INSTRUCTION 1 (11) Prepared (also subject responsible if other) No. Lai Le Approved Date 2014-07-25
Rev
Reference
Checked
A MOP SIU REPLACEMENT FOR VNP2
Section
Page
1 LAPTOP SETUP: ...................... ........................... ..... .............................................. ...................... .................................. .......... 2 2 BACKUP SIU CONFIGURATION FILE (XML) TO LA PTOP. .................. 3 3 SITE SPECIFIC STEP-BY-STEP .............. ............................................. ...................... ....................... 4 4 SWAP SIU HARDWARE ...................... ........................ .............................................. ...................... .......................... 10
This MOP describes the procedure to replace all SIUs with productRevision productRevision =R1G on live network VNP2. The procedure is used the step by step for backup a configuration on one S IU and then restore this configuration on another SIU which will replace in. For here, ASP/SUB wil l be easy implement SIU replacement, and also less impact to customer services.
Important notes for ASP/SUB : Be sure to have the correct SIU Software (T12B_ CXP 102 138/1 R2AB).
This software will be getting from E///. Laptop must be working well. Ethernet cable. Software supports SSH/Telnet (Puty or Secure CRT). Software supports SFTP server (should be used Core FTP mini). Site specific configuration (xml file) backup file included in this p rocedure. Make sure replaced new SIU is different version R1G. Once you have had the correct SIU software and backup file, extract those t o a folder off your PC in ªC:\ SIUº. If you haven't already created a SIU folder off your C:\ drive.
----------------------- Page 2-----------------------
INSTRUCTION 2 (11) Prepared (also subject responsible if other) No. Lai Le Approved Date
Rev
2014-07-25 1
Reference
Checked
A LAPTOP SETUP: SETUP Description
NOTE: If you have any problems with any steps of this MOP, DO NOT PROCEED , Contact your PM immediately. The Steps below need to be executed in the specified sequence on all impa cted nodes. SET COMPUTER IP TO: 192.168.1.2 255.255.255.0 192.168.1.1 Setup a telnet session for connecting to SIU local console port:
SIU IP address: 192.168.1.1 login: admin password: hidden LAUNCH FTP PROGRAM (User: siu ; Pass: siu) & Port: 22 1. Double click on the file msftpsrvr.e xe to start the mini-sftp server program on your PC. 2. Change these values on the mini-sftp -server as below 3. The password is
4. Then click on start button to start the SFTP server
----------------------- Page 3-----------------------
UCTION
3 (11)
Prepared (also subject responsible if other)
INSTR No.
Lai Le Approved
Rev
07-25
Checked
Reference
2014-
A
2
Date
BACKUP SIU CONFIGURATION FILE (XML) TO LAPTOP. (Activities on existing SIU) Step
Description
Backup SIU xml file to Laptop 1
Login to SIU will be replaced: ssh [email protected] Pass: hidden
tắc SIU_HCxxxx_old.logº
ªSetting lấy logfile thứ 1, file lưu theo quy
xxxx: là số cụ thể của trạm đó. 2
Check Product Revision and Serial code OSmon> getmoattribute STN=0,Equipment=0 STN=0,Equipment=0; instanceId= 0; STN=0,Equipment=0; serialNumber= CB4H230708; STN=0,Equipment=0; productRevision= R1G; (or: R1G/A; R1E
/C)
STN=0,Equipment=0; productNumber= KDU 137 596/2; STN=0,Equipment=0; manufacturingDate= 20110404; OperationSucceeded laced by another one. 3
4
Note: Product Revisions are R1G; R1G/A; R1E/C must be rep Check alarm SIU OSmon> getalarmlist OperationSucceeded Note: Please capture/get alarm screen on existing SIU. OSmon> getmoattribute stn=0 OSmon> getmoattribute
----------------------- Page 4-----------------------
INSTRUCTION
4 (11)
Prepared (also subject responsible if other) No. Lai Le Approved Date
Rev
2014-07-25
A 5
Reference
Checked
OSmon> getmoattribute STN=0,TGTransport=all Here's 2G ID. STN=0,TGTransport=HC1047_TG900; instanceId= HC1047_TG90
0;
STN=0,TGTransport=HC1047_TG900; operationalState= enabl
ed;
STN=0,TGTransport=HC1047_TG900; PGW_IP_Address= 10.213.
