Home
Add Document
Sign In
Register
HVAC Cooling Load Estimate Sheet
Home
HVAC Cooling Load Estimate Sheet
Simple & Easy way to calculate HVAC Cooling/Heating load...
Author:
jijk5
11 downloads
221 Views
52KB Size
Report
DOWNLOAD .PDF
Recommend Documents
HVAC Cooling Load Procedure Guideline Lo0
Full description
HVAC Cooling Load Procedure Guideline Lo0
Descripción completa
HVAC Load Calculations Guide
HVAC load calculation guide for designers.Full description
Cooling Load Calculation
HVAC Load Calculations Guide
HVAC load calculation guide for designers.Descripción completa
HVAC load calculation
HVAC load calculationFull description
1-HVAC Load Explorer V1
LOAD
Excel Sheet Load List
electricalFull description
08_ Cooling Load Rules of Thumb 61294_06
Descrição completa
08_ Cooling Load Rules of Thumb 61294_06
ASHRAE cooling load calculations and principles.pdf
CHAPTER 10 Cooling Load January 2012
Hvac Load Calculations of a Villa
Senior Project
Estimate
Microscope Glossary
Estimate
estimate
HVAC
Hvac
CALCULATION HVAC
HVAC
HVACFull description
HVAC
Full description
HVAC
HVAC
HVACDescription complète
Labor Estimate
Labor estimate factor
Formula Estimate
estimates
Estimate r
Full description
Project No.
Room No :
Name : Room Size.
Sq. Ft. x
Cu. Ft.
Estimated by :
Date :
Checked by : COOLING LOAD Condition Outside Inside Difference
OUTSIDE AIR :
D.B 115 75 40
W.B 82
% R.H
Gr/lb. 112 72 40
50%
0
PERSON X 10 = 0
Area or
Sun gain or
quantity
Temp. Diff.
Date : HEATING LOAD Condition Inside Outside Difference
D.B
0
0 Sq. Ft.
15.3
0.56
Glass S
0 Sq. Ft.
13.06
Glass W
0 Sq. Ft.
178.8
Glass E
0 Sq. Ft.
13.08
0.56
Wall N
0 Sq. Ft.
37
0.1
Wall S
0 Sq. Ft.
45
0.1
Wall W
0 Sq. Ft.
43
0.1
Wall E
0 Sq. Ft.
52
0.1
Roof
0 Sq. Ft.
63
0.1
Sky light
0 Sq. Ft.
235
0.52
Windows
Sq. Ft.
30 x 1.13
0.56
0
Walls
Sq. Ft.
30 x
0.56
0 0 0 0 0 0 0 0
Partition
Sq. Ft.
25 x
Ceiling
Sq. Ft.
25 x
Floor
Sq. Ft.
25 x
Infilt
Sq. Ft.
30 x 1.1
SUB TOTAL SAFETY FACTOR 10%
ROOM HEAT LOSS
0 Sq. Ft.
40
1.13
Infiltration
Sq. Ft.
40
1.08
Sh. Wall
Sq. Ft.
Partition
0 Sq. Ft.
32
.38
Gl. Part.
0 Sq. Ft.
People
Sq. Ft.
20
.38
0 Sq. Ft.
10
.38
0 0 0 0 0 0 0
INTERNAL HEAT 0 Person 215 150
Appliances
Sq. Ft.
Lights
1.13 Watt x 3.412
0 Watts/m2
BTU / HR.
HEAT LOSS
0
TRANSMISSION GAIN (Except walls & roof)
Floor
Gr/lb.
AIR CHANGES / HR……………….CFM.
BTU / HR
Glass N
Ceilling
% R.H
Factor
SUNLIGHT GAIN
All Glass
W.B
3.41
1.25
O : A Loss
CFM x
x 1.1
TOTAL HEAT LOSS REMARKS TOTAL HEAT
0 Btu/hr
act. Ton
0
0 0 0
Room Sensible Heat Subtotal
0
SAFETY FACTOR "A" 10%
0
ROOM SENSIBLE HEAT
0
N. B. : SAFETY FACTOR "A"
ROOM LATENT HEAT People
0 Person
*
235
Steam
0 x lb/Hr.
*
1000
0 0 0 0 0
Room Latent Heat Subtotal
SAFETY FACTOR "B" 7 % ROOM LATENT HEAT ROOM TOTAL HEAT OUTSIDE AIR HEAT 0 CFM 40° F x 1.08 0 CFM x 40 Gr/lb x 0.67
=
5%
GRAND TOTAL HEAT Assume Rm
2%
Fan H.P.
3%
Safety Factor.
5%
Supply Duct Leakage Loss.
2%
Safety Factor.
5%
SAFETY FACTOR "C"
Latent
TONS
5%
Supply Duct Leakage Loss.
SAFETY FACTOR "B"
0
Sens.
SAFETY FACTOR "C"
Reheat Supply Duct. Ht. Gain.
0 0
Return Duct Heat Gain.
2%
Return duct Leakage Gain.
3%
0
Pump H. P.
2%
0
Dehum. & Piping Los.
3%
T ( Temp. Diff. Between Rm. Design Temp. and air off Coil D. B. Temp ) = …………F S.A.C.F.M =
Rm.S.Hi 1.08 x
T
0 1.08 * 18
0 cfm
18° F
×
Report "HVAC Cooling Load Estimate Sheet"
Your name
Email
Reason
-Select Reason-
Pornographic
Defamatory
Illegal/Unlawful
Spam
Other Terms Of Service Violation
File a copyright complaint
Description
×
Sign In
Email
Password
Remember me
Forgot password?
Sign In
Our partners will collect data and use cookies for ad personalization and measurement.
Learn how we and our ad partner Google, collect and use data
.
Agree & close