MEANING
: BTS config error (WPA / WSMA version conflict in cell) : 68: EFaultId_WpaWsmaVersionConflictAl : A WPAI/WPAJ with two carriers and a WOC were detected in the combination with a WSMA. INSTRUCTIONS: Replace the WSMA with a WSMB. Or replace the WPAI and WPAJ with a WPAA/WPAB.
FAULT NAME FAULT ID MEANING
: BTS config error (WTR used as dual TRX behind WSMA) : 54: EFaultId_WtrbWsmaVersionConflictAl : A WTR/WSM conflict is detected. The incompatible WTR cannot operate with the WSMA when two TRXs are used. INSTRUCTIONS: Replace the incompatible unit or recommission the BTS (Reconfiguration commissioning) with only one TRX on.
FAULT NAME FAULT ID
: BTS file error : 1802: EFaultId_FileRequestFlashAl 1803: EFaultId_FileParsingFailedAl 1866: EFaultId_RulesMissingAl 1867: EFaultId_RulesParsingAl MEANING : UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: The BTS unit properties data is invalid or missing. FlexiBTS: The BTS module properties data or optical interface FPGA file is invalid or missing. The FSP MCU SW file is invalid or missing. FlexiLiteBTS: The BTS properties data or optical interface FPGA file is invalid or missing. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: 1. Download two different SW packages so that the faulty file is removed from the BTS. 2. Download the SW again. 3. If the fault still exists after 10 minutes, replace the alarming unit. FlexiBTS, FlexiLiteBTS: 1. Download two different SW packages so that the faulty file is removed from the BTS. 2. Download the SW again. 3. Replace the System Module.
154
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7653 CELL FAULTY
FAULT NAME FAULT ID MEANING
: BTS internal SW management problem : 3090: EFaultId_BtsInternalSwManagementProblem : A software update to a unit/module or subassembly has failed, or a corrupted SW file has been detected in the FLASH. INSTRUCTIONS: Note: Perform the steps below in the listed order. FlexiBTS: 1. Check other active BTS faults. If the ROM disk is corrupted, change the alarming module. 2. Reset the RF Module and/or FBIA and/or System Module, depending on the alarm source: a. Reset the RF Module by blocking/unblocking it. b. Reset the FBIA by blocking/unblocking it. c. Reset the System Module. 3. Update and activate the SW to the BTS. 4. Check the SW files. 5. Replace the alarming module/unit. UltraSite/EUBB: 1. Check other active BTS faults. If the ROM disk is corrupted, change the alarming unit. 2. Reset the alarming unit. 3. Update and activate the SW to the BTS. 4. Check the SW files. 5. Replace the alarming unit. FlexiLiteBTS: 1. Reset the and/or DSP and/or CC&T, depending on the alarm source. 2. Update and activate the SW to the BTS. 3. Check the SW files. 4. Replace the alarming Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: BTS reset required : 4001: EFaultId_BtsResetNeededAl : The BTS detected an Extension Module as a capacity enhancement. The BTS detected an RF Module that cannot be taken into use without the BTS reset. The RF Module type differs from the previous one. INSTRUCTIONS: Reset (block/unblock) the BTS.
FAULT NAME FAULT ID MEANING
: Baseband Bus failure : 3020: EFaultId_BaseBandBusFailure : The BTS has detected an abnormal operation or a failure in the BTS internal baseband bus. The failure cannot be pointed to a specific unit/module but there are several possible fault sources. INSTRUCTIONS: Note: Perform the steps below in the listed order.
DN99580892
Id:0900d805809d5c0d Confidential
155
7653 CELL FAULTY
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
FlexiBTS: 1. Check other active BTS alarms and act accordingly. 2. Check the cables between the System Module and RF Module/Extension System Module. 3. Reset the RF Module and/or System Module, depending on the alarm source: a. Reset the RF Module by blocking/unblocking it. b. Reset the Extension System Module by blocking/unblocking it. c. Reset the master System Module. 4. Replace the alarming RF Module/Extension System Module. 5. If the master System Module is the source or replacing the RF Module/Extension System Module does not clear the fault situation, replace the alarming master System Module. UltraSite/EUBB: 1. Check other active BTS alarms and act accordingly. 2. Reset the alarming unit. 3. Check the cables in backplane. 4. Replace the alarming unit. FlexiLiteBTS: 1. Check other active BTS faults and act accordingly. 2. Reset the BTS by blocking/unblocking it. 3. Replace the Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: Baseband bus configuration of was rejected : 1811: EFaultId_BbBus_ConfFailedAl : The baseband bus related configuration of was rejected by the HW, SW, DSP, or LTX. INSTRUCTIONS: Replace the alarming module. FlexiLiteBTS: Note! Perform the steps below in the listed order until the fault disappears: 1. Restart the BTS 2. Replace the FlexiLiteBTS unit
FAULT NAME FAULT ID MEANING
: Cell block rejected by RNC/Flexi Direct RNC : 96: EFaultId_InternalCellBlockedAl : The cell has been disabled due to BTS internal reasons, for example, if the RNC has rejected the normal cell blocking during the Intelligent Shutdown. INSTRUCTIONS: 1. Check the other active alarms. 2. Check the mains power supply.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
156
Cell blocked 49: EFaultId_CellBlockedAl The user has blocked the cell with BTS Site Manager. To cancel the alarm, unblock the cell.
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7653 CELL FAULTY
FAULT NAME FAULT ID MEANING
: Cell calibration failure : 117: EFaultId_InitCalibAl : TX power calibration failure: a CPICH setup failure, CPICH release failure, WTR power out of range failure, or general initial calibration failure. INSTRUCTIONS: 1. Check the commissioning (LCR cabling). 2. Block/unblock the alarming unit or the WPA connected to the alarming WTR. If there was an internal failure, the unit needs to be blocked/unblocked to initialize/configure it again. 3. Run the WCDMA BTS loop test with BTS Site Manager to check the WSM cabling. (Note! The loop test cannot be run if the cell is already blocked because of an alarm.) 4. Check the RF and WSM cabling (for example, in the case of an incorrect cabling). 5. If the reported severity is 7653 Cell faulty, replace the WTR, WPA, WSMs or WSP. If the reported severity is 7654 Cell operation degraded (most probably the WPA cannot deliver enough output power), replace the WPA.
FAULT NAME FAULT ID MEANING
: Cell power monitoring : 125: EFaultId_CellPowerAl : The WPA/Radio output power has dropped. There is a fault in the downlink transmission path. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: 1. Block/unblock the WPA. If there was an internal failure, the unit needs to be blocked/unblocked to get it initialized/configured again. 2. Block/unblock the WTR belonging to the same LCR. 3. Check the RF TX cabling. 4. The fault might be in the WTR or WPA. FlexiBTS: 1. Block/unblock the RF Module. If there was an internal failure or sticking in the unit SW, the module needs to be blocked/unblocked to get it initialized/configured again. 2. Check the RF Module. 3. Replace the alarming module. FlexiLiteBTS: 1. Block/unblock the BTS. 2. If this does not help, replace the module.
FAULT NAME FAULT ID MEANING
: Commissioned antenna configuration not supported by HW : 4060: EFaultId_CommissionedAntConfNotSupportedByHwAl : The configuration in the commissioning file is not supported by the RF Module. INSTRUCTIONS: Note! Perform the steps below in the listed order until the fault disappears.
DN99580892
Id:0900d805809d5c0d Confidential
157
7653 CELL FAULTY
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
1. Check that the antenna configuration defined in the commissioning file is correct. 2. Replace the Radio Module with one that supports the used antenna configuration type.
FAULT NAME FAULT ID MEANING
: Commissioning error: : 3060: EFaultId_CommissioningError : Some of the commissioning parameters are either missing or faulty. Or there is a mismatch between them. INSTRUCTIONS: Note: Perform the steps below in the listed order. 1. Check the commissioning parameters with the BTS Site Manager Commissioning Wizard. 2. Load the correct commissioning file to the BTS.
FAULT NAME FAULT ID MEANING
: Communication failure : 1806: EFaultId_CommunicationFailureAl : Communication with the application failed. The application has not replied to the message that has been sent/resent to it. INSTRUCTIONS: FlexiBTS: 1. Make sure that the unit/module is properly connected. If the unit/module LED does not light up, the unit/module is faulty. Check the alarming unit/module. 2. Check the fault history. FlexiLiteBTS: 1. If the Flexi Lite BTS LED does not light up, the BTS is faulty. Check the Flexi Lite BTS. 2. Check the fault history.
FAULT NAME : Configuration error: FAULT ID : 3070: EFaultId_ConfigurationError MEANING : There is an incompatibility problem in the BTS HW/SW versions or the HW/HW configuration. Another possibility is that there is a mismatch between the BTS configuration and the RNC/Flexi Direct RNC parameters. INSTRUCTIONS: Note: Perform the steps below in the listed order. 1. Check the installed HW/SW version compatibility and the HW compatibility with the current BTS configuration. 2. Check that the BTS cell parameters from the RNC/Flexi Direct RNC match the BTS HW configuration (for example frequency, power). 3. Check the RNC/Flexi Direct RNC BTS faults for the alarming local cell (LCR). 4. Recommission the BTS to ensure that all parameters are correctly configured.
158
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7653 CELL FAULTY
FAULT NAME FAULT ID MEANING
: Delayed cell shutdown alarm : 38: EFaultId_DelayedCellShutdownAl : BTS cells are disabled because the Battery backup alarm (ID=37) is active. INSTRUCTIONS: Check external Power Line conditions and make sure if there is external power provided to BTS.
FAULT NAME FAULT ID MEANING
: Distributed site support not enabled : 4076: EFaultId_DistributedSiteSupportNotEnabledAl : Long fiber between FSM and furthest FR detected but feature status in SCF is FALSE. - Fiber length 0.2km - 15km: (actDistributedSite15 = False) - Fiber length 15km - 40km: (actDistributedSite40 = False) INSTRUCTIONS: Perform the steps below in the listed order until the fault disappears: 1. Either activate the required license for 15/40km distributed site or switch to shorter fiber between FSM and FR. 2. Restart FSM.
FAULT NAME FAULT ID MEANING
: Failure in optical RP3 interface : 3030: EFaultId_FailureInOptical_Rp3Interface : The BTS has detected an abnormal operation or a failure in an optical RP3 interface between two modules. The failure cannot be pointed to a specific module but there are several possible fault sources. INSTRUCTIONS: Note: Perform the steps below in the listed order until the alarm disappears. 1. Check the other active BTS alarms and act accordingly. 2. Check the cables between the System Module and RF Module/Extension System Module. Note that dirty optical connectors may cause the signal level to drop too low. 3. Depending on the alarm source, reset the RF Module, Extension System Module and/or System Module by blocking/unblocking it. 4. Replace the alarming module's Small Form Factor Pluggable (SFP). Check also the SFP in the other end and replace it, if needed. 5. Replace the alarming RF Module/Extension System Module. 6. If the System Module is the only alarming source or replacing the RF Module/Extension System Module does not clear the fault situation, replace the alarming System Module.
FAULT NAME FAULT ID
DN99580892
: Filter unit operation failed : 1840: EFaultId_TuningFailureAl 1841: EFaultId_UnitFaultyAl
Id:0900d805809d5c0d Confidential
159
7653 CELL FAULTY
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
4043: EFaultId_TuningFrequencyOutOfRangeAl : A filter has not been able to tune on an appropriate sub-band properly (tuning failure), or another major failure has been detected by the filter (unit faulty). INSTRUCTIONS: In case of 4043:EFaultId_TuningFrequencyOutOfRangeAl: reconfigure the frequency settings. In case of 1840:EFaultId_TuningFailureAl, 1841:EFaultId_UnitFaultyAl: replace the filter unit. MEANING
FAULT NAME FAULT ID MEANING
: Frame clock missing : 1903: EFaultId_FrFrameClockMissing : The System Module clock reference differs from the RF Module clock. INSTRUCTIONS: 1. Check cables between the System Module and RF Module. 2. Block/unblock the RF Module. 3. If that does not help, block/unblock the site. 4. If that does not help, replace the faulty unit.
FAULT NAME FAULT ID MEANING
: Immediate cell shutdown alarm : 39: EFaultId_ImmediateCellShutdownAl : BTS cells are disabled because the Battery backup alarm (ID=37) is active. INSTRUCTIONS: Check external Power Line conditions and make sure if there is external power provided to BTS.
FAULT NAME FAULT ID MEANING
: Incoherency in cell configuration : 1856: EFaultId_IncoherencyInCellConfigurationAl : Both sector types (A and B) are configured to the same RF Module in the two-carrier case. INSTRUCTIONS: Recommission the LCRs in a way that only one sector type is used in one RF Module.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
Incoherency in cell configuration 4000: EFaultId_IncoherencyInConfiguration Too many LCRs are commissioned to one RF Module. Recommission the BTS with a correct number of LCRs per RF Module.
FAULT NAME FAULT ID MEANING
: Incoherency with RF Modules : 1857: EFaultId_IncoherencyWithRFModulesAl : Incorrect cell configuration for RF Modules with different frequency. The same cell is configured for two RF Modules which are not at the same frequency. INSTRUCTIONS: 1. Check which Radio Module is at the faulty frequency. 2. Replace the incompatible Radio Module.
160
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7653 CELL FAULTY
FAULT NAME FAULT ID
: Incompatible SW version detected : 23: EFaultId_IncompatibleSwVersionAl 24: EFaultId_ObsoleteSwVersionAl MEANING : A new unit with incompatible SW has probably been inserted in the BTS. INSTRUCTIONS: Update compatible SW to the BTS (check the SW versions to see the active SW version, and update the active SW version), unless it is automatically updated by NetAct. NOTE: If also fault 10:EFaultId_NoConnectionToUnitAl is active on the source unit then SW update should be postponed until fault 10:EFaultId_NoConnectionToUnitAl is cancelled. Related BTS - AXC interface: check the SW version of the BTS and AXC, and update compatible SW to the AXC or BTS.
FAULT NAME FAULT ID
: Incompatible unit detected : 83: EFaultId_WtraWsmaWspaNotSupportedInCabinetAl 91: EFaultId_WrongUnitTypeInCabinetAl MEANING : An unsupported unit (for example a WSMA, WTRA, WSPA, WMCM or WTRB) has been detected in the cabinet. INSTRUCTIONS: Replace the unsupported unit with a unit of the correct type.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
Incorrect Rx bandwidth 4137: EFaultId_IncorrectRxBandwidthAl Unsupported Rx carrier bandwidth has been assigned to LCR. Check if the assigned Rx carrier bandwidth is supported by the given RF module and change it if needed. BTS reset is needed to take the changed Rx carrier bandwidth into use and to clear the fault.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
Incorrect Tx bandwidth 4138: EFaultId_IncorrectTxBandwidthAl Unsupported Tx carrier bandwidth has been assigned to LCR. Check if the assigned Tx carrier bandwidth is supported by the given RF module and change it if needed. BTS reset is needed to take the changed Tx carrier bandwidth into use and to clear the fault.
FAULT NAME FAULT ID MEANING
: Incorrect carrier separation : 4139: EFaultId_IncorrectCarrierSeparationAl : Unsupported carrier separation in Dual-Cell configuration has been assigned. INSTRUCTIONS: Check if the assigned carrier separation is supported by the given RF module and change it if needed. BTS reset is needed to take the changed carrier separation
DN99580892
Id:0900d805809d5c0d Confidential
161
7653 CELL FAULTY
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
into use and to clear the fault.
FAULT NAME FAULT ID MEANING
: Invalid carrier in WTR : 127: EFaultId_InvalidCarrierInWtr : There was an attempt to set the WTR to a channel not supported by the WTR (on a different frequency band). INSTRUCTIONS: 1. Make sure that correct carrier numbers are in use in the RNC. 2. Commission the BTS with the correct WCDMA carrier values for the WTR.
FAULT NAME FAULT ID MEANING
: Invalid frequency channel for the BTS HW : 1807: EFaultId_InvalidFrequencyChannelForBTSHW : The requested channel in the cell setup is not acceptable for the BTS hardware, because of an incorrect frequency band and/or a carrier spacing and/or the number of carriers. INSTRUCTIONS: Check the RNC cell parameters against the BTS HW configuration. The cell frequency is out of the min/max limit of the HW, or the number of carriers for the HW type is exceeded, or the carrier spacing limit is exceeded. There are different type variations of the HW that might have limitations in the supported frequency range and bandwidth.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
Low noise amplifier failure 1839: EFaultId_LNAFailureAl The Filter has detected a malfunction in the LNA unit. Replace the alarming Radio module.
FAULT NAME FAULT ID MEANING
: Missing RP3-01 link : 4064: EFaultId_MissingRp301LinkAl : Not enough RP3-01 links connected between FSM and FR. Commissioned cells cannot be routed via existing RP3-01 links. INSTRUCTIONS: Note! Perform the steps below in the listed order. 1. Check if other BTS fault indications are active. 2. Check that all RP3-01 fiber links and SFP transceivers between system module and radio module are properly connected and working. Add missing parallel RP3-01 links. 3. Restart the Radio Module. 4. Restart the BTS.
FAULT NAME
162
: Missing secondary RP3-01 link
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7653 CELL FAULTY
FAULT ID MEANING
: 4111: EFaultId_MissingSecondaryRp3LinkAl : Secondary optical link break / hot removal detected during BTS runtime. INSTRUCTIONS: Note! Perform the steps below in the listed order. 1. Check whether other BTS fault indications are active. 2. Check that all RP3-01 fiber links and SFP transceivers between system module and radio module are properly connected and working. Replace the broken fiber link.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
Module Clock Faulty 1926: EFaultId_FrModuleClockFaulty The RF Module lost the lock to the incoming clock. 1. Check the cables between the System Module and RF Module. 2. Block/unblock the RF Module. 3. If that does not help, replace the alarming RF Module.
FAULT NAME FAULT ID MEANING
: No WSM resources : 82: EFaultId_NoPrimaryWsmInSubRackAl : There should be two WSM units in the subrack 1. The WSM2 must always be connected when the WSM1 is used. If there is no connection to the WSM2, this fault is generated for the WSM1. INSTRUCTIONS: Insert the WSM2.
FAULT NAME FAULT ID
: No connection to unit : 10: EFaultId_NoConnectionToUnitAl 4052: EFaultId_ConnectionToUnitLostAl MEANING : Connection to a unit that belongs to the BTS configuration has been lost or FSP cannot be detected. INSTRUCTIONS: FlexiBTS: 1. Make sure that the module is properly connected. If the module LED does not light up, the module is faulty. Check the alarming module. In case of two FSM-r3, check also SRIO cable connection between the system modules. 2. Check the fault history. FlexiLiteBTS: Check the fault history. UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: 1. Check the fault history, alarming unit and subrack. 2. If the SW has been updated recently, reload the SW. 3. If the WAF or WIC is alarming, try recommissioning the site. 4. Make sure that the unit is properly connected. If the unit LED does not light up, the unit is faulty. The fault might also be in the WPS unit or backplane. 5. Check the power cables, connectors, and the I2C bus
DN99580892
Id:0900d805809d5c0d Confidential
163
7653 CELL FAULTY
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
cables. Cancel alarms: Removing and inserting the WIC, WSM or primary WAM causes a site reset. If both WSCs are removed, inserting the first removed WSC back into the cabinet causes a site reset. If the 7650 BASE STATION FAULTY alarm is issued, reset the site. First, try to reset the site with the software. If that does not help, replace the alarming unit. If the WSMF unit is not present (replaced by WSMB)in BTS, alarming WSPFs are not used and should be removed from BTS. WSPFs can be removed, because without a WSMF unit BTS works as UltraSite not as EUBB.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
Not able to synchronize baseband bus with 1815: EFaultId_BbBus_SyncFailedAl The baseband bus synchronization towards failed. FlexiLite: Replace the alarming module/plug-in FSP. FlexiLiteBTS: Replace the Flexi Lite BTS.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
Not enough WAF resources in LCR 98: EFaultId_NotEnoughWafResourcesPerCellAl There are not enough WAF units in a cell. UltraSite, MetroSite and Triple-mode: 1. See the section No connection to unit in the troubleshooting instructions. 2. Increase the number of WAF units in the BTS. MetroSite 50: Change the WAF.
FAULT NAME FAULT ID
: Optical interface faulty : 2000: EFaultId_OIC_TxAl 2001: EFaultId_OIC_PresAl MEANING : The Small Form Factor Pluggable (SFP) malfunction has occured or the SFP module is not physically present (no electrical connection exists). The SFP is a part of the fibre cable package. INSTRUCTIONS: 1. Check that the SFP is properly connected. 2. Replace the SFP module.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
164
Post test failed 1925: EFaultId_FrPostTestFailed An RF Module power-on self-test failed at start-up. Replace the faulty unit.
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7653 CELL FAULTY
FAULT NAME FAULT ID MEANING
: R-bus error : 425: EFaultId_RbusError : UltraSite, MetroSite, MetroSite 50, Triple-mode: The bus between the WSP and WTR does not work. The R-bus errors are probably caused by a faulty WSM or WTR. FlexiBTS: Error in the FSP or in the connection between the FSP and FCM. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode: 1. If the WSM/WMC also generates an alarm from a WTR unit, check the WTR and WSM cable. 2. If there are no active WSM/WMC alarms, the reason for the alarm is a faulty WSM/WMC or WSP. 3. Run a WCDMA BTS loop test to locate the faulty unit. 4. If the WSP is faulty, block/unblock it. 5. Replace the faulty unit. FlexiBTS: 1. Check the cabling between the System Module and RF Module. 2. Check the active RF Module alarms and act accordingly. 3. Replace the faulty module (System Module).
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
RF BB bus configuration error 1905: EFaultId_FrRfBbBusConfigError The RF Module baseband bus is configured incorrectly. 1. Block/unblock the RF Module. 2. If that does not help, block/unblock the site. 3. If that does not help, replace the faulty unit.
FAULT NAME FAULT ID MEANING
: RF BB bus synchronization error : 1904: EFaultId_FrRfBbBusSynchError : The baseband bus between the System Module and the RF Module is out of synchronization. INSTRUCTIONS: Note: In case of old RF HW rel1, start directly from step 2. 1. Check cables between the System Module and the RF Module. 2. Block/unblock the RF Module. 3. If that does not help, block/unblock the site. 4. If that does not help, replace the faulty unit
FAULT NAME FAULT ID MEANING
: RF Module Filter input power missing : 1910: EFaultId_FrFilterInputPowerMissing : The RF Module filter has measured a TX power that is too low. INSTRUCTIONS: 1. Block/unblock the RF Module. 2. If that does not help, replace the alarming RF Module.
DN99580892
Id:0900d805809d5c0d Confidential
165
7653 CELL FAULTY
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
RF Module Overheat 1913: EFaultId_FrOverheat The RF Module temperature is too high. 1. Check the fans and ensure that the ambient temperature on the site is acceptable. 2. If that does not help, replace the faulty unit.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
RF Module blocked 1931: EFaultId_FrBlocked A shared (Medusa) FR is blocked. Unblock the alarming module.
FAULT NAME FAULT ID MEANING
: RF Module configuring failed : 1900: EFaultId_FrConfiguringFailed : The RF Module configuration failed because of a HW or SW fault. INSTRUCTIONS: Replace the alarming RF Module.
FAULT NAME FAULT ID MEANING
: RF Module critical file not found : 1901: EFaultId_FrCriticalFileNotFound : A critical configuration file is missing from the RF Module. INSTRUCTIONS: Replace the alarming RF Module.
FAULT NAME FAULT ID MEANING
: RF Module failure : 3010: EFaultId_RfModuleFailure : The FlexiBTS has detected an abnormal operation or a failure in the internal functionality of the RF Module. INSTRUCTIONS: Note: Perform the steps below in the listed order until the alarm disappears. 1. Check the other active BTS alarms (System Module failure, Baseband Bus failure, Failure in optical RP3 interface and Antenna Line Device failure) and act accordingly. 2. Reset the alarming RF Module by blocking/unblocking it. 3. Check cables between the System Module and the RF Module. 4. If that does not help, replace the faulty RF Module.
FAULT NAME FAULT ID MEANING
: RF Module out of order : 1912: EFaultId_FrOutOfOrder : The RF Module is out of order because of a software or hardware fault. INSTRUCTIONS: 1. Block/unblock the RF Module.
166
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7653 CELL FAULTY
2. If that does not help, replace the alarming RF Module.
FAULT NAME FAULT ID MEANING
: RF Module power output faulty : 1918: EFaultId_FrPowerOutputFault : The Power Supply has detected an overvoltage, undervoltage, or overcurrent in the RF Module. INSTRUCTIONS: 1. Block/unblock the RF Module. 2. If that does not help, replace the faulty unit.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
RX out of order 1911: EFaultId_FrRxOutOfOrder The RF Module RX RF synthesizer is not locked. FlexiBTS: 1. Block/unblock the RF Module. 2. If that does not help, replace the faulty unit. FlexiLiteBTS: 1. BTS reset. 2. If that does not help, replace the FlexiLiteBTS.
FAULT NAME FAULT ID MEANING
: Radio resources switched off : 4057: EfaultId_RfSwitchedOffAl : The TX carriers served by the affected antenna lines are disabled, which causes degradation of operation of the related cells or their deactivation. This reduces the power transmitted by the Power Amplifier in Radio Module for the sake of protecting the Power Amplifier against HW failure caused by operation under excessive VSWR value conditions (antenna line impedance mismatch). INSTRUCTIONS: 1. Check the antenna lines: antennas, antenna cables, connector torques, and antenna line devices. 2. Check the antenna line (TX-cable-antenna) impedance matching.
FAULT NAME FAULT ID MEANING
: Receiving failure in optical interface : 2002: EFaultId_OIC_RxAl : The incoming optical signal to the Small Form Factor Pluggable (SFP) is missing, too weak, or the fiber cable has been detached. The connection between the System Module and the RF Module (LTX, Antenna Filter, Antenna Line Device) or between the Master System Module and the Extension System Module is broken. That might concern primary or secondary link. INSTRUCTIONS: 1. Check the status of the module behind the faulty link (Power on, and so on). 2. Check the SFP from both ends (the System Module and the module behind the faulty link). The optical interface LED indicates the faulty SFP. Replace the SFP if it is faulty.
DN99580892
Id:0900d805809d5c0d Confidential
167
7653 CELL FAULTY
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
3. Clean the connectors, test the fiber cable, and replace it if faulty. 4. If the steps above do not help, replace the module behind the faulty link.
FAULT NAME
: Synchronization failure in Optical Interface FAULT ID : 2005: EFaultId_OIC_SyncChAl MEANING : The RP3 channel has lost the frame synchronization state that it had achieved. INSTRUCTIONS: Swap the alarming and working links and then check where the alarm is now reported. If the alarming link remains the same, replace the System Module. If the alarming link changes, replace the RF Module behind that link.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
TX out of order 1907: EFaultId_FrTxOutOfOrder The RF Module TX path is not usable. FlexiBTS: 1. Block/unblock the RF Module. 2. If that does not help, replace the faulty unit. FlexiLiteBTS: 1. Reset BTS. 2. If that does not help, replace the FlexiLiteBTS.
FAULT NAME FAULT ID MEANING
: TX output power measurement fault : 103: EFaultId_MeasurementAl : UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: The WTR or WPA/WMP/WOU output power measurement has failed. FlexiBTS: The RF Module output power measurement has failed. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: 1. Block/unblock the alarming unit. If there was an internal failure, the unit needs to be blocked/unblocked to get it initialized/configured again. 2. Check the units and the RF cabling between the WPA/WMP/WOU and WTR units. FlexiBTS: 1. Reset the alarming RF Module with the block/unblock function. If there was an internal failure or sticking in the unit SW, the Module needs to be blocked/unblocked to get it initialized/configured again. 2. Check the cables between the System Module and RF Module. 3. If that does not help, replace the faulty RF Module.