240.195;
STN=0,TGTransport=HC1047_TG900; depIP_Interface= STN=0,
IPInterface=2G;
STN=0,TGTransport=HC1047_TG900; STN_PGW_LinkStatus= up; STN=0,TGTransport=HC1047_TG900; overloadThreshold= 1000
;
STN=0,TGTransport=HC1047_TG900; overloadReportInterval=
1;
STN=0,TGTransport=HC1047_TG900; DSCP_L2TP_CP= 40; OperationSucceeded
r not, and know what's 4
====> From here, we can know this SIU has used for 2G o 2G ID. Backup the SIU xml configuration to Laptop OSmon> uselocalsftp on OperationSucceeded OSmon> startSession bcm1 OperationSucceeded
Cxxx.xml admin
OSmon> backup bcm1 sftp://siu:[email protected]/SIU/SIU_H OperationSucceeded OSmon> getsessionstatus bcm1 UploadCompleted OperationSucceeded OSmon> endSession bcm1 A backup xml file will appear at path on laptop: C/SIU/
new SIU. 3
This backup xml file will used to restore for replaced SITE SPECIFIC STEP-BY-STEP (Activities on new SIU)
Power cables are connected temporary to new SIU from PWR out 2 port of RBS 6601. -
Check the power LED indicator is lit.
Connect an Ethernet cable from the laptop p ort to the `Console' port on the SIU. 1.
----------------------- Page 5-----------------------
INSTRUCTION 5 (11) Prepared (also subject responsible if other) No. Lai Le Approved
Date
Rev
2014-07-25
(Sub netmask 255.255.255.0). 2.
Checked Reference
A The SIU local maintenance IP address is 192.168.1.1 login: admin Password: hidden Reset SIU to factory setting. (Chỉ thực hiện trên con SIU
mới) 3. e (ok/cancel)? OK.
OSmon> resetToFactorySetting Warning: All user settings will be removed, continu OperationSucceeded Re-Login SIU:
4. quy tắc SIU_HCxxxx_before_upgrade.logº
ªSetting lấy logfile thứ 2, file lưu theo
Check current HW revision
=========> Revision OK. 5.
OSmon> getmoattribute STN=0,Equipment=0 STN=0,Equipment=0; instanceId= 0; STN=0,Equipment=0; serialNumber= CB4B682659; STN=0,Equipment=0; productRevision= R1E/ D; ====== STN=0,Equipment=0; productNumber= KDU 137 596/2; STN=0,Equipment=0; manufacturingDate= 20100111;
with R1G; R1G/A; R1E/C.
OperationSucceeded The new SIU has ªproductRevisionº must be different
----------------------- Page 6-----------------------
INSTRUCTION
6 (11)
Prepared (also subject responsible if other) No. Lai Le Approved Checked Reference
Date
Rev
2014-07-25
A
t SIU software level as follows)
--------------------------tenance
Port
or ircuit Emulation Service Emulation
Check current SIU Software
(Check the curren
OSmon> rev ------------------- OSE modules --------------oam.chk secmgrr.chk inetr.chk ltp.chk snc.chk pd.chk cesopsn_pwr.chk hdlc_pwr.chk p_relayr.chk profiler.chk
R1F03
Operation & Main R2J01 Security Manager R2G02 MLPPP Daemon R2D03 Local Terminal R2D03 Synchronization R2H02 Packet Distribut R1L_1 C HDLC Pseudo-Wire R1H07 Packet Relay R2H01 System Profiler
hwtest.chk lcf_cp.chk
ty Function
bsp.drv
ckage
bootstrap.chk loader.drv 6.
