Home
Add Document
Sign In
Register
load flow problem
Home
load flow problem
load flow problemDescripción completa...
Author:
chintanp
7 downloads
113 Views
26KB Size
Report
DOWNLOAD .PDF
Recommend Documents
Load flow PPT
Descripción: Load flow PPT
05 - Unbalanced Load Flow
Unbalanced Load FlowFull description
Ieee p3002.2 Load Flow
Load Flow StudiesFull description
Load Flow Studies
Descripción: load flow studies
Vertical Channel Flow Problem
Problem to be solved using ANSYS Fluent
ETAP IPP Load Flow Example
Solar Power Load FlowFull description
Load Flow Basic Principles Digsilent
03 IRENA Load Flow Analysis
Full description
Load Flow Basic Principles Digsilent
Descripción completa
03 - Load Flow and Panel
Full description
CPT3 - Load Flow Analysis-6th Batch
Full description
Ybus formation for load flow studies
gaurav ranjanFull description
Review of Load Flow Calculation Methods
Descripción: Review of load flow calculation methods
CPT3 - Load Flow Analysis-6th Batch
Full description
Modeling of Sources in Load Flow
Modeling of Sources in Load FlowFull description
ANALISA LOAD FLOW Laporan Pasca Pelatihan
load flowDeskripsi lengkap
LOAD FLOW ACTIVITY DESCRIPTIONS PSS RAW
LOAD FLOW ACTIVITY DESCRIPTIONS READ Siemens Power Transmission & Distribution, Inc. Power Technologies InternationalFull description
Problem Analysis Flow Charts for GSM KPIs
Problem Analysis Flow Charts for GSM KPIs.doc
KPI Analysis
Flow
Full description
Problem
Problem
Ieee 14 Bus System Load Flow Using n
NEWTON RAPHSON LOAD FLOW USING IEEE 14 BUS SYSTEM TO FIND OUT BUS VOLTAGES AND LINE LOSSESDescripción completa
Simulasi Load Flow Analysis ETAP 12 Power Station.pdf
Simulasi Load flow analisa etapFull description
Experiment2: Load Flow analysis of 4 bus system using Powerworld Simulator. Line Data Line
-
Z series
Y series=Z
Bus to Bus
R(pu)
X(pu)
G(pu)
B(pu)
1-2 1-3 2-4 3-4
0.01008 0.00744 0.00744 0.01272
0.05040 0.03720 0.03720 0.06360
3.815629 5.169561 5.169561 3.023705
-19.078144 -25.847809 -25.847809 -15.118528
Pload (MW) 50 170 200 80
Qload (Mvar) 30.99 105.35 123.94 49.58
Y Shunt Total charging Mvar 10.25 7.75 7.75 12.75
Y/2 per unit 0.05125 0.03875 0.03875 0.06375
Bus Data Bus
Pgen (MW) Qgen(Mvar)
1 2 0 3 0 4 318 Base MVA=100 MVA Base KV=230 KV
0 0 -
V, pu
Remarks
1.0 1.0 1.0 1.0
slack Load bus Load bus PV bus
×
Report "load flow problem"
Your name
Email
Reason
-Select Reason-
Pornographic
Defamatory
Illegal/Unlawful
Spam
Other Terms Of Service Violation
File a copyright complaint
Description
×
Sign In
Email
Password
Remember me
Forgot password?
Sign In
Our partners will collect data and use cookies for ad personalization and measurement.
Learn how we and our ad partner Google, collect and use data
.
Agree & close