168
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7653 CELL FAULTY
FAULT NAME FAULT ID
: Telecom configuration failure : 109: EFaultId_TcomSlaveRegAl 110: EFaultId_UnitRnwConfigAl 111: EFaultId_TcomSlaveConfigAl 119: EFaultId_WspAllocationAl MEANING : Telecom slave configuration or registration failure. Unit RNW configuration failure. Telecom RNW reconfiguration failure. FlexiBTS: - FSP unit to FCM allocation failure - Faraday unit to FSP allocation failure Note that depending on the fault source, unit status might relate either to the state of particular carrier resource on FR module or FSP board on FCM, and may not be in line with the state of source HW unit. Or UltraSite, MetroSite, MetroSite 50, Triple-mode: WSP unit to WAM allocation failure. UltraSite/EUBB: Faraday unit to WSPF allocation failure. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: Block/unblock the alarming unit. If there was an internal
failure, the unit needs to be blocked/unblocked to get it initialized/configured again. UltraSite/EUBB: If the alarming unit is WSPF, block/unblock the EUBB subrack. FlexiBTS: If there was an internal failure, in the case of an FR, the module needs to be blocked/unblocked to get it initialized/configured again. FlexiBTS Rel2: If the alarming unit is FSPC, block/unblock the alarming module.
FAULT NAME FAULT ID MEANING
: Temperature alarm : 3040: EFaultId_TemperatureAlarm : The internal temperature of the RF Module or System Module exceeds the threshold value, or the ambient temperature of the module(s) is beyond the specified limits. INSTRUCTIONS: Note: Perform the steps below in the listed order. 1. Check other BTS faults and act accordingly. 2. Check the ambient temperature of the BTS modules. If the ambient temperature is too high, make sure the airflow to the BTS modules is unobstructed, that is, the BTS modules are not covered with anything. If the ambient temperature is too low, it takes a while for the BTS modules to heat themselves to the threshold value. 3. Reset the alarming module/unit by blocking/unblocking
DN99580892
Id:0900d805809d5c0d Confidential
169
7653 CELL FAULTY
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
it. 4. Replace the alarming module/unit.
FAULT NAME FAULT ID MEANING
: Temperature too low (heating ongoing) : 1922: EFaultId_FrTemperatureTooLow : During RF startup: the temperature inside the RF Module is too low. Heating of module is ongoing. Wait until the alarm is canceled. This might take up to 30 minutes. During RF runtime: the temperature inside the RF module is too low. A problem may occur. INSTRUCTIONS: During RF startup only: 1. Heating of module is ongoing. Wait until the alarm is canceled. This might take up to 30 minutes. 2. If that does not help, block/unblock the RF Module. 3. If that does not help, replace the alarming RF Module.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
Timeout, commissioned resource not ready 35: EFaultId_UnitIsNotInUse The faulty unit has not been configured or initialised. Recommission the site.
FAULT NAME FAULT ID MEANING
: Too many LCGs for HW to support : 4004: EFaultId_TooManyLCGForHwAl : There is not enough HW capacity to support the commissioned number of Local Cell Groups (LCG). INSTRUCTIONS: Re-commission the BTS with the correct number of LCGs.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
Too many carriers allocated for LPA 99: EFaultId_TooManyCarriersPerWpaAl Too many carriers have been allocated to the WPA/WMP. Remove the additional carrier in the Reconfiguration commissioning.
FAULT NAME FAULT ID MEANING
: Unit (module) dangerously overheating : 1937: EFaultId_FrDangerouslyOverheat : Validated sensor temperature is greater than or equal to the predefined value on unit property file. INSTRUCTIONS: 1. Check the fans and ensure that the ambient temperature on the site is acceptable. 2. If that does not help, replace the faulty unit.
FAULT NAME FAULT ID MEANING
170
: Unit SW download failed : 6: EFaultId_SwDownloadAl : Software update to a unit/subunit or module has failed. UltraSite, MetroSite: The fault can also be caused by
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7653 CELL FAULTY
disconnected CIF bus cables. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: 1. Download the BTS SW again. 2. If the alarming unit is WSP, block/unblock the WSP. 3. If the alarming unit is WAM or WPA, reset the BTS. 4. If that does not help, replace the alarming unit. FlexiBTS: 1. Download the BTS SW again. 2. FCM: Reset the BTS. 3. If Step 2 does not help, replace the alarming module. FlexiLiteBTS: 1. Download the BTS SW again. 2. Reset the BTS. 3. If Step 2 does not help, replace the Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: Unit blocked : 48: EFaultId_UnitBlockedAl : A unit is blocked with BTS Site Manager. The purpose of the fault is to avoid alarms that might be raised during the unit maintenance task. INSTRUCTIONS: To cancel the alarm, unblock the unit/module.
FAULT NAME FAULT ID
: Unit initialization failure : 12: EFaultId_TcomConfigAl 13: EFaultId_AtmConfigAl 15: EFaultId_InitializationAl 4040: EFaultId_InitFaultManAl MEANING : A unit/module or an IP address initialization has failed. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: 1. Block/unblock the alarming unit. 2. Check if the non-commissioned WAM is the Master WAM. If so, this causes the fault. Check the fault history to find out why the WAM switch-over occurred. 3. If the WAM is the fault source, check the RNC IP address in the commissioning file and modify the file if needed. If that does not help, perform a power-off reset. 4. If step 3 does not help, replace the alarming unit. FlexiBTS: 1. Block/unblock the alarming module. If that does not help, replace the alarming module. 2. If the FCM/FCT is the fault source, check the RNC IP address in the commissioning file and modify the file if needed. If that does not help, perform a power-off reset. 3. If Step 2 does not help, replace the alarming module. FlexiLiteBTS: 1. Block/unblock the alarming module. If that does not help, replace the alarming module.
DN99580892
Id:0900d805809d5c0d Confidential
171
7653 CELL FAULTY
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
2. If the SCR is the fault source, check the RNC IP address in the commissioning file and modify the file if needed. If that does not help, perform a power-off reset. 3. If Step 2 does not help, replace the alarming module.
FAULT NAME FAULT ID MEANING
: Unit not supported by current BTS SW version : 95: EFaultId_NotSupportedUnit : An unsupported unit has been detected in the BTS. Typically, this happens when a new unit version is installed and there is older BTS SW in use that does not support the new unit version. INSTRUCTIONS: FlexiBTS, UltraSite/EUBB:: 1. Upgrade the system module SW. 2. Replace the unit. FlexiLiteBTS: 1. Upgrade the Flexi Lite BTS software. 2. Replace the Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: Unknown HW resource : 94: EFaultId_UnknownUnitType : A unit cannot be identified by its product code or by its physical device address (object ID). INSTRUCTIONS: FlexiBTS: Replace the alarming unit/module. FlexiLiteBTS: Replace the Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: Unknown product code : 93: EFaultId_UnknownProductCode : A module cannot be identified by its product code but is known by its physical device address (object_ID). INSTRUCTIONS: UltraSite/EUBB: Replace the alarming module. FlexiBTS: Replace the alarming module. FlexiLiteBTS: Replace the Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: VSWR major alarm : 1837: EFaultId_VSWRMajorAl : VSWR value exceeds the defined level. The antenna line is mismatched or damaged. INSTRUCTIONS: 1. Check the antenna cables, connectors, antenna, and possible antenna line devices. 2. Check the antenna line (TX-cable-antenna) impedance matching.
FAULT NAME FAULT ID
172
: WAF low noise amplifier faulty : 800: EFaultId_Lna1Al 801: EFaultId_Lna2Al 805: EFaultId_Lna3Al
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7653 CELL FAULTY
806: EFaultId_Lna4Al 810: EFaultId_Lna5Al 811: EFaultId_Lna6Al MEANING : One of the two RX pre-amplifiers (one in the main branch and the other in the diversity branch) is faulty. The LED indicates the faulty unit. MetroSite 50: One, some, or all of the RX pre-amplifiers (max 6) are faulty. The LED indicates the faulty unit(s). INSTRUCTIONS: 1. Block/unblock the WAF unit. This is most likely a HW fault, but blocking/unblocking the unit ensures that before a site visit. 2. If that does not help, replace the alarming unit.
FAULT NAME FAULT ID MEANING
: WPA power level changed : 57: EFaultId_WpaPowerLevelChangedAl : The power level of a replaced WPA unit differs from the original WPA unit. INSTRUCTIONS: If the WPA is accidently changed to a different power level type of WPA, replace the WPA unit to the correct power level type of WPA.
FAULT NAME FAULT ID
: WSM RR-Bus error : 1189: EFaultId_Rr0_0ParityErr2 1191: EFaultId_Rr0_0SyncErr2 1193: EFaultId_Rr0_1ParityErr2 1195: EFaultId_Rr0_1SyncErr2 1197: EFaultId_Rr1_0ParityErr2 1199: EFaultId_Rr1_0SyncErr2 1201: EFaultId_Rr1_1ParityErr2 1203: EFaultId_Rr1_1SyncErr2 MEANING : The signal is transported from the WTR to the WSP via the WSM. This alarm is generated when the WSM/WMC unit detects errors in the incoming RR bus from the WTR unit. The reason for the failure is probably the WTR or WSM/WMC unit. The unit may have been installed incorrectly or the backplane cabling is faulty. INSTRUCTIONS: 1. Run the WCDMA BTS loop test. 2. Replace the units indicated in the alarm one by one and check whether the problem is cleared. 3. Check the backplane cables and connectors (see Troubleshooting instructions). Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
DN99580892
Id:0900d805809d5c0d Confidential
173
7654 CELL OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
32 7654 CELL OPERATION DEGRADED Meaning A major fault (or faults) has occurred in a unit/module (or units/modules) that belong to the sector indicated in the alarm. Check the reason for the fault from the supplementary text field of the alarm. The effect of the fault on the functioning of the network element depends on the fault description. For more information, see base station fault descriptions in WCDMA RAN and Flexi Direct System Libraries. Supplementary information fields 1
rack (cabinet) number
2
shelf number
3
slot
4
type of unit
5
unit number
6
subunit number For more information, see instructions on Alarm Structure. Instructions
Verify the configuration of a BTS by checking the commissioning, cabling and correct installation of the units/modules at the BTS. Make sure the environment does not cause the fault. Before a unit/module is replaced at the BTS, the site should be reset to recover from any temporary faults which might have caused the malfunctioning of the unit/module. When an active alarm is a 'Start' alarm, a site reset is required to cancel the alarm. If the site reset or module block/unblock does not help, replace the faulty unit/module (see the source of the alarm and instructions fields of the corresponding alarms). Below is the list of BTS fault(s) which might have caused this alarm in BTS WN 8.0 release. In case of earlier SW release and in case you need more detailed fault descriptions refer to WCDMA RAN and Flexi Direct System Libraries. The BTS fault descriptions are also included in BTS SW release documentation. If that does not help,
174
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7654 CELL OPERATION DEGRADED
contact your local Nokia Siemens Networks representative.
FAULT NAME
: 10b8b coding error in Optical Interface device FAULT ID : 2004: EFaultId_OIC_LVDSRecAl MEANING : The fiber cable has interference; the data becomes faulty. A physical connection failure between the optical interface and the summing function (caused by bad circuit joints, for example). INSTRUCTIONS: 1. Reset the RF Module behind the faulty optical interface by blocking/unblocking it. 2. If that does not clear the fault situation, replace the RF Module that is causing the alarm. 3. If the System Module is the only source causing the alarm, or replacing the RF Module does not clear the fault situation, replace the System Module that is causing the alarm.
FAULT NAME FAULT ID MEANING
: AIR major alarm : 1513: EFaultId_MajorAl : ARIO has detected a Major level alarm. Some ARIO alarms can be canceled without a reset but most ARIO alarms require the WOU block/unblock to cancel. INSTRUCTIONS: 1. Check the WOU or WRUs. 2. Use the ARIO Local Management Tool and the Advanced Indoor Radio user documentation to diagnose the cause of the error.
FAULT NAME FAULT ID MEANING
: AIR minor alarm : 1514: EFaultId_MinorAl : ARIO has detected a Minor level alarm. Some ARIO alarms can be canceled without a reset but most ARIO alarms require the WOU block/unblock to cancel. INSTRUCTIONS: Check the WOU or WRUs. Use the ARIO Local Management Tool and the Advanced Indoor Radio user documentation to diagnose the cause of the error.
FAULT NAME FAULT ID MEANING
: Antenna Line Device failure : 3100: EFaultId_AntennaLineFailure : The System Module or the device itself has detected an abnormal operation or a failure in the antenna line device. INSTRUCTIONS: Note: Perform the steps below in the listed order until the alarm disappears. 1. Check the antenna line and antenna line devices. Make sure that the antenna line connectors are in the right torque. 2. Reset the alarming RF module by blocking/unblocking it.
DN99580892
Id:0900d805809d5c0d Confidential
175
7654 CELL OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
3. Replace the faulty parts and/or devices along the antenna line. 4. Replace the RF Module.
FAULT NAME FAULT ID MEANING
: Antenna line device HW failure : 1847: EFaultId_HardwareErrorAl : A hardware failure detected by an Usually this is a permanent fault INSTRUCTIONS: 1. Block/unblock the Radio module to the antenna line devices. 2. If that does not help, replace
antenna line device. (the hardware is broken). to give a power-off reset the antenna line device.
FAULT NAME FAULT ID
: Antenna line device configuration failure : 1848: EFaultId_WorkingSoftwareMissingAl 1888: EFaultId_AlConfigurationFailureAl MEANING : An antenna line or antenna line device is not properly configured. INSTRUCTIONS: 1. Update the proper SW to the device. 2. Check/correct the antenna line configuration. 3. If that does not help, replace the antenna line device.
FAULT NAME FAULT ID MEANING
: Antenna line failure : 1836: EFaultId_ALOvercurrentAl : Radio Module (60W RRH) or Filter (all others) has detected overcurrent on the antenna line. The antenna line might be damaged (short circuit), or some antenna line device is causing overload. All antenna line devices powered by the antenna line are out of order. INSTRUCTIONS: 1. Check the antenna line and antenna line devices. Fix or replace the faulty parts/devices. 2. Alarm is canceled only at RF Module reset or BTS reset.
FAULT NAME FAULT ID MEANING
: Antenna line operation degraded : 4046: EFaultId_AntennaLineDegradedAl : An alarm message has been received from the antenna line device. The antenna line operation is degraded. INSTRUCTIONS: 1. Check the antenna line and antenna line device that causes the alarm. 2. Fix or replace the faulty parts/devices.
FAULT NAME FAULT ID
MEANING
176
: Antenna1 connection fault : 804: EFaultId_Ant1Al 809: EFaultId_Ant2Al 814: EFaultId_Ant3Al : The BIAS-T has detected that the reflected TX power from
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7654 CELL OPERATION DEGRADED
the antenna has increased. The antenna cable between the WAF and MHA is faulty or the antenna is faulty. The BIAS-T may be faulty. INSTRUCTIONS: 1. Check the bias-T and MHA commissioning. 2. Block/unblock the WAF unit (check if the alarm reappears after 5 minutes). 3. Check the antenna line (see Troubleshooting instructions). 4. Check the PITA cable connection (RJ45). a. Check the voltage (see connector pins in Troubleshooting instructions). b. Check the right connection (see User Manual). c. Check by cross connecting RJ45 cables between other sectors.
FAULT NAME
: BTS Config error (Different WTR variants cannot coexist in cell) FAULT ID : 56: EFaultId_WtraWtrbVersionConflictInCellAl MEANING : There are different WTR variants in the same cell. INSTRUCTIONS: Replace the conflicting WTR unit with a compatible unit.
FAULT NAME FAULT ID
: BTS SW download or activation failed : 29: EFaultId_FileCorruptionAl 30: EFaultId_SwUpdateAl MEANING : The SW update to the BTS has failed. The error can be caused by a unit reset during the SW update, a hardware problem in the unit or cabinet, or a corrupted flash file system. INSTRUCTIONS: FlexiBTS: 1. Retry the SW update. 2. If other flash memory-related faults are active for the alarming module at the same time, replace the alarming module. FlexiLiteBTS: 1. Retry the SW update. 2. If other flash memory-related faults are active for the Flexi Lite BTS at the same time, replace the Flexi Lite BTS.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
FAULT NAME FAULT ID
DN99580892
BTS config error (WSM missing from RF subrack) 62: EFaultId_NoWsmForWtrInSubrackAl There is no WSM in commissioned RF subrack. Add WSM capacity to the subrack.
: BTS config error (incorrect carrier candidates) : 1808: EFaultId_IncorrectCarrierCandidateAl 1864: EFaultId_BTSConfigErrorAl
Id:0900d805809d5c0d Confidential
177
7654 CELL OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
MEANING
: Carrier candidates are commissioned for each cell (not WTR/LTX specific). INSTRUCTIONS: Recommission (Reconfiguration commissioning) the BTS with the correct carrier candidate values.
FAULT NAME FAULT ID
: BTS file error : 1802: EFaultId_FileRequestFlashAl 1803: EFaultId_FileParsingFailedAl
1866: EFaultId_RulesMissingAl 1867: EFaultId_RulesParsingAl MEANING : UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: The BTS unit properties data is invalid or missing. FlexiBTS: The BTS module properties data or optical interface FPGA file is invalid or missing. The FSP MCU SW file is invalid or missing. FlexiLiteBTS: The BTS properties data or optical interface FPGA file is invalid or missing. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: 1. Download two different SW packages so that the faulty file is removed from the BTS. 2. Download the SW again. 3. If the fault still exists after 10 minutes, replace the alarming unit. FlexiBTS, FlexiLiteBTS: 1. Download two different SW packages so that the faulty file is removed from the BTS. 2. Download the SW again. 3. Replace the System Module.
FAULT NAME FAULT ID MEANING
: BTS internal SW management problem : 3090: EFaultId_BtsInternalSwManagementProblem : A software update to a unit/module or subassembly has failed, or a corrupted SW file has been detected in the FLASH. INSTRUCTIONS: Note: Perform the steps below in the listed order. FlexiBTS: 1. Check other active BTS faults. If the ROM disk is corrupted, change the alarming module. 2. Reset the RF Module and/or FBIA and/or System Module, depending on the alarm source: a. Reset the RF Module by blocking/unblocking it. b. Reset the FBIA by blocking/unblocking it. c. Reset the System Module. 3. Update and activate the SW to the BTS. 4. Check the SW files.
178
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7654 CELL OPERATION DEGRADED
5. Replace the alarming module/unit. UltraSite/EUBB: 1. Check other active BTS faults. If the ROM disk is corrupted, change the alarming unit. 2. Reset the alarming unit. 3. Update and activate the SW to the BTS. 4. Check the SW files. 5. Replace the alarming unit. FlexiLiteBTS: 1. Reset the and/or DSP and/or CC&T, depending on the alarm source. 2. Update and activate the SW to the BTS. 3. Check the SW files. 4. Replace the alarming Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: Baseband Bus failure : 3020: EFaultId_BaseBandBusFailure : The BTS has detected an abnormal operation or a failure in the BTS internal baseband bus. The failure cannot be pointed to a specific unit/module but there are several possible fault sources. INSTRUCTIONS: Note: Perform the steps below in the listed order. FlexiBTS: 1. Check other active BTS alarms and act accordingly. 2. Check the cables between the System Module and RF Module/Extension System Module. 3. Reset the RF Module and/or System Module, depending on the alarm source: a. Reset the RF Module by blocking/unblocking it. b. Reset the Extension System Module by blocking/unblocking it. c. Reset the master System Module. 4. Replace the alarming RF Module/Extension System Module. 5. If the master System Module is the source or replacing the RF Module/Extension System Module does not clear the fault situation, replace the alarming master System Module. UltraSite/EUBB: 1. Check other active BTS alarms and act accordingly. 2. Reset the alarming unit. 3. Check the cables in backplane. 4. Replace the alarming unit. FlexiLiteBTS: 1. Check other active BTS faults and act accordingly. 2. Reset the BTS by blocking/unblocking it. 3. Replace the Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
DN99580892
: Cell calibration failure : 117: EFaultId_InitCalibAl : TX power calibration failure: a CPICH setup failure, CPICH
Id:0900d805809d5c0d Confidential
179
7654 CELL OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
release failure, WTR power out of range failure, or general initial calibration failure. INSTRUCTIONS: 1. Check the commissioning (LCR cabling). 2. Block/unblock the alarming unit or the WPA connected to the alarming WTR. If there was an internal failure, the unit needs to be blocked/unblocked to initialize/configure it again. 3. Run the WCDMA BTS loop test with BTS Site Manager to check the WSM cabling. (Note! The loop test cannot be run if the cell is already blocked because of an alarm.) 4. Check the RF and WSM cabling (for example, in the case of an incorrect cabling). 5. If the reported severity is 7653 Cell faulty, replace the WTR, WPA, WSMs or WSP. If the reported severity is 7654 Cell operation degraded (most probably the WPA cannot deliver enough output power), replace the WPA.
FAULT NAME FAULT ID MEANING
: Cell power monitoring : 125: EFaultId_CellPowerAl : The WPA/Radio output power has dropped. There is a fault in the downlink transmission path. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: 1. Block/unblock the WPA. If there was an internal failure, the unit needs to be blocked/unblocked to get it initialized/configured again. 2. Block/unblock the WTR belonging to the same LCR. 3. Check the RF TX cabling. 4. The fault might be in the WTR or WPA. FlexiBTS: 1. Block/unblock the RF Module. If there was an internal failure or sticking in the unit SW, the module needs to be blocked/unblocked to get it initialized/configured again. 2. Check the RF Module. 3. Replace the alarming module. FlexiLiteBTS: 1. Block/unblock the BTS. 2. If this does not help, replace the module.
FAULT NAME FAULT ID MEANING
: Cell power parameter out of range : 126: EFaultId_CellPowerParameterOutOfRangeAl : The power values in the cell configuration data sent by the RNC are out of range. INSTRUCTIONS: Set the correct power values to the RNC.
FAULT NAME FAULT ID MEANING
180
: Commissioning error: : 3060: EFaultId_CommissioningError : Some of the commissioning parameters are either missing or
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7654 CELL OPERATION DEGRADED
faulty. Or there is a mismatch between them. INSTRUCTIONS: Note: Perform the steps below in the listed order. 1. Check the commissioning parameters with the BTS Site Manager Commissioning Wizard. 2. Load the correct commissioning file to the BTS.
FAULT NAME FAULT ID MEANING
: Communication failure : 1806: EFaultId_CommunicationFailureAl : Communication with the application failed. The application has not replied to the message that has been sent/resent to it. INSTRUCTIONS: FlexiBTS: 1. Make sure that the unit/module is properly connected. If the unit/module LED does not light up, the unit/module is faulty. Check the alarming unit/module. 2. Check the fault history. FlexiLiteBTS: 1. If the Flexi Lite BTS LED does not light up, the BTS is faulty. Check the Flexi Lite BTS. 2. Check the fault history.
FAULT NAME FAULT ID MEANING
: Configuration error: : 3070: EFaultId_ConfigurationError : There is an incompatibility problem in the BTS HW/SW versions or the HW/HW configuration. Another possibility is that there is a mismatch between the BTS configuration and the RNC/Flexi Direct RNC parameters. INSTRUCTIONS: Note: Perform the steps below in the listed order. 1. Check the installed HW/SW version compatibility and the HW compatibility with the current BTS configuration. 2. Check that the BTS cell parameters from the RNC/Flexi Direct RNC match the BTS HW configuration (for example frequency, power). 3. Check the RNC/Flexi Direct RNC BTS faults for the alarming local cell (LCR). 4. Recommission the BTS to ensure that all parameters are correctly configured.
FAULT NAME FAULT ID MEANING
: Configuration file corrupted : 1924: EFaultId_FrConfigurationFileCorrupted : The RF Module SW detected conflicting or corrupted configuration data. INSTRUCTIONS: 1. Block/unblock the RF Module 2. If that does not help, replace the alarming RF Module.
DN99580892
Id:0900d805809d5c0d Confidential
181
7654 CELL OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
FAULT NAME FAULT ID
: Diversity antenna line fault : 803: EFaultId_Mha2Al 808: EFaultId_Mha4Al 813: EFaultId_Mha6Al MEANING : The operating voltage of the Mast Head Amplifier (MHA) is supplied through the BIAS-T from the WAF. The WAF monitors the consumption of the current and generates an alarm if it deviates from normal. The cable between the MHA and WAF is faulty, the Bias-T is faulty, the MHA is faulty, another antenna line device between the MHA and WAF is faulty, or the MHA does not exist. INSTRUCTIONS: 1. Check the MHA commissioning parameters. 2. Block/unblock the related WAF. 3. Check the RF cabling and Bias-T. 4. The fault can be in the WAF, Bias-T or MHA (see Troubleshooting instructions).
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
FPGA SW update failed 1928: EFaultId_FrFpgaSwUpdateFailed The FPGA software update has failed. 1. Block/unblock the RF Module. 2. If that does not help, replace the alarming RF Module.
FAULT NAME FAULT ID MEANING
: Failure in optical RP3 interface : 3030: EFaultId_FailureInOptical_Rp3Interface : The BTS has detected an abnormal operation or a failure in an optical RP3 interface between two modules. The failure cannot be pointed to a specific module but there are several possible fault sources. INSTRUCTIONS: Note: Perform the steps below in the listed order until the alarm disappears. 1. Check the other active BTS alarms and act accordingly. 2. Check the cables between the System Module and RF Module/Extension System Module. Note that dirty optical connectors may cause the signal level to drop too low. 3. Depending on the alarm source, reset the RF Module, Extension System Module and/or System Module by blocking/unblocking it. 4. Replace the alarming module's Small Form Factor Pluggable (SFP). Check also the SFP in the other end and replace it, if needed. 5. Replace the alarming RF Module/Extension System Module. 6. If the System Module is the only alarming source or replacing the RF Module/Extension System Module does not clear the fault situation, replace the alarming System Module.
FAULT NAME
182
: Filter unit operation failed
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7654 CELL OPERATION DEGRADED
FAULT ID
: 1840: EFaultId_TuningFailureAl 1841: EFaultId_UnitFaultyAl 4043: EFaultId_TuningFrequencyOutOfRangeAl MEANING : A filter has not been able to tune on an appropriate sub-band properly (tuning failure), or another major failure has been detected by the filter (unit faulty). INSTRUCTIONS: In case of 4043:EFaultId_TuningFrequencyOutOfRangeAl: reconfigure the frequency settings. In case of 1840:EFaultId_TuningFailureAl, 1841:EFaultId_UnitFaultyAl: replace the filter unit.
FAULT NAME FAULT ID
: Flash operation failure : 214: EFaultId_FlashWrAl 215: EFaultId_FlashRdAl 216: EFaultId_FlashEraseAl 217: EFaultId_FlashDrvAl 218: EFaultId_FlashDbChksumAl MEANING : A flash memory operation failure. If this fault continuously appears, the flash chip may be broken. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: 1. Check the other active faults. If the /rom-disk is corrupted, change the alarming unit. 2. Block/unblock the alarming unit. There are no recovery actions and because of that the block/unblock can be attempted once. If that does not help, replace the alarming unit. FlexiBTS, FlexiLiteBTS: 1. Check the other active faults. If the /rom-disk is corrupted, change the alarming unit/module. 2. Block/unblock the alarming unit/module. There are no recovery actions and blocking/unblocking can be attempted once. If that does not help, replace the alarming unit/module.
FAULT NAME FAULT ID MEANING
: Frame clock missing : 1903: EFaultId_FrFrameClockMissing : The System Module clock reference differs from the RF Module clock. INSTRUCTIONS: 1. Check cables between the System Module and RF Module. 2. Block/unblock the RF Module. 3. If that does not help, block/unblock the site. 4. If that does not help, replace the faulty unit.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
DN99580892
Gain adjust alarm 118: EFaultId_GainAdjustAl The WTR cannot adjust the TX output power. 1. Block/unblock the WTR. The unit needs to be
Id:0900d805809d5c0d Confidential
183
7654 CELL OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
blocked/unblocked to get it initialised/configured again if there was an internal failure. 2. Check the WTR RF TX cabling. 3. If that does not help, replace the alarming unit.