linuxload.drv
---------------------------
---------------------------
Linux Loader R2H02
------------------- Firmware modules ---------PBOOT
CXC 112 3777/1 R1G02 ------------------- Software archives --------Primary: OSE Linux Backup: OSE
---------------------------
R1L_1 Hardware Tester P2A01 Local Connectivi R1C01 Board Support Pa R2H02 Bootstrap R2G02 Software Loader R1L_1
CXP102128_1 R2J01 R2J01
CXP102084_1 R3F01 ------------------- Active software ----------OSE Linux
Primary Primary
In this case: CXP102128_1 (R2J01) is version T 11B, old version. So, We must be upgraded to correct SW T12B: CXP 102 138/1 R2AB as step 7.
----------------------- Page 7-----------------------
INSTRUCTION 7 (11)
Prepared (also subject responsible if other) No. Lai Le Approved d
Date
Rev
2014-07-25
A
Checke Reference
Upgrade SIU Software step by step: The software upgrade requires a SFTP server runni ng on your PC. The software and configuration files will be downloaded from your PC to the SIU. Start the SFTP server on your PC and configure it with the username and password `siu' and set Root path to c: Enter the following commands: OSmon> uselocalsftp on OSmon> startswsession 1 OperationSucceeded U/T12B_siu02_sw.tar 7.
complete.
OSmon> downloadsw 1 sftp://siu:[email protected]/SI OperationSucceeded OSmon> getswsessionstatus 1 DownloadInProgress OperationSucceeded Wait up to 5 minutes for the software download to OSmon> getswsessionstatus 1 DownloadCompleted OperationSucceeded
When the software download is completed, activate the software using the following command: OSmon> activatesw 1 OperationSucceeded .
The SIU will restart and connectivity will be lost
----------------------- Page 8-----------------------
INSTRUCTION
8 (11)
Prepared (also subject responsible if other) No. Lai Le Approved Checked Reference
Date
Rev
2014-07-25
A
Re-Login to the SIU: ªSetting lấy logfile thứ 3, file lưu theo q uy tắc SIU_HCxxxx_after_upgrade.logº OSmon> getswsessionstatus 1 ActivationCompleted SIU Software upgrade was successful
====>
OperationSucceeded OSmon> endswsession 1 OperationSucceeded Check the software revision and verify that the primary software is the latest version and the SIU is running on the primary application as follows:
--------------------------tenance
Port
or
OSmon> rev ------------------- OSE modules --------------oam.chk secmgrr.chk inetr.chk ltp.chk snc.chk pd.chk
Operation & Main R2J01 Security Manager R2G02 MLPPP Daemon R2D03 Local Terminal R2D03 Synchronization R2H02 Packet Distribut R1L_1
8.
Emulation
cesopsn_pwr.chk hdlc_pwr.chk p_relayr.chk profiler.chk hwtest.chk
ty Function ckage
lcf_cp.chk bsp.drv bootstrap.chk loader.drv linuxload.drv
---------------------------
---------------------------
Circuit Emulation Service R1F03 HDLC Pseudo-Wire R1H07 Packet Relay R2H01 System Profiler R1L_1 Hardware Tester P2A01 Local Connectivi R1C01 Board Support Pa R2H02 Bootstrap R2G02 Software Loader R1L_1 Linux Loader R2H02
------------------- Firmware modules ---------PBOOT
CXC 112 3777/1 R1G02 ------------------- Software archives --------Primary: OSE Linux Backup: OSE
---------------------------
R2AB05
CXP102084_1 R3F01 ------------------- Active software ----------OSE Linux
2B.
-
CXP102138_1 R2AB05
Primary Primary
Make sure the primary is activated software T1
----------------------- Page 9-----------------------
INSTRUCTION 9 (11)
Prepared (also subject responsible if other) No. Lai Le Approved ecked rence
Date
Rev
2014-07-25
A
p of item 2 above)
Ch Refe
Restore SIU configuration xml file. (Configuration xml file has just gotten from ste
Make sure your SFTP server is running. The SIU c onfiguration file must be in XML format. OSmon> uselocalsftp on OSmon> startsession bcm1 OperationSucceeded
SIU/SIU_HCxxx.xml 9.
