Cluster ** Optimization Report Date(20110418) Author(**)
www.huawei.com
Contents Cluster ** Optimization Report..........................................................................................................1 1 Basic Information........................................................................................................................3 1.1 Drive Test Route.........................................................................................................3 1.2 Details of Network Optimization Activities...............................................................3 1.3 New sites recomandation............................................................................................4 2 Statistics Information..................................................................................................................5 2.1 CS Event Summary.....................................................................................................5 2.2 Handover Summary....................................................................................................5 3 IE Statistics..................................................................................................................................6 3.1 RxLev Sub...................................................................................................................6 3.2 RxQual Sub.................................................................................................................7 3.3 BER Sub......................................................................................................................9 3.4 BCCH along with BSIC Plot....................................................................................10 3.5 FER Sub....................................................................................................................11 3.6 C/I Worst...................................................................................................................12 3.7 Power Control Level.................................................................................................14 3.8 TA..............................................................................................................................15 4 Event Troubleshooting..............................................................................................................17 4.1 Event Map.................................................................................................................17 4.2 Event Summary.........................................................................................................17 4.3 KPI Report................................................................................................................18 4.4 Event and Case Analysis...........................................................................................18 4.4.1 Handover Failure..............................................................................................18 4.4.2 Call Drop...........................................................................................................19 4.4.2.1 Call Drop 1 :.............................................................................................19 4.4.2.2 Call Drop 2 :.............................................................................................21 4.4.1 Weak coverage..................................................................................................22 4.4.1.1 Weak coverage 1.......................................................................................22
www.huawei.com
1 Basic Information
1.1 Drive Test Route
1.2 Details of Network Optimization Activities •
• •
•
Physical Verification of Sites for any discrepancies in implementation versus planning data. Please Site Audit Template Parameter consistency checks and gets the change request implemented. Parameter dump can be provided as on when required. Detailed drive tests with Long call and short call to verify the call performance in terms of receive level, call quality, call set up, handovers, call drops. Done. Coverage optimization by means of physical changes at site. Refer Site Audit Template
www.huawei.com
• •
Signal level checked at various major hotspots. Please refer the drive plots. Sector swap details if any. Refer Site Audit Template
Audit data cluster 8.xlsx
1.3 New sites recomandation Show it in Mapinfo and give planed site list as exel.
www.huawei.com
2 Statistics Information
2.1 CS Event Summary Name Call Attempt Counter
Value 56
Call Setup Failure Counter
0
Call Setup Counter
50
Call Drop Counter
0
HO Request Counter
311
HO Success Counter
301
SDCCH Call Setup Assigned Success Counter
48
SDCCH Call Drop Counter
0
Call Setup Success Rate(Total)
90.91%
Call Drop Rate(Total)
0.00%
InterCell HO Success Rate
96.78%
SDCCH Call Drop Rate
0.00%
Location Update Counter
8
Location Update Failure Counter
0
Location Update Failure Rate
0.00%
RAU Attempt Counter
12
Distance Sum For RxLev All >= -90 dBm
92659.87m
Kilometer per Drop Call
N/A
Cell Reselection Average Interval
1339.97s
Call Setup Delay Average
2.78s
2.2 Handover Summary Name HO Request Counter
Value 311
HO Success Counter
301
HO Failure Counter
10
InterCell HO Success Rate
96.78%
HO Failure Rate
3.22% www.huawei.com
IntraCell HO Failure Counter
0
IntraCell HO Success Counter
2
3 IE Statistics
3.1 RxLev Sub
www.huawei.com
Maximum
Minimum
Average -70.15dBm
Standard Deviation 10.28
71
Cumulation(%) 0.22
Density(%) 0.22
943
3.09
2.87
[-90,-80)
4197
15.86
12.78
[-80,-70)
10381
47.46
31.60
[-70,-10]
17259
100.00
52.54
-47.00dBm
-107.00dBm
Range [-120,-100)
Count
[-100,-90)
www.huawei.com
3.2 RxQual Sub
www.huawei.com
Range 0
Count 22113
Cumulation(%) 67.31
Density(%) 67.31
1
1936
73.21
5.89
2
992
76.23
3.02
3
1539
80.91
4.68
4
1597
85.77
4.86
5
1414
90.08
4.30
6
1612
94.98
4.91
7
1648
100.00
5.02
3.3 BER Sub
www.huawei.com
Maximum 70.70% Range
0.00% Count 13723
1.66% Cumulation(%) 96.13
Standard Deviation 4.57 Density(%) 96.13
Range [0,2)
Count 27434
Cumulation(%) 83.77
Density(%) 83.77
[2,4)
1512
88.39
4.62
[4,8)
1409
92.69
4.30
[8,100]
2393
100.00
7.31
[0,2)
Minimum
Average
www.huawei.com
3.4 FER Sub
www.huawei.com
Maximum
0.00%
2.63%
Standard Deviation 15.99
[0,2)
Count 31291
Cumulation(%) 97.37
Density(%) 97.37
[2,4)
0
97.37
0.00
[4,8)
0
97.37
0.00
844
100.00
2.63
100.00% Range
[8,100]
Minimum
Average
www.huawei.com
3.5 C/I Worst
Maximum
Minimum
Average
www.huawei.com
Standard
17.28dB
Deviation 3.08
3
Cumulation(%) 0.01
Density(%) 0.01
[0,5)
88
0.29
0.28
[5,9)
802
2.87
2.58
1589
7.97
5.11
[12,20)
24835
87.77
79.79
[20,35]
3808
100.00
12.23
23.28dB Range [-30,0)
-5.89dB Count
[9,12)
3.6 Power Control Level
www.huawei.com
Maximum
0.00
6.02
Standard Deviation 7.90
Count 11802
Cumulation(%) 37.22
Density(%) 37.22
13793
80.72
43.50
[10,15)
6112
100.00
19.28
[15,20)
0
100.00
0.00
[20,25)
0
100.00
0.00
[25,31]
0
100.00
0.00
255.00 Range [0,5) [5,10)
Minimum
Average
www.huawei.com
3.7 TA
www.huawei.com
Maximum
0.00dBm
0.14dBm
Standard Deviation 0.49
[0,1)
Count 28420
Cumulation(%) 89.68
Density(%) 89.68
[1,2)
2727
98.29
8.61
[2,3)
208
98.94
0.66
[3,4)
193
99.55
0.61
[4,5)
72
99.78
0.23
[5,10)
70
100.00
0.22
[10,32)
0
100.00
0.00
[32,63]
0
100.00
0.00
5.00dBm Range
Minimum
Average
www.huawei.com
4 Event Troubleshooting
4.1 Event Map
4.2 Event Summary Name SDCCH Call Drop Counter
Value 0
Call Drop Counter
0
Location Update Failure Counter
0
HO Failure Counter
10
www.huawei.com
www.huawei.com