FAULT NAME FAULT ID
: Incompatible SW version detected : 23: EFaultId_IncompatibleSwVersionAl 24: EFaultId_ObsoleteSwVersionAl MEANING : A new unit with incompatible SW has probably been inserted in the BTS. INSTRUCTIONS: Update compatible SW to the BTS (check the SW versions to see the active SW version, and update the active SW version), unless it is automatically updated by NetAct. NOTE: If also fault 10:EFaultId_NoConnectionToUnitAl is active on the source unit then SW update should be postponed until fault 10:EFaultId_NoConnectionToUnitAl is cancelled. Related BTS - AXC interface: check the SW version of the BTS and AXC, and update compatible SW to the AXC or BTS.
FAULT NAME
: Increased BER detected on the optical connection to Radio Module FAULT ID : 1955: EFaultId_IncrBerOnRp3 MEANING : Increased bit error rate has been detected on the optical link to radio module which results in LCV errors in downlink baseband processing. INSTRUCTIONS: Note! Perform the steps below in the listed order until the fault disappears: 1. Check the optical connection between system module and FR module. Check SFP module(s) and/or re-adjust optical connectors and verify operation of any devices in the optical network between FSM and FRM, if such devices are in use. 2. Block/unblock the FR module. 3. If that does not help, replace the SFP module(s) in which the malfunctioning optical connection is terminated and/or replace the fiber.
FAULT NAME
: Initial calibration not started because other cell not cleared FAULT ID : 120: EFaultId_InitCalibNotStartedAl MEANING : There is a shared WPA/WMP in the configuration (the WPA serves two cells). The first cell needs to be calibrated and therefore the second active cell needs to be cleared, but the clearing fails. INSTRUCTIONS: 1. Block/unblock the WPA/WMP unit belonging to the same LCR as the alarming WTR. The unit needs to be blocked/unblocked to get it initialized/configured again if there was an
184
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7654 CELL OPERATION DEGRADED
internal failure. 2. Reset the site.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
Low noise amplifier failure 1839: EFaultId_LNAFailureAl The Filter has detected a malfunction in the LNA unit. Replace the alarming Radio module.
FAULT NAME FAULT ID
: MHA unit operation failure : 1869: EFaultId_MinorTMAFaultAl 1870: EFaultId_MajorTMAFaultAl MEANING : A fault in the Masthead Amplifier (MHA) is detected. The fault reduces the gain performance or completely prevents the function of the MHA. INSTRUCTIONS: 1. Check the MHA type and configuration settings of BTS. If the given MHA requires DC voltage on BTS2 (Diversity) port, perform ALD commissioning properly and reset BTS. 2. Replace the alarming module.
FAULT NAME FAULT ID
: Main antenna line fault : 802: EFaultId_Mha1Al 807: EFaultId_Mha3Al 812: EFaultId_Mha5Al MEANING : The operating voltage of the MHA is supplied through the Bias-T from the WAF. The WAF monitors the consumption of the current and generates an alarm if the consumption deviates from normal. The cable between the MHA and WAF is faulty, the Bias-T is faulty, the MHA is faulty, another antenna line device between the MHA and WAF is faulty, or the MHA does not exist. INSTRUCTIONS: 1. Check the MHA commissioning parameters. 2. Block/unblock the related WAF. 3. Check the RF cabling and Bias-T. 4. The fault can be in the WAF, Bias-T or MHA (see Troubleshooting instructions).
FAULT NAME FAULT ID MEANING
DN99580892
: Mast Head Amplifier above current window fault, : 1834: EFaultId_AboveCurrentWindowAl : The Masthead Amplifier (MHA) does not work properly. The received RF signal level is decreased. If both stages of the LNA on the uplink path fail, the MHA swithes the LNA to the by-pass mode. In the by-pass mode, the MHA has no gain but some loss. If only one stage of the LNA fails, the MHA still has about a half of its normal gain. With an integrated MHA, the fault may affect both
Id:0900d805809d5c0d Confidential
185
7654 CELL OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
main and diversity branches or just either of them. INSTRUCTIONS: 1. Check the antenna cables and connectors towards the MHA. Fix or replace the broken parts. 2. Restart the MHA by blocking and unblocking the Flexi Radio (FR) Module. Note! This operation affects all the antenna lines and cells related to the FR Module, not just the faulty one. If the alarm re-appears, replace the alarming module.
FAULT NAME FAULT ID MEANING
: Mast Head Amplifier below current window fault, : 1835: EFaultId_BelowCurrentWindowAl : The Masthead Amplifier (MHA) does not work properly. The received RF signal level is decreased. If both stages of the LNA on the uplink path fail, the MHA switches the LNA to the by-pass mode. In the by-pass mode, the MHA has no gain but some loss. If only one stage of the LNA fails, the MHA still has about a half of its normal gain. With an integrated MHA, the fault may affect both main and diversity branches or either of them. INSTRUCTIONS: 1. Check the antenna cables and connectors towards the MHA. Fix or replace the broken parts. 2. Restart the MHA by blocking and unblocking the Flexi Radio (FR) Module. Note! This operation affects all the antenna lines and cells related to the FR Module, not just the faulty one. If the alarm re-appears, replace the alarming module.
FAULT NAME FAULT ID MEANING
: Missing RP3-01 link : 4064: EFaultId_MissingRp301LinkAl : Not enough RP3-01 links connected between FSM and FR. Commissioned cells cannot be routed via existing RP3-01 links. INSTRUCTIONS: Note! Perform the steps below in the listed order. 1. Check if other BTS fault indications are active. 2. Check that all RP3-01 fiber links and SFP transceivers between system module and radio module are properly connected and working. Add missing parallel RP3-01 links. 3. Restart the Radio Module. 4. Restart the BTS.
FAULT NAME FAULT ID MEANING
: Missing secondary RP3-01 link : 4111: EFaultId_MissingSecondaryRp3LinkAl : Secondary optical link break / hot removal detected during BTS runtime. INSTRUCTIONS: Note! Perform the steps below in the listed order. 1. Check whether other BTS fault indications are active. 2. Check that all RP3-01 fiber links and SFP transceivers between system module and radio module are properly
186
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7654 CELL OPERATION DEGRADED
connected and working. Replace the broken fiber link.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
Module Clock Faulty 1926: EFaultId_FrModuleClockFaulty The RF Module lost the lock to the incoming clock. 1. Check the cables between the System Module and RF Module. 2. Block/unblock the RF Module. 3. If that does not help, replace the alarming RF Module.
FAULT NAME FAULT ID
: No connection to unit : 10: EFaultId_NoConnectionToUnitAl 4052: EFaultId_ConnectionToUnitLostAl MEANING : Connection to a unit that belongs to the BTS configuration has been lost or FSP cannot be detected. INSTRUCTIONS: FlexiBTS: 1. Make sure that the module is properly connected. If the module LED does not light up, the module is faulty. Check the alarming module. In case of two FSM-r3, check also SRIO cable connection between the system modules. 2. Check the fault history. FlexiLiteBTS: Check the fault history. UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: 1. Check the fault history, alarming unit and subrack. 2. If the SW has been updated recently, reload the SW. 3. If the WAF or WIC is alarming, try recommissioning the site. 4. Make sure that the unit is properly connected. If the unit LED does not light up, the unit is faulty. The fault might also be in the WPS unit or backplane. 5. Check the power cables, connectors, and the I2C bus cables. Cancel alarms: Removing and inserting the WIC, WSM or primary WAM causes a site reset. If both WSCs are removed, inserting the first removed WSC back into the cabinet causes a site reset. If the 7650 BASE STATION FAULTY alarm is issued, reset the site. First, try to reset the site with the software. If that does not help, replace the alarming unit. If the WSMF unit is not present (replaced by WSMB)in BTS, alarming WSPFs are not used and should be removed from BTS. WSPFs can be removed, because without a WSMF unit BTS works as UltraSite not as EUBB.
FAULT NAME FAULT ID
DN99580892
: No feedback signal : 1920: EFaultId_FrNoFeedBackSignal
Id:0900d805809d5c0d Confidential
187
7654 CELL OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
MEANING
: The feedback signal to predistortion is too weak or missing. The TX performance is degraded. INSTRUCTIONS: 1. Block/unblock the RF Module. 2. If that does not help, replace the alarming RF Module.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
Not enough WAF resources in LCR 98: EFaultId_NotEnoughWafResourcesPerCellAl There are not enough WAF units in a cell. UltraSite, MetroSite and Triple-mode: 1. See the section No connection to unit in the troubleshooting instructions. 2. Increase the number of WAF units in the BTS. MetroSite 50: Change the WAF.
FAULT NAME FAULT ID MEANING
: Optical interface buffer alarm : 2051: EFaultId_Muksu_BufferAl : RP3 or Ethernet buffering is not working and the buffer becomes full. The optical device malfunctions. The fault may be generated because of synchronization problems or incorrect initialization. INSTRUCTIONS: 1. Depending on the interface, reset the connected module/unit behind the interface that causes the alarm by blocking/unblocking it. 2. If that does not clear the fault situation, replace the connected module/unit behind the interface causing the alarm. FlexiBTS: 3. If the System Module is the only alarm source, or replacing the RF Module/Extension System Module does not clear the fault situation, replace the System Module causing the alarm. UltraSite/EUBB: 3. If WSMF is the only alarm source, or replacing the connected module/unit does not clear the fault situation, replace the WSMF that causes the alarm.
FAULT NAME FAULT ID
MEANING
188
: Optical interface data/control/Ethernet buffer full : 2006: EFaultId_OIC_DBRxFullAl 2007: EFaultId_OIC_DBTxFullAl 2008: EFaultId_OIC_CBRxFullAl 2009: EFaultId_OIC_CBTxFullAl 2010: EFaultId_OIC_EBFullAl : The RP3 or Ethernet buffering is not working and the buffer becomes full. The optical device is malfunctioning. The fault might be generated because of synchronization
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7654 CELL OPERATION DEGRADED
problems or incorrect initialization. INSTRUCTIONS: Swap the alarming and working links. Then check where the alarm is reported. If the alarming link remains the same, replace the System Module. If the alarming link changes, replace the RF Module behind that link.
FAULT NAME FAULT ID
: Optical interface faulty : 2000: EFaultId_OIC_TxAl 2001: EFaultId_OIC_PresAl MEANING : The Small Form Factor Pluggable (SFP) malfunction has occured or the SFP module is not physically present (no electrical connection exists). The SFP is a part of the fibre cable package. INSTRUCTIONS: 1. Check that the SFP is properly connected. 2. Replace the SFP module.
FAULT NAME FAULT ID MEANING
: Pipe dangerously overheating : 1938: EFaultId_FrPipeOverheat : Validated temperature of any PA sensor is greater than or equal to the predefined value on unit property file. INSTRUCTIONS: 1. Check the fans and ensure that the ambient temperature on the site is acceptable. 2. If that does not help, replace the alarming RF Module.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
Post test failed 1925: EFaultId_FrPostTestFailed An RF Module power-on self-test failed at start-up. Replace the faulty unit.
FAULT NAME FAULT ID MEANING
: R-bus error : 425: EFaultId_RbusError : UltraSite, MetroSite, MetroSite 50, Triple-mode: The bus between the WSP and WTR does not work. The R-bus errors are probably caused by a faulty WSM or WTR. FlexiBTS: Error in the FSP or in the connection between the FSP and FCM. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode: 1. If the WSM/WMC also generates an alarm from a WTR unit, check the WTR and WSM cable. 2. If there are no active WSM/WMC alarms, the reason for the alarm is a faulty WSM/WMC or WSP. 3. Run a WCDMA BTS loop test to locate the faulty unit. 4. If the WSP is faulty, block/unblock it. 5. Replace the faulty unit. FlexiBTS: 1. Check the cabling between the System Module and RF Module.
DN99580892
Id:0900d805809d5c0d Confidential
189
7654 CELL OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
2. Check the active RF Module alarms and act accordingly. 3. Replace the faulty module (System Module).
FAULT NAME FAULT ID
: RET antenna control failure : 1842: EFaultId_MotorJamAl 1843: EFaultId_ActuatorJamAl 1844: EFaultId_NotCalibratedAl 1845: EFaultId_NotConfiguredAl 1846: EFaultId_ActuatorInterferenceAl MEANING : Antenna tilting is not possible or might function incorrectly. INSTRUCTIONS: 1. Recalibrate the RET antenna. 2. If that does not help, replace the RET unit.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
RF BB bus configuration error 1905: EFaultId_FrRfBbBusConfigError The RF Module baseband bus is configured incorrectly. 1. Block/unblock the RF Module. 2. If that does not help, block/unblock the site. 3. If that does not help, replace the faulty unit.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
RF BB bus connection transmission error 1906: EFaultId_FrRfBbBusConnTransError There is an error in the baseband or optical bus. 1. Block/unblock the RF Module. 2. If that does not help, block/unblock the site. 3. If that does not help, replace the alarming RF Module.
FAULT NAME FAULT ID MEANING
: RF BB bus synchronization error : 1904: EFaultId_FrRfBbBusSynchError : The baseband bus between the System Module and the RF Module is out of synchronization. INSTRUCTIONS: Note: In case of old RF HW rel1, start directly from step 2. 1. Check cables between the System Module and the RF Module. 2. Block/unblock the RF Module. 3. If that does not help, block/unblock the site. 4. If that does not help, replace the faulty unit
FAULT NAME FAULT ID MEANING
: RF Module Filter input power missing : 1910: EFaultId_FrFilterInputPowerMissing : The RF Module filter has measured a TX power that is too low. INSTRUCTIONS: 1. Block/unblock the RF Module. 2. If that does not help, replace the alarming RF Module.
190
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7654 CELL OPERATION DEGRADED
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
RF Module Overheat 1913: EFaultId_FrOverheat The RF Module temperature is too high. 1. Check the fans and ensure that the ambient temperature on the site is acceptable. 2. If that does not help, replace the faulty unit.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
RF Module blocked 1931: EFaultId_FrBlocked A shared (Medusa) FR is blocked. Unblock the alarming module.
FAULT NAME FAULT ID MEANING
: RF Module configuring failed : 1900: EFaultId_FrConfiguringFailed : The RF Module configuration failed because of a HW or SW fault. INSTRUCTIONS: Replace the alarming RF Module.
FAULT NAME FAULT ID MEANING
: RF Module critical file not found : 1901: EFaultId_FrCriticalFileNotFound : A critical configuration file is missing from the RF Module. INSTRUCTIONS: Replace the alarming RF Module.
FAULT NAME FAULT ID MEANING
: RF Module failure : 3010: EFaultId_RfModuleFailure : The FlexiBTS has detected an abnormal operation or a failure in the internal functionality of the RF Module. INSTRUCTIONS: Note: Perform the steps below in the listed order until the alarm disappears. 1. Check the other active BTS alarms (System Module failure, Baseband Bus failure, Failure in optical RP3 interface and Antenna Line Device failure) and act accordingly. 2. Reset the alarming RF Module by blocking/unblocking it. 3. Check cables between the System Module and the RF Module. 4. If that does not help, replace the faulty RF Module.
FAULT NAME FAULT ID MEANING
: RF Module file not found : 1902: EFaultId_FrFileNotFound : The RF Module SW detected that a non-critical configuration file is missing. INSTRUCTIONS: 1.Block/unblock the RF Module.
DN99580892
Id:0900d805809d5c0d Confidential
191
7654 CELL OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
2.If that does not help, replace the alarming RF Module.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
RF Module gain adjusting failure 1908: EFaultId_FrGainAdjust The TX output power adjustment failed. 1. Block/unblock the RF Module. 2. If that does not help, replace the alarming RF Module.
FAULT NAME : RF Module out of order FAULT ID : 1912: EFaultId_FrOutOfOrder MEANING : The RF Module is out of order because of a software or hardware fault. INSTRUCTIONS: 1. Block/unblock the RF Module. 2. If that does not help, replace the alarming RF Module.
FAULT NAME FAULT ID MEANING
: RF Module power output faulty : 1918: EFaultId_FrPowerOutputFault : The Power Supply has detected an overvoltage, undervoltage, or overcurrent in the RF Module. INSTRUCTIONS: 1. Block/unblock the RF Module. 2. If that does not help, replace the faulty unit.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
RF power decreased 1927: EFaultId_FrPowerDecreased The highest temperature exceeds the power decrease limit. 1. Check the fans and ensure that the ambient temperature on the site is acceptable. 2. If that does not help, block/unblock the alarming RF Module. 3. If that does not help, replace the alarming RF Module.
FAULT NAME FAULT ID MEANING
: RP3 RX data frame timing error : 5003: EFaultId_BofuRxAlignErr : The RP3 RX receiver has detected that the incoming data frame is outside of the alignment window. INSTRUCTIONS: 1. Reset BTS. 2. If resetting the BTS does not help, replace the WSMF.
FAULT NAME FAULT ID MEANING
192
: RP3 uplink/downlink buffering error : 5005: EFaultId_BofuUlBufErr 5006: EFaultId_BofuDlBufErr : Uplink buffering from Rbus to RP3, or vice versa downlink buffering from RP3 to Tbus does not work. Timing parameters
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7654 CELL OPERATION DEGRADED
DELTA/RBUS_START_TIME, and/or PI/TBUS_START_TIME are incorrectly set. INSTRUCTIONS: 1. Reset BTS. 2. If resetting the BTS does not help, replace the WSMF.
FAULT NAME FAULT ID MEANING
: RS485 IUANT port failure : 4069: EFaultId_Rs485PowerFailureAl : Radio Module or Filter (all others) has detected overcurrent on RS485 IUANT port. Some antenna line device is causing overload. Depending on HW implementation, antenna line devices powered by the RS485 IUANT and/or powered by antenna line are out of order. Overcurrect was detected on RS485 IUANT port. Some antenna line device is causing overload or shortcut exists on the port. Antenna line devices powered by the rs485 IUANT port are out of order. INSTRUCTIONS: 1. Check the RS485 IUANT i/f and antenna line devices. Fix or replace the faulty parts/devices. 2. Alarm is cancelled only at RF Module reset or the BTS reset.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
RX out of order 1911: EFaultId_FrRxOutOfOrder The RF Module RX RF synthesizer is not locked. FlexiBTS: 1. Block/unblock the RF Module. 2. If that does not help, replace the faulty unit. FlexiLiteBTS: 1. BTS reset. 2. If that does not help, replace the FlexiLiteBTS.
FAULT NAME FAULT ID MEANING
: Radio resources switched off : 4057: EfaultId_RfSwitchedOffAl : The TX carriers served by the affected antenna lines are disabled, which causes degradation of operation of the related cells or their deactivation. This reduces the power transmitted by the Power Amplifier in Radio Module for the sake of protecting the Power Amplifier against HW failure caused by operation under excessive VSWR value conditions (antenna line impedance mismatch). INSTRUCTIONS: 1. Check the antenna lines: antennas, antenna cables, connector torques, and antenna line devices. 2. Check the antenna line (TX-cable-antenna) impedance matching.
FAULT NAME
DN99580892
: Rbus data clock missing
Id:0900d805809d5c0d Confidential
193
7654 CELL OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
FAULT ID MEANING
: 5011: EFaultId_BofuRbusClockError : Data traffic from Rbus to RP3 in BOFU FPGA is malfunctioning because of errors in the Rbus synchronization clock. INSTRUCTIONS: 1. Reset BTS. 2. If resetting the BTS does not help, replace the WSMF.
FAULT NAME FAULT ID MEANING
: Receiving failure in optical interface : 2002: EFaultId_OIC_RxAl : The incoming optical signal to the Small Form Factor Pluggable (SFP) is missing, too weak, or the fiber cable has been detached. The connection between the System Module and the RF Module (LTX, Antenna Filter, Antenna Line Device) or between the Master System Module and the Extension System Module is broken. That might concern primary or secondary link. INSTRUCTIONS: 1. Check the status of the module behind the faulty link (Power on, and so on). 2. Check the SFP from both ends (the System Module and the module behind the faulty link). The optical interface LED indicates the faulty SFP. Replace the SFP if it is faulty. 3. Clean the connectors, test the fiber cable, and replace it if faulty. 4. If the steps above do not help, replace the module behind the faulty link.
FAULT NAME FAULT ID
: Rx signal level failure : 133: EFaultId_RxAntennaSignalLevelTooLowAl 134: EFaultId_RxAntennaSignalLevelDifferenceTooHighAl MEANING : The RX signal level is less than -112dBm or the difference between the maximum and minimum power levels of all RX antennas in the same cell and sector is more than the limit (EUBB/Nora 4 dB/Flexi value of LCELW-rxSignalComparations (in dBm)). INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode: 1. Check BTS Site Manager for received signal levels to find out which RX is causing the problem. 2. If an MHA is alarming, replace the MHA unit and check if the RX signal level failure alarm is canceled. 3. If the alarm still exists, check the antenna cables. Swap the main and diversity RF cables between the WTR and WAF to see if the problem is in the WTR. If RX values do not change between the WTR inputs when swapping the cables, the fault is in the WTR unit. Change the WTR unit. 4. If the WTR is not faulty, the WAF, antenna feeder, or antenna is faulty on the antenna line which has the inadequate RX level. Check and replace the faulty equipment. FlexiBTS:
194
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7654 CELL OPERATION DEGRADED
1. Check BTS Site Manager for the received signal levels to find out which RX is causing the problem. 2. If an MHA is alarming, replace the MHA unit and check if the RX signal level failure alarm is canceled. 3. If there are some Antenna line devices, check them. 4. Check the antenna cables. The radio module, antenna feeder, or antenna is faulty on the antenna line which has the inadequate RX level. Check and replace the faulty equipment. Note: The RX value in BTS Site Manager is refreshed at one minute intervals.
FAULT NAME FAULT ID
: SW corrupted : 1850: EFaultId_SwCorruptedAl 4029: EFaultId_SwCorruptedPermanentAl MEANING : A corrupted SW file in the FLASH is detected. Unit cannot complete start-up. INSTRUCTIONS: Update the SW to the BTS.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
FAULT NAME FAULT ID MEANING
TX out of order 1907: EFaultId_FrTxOutOfOrder The RF Module TX path is not usable. FlexiBTS: 1. Block/unblock the RF Module. 2. If that does not help, replace the faulty unit. FlexiLiteBTS: 1. Reset BTS. 2. If that does not help, replace the FlexiLiteBTS.
: TX output power measurement fault : 103: EFaultId_MeasurementAl : UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: The WTR or WPA/WMP/WOU output power measurement has failed. FlexiBTS: The RF Module output power measurement has
failed. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: 1. Block/unblock the alarming unit. If there was an internal failure, the unit needs to be blocked/unblocked to get it initialized/configured again. 2. Check the units and the RF cabling between the WPA/WMP/WOU and WTR units. FlexiBTS: 1. Reset the alarming RF Module with the block/unblock function. If there was an internal failure or sticking in
DN99580892
Id:0900d805809d5c0d Confidential
195
7654 CELL OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
the unit SW, the Module needs to be blocked/unblocked to get it initialized/configured again. 2. Check the cables between the System Module and RF Module. 3. If that does not help, replace the faulty RF Module.
FAULT NAME FAULT ID
: Telecom configuration failure : 109: EFaultId_TcomSlaveRegAl 110: EFaultId_UnitRnwConfigAl 111: EFaultId_TcomSlaveConfigAl 119: EFaultId_WspAllocationAl MEANING : Telecom slave configuration or registration failure. Unit RNW configuration failure. Telecom RNW reconfiguration failure. FlexiBTS: - FSP unit to FCM allocation failure - Faraday unit to FSP allocation failure Note that depending on the fault source, unit status might relate either to the state of particular carrier resource on FR module or FSP board on FCM, and may not be in line with the state of source HW unit. Or UltraSite, MetroSite, MetroSite 50, Triple-mode: WSP unit to WAM allocation failure. UltraSite/EUBB: Faraday unit to WSPF allocation failure. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: Block/unblock the alarming unit. If there was an internal failure, the unit needs to be blocked/unblocked to get it initialized/configured again. UltraSite/EUBB: If the alarming unit is WSPF, block/unblock the EUBB subrack. FlexiBTS: If there was an internal failure, in the case of an FR, the module needs to be blocked/unblocked to get it initialized/configured again. FlexiBTS Rel2: If the alarming unit is FSPC, block/unblock the alarming module.
FAULT NAME FAULT ID MEANING
: Temperature alarm : 3040: EFaultId_TemperatureAlarm : The internal temperature of the RF Module or System Module exceeds the threshold value, or the ambient temperature of the module(s) is beyond the specified limits. INSTRUCTIONS: Note: Perform the steps below in the listed order. 1. Check other BTS faults and act accordingly. 2. Check the ambient temperature of the BTS modules. If the ambient temperature is too high, make sure the airflow to the BTS modules is unobstructed, that is, the BTS modules
196
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7654 CELL OPERATION DEGRADED
are not covered with anything. If the ambient temperature is too low, it takes a while for the BTS modules to heat themselves to the threshold value. 3. Reset the alarming module/unit by blocking/unblocking it. 4. Replace the alarming module/unit.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
Timeout, commissioned resource not ready 35: EFaultId_UnitIsNotInUse The faulty unit has not been configured or initialised. Recommission the site.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
Transmission quality deteriorated 1921: EFaultId_FrTransmissionQualityDetoriated The TX signal adjustment fails. 1. Block/unblock the RF Module. 2. If that does not help, replace the alarming RF Module.
FAULT NAME
: Under- / overrunning error in RP3 serializer clock crossing FIFO FAULT ID : 5002: EFaultId_BofuRxClkError MEANING : Either too large clock jitter between received signal and internal clock, or missing data input signal. The receiver is started up again. INSTRUCTIONS: 1. Reset BTS. 2. If resetting the BTS does not help, replace the WSMF.
FAULT NAME FAULT ID MEANING
: Unit (module) dangerously overheating : 1937: EFaultId_FrDangerouslyOverheat : Validated sensor temperature is greater than or equal to the predefined value on unit property file. INSTRUCTIONS: 1. Check the fans and ensure that the ambient temperature on the site is acceptable. 2. If that does not help, replace the faulty unit.
FAULT NAME FAULT ID MEANING
: Unit SW download failed : 6: EFaultId_SwDownloadAl : Software update to a unit/subunit or module has failed. UltraSite, MetroSite: The fault can also be caused by disconnected CIF bus cables. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: 1. Download the BTS SW again. 2. If the alarming unit is WSP, block/unblock the WSP. 3. If the alarming unit is WAM or WPA, reset the BTS. 4. If that does not help, replace the alarming unit.
DN99580892
Id:0900d805809d5c0d Confidential
197
7654 CELL OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
FlexiBTS: 1. Download the BTS SW again. 2. FCM: Reset the BTS. 3. If Step 2 does not help, replace the alarming module. FlexiLiteBTS: 1. Download the BTS SW again. 2. Reset the BTS. 3. If Step 2 does not help, replace the Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: Unit blocked : 48: EFaultId_UnitBlockedAl : A unit is blocked with BTS Site Manager. The purpose of the fault is to avoid alarms that might be raised during the unit maintenance task. INSTRUCTIONS: To cancel the alarm, unblock the unit/module.
FAULT NAME FAULT ID
: Unit initialization failure : 12: EFaultId_TcomConfigAl 13: EFaultId_AtmConfigAl 15: EFaultId_InitializationAl 4040: EFaultId_InitFaultManAl MEANING : A unit/module or an IP address initialization has failed. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode, UltraSite/EUBB: 1. Block/unblock the alarming unit. 2. Check if the non-commissioned WAM is the Master WAM. If so, this causes the fault. Check the fault history to find out why the WAM switch-over occurred. 3. If the WAM is the fault source, check the RNC IP address in the commissioning file and modify the file if needed. If that does not help, perform a power-off reset. 4. If step 3 does not help, replace the alarming unit. FlexiBTS: 1. Block/unblock the alarming module. If that does not help, replace the alarming module. 2. If the FCM/FCT is the fault source, check the RNC IP address in the commissioning file and modify the file if needed. If that does not help, perform a power-off reset. 3. If Step 2 does not help, replace the alarming module. FlexiLiteBTS: 1. Block/unblock the alarming module. If that does not help, replace the alarming module. 2. If the SCR is the fault source, check the RNC IP address in the commissioning file and modify the file if needed. If that does not help, perform a power-off reset. 3. If Step 2 does not help, replace the alarming module.
