ProSheet 2.2 06-06 Design software for sheet pile retaining walls
1
Introduction ProSheet 2.2 Design program developped in collaboration with the Sheet Piling department of ARCELOR COMMERCIAL RPS: • allows quick dimensionning of steel sheet pile retaining walls • designed for simple structures and pre-dimensionning (refer to chapter “ possibilities “)
• geotechnical knowledge / backround required (definition of soil characteristics / calculation of retaining walls)
The results produced by this method have to be checked carefully by the user in order to make sure that modelization of the soil-structure interaction is accurate enough. 2
Introduction (...) Calculation method: • Fixed earth support according theory of Dr. Blum • Limit earth pressure - earth resistance Ka / Kp (Caquot / Kerisel)
Three static systems are possible: • Cantilever • Free earth support with one layer of anchor or struts • Fixed earth support with one layer of anchor or struts (Blum)
3
General informations • Installation and configuration – Two languages are possible (F or GB) ° separate directories if both versions are installed – Configuration: decimal symbol = " . " (see also "Read-me" / evtl. use "French-Switzerland") – Metric or imperial units • Convention (see also "Help"-File) – Levels º positive downwards, refered to level ± 0.00 º negative upwards – Wall friction angle (to be introduced manually) º Earth pressure : δa = positive º Earth resistance : δp = negative 4
Possibilities • Continuous sheet pile wall design with: – 1 retaining level (anchorage or struting) – rear anchor wall – simulation of construction stages NOT possible Be careful: construction stage could guide the design ! – catalogues of ARCELOR sections ° AU, PU, AZ, Coldformed OSP ° not included: HZ-AZ combined wall system • Various options – uniforme surcharge load of type Caquot – lineare surcharge load of type Boussinesq – concentrated forces – additional pressures on the wall
5
Dimensionning of main wall Three static systems are possible
Cantilever wall Hrecom.: 5 à 6 m Mbend Ê / fmax Ê length Ê
Anchored / strutted wall free earth support Mbend. Ê / R Ê minimum pile length 6
Anchored / strutted wall fixed earth support Mbend. Ì / R Ì longer pile than free meth.
Dimensionning of anchor wall Two static systems are possible - free earth support