OSmon> download bcm1 sftp://siu:[email protected]/ OperationSucceeded
OSmon> getsessionstatus bcm1 DownloadCompleted OperationSucceeded When the file download is complete, activate the configuration using the following command: Osmon> restore bcm1 admin OperationSucceeded The SIU will restart and connectivity will be lo
st
Re-Login to the SIU and enter the following comm
ands: uy tắc SIU_HCxxxx_ready.logº
10.
ªSetting lấy logfile thứ 4, file lưu theo q OSmon> getsessionstatus bcm1 ActivationCompleted OperationSucceeded OSmon> endsession bcm1
OperationSucceeded
Note: If any errors are encountered while loadin g the script, contact Ericsson support. OSmon> getalarmlist OSmon> getmoattribute stn=0 OSmon> getmoattribute stn=0,equipment=0
11.
OSmon> getmoattribute
----------------------- Page 10-----------------------
INSTRUCTION 10 (11) Prepared (also subject responsible if other) No. Lai Le Approved
Date
Rev
2014-07-25
A
Checked Reference
Check SIU LED indicators are normal tors in the SIU.
Refer to figure in step 1 to locate the LED indica Indicator Status Fault Power
12.
Off On
Opera.
On
Sync
On
Info.
Off
If the Fault or Info. LED is lit, troubleshoot and
clear the fault.
Make sure, all ports and parameters on new SIU are defined correct as existing SIU. 4
SWAP SIU HARDWARE
- Make sure, new SIU finished restoration configu ration & working status is ready. 1.
- Must be making labels on all cables connected to ports of existing SIU. ===> very very important.
- After, anything is ready. ASP will call for E/// guys confirm starting time swap SIU. When accepted by E///. ASP will turn off power existing SIU & replace ne w SIU. as before swap.
- Make sure, all cable are reconnected correction 2.
- Check physical links are up. - And then, ASP need contact with E/// guys as soo
n as possible.
----------------------- Page 11-----------------------
INSTRUCTION 11 (11) Prepared (also subject responsible if other) No. Lai Le Approved ked e
Date
Rev
Chec Referenc
2014-07-25
A
Log-in to new SIU after replaced and enter the f
ollowing commands:
ªSetting lấy logfile thứ 5, file lưu theo qu
y tắc SIU_HCxxxx_new.logº
Check alarms in the SIU 3.
OSmon> getalarmlist Troubleshoot and clear any alarms. Note:
- Make sure after swap, all alarms are the same as before swap on the both SIU/Node B/RBS 2G. Ping to OSS OSmon> ping 10.149.27.67 PING (10.26.2.65) 56(84) bytes of data. 64 bytes from 10.26.2.65: icmp_seq=0 ttl=255 time
=1.824 ms
64 bytes from 10.26.2.65: icmp_seq=1 ttl=255 time
=1.702 ms
64 bytes from 10.26.2.65: icmp_seq=2 ttl=255 time
=1.681 ms
4.
=1.706 ms
64 bytes from 10.26.2.65: icmp_seq=3 ttl=255 time 64 bytes from 10.26.2.65: icmp_seq=4 ttl=255 time
=1.715 ms
--- 10.26.2.65 ping statistics --5 packets transmitted, 5 received, 0.0% packet lo
ss
round-trip min/avg/max = 1.000/1.725/1.823 ms ===> To stop ping result, use CRT+C If the ping is not successful, then troubleshoot
.
Note: Make sure ping to OSS ok. Enter the following commands to print the SIU co
nfiguration:
OSmon> getmoattribute stn=0 5.
OSmon> getmoattribute stn=0,equipment=0 OSmon> getmoattribute OSmon> log read
All 5 logfiles will keep on your laptop and send to Ericsson for audit (or V NP requirement later on). 6 te.
Waiting confirm from OMC/Eric before leave the si