FAULT NAME
198
: Unit not supported by current BTS SW version
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7654 CELL OPERATION DEGRADED
FAULT ID MEANING
: 95: EFaultId_NotSupportedUnit : An unsupported unit has been detected in the BTS. Typically, this happens when a new unit version is installed and there is older BTS SW in use that does not support the new unit version. INSTRUCTIONS: FlexiBTS, UltraSite/EUBB:: 1. Upgrade the system module SW. 2. Replace the unit. FlexiLiteBTS: 1. Upgrade the Flexi Lite BTS software. 2. Replace the Flexi Lite BTS.
FAULT NAME : Unit unidentified FAULT ID : 1923: EFaultId_FrUnitUnidentified MEANING : The permanent memory in the module is corrupted and the module product code or serial number is missing, or the module product code is unknown. INSTRUCTIONS: 1. Block/unblock the RF Module. 2. If that does not help, replace the alarming RF Module.
FAULT NAME FAULT ID MEANING
: Unknown HW resource : 94: EFaultId_UnknownUnitType : A unit cannot be identified by its product code or by its physical device address (object ID). INSTRUCTIONS: FlexiBTS: Replace the alarming unit/module. FlexiLiteBTS: Replace the Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: Unknown product code : 93: EFaultId_UnknownProductCode : A module cannot be identified by its product code but is known by its physical device address (object_ID). INSTRUCTIONS: UltraSite/EUBB: Replace the alarming module. FlexiBTS: Replace the alarming module. FlexiLiteBTS: Replace the Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: VSWR major alarm : 1837: EFaultId_VSWRMajorAl : VSWR value exceeds the defined level. The antenna line is mismatched or damaged. INSTRUCTIONS: 1. Check the antenna cables, connectors, antenna, and possible antenna line devices. 2. Check the antenna line (TX-cable-antenna) impedance matching.
DN99580892
Id:0900d805809d5c0d Confidential
199
7654 CELL OPERATION DEGRADED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
FAULT NAME FAULT ID MEANING
: VSWR minor alarm : 1838: EFaultId_VSWRMinorAl : Radio Module (60W RRH)/the Filter (all others) has detected a VSWR value exceeding the defined level. The antenna line is slightly mismatched. INSTRUCTIONS: 1. Check the antenna cables, connectors, antenna and possible antenna line devices. 2. Check the antenna line (TX-cable-antenna) impedance matching.
FAULT NAME FAULT ID
: WAF low noise amplifier faulty : 800: EFaultId_Lna1Al 801: EFaultId_Lna2Al 805: EFaultId_Lna3Al 806: EFaultId_Lna4Al 810: EFaultId_Lna5Al 811: EFaultId_Lna6Al MEANING : One of the two RX pre-amplifiers (one in the main branch and the other in the diversity branch) is faulty. The LED indicates the faulty unit. MetroSite 50: One, some, or all of the RX pre-amplifiers (max 6) are faulty. The LED indicates the faulty unit(s). INSTRUCTIONS: 1. Block/unblock the WAF unit. This is most likely a HW fault, but blocking/unblocking the unit ensures that before a site visit. 2. If that does not help, replace the alarming unit.
FAULT NAME FAULT ID
: WSM RR-Bus error : 1189: EFaultId_Rr0_0ParityErr2 1191: EFaultId_Rr0_0SyncErr2 1193: EFaultId_Rr0_1ParityErr2 1195: EFaultId_Rr0_1SyncErr2 1197: EFaultId_Rr1_0ParityErr2 1199: EFaultId_Rr1_0SyncErr2 1201: EFaultId_Rr1_1ParityErr2 1203: EFaultId_Rr1_1SyncErr2 MEANING : The signal is transported from the WTR to the WSP via the WSM. This alarm is generated when the WSM/WMC unit detects errors in the incoming RR bus from the WTR unit. The reason for the failure is probably the WTR or WSM/WMC unit. The unit may have been installed incorrectly or the backplane cabling is faulty. INSTRUCTIONS: 1. Run the WCDMA BTS loop test. 2. Replace the units indicated in the alarm one by one and check whether the problem is cleared. 3. Check the backplane cables and connectors (see Troubleshooting instructions).
200
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7654 CELL OPERATION DEGRADED
FAULT NAME FAULT ID MEANING
: WSM failure : 3001: EFaultId_EubbWsmAl : The BTS has detected an abnormal operation or a failure in the internal functionality of the WSMF unit. INSTRUCTIONS: Note: Perform the steps below in the listed order until the alarm disappears. 1. Check the alarm history, alarming unit and subrack. 2. Check that the unit is properly connected. If the unit LED does not light up, the unit is faulty. 3. Reset the BTS. 4. Replace the alarming unit. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
DN99580892
Id:0900d805809d5c0d Confidential
201
7655 CELL NOTIFICATION
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
33 7655 CELL NOTIFICATION Meaning A minor fault (or faults) has occurred in a unit/module (or units/modules) that belong to the sector indicated in the alarm. Check the reason for the fault from the supplementary text field of the alarm. The effect of the fault on the functioning of the network element depends on the fault description. For more information, see base station fault descriptions in WCDMA RAN and Flexi Direct System Libraries. Supplementary information fields 1
rack (cabinet) number
2
shelf number
3
slot
4
type of unit
5
unit number
6
subunit number For more information, see instructions on Alarm Structure. Instructions
Verify the configuration of a BTS by checking the commissioning, cabling and correct installation of the units/modules at the BTS. Make sure the environment does not cause the fault. Before a unit/module is replaced at the BTS, the site should be reset to recover from any temporary faults which might have caused the malfunctioning of the unit/module. When an active alarm is a 'Start' alarm, a site reset is required to cancel the alarm. If the site reset or module block/unblock does not help, replace the faulty unit/module (see the source of the alarm and instructions fields of the corresponding alarms). Below is the list of BTS fault(s) which may have caused this alarm in BTS WN 8.0 release. In case of earlier SW release and in case you need more detailed fault descriptions refer to WCDMA RAN and Flexi Direct System Libraries. The BTS fault descriptions are also included in BTS SW release documentation. If that does not help,
202
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7655 CELL NOTIFICATION
contact your local Nokia Siemens Networks representative.
FAULT NAME FAULT ID
: Antenna Line Device Operation Failure : 1871: EFaultId_BusyAl 1872: EFaultId_FormatErrorAl 1873: EFaultId_UnsupportedProcedureAl 1874: EFaultId_OutOfRangeAl MEANING : The device is not working properly, the configuration is not valid, or a given parameter is incorrect. INSTRUCTIONS: 1. Check the functionality of the antenna line device. 2. Check the compatibility between the antenna line device and the BTS. 3. Check that the given parameters are in the valid range.
FAULT NAME FAULT ID MEANING
: Antenna Line Device failure : 3100: EFaultId_AntennaLineFailure : The System Module or the device itself has detected an abnormal operation or a failure in the antenna line device. INSTRUCTIONS: Note: Perform the steps below in the listed order until the alarm disappears. 1. Check the antenna line and antenna line devices. Make sure that the antenna line connectors are in the right torque. 2. Reset the alarming RF module by blocking/unblocking it. 3. Replace the faulty parts and/or devices along the antenna line. 4. Replace the RF Module.
FAULT NAME FAULT ID
: Antenna line device SW download failure : 4047: EFaultId_FileCrcErrorAl 4048: EFaultId_FileContentErrorAl MEANING : SW download to an antenna line device failed due to incorrect checksum or file format. INSTRUCTIONS: Note: Perform the steps below in the listed order until the BTS fault disappears. 1. Check the SW package. 2. Download SW to the antenna line device again.
FAULT NAME FAULT ID
: BTS SW download or activation failed : 29: EFaultId_FileCorruptionAl 30: EFaultId_SwUpdateAl MEANING : The SW update to the BTS has failed. The error can be caused by a unit reset during the SW update, a hardware problem in the unit or cabinet, or a corrupted flash file system. INSTRUCTIONS: FlexiBTS: 1. Retry the SW update.
DN99580892
Id:0900d805809d5c0d Confidential
203
7655 CELL NOTIFICATION
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
2. If other flash memory-related faults are active for the alarming module at the same time, replace the alarming module. FlexiLiteBTS: 1. Retry the SW update. 2. If other flash memory-related faults are active for the Flexi Lite BTS at the same time, replace the Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: Baseband Bus failure : 3020: EFaultId_BaseBandBusFailure : The BTS has detected an abnormal operation or a failure in the BTS internal baseband bus. The failure cannot be pointed to a specific unit/module but there are several possible fault sources. INSTRUCTIONS: Note: Perform the steps below in the listed order. FlexiBTS: 1. Check other active BTS alarms and act accordingly. 2. Check the cables between the System Module and RF Module/Extension System Module. 3. Reset the RF Module and/or System Module, depending on the alarm source: a. Reset the RF Module by blocking/unblocking it. b. Reset the Extension System Module by blocking/unblocking it. c. Reset the master System Module. 4. Replace the alarming RF Module/Extension System Module. 5. If the master System Module is the source or replacing the RF Module/Extension System Module does not clear the fault situation, replace the alarming master System Module. UltraSite/EUBB: 1. Check other active BTS alarms and act accordingly. 2. Reset the alarming unit. 3. Check the cables in backplane. 4. Replace the alarming unit. FlexiLiteBTS: 1. Check other active BTS faults and act accordingly. 2. Reset the BTS by blocking/unblocking it. 3. Replace the Flexi Lite BTS.
FAULT NAME FAULT ID MEANING
: Configuration error: : 3070: EFaultId_ConfigurationError : There is an incompatibility problem in the BTS HW/SW versions or the HW/HW configuration. Another possibility is that there is a mismatch between the BTS configuration and the RNC/Flexi Direct RNC parameters. INSTRUCTIONS: Note: Perform the steps below in the listed order. 1. Check the installed HW/SW version compatibility and the HW compatibility with the current BTS configuration.
204
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7655 CELL NOTIFICATION
2. Check that the BTS cell parameters from the RNC/Flexi Direct RNC match the BTS HW configuration (for example frequency, power). 3. Check the RNC/Flexi Direct RNC BTS faults for the alarming local cell (LCR). 4. Recommission the BTS to ensure that all parameters are correctly configured.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
External Filter missing from LCR 1892: EFaultID_ExternalFilterMissingFromLcrAl An external filter is missing from the antenna line. Install an external filter to the antenna line.
FAULT NAME FAULT ID MEANING
: Fan failure : 3050: EFaultId_FanFailure : All the fans or more than one in the same fan group are rotating slower or faster than required, are not rotating at all, or the RPM information is not available for the fans. The reason for this fault can be too low supply voltage or a broken fan. INSTRUCTIONS: Note: Perform the steps below in the listed order. 1. Make sure that the fan is not blocked. 2. Check the fan and cabling. 3. Replace the faulty fan module.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
File corrupted in SW download 28: EFaultId_SwPackageAl The download is corrupted or incorrectly formed SW. UltraSite, MetroSite, MetroSite 50, Triple-mode: 1. Retry the SW update. 2. Fetch the BTS log files and check the download status from the BTS SWDLreport. FlexiBTS, FlexiLiteBTS: 1. Retry the SW update. 2. Save the snapshot and check the download status from the BTS SWDLreport in the snapshot file.
FAULT NAME FAULT ID MEANING
: HSUPA capacity decreased : 135: EFaultId_HsupaCapacityDecreasedAl : Runtime recovery, for example, has changed the HSUPA allocation so that the maximal HSUPA capacity cannot be achieved with the current allocation of baseband resources. INSTRUCTIONS: 1. If you want to increase the maximal HSUPA capacity while the alarm is active, lock and unlock all the cells from the alarming LCG. 2. Reset the BTS.
DN99580892
Id:0900d805809d5c0d Confidential
205
7655 CELL NOTIFICATION
FAULT NAME FAULT ID
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
: Incompatible SW version detected : 23: EFaultId_IncompatibleSwVersionAl 24: EFaultId_ObsoleteSwVersionAl
MEANING : A new unit with incompatible SW has probably been inserted in the BTS. INSTRUCTIONS: Update compatible SW to the BTS (check the SW versions to see the active SW version, and update the active SW version), unless it is automatically updated by NetAct. NOTE: If also fault 10:EFaultId_NoConnectionToUnitAl is active on the source unit then SW update should be postponed until fault 10:EFaultId_NoConnectionToUnitAl is cancelled. Related BTS - AXC interface: check the SW version of the BTS and AXC, and update compatible SW to the AXC or BTS.
FAULT NAME FAULT ID MEANING
: LCRs using same carrier frequencies mismatch in LCGs : 1865: EFaultId_LcrCarrierFreqLcgAl : Two cells with the same carrier belong to different local cell groups (LCGs). When baseband pooling is used, BTS baseband resources are divided between the different LCGs. Softer handover requires that cells with the same frequency in different sectors need to be assigned to the same LCG. This alarm is reported to BTS Site Manager only. INSTRUCTIONS: Check the RNC parameters for the BTS cells and change them, if needed. BTS reset is needed to take changed frequencies into use and to clear the fault.
FAULT NAME FAULT ID MEANING
: RF module optical interface confguration failure : 1929: EFaultId_FrOptIfConfFailAl : The rel 2.0 or rel2.1 RF Module with SW before the implementation of RAN2312( Radio Interface Harmonization in Rel2.x ) is connected to the system module using optical interface 2 that is not according to the user guidance. It is advised to use optical interface 1. INSTRUCTIONS: Reconnect the alarming release 2 RF Module to optical interface 1.
FAULT NAME FAULT ID MEANING
206
: Radio resources switched off : 4057: EfaultId_RfSwitchedOffAl : The TX carriers served by the affected antenna lines are disabled, which causes degradation of operation of the related cells or their deactivation. This reduces the power
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7655 CELL NOTIFICATION
transmitted by the Power Amplifier in Radio Module for the sake of protecting the Power Amplifier against HW failure caused by operation under excessive VSWR value conditions (antenna line impedance mismatch). INSTRUCTIONS: 1. Check the antenna lines: antennas, antenna cables, connector torques, and antenna line devices. 2. Check the antenna line (TX-cable-antenna) impedance matching.
FAULT NAME FAULT ID
: Rbus synchronization error : 5010: EFaultId_BofuRbusParityError 5012: EFaultId_BofuRbusSyncLost MEANING : Data traffic into Rbus uplink buffers is malfunctioning because of errors in the Rbus synchronization clock. Either Rbus synchronization pattern not found or parity errors found in pattern. INSTRUCTIONS: 1. Reset BTS. 2. If resetting the BTS does not help, replace the WSMF.
FAULT NAME FAULT ID MEANING
: Read-only field encountered in the antenna line device : 4140: EFaultId_ReadOnlyAl : An attempt to modify a field value in Antenna Line Device failed because the field is read-only. INSTRUCTIONS: No action required from the operator.
FAULT NAME FAULT ID MEANING
: TX failure in MIMO : 4003: EFaultId_TxFailureTurnMimoOffAl : Due to TX path failure MIMO (Multiple Input Multiple Output) functionality is not operational in the cell related to the faulty TX. INSTRUCTIONS: The affected cell starts working as a non-MIMO cell automatically. It does not require any manual change. The cell operates as a non-MIMO cell as long as the TX that is responsible for transmission of S-CPICH for the cell remains in "Faulty" state. Check the other active BTS faults and act accordingly.
FAULT NAME FAULT ID
: Telecom cell enabling or disabling failed : 115: EFaultId_CellEnablingFailureAl 116: EFaultId_CellDisablingFailureAl MEANING : The cell enabling (the setup of CPICH and BCH) failed, or the cell disabling (the release of common channels) failed. The reason could be a hardware or a bus problem, or a lack of DSP or transport resources. INSTRUCTIONS: UltraSite, MetroSite, MetroSite 50, Triple-mode: 1. Check other active alarms if the WSP capacity has been decreased.
DN99580892
Id:0900d805809d5c0d Confidential
207
7655 CELL NOTIFICATION
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
2. Check if there are enough WSP units. FlexiBTS: 1. Check other active alarms. 2. Check the number of FSP units. UltraSite/EUBB: 1. Check other active alarms if the WSPF capacity has been decreased. 2. Check if there are enough WSPF units.
FAULT NAME FAULT ID MEANING
: Temperature alarm : 3040: EFaultId_TemperatureAlarm : The internal temperature of the RF Module or System Module exceeds the threshold value, or the ambient temperature of the module(s) is beyond the specified limits. INSTRUCTIONS: Note: Perform the steps below in the listed order. 1. Check other BTS faults and act accordingly. 2. Check the ambient temperature of the BTS modules. If the ambient temperature is too high, make sure the airflow to the BTS modules is unobstructed, that is, the BTS modules are not covered with anything. If the ambient temperature is too low, it takes a while for the BTS modules to heat themselves to the threshold value. 3. Reset the alarming module/unit by blocking/unblocking it. 4. Replace the alarming module/unit.
FAULT NAME FAULT ID MEANING
: Temperature too low (heating ongoing) : 1922: EFaultId_FrTemperatureTooLow : During RF startup: the temperature inside the RF Module is too low. Heating of module is ongoing. Wait until the alarm is canceled. This might take up to 30 minutes. During RF runtime: the temperature inside the RF module is too low. A problem may occur. INSTRUCTIONS: During RF startup only: 1. Heating of module is ongoing. Wait until the alarm is canceled. This might take up to 30 minutes. 2. If that does not help, block/unblock the RF Module. 3. If that does not help, replace the alarming RF Module.
FAULT NAME FAULT ID MEANING
: Unit (module) temperature is high : 1936: EFaultId_FrTempHigh : Validated module temperature is higher than the predefined maximum allowed value. INSTRUCTIONS: Check the fans and ensure that the ambient temperature on the site is acceptable.
FAULT NAME
208
: WSM failure
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7655 CELL NOTIFICATION
FAULT ID MEANING
: 3001: EFaultId_EubbWsmAl : The BTS has detected an abnormal operation or a failure in the internal functionality of the WSMF unit. INSTRUCTIONS: Note: Perform the steps below in the listed order until the alarm disappears. 1. Check the alarm history, alarming unit and subrack. 2. Check that the unit is properly connected. If the unit LED does not light up, the unit is faulty. 3. Reset the BTS. 4. Replace the alarming unit.
FAULT NAME FAULT ID
MEANING
: WSMA RR-Bus error : 1101: EFaultId_Wtr0ParityErr2 1103: EFaultId_Wtr0SyncErr2 1105: EFaultId_Wtr1ParityErr2 1107: EFaultId_Wtr1SyncErr2 1236: EFaultId_Rr2BusSyncErr2 1238: EFaultId_Rr2BusParityErr2 1240: EFaultId_Rr1BusSyncErr2 1242: EFaultId_Rr1BusParityErr2 : The WSMA/WMC unit has detected errors in the incoming RR bus from the WTR unit. The WTR or WSMA/WMC unit may have been installed incorrectly or the backplane cabling is faulty. This alarm is generated only once and reported to BTS
Manager only. INSTRUCTIONS: 1. Check the WSM and Spider cabling. 2. Replace the WTR and WSMA/WMC units indicated in the alarm one by one.
FAULT NAME FAULT ID
MEANING
DN99580892
: WSMA SR-Bus error : 1109: EFaultId_WsmSrLeftParityErr2 1111: EFaultId_WsmSrLeftSyncErr2 1113: EFaultId_WsmSrRightParityErr2 1115: EFaultId_WsmSrRightSyncErr2 : UltraSite: The WSM unit has detected errors in the incoming SR bus from the adjacent WSM unit. The reason for the failure is the cable between the WSM front panels or the WSM units indicated in the alarm. Triple-mode: The WSM has detected errors in the incoming SR bus from the WTR unit. The reason for the failure is the WSM or WTR unit, or the cable between the WSM front panel and the backplane. This alarm is generated only once and is reported to the BTS Site Manager only.
Id:0900d805809d5c0d Confidential
209
7655 CELL NOTIFICATION
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
INSTRUCTIONS: 1. Check the WSM cabling. 2. Remove/reinsert the alarming unit. 3. Check the other WSM units. 4. Replace the WSM units (and if that does not help, also the WTR units) indicated in the alarm one by one and check whether the alarm is cleared. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
210
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7660 BASE STATION LICENCE EXPIRED
34 7660 BASE STATION LICENCE EXPIRED Meaning A licence fault (or faults) has occurred in the base station. Check the reason for the fault from the supplementary text field of the alarm. The effect of the fault on the functioning of the network element depends on the fault description. For more information, see base station fault descriptions in WCDMA RAN and Flexi Direct System Libraries. Supplementary information fields 1
rack (cabinet) number
2
shelf number
3
slot
4
type of unit
5
unit number
6
subunit number
7
feature code
For more information, see instructions on Alarm Structure. Instructions See the BTS faults documents in WCDMA RAN and Flexi Direct System Libraries for details about BTS license management.
FAULT NAME FAULT ID MEANING
: Feature expires on , : 4002: EFaultId_LicenceExpired : The feature is expiring: - in one month or one week if the fault severity is minor (working); - has already expired if the fault severity is major (degraded). INSTRUCTIONS: Activate the required license.
DN99580892
Id:0900d805809d5c0d Confidential
211
7660 BASE STATION LICENCE EXPIRED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
212
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7661 BASE STATION LICENCE NOTIFICATION
35 7661 BASE STATION LICENCE NOTIFICATION Meaning A licence fault (or faults) has occurred in the base station. Check the reason for the fault from the supplementary text field of the alarm. The effect of the fault on the functioning of the network element depends on the fault description. For more information, see base station fault descriptions in WCDMA RAN and Flexi Direct System Libraries. Supplementary information fields 1
rack (cabinet) number
2
shelf number
3
slot
4
type of unit
5
unit number
6
subunit number
7
feature code
For more information, see instructions on Alarm Structure. Instructions See the BTS faults documents in WCDMA RAN and Flexi Direct System Libraries for details about BTS licence management.
FAULT NAME FAULT ID MEANING
: Failure in license activation : 4037: EFaultId_FailureInLicenceActivationAl : Generation of target Id failed and therefore correct validation of license files in BTS is not possible. BTSOM is restarted and in consequence during startup all license files are deleted from BTS. All optional features are either disabled or their capacity is reduced to the basic (not licensed) level. INSTRUCTIONS: Note! Perform the steps below in the listed order until the alarm disappears. 1. Reset the NetAct Licence Manager.
DN99580892
Id:0900d805809d5c0d Confidential
213
7661 BASE STATION LICENCE NOTIFICATION
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
2. Reset the BTS. 3. Check the BTS license situation: the correct licenses have been purchased and installed.
FAULT NAME FAULT ID MEANING
: Feature expires on , : 4002: EFaultId_LicenceExpired : The feature is expiring: - in one month or one week if the fault severity is minor (working); - has already expired if the fault severity is major (degraded). INSTRUCTIONS: Activate the required license.
FAULT NAME
: HW capacity too low for feature , FAULT ID : 1814: EFaultId_HWCapacityTooLowAl MEANING : The HW capacity is too low to support all licenses of an optional feature. INSTRUCTIONS: Delete the licenses or insert new hardware.
FAULT NAME FAULT ID MEANING
: Licence missing , : 1885: EFaultId_MissingLicense Al : The BTS detected a resource requiring a license but no license exists or is available. INSTRUCTIONS: Activate the appropriate license or increase the license amount.
FAULT NAME FAULT ID MEANING
: License missing , : 1833: EFaultId_LicenceMissingAl : The BTS detected a resource needing a license. However, no license exists or is free. INSTRUCTIONS: An appropriate license should be provided to BTS.
FAULT NAME FAULT ID MEANING
: TargetId verification failure : 4056: EFaultId_TargetIdVerificationFailureAl : NetAct Licence Manager did not respond to the verification request. TargetId verification was not possible. INSTRUCTIONS: Note! Perform the steps below in the listed order until the fault disappears. 1. Reset the NetAct Licence Manager. 2. Reset the BTS. 3. Check the BTS license situation: the correct licenses have been purchased and installed.
214
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7661 BASE STATION LICENCE NOTIFICATION
Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
DN99580892
Id:0900d805809d5c0d Confidential
215
7665 BASE STATION TRANSMISSION ALARM
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
36 7665 BASE STATION TRANSMISSION ALARM Meaning A transmission fault (or faults) has occurred in the BTS. This alarm is an encapsulation alarm that is used to transfer the Flexi Transport Submodule (FTM) alarm data over the BTS O&M connection through RNC and OMS to NetAct. Encapsulation is used because the RNC alarm system cannot support the FTM alarms directly due to differences in the alarm structure. In NetAct and OMS this alarm is shown in opened format. This means that the alarm number, alarm text and supplementary information are shown in original FTM format and the alarm printout is thus different in NetAct compared to alarm listings in RNC MML interface that shows these FTM alarms as instances of alarm number 7665. Check the reason for the fault from the supplementary information fields and supplementary text field of the alarm. The actual documentation for the encapsulated alarm can be found in the BTS faults documents in WCDMA RAN and Flexi Direct System Libraries. The effect of the fault on the functioning of the network element depends on the fault description. For more information, see base station fault descriptions in WCDMA RAN and Flexi Direct System Libraries. Supplementary information fields 1
probable cause reported by FTM
2
the managed object reported by FTM
3
alarm number reported by the FTM. The FTM has reserved alarm numbers from space 61000 - 61999 Instructions
This alarm is an encapsulation alarm for original FTM alarm. Follow up the instructions given in the BTS faults documents in WCDMA RAN and Flexi Direct System Libraries for the alarm number shown in supplementary information field 3.
FAULT NAME FAULT ID MEANING
216
: AIS (Administrative Unit) on unit $U, interface $IF : 61106: FTM_AIS_AU : Alarm indication signal on the Administrative Unit. The SDH interface receives an AU-AIS (Administrative Unit - Alarm Indication Signal). This signal is generated by an intermediate SDH device in the forward direction because it detects a problem in its receive signal. All other
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7665 BASE STATION TRANSMISSION ALARM
transmission alarms related to this signal are suppressed. Probable cause: There is a transmission problem somewhere in the intermediate network and AIS is sent instead of user traffic. INSTRUCTIONS: Check the intermediate transmission network for alarms indicating the root cause and follow the instructions for handling these alarms.
FAULT NAME FAULT ID MEANING
: AIS (Multiplexer Section) on unit $U, interface $IF : 61102: FTM_AIS_MS : Alarm indication signal on the Multiplexer Section. The SDH interface receives an MS-AIS (Multiplexer Section - Alarm Indication Signal). This signal is generated by an intermediate SDH device in the forward direction because it detects a problem in its receive signal. All other transmission alarms related to this signal are suppressed. Probable cause: there is a transmission problem somewhere in the intermediate network and AIS is sent instead of user traffic. INSTRUCTIONS: Check the intermediate transmission network for alarms indicating the root cause and follow the instructions for handling these alarms.
FAULT NAME FAULT ID MEANING
: AIS on unit $U, interface $IF : 61151: FTM_AIS : Alarm indication signal is received. This signal is generated by an intermediate PDH device in the forward direction because it detects a problem in its receive signal. All other transmission alarms related to this signal are suppressed. Probable cause: There is a transmission problem somewhere in the intermediate network and AIS is sent instead of user traffic. INSTRUCTIONS: Check the intermediate transmission network for alarms indicating the root cause and follow the instructions for handling these alarms.
FAULT NAME
: Auto-negotiation mismatch, on unit $U, Ethernet interface $IF FAULT ID : 61607: AUTO NEGO MIS MATCH MEANING : This alarm indicates that there is a mismatch between BTS configuration and auto-negotiation result. INSTRUCTIONS: Try with local management or site support equipment.
FAULT NAME
DN99580892
: Automatic BTS Operator Certificate retrieval unsuccessful
Id:0900d805809d5c0d Confidential
217
7665 BASE STATION TRANSMISSION ALARM
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
FAULT ID MEANING
: 61510: NO_CERTIFICATE : A requested certificate could not be retrieved from the certificate repository server (RA) or certificate authority (CA). A requested certificate could not be renewed from the certificate authority (CA). INSTRUCTIONS: Provide the certificate.
FAULT NAME FAULT ID MEANING
: BFD $session down, egress, $sourceIP to $destinationIP : 61606: BFD down egress : The alarm is raised if the alarm is enabled, the BFD state is not AdminDown, the BFD packet from the far end contains the diagnostic code = 'Control Detection Time Expired' AND no ingress alarm is present. INSTRUCTIONS: Check the BFD configuration at local end.
FAULT NAME FAULT ID MEANING
: BFD $session down, ingress, $sourceIP to $destinationIP : 61605: BFD DOWN Ingress : The alarm is raised if the alarm is enabled, the BFD state is not AdminDown, and no BFD packet is received at the local end during the detection time. INSTRUCTIONS: 1. Check the network between both BFD peers for physical link failures or misconfigurations. 2. Check if the BFD functionality in the peer is switched on and that the configurations of the BFD peers match.
FAULT NAME FAULT ID MEANING
: BFD group $bfdGrpId down : 61022: BFD DOWN : The alarm is raised if the BFD service is not available anymore for all sessions of the BFD group. The BFD failure for each session might be either in ingress or egress direction. In case only 1 BFD session is configured and activated for the BFD group, the alarm is raised, if BFD on this session fails in either ingress or egress direction. INSTRUCTIONS: 1) Check if the far end has BFD switched on. 2)Check cabling and network connections to the far end.
FAULT NAME FAULT ID MEANING
: BTS reset required : 61010: FTM_BTS_RESET_REQUIRED : A change to the BTS IP settings has been received from TRS Manager. The user has to confirm the changes after the last BTS IP settings have been given. The confirmation is needed so that the BTS IP settings are taken in use through a BTS reset. INSTRUCTIONS: Confirm the changes when all the required BTS IP settings have been made.
218
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7665 BASE STATION TRANSMISSION ALARM
FAULT NAME FAULT ID MEANING
: CCM fault md $d level $ fault $f prio $p cause $c : 61410: Ethernet OAM CCM fault : The alarm is triggered whenever a service OAM error related to the transmission of Continuity Check Messages (CCM) persists on a given Ethernet interface over the period 2,5 s. The following alarms are defined: 1) XC_CCM_defect, priority 5 (highest priority): Maintenace Domain level mismatch or Maintenance Association identification mismatch. 2) Error_CCM, priority 4: Maintenance End Point identifier unknown, wrong CCM interval. 3) Remote_CCM_Defect, priority 3: at least one of the remote peers does not receive CCM from its peers, or local does not receive CCM from peer since 3.5 times the transmission period. MA includes multiple VLANs, CCMs shall be received for each VLAN separately. 4) RDI_CCM, priority 1 (lowest priority): one remote peer detects RDI flag in the CCM frames. The alarm shall display the following information: Alarm Name Alarm Priority Alarm cause: if difference sources produce the same alarm MD name MD level at which the alarm was detected INSTRUCTIONS: 1) Check cabling. 2) Check CCM configuration at remote peer.
FAULT NAME FAULT ID MEANING
: CES pseudowire $W down on unit $U : 61071: CES_PW_DOWN : The alarm is raised if the CES pseudowire is in 'Up' state, but the number of received packets in the CES pseudowire is less than 10 relative to the expected number of packets for 1 second. The alarm is not be raised, if the CES pseudowire is in 'Init' state. INSTRUCTIONS: 1. Check that the cables are connected to the correct connectors. 2. Check that the interface at the far-end interface is switched on. 3. Check whether there are active alarms at the far end. If there are, follow the instructions for handling those alarms. 4. Check the configuration of the CES pseudowire.
FAULT NAME FAULT ID
DN99580892
: CES pseudowire remote packet loss on wire $W on unit $U : 61072: CES_PW_Remote_Packet_Loss
Id:0900d805809d5c0d Confidential
219
7665 BASE STATION TRANSMISSION ALARM
MEANING
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
: This alarm is raised if the packet loss condition for packets of the given CES pseudowire persists for more than
1 second in ingress. The packet loss condition is defined as follows: The CES over PSN pseudowire function is capable to detect lost and misordered packets. The sequence number in the control word is used for these purposes. The CES over PSN pseudowire function shall reorder misordered packets. Misordered packets that cannot be reordered, shall be discarded and treated as lost. INSTRUCTIONS: 1. Check that the cables are connected to the correct connectors. 2. Check that the interface at the far-end interface is switched on. 3. Check whether there are active alarms at the far end. If there are, follow the instructions for handling those alarms. 4. Check the configuration of the CES pseudowire.
FAULT NAME FAULT ID MEANING
: CES pseudowire tunnel $T down on unit $U : 61070: CES_PWT_DOWN : This alarm is raised if a CES pseudowire tunnel is in 'Up' state, but no IP packets were received on the tunnel in the last second. The alarm is not raised in case the CES pseudowire tunnel is in 'Init' state. In case that all CES pseudowires of the tunnel are taken out of use by the operator, also no "PW tunnel down" alarm is raised even when the CES pseudowire tunnel is still configured. INSTRUCTIONS: 1. Check that the cables are connected to the correct connectors. 2. Check that the interface at the far-end interface is switched on. 3. Check whether there are active alarms at the far end. If there are, follow the instructions for handling those alarms. 4. Check the configuration of the related CES pseudowires.
FAULT NAME FAULT ID MEANING
220
: CRL update failure due to cause $C : 61074: CRL Update failure : This alarm is raised if the BTS cannot update the Certificate Revocation List (CRL) for one of the following reasons: - The LDAP binding fails. - The LDAP search is emtpy (no CRL found). / The LDAP search contains more
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7665 BASE STATION TRANSMISSION ALARM
than one entry. - The CRL signature validation fails. - The CRL file exceeds the BTS storage limit. - The BTS certificate is part of the CRL. - DNS resolution for the CRL distribution point fails. INSTRUCTIONS: Execute general configuration checks: - Configuration of CMP server IP address and port and DNS server IP address - Configuration of routing entries towards remote peers - Configuration of IPSec policies towards remote peers Check remote peers and intermediate network elements interconnections. Check the LDAP connection towards the Certificate Revocation List server. Check DNS names. Check the size of the file at the Certificate Revocation List server.
FAULT NAME FAULT ID MEANING
: Config-abort state on unit $U, IMA Group $IMAG : 61178: FTM_IMA_CONFIG_ABORTED : Configuration abort state. This alarm is raised when the far end tries to use unacceptable configuration parameters. All other transmission alarms related to this signal are suppressed. Probable cause: The IMA group configuration is wrong (for example, the IMA versions are incompatible). INSTRUCTIONS: Check that the configurations at the near end and far end fit together (for example, IMA version and frame length). Change the configuration, if necessary.
FAULT NAME FAULT ID MEANING
: DHCP client timeout or NACK received on $IF $VID : 61608: DHCP_CLIENT_TIMEOUT : This alarm is raised if there is no response from any DHCP server after 6 minutes or a NACK is received. The alarm clears when the correct DHCPOFFER is received. VID will be displayed in case of VLAN. INSTRUCTIONS: Check the DHCP server configuration in BTS. Check the physical connectivity between DHCP server and BTS/FTM. Check whether the IP address is already assigned to another NE.
FAULT NAME FAULT ID MEANING
DN99580892
: DSCP $D signalled but not configured : 61020: DSCP UNKNOWN : DSCP $D signalled but not configured. $D specifies the first mismatch DSCP value. The combination of RNC and NodeB is misconfigured with regard to quality of the service configurations.
Id:0900d805809d5c0d Confidential
221
7665 BASE STATION TRANSMISSION ALARM
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
INSTRUCTIONS: 1. Check the configured DSCP value ranges in the RNC. 2. Check the configured DSCP value ranges in the BTS. 3. Ensure that both match each other.
FAULT NAME FAULT ID MEANING
: Dead Peer Detected : 61030: FTM_DPD : A dead peer was detected in one of the IPsec associations of the FTM. Possibly - a cable is cut or there is no cable connected to the interface - the signal is excessively attenuated - the port at the connected far end node is switched off INSTRUCTIONS: 1. Check that the cables are connected to the correct connectors. 2. Check that the interface at the far-end interface is switched on. 3. Check whether there are active alarms at the far end. If there are, follow the instructions for handling those alarms.
FAULT NAME FAULT ID MEANING
: EBER on unit $U, interface $IF : 61104: FTM_EBER : Excessive bit error rate. The measured bit error rate exceeds the threshold value of BER-3 (10E-3). Probable causes: - the signal level is too low (optical connectors or cables are dirty, electrical connectors or cables are corroded) - the specified maximum length of the cable is exceeded - the connector is not properly connected to the unit - the receiver or the far end transmitter has failed INSTRUCTIONS: 1. Clean the cables and connectors. 2. Check that the connectors are properly connected to the unit. 3. Check that the cable connected to the interface in question is not damaged and is within the specifications. 4. Follow the signal in the network and check whether any other alarms concerning the fault are on (such as Laser End of Life). If this is the case, follow the instructions for handling those alarms.
FAULT NAME FAULT ID MEANING
222
: ETH AIS fault interface $IF level $l mac addr $x : 61411: Ethernet OAM ETH_AIS_fault : A Maintenance Endpoint (MEP) received a valid ETH-AIS frame. The alarm shows the following information: - Maintenance Interface - Maintenance Domain level at which the alarm was detected
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7665 BASE STATION TRANSMISSION ALARM
- Source MAC address of the MEP. INSTRUCTIONS: 1) Check cabling. 2) Check configuration at remote peer.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
FTM booted at $date due to $RCause 61006: FTM_RESET The transport part of the WBTS has been reset. N/A
FAULT NAME FAULT ID MEANING
: Far end config-abort state on unit $U, IMA Group $IMAG : 61179: FTM_IMA_CONFIG_ABORTED_FE : Far end configuration abort state. This alarm is raised when the far end reports unacceptable configuration parameters. All other transmission alarms related to this signal are suppressed. Probable cause: The IMA group configuration is wrong (for example, the IMA versions are incompatible). INSTRUCTIONS: Check that the configurations at the near end and far end fit together (for example, IMA version and frame length). Change the configuration if necessary.
FAULT NAME : Far end group start-up on unit $U, IMA Group $IMAG FAULT ID : 61177: FTM_IMA_START_UP_FE MEANING : Far end group start-up. This alarm is raised when the far end indicates that it is in the start-up phase. The alarm is typically active only temporarily. Probable cause: The IMA group at the far end is not yet up and running. INSTRUCTIONS: If the alarm is on only temporarily, no action is needed. If the alarm stays active, check whether any other alarms related to this fault are on (such as problems on individual IMA links). If this is the case, follow the instructions for handling these alarms.
FAULT NAME FAULT ID MEANING
DN99580892
: Far end insufficient links on unit $U, IMA Group $IMAG : 61181: FTM_IMA_INSUFFICIENT_LINKS_FE : Far end insufficient links. The far-end IMA group reports that there are less IMA links in the far-end IMA group than required by the parameter Minimum number of IMA links. Probable causes: - IMA links within the IMA group are out of order - there are not enough IMA links configured for the IMA group - the value for the parameter Minimum number of links is set to be too high
Id:0900d805809d5c0d Confidential
223
7665 BASE STATION TRANSMISSION ALARM
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
INSTRUCTIONS: 1. Check the individual IMA links in the IMA group for problems. If needed, correct them. 2. Configure additional IMA links to the IMA group. 3. If feasible, reduce the minimum number of IMA links in the IMA group. 4. Check that the configurations at the near end and far end fit together. Change the configurations if necessary.
FAULT NAME FAULT ID MEANING
: Far-end receive link unusable on unit $U, interface $IF : 61176: FTM_IMA_RX_UNUSABLE : Far-end receive link unusable. The IMA link is not yet in an IMA group. The alarm is typically raised only temporarily during IMA configuration and disappears when the configuration has been completed. There are usually other IMA-related alarms active at the same time. Probable cause: IMA configuration is incomplete at the far-end interface. INSTRUCTIONS: Ensure that the far-end IMA link is configured to be part of an IMA group.
FAULT NAME FAULT ID MEANING
: Far-end transmit link unusable on unit $U, interface $IF : 61175: FTM_IMA_FE_TX_UNUSABLE : Far-end transmit link unusable. The IMA link is not yet in an IMA group. The alarm is typically raised only temporarily during IMA configuration and disappears when the configuration has been completed. There are usually other IMA-related alarms active at the same time. Probable cause: IMA configuration is incomplete. INSTRUCTIONS: Ensure that the IMA link is configured to be part of an IMA group.
FAULT NAME
: Five failed logins to FTM due to wrong credentials on if $IF FAULT ID : 61500: FTM_SECURITY MEANING : Five consecutive failed login attempts to the FTM have been performed due to wrong username or password. This Fault has to be generated for each affected interface as below. The interface names are (e.g. HTTP, XoH or NWI3UltraBTS only. INSTRUCTIONS: Check your username and password.
FAULT NAME FAULT ID MEANING
224
: Group timing mismatch on unit $U, IMA Group $IMAG : 61183: FTM_IMA_GR_TIMING_MISMATCH : Group timing mismatch. The far-end transmit clock mode is different from the near-end transmit clock mode. The traffic of the IMA group does not function properly. The IMA group might not be capable of carrying traffic on
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7665 BASE STATION TRANSMISSION ALARM
the IMA group referenced in the alarm text. Probable cause: Too large differential delay between the IMA links. INSTRUCTIONS: The IMA group reconfigures automatically. If the alarm remains active, do as follows: 1. Check the delay of the links. Special measurement equipment might be needed for this. Take appropriate actions to reduce the delay. 2. If the IMA link is used over a leased line, the problem might be located in the leased line network. In this case, the operator should be contacted.
FAULT NAME
: IMA link out of delay synchronization on unit $U, interface $IF FAULT ID : 61171: FTM_IMA_LODS MEANING : Link out of delay synchronisation. A LODS defect is reported when the link differential delay between the link and the other links in the group is higher than the tolerable link differential delay. Probable causes: - the configuration of the IMA group is incomplete or faulty - there is disturbance on the line - the differential delay of the IMA links belonging to one IMA group is too high INSTRUCTIONS: Do as follows for the interface referenced in the alarm text: 1. Verify that the IMA configuration of the near end and far end is correct. 2. Check the physical line for errors. 3. Check the delay of the IMA link in question. If necessary, select another suitable link.
FAULT NAME FAULT ID MEANING
: IMA remote failure indication on unit $U, interface $IF : 61172: FTM_IMA_RFI : Remote failure indication. An IMA-related remote defect has been detected. A Loss of IMA link (LIF) or Link out of delay synchronisation (LODS) alarm is active at the far end of the IMA link. Probable causes: - disturbance on the line - physical link defect - loss of IMA frame - loss of delay synchronisation INSTRUCTIONS: Follow the instructions for handling the alarms raised at the far end of the IMA link.
FAULT NAME
DN99580892
: IP address mismatch in dhcp allocated address on $IF $VID
Id:0900d805809d5c0d Confidential
225
7665 BASE STATION TRANSMISSION ALARM
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
FAULT ID MEANING
: 61609: DHCP_IP_ADDRESS_MISMATCH : BTS raises this alarm if IP address received from DHCP server is different from that configured for corresponding Transport network interface. The alarm is cleared when the correct IP address is received in DHCPACK. VID will be displayed in case of VLAN. INSTRUCTIONS: Check the DHCP server configuration in BTS. Check the physical connectivity between DHCP server and BTS/FTM.
FAULT NAME FAULT ID MEANING
: IPCP Failure : 61250: FTM_IPCP : The IPCP statemachine is in the Closed or Initial state and cannot reach the Opened state within 100 milliseconds. INSTRUCTIONS: Check the configuration of the far end
FAULT NAME FAULT ID MEANING
: Insufficient links on unit $U, IMA Group $IMAG : 61180: FTM_IMA_INSUFFICIENT_LINKS : Insufficient links. There are less operable IMA links in the IMA group than the minimum number of IMA links required. The IMA group referenced in the alarm text may not be able to carry all required traffic. Probable causes: - IMA links within the IMA group are out of order - there are not enough IMA links configured for the IMA group at the far end - the value for the parameter Minimum number of links is set to be too high INSTRUCTIONS: 1. Check the individual IMA links in the IMA group for problems. Correct them if necessary. 2. Configure additional IMA links to the IMA group. 3. If feasible, reduce the minimum number of IMA links in the IMA group. 4. Check that the configurations at near end and far end fit together. Change the configurations if necessary.
FAULT NAME
: Interface under test on unit $U, interface $IF for $T minutes FAULT ID : 61040: FTM_IF_TEST MEANING : A loopback has been configured by a management application. INSTRUCTIONS: Switch the loopback off or wait for the timeout to expire. This opens the loop which cancels the alarm.
FAULT NAME : LCP Failure on Interface $IF
226
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7665 BASE STATION TRANSMISSION ALARM
FAULT ID MEANING
: 61251: FTM_LCP : The alarm is raised if the LCP state machine on port $P is in the Closed or Initial state and cannot reach the Opened state within 100 milliseconds. INSTRUCTIONS: Check the configuration and corresponding alarms on the far end.
FAULT NAME FAULT ID MEANING
: LOCD on unit $U, interface $IF : 61057: FTM_LOCD : Loss of ATM cell delineation. The network interface receives frames whose ATM cells cannot be recognised. It is not possible to carry traffic on the interface referenced in the alarm text. Probable causes: - the far-end frames do not have ATM cell mapping - the far end does not insert idle cells - there are disturbances in the traffic of the physical transmission link in question INSTRUCTIONS: 1. Ensure that the far end is using ATM cell mapping. 2. Check whether any other alarms concerning the fault are on. If this is the case, follow the instructions on handling those alarms. 3. If the alarm is on only temporarily, no action is needed.
FAULT NAME FAULT ID MEANING
: LOF on unit $U, interface $IF : 61028: FTM_LOF : Loss of frame. It is not possible to carry traffic on the interface referenced in the alarm text. All other transmission alarms related to this signal are suppressed. Probable causes for STM-1/STS-3c interfaces: - the SDH/SONET interface receives frames that have an incorrect frame pattern (A1 and A2 bytes) - the configuration of the framing (STM-1 or STS-3c) on the far-end interface does not match the configuration on the interface referenced in the alarm text - too low an input level Probable cause for E1 interfaces: The interface at the far end is not configured to be a framed E1 interface. Probable cause for JT1 interfaces: The interface at the far end is not configured to be a JT1 interface. INSTRUCTIONS: E1 interfaces: Check that the interface type of the far-end interface is also configured to be a framed E1 interface. If this is not the case, reconfigure the interfaces so that they match each other. JT1 interfaces: Check that the interface type of the far-end interface is also configured to be a JT1 interface. If this is not the case, reconfigure the interfaces so that they match each other.
DN99580892
Id:0900d805809d5c0d Confidential
227
7665 BASE STATION TRANSMISSION ALARM
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
FAULT NAME FAULT ID MEANING
: LOMF on slot $U, interface $IF : 61150: FTM_LOMF : Loss of multiframe. The interface referenced in the alarm text has lost the multiframe alignment. Probable cause: the interface type has not been configured to meet the framing of the interface at the far end. For E1 interfaces, the configuration of the far-end node should be E1 Multiframe. INSTRUCTIONS: Check that the configured interface type matches the configured interface type of the far end. If this is the case, the problem is somewhere in the transmission network.
FAULT NAME FAULT ID MEANING
: LOP (Administrative Unit) on unit $U, interface $IF : 61105: FTM_LOP_AU : Loss of Pointer for the Administrative Unit. This alarm occurs when the SDH interface receives frames that have an incorrect Administrative Unit (AU) pointer. All other transmission alarms related to this administrative unit are suppressed. Probable cause: there are disturbances in the traffic on the link in question. INSTRUCTIONS: Check the intermediate VC-12 transmission network for alarms indicating the root cause and follow the instructions for handling these alarms.
FAULT NAME FAULT ID MEANING
: LOS on unit $U, Ethernet interface $IF : 61029: FTM_LOS : No signal is received on the interface referenced in the alarm text. All other transmission alarms related to this signal are suppressed. Probable causes for PDH interfaces: - a cable is cut or there is no cable connected to the interface - the electrical signal is excessively attenuated - the port at the connected far-end node is switched off - transmit and receive cables are mixed up Probable causes for Ethernet interfaces: - a cable is cut or there is no cable connected to the interface - the electrical signal is excessively attenuated - the port at the connected far end node is switched off INSTRUCTIONS: 1. Check that the cables are connected to the correct connectors. 2. Check that the interface at the far-end interface is switched on. 3. Check whether there are active alarms at the far end. If there are, follow the instructions for handling those
228
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7665 BASE STATION TRANSMISSION ALARM
alarms. 4. To verify that the hardware of the interface unit works correctly, connect a loop cable and check whether the alarm disappears.
FAULT NAME FAULT ID MEANING
: Licence missing , : 61400: FTM_LICENSE_MISSING : The feature referenced in the alarm text has been configured without installing a valid license. Probable cause: A valid license that would allow the operation of the feature is not available in the WBTS. This BTS fault can be displayed in the followings variants: License Missing 0000000598, E1, T1, JT1 interface License Missing 0000000616, IMA License Missing 0000000767, UBR+ for Iub User Plane License Missing 0000000768, ATM over Ethernet License Missing 0000001191, Timing Over Packet License Missing 0000001687, 2nd Flexbus interface License Missing 0000001688, Collocation Flexbus interface License Missing 0000001689, Flexbus Ethernet interface License Missing 0000001515, Synchronous Ethernet License Missing 0000001788, QoS aware Ethernet switching License Missing 0000001847, IP over ML-PPP on E1/T1/JT1 IF License Missing 0000001850, Ethernet OAM License Missing 0000001849, Fast IP Rerouting and OSPF License Missing 0000001905, IP Transport Network Measurement License Missing 0000001544, CES over PSN License Missing 0000001640, VLAN Traffic Differentiation License Missing 0000001848, IP Security for Iub in BTS License Missing 0000003876, Rapid Spanning Tree (RSTP) in the BTS License Missing 0000003906, Power over Ethernet INSTRUCTIONS: Download a valid license to the WBTS.
FAULT NAME FAULT ID MEANING
: Link OAM critical link event $E on unit $U, interface $F : 61077: Link OAM critical link event alarm : A Link OAM PDU containing a critical link event flag was received on the Ethernet interface. The alarm is raised with the first detection of the flag. The following critical link events are possible: - Critical Event: either an Errored Symbol Period Event, an Errored Frame Event an Errored Frame Period Event or an Errored Frame Seconds Summary Event was detected. - Dying Gasp: either the local or the remote peer has a fatal error and is about to restart. - Link Fault: the local peer has detected a physical link fault in receiving direction, for example a LOS. INSTRUCTIONS: 1)Inspect details of the type of the critical event through
DN99580892
Id:0900d805809d5c0d Confidential
229
7665 BASE STATION TRANSMISSION ALARM
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
online configuration management. 2)Check Link OAM state information of the interface. 3)Check cabling and network connections to the far end. 4)Check Ethernet interface configuration at local and remote side. 5)Insert a Link OAM loopback.
FAULT NAME : Link OAM link lost on unit $U, interface $F FAULT ID : 61076: Link OAM link lost alarm MEANING : On an interface for which the Link OAM functionality was switched on, no Link OAM PDUs were received during the period specified in configuration parameter linkLostTime (2..10 seconds, step 1 second). INSTRUCTIONS: 1)Check cabling and network connections to the far end. 2)Check Link OAM event- and Link OAM state information. 3)Check Ethernet interface configuration at local and remote side. 4)Insert a Link OAM loopback.
FAULT NAME
: Link OAM loopback inserted on unit $U, interface $F by $P peer FAULT ID : 61075: Link OAM loopback alarm MEANING : A loopback is requested for an Ethernet interface either locally at the BTS or the Link OAM client of the BTS is set into loopback mode by the remote Link OAM peer. INSTRUCTIONS: None.
FAULT NAME FAULT ID MEANING
: Link flapping fault : 61617: LINK_FLAPPING_FAULT : The link flapping alarm shall be raised on the Ethernet interface, if the link status changes twice (DOWN-->UP, UP-->DOWN) during the duration of the link flapping prevention timer. If the link goes up and down again during that flapping period, the link flapping timer shall be restarted. INSTRUCTIONS: Check link breaks.
FAULT NAME FAULT ID MEANING
230
: Loss of IMA frame on unit $U, interface $IF : 61170: FTM_IMA_LIF : Loss of an IMA frame. The loss of an IMA frame was detected in one link of the IMA group. The far-end IMA link is not part of an IMA group. All other transmission alarms related to this IMA link are suppressed. Probable causes:
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7665 BASE STATION TRANSMISSION ALARM
- the configuration of the IMA group is incomplete or faulty - there is disturbance on the line INSTRUCTIONS: Do as follows for the interface referenced in the alarm text: 1. Verify that the IMA configuration of the near end and far end is correct. 2. Check the physical line for errors.
FAULT NAME FAULT ID MEANING
: MLPPP Interface down : 61252: MLPPP_INTERFACE_DOWN : MLPPP interface is not operational when all the links in the bundle are not available. INSTRUCTIONS: All session down due to out of order or unplugged cable or interface down
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
MLPPP link Degrade 61622: MLPPP_LINKDEGRADE At least one of the sessions in MLPPP bundle has gone down. This alarm is because of FTM_IPCP or FTM_LCP alarms.
FAULT NAME
: No inserted or non-compliant SFP module on unit $U, interface $I FAULT ID : 61050: FTM_SFP MEANING : The SFP module detected in the interface connectors does not comply with the security requirements. INSTRUCTIONS: Insert a valid SFP module.
FAULT NAME FAULT ID MEANING
: OSPF neighbor $cause : 61085: OSPF neighbor down : The alarm notifies if the OSPF neighbor is down. The alarm cause can be: OSPF Neighbour down for destination address 1.2.3.4 or OSPF Neighbour up for destination address 1.2.3.4 INSTRUCTIONS: 1) Check cabling 2) Check the configuration of the static routes towards the neigbor
FAULT NAME FAULT ID MEANING
DN99580892
: PLM (High Order Path) on unit $U, interface $IF : 61108: FTM_PLM_HOP : Path Payload Label Mismatch on the High Order Path. The SDH interface receives frames on the VC-3/VC-4 that have a Path Payload Label that does not correspond to the "ATM" (Asynchronous Transfer Mode) signal. The path is not intended for ATM traffic transport. Probable cause: The Signal Type Identifier on the far end
Id:0900d805809d5c0d Confidential
231
7665 BASE STATION TRANSMISSION ALARM
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
interface has not been configured to be "ATM". INSTRUCTIONS: Ensure that the path payload label for the VC-3/VC-4 at the far end is configured to be "ATM".
FAULT NAME FAULT ID MEANING
: Poor Quality SSM on unit $UID $IF : 61624: SSM_POORQUALITY : This alarm is raised when the received SSM indicates lower clock quality (e.g. "do not use" or "EEC") than required. INSTRUCTIONS:
FAULT NAME FAULT ID MEANING
: Pseudowire $PW down in egress direction on unit $U : 61602: FTM_PWE_DOWN_EGRESS : A Pseudowire has been detected to be down in the egress direction by using the BFD function. The alarm is raised when the BFD message from the far end contains the diagnostic code 'Control Detection Time Expired' and the corresponding ingress alarm is not present. INSTRUCTIONS: Check that the Pseudowire configuration is complete.
FAULT NAME FAULT ID MEANING
: Pseudowire $PW down in ingress direction on unit $U. : 61601: FTM_PWE_DOWN_INGRESS : The Pseudowire has been detected to be down in the ingress direction by using the BFD function. INSTRUCTIONS: Check that the Pseudowire configuration is complete.
FAULT NAME FAULT ID MEANING
: RDI (High Order Path) on unit $U, interface $IF : 61109: FTM_RDI_HOP : Remote defect indication on the High Order Path (VC-3/VC-4). This alarm occurs when the equipment at the far end of a bidirectional VC-3/VC-4 connection has detected an error condition on the signal that it is receiving. The far-end equipment signals this remote defect in the signal that it transmits. The RDI indicates a serious fault in the received signal of the far-end equipment. Probable cause: The far end has active alarms on its receiving interface (such as LOS, LOF, TIM-RS, AIS-MS, AIS-AU, LOP-AU, TIM-HP, UNEQ-HP). INSTRUCTIONS: 1. Check the intermediate transmission network for alarms indicating the root cause and follow the instructions for handling these alarms. 2. To check the transmit hardware, connect a loop cable and check that LOS alarm is not raised.
