Huawei Tools Description
VHA AUS 9th Mar 2012
Confidential 1 © Nokia Siemens Networks
M2000
Confidential 2 © Nokia Siemens Networks
M2000 The main tasks that can be performed on M2000 are: To fetch the Dump To activate Measurement counters Modify the parameters To define Custom KPI’s. To define KPI report template To fetch KPI reports To fetch Alarms(both History and Active) Note: In M2000, KPI reports can be fetched only either by Cell level or by RNC level. Hence PRS tool is preferred to fetch the KPI report which is more user friendly and also similar to the NGR of NSN.
Confidential 3 © Nokia Siemens Networks
M2000: To fetch the Dump
Confidential 4 © Nokia Siemens Networks
M2000: To fetch the Dump 1. 2. 3. 4.
Open the MML command window Select the NE type Select the RNC of which the dump is required Type the command “Exp CFGMML” and execute it.(Path and filename is not mandatory) 5. Open the WebLMT of the respective RNC to download the configuration file. a) To open the WebLMT, Go into the Main topology, Right click on the RNC and select the Maintenance Client. b) In the main window of Weblmt, Click on the File manager and browse the file path to download it. Note: The file downloaded will be in .txt format. Respective snaps are attached in the next slides.
Confidential 5 © Nokia Siemens Networks
M2000: To fetch the Dump// running MML Command
Select the type of NE (RNC or BSC)
Type the Command and execute
Confidential 6 © Nokia Siemens Networks
To retrieve the saved file, please refer the next slide.
The file will be saved in the mentioned path.
M2000: To fetch the Dump// WebLMT
Select the File manager
Go into the Topology, Click on Main topology, select the Region and then RNC, right click on RNC and click on Maintainance client. Confidential 7
© Nokia Siemens Networks
M2000: To fetch the Dump// WebLMT// File Manager
Browse the path, select the file, click on the download tab and give the path. Confidential 8 © Nokia Siemens Networks
M2000: To activate Measurement counters
Confidential 9 © Nokia Siemens Networks
M2000: To activate Measurement counters 1. Go into the performance and click on Measurement management. 2. Select the appropriate Function Subset and NE. 3. In Measurement status, we can check the active counters 4. In Measurement settings, Select the appropriate Function set and Function subset, find the counter and activate it (√) for either 15min or 60 min or 24 hrs 5. Click Apply to activate the Counters
Confidential 10 © Nokia Siemens Networks
M2000: To activate Measurement counters// Measurement Status
In Measurement status, we can check the active counters Confidential 11 © Nokia Siemens Networks
M2000: To activate Measurement counters// Measurement Settings
In Measurement settings, Select the appropriate Function set and Function subset, find the counter and activate it (√) for either 15min or 60 min or 24 hrs. Click Apply to activate the Counters. Confidential 12 © Nokia Siemens Networks
M2000: To Modify the Parameters
Confidential 13 © Nokia Siemens Networks
M2000: To Modify the Parameters It is mandatory to know the commands to change the parameters. Different parameters belongs to different classes and each class has its own syntax. For example: If need to modify the CPICH power. 1) Lst UPCPICH– to check the existing CPICH power 2) Mod UCELL– to modify the CPICH Tx power(note: the modified power should be in the max and min limit of CPICH power. To modify the max and min limit use the command Mod UPCPICH.
Confidential 14 © Nokia Siemens Networks
M2000: To Modify the Parameters // e.g. Modify CPICH power
LST UPCPICH
MOD UCELL
Confidential 15 © Nokia Siemens Networks
M2000: To define Custom KPI’s
Confidential 16 © Nokia Siemens Networks
M2000: To define Custom KPI’s 1. Customized KPI’s can be created using M2000. Click on Performance and select Custom Counter management. 2. In the Function subset, select the BSC or RNC. 3. To create a new report, click on the tab Add. 4. Give some name for custom counter, Units, Select the Function set and Function subset. (note: Pay attention to select Function set and Function subset, we can only find the counter in related Function set and Function subset) 5. From the Function set, select the counters, use the arithmetic operations available to add, subtract, multiply.. In between the counters. 6. Click Apply and then ok Note: Since we are not using M2000 in VHA-AUS project for performance management this may not require. “GP” of mathematical operator in the window is measurement period, its unit is minute; For RNC KPI, we can only select counters of RNC wise; for cell KPI, we can only select counter of cell wise, M2000 can’t support gather function.
Confidential 17 © Nokia Siemens Networks
M2000: To define Custom KPI’s// Adding a new KPI// e.g. for SHO attempts
Some Name for identification
Units
Final formula can be seen in this window.
Confidential 18 © Nokia Siemens Networks
M2000: To define KPI report template
Confidential 19 © Nokia Siemens Networks
M2000: To define KPI report template 1. Go into the performance select the query result 2. Select New query 3. Select same “Function Subset” in directory tree of new window as that of defined KPI formula. We can only select unique “Function Subset” in one report, so define all counters of a report in the same Function Subset. Then select measurement object in the window of “Object Settings. 4. In the object settings, Select the Objects (RNC, BSC or Cell) 5. In the Counters settings, select the counters that need to be fetched.(the counters can be system counters or the customized one) 6. In time conditions, select the time for which the KPI need to be fetched. 7. Click on Save template and save it with appropriate name.
Confidential 20 © Nokia Siemens Networks
M2000: To define KPI report template // Adding a new KPI template
There is some issue with window size when new query is selected. So no more snaps can be attached for this class Confidential 21 © Nokia Siemens Networks
M2000: To fetch KPI reports
Confidential 22 © Nokia Siemens Networks
M2000: To fetch KPI reports 1. Go into the performance select the query result 2. Select the customized KPI template, right click, select the Query results and then click on any of the time lines specified. (note: if the report is required for some other measurement period select Specific) 3. Once the report is generated click on save tab and save it to local PC.
Note: For VHA AUS there is some restriction in M2000 for fetching KPIs. PRS is preferred for performance management.
Confidential 23 © Nokia Siemens Networks
M2000: To fetch KPI reports
Confidential 24 © Nokia Siemens Networks
M2000: To fetch Alarms(both History and Active)
Confidential 25 © Nokia Siemens Networks
M2000: To fetch Alarms Active alarms 1. Go into the monitor select the Browse alarm list 2. In the Basic settings, select the Severity, status and type 3. In Alarm source, select the NE type and click ok. History Alarms: 1. Go into the monitor and select the Query Alarm logs. 2. Follow the same procedure as mentioned in the Active alarms. Mention the history period for which the alarms are fetched.
Confidential 26 © Nokia Siemens Networks
M2000: To fetch Active Alarms
Confidential 27 © Nokia Siemens Networks
M2000: To fetch Active Alarms
Select the Object, i.e. RNC or NodeB or Cell. Confidential 28 © Nokia Siemens Networks
End