FAULT NAME FAULT ID
232
: RDI (Multiplexer Section) on unit $U, interface $IF : 61103: FTM_RDI_MS
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7665 BASE STATION TRANSMISSION ALARM
MEANING
: Remote defect indication (RDI) on the Multiplexer Section (MS). This alarm occurs when the equipment at the far end of a bidirectional multiplexer section connection has detected an error condition on the signal that it is receiving. The RDI indicates a serious fault in the received signal of the far-end equipment. Probable cause: The far end has active alarms on its receiving interface (such as LOS, LOF, TIM-RS, AIS-MS, AIS-AU, LOP-AU). INSTRUCTIONS: 1. Check the intermediate transmission network for alarms indicating the root cause and follow the instructions for handling these alarms. 2. To check the transmit hardware, connect a loop cable and check that LOS alarm is not raised.
FAULT NAME FAULT ID MEANING
: RDI on unit $U, interface $IF : 61152: FTM_RDI : Remote defect indication. It is sent by the intermediate or the far end equipment, because it detects a serious fault in the received signal. Probable cause: The far end has a LOS, LOF or AIS alarm on its receiving interface. INSTRUCTIONS: 1. Check the intermediate transmission network for alarms indicating the root cause and follow the instructions for handling these alarms. 2. To check the transmit hardware, connect a loop cable and check that no alarms appear for this interface.
FAULT NAME FAULT ID MEANING
: Routing misconfiguration for application $a : 61073: ROUTING_MISCONFIGURATION : A routing misconfiguration was detected. A management-plane, control-plane, a synchronization-plane packet, or a CES-packet was sent over a network interface for
which it was not intended, as configured in the application IP addresses. Or a user-plane packet was sent over a network interface for which the 6 PHB priority queue scheduler was not activated by the operator. Since the actual egress network interface is selected based on the static routing table entries, a misconfiguration of the static routing table is suspected. INSTRUCTIONS: Correct the static routing table or change application IP addresses or assign the 6-PHB priority queue scheduler to another network interface.
FAULT NAME FAULT ID
DN99580892
: SSM Timed Out on unit $UID $IF : 61623: SSM_TIMEOUT
Id:0900d805809d5c0d Confidential
233
7665 BASE STATION TRANSMISSION ALARM
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
MEANING
: In case the incoming SSM is not anymore received for a certain time period (configured via 'ssmTimeout' parameter) this an alarm is raised. INSTRUCTIONS:
FAULT NAME
: STC connection to signalling peer not established on interface $ FAULT ID : 61260: FTM_STC_LINK_DOWN MEANING : The SSCOP link controlled by this STC is down. The alarm text specifies the slot, port, VPI and VCI number in question. Probable causes: - the peer (RNC) releases the connection - the link goes down because the peer (RNC) does not respond within the TIMER_NO_RESPONSE period. - the link was never established - problem on the ATM layer - problem on the physical layer - incomplete or faulty configuration of AAL2 in the RNC INSTRUCTIONS: 1. Check that there are no other active alarms on the physical or ATM layer. 2. Check that the RNC is up and running. 3. Check the AAL2 configuration. For example, make sure that the VPs/VCs used for AAL2 signalling in the RNC and WBTS match.
FAULT NAME FAULT ID MEANING
: Synchronisation lost : 61058: FTM_SYNC_LOSS : Primary and secondary timing source lost. The WBTS is running on internal clock or in hold-over mode and no timing signal is sent. The first and second synchronisation sources from the configured priority list are unavailable. On failure, the WBTS switches automatically to the next clock source in the priority list. Probable cause: The transmission links selected for clock source are faulty. The reason can be alarms on the interfaces (for example, LOS, LOF or AIS). INSTRUCTIONS: Use the BTS Site Manager to check which interfaces have been configured as synchronization sources. For the PDH interfaces, do as follows: 1. Check that the cables are connected to the correct connectors. 2. Check whether the interface at the far end is switched on. 3. Check whether there are active alarms at the far end. If there are, follow the instructions on handling those alarms. 4. To verify that the hardware of the interface unit works
234
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7665 BASE STATION TRANSMISSION ALARM
correctly, connect a loop cable and check whether the alarm disappears.
FAULT NAME : FAULT ID : MEANING : INSTRUCTIONS:
TWAMP session down for reason: $r 61084: TWAMP SESSION DOWN A TWAMP session has gone down. Check the cabling towards the TWAMP responder. Check the configuration of the TWAMP responder.
FAULT NAME FAULT ID MEANING
: Timing source lost on unit $U, master $IF : 61059: FTM_TIMING_SOURCE_LOS : Primary or secondary timing source is lost. One of the synchronisation sources in the configured priority list is unavailable. If the primary clock source has been lost, a switch to the secondary source has occurred. If the secondary clock source has been lost, the WBTS will switch to the internal clock in case the primary clock source fails. Probable cause: The transmission link selected for the clock source is faulty. The reason can be alarms on the interface (for example, LOS, LOF, AIS or EBER). INSTRUCTIONS: Use BTS Site Manager to check which interfaces have been configured as synchronization sources. For the PDH interfaces, do as follows: 1. Check that the cables are connected to the correct connectors. 2. Check whether the interface at the far end is switched on. 3. Check whether there are active alarms at the far end. If there are, follow the instructions on handling those alarms. 4. To verify that the hardware of the interface unit works correctly, connect a loop cable and check whether the alarm disappears.
FAULT NAME FAULT ID MEANING
: ToP master service $IP unusable : 61631: TOP_MASTER_UNUSABLE : The reference clock monitoring has detected a loss of ToP reference clock signal received from the master clock behind $IP. - The eNB does not receive a reply from ToP Master within a certain time (5 sec) upon it has sent a sync request message - The eNB receives from ToP Master a granted message rates (sync message rate, delay message rate), that does not match the requested rate by eNB INSTRUCTIONS: Check the cable connectivity. Check the TOP configuration.
DN99580892
Id:0900d805809d5c0d Confidential
235
7665 BASE STATION TRANSMISSION ALARM
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
FAULT NAME FAULT ID MEANING
: Transport module missing: $unit : 61201: TRANSPORT_MODULE_MISSING : Unit missing. The slot has been configured to hold a unit but the plug-in unit is not physically present in the slot. Probable causes: - the unit has been configured but not detected - the unit is broken and therefore not detected NOTE: unit variable should be replaced by appropriate HW names configured (unitTypeConfigured) during runtime reporting. INSTRUCTIONS: Replacing faulty hardware: 1. Re-Plug in the expected transport unit referenced in the alarm text. 2. In case there is a unit present in the slot, remove it from the slot and plug it back in. If the unit is still not recognised and the alarm remains, replace the faulty unit with a new one. De-commissioning previously commissioned hardware: 1. Re-commission to remove the hardware unit referenced in the alarm text. NOTE: Before re-commissioning, the hardware unit must not be present in the slot.
FAULT NAME FAULT ID MEANING
: UNEQ (High Order Path) on unit $U, interface $IF : 61107: FTM_UNEQ_HOP : High Order Path Unequipped. The path signal label byte (C2) and the path trace byte (J1), and BIP-8 byte (B3) in the SDH path overhead (POH) all have the value zero. The path is unusable for traffic transport. Probable cause: the unequipped VC-3/VC-4 comes from a VC-level cross-connection node and the VC-3/VC-4 is not connected anywhere in that node. INSTRUCTIONS: 1. Check the configuration and ensure that the cross-connections between the nodes have been properly configured for transporting traffic. 2. Ensure that the Path Payload Label for the VC-3/VC-4 at the far end is configured to be "ATM". 3. Follow the signal in the network and check whether any other alarms concerning the fault are active. If this is the case, follow the instructions for handling those alarms.
FAULT NAME FAULT ID MEANING
236
: Vendor BTS certificate due to expire : 61616: VENDOR_CERTIFICATE_EXPIRING : The BTS raises a "Vendor BTS certificate due to expire"
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7665 BASE STATION TRANSMISSION ALARM
alarm when the Vendor BTS certificate is about to expire. The period of notificaton in advance is configurable and the same as for the CA certificate expiry described in WBTS_SEC_46333 1 day ... 4999 days with default 1825 days. INSTRUCTIONS: Check the vendor BTS certificate expiry date and extend it. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
DN99580892
Id:0900d805809d5c0d Confidential
237
7740 BEATING WCDMA BTS ALARM
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
37 7740 BEATING WCDMA BTS ALARM Meaning The same radio network alarm has changed its alarm state (start/cancel) 20 times consecutively, always during informing or cancelling delay, and has thus been filtered by the alarm system. The same radio network object is the object of both: the alarm in question and the beating alarm that caused it. Supplementary information fields 1
the alarm number of the beating BTS alarm
2-15 if the beating alarm has any additional information, it is indicated here. Additional information is cut after 14 bytes and it is represented in hexadecimal format. Instructions Correct the fault that caused the original beating alarm. You can find the number of that alarm in Supplementary information field 1. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
238
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7750 FAILURE IN WCDMA WBTS O&M CONNECTION
38 7750 FAILURE IN WCDMA WBTS O&M CONNECTION Meaning This alarm indicates that a failure has occurred in WBTS O&M connection. The problem is related to Iub connection between controller and WBTS. From controller point of view the actual reason for the failure is either in transmission network between controller and WBTS, in internal communication of controller applications or in WBTS configuration. This alarm is set by controller in the following situations: 1) WBTS has closed the O&M connection. 2) WBTS O&M connection supervision message has not arrived within expected time 3) there is a problem in transmission network between controller and WBTS 4) a WBTS id conflict has been detected in the network As a consequence of this alarm, the availability of WBTS O&M functionality may be limited. User initiated or automatic O&M tasks (e.g. SW download, HW configuration request and WBTS restart) cannot be performed in case of Iub O&M connection problem. It is also not possible for the WBTS to report its alarms to controller. This alarm does not indicate a failure in WBTS user plane links. The states of the user plane links can be checked using OMS Topology Browser. Supplementary information fields 1
reason of the alarm 1 = failure in the controller - WBTS connection 2 = WBTS id conflict
2
error code is received from IUB O&M connection. This field is significant only if the value of 1st field is 1 You can check its meaning from the document General Error Messages of System, Supplementary References Instructions
Error reason (field 1) indicates which part of the connection the problem is located.
DN99580892
Id:0900d805809d5c0d Confidential
239
7750 FAILURE IN WCDMA WBTS O&M CONNECTION
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
Error code (field 2) indicates what caused the problem if the error reason (field 1) value is 1. Error reason = 1, failure in the WBTS connection Error code: 14005 = CONNECTION RESET BY PEER WBTS has closed the connection. Wait until WBTS opens a new connection and system cancels the alarm. If connection does not recover in a couple of minutes, check that WBTS is configured correctly to controller and to Network.
Error codes: 13960 = BAD FILE DESCRIPTOR 13964 = PERMISSION DENIED 13965 = BAD ADDRESS(EFAULT) 13986 = RESOURCE TEMPORARILY UNAVAILABLE 13989 = SOCKET OPERATION ON NON-SOCKET 13991 = MESSAGE TOO LONG 14006 = NO BUFFER SPACE AVAILABLE 14008 = SOCKET IS NOT CONNECTED 14016 = NO ROUTE TO HOST 14608 = CONNECTION NOT EXIST Controller attempted to send an O&M message towards the WBTS, but the connection does not exist in the controller (code 14608) or some error occurred in TCP layer when message sending was attempted. Check that WBTS is configured correctly to controller and to Network. If configuration is ok, wait until WBTS opens a new connection and system cancels the alarm.
Error code: 154 = TIME LIMIT EXCEEDED IN MESSAGE WAITING WBTS supervision timer has expired. Connection is closed and controller is waiting for a new O&M connection opening from WBTS. Wait until system cancels the alarm.
Error 14001 14011 14015
codes: = NETWORK IS DOWN = OPERATION TIMED OUT = HOST IS DOWN
There are problems in transmission network between controller
240
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7750 FAILURE IN WCDMA WBTS O&M CONNECTION
and WBTS. Try to connect to BTS using BTS Site Manager and deduce the source of the problem with provided information. Error code: 10149 = SWITCHOVER This error code is used if OMU unit switchover has occurred in the RNC and O&M connection to the WBTS has been closed because of that. The WBTS O&M connections are always handled by the OMU unit in WO-EX state so in switchover case the connections are closed. Wait until WBTS opens the O&M connection again and system cancels this alarm. Any other error code: Contact the local Nokia Siemens Networks representative.
Error reason = 2, WBTS id conflict More than one WBTS has been configured with the same id. Error code: 255 = UNSUCCESSFUL An O&M connection for a WBTS id already exists in the RNC. This alarm was set because the same WBTS id was used in new O&M connection establishment from a different IP address that already existing connection was established from. This happens if several WBTS have been configured with the same WBTS id under the same RNC. The supplementary text of alarm gives IP address of the conflicting WBTS. Use BTS Manager to connect the conflicting WBTS with its IP, configure it with a different id. Depending on the WBTS release, the reconfiguration may need to be done using AXC Manager. Cancel the alarm manually after resolving the WBTS id conflict. Cancelling Do not cancel the alarm with error reason 1. The system cancels the alarm automatically when the fault has been corrected. The alarm with error reason 2 must be canceled manually. Error reason = 1 Alarm will be canceled when BTS O&M connection is working again.
DN99580892
Id:0900d805809d5c0d Confidential
241
7750 FAILURE IN WCDMA WBTS O&M CONNECTION
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
Error reason = 2 Alarm must be canceled manually with MML command AAN or with Fault Management application in RNC Element Manager after conflicting WBTS id situation is corrected.
242
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7761 RNW O&M SCENARIO FAILURE
39 7761 RNW O&M SCENARIO FAILURE Meaning The alarm indicates a failure in some of the following scenarios: - Controller restart - WBTS initialization or WBTS reset - cell initialization, activation or blocking - forced handover - modification of configuration data - pid data updating (storing the process id of the telecom process which is responsible of managing the WBTS/WCELL in question) - WBTS capability information updating - Connection configuration (COCO(IPA-RNC))/IPNB management - Audit handling - Common channel supervision - Common measurement supervision - WBTS recovery (system initiated BTS restart operation) - Iu service barring - Cell deletion - Dedicated measurement initiation These scenarios can be a consequence of either user operation or operation performed by the system. User operation can be, for example, WCEL creation with Element Manager or by plan. Operations performed by the system are in most cases related to recovery operations, for example common channel supervision. In general, all failures cause the cell(s) to be blocked and hence unavailable to traffic. Failure in cell blocking can lead to erroneous cell state information in the controller. Failure in WBTS capability updating or pid updating can cause incorrect WBTS capability data to be used in the controller and thus problems in signalling or actual calls. Failure in User plane configuration (AAL2 path unblocking) causes a situation where the User plane traffic cannot be transferred in the corresponding AAL2 VCC. Supplementary information fields 1
reason for the failure 01 02 03 04 05
DN99580892
WBTS reservation has failed Configuration data updating has failed Inactivation of the cell has failed Activation of the cell has failed Common channel deletion has failed
Id:0900d805809d5c0d Confidential
243
7761 RNW O&M SCENARIO FAILURE
06 07 08 09 0A 0B 0E 11 12 13 14 15 16 18 19 20 21 2
244
Common channel creation has failed BCCH information updating has failed WBTS capability information was not received Forced handover request was not accepted WBTS capability information update has failed AAL2 path unblocking has failed Unknown NBAP interface type Audit has failed, only 3GPP Iub Cell setup procedure has failed, only 3GPP Iub Cell deletion procedure has failed, only 3GPP Iub Common measurement initiation has failed, only 3GPP Iub RRI measurement initiation has failed, only 3GPP Iub Cell reconfiguration procedure has failed, only 3GPP Iub Common or RRI measurement termination failed, only 3GPP Iub Cell barring has failed COCO (IPA-RNC)/IPNB disconnect has failed COCO (IPA-RNC)/IPNB connect has failed
scenario that was being carried out when the failure occurred 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 81 82 83 84 8D 8E 8F 90 91 92 93 94
3
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
Not specified WBTS initialization, Nokia Siemens Networks Iub Cell unlocking, Nokia Siemens Networks Iub Configuration data modification, Nokia Siemens Networks Iub Controller restart, Nokia Siemens Networks Iub Local cell resource state change Forced handover WBTS reset initiation from controller WBTS capability information update Pid update Connection configuration management Audit handling, 3GPP Iub CCH Supervision WBTS recovery Iu service barring Cell deletion, 3GPP Iub WBTS initialization, 3GPP Iub Cell unlocking, 3GPP Iub Cell reconfiguration, 3GPP Iub controller restart, 3GPP Iub WBTS restart, 3GPP Iub WBTS cell block, 3GPP Iub WBTS cell unblock, 3GPP Iub Resource status indication handling, 3GPP Iub Common measurement supervision Dedicated measurement initiation Cell activation due to power save Cell shutdown due to power save
general error code of the system
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7761 RNW O&M SCENARIO FAILURE
You can check its meaning with a command of the service terminal extension MRS (see Service Terminal Essentials, Maintenance Manual) or from the document General Error Messages of System, Supplementary References 4
ATM interface identifier of network external or internal interface. This field is significant only in case of User plane configuration fault. FFFF
5
virtual path identifier. This field is significant only in case of User plane configuration fault. FFFF
6
Not specified
Not specified
virtual channel identifier. This field is significant only in case of User plane configuration fault. 0
Not specified Instructions
This instruction contains five main steps. The first four steps are specific to certain failure situations. The last step is a general operating procedure for all other failures indicated by this alarm. It is also a default procedure to be performed if instructions given in previous steps do not solve the problem. Abbreviation SIF refers to supplementary information field. Step 1: In case the value of SIF 2 (scenario) is 07 (WBTS reset): - First, verify using Element Manager that WBTS id is valid in the system and COCO (IPA-RNC) is connected to WBTS. - Check also if alarm 7750 FAILURE IN WCDMA BTS O&M CONNECTION is active for this WBTS. If it is active indicating that there is something wrong with WBTS O&M connection (Iub), then reset command cannot be sent from RNC to WBTS. -> If WBTS O&M connection is OK, retry to reset WBTS with Element Manager. -> If WBTS O&M connection between RNC and WBTS is not OK, try to solve the situation with BTS Manager by examining the WBTS alarms and logs. Step 2: In case the value of SIF 2 is 0A (Connection configuration management), and the value of the SIF 1 is 0B (AAL2 path unblocking has failed): - Check the configuration of the corresponding WBTS node using BTS Manager. It should match the configuration of the RNC. - Check that ATM/IP resources related to COCO (IPA-RNC) are
DN99580892
Id:0900d805809d5c0d Confidential
245
7761 RNW O&M SCENARIO FAILURE
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
not locked. Locked ATM/IP resources prevent the connection configuration operations. IPA-RNC: - Use MML command ZLAI to print ATM interface information and MML command ZLCI to print VP/VC information (if ATM layer information is given by the user in controller Element Manager). - Unlock the ATM-interface with MML command ZLAS and VP/VC with MML command ZLCS if needed. - If this alarm was generated due to user initiated action, for example COCO (IPA-RNC) creation, try to perform the operation again. Multi-controller RNC or Flexi Direct RNC: Commands "fshclish > show ipnb" can be used to see the IPNB configurations. - If configuration is correct and ATM/IP resources are unlocked, act according to the general operating instructions in step 3 below. Step 3: In case the SIF 2 value is 0D (WBTS recovery) and the value of the SIF 1 is 20 (COCO(IPA-RNC)/IPNB disconnect has failed) or 21 (COCO (IPA-RNC)/IPNB connect has failed): - In case of COCO(IPA-RNC)/IPNB disconnect failure, disconnect the COCO/IPNB manually using Element Manager by removing the WBTS id from the corresponding COCO(IPA-RNC)/IPNB object. Wait at least for 15 seconds and connect the COCO(IPA-RNC) again by restoring the WBTS id to COCO (IPA-RNC)/IPNB object. - In case of COCO(IPA-RNC)/IPNB connect failure, try to connect the COCO(IPA-RNC)/IPNB again to the WBTS using Element Manager. In IPA-RNC if COCO id related to this WBTS is not known, the related COCO id can be found from OMU computer log by searching for process family 50B writings (ZGSC:,50B;) that contain also the WBTS id that this alarm is targeted to. In Multi-controller RNC/Flexi Direct RNC the family 50B logs can be found from location "/srv/Log/log/" in the product. This contains the detailed logs for all the families. Step 4: In case the SIF 2 value is 92 (Dedicated measurement initiation): - Alarm 7778, WCDMA BTS DEDICATED MEASUREMENT FAILURE should be active. Follow the instructions given for that alarm. Step 5: General operation instructions for all other failure reasons: Wait a couple of minutes, system tries to recover from the problem by retrying the failed operation again and the alarm
246
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7761 RNW O&M SCENARIO FAILURE
may be cancelled automatically. In case the alarm is not cancelled due to system recovery while waiting, try to lock and then unlock the cell with controller Element Browser manually. This causes the system to try to clear possible hanging cell related resources and then recreate (init) them. In case the alarm is still active after lock/unlock cell operation, some of the following actions can be tried (each of these causes the WBTS to be unavailable during the operation). These operations clear and again init the BTS related resources: - Reset the WBTS with Element Manager, or - Reform the connection between WBTS and COCO(IPA-RNC) by first disconnecting the COCO (IPA-RNC) and then reconnecting it (this can be done by changing the used COCO(IPA-RNC)id in the WBTS with controller Element Manager) or block/unblock the BTS with BTS element manager. If the alarm still remains active after the steps above, and no obvious reason behind it can be found, collect at least the following logs and contact the local Nokia Siemens Networks representative: IPA-RNC: - OMU computer log, - message monitoring from OMU (families 50B, 4FA, 4EE and 4EF) and serving ICSU (check serving ICSU from COCO(IPA-RNC) (data in Element Manager, monitor families 4FE, 4FB, 4FD, 4B7) during BTS reset Also controller reset might help the situation if it is possible to be performed. More information about the exact failure reason can be found by examining the supplementary info field 3 (error code). You can check its meaning with a command of the service terminal extension MRS (see Service Terminal Essentials, Maintenance Manual) or from the document General Error Messages of System, Supplementary References. In many cases there is also more information in OMU computer log. It can be studied with MML-command ZDDE::"ZGSC"; Multi-controller RNC/Flexi Direct RNC: The detailed logs of all families can be collected from "/srv/Log/log/" location in the product.
DN99580892
Id:0900d805809d5c0d Confidential
247
7761 RNW O&M SCENARIO FAILURE
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
248
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7762 RNW DATABASE OPERATION FAILURE
40 7762 RNW DATABASE OPERATION FAILURE Meaning RNW database operation has failed. This reading or writing operation was tried for some of the following scenarios: - WBTS reset - WBTS initialization - Cell activation - Cell blocking - Cell unblocking - Modification of configuration data - Storing the pids - Storing the WBTS capability information - Storing cch parameters - Cell unlocking - Cell reconfiguration - Controller restart - Audit handling - Iu service barring - Resource status indication handling - Common measurement supervision Depending on the scenario, this failure has led to a situation where cell state could not be modified from blocked to working state or vice versa in controller or it was not possible to send configuration data to WBTS. Failure in pid updating can cause trouble to other O&M scenarios where that information is needed, and failure in WBTS capability updating or CCH parameter updating can cause inconsistent data to be used in controller and thus problems in signalling or in actual calls. Supplementary information fields 1
specifies if the error occurred during reading from or writing to database 01 02
2
Reading failure Writing failure
reason of the failure 00 01 02 03 04 05 11 12
DN99580892
Not specified Failure at initialization Configuration data Deactivation of the cell has failed Activation of the cell has failed NBAP-link state updating failure Failure in cell setup, 3GPP Iub Failure in cell reconfiguration, 3GPP Iub
Id:0900d805809d5c0d Confidential
249
7762 RNW DATABASE OPERATION FAILURE
3
scenario that was being carried out when the failure occurred 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 81 82 83 84 8D 8E 8F 90 91
4
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
WBTS initialization Cell unlocking Configuration data modification Controller restart Local cell resource state change Forced handover WBTS reset WBTS capability information update Pid update CCH data update Link failure/link failure cancel CCH Supervision Audit handling, 3GPP Iub Iu service barring WBTS initialization, 3GPP Iub Cell unlocking, 3GPP Iub Cell reconfiguration, 3GPP Iub controller restart, 3GPP Iub WBTS restart, 3GPP Iub WBTS cell block, 3GPP Iub WBTS cell unblock, 3GPP Iub Resource status indication handling, 3GPP Iub Common measurement supervision
general error code of the system. You can check its meaning with a command of the service terminal extension MRS (see Service Terminal Essentials, Maintenance Manual) or from the document General Error Messages of System, Supplementary References Instructions
IPA-RNC: At first, check the functionality of Radio Network database with the following MML-commands: ZDBS:RAQUEL,0; State of database should be normal and memory (and disk) updates not prevented. If updates are prevented, you can resume them with command ZDBR:RAQUEL,0:; If database state is "waiting for dumping" or "dumping", database should return to normal state automatically after dumping is ready. Also status of the disk updating system can be checked with MML-command ZDBD:OMU; Line "RAQUEL" specifies the state of Radio Network database. If database state is working (or becomes working after a while), do as follows:
250
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7762 RNW DATABASE OPERATION FAILURE
Try to lock the cell and then unlock it with Element Manager. If this does not clear the alarm, try WBTS reset. If database state remains abnormal for long time or the alarm appears constantly for several WBTSs and cells, contact the local Nokia Siemens Networks representative. Also controller reset might help if it is possible to perform it. More information about the exact failure reason can be found by examining the supplementary info field 4 (error code). In many cases there is also more information in OMU computer log. IPA-RNC: It can be studied with MML-command ZDDE::"ZGSC"; Multi-Controller RNC or Flexi Direct RNC: Logs can be collected and studied from location "/srv/Log/log/"in the product. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
DN99580892
Id:0900d805809d5c0d Confidential
251
7771 WCDMA CELL OUT OF USE
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
41 7771 WCDMA CELL OUT OF USE Meaning The alarm indicates some reason, and it only when a cell is meaning that a user alarm.
that an unlocked WCDMA cell has been blocked for cannot transmit any traffic. This alarm is set moved to the blocked state by the system, initiated state change does not cause this
The alarm is set when one of the following situations occurs: 1. WCEL state is changed from - WO -> BL(B), bl- WBTS - WO -> BL(S), bl- system failure - WO -> BL(I), bl- init - WO -> BL(L), bl- C-NBAP link failure - WO -> BL(M), bl- Common measurement failure - WO -> BL(Ub), bl- Blocked by user locally from WBTS It is possible that the WCEL state changes first from WO to BL(H) (bl - shutting down) and only after that to one of the above mentioned states. This alarm is not set when the WCEL state changes from WO to BL(H), but it is set when the BL(H) state is replaced by one of the above mentioned blocked states. 2. WCEL is unlocked and the COCO(IPA-RNC)/IPNB connection operation has been performed, but the state of the WCEL does not change to WO. 3. COCO(IPA-RNC)/IPNB connection operation has been performed, the WCEL has been unlocked, but the state of the WCEL does not change to WO. 4. An incorrect Local Cell Resource id has been given to this cell. Such a Local Cell does not exist in the WBTS. 5. The NEType indicated by the BTS and the NBAP Communication Mode configured in the controller for the WBTS object do not match. The alarm is cancelled automatically when the state of the WCEL changes back to WO or when the cell is locked by the user. Supplementary information fields 1
252
indicates the state that the WCEL was changed into and what caused the alarm to be set. Full information about the current cell state is available in the Element Manager. The meanings of the possible values and the corresponding GUI abbreviations are:
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
0008: 0020: 0040: 0080: 0100: 0200: 0400: 2
bl bl bl bl bl bl bl
-
7771 WCDMA CELL OUT OF USE
WBTS (WBTS has sent disabled state information) (B) system failure (S) init (also during resets) (I) C-NBAP-link failure (L) Common measurement failure (M) Blocked by user locally from WBTS (Ub) Blocked because cell does not exist in WBTS (N)
general error code of the system. You can check its meaning from General Error Messages of System. Instructions
First task: wait for 5 minutes. Typically, there is still some recovery operation ongoing. The alarm gets cancelled if the recovery is successful. If the automatic recovery does not correct the situation, follow these steps: 1. If the blocking reason in the supplementary information field 1 (WCEL state) is 0008 (BL(B)) or 0200 (BL(Ub)), check the WBTS alarm that is related to this WCEL, and follow the operating instructions there. 2. If the blocking reason in the supplementary information field 1 (WCEL state) is 0400 (BL(N)), an incorrect Local Cell Resource id has been given to this cell. Such Local Cell does not exist in the WBTS. The cell data must be corrected and, after that, a WBTS reset is required to remove the problem. 3. If the blocking reason in the supplementary information field 1 (WCEL state) is 0040 (BL(I)) and the value in the supplementary information field 2 (Error code) is 4434 (nbapcmode_netype_mismatch_ec), the NBAP Communication Mode and the Netype do not match. Check the WBTS alarm related to this WCEL, and follow its operating instructions. 4. In case there are no alarms targeted to the WCEL, try to lock and then unlock the cell manually with the controller Object Browser. This way the system tries to clear the possible hanging cell related resources and then recreate (init) them. 5. If the alarm is not cancelled by the lock/unlock cell operation, you can try some of the following actions (the WBTS is unavailable during these operations). These operations first clear and then recreate the BTS related resources: - reset the WBTS with the Element Manager, or - reform the connection between the WBTS and the COCO(IPA-RNC) /IPNB by first disconnecting the COCO(IPA-RNC)/IPNB and then
DN99580892
Id:0900d805809d5c0d Confidential
253
7771 WCDMA CELL OUT OF USE
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
reconnecting it (this can be done by changing the used COCO(IPA-RNC)/IPNB id in the WBTS with the Element Manager), or - block/unblock the BTS with the BTS element manager. If the alarm is still active after the above operations have been performed, and no obvious reason behind it can be found, collect at least the following logs and contact the local Nokia Siemens Networks representative: IPA-RNC: - OMU computer log (service terminal command ZGSC), - message monitoring from OMU (families 50B, 4FA, 4EE and 4EF) and the serving ICSU (check the serving ICSU from the COCO (IPA-RNC) data in the Element Manager, monitor families 4FE, 4FB, 4FD, 4B7) during the BTS reset. Multi-Controller RNC or Flexi Direct RNC: Logs can be collected and studied from location "/srv/Log/log/"in the product. Also a controller reset can help if it is possible to perform it. More information about the exact failure reason can be found by examining the supplementary information field 2 (error code). You can check its meaning with a command of the service terminal extension MRS (see Service Terminal Essentials), or from the document General Error Messages of System. In many cases there is also more information in the OMU computer log. IPA-RNC: It can be studied with MML-command ZDDE::"ZGSC"; Multi-Controller RNC or Flexi Direct RNC: Logs can be collected and studied from location "/srv/Log/log/"in the product: Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected. The alarm is cancelled by system if the cell in question starts to work again or it is locked by user.
254
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7772 HSDPA CONFIGURATION FAILED
42 7772 HSDPA CONFIGURATION FAILED Meaning This alarm indicates that there has been an error when controller has requested configuration or reconfiguration of HSDPA channels to BTS via Physical Shared Channel Reconfiguration procedure. The causes which result in this alarm are: - a problem in transmission network between controller and BTS - BTS has rejected the configuration or reconfiguration of HSDPA channels - Controller is unable to send the HSDPA configuration to BTS because of controller internal problems (for example congestion in Iub interface) Location and the nature of the failure can be determined from the supplementary information fields of this alarm. The consequence of this alarm depends on the HSDPA configuration phase. - In case the initial configuration of HSDPA channels fails, the effect is that HSDPA connections cannot be used in this particular cell at all. In this case also the HSUPA connections are unavailable if HSUPA is enabled in the cell. - In case of reconfiguration of HSDPA channels the effect is that the cell may not work with the intended HSDPA parameters. Supplementary information fields 1
reason of the alarm Possible 01 = 02 = 03 =
values: No reply from BTS BTS rejects the configuration Controller internal error
2
computer unit where this alarm is generated from
3
index of the alarming unit
4
more detailed cause in case the BTS rejects the configuration Possible 00 = 01 = 02 = 03 =
5
values: Error in radio network configuration Error in transport layer Error in NBAP protocol layer Miscellaneous
possible values sent by the BTS, value meaning depends on the cause that is given in 4th supplementary information field:
DN99580892
Id:0900d805809d5c0d Confidential
255
7772 HSDPA CONFIGURATION FAILED
00 01 06 09
= = = =
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
Unknown cell ID (RNW configuration) Cell not available (RNW configuration) Node B resources unavailable (RNW configuration) Requested configuration not supported (RNW configuration)
03 = Message Not Compatible With Receiver State (Protocol) 00 = Control processing overload (Misc) 03 = Not enough user plane processing resources (Misc) 04 = Unspecified (Misc) 6
more detailed cause in case the value of the 1st supplementary information field is 3 ("controller Internal error"). Possible values: 306 = Internal waiting timer expired in BTS Resource Manager 328 = BTS overloaded 402 = Wrong BTS ID 404 = Wrong cell ID 420 = No free DL Spreading Codes available for HSDPA 501 = Internal waiting timer expired in NBAP interface 504 = Encoding failed in NBAP interface 505 = Decoding failed in NBAP interface 506 = Parallel procedure not allowed 507 = Unit switchover 508 = State conflict 510 = Table full 529 = NBAP link down
7
phase of HSDPA configuration 01 = Initial HSDPA configuration 02 = Reconfiguration of HSDPA 03 = PWSM HSPA05 reconfiguration failure Instructions
Check first the nature of the problem. The 7th supplementary information field value indicates the phase in which the problem has occurred: 01: Initial HSDPA configuration The problem has occurred during initial HSDPA setup to a cell. The effect of this is that HSDPA cannot be used in the cell. 02: Reconfiguration of HSDPA The problem has occurred during HSDPA reconfiguration to a cell. The effect is that the HSDPA may not work with the intended parameters. In this case it is recommended that HSDPA is disabled and enabled
256
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7772 HSDPA CONFIGURATION FAILED
in the cell to confirm that proper parameters are taken into use. This action requires cell locking. 03: PWSM HSPA05 reconfiguration failure The problem has occurred during HSDPA reconfiguration to a cell when Power Saving Mode For BTS (PWSM) feature has been making HSPA05 reconfiguration. HSPA05 reconfiguration has been stopped and no cell deletion or activation by PWSM feature will be done. In this case it is recommended to disable PWSM feature. Do cell lock/unlock to recover cell HSDPA parameters and state. If cell is not recovered using lock/unlock operation, a BTS restart can be attempted using Element Manager or BTS Site Manager. The first supplementary information field value indicates the main reason for the problem. 01: No reply from WBTS Problem may reside somewhere in transmission network to BTS. Check if there are other active alarms for the WBTS object and follow the instructions given for those alarms. If there are no apparent problems shown via other alarms, check the type of network problem with following instructions: Precondition for Physical Shared Channel Reconfiguration procedure is that the C-NBAP link to WBTS is working. Check the state of C-NBAP link of this WBTS object from Element Manager main dialog. If the C-NBAP link works, the problem may reside in the BTS. Check the BTS configuration and logs using BTS Manager. If the C-NBAP link does not work, check the success of PING between controller and BTS. Successful PING tells that the BTS is up and running: MML command: ZQRX (IPA-RNC) Normal Ping command : Multi-controller RNC/Flexi Direct RNC If ping does not succeed, then the problem is in lower level of the transmission network. Check physical connections in the network. If ping succeeds, then the problem is in application level. In many cases there is also more information in OMU computer log. IPA-RNC : Logs can be studied with MML-command ZDDE::"ZGSC"; Multi-Controller RNC or Flexi Direct RNC: Logs can be collected and studied from location
DN99580892
Id:0900d805809d5c0d Confidential
257
7772 HSDPA CONFIGURATION FAILED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
"/srv/Log/log/" in the product.
02: BTS rejects the configuration Check that the concerned BTS is in working state using Element Manager. If the working state of the BTS is OK, check that the BTS has correct HW configuration so that HSDPA can be supported (WSPC cards) using BTS Manager. If the working state of the BTS and the BTS HW configuration are OK but this fault still occurs, contact the local Nokia Siemens Networks representative. In case the fault is related to RNW configuration (based on 4th and 5th alarm supplementary information fields of this alarm), check the configuration of this WBTS object in controller using Element Manager, and the configuration in BTS using BTS Manager. Check also if other alarms are active targeted to this same WBTS object. If there are active alarms, proceed according to instructions given for those alarms. If the fault cannot be resolved by correcting the configuration or other BTS alarms, contact the local Nokia Siemens Networks representative. 03: Controller internal error An internal error in controller has occurred during Physical Shared Channel Configuration procedure. If the 6th supplementary information field of this alarm has a value 306, 420, 501, 504, 505, 506, 508, 510 or 529, the situation may be resolved by locking and unlocking the cell. This operation cancels the alarm and triggers the Physical Shared Channel Reconfiguration procedure again. If the problem was only temporary, the alarm should not appear again. If the alarm appears again after a while, check the log writings from the concerned ICSU (IPA-RNC Control plane unit) for example by using MML command ZDDE:ICSU,:"ZGDIC;"; The ICSU unit index to be used is shown in the 3rd supplementary information field of this alarm. To collect the necessary data for troubleshooting, initiate message monitorings in the concerned ICSU unit (IPA-RNC Control plane unit) mentioned in 2nd and 3rd supplementary information fields of this alarm (families 04FE, 04FB) and in active OMU unit. In Multi-Controller RNC and Flexi Direct RNC the detailed family logs can be collected from location in the product "/srv/Log/log/".
258
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7772 HSDPA CONFIGURATION FAILED
Start the Physical Shared Channel Reconfiguration procedure by locking and unlocking the cell and wait for the alarm to be set again. Collect the logs and monitorings and contact the local Nokia Siemens Networks representative. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected. Locking or deleting of the cell, or next succeeded configuration of HSDPA channels cancels the alarm.
DN99580892
Id:0900d805809d5c0d Confidential
259
7773 INSECURE O&M CONNECTION
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
43 7773 INSECURE O&M CONNECTION Meaning The alarm indicates that one or more network elements have established an O&M connection with insecure protocol while the controller is configured in probing security mode. In probing mode the secure connections are preferred, i.e. the alarm may be an indication of a failure in setting up a secure connection. Problems in transport layer or incorrect certificates installation would cause the network element to establish the connection with controller with insecure protocol when the controller is configured in probing mode. Supplementary information fields 1
this represents the actual reason for Controller accepting insecure connection. The field value may indicate: - problems in transport layer Error code: 11728 = TRANSPORT PROTOCOL ERROR 11730 = TRANSPORT SERVICE MISBEHAVIOUR 16654 = TRANSPORT LAYER CAUSE UNSPECIFIED - incorrect certificates installation in the network element Error code: 16212 = NO CERTIFICATES FOUND 16213 = FOUND MULTIPLE CERTIFICATES 17485 = CERTIFICATE IS EXPIRED Instructions
To analyze and correct the problem, check the 1st supplementary information field value. The 1st supplementary information field indicates the reason why the network element is not able to establish the secure connection with the controller when it is in probing mode. To correct the problem, ensure that the correct certificates are installed in the controller as well as in the network element which is trying to establish the secure O&M connection. After the right certificates are installed at the Controller end, operator should trigger the TLSmode as probing which will make Controller to close the server port and open the port with right certificates. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
260
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7775 INCONSISTENCY IN WCEL CONFIGURATION PARAMETERS
44 7775 INCONSISTENCY IN WCEL CONFIGURATION PARAMETERS Meaning The alarm indicates inconsistency in parameterization between controller and BTS. It may be raised because of these reasons: 1. Nokia Siemens Networks specific configuration parameters in BTS might not be consistent with the parameters in controller. These parameters are CellRange, RACHCapacity, SIB7factor, ShutdownWindow, and ShutdownStepAmount. The situation causing this alarm does not obstruct network operations. 2. The WCEL in the object unit of the alarm has too many adjacencies configured so that the size of the System Information Block (SIB) would exceed the maximum size. In case of parameter inconsistency, the alarm is set when BTS has failed to accept the parameters sent to it during cell setup or when BTS has not responded to the parameter sending during cell setup. The alarm is cancelled automatically after these configuration parameters have been successfully sent to BTS. In case of SIB data encoding failure, the controller has dropped some of the configured adjacencies automatically to enable the SIB sending for the cell and allowing it to be activated. The alarm is cancelled automatically after the adjacency configuration has been modified so that SIB sending can be done normally for the cell. A certain WCEL may have multiple instances of this alarm raised for each different reason simultaneously. The alarm is cell-specific and its indication to NetAct has been prevented by default in IPA-RNC. The controller-specific alarm 3325, INCONSISTENCY IN CONFIGURATION PARAMETERS, is related to this alarm and one instance of it is activated when this alarm has been raised to one or more cells in a certain controller. This controller-specific alarm is sent to NetAct by default. Alarm indication preventions can be altered with MML command AFC in IPA-RNC. Supplementary information fields 1
name of the reason why the failure was observed. Possible values: * *
2
SIB_FAIL = SIB sending failure INCONSIS = BTS parameters are not consistent with the controller
general error message of the system. You can check its meaning
DN99580892
Id:0900d805809d5c0d Confidential
261
7775 INCONSISTENCY IN WCEL CONFIGURATION PARAMETERS
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
with a command of the service terminal extension MRS or in the General Error Messages of System Instructions Case 1: If the alarm reason given in the first supplementary information field is INCONSIS: Check the cell parameters CellRange, RACHCapacity, SIB7factor, ShutdownWindow and ShutdownStepAmount in controller using Element Manager. If these parameter values are the same as those in the BTS Site Configuration File, no actions are needed in controller. Check if other alarms are active for the BTS or WCEL in question. If the cell parameters in controller are not the same as those in the BTS Site Configuration File and these parameters need to be updated, the following actions can be taken to the cell that has failed to accept the parameters sent: * Modify these parameters with Element Manager. This is recommended if the cell works, that is, cell state (WCEL state) is WO. * Lock the cell and then unlock it with Element Manager. This operation causes the parameters to be resent to the BTS. More information about the exact failure reason can be found by examining the error code given in 2nd supplementary information field. Probable error code values are: * 94 = NO RESPONSE BTS has not responded to parameter sending in time or response did not include all the cells the parameters where sent to. * 15472 = WBTS HARDWARE OVERLOAD BTS is temporarily too busy to handle new requests. * 15477 = EQUIPMENT FAILURE A HW failure has occurred. * 15480 = NO RESOURCES IN WBTS Node B resources are unavailable. * 16504 = INTERNAL NBAP ERROR PREVENTING PROCEDURE COMPLETION An internal error that prevents parameter sending has occurred. In these fault cases the actions mentioned above should repair the situation. Fault cases with error code EQUIPMENT FAILURE may also require repairing of BTS HW. Case 2: If the alarm reason given in the first supplementary information field is SIB_FAIL:
262
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7775 INCONSISTENCY IN WCEL CONFIGURATION PARAMETERS
Check the number of neighboring cells (ADJS, ADJI and ADJG) configured for the WCEL in question in controller. Reduce the number of neighboring cells either by modifying or deleting ADJS, ADJI and/or ADJG objects of this cell. In many cases there is more information in the OMU computer log. In IPA-RNC it can be studied with the MML-command ZDDE::"ZGSC"; Detailed information can be collected from location "/srv/Log/log/" in the Multi-controller RNC/I-HSPA ADA. This contains the detailed logs for all the families. Cancelling Do not cancel the alarm. The system cancels the alarm automatically after these parameters/SIBs have been sent successfully to the WBTS.
DN99580892
Id:0900d805809d5c0d Confidential
263
7776 HSDPA FAILURE IN WCEL
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
45 7776 HSDPA FAILURE IN WCEL Meaning A major fault (or faults) occurs in the BTS. A unit (or units) that take care of HSDPA traffic in WCEL can be faulty, or there is not enough capacity available in the BTS WSP cards for the HSDPA service. This alarm is set when an HSDPA-capable BTS sends a Resource Status Indication (RSI) message via NBAP to RNC indicating that HSDPA state is changed to "disabled". As a consequence of this alarm, HSDPA connections cannot be used in that particular cell. The RSI message regarding HSDPA disabling can arrive also after the whole cell is reported as "disabled" by BTS via another RSI message. This can happen in BTS recommissioning phase when the cell is disabled in the BTS end as part of the BTS maintenance operations. In this case this alarm can appear together with the alarms for the same WCEL object: 7761 RNW O&M SCENARIO FAILURE 7771 WCDMA CELL OUT OF USE In case the overall WCEL object state is WO (working) when this alarm appears, check the reason for the fault from the BTS WSP-related alarms. Supplementary information fields
Instructions First check the WCEL operational state using RNW RNC Object Browser. If the WCEL operational state is not WO (working), ignore this alarm and analyze the problem with the WCEL taking into account the other active alarms for the same WCEL or its parent WBTS object. If the WCEL operational state is WO, check in the RNC the WSP-related active alarms that are targeted to the related WBTS object. The alarms to be checked are: 7650 BASE STATION FAULTY 7651 BASE STATION OPERATION DEGRADED 7652 BASE STATION NOTIFICATION The faulty unit is mentioned in supplementary information field 3 of these alarms. Check all WSP-related alarms because any of the WSP-related fault can be the reason for this alarm. If a HSDPA-dedicated WSPC unit in BTS is faulty, the BTS reserves another WSPC when it becomes free from other traffic. For more information on BTS alarms, see WCDMA BTS Alarm
264
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7776 HSDPA FAILURE IN WCEL
Descriptions (SW and release documentation). Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault is corrected.
DN99580892
Id:0900d805809d5c0d Confidential
265
7778 WCDMA BTS DEDICATED MEASUREMENT FAILURE
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
46 7778 WCDMA BTS DEDICATED MEASUREMENT FAILURE Meaning This alarm is set when Dedicated Measurement (for transmitted code power) Initiation fails due to the following three cases during cell initialization: 1) BTS problem, such as no response or nack 2) NBAP-D link is down 3) NBAP-D module has a problem (controller internal) Controller retries Dedicated Measurement Initiation after the corresponding NBAP-D link is re-created to be ready. If the retry succeeds, the alarm is cancelled. After this alarm, cells' capacity under the BTS might be affected. Supplementary information fields 1
general error code of the system. You can check its meaning with a command of the service terminal extension MRS (see Service Terminal Essentials, Maintenance Manual) or from the document General Error Messages of System, Supplementary References
2
communication control port id Instructions
First, check if there are other alarms active for the BTS in question and follow the instructions given for those alarms. This alarm is cancelled if the problem is solved by correcting the other active alarms. If there are no obvious faults indicated by active alarms and this alarm is not cancelled by system, follow the instructions given in the steps below according to error code given in the first supplementary information field. 1. Error code 13247 no_answer_from_remote_end_ec 15479 nbap_bts_hw_res_not_avail_ec
No response from BTS BTS hardware failure
These codes indicate that response from BTS was not received for Dedicated Measurement Indication or BTS hardware failure. The operation can be retried by creating the corresponding NBAP-D again using Element Manager (this operation causes all the cells of the BTS being unavailable for traffic): 1) Lock all the cells under the BTS. 2) Remove the WBTS id from the COCO(IPA-RNC)/IPNB.
266
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7778 WCDMA BTS DEDICATED MEASUREMENT FAILURE
3) Add the WBTS id to the COCO(IPA-RNC)/IPNB again. 4) Unlock these cells. If creating the NBAP-D again does not help, the problem may reside on the BTS end. It should be analyzed by connecting to corresponding BTS using BTS Manager. 2. Error code 13288 dst_link_failure_ec 13846 no_resp_from_serv_provider_ec
NBAP-D link has been down NBAP-D process no response
The operation in step 1 can be attempted, it may help if the problem was only temporary. If the operation in step 1 does not help, the communication problem between controller processes should be analyzed by taking message monitoring from controller OMU when the unlocking of the cells is done. See the last part of this instruction for information about collecting the needed monitorings and logs. 3. Any other error code: Try to perform NBAP-D link creation again using instructions given in step 1.
If this doesn't help, a BTS restart may be attempted to solve the situation. If the problem persists after these steps, contact the local Nokia Siemens Networks representative. Attach OMU message monitorings for troubleshooting: IPA-RNC: For process 3C6, all of ICSUs message monitoring for process 4FE, OMU computer log and error log (MML-commands ZDDE::"ZGSC"; and ZDDE::"ZGLE";), and alarm history (MML-command ZAHP or using Fault Management application in controller EM). Multi-Controller RNC or Flexi Direct RNC: Message monitoring for families can be collected from location "/srv/Log/log/" in the product. Also alarm history can be collected by using SCLI command "fsclish -c "show alarm history"" or using Fault Management application in controller EM. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
DN99580892
Id:0900d805809d5c0d Confidential
267
7779 RECOVERY ACTIONS ONGOING
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
47 7779 RECOVERY ACTIONS ONGOING Meaning The alarm indicates that controller has started WBTS recovery actions due to a non-performing WCDMA cell. During recovery actions it cannot transmit any traffic. The alarm is set when some of the following situations occur: 1. Common measurements are missing and common measurement recovery actions have failed. 2. Common measurement initialization constantly fails. 3. Common channel creation constantly fails. 4. There is poor handover-related radio link setup ratio. 5. There is poor FACH RRC connection setup/complete ratio. 6. Base Station resource manager process family (BRM) hand crashes in controller. 7. There is constant radio link failure acknowledged by NodeB during RRC connection setup. This alarm informs operator that recovery actions are ongoing. The recovery actions include WBTS reset that takes a while. During this recovery action no other user actions are recommended. The alarm is cancelled automatically after the WBTS recovery actions have been completed. After this operator can start to perform user actions again. After this alarm has been cancelled and BTS recovery actions have ended, it is possible that other recovery actions are started if cells are still in some block state. Alarm 7761 or 7762 is set if a failure occurred during WBTS initialization after the WBTS reset. Supplementary information fields 1
this value indicates the cause that has led to recovery actions: 00 01 02 04 05 06 08
268
Common measurements are missing and common measurement recovery actions have failed. Common measurement initialization constantly fails. Common channel creation constantly fails. Poor handover related radio link setup ratio. Poor FACH RRC connection setup/complete ratio. Constant radio link failure acknowledged by NodeB. Base Station resource manager process family (BRM) hand crash in controller.
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7779 RECOVERY ACTIONS ONGOING
Instructions This alarm does not require any actions. WBTS recovery actions are started when other recovery actions have not recovered the cell. The reason for WBTS recovery actions is indicated in the 1st supplementary information field. If cell still does not work after the WBTS recovery actions have ended and no reason behind it can be found, collect at least the following logs and contact the local Nokia Siemens Networks representative: IPA-RNC: - OMU computer log (MML-commands ZDDE::"ZGSC"; and ZDDE::"ZGLE";) - alarm history (MML-command ZAHP or using Fault Management application in controller EM) - message monitoring from OMU (families 50B, 4FA) and serving ICSU (check serving ICSU from COCO(IPA-RNC) data in Element Manager, monitor families 4FE, 4FB, 4FD, 4B7) during WBTS reset Multi-Controller RNC or Flexi Direct RNC: Message monitoring for all families can be collected from location "/srv/Log/log/" in the product. Also alarm history can be collected by using SCLI command "fsclish -c "show alarm history"" or using Fault Management application in controller EM Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
DN99580892
Id:0900d805809d5c0d Confidential
269
7780 HSUPA FAILURE IN WCEL
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
48 7780 HSUPA FAILURE IN WCEL Meaning A major fault (or faults) occurs in the BTS. A unit (or units) taking care of HSUPA traffic in the WCEL can be faulty, or there is not enough capacity available on the BTS WSP cards for HSUPA service. This alarm is set when an HSUPA-capable BTS sends a Resource Status Indication (RSI) message via NBAP to the RNC indicating that HSUPA state is changed to "disabled". As a consequence of this alarm, HSUPA connections cannot be used in that particular cell. The RSI message regarding HSUPA disabling can arrive also after the whole cell is reported as "disabled" by BTS via another RSI message. This can happen in BTS recommissioning phase when the cell is disabled in the BTS end as part of the BTS maintenance operations. In this case this alarm can appear together with the alarms for the same WCEL object: 7761 RNW O&M SCENARIO FAILURE 7771 WCDMA CELL OUT OF USE In case the overall WCEL object state is WO (working) when this alarm appears, check the reason for the fault from the BTS WSP-related alarms. Supplementary information fields
Instructions First check the WCEL operational state using RNW RNC Object Browser. If the WCEL operational state is not WO (working), ignore this alarm and analyze the problem with the WCEL taking into account the other active alarms for the same WCEL or its parent WBTS object. If the WCEL operational state is WO, check in the RNC the WSP-related active alarms that are targeted to the related WBTS object. The alarms to be checked are: 7650 BASE STATION FAULTY 7651 BASE STATION OPERATION DEGRADED 7652 BASE STATION NOTIFICATION The faulty unit is mentioned in supplementary information field 3 of these alarms. Check all WSP-related alarms because any of the WSP-related faults can be the reason for this alarm. If a HSUPA-dedicated WSPC unit in the BTS is faulty, the BTS reserves another WSPC when it becomes free from other traffic. For more information on BTS alarms, see WCDMA BTS Alarm
270
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7780 HSUPA FAILURE IN WCEL
Descriptions (SW and release documentation). Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault is corrected.
DN99580892
Id:0900d805809d5c0d Confidential
271
7781 NETWORK ELEMENT CONFIGURATION ERROR
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
49 7781 NETWORK ELEMENT CONFIGURATION ERROR Meaning The alarm indicates that the NEType indicated by the BTS and the Iub Working Mode configured in the controller for the WBTS object do not match. The controller sets this alarm when such a mismatch is detected after the BTS O&M link establishment. The -
consequences of this alarm are: WCEL unlocking operation under this BTS is denied. WCEL creation under this BTS is denied. WCEL modification under this BTS is denied. The creation, modification, and connection of a related COCO (IPA-RNC)/IPNB are denied. - WBTS modification is denied. - WBTS and its child objects can be deleted. - WCEL can be locked.
The alarm is canceled automatically when the WBTS is deleted, or no mismatch is detected after the BTS O&M link establishment. Supplementary information fields 1
indicates the BTS model in the WCDMA. The meanings of the possible values and the corresponding GUI abbreviations are: 00 - Not used 01 - Other 02 - UltraSite BTS 03 - FlexiBTS 04 - PicoBTS 05 - Wimax 09 - NB/RSxxx 17 ? FlexiLiteBTS
2
indicates the used communication mode for NodeB via the NBAP interface. The meanings of the possible values and the corresponding GUI abbreviations are: 00 - UltraSite BTS, FlexiBTS, PicoBTS 01 - NB/RSxxx Instructions
The WBTS deletion and recreation are required when correcting the incorrect configuration. The WBTS recreation is needed because the Iub Working Mode is a non-modifiable parameter that must be given in the WBTS object creation phase. Step 1:
272
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7781 NETWORK ELEMENT CONFIGURATION ERROR
Check, using the Topology Browser, if there are WCELs under this WBTS. If so, lock all these WCEL objects and delete them. Step 2: Delete the WBTS object. Step 3: Recreate the WBTS object with the correct Iub Working Mode parameter value. Next, recreate the WCEL objects under this WBTS. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the WBTS is deleted, or no mismatch is detected after the BTS O&M link establishment.
DN99580892
Id:0900d805809d5c0d Confidential
273
7782 HSUPA CONFIGURATION FAILED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
50 7782 HSUPA CONFIGURATION FAILED Meaning This alarm indicates that there has been an error when controller requested configuration or reconfiguration of HSUPA channels to BTS via Physical Shared Channel Reconfiguration (PSCR) procedure. The possible causes which result in this alarm are: - There has been a problem in transmission network between controller and BTS. - BTS has rejected the configuration or reconfiguration of HSUPA channels. - Controller is unable to send the HSUPA configuration to BTS because of controller internal problems (for example congestion in Iub interface) Location and the nature of the failure can be determined from the supplementary information fields of this alarm. The consequence of this alarm depends on the HSUPA configuration phase where the failure occurred. - If the failure occurred in the initial HSUPA configuration or in delivering the HSUPA parameters to the BTS, the HSUPA connections cannot be used in this particular cell at all. - If the failure occurred in the reconfiguration of the HSUPA, the effect is that the cell may not work with the intended HSUPA parameters. Supplementary information fields 1
reason of the alarm Possible 01 = 02 = 03 =
values: No reply from BTS BTS rejects the configuration Controller internal error
2
computer unit where this alarm is generated from
3
index of the alarming unit
4
this info field is applicable if the 1st supplementary information field value is 01
5
more detailed cause in case the BTS rejects the configuration Possible values: 00 = Error in radio network configuration 01 = Error in transport layer
274
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7782 HSUPA CONFIGURATION FAILED
02 = Error in NBAP protocol layer 03 = Miscellaneous The value in this field is applicable if the 8th supplementary information field value is 02 or 03 6
possible values sent by the BTS, value meaning depends on the cause that is given in the 4th supplementary information field: 00 01 06 09
= = = =
Unknown cell ID (RNW configuration) Cell not available (RNW configuration) Node B resources unavailable (RNW configuration) Requested configuration not supported (RNW configuration) 03 = Message Not Compatible With Receiver State (protocol)
00 = Control processing overload (Misc) 03 = Not enough user plane processing resources (Misc) 04 = Unspecified (Misc) The value in this field is applicable if the 8th supplementary information field value is 02 or 03 7
more detailed cause in case the value of the 1st supplementary information field is 03 ("Controller Internal error"). Possible values: 306 328 402 404 420 501 504 505 506 507 508 510 529
= = = = = = = = = = = = =
Internal waiting timer expired in BTS Resource Manager BTS overloaded Wrong BTS ID Wrong cell ID No free DL Spreading Codes available for HSUPA Internal waiting timer expired in NBAP interface Encoding failed in NBAP interface Decoding failed in NBAP interface Parallel procedure not allowed Unit switchover State conflict Table full NBAP link down
The value in this field is applicable if the 8th supplementary information field value is 02 or 03 8
phase of HSUPA configuration 01 = Delivering HSUPA parameters to BTS 02 = Initial HSUPA configuration 03 = Reconfiguration of HSUPA
DN99580892
Id:0900d805809d5c0d Confidential
275
7782 HSUPA CONFIGURATION FAILED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
04 = PWSM HSPA05 reconfiguration failure Instructions Step 1: Check first the nature of the problem. The 8th supplementary information field value indicates the phase in which the problem has occurred: 01: Delivering HSUPA parameters to BTS 02: Initial HSUPA configuration The problem has occurred during initial HSUPA setup to a cell. The effect of this is that HSUPA cannot be used in the cell. Proceed to the step 2 in this instruction. 03: Reconfiguration of HSUPA The problem has occurred during HSUPA reconfiguration to a cell. The effect is that the HSUPA may not work with the intended parameters. In this case it is recommended that HSUPA is disabled and enabled in the cell to confirm that proper parameters are taken into use. This action requires cell locking. 04: PWSM HSPA05 reconfiguration failure The problem has occurred during HSUPA reconfiguration to a cell when Power Saving Mode For BTS (PWSM) feature was performing HSPA05 reconfiguration. HSPA05 reconfiguration has been stopped and no cell deletion or activation by PWSM feature is done. In this case it is recommended to disable PWSM feature. Do cell lock/unlock to recover cell HSUPA parameters and state. If cell is not recovered using lock/unlock operation, a BTS restart can be attempted using Element Manager or BTS Site Manager. Step 2: The first supplementary information field indicates the main reason for the problem. 01: No reply from WBTS Problem may reside somewhere in transmission network to BTS. Check if there are other active alarms for the WBTS object and follow the instructions given for those alarms. If there are no apparent problems shown via other alarms, check the type of network problem with the following instructions: Precondition for Physical Shared Channel Reconfiguration
276
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7782 HSUPA CONFIGURATION FAILED
procedure is that the C-NBAP link to WBTS is active. Check the state of C-NBAP link of this WBTS object from Element Manager main dialog. If the C-NBAP link works, the problem may reside in the BTS. Check the BTS configuration and logs using BTS Manager. If the C-NBAP link does not work, check the success of PING between controller and BTS. Successful PING tells that the BTS is up and running: MML command: ZQRX (IPA-RNC) Normal Ping command : Multi-controller RNC/Flexi Direct RNC If ping does not succeed, then the problem is in lower level of the transmission network. Check physical connections in network. If ping succeeds, then the problem is in application level. In many cases there is also more information in OMU computer log. IPA-RNC : Logs can be studied with MML-command ZDDE::"ZGSC"; Multi-Controller RNC or Flexi Direct RNC: Logs can be collected and studied from location "/srv/Log/log/" in the product. 02: BTS rejects the configuration Check that the concerned BTS is in working state using controller Element Manager. If the working state of the BTS is OK, check that the BTS has correct HW configuration so that HSUPA can be supported (WSPC cards) using BTS Manager. If the working state of the BTS and the BTS HW configuration are OK, but this fault still occurs, contact the local Nokia Siemens Networks representative. In case the fault is related to RNW configuration (based on the 4th and the 5th alarm supplementary information fields of this alarm), check the configuration of this WBTS object in controller using Element Manager, and the configuration in BTS using BTS Manager. Check also if other alarms are active targeted to this same WBTS object. If there are active alarms, proceed according to instructions given for those alarms. If the fault cannot be resolved by correcting the configuration or other BTS alarms, contact the local Nokia Siemens Networks representative. 03: Controller internal error An internal error in controller has occurred during Physical
DN99580892
Id:0900d805809d5c0d Confidential
277
7782 HSUPA CONFIGURATION FAILED
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
Shared Channel Configuration procedure. If the 6th supplementary information field of this alarm has a value 306, 420, 501, 504, 505, 506, 508, 510 or 529, the situation may be resolved by locking and unlocking the cell. This operation cancels the alarm and triggers the Physical Shared Channel Reconfiguration procedure again. If the problem was only temporary, the alarm should not appear again. If the alarm appears again after a while, check the log writings from the concerned ICSU, for example by using MML command ZDDE:ICSU,:"ZGDIC;"; The ICSU unit index to be used is shown in the 3rd supplementary information field of this alarm. To collect the necessary data for troubleshooting, initiate message monitorings in the concerned ICSU (IPA-RNC Control plane unit) mentioned in the 2nd and the 3rd supplementary information fields of this alarm (families 04FE, 04FB) and in active OMU unit. In Multi-Controller RNC and Flexi Direct RNC the detailed family logs can be collected from location in the product "/srv/Log/log/". Start the Physical Shared Channel Reconfiguration procedure by locking and unlocking the cell and wait for the alarm to be set again. Collect the logs and monitorings and contact the local Nokia Siemens Networks representative. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected. Locking or deleting of the cell, or next succeeded configuration of HSDPA channels cancels the alarm.
278
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7783 IP BASED D-NBAP LINK FAILURE
51 7783 IP BASED D-NBAP LINK FAILURE Meaning One or more IP-based D-NBAP links of a WCDMA BTS are detected lost by the controller. The user plane traffic handling capability of the WCDMA BTS is degraded, or the traffic capability of the whole WCDMA BTS is totally lost. This alarm is set only if the fault is detected in IP-based D-NBAP link(s) of the WCDMA BTS. The alarm is not set for IP-based D-NBAP links if the C-NBAP link is unavailable at the same time. Supplementary information fields 1
IPv4 address of the remote end. This field is filled with zeroes if IPv6 addressing is in use.
2
IPv6 address of the remote end. This field is filled with zeroes if IPv4 addressing is in use. Instructions
See the NBAP link operational states for the WCDMA BTS from Topology Browser in controller OMS to see which of the configured D-NBAP links are unavailable. In case this alarm is set right after the WBTS is enabled in the system, verify using Topology Browser that the IPNB object configuration in controller is correct in relation to the network setup. Otherwise, the problem is likely to be located either in the BTS or in IP transmission between the BTS and the controller. See other possible active BTS-originated alarms (7650, 7651) that can indicate the reason for the failure. Use BTS Site Manager to see the operation status in the BTS end for additional troubleshooting. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
DN99580892
Id:0900d805809d5c0d Confidential
279
7784 RECOVERY ACTION FAILURE
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
52 7784 RECOVERY ACTION FAILURE Meaning This alarm indicates that automatic WCDMA BTS recovery action performed by controller has failed. The recovery has been attempted because some of the WCELs under the WBTS have been detected not to be performing properly. The observed cause for the recovery is given in alarm supplementary information. For more information about the recovery functionality behind this alarm, see feature descriptions for features RAN1302 and RAN1810 in Product Documentation. The reason for the recovery failure is one of the following: - The amount of WBTS recovery actions (restarts) have been used up for a specific WBTS object for the current day. - BTS restart failed due to missing BTS O&M connection. - BTS does not respond to restart request. - BTS is busy handling software upgrade and rejects the restart request. As a result of this alarm the traffic handling capacity of the WCDMA BTS may be reduced because some WCELs do not perform properly. Recovery action is resumed by controller again after the fault preventing the recovery action has been corrected and if the problem affecting the WCEL performance still remains. Supplementary information fields 1
this value indicates the type of failure that prevented the recovery action. Possible values are: 00 01 02 03 04 05 06 07
2
this value indicates the cause that has led to recovery actions: 00 01 02 04 05 06
280
Amount of BTS restarts as recovery action has been used up. BTS restart failed due to missing BTS O&M connection. BTS restart failed due to no response from BTS. BTS restart rejected by BTS due to ongoing BTS SW upgrade. BTS restart failed because of invalid BTS O&M message. BTS restart failed due to non-supported field value in BTS O&M message. BTS restart failed due to unknown object type in BTS O&M message. BTS restart failed due to controller internal errors.
Common measurements are missing and common measurement recovery actions have failed. Common measurement initialization constantly fails. Common channel creation constantly fails. Poor handover related radio link setup ratio. Poor FACH RRC connection setup/complete ratio. Constant radio link failure acknowledged by NodeB.
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
08
7784 RECOVERY ACTION FAILURE
Base Station resource manager process family (BRM) hand crash in controller.
3
this value indicates the Local WCEL resource id for the WCEL that was detected not to be performing properly. In case the problem is not related to any specific WCEL (if the 2nd supplementary information field value is 08) then this value is set to FFFFFFFF (4294967295d).
4
this value indicates the allowed amount of WBTS recovery actions (restarts) per day. It is defined in PRFILE parameter RN22_FEATURE_OPT_009 (002:1296). Instructions
Check the reason for the recovery failure from the 1st supplementary information field and proceed accordingly. 00: The amount of performed BTS restarts as recovery action per day exceeds the limit which is given in the 4th alarm supplementary information field. In this case the BTS cannot be restarted by controller until next midnight when controller resets the BTS specific restart amount counters. The BTS can be recovered manually by restarting it using either Element Manager or BTS Site Manager. Increasing the allowed BTS restart amount in PRFILE enables controller to perform additional restarts for BTS sites that have no recovery attempts left. 01: BTS O&M connection between BTS and controller is not available and restart could not be performed. See if controller alarm 7750 is active for possible details on the fault concerning the BTS O&M connection. Check also the status of BTS O&M connection from BTS Site Manager. See instructions below for possible need to perform manual recovery actions depending on the 2nd supplementary information field value. 02: BTS does not respond to the reset request. This may be due to high load in BTS side. Check the BTS status using BTS Site Manager and restart the BTS manually if possible. See instructions below for possible need to perform manual recovery actions depending on the 2nd supplementary information field value. 03: BTS software upgrade is ongoing and BTS cannot be restarted at the moment. BTS restarts after the software upgrade has been completed. 04, 05, 06: Unexpected error has occurred in BTS O&M message handling. The reason might be that controller and BTS do not use compatible version of the BTS O&M interface. Collect OMU computer log from controller and also logs from the BTS in question. Fill in a problem report and send it to the local Nokia Siemens Networks representative.
DN99580892
Id:0900d805809d5c0d Confidential
281
7784 RECOVERY ACTION FAILURE
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
See instructions below for possible need to perform manual recovery actions depending on the 2nd supplementary information field value. 07: controller internal errors might be that reading BTS related information from database failed or there are already some other recovery actions going on for the BTS. See if alarms 7761 or 7762 have been set for the WBTS in question. See instructions below for possible need to perform manual recovery actions depending on the 2nd supplementary information field value. Check also the value of the 2nd supplementary information field and, if it's value is 08 (BRM hand crash), proceed accordingly based on the 1st supplementary information field value. 01, 02, 04, 05, 06, 07: In these recovery failure cases the BTS must be restarted manually using the BTS Site Manager or, if that is not possible for some reason, COCO/IPNB object disconnect and connect operation from the WBTS object in controller using Element Manager must be performed. Both of these operations trigger C-NBAP link re-establishment and cause a complete reinitialization of the cells. These user actions are required to ensure that cells are properly recovered after BRM hand crash.
Controller OMU computer log can also provide further information about the attempted recovery actions. IPA-RNC : "ZGSC:,50B" and "ZGSC:,4FA" Multi-Controller RNC or Flexi Direct RNC: Use command "grep -i rekove /var/log/syslog", Use command "grep -i rezini /var/log/syslog" It is recommended that controller OMU logs (ZGSC and ZGLE for IPA-RNC) are collected together with BTS logs for possible further troubleshooting when this alarm is observed. Detailed logs can be collected from location "/srv/Log/log/" in the Multi-Controller RNC/Flexi Direct RNC. This contains the detailed logs for all the families. Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
282
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7786 WCDMA BASE STATION OUT OF USE
53 7786 WCDMA BASE STATION OUT OF USE Meaning This alarm indicates that there is a WBTS-level failure that causes all the WCELs in the WO state under this specific WBTS to become unavailable. This alarm is set when a known fault occurs and makes all the WCELs under a certain WBTS to become unavailable at once. The reasons for this are the C-NBAP link break or Base Station Resource Manager (BRM) hand crash in the controller. As a result of this alarm, the whole WBTS is unavailable for traffic. There can be also individual WCEL level alarms active for the WCELs of this WBTS if they were active prior to the WBTS level failure detection. This alarm is set only if there is at least one cell in the WO state under the WBTS. This alarm is canceled when at least one WCEL under the WBTS is recovered back to the WO state, or if the user locks all the WCELs under the WBTS. For more information on this functionality, see Nokia Siemens Networks WCDMA RAN documentation concerning feature RAN1461. Supplementary information fields 1
reason why all the WCELs became unavailable at once. The possible reasons are: 00 = C-NBAP link break 01 = BRM hand crash 02 = Link switch failure during rebalancing operation Instructions
The 1st supplementary information field indicates the reason why the whole WBTS became unavailable. The field contains the first observed reason for the problem. This means that during recovery actions the whole WBTS can become unavailable, but the reason can change. For example, it is possible that the BRM hand crash causes the original problem, but after its recovery the C-NBAP link can be unavailable. The original alarm is kept active, as from the system point of view the whole WBTS is still unavailable. To analyze and correct the problem, check the 1st supplementary information field value. 00: C-NBAP link break
DN99580892
Id:0900d805809d5c0d Confidential
283
7786 WCDMA BASE STATION OUT OF USE
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
This can be caused by different underlying reasons that are indicated as the C-NBAP link break to RNW O&M: - a transmission break between controller and BTS resulting from, for example, a cable or external transmission equipment failure, a BTS restart performed using BTS Site Manager, or a controller network interface unit failure. - an internal controller failure, for example a spontaneous ICSU (IPA-RNC)/ Control plane unit (Multi-controller RNC/Flexi Direct RNC) restart. In case of the C-NBAP link failure the recommendation is to wait for a couple of minutes and check if the disturbance is only temporary. The system recovers automatically once the transmission between the controller and BTS is available again. In case of a longer WBTS unavailability, it can be checked if the controller has active alarms for (IPA-RNC)/ Control plane unit (Multi-controller RNC/Flexi Direct RNC) or network interface units that can cause the C-NBAP link unavailability. The relation between WBTS and (IPA-RNC)/ Control plane unit (Multi-controller RNC/Flexi Direct RNC) unit can be seen from WBTS data using the Element Manager (the controller GUI for BTS Connection Resources dialog). 01: BRM hand crash The system recovers from the situation automatically. This reason may trigger non-performing cell recovery actions in controller, meaning that the BTS gets restarted by the controller. 02: Link switch failure during rebalancing operation This value is valid only in Multi-controller RNC and it indicates that the link switch for this BTS from donating CSCP to receiving CSCP has failed. This situation cannot be recovered automatically. WBTS-IPNB needs to be disconnected and then connected again to recover this WBTS. As for the behavior of this alarm when the WBTS level failure indication in feature RAN1461 state is changed, note the following: 1. When the WBTS level fault functionality is switched from OFF to ON state, there are no effects on the existing WCEL alarms under a certain WBTS. The effect can be seen on the following alarms set by the system. 2. When the WBTS level fault functionality is switched from ON to OFF state, and if this alarm is active for a WBTS, the functionality for this particular WBTS is still considered as working. This means that the WBTS level failure alarm is kept active as long as all the WCELs for that WBTS remain unavailable.
284
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7786 WCDMA BASE STATION OUT OF USE
Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.
DN99580892
Id:0900d805809d5c0d Confidential
285
7794 ALARM STATUS REQUEST HAS TIMED OUT
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
54 7794 ALARM STATUS REQUEST HAS TIMED OUT Meaning The alarm indicates that due to the lack of the upload acknowledgement message from the BTS, the alarm upload cannot be started between the BTS and the controller. The alarm is set when two consecutive alarm upload requests have been sent by the controller without an acknowledgement from the BTS. If this alarm occurs, there can be a difference in alarm conditions between the controller and the BTS. The precondition to set this alarm is that the BTS O&M link is active. If the BTS O&M link is not active at the moment of the alarm upload attempt, alarm 7750 is set instead. Supplementary information fields
Instructions No actions are needed in the controller. Use the BTS Site Manager to see the operation status in the BTS end for an additional troubleshooting. Cancelling Do not cancel the alarm. The system cancels the alarm after the BTS has acknowledged the alarm upload status request and when the upload can be started.
286
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7795 INCONSISTENCY IN HIGH PEAK RATE HSPA CONFIG
55 7795 INCONSISTENCY IN HIGH PEAK RATE HSPA CONFIG Meaning The alarm indicates that the High Peak Rate HSPA configuration parameters (for DC HSDPA or Dual Band HSDPA or HSUPA IC) in at least one WCEL of the BTS might not be consistent with the parameters in the RNC. In DC HSDPA case this alarm is also raised if the BTS loses its capability of supporting DC HSDPA. This is also a result if user locks one of the cells in the cell pair during maintenance activities. The situation causing this alarm does not obstruct network operations. The alarm is cell-specific, and not indicated to NetAct by default. Instead, the RNC-specific alarm 3325, "INCONSISTENCY IN CONFIGURATION PARAMETERS", is reported on NetAct when first instance of 7795 is set. The alarm 7795 is cancelled by the system when configuration at BTS and RNC is consistent for High Rate HSPA features (DC HSDPA, Dual Band HSDPA and HSUPA IC) or when the cell is deleted/locked. Alarm indication preventions can be altered with MML command AFC in IPA-RNC. Supplementary information fields 1
2
possible error code values are: *
746d
= DC HSDPA NOT AVAILABLE local Cell in the BTS is not Multi Cell Capable, whereas the Controller has the DC HSDPA feature enabled in the cell
*
1352d = ADMINPICSTATE SET BY OPERATOR IS MISMATCHING WITH PIC STATE RECEIVED FROM NODE-B PICState at BTS and AdminPICState set by Controller are inconsistent
*
2139d = Local Cell is not Dual Band Capable local Cell in the BTS is not Dual Band Capable whereas the Controller has the Dual band HSDPA feature enabled in the cell
name of the feature for which the setup failed. Possible values: * *
DCHSDPA HSUPAIC
DN99580892
= Dual Cell HSDPA = HSUPA Interference Cancellation
Id:0900d805809d5c0d Confidential
287
7795 INCONSISTENCY IN HIGH PEAK RATE HSPA CONFIG
*
DBHSDPA
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
= Dual Band HSDPA Instructions
The situation causing this alarm does not obstruct network operations, and therefore no immediate actions are required. However, you can take the following actions to ensure consistency in configuration parameters. In case of DC HSDPA related problem, check first that the cell pair of the cell indicated in this alarm is not locked by user before proceeding to the steps given below. If that is the case, then the eventual unlocking of the DC HSDPA cell pair will clear this alarm. 1. Find the cells that might have inconsistency in configuration parameters by checking the alarms in the RNC. For these cells, proceed to step 2. 2. a) If the 2nd supplementary information field value is "DCHSDPA": Check the cell parameter WCEL - DCellHSDPAEnabled in the RNC using the OMS EM. BTS may reject the Dual Cell HSDPA configuration if the HW mapped for the Cell is not supporting HSPA, or if the frequency configuration is not properly done, so: - Check from BTS side that the HW mapped to the Cell resource is capable of providing HSPA. - Check from RNC side that the WCEL UARFCN configuration is done according to instructions given in RAN1906 feature activation manual. - If configuration parameters have inconsistency then lock the cell, correct WCEL UARFCN configuration as well as other parameterization as mentioned in RAN1906 feature activation manual. - Unlock the cell if were locked in previous step. b) If the 2nd supplementary information field value is "HSUPAIC": Check the cell parameter WCEL - AdminPICState in the RNC using the OMS EM. If AdminPICState is "enabled" then this alarm indicates that BTS failed to configure HSUPA IC. If AdminPICState is "disabled" then it indicates that BTS has not disabled HSUPA IC even though configuration at RNC is changed to disable HSUPA IC. In such cases, proceed to step-3. c) If the 2nd supplementary information field value is "DBHSDPA": Check the cell parameter WCEL- DBandHSDPAEnabled in the Controller using the OMS EM. BTS may reject the Dual Band HSDPA configuration if the HW mapped for the Cell is not supporting HSPA, or if the frequency configuration is not properly done, so: - Check from BTS side that the HW mapped to the Cell resource is
288
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
7795 INCONSISTENCY IN HIGH PEAK RATE HSPA CONFIG
capable of providing HSPA. - Check from RNC side that the WCEL UARFCN configuration is done according to instructions given in RAN1906 feature activation manual. - If configuration parameters have inconsistency then lock the cell, correct WCEL UARFCN configuration as well as other parameterization as mentioned in RAN1906 feature activation manual. - Unlock the cell if were locked in previous step. 3. Check if there are any BTS end failures that are indicated with 76xx alarms and that could affect this feature (e.g. some HW unit failure) Check if the relevant BTS is in the working state using the OMS EM. If the working state of the BTS and the BTS HW configuration are correct while this fault still occurs, contact the local Nokia Siemens Networks representative. More information about the exact failure reason can be found by examining the 1st supplementary information field (error code). You can check its meaning in IPA-RNC with a command of the service terminal extension MRS (see Service Terminal Essentials, Maintenance Manual), in multi-controller RNC / Flexi Direct RNC using CLI command "dxserrcli " or from the document General Error Messages of System, Supplementary References. For more information about configuring DC HSDPA and DB HSDPA features, see the respective feature activation manuals in product documentation. Cancelling Do not cancel the alarm. The system cancels the alarm after the BTS has indicated to the RNC that it supports the high peak rate HSPA feature in the cell in case of DC HSDPA or Dual band HSDPA or BTS and RNC has consistent PIC States in case of HSUPA IC. The alarm will also be cancelled when the cell is deleted or locked.
DN99580892
Id:0900d805809d5c0d Confidential
289
7796 HIGH SPEED COMMON CHANNEL PROBLEM
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
56 7796 HIGH SPEED COMMON CHANNEL PROBLEM Meaning This alarm indicates a failure in HS FACH or HS RACH common channels in the cell. It is set for the cell when - the creation of HS FACH/HS RACH common channel fails - the capability of the WCEL mismatches with HS FACH/HS RACH capability on BTS side - HS FACH/HS RACH common channels are unavailable due to sync loss between BTS and RNC. If this alarm is raised, then UE DRX feature becomes out of use (if it was already enabled) as both features (HS FACH and HS RACH) are pre-requisite for operation of UE DRX feature. Supplementary information fields 1
error code, possible values are: - 1315d = High speed cell FACH is enabled in the controller but Disabled or not supported in the BTS. - 1316d = Synchronization between the BTS and controller is lost for HS FACH channels and those are unavailable. - 1914d = High Speed Cell FACH UL is enabled in the controller but disabled or not supported in the BTS. - Besides these above specific error code, there can be other error code corresponding to failures identified during High Speed FACH/ HS RACH channel creation. For instance, insufficient DSP resources. Instructions
Case 1) The first supplementary information field value is 1315d (enh_fach_capb_mismatch_ec). Possible reasons: - There is a mismatch of the HS-DSCH channel configuration between the controller and BTS. - BTS HW does not support HS FACH common channels - BTS runs out of capability due to, for example, a HW failure. Actions to be taken: 1)
290
Check if there are any BTS end failures that are indicated with 76xx alarms and that could affect this feature (for example some HW unit failure).
Id:0900d805809d5c0d Confidential
DN99580892
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
2)
7796 HIGH SPEED COMMON CHANNEL PROBLEM
Check if the relevant BTS is in the working state using the controller Element Manager. If so, check whether the BTS HW configuration is correct so that Enhanced HSFACH can be supported. If the working state of the BTS and the BTS HW configuration are correct while this fault still occurs, contact the local Nokia Siemens Networks representative.
Case 2) When the first supplementary information field value is 1316d (hs_cch_sync_ec): Possible Reason: Synchronization between the controller and BTS is lost for the HS FACH common channel. Actions to be taken: The continuous recovery is performed by the controller. An attempt can be made to solve the problem by locking and unlocking the cell manually. Case 3) The first supplementary information field value is 1914d (enh_rach_capb_mismatch_ec). Possible reasons: - There is a mismatch of the E-DCH channel configuration between the controller and BTS. - BTS HW does not support HS RACH common channels - BTS runs out of capability due to, for example, a HW failure. Actions to be taken: 1) If the fault is related to the RNW configuration, check the E-DCH configuration of this WBTS object in the controller using the Element Manager, and the configuration in the BTS using the BTS Manager. 2) Check if the relevant BTS is in the working state using the controller Element Manager. If so, check whether the BTS HW configuration is correct so that Enhanced HS RACH can be
supported.
If the working state of the BTS and the BTS HW configuration
DN99580892
Id:0900d805809d5c0d Confidential
291
7796 HIGH SPEED COMMON CHANNEL PROBLEM
Multicontroller RNC, IPA-RNC and Flexi Direct RNC Base Station Alarms (7000-7900)
are correct while this fault still occurs, contact the local Nokia Siemens Networks representative.
If the fault cannot be fixed by correcting the configuration, checking other BTS alarms, or continuous recovery attempts on the cell, contact the local Nokia Siemens Networks representative. For information on the exact reason of the failure, see the 1st supplementary information field. You can check its meaning with a command of the service terminal extension MRS (see Service Terminal Essentials, Maintenance Manual) or in the document General Error Messages of System, Supplementary References. For more information, you can also examine the OMU computer log accessed with the MML command ZDDE::"ZGSC" in IPA-RNC and in Multi-Controller RNC/Flexi Direct RNC logs can be found at location in the product "/srv/Log/log/". Cancelling Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected. The alarm is cancelled when either of the following occurs: - The creation of HS FACH/HS RACH common channel in the cell is successful. - The cell is deleted from the Node-B. - The cell is deleted internally from the controller as a result of the audit procedure. Any earlier instance of this alarm in a WCEL is cancelled when the alarm is set with cause 1315d (enh_fach_capb_mismatch_ec). Any earlier instance of this alarm raised to indicate the transport channel failure with cause 1316d (hs_cch_sync_ec) is cancelled when the request for setting the alarm is received with any another cause for the same cell.
292
Id:0900d805809d5c0d Confidential
